Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

Size: px
Start display at page:

Download "Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased"

Transcription

1 TELEDYNE Series 3300 Unaffected by hydrocarbons, H2, or CO2 Easy to handle, inexpensive, and easy to replace Can apply to ppb, ppm, and percent ranges Trace & Percent Oxygen Analyzers Fuel Cell Zirconium Oxide Paramagnetic Sensing Technologies The 3300 series of low cost, microprocessorbased instruments are specifically designed to satisfy industry s need for a simple yet highly reliable process analyzer. These unit offer excellent accuracy, ease of use, high reliability, low maintenance and a variety of standard features usually found on more expensive instruments. One Platform, Multiple Configurations The 3300 series is a cost-effective solution to many process applications. With three different sensing technologies to choose from and multiple design configurations, a customized unit for a given application is easily secured. Sensing ranges are varied based on the oxygen sensor and technology used. All units come with auto ranging capability and a 0-25% calibration range. Fully adjustable high or low concentration alarms provide the versatility to satisfy nearly any requirement. Sensing Technologies The 3300 Series is available with three sensing technologies, each with their own benefits. Micro-fuel Cell T, 3300P Disposable, no maintenance sensor design Specific to oxygen Linear from 0-100% O2 Absolute Zero (no O2, no output); single point calibration only Zirconium Oxide Z Quick response time Long life / service on clean, non-corrosive streams No shelf life concerns Can be applied on a wide variety of applications Paramagnetic M Long life / service in clean gas streams High accuracy Can be applied on corrosive, high temperature applications Fast response times (even on CO2 streams) Outputs for Data Transmission A standard 0-10 VDC output provides range identification, while the oxygen concentration is output through 4-20 madc negative ground and 0-10 VDC negative ground signals. An optional unidirectional RS-232 serial interface can be incorporated to relay information to a host computer for remote monitoring, making information and analysis results as close as a personal computer. Configurations (A) - 19 rack mount (B) - Wall mount enclosure Advantages Customer selectable ranges Auto ranging capabilities Fully adjustable high or low alarm setpoints with corresponding relay contacts Digital interface allows monitoring from a remote station Sensor failure alarm Options RS-232 serial interface for remote monitoring Built for reliability and performance

2 Series 3300 trace / percent Oxygen AnalyzerS series 3300 Trace / percent oxygen analyzers SPECIFICATIONS Ranges: 3300T 3300P 3300M 3300Z Two ranges with auto-ranging capability; field configurable between 0-10 ppm and 0-10,000 ppm 0-1 to 0-25% oxygen (0-3% and 0-10% default) Two ranges with auto-ranging capability; field configurable between 0-3% and 0-10% 0-10 ppm to 0-100% (user defined ranges) Calibration range: 0 to 25% O2 0 to 25% O2 0 to 25% O2 0 to 25% O2 Display: 4 digit LED 4 digit LED 4 digit LED 4 digit LED Accuracy: ±2% FS at constant temp, ±5% FS over operating temperature (once temperature equilibrium is reached). Higher accuracy is available for special configurations. Response time: 90% in less than 45 seconds at 77 F (25 C) 90% in less than 10 seconds at 77 F (25 C) 90% in less than 6 seconds at 77 F (25 C) Operating temp: F (0-50 C); special temperature ranges available Signal output: For oxygen concentration: 4-20 madc negative ground and 0-10 VDC signals For range identification: 0-10 VDC signal Range ID: 0-10 VDC 0-10 VDC 0-10 VDC 0-10 VDC Alarm output: Two fully adjustable high or low alarms; one sensor fail relay (all alarms are fail-safe) Power Universal AC VAC, Hz requirements: Sampling system: Various options available. Contact factory. Connections: 1/4 inch or 6mm -- user specified Oxygen sensor: Micro-fuel Cell Micro-fuel Cell; Class I-22 Paramagnetic Zirconium oxide TELEDYNE A Teledyne Technologies Company Chestnut Street City of Industry, California 91748, USA Warranty Instrument is warranted for 1 year against defects in material or workmanship NOTE: Specifications and features will vary with application. The above are established and validated during design, but are not to be construed as test criteria for every product. All specifications and features are subject to change without notice. TEL: or FAX: ask_tai@teledyne.com Teledyne Analytical Instruments, A Teledyne Technologies Company. All rights reserved. Printed in the USA. 09/05LD

3 Teledyne Analytical Instruments Model 3000ZA-XL The first amperometric based zirconium oxide analyzer for trace applications The sensor has been designed for enhanced performance on ranges from 0-5 ppm to ppm. By focusing on this niche area of interest, the 3000ZA-XL provides the user with highly stable, drift-free performance. Zirconium Oxide Trace Oxygen Analyzer Teledyne manufactures a variety of oxygen analyzers utilizing state-of-the-art technologies to monitor oxygen in virtually all industrial bulk gases supplied by the air separation community. To compliment our electrochemical fuel cell and paramagnetic oxygen products, Teledyne has developed a zirconium oxide-based (ZrO2) trace oxygen analyzer, the 3000ZA-XL, which can be readily applied on inert, H2 / HC-free, gas streams. The unique, miniature, amperometric-based ZrO2 sensor provides the operator with unrivaled repeatability, responsiveness and stability. Proven Analyzer Platform By integrating Teledyne s amperometric ZrO2 oxygen sensor with our field-proven Series 3000 platform, the user achieves highly reliable control of their process. The 3000ZA-XL comes standard with (3) user programmable ranges, user selectable fixed or automatic range change capabilities, range ID contacts, two concentration output signals (current and voltage), a RS-232C bi-directional serial interface, two configurable concentration alarms, a system failure alarm, and user programmable auto-calibration capabilities. Designed for flush panel mounting, two units can be mounted sideby-side in a panel space-saving 19 rack arrangement. Sensing Technology The 3000ZA-XL utilizes a non-depleting amperometric zirconium oxide sensor. This miniature ZrO2 sensor generates a current signal linearly proportional to the part-per-million levels of oxygen present in the sample gas. The sensor also operates at a favorably lower operating temperature than conventional ZrO2 sensors providing a longer expected life of 5-plus years due to less thermal stress. In addition, Teledyne s amperometric ZrO2 sensor requires no reference gas supply, reducing installation and running costs as well as eliminating any inaccuracies associated with possible reference gas composition variances. Ideal for Unmanned Plant Operations Because the sensor has no reference gas requirements, operates on a non-depleting basis, and can easily be fitted with Teledyne s uniquely designed, electronically-driven, miniature integral auto-calibration valve manifold, it is an ideal choice for unmanned plant requirements. Key Features Highly flexible, field-proven Series 3000 platform Programmable Auto-Calibration capabilities User selectable ranges Helium leak checked sample handling system High sensitivity of 25 ppb or better Advantages No reference gas requirements = lower operating costs Long life, maintenance-free, non-depleting ZrO2 sensor design Highly stable, drift-free performance Low sensor replacement cost Applications Air liquefaction Inert gas blanketing Glove box monitoring Bulk gas purity certification Semiconductor manufacturing Note: The 3000ZA-XL should only be applied on inert sample gas streams which are ideally free of combustible gas impurities. For streams that may have trace levels of H2, CO, or hydrocarbons present, please consult with Teledyne in advance to address application feasibility considerations. Built for reliability and performance

4 3000ZA-XL ZIRCONIUM Oxide trace Oxygen Analyzer Standard Features Three user-selectable ranges Signal output: 0-1 VDC & 4-20 madc Programmable Auto Ranging Range ID contacts (Quantity 4). Form A normally open contacts, 3A resistive Two fully-adjustable concentration alarm points with programmable relay function. Form C contacts, 3A resistive Programmable auto cal / zero. Form A normally open contact relay signals Remotely initiated cal / zero via customer supplied 24 VDC signal Self diagnostics with Form C failure alarm contacts Full duplex RS-232 communication link Five digit oxygen concentration LED display Backlit 2 x 20 line alphanumeric liquid crystal display for set up and diagnostics 316 stainless steel sampling system Sample flow indicator Universal power supply: VAC Hz Specifications Ranges: Accuracy: Sensitivity: Response: Operating temp: Cross sensitivity: 3 ranges customer selectable (from 0-5 ppm to 0-25%)(optional low and optional high ranges available) ± 1% of FS at a constant temperature 0.5% of full scale 90% of FS at 77 F (25 C) < 30 seconds 32 to 122 F (0 to 50 C) Less than 0.5 ppm O2 with 5 ppm H2, 5 ppm CH4, or 5 ppm CO Signal output: Analytical measurement VDC, and 4-20 madc (isolated) Max. load impedance: Analysis display: Data lines: 4-20 ma isolated output 1000 ohms 5 digit red LED, 3/5 high numerals Bi-directional RS-232C serial interface Power requirements: Universal AC input ranges - 85 to 230 VAC, 50 / 60 Hz Max. power consumption: Oxygen sensor: Sample connections: Wetted parts: Area classifications: Mounting: Dimensions: 20 VA Zirconium oxide, amperometric type User specified 1/4 or 6 mm fittings Stainless steel and nylon General purpose Flush panel mount 8.70 W x 6.96 H x 12.2 D (case) W x 7.46 H (panel) Options -C Auto cal / zero with integrally mounted control valves -K 19 rack mount with either one or two control units TELEDYNE A Teledyne Technologies Company Chestnut Street City of Industry, California 91748, USA Warranty Instrument is warranted for 1 year against defects in material or workmanship NOTE: Specifications and features will vary with application. The above are established and validated during design, but are not to be construed as test criteria for every product. All specifications and features are subject to change without notice. TEL: or FAX: ask_tai@teledyne.com Teledyne Analytical Instruments, A Teledyne Technologies Company. All rights reserved. Printed in the USA. 01/06LD

5 Teledyne Analytical Instruments Models 3190 and 3290 Two programmable failsafe concentration alarms (one high and one low setpoint) provide the versatility to satisfy nearly any requirement. And because it s a Teledyne product, you can rely on many years of quality service. Trace & Percent Oxygen Analyzers Fuel Cell or Zirconium Oxide Sensors Good things come in small packages, and Teledyne s 3190 Trace or 3290 Percent Oxygen Analyzer proves it. These microprocessor based units offer high accuracy, easy use, and all the standard features demanded by the end-user in a compact, budget priced design. Membrane command switches and a large, four digit LED display make setup and operation clear and quick. For the latest technology, Teledyne quality, and an unbeatable value, the 3190 or 3290 provides a pocket-sized solution. Field-Configurable Range Options Depending on the application, these units can be configured to utilize one of Teledyne s patented, Micro-fuel Cell sensors or zirconium oxide sensors, assuring the highest accuracy. With a long expected sensor life, the 3190 or 3290 is as inexpensive to maintain as it is to purchase. Teledyne has even provided a sensor failure alarm, taking the worry and work out of the end-user s hands. Two ranges are field configurable on Model 3190 at 0-10 ppm and ppm with a 0-25% calibration range. Optional ranges can be set between 10 ppm and 10,000 ppm. The 3290 ranges are field configurable between 1% and 25% oxygen with 0-25% oxygen calibration. An optional full scale range is available up to 100%. Autoranging is standard on both models. Outputs For Data A standard 0-10 VDC output provides range identification, while the oxygen concentration is output through 4-20 madc negative ground and 0-10 VDC negative ground signals. An optional unidirectional RS-232 serial interface is incorporated to relay information to a host computer for remote monitoring of all functions. Configuration information and analysis results are as close as your personal computer. Advantages AutoRanging capabilities One high and one low alarm setpoint with corresponding relay contacts Sensor failure alarm Standard Features Two field configurable ranges plus cal range (0-25%) Signal output: 0-10 VDC for range identification Analytical output: 4-20 madc negative ground and 0-10 VDC signals Universal AC power supply (Optional configuration available) Optional Configurations - Power requirement: VDC - Zirconium oxide sensor Applications Wave solder reflow ovens Glove box manufacturers Nitrogen membrane skids PSA skids Helium recovery systems Diving applications Clean air systems for medical applications Built for reliability and performance

6 3190 / 3290 trace / percent Oxygen AnalyzerS 3190 Trace 3290 Percent Ranges: 0-10 ppm and ppm and 0-25% calibration range (nominal) (user selectable percent ranges) (user selectable ranges can be set between 10 ppm and10,000 ppm) 0-3% and 0-10% oxygen (standard ranges) and 0-25% calibration range (nominal) (user selectable percent ranges) (user selectable ranges can be set between 1% and 25% O2) An optional 0-100% range is available. Display: LED LED Accuracy: ±1% of full scale at constant temperature ±2% of full scale at constant temperature; ±5% of full scale over operating temperature (once temperature equilibrium is reached; at 3% and higher user-defined ranges) Response time: 90% in less than 45 seconds at 25 C for fuel 90% in less than 10 seconds at 25 C cell, faster with a zirconium oxide sensor System operating temp: 0-50 C 0-50 C Signal output: 4-20 ma and 0-10 VDC negative ground, non-isolated Range identification: 0-10 VDC 0-10 VDC Alarm output: One high alarm relay, adjustable; One low alarm relay, adjustable; One sensor calibration fail relay (all alarms are failsafe) System power requirements: VDC or 100V-240 VAC; Hz, user specified Dimensions Panel mount: 2.81 H x 6 W x 2.87 D (71.4 x x 72.9 mm) Oxygen sensor: Class B-2 (for ranges lower than ppm) Class E-2 Optional: - Class A-2C for CO2 backgrounds - Zirconium oxide Optional: - Class A-5 for CO2 backgrounds - Zirconium oxide SP76 Compliant Oxygen Sensor Teledyne offers an SP76 compliant oxygen sensor for trace and percent ranges. SP76 is the Instrument Society of America s standard for sampling system components, which brings the following advantages: Substantially reduced size -- as compared to the alternative which requires discrete tubing cut and connected through fittings of various components, i.e. sensors, pressure regulators, valves, etc. A building block, plug-and-play approach that makes even the most inexperienced assembler or designer an immediate expert TELEDYNE A Teledyne Technologies Company Chestnut Street City of Industry, California 91748, USA Warranty Instrument is warranted for 1 year against defects in material or workmanship NOTE: Specifications and features will vary with application. The above are established and validated during design, but are not to be construed as test criteria for every product. All specifications and features are subject to change without notice. TEL: or FAX: ask_tai@teledyne.com Teledyne Analytical Instruments, A Teledyne Technologies Company. All rights reserved. Printed in the USA. 1/06LD

Teledyne s Series IR7000 features excellent linearity and stability.

Teledyne s Series IR7000 features excellent linearity and stability. TELEDYNE Series IR7000 Non-dispersive Infrared Gas Analyzers Teledyne s Series IR7000 features excellent linearity and stability. Using advanced microprocessor technology, these instruments make monitoring

More information

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES PROCESS ANALYZERS DF-340E The DF-340E is a Coulometric sensor based oxygen analyzer suitable for outdoor installation and designed to measure trace oxygen and percent level in pure and multigas backgrounds.

More information

OPERATING INSTRUCTIONS FOR

OPERATING INSTRUCTIONS FOR OPERATING INSTRUCTIONS FOR Model 3190Z Trace Oxygen Analyzer P/N M3190Z 6/09/09 DANGER Toxic gases and or flammable liquids may be present in this monitoring system. Personal protective equipment may be

More information

Series 9000 Total Hydrocarbon Analyzer

Series 9000 Total Hydrocarbon Analyzer Series 9000 Total Hydrocarbon Analyzer Analyzer The Baseline Series 9000 is the candidate of choice whenever accurate, reliable total hydrocarbon analysis is required. The Series 9000 analyzer provides

More information

INSTRUCTION, OPERATING, AND MAINTENANCE MANUAL FOR MODEL Special Version with Modifications for Automatic Background Gas Switching DANGER

INSTRUCTION, OPERATING, AND MAINTENANCE MANUAL FOR MODEL Special Version with Modifications for Automatic Background Gas Switching DANGER Total Hydrocarbon Analyzer INSTRUCTION, OPERATING, AND MAINTENANCE MANUAL FOR MODEL 4020 Special Version with Modifications for Automatic Background Gas Switching P/N M81965 4/05/2010 Rev 6 DANGER Toxic

More information

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm Oxygen Deficiency Monitor and Oxygen Analyzers Oxygen Sensors for 0-25% and 0-1000ppm ABOUT PUREAIRE MONITORING SYSTEMS PureAire is an experienced safety gas detection manufacturer providing long lasting

More information

Oxygen Analyzer Manual

Oxygen Analyzer Manual Oxygen Analyzer Manual AMI Model 70 AMI, Huntington Beach Contents Preface 1 The AMI story 1 Caution 1 Address 1 Model 70 Oxygen Analyzer 2 Introduction 2 Features: 2 Oxygen sensor: 3 Sensor Warranty:

More information

Toxic Gas Detection. Model F12. Toxic Gas Detection

Toxic Gas Detection. Model F12. Toxic Gas Detection Toxic Gas Detection Model F12 Toxic Gas Detection Smart Sensor Technology The Series F12 Gas Transmitter is an Intrinsically Safe (IS) version of our explosion-proof D12 transmitter. In its standard form,

More information

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes Xi Advanced Electronics for Zirconium Oxide Oxygen Probes Excellent accuracy Large backlit display and keypad NEMA 4X enclosure Works with Westinghouse/Rosemount, and most competitive ZrO probes HART communications

More information

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes Xi Advanced Electronics for Zirconium Oxide Oxygen Probes Excellent accuracy Large backlit display and keypad NEMA 4X enclosure Works with Westinghouse/Rosemount, and most competitive ZrO 2 probes HART

More information

Series 5000 Hydrazine Analyzer Model 60002

Series 5000 Hydrazine Analyzer Model 60002 Series 5000 Hydrazine Analyzer Model 60002 T he patented* Series 5000 Hydrazine Analyzer is a continuous-reading instrument using the p-dimethylaminobenzaldehyde method of analysis for colorimetric measurement

More information

A New Standard of Excellence

A New Standard of Excellence A New Standard of Excellence PREVENTION IS SO EASY... LIVING THROUGH A DISASTER IS NOT The reliable identification of low combustion oxygen in a fired heater or boiler has always been critical to the effectiveness

More information

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels. Gas Chromatograph Continuous Analysis of Ultra High Purity Argon to ppb levels Features Following on from the success of the AGC Series 100 Argon GC, AGC Instruments introduces the new NovaCHROM 2000 GC.

More information

Model D12-IR. Digital Gas Transmitter...

Model D12-IR. Digital Gas Transmitter... Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact

More information

HFID Heated Total Hydrocarbon Analyzer Module

HFID Heated Total Hydrocarbon Analyzer Module Product Data Sheet PDS 103-685.A01 October, 2003 NGA 2000 HFID Heated Total Hydrocarbon Analyzer Module Heated analyzer designed to operate from 200 F to 400 F Eliminates loss of hydrocarbons due to condensation

More information

Process Gas Chromatograph

Process Gas Chromatograph A I T Applied Instrument Technologies FXi Series5 PRODUCT SPECIFICATIONS Process Gas Chromatograph PSS FXI-S5 The FXi Series5 Process Gas Chromatograph (PGC) continuously analyzes, measures, and reports

More information

Dew-Point Transmitters and Instruments

Dew-Point Transmitters and Instruments Dew-Point Transmitters and Instruments Reliable moisture measurement for critical process control Moisture Measurement and Analysis Michell Instruments sensors provide accurate and reliable moisture measurement

More information

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards. Touchpoint 1 The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards. Touchpoint 1 controller User Friendly Self-contained, wall mounted enclosure Ultra-clear

More information

Model OEM-2 INSTRUCTIONS FOR USE

Model OEM-2 INSTRUCTIONS FOR USE ECO SENSORS, INC. 3-03.2 OEM OZONE CONTROLLER Model OEM-2 INSTRUCTIONS FOR USE GENERAL The model OEM-2 is a system to control ozone generators and alarms based on an adjustable ozone concentration set

More information

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display. Sheet No. 1 of 4 monitor/analyzer with alarm and Graphical Display. Sheet No. 2 of 4 It specially designed to analyze any gas of your choice, its automatic operation, accurate measurement and crystal clear

More information

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor... Improve Performance and Reduce Maintenance Costs Model Q45D Dissolved Oxygen Monitor... Why Throw Away Money? Why Throw Away Money? ATI s Model Q45D Dissolved Oxygen monitor is designed to provide reliable

More information

QAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR

QAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR QAS-10000 SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR INSTALLATION, OPERATION AND MAINTENANCE MANUAL QUATROSENSE ENVIRONMENTAL LTD. 5935 OTTAWA STREET, PO BOX 749, RICHMOND, ONTARIO, CANADA. K0A

More information

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry The «Modular Rack Gas Generators» Solution Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry With Unique Remote Control Monitoring

More information

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS. SERVOTOUGH FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS Flexible Can be used in hazard rated locations including Zone

More information

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards Touchpoint 4 The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards Touchpoint 4 Controller User Friendly Self-contained, wall mounted enclosure

More information

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu) PART 1 - GENERAL A. RELATED DOCUMENTS SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu) Federal, State, and local requirements as applicable. Attached Permit Attached drawings B. SUMMARY 1. Provide

More information

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications 70-82-03-48 January 2003 Overview The DirectLine DL424/425 Sensor Modules are part of a family of products developed

More information

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies. GE Sensing & Inspection Technologies Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in

More information

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features: Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low cost package. Patented

More information

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies. GE Sensing & Inspection Technologies Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in

More information

OPERATING INSTRUCTIONS FOR

OPERATING INSTRUCTIONS FOR Trace Oxygen Analyzer OPERATING INSTRUCTIONS FOR MODEL OT-3 Trace Oxygen Analyzer P/N M74173 10/28/2001 ECO# DANGER Toxic gases and or flammable liquids may be present in this monitoring system. Personal

More information

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314) Mass Sensors, Inc. 1350 Baur Blvd, St. Louis, MO 63132 (314) 997-5779 www.mass-sensors.com Innovations in chemical microsensors Profile Mass Sensors is a development stage high-tech company operating in

More information

PUV, PIR and PFO Series BROCHURE

PUV, PIR and PFO Series BROCHURE PUV, PIR and PFO Series BROCHURE JUNHO 2013 ABB Multiwave TM process photometers PUV3402, PIR3502 and PFO3372 Measure vapor and liquid samples in IR, NIR, UV and VIS regions Process photometers PUV3402,

More information

Autocalibration Systems for In Situ Oxygen Analyzers

Autocalibration Systems for In Situ Oxygen Analyzers Product Data Sheet CMB_PDS_340AC_AutoCal Autocalibration Systems for In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging from one to four oxygen analyzers Can be easily

More information

vacuum FLOW support excellence experience

vacuum FLOW support excellence experience How May We Help You? vacuum vacuum flow FLOW support support excellence manufacturing excellence experience application experience flow meters and controllers meeting your requirements 200 Series general

More information

OPERATING INSTRUCTIONS. Model 3010MB. Bulkhead Mount Control Unit, PN D Bulkhead Mount Analysis Unit, PN D DANGER

OPERATING INSTRUCTIONS. Model 3010MB. Bulkhead Mount Control Unit, PN D Bulkhead Mount Analysis Unit, PN D DANGER Percent Paramagnetic Oxygen Analyzer OPERATING INSTRUCTIONS Model 3010MB Percent Paramagnetic Oxygen Analyzer Bulkhead Mount Control Unit, PN D-71385 Bulkhead Mount Analysis Unit, PN D-71394 DANGER HIGHLY

More information

931D Style B Process Gas Chromatograph

931D Style B Process Gas Chromatograph Product Specifications PSS 6-4N1 D 931D Style B Process Gas Chromatograph The new 931D Style B Process Gas Chromatograph continuously analyzes, measures and reports the concentration of components in process

More information

Industrial Grade Gas Detection Detecting The Difference

Industrial Grade Gas Detection Detecting The Difference detcon inc. Industrial Grade Gas Detection Detecting The Difference PO Box 8067 The Woodlands, TX 77387 888-367-4286 (toll free) 713-559-9200 281-292-2860 (fax) sales@detcon.com Catalog #CB-0409 www.detcon.com

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable

More information

OX100/OX102. Limiting-current type Oxygen Analyzer. Bulletin 11M10A01-03E

OX100/OX102. Limiting-current type Oxygen Analyzer. Bulletin 11M10A01-03E / Oxygen Analyzer Bulletin MA-3E A Compact Environmental Oxygen Anal yzer with the usual Yokogawa reliability MODEL MODEL Alarm Calibration keys holder: 7 mm (* ) dia. or G3/8 Plastic sensor holder (Specify

More information

Mercury Vapor Monitor VM-3000

Mercury Vapor Monitor VM-3000 Member of the envea Group Mercury Vapor Monitor VM-3000 Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Proven reliable detection method: UV absorption (CVAAS)

More information

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview Micro SCM Streaming Current Monitor A Watts Water Technologies Company Instrument Overview The instrument consists of the Analyzer and the SCM sensor. Analyzer The Analyzer The monitor has a built in graphic

More information

GPR-2600 Oxygen Analyzer

GPR-2600 Oxygen Analyzer Technical Specifications * Accuracy: Analysis: Application: Approvals: < 2% of FS range under constant conditions 0-1%, 0-5%, 0-10%, 0-25% FS ranges Auto-ranging or manual lock on a single range Oxygen

More information

OX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102. Bulletin 11M10A01-03E

OX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102.  Bulletin 11M10A01-03E Limiting-current type Oxygen Analyzer OX00, OX02 OX00, OX02 Limiting-current type Oxygen Analyzer One Instrument measures 00 ppm to 25% Oxygen Simple "One Touch" Calibration Self Diagnostics Assure High

More information

Trace Moisture Analyzer for Inert, Passive,Toxic, and Corrosive Gases

Trace Moisture Analyzer for Inert, Passive,Toxic, and Corrosive Gases Trace Moisture Analyzer for Inert, Passive,Toxic, and Corrosive Gases THE TIGER S TALE Tiger Optics is proud to announce a significant advance in moisture measurement for UHP inert, toxic, and corrosive

More information

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications Data Sheet Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications Ideal for small gas/oil fired boilers Cost effective solution for OEM outlets with a quick return on end-user investment Continuous

More information

Analog Room Pressure Monitor RPC Series

Analog Room Pressure Monitor RPC Series Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the

More information

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL GASGUARD Cl 2 Chlorine Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual 2 Table of Contents GasGuard Cl 2 Operating and Instruction Manual General description. 4 Installation..

More information

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM 2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40

More information

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011 MICHELL GROUP Advanced Industrial Hygrometry and Process Instrumentation Company Profile, 2011 Who is the Michell Group? Leading in the world of solutions for humidity and gas analysers More than 30 years

More information

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR INSTALLATION OPERATION AND MAINTENANCE MANUAL QUATROSENSE ENVIRONMENTAL LTD. 5935 OTTAWA STREET, PO BOX 749 RICHMOND, ONTARIO CANADA

More information

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm Oxygen Deficiency Monitor and Oxygen Analyzers Oxygen Sensors for 0-25% and 0-1000ppm Who is PureAire Monitoring Systems We are an industry leader in gas detection. Our mission at PureAire is simple. Keep

More information

SIL 2. Ultima X Series Gas Monitors CERTIFIED

SIL 2. Ultima X Series Gas Monitors CERTIFIED Ultima X Series Gas Monitors 5 Now with SIL 2 CERTIFIED Products Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection

More information

Airflow Sensors Line Guide

Airflow Sensors Line Guide Line Guide Go with the flow of engineering leadership. All airflow sensors operate on heat transfer flow and differential pressure. But Honeywell Sensing and Control (S&C) offers advanced chip design,

More information

QAS-101 SERIES SINGLE CHANNEL CONTROLLERS

QAS-101 SERIES SINGLE CHANNEL CONTROLLERS QAS-101 SERIES SINGLE CHANNEL CONTROLLERS INSTALLATION OPERATION AND MAINTENANCE MANUAL QUATROSENSE ENVIRONMENTAL LTD. 5935 OTTAWA STREET, PO BOX 749, RICHMOND, ONTARIO, CANADA. K0A 2Z0 PHONE: (613) 838-4005

More information

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS A Worldwide Manufacturer of Process Analyzers and Instrumentation RELIABILITY EXPERIENCE SOLUTIONS AMETEK Process Instruments is a worldwide

More information

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL GASGUARD NH 3 Ammonia Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual 2 Table of Contents GasGuard NH 3 Operating and Instruction Manual General description. 4 Installation.. 4

More information

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics 4000TOC Sensor THORNTON Leading Pure Water Analytics 4000TOC Sensor Fast, continuous measurements No reagents or chemicals needed No moving parts Meets USP 643, 645,Ch P, EP 2.2.44, and JP requirements

More information

Low Temperature Zirconia Oxygen Analyzer

Low Temperature Zirconia Oxygen Analyzer Data Sheet SS/ZDT FG Issue 10 Low Temperature Zirconia Oxygen Analyzer ZDT FG Environmental certification MCERTS SIRA certificate MC99000 1/00 User-friendly language options selectable system alarms comprehensive

More information

Mark 25 Ultrapure Water Conductivity Analyzer

Mark 25 Ultrapure Water Conductivity Analyzer Martek Instruments, Inc. Mark 25 Ultrapure Water Conductivity Analyzer Instruction Manual WARRANTY POLICY Unless otherwise stated, MARTEK INSTRUMENTS, INC. warrants this equipment to be free from defects

More information

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors Ultima X Series Gas Monitors Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection methods. HART Protocol is now

More information

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ] ULTIMA XL/XT Series Gas Monitors [ Ultimate Features Extreme Design ] Cost effective fixed installation gas monitors with HART Field Communications Protocol. Single-sensor units use catalytic, electrochemical

More information

MSA Fixed Gas & Flame Detection for the Automotive Industry

MSA Fixed Gas & Flame Detection for the Automotive Industry MSA Fixed Gas & Flame Detection for the Automotive Industry A Passion for Safety Automotive facilities may be comprised of research and development laboratories, and engine testing and environmental chambers.

More information

Transmitter OCX 4400 THE LATEST BREAKTHROUGH FOR COMBUSTION FLUE GAS ANALYSIS. Product Data Sheet PDS A01 February, 2001

Transmitter OCX 4400 THE LATEST BREAKTHROUGH FOR COMBUSTION FLUE GAS ANALYSIS. Product Data Sheet PDS A01 February, 2001 OCX 4400 Product Data Sheet PDS 106-440.A01 February, 2001 Oxygen/Combustibles Transmitter Both oxygen and combustibles measurements in a single instrument Unique architecture - electronics mounted with

More information

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER ISO-14001 ISO-9001 SPECIFICATION SHEET SILICA ANALYZER Model: SLC-1605 (for very low concentration) SLC-1615 (for low concentration) SLC-1625 (for high concentration) This equipment is used for high accuracy

More information

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES USER INSTRUCTIONS FOR THE CHEMGARD INFRARED GAS MONITOR SERIES To completely customize the specification to your exact application, modification to the

More information

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1 Project Name Page 1 PART 1 GENERAL 1.1 Section includes: A. A modular single or dual channel controller that works with analog sensor modules and/or digital sensors. 1.2 Measurement Procedures A. Microprocessor-based

More information

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual GG-CO-EXP CARBON MONOXIDE SENSOR Installation and Operation Manual 2 GG-CO-EXP Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by

More information

White paper on the Dielectric Barrier Discharge Detectors. Introduction:

White paper on the Dielectric Barrier Discharge Detectors. Introduction: White paper on the Dielectric Barrier Discharge Detectors. Introduction: This paper is a discussion of the dielectric barrier discharge detector. As such, it is intended to provide insight into the operating

More information

PureAire Combo O 2 / CO 2 Monitor

PureAire Combo O 2 / CO 2 Monitor PureAire Combo O 2 / CO 2 Monitor Instruction Manual PureAire Monitoring Systems, Inc. 557 Capital Drive Lake Zurich, Illinois 60047 Phone: 847-726-6000 Fax: 847-726-6051 Toll-Free: 888-788-8050 pureairemonitoring.com

More information

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller Unipoint ontroller The Unipoint, a simple DIN rail mounted controller Unipoint DIN ontroller Typical Applications Small and medium integrated systems ustom control cabinets and panels Unmanned equipment

More information

Oxygen Sensing Solutions

Oxygen Sensing Solutions Oxy020608 Issue H Oxygen Sensor Catalogue SST SENSING LTD Oxygen Sensing Solutions 1 Oxygen Sensing SST Sensing are experts in the field of oxygen and fluid measurement. We have a comprehensive range of

More information

INSTRUCTION, OPERATING AND MAINTENANCE MANUAL FOR MODEL

INSTRUCTION, OPERATING AND MAINTENANCE MANUAL FOR MODEL INSTRUCTION, OPERATING AND MAINTENANCE MANUAL FOR MODEL 4040 P/N M78485 05/18/2015 DANGER Toxic and/or flammable gases or liquids may be present in this monitoring system. Personal protective equipment

More information

Hydrazine Analyzer Series 2171 Specifications

Hydrazine Analyzer Series 2171 Specifications Hydrazine Analyzer Series 2171 Specifications 70-82-03-64 November 2009 Introduction The 2171 is the most advanced hydrazine instrument specifically developed for use in continuous measurement and determination

More information

VM-3000 Mercury Vapor Monitor

VM-3000 Mercury Vapor Monitor MERCURY INSTRUMENTS Analytical Technologies VM-3000 Mercury Vapor Monitor Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Proven reliable detection method: UV absorption

More information

Using the DewTrak II Dew Point/ Humidity Transmitter

Using the DewTrak II Dew Point/ Humidity Transmitter APPLICATION NOTE 2016_FEB2 DT Rev 10 Using the DewTrak II Dew Point/ Humidity Transmitter The Model DewTrak ll Dew Point/Humidity Transmitter is a compact, cost effective, optical chilled mirror hygrometer.

More information

Nov 08 PRODUCT SPECIFICATION SHEET

Nov 08 PRODUCT SPECIFICATION SHEET Honeywell UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 Nov 08 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN

More information

Teledyne Analytical Instruments. Oxygen Monitor System

Teledyne Analytical Instruments. Oxygen Monitor System Oxygen Monitor System Teledyne Analytical Instruments 3220 Oxygen Monitor System P/N: M73831 ECO# 01-0267 10/05/01 Teledyne Analytical Instruments i Model 3220 Instruction Manual Model 3220 Multi-Channel

More information

Zareba Metro Gas Detector

Zareba Metro Gas Detector Zareba Metro Gas Detector The Metro addressable gas detector enables remote monitoring of flammable and toxic gas hazards Metro Gas Detector One-Stop Shop Flammable and toxic gas monitors available Methane,

More information

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL GASGUARD O 2 Oxygen Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6 Operation.. 7 Start-up...

More information

Unipoint controller. The Unipoint, a simple DIN rail mounted controller

Unipoint controller. The Unipoint, a simple DIN rail mounted controller Unipoint controller The Unipoint, a simple DIN rail mounted controller Unipoint DIN controller Typical Applications Small and medium integrated systems ustom control cabinets and panels Unmanned equipment

More information

02/11/2015

02/11/2015 CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint

More information

Airflow Sensors Line Guide

Airflow Sensors Line Guide Line Guide Go with the flow of engineering leadership. All airflow sensors operate on heat transfer flow and differential pressure. But Honeywell Sensing and Control (S&C) offers advanced chip design,

More information

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION GMS-10 RVS Series Oxygen Sensors Accurate oxygen measurement DESCRIPTION The GMS-10 is a high-accuracy oxygen sensor suitable for many applications. Originally developed for boiler applications, the product

More information

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head 4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head NET DRAFT version 2.1-2008 Pag. 1 4-20mA Cyber - DRAFT version 2.1-2008 Pag.

More information

IAQ_100 C Package

IAQ_100 C Package 15x15 Indoor Air Quality Sensor 100 ppm C Package 110-802 DESCRIPTION SPEC Sensors IAQ_100 is a Screen Printed ElectroChemical sensor component specifically designed for the broad detection of gases associated

More information

Application Note Honeywell Zephyr Analog and Digital Airflow Sensors: HAF Series-High Accuracy, ±50 SCCM to ±750 SCCM

Application Note Honeywell Zephyr Analog and Digital Airflow Sensors: HAF Series-High Accuracy, ±50 SCCM to ±750 SCCM Solutions Honeywell s Zephyr Analog and Digital Airflow Sensors: HAF Series-High Accuracy sensors provide an analog or digital interface for reading airflow over the specified full-scale flow span and

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors

More information

Industrial Grade Gas Detection

Industrial Grade Gas Detection Industrial Grade Gas Detection DETECTING THE... Difference Catalog #CB 0112 detcon inc. an company www.detcon.com Houston Odessa Shanghai Dammam Del Carmen Europe Company Profile ISO 9001: 2008 Certified

More information

02/11/2015

02/11/2015 MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS

More information

OPERATING INSTRUCTIONS. Model 3010PAC. Percent Oxygen Analyzer

OPERATING INSTRUCTIONS. Model 3010PAC. Percent Oxygen Analyzer Oxygen Analyzer OPERATING INSTRUCTIONS Model 3010PAC Percent Oxygen Analyzer Flush Mount Control Unit, PN D-66192B CENELEC Type Remote Probe, PN B-39923C Intrinsic Safe Barriers Assy., PN C-66426 DANGER

More information

Recent Improvements in Process GC Instrumentation

Recent Improvements in Process GC Instrumentation ISA Houston, TX Oct., 15 2003 Recent Improvements in Process GC Instrumentation Dr. Jack Driscoll PID Analyzers, LLC copyright 2000-2006 PID Presentation Objectives A new Process GC has been developed

More information

ENVAIR lab CO2 Tri-Gas Incubator

ENVAIR lab CO2 Tri-Gas Incubator ENVAIR lab CO2 Tri-Gas Incubator Laboratory Incubator ENVAIR lab CO2 Tri-Gas Incubator Introduction ENVAIR lab Tri-Gas Incubator, providing precise temperature, C02, 02 control as well as high humidity,

More information

High Pressure Conductivity Monitor

High Pressure Conductivity Monitor Product Data Sheet PDS 71-EDS880/1/rev.A August 2006 Model EDS880/1 High Pressure Conductivity Monitor COMPLETE SYSTEM FOR THE DETERMINATION OF CONDUCTIVITY IN HIGH PRESSURE SYSTEMS SENSOR INSTALLS DIRECTLY

More information

Industrial Grade Gas Detection

Industrial Grade Gas Detection Industrial Grade Gas Detection DETECTING THE... Difference Catalog #CB 0912 detcon inc. an company www.detcon.com Houston Odessa Shanghai Dammam Del Carmen UK Company Profile ISO 9001: 2008 Certified 105-A

More information

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller Unipoint ontroller The Unipoint, a simple DIN rail mounted controller Unipoint DIN ontroller Typical Applications Small and medium integrated systems ustom control cabinets and panels Unmanned equipment

More information

Air Check O 2 Deficiency Monitor 0-25%

Air Check O 2 Deficiency Monitor 0-25% Air Check O 2 Deficiency Monitor 0-25% Instruction Manual RS-485 Revision 4.05 Part number 99066 PureAire Monitoring Systems, Inc. 557 Capital Drive Lake Zurich, Illinois 60047 Phone: 847-726-6000 Fax:

More information

HPLC Column Ovens and Temperature Controllers

HPLC Column Ovens and Temperature Controllers HPLC Column Ovens and Controllers Improve your separation performance today! Accurate temperature control of your HPLC columns will improve the reproducibility of your results. Operating at increased temperatures

More information

SAM-MAX Refrigerant Monitors

SAM-MAX Refrigerant Monitors SAM-MAX Refrigerant Monitors Monitor Refrigerants Including CFCs, HFCs and Ammonia Monitor Carbon Monoxide Exceeds ASHRAE 5-99 and USEPA 608 Monitoring Requirements Provide for Single or Multipoint Sampling

More information

S304 and S305 Dust Emission Monitors. User Manual. Distributor

S304 and S305 Dust Emission Monitors. User Manual. Distributor S304 and S305 Dust Emission Monitors User Manual Distributor Version 6.4 30/5/2012 Table of Contents 1. INTRODUCTION... 3 1.1 Safety... 3 1.2 Product overview... 4 1.3 Principle of operation... 4 2. INSTALLATION...

More information