Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS
|
|
- Ashlynn Parsons
- 5 years ago
- Views:
Transcription
1 Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS Ex td A20, A20/21, A20/22, A21 IP66 T
2 Contents 1 Area of applicability 3 2 General information Zone 20 instruments Zone 20/21 instruments Zone 21 instruments 3 3 Technical data Electrical data 4 4 Application conditions Permissible ambient temperatures Max. surface temperature Permissible process pressure on the sensor Protection rating 6 5 Cable entries 6 6 Installation, mounting 6 7 Grounding 6 8 Material resistance 6 9 Locking mechanism of housing cover 7 Please note: These safety instructions are part of the documentation: l VEGADIF ma ma/hart Profibus PA Foundation Fieldbus l IECEx certificate IECEx BVS VEGADIF DF65.GX*****H/Z/P/F*****
3 1 Area of applicability These safety instructions apply to the differential pressure transmitters series VEGADIF DF65. GX*****H/Z/P/F***** according to IECEx certificate IECEx BVS (certificate number on the type label) and for all instruments with the number of the safety instruction (37675) on the type label. 2 General information The differential pressure transmitters series VEGADIF DF65.GX*****H/Z/P/F***** are used for monitoring or control also in areas with combustible, dust generating bulk solids. The VEGADIF DF65.GX*****H/Z/P/F***** consist of a differential pressure transmitter unit (sensor), a metal process connection element and a processing electronics in a metal housing. An indicating and adjustment module can be optionally mounted into VEGADIF DF65.GX*****H/Z/P/ F*****. The VEGADIF DF65.GX*****H/Z/P/F***** are suitable for use in hazardous atmospheres of all combustible dusts, for applications requiring instruments of category zone 20, zone 20/21 or zone 21. If the VEGADIF DF65.GX*****H/Z/P/F***** are installed and operated in hazardous areas, the general Ex installation regulations IEC as well as these safety instructions must be observed. The requirements of IEC e.g. with respect to dust and temperatures must be fulfilled. The operating instructions as well as the applicable, valid Ex mounting regulations and standards for electrical equipment must be observed. The installation of explosion-endangered systems must always be carried out by qualified personnel. 2.1 Zone 20 instruments The VEGADIF DF65.GX*****H/Z/P/F***** are installed in hazardous areas requiring instruments of zone Zone 20/21 instruments In applications as zone 20/21 instrument, VEGADIF DF65.GX*****H/Z/P/F***** are installed in the separating wall separating areas from each other in which zone 21 or zone 20 instruments are required. The electronics housing is in the hazardous area requiring a zone 21 instrument and the sensor is in the hazardous area requiring a zone 20 instrument. 2.3 Zone 21 instruments The VEGADIF DF65.GX*****H/Z/P/F***** are installed in hazardous areas requiring instruments of zone 21. VEGADIF DF65.GX*****H/Z/P/F***** 3
4 3 Technical data 3.1 Electrical data The VEGADIF DF65.GX*****H/Z/P/F***** with integrated electronics module DF60* have intrinsically safe circuits. These intrinsically safe circuits are connected to terminals located in the "Ex-i" connection compartment. VEGADIF DF65.GX*****H/Z***** Power supply and signal circuit: (terminals 1[+], 2[-] in electronics compartment; with double chamber housing version in connection compartment) In ignition protection type intrinsic safety Ex ia IIC For connection to a certified, intrinsically safe circuit. Maximum values: U i = 30 V I i = 131 ma P i = 983 mw The effective internal capacitance is C i = 5 nf. The effective internal inductance L i is negligibly small. VEGADF DF65.GX*****P/F***** Power supply and signal circuit: (terminals 1[+], 2[-] in electronics compartment; with double chamber housing version in connection compartment) In ignition protection type intrinsic safety Ex ia IIC/IIB for instruments of zone 0 resp. zone 1 and Ex ia IIC/ IIB resp. Ex ib IIC/IIB for instruments of zone 1. For connection to a certified, intrinsically safe circuit. Maximum values: U i = 17.5 V I i = 500 ma P i = 5.5 W The instrument is suitable for connection to a Fieldbus system according to the FISCO model (IEC ), e.g. Profibus PA or Foundation Fieldbus. or U i = 24 V I i = 250 ma P i = 1.2 W The effective internal capacitance is C i = 5 nf. The effective internal inductance L i is negligibly small. 4 VEGADIF DF65.GX*****H/Z/P/F*****
5 VEGADIF DF65.GX*****H/Z/P/F***** Indicating and adjustment circuit: (terminals 5, 6, 7, 8 in electronics compartment) Communication circuit: (I²C-BUS socket in electronics compartment; with double chamber housing version also in connection compartment) Circuit of the indicating and adjustment module: (spring contacts in the electronics compartment; with double chamber housing version also in the connection compartment) In ignition protection type intrinsic safety Ex ia IIC Only for connection to the intrinsically safe supply and signal cuitcuit of the corresponding external indicating and adjustment unit VEGADIS 61 (IECEx BVS ). The regulations for the interconnection of intrinsically safe circuits between VEGADIF DF65.GX*****H/Z/P/ F***** and the external indication unit are complied with if the total inductance and total capacity of the connection cable between VEGADIF DF65. GX*****H/Z/P/F***** and the external indication unit (L cable = 100 µh and C cable = 2.8 µf) are not exceeded. The indication and adjustment module integrated in VEGADIF DF65.GX*****H/Z/P/F***** and the connected interface converter are taken into account. In ignition protection type intrinsic safety Ex ia IIC Only for connection to the intrinsically safe signal circuit of an interface converter VEGACONNECT. In ignition protection type intrinsic safety Ex ia IIC Only for connection to the indicating and adjustment module PLICSCOM. With the double chamber housing version, the indicating and adjustment module may be mounted either in the electronics compartment or in the connection compartment. The intrinsically safe supply and signal circuit of VEGADIF DF65.GX*****H/Z/P/F***** is galvanically separated from parts that can be grounded. The metallic parts of the VEGADIF DF65.GX*****H/Z/P/F***** are electrically connected with the earth terminals. 4 Application conditions 4.1 Permissible ambient temperatures On the sensor, zone 20 or 21 VEGADIF DF65.GX*****H/Z/P/F***** C On the electronics housing, zone 20 or zone 21 VEGADIF DF65.GX*****H/Z/P/F***** C VEGADIF DF65.GX*****H/Z/P/F***** 5
6 4.2 Max. surface temperature On the sensor, zone 20 or 21 VEGADIF DF65.GX*****H/Z/P/F***** Process temperature +3 K On the electronics housing, zone 20 or zone 21 VEGADIF DF65.GX*****H/Z/P/F***** Process temperature +9 K 4.3 Permissible process pressure on the sensor The process pressure during operation in an explosive atmosphere requiring a zone 20 instrument must be between bar. The permissible combinations of application pressure and application temperature are stated in the operating instructions. 4.4 Protection rating Housing protection rating, housing in zone 20 or zone 21: IP 66 Sensor in zone 20 or zone 21: IP 67/IP 68 5 Cable entries The cable entry sent with the delivery is suitable for the housing temperature range specified in the VEGADIF DF65.GX*****H/Z/P/F***** certificate. If a different cable entry is used, the separately certified cable entry/gland (according to ATEX) determines the max. permissible ambient temperature on the housing (max. values: -40 C, +98 C). 6 Installation, mounting The VEGADIF DF65.GX*****H/Z/P/F***** as zone 20, 20/21 instruments must be installed in a way that excludes contact between the sensor and the vessel wall, taking vessel installations and the bulk solid in the vessel into account. 7 Grounding The VEGADIF DF65.GX*****H/Z/P/F***** must be grounded, for example via the ground connection terminal. 8 Material resistance The VEGADIF DF65.GX*****H/Z/P/F***** must only be used in media against which the materials of the wetted parts are sufficiently resistant. 6 VEGADIF DF65.GX*****H/Z/P/F*****
7 9 Locking mechanism of housing cover With single-chamber housing versions, the lid must be screwed in to the stop and secured with the locking device before setup and use of VEGADIF DF65.GX*****H/Z/P/F***** in hazardous atmospheres. With double-chamber housing versions, the lid of the connection compartment and the lid of the electronics compartment must be screwed in to the stop and secured with the corresponding locking device before setup and use of VEGADIF DF65.GX*****H/Z/P/F***** in hazardous atmospheres. Single chamber housing 1 1 Locking screw of the cover Clamp 2 Locking screw of the cover VEGADIF DF65.GX*****H/Z/P/F***** 7
8 Double chamber housing with "Ex-d" connection compartment "Ex-i" connection compartment with electronics module 2 Locking screw of the cover 3 "Ex d" connection compartment with integrated barrier 8 VEGADIF DF65.GX*****H/Z/P/F*****
9 VEGADIF DF65.GX*****H/Z/P/F***** 9
10 10 VEGADIF DF65.GX*****H/Z/P/F*****
11 VEGADIF DF65.GX*****H/Z/P/F***** 11
12 VEGA Grieshaber KG Am Hohenstein Schiltach Germany Phone Fax ISO 9001 VEGA Grieshaber KG, Schiltach/Germany 2010 Subject to change without prior notice
Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******
Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O****** CSA 14.2662675 Ex ia IIC T6 Ga, Gb 0044 Document ID: 48924 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical
More informationSafety instructions VEGAPULS 64
Safety instructions Intrinsic safety "i" 4 20 ma/hart - two-wire Document ID: 53001 Contents 1 Area of applicability... 3 2 Important specification in the type code... 3 3 Different ignition protection
More informationSafety instructions VEGABAR 81, 82, 83, 86, 87
C US Safety instructions VEGABAR 81, 82, 83, 86, 87 Dust ignition protection CSA 70015745 Document ID: 52267 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 4 4 Installation
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...
More informationOPTIBAR DP 7060 Supplementary Instructions
OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,
More informationSafety instructions VEGAMIP MPR61(*).G*/DK****R/T*** VEGAMIP MPT61(*).G*/DK****T*** VEGAMIP MPR62(*).G******R/T*** IECEx BVS Ex t IIIC T..
Safety instructions VEGAMIP MPR61(*).G*/DK****R/T*** VEGAMIP MPT61(*).G*/DK****T*** VEGAMIP MPR62(*).G******R/T*** IECEx BVS 09.0054 Ex t IIIC T.. Da, Da/Db, Da/Dc, Db IP 66 0044 41673 Contents 1 Area
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-nA Edition 08/207 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-d Edition 09/208 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4
More informationOPTIBAR P 1010/2010 C Supplementary instructions
OPTIBAR P 1010/2010 C Supplementary instructions Pressure transmitter Equipment category II 1G / Ga, II 1D / Da in protection type intrinsic safety Exi KROHNE CONTENTS OPTIBAR P 1010/2010 C 1 Safety instructions
More informationVERSAFLOW VORTEX Supplementary instructions
VERSAFLOW VORTEX Supplementary instructions Vortex flowmeter Equipment category II 2G CONTENTS VERSAFLOW VORTEX 1 Safety instructions 3 1.1 General notes... 3 1.2 EC conformity... 3 1.3 Approval according
More informationSafety instructions VEGAPULS 62
Safety instructions Intrinsic safety PTB 03 ATEX 2060 X 4 20 ma/hart - two-wire HW 2.0.0 - SW 4.0.0 0044 Document ID: 37311 Contents 1 Area of applicability... 4 2 General information... 4 3 Technical
More informationSafety instructions Display and adjustment module
Safety instructions Display and adjustment module PLICSCOM Intrinsic safety TUN 15 ATEX 161127 U 0044 Document ID: 52134 Contents 1 Area of applicability... 4 2 General information... 4 3 Important specification
More informationAnnubar Flowmeter Series
Reference Manual Appendix B Approvals Annubar Flowmeter Series Hazardous Locations Installations.................. page B-1 Rosemount 3051SFA Product Certifications.......... page B-1 Rosemount 3095MFA
More informationUser s Manual YTA610 and YTA710 NEPSI Certification
User s Manual YTA60 and YTA70 NEPSI Certification [Option code: /NS, /NS5 and /NF] st Edition . INTRODUCTION Thank you for purchasing the YTA60 and YTA70 Temperature transmitters. This manual contains
More informationInductive slot sensor
0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:3 Status: Current Date of Issue: 2010-10-04
More informationHygienic Instruction. EHEDG, Installation and Cleaning Instructions. VEGAVIB VB61, VB63 Hygienic process fittings. Document ID: 35483
Hygienic Instruction EHEDG, Installation and Cleaning Instructions VEGAVIB VB61, VB63 Hygienic process fittings Document ID: 35483 Contents Contents 1 About this document... 3 1.1 Function... 3 1.2 Scope...
More informationEU DECLARATION OF CONFORMITY
The Low Voltage Directive (LVD) 2014/35/EU and Electromagnetic Compatibility (EMC) Directive 2014/30/EU. Capacitive level sensor DLS 27N(T) Capacitive level sensor type DLS 27N(T) is designed to bistable
More informationManufacturer declaration. 3-A, Installation and Cleaning Instructions. VEGAPULS 63 Hygienic process fittings. Document ID: 46197
Manufacturer declaration 3-A, Installation and Cleaning Instructions VEGAPULS 63 Hygienic process fittings Document ID: 46197 Contents Contents 1 About this document... 3 1.1 Function... 3 1.2 Scope...
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Accessories BF 12 Mounting flange, 12 mm Technical Data specifications Switching element function NAMUR, NO Rated operating distance s n 4 mm Installation non-flush
More informationTechnical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm
More informationSITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.
General information 1 Marking of the degree of protection 2 SITRANS T SITRANS T Explosion protected temperature sensor Operating Instructions Range of uses 3 Installation 4 Assembly and disassembly 5 Commissioning
More informationTechnical Data. Dimensions
0102 Model Number Features 8 mm non-flush Stainless steel housing Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 8 mm
More informationOperating Instructions Edition 02/2007
Operating Instructions Edition 02/2007 Temperature Transmitter 7NG3214 with PROFIBUS PA 7NG3215 with FOUNDATION Fieldbus sitrans Introduction 1 General safety notes 2 SITRANS T Temperature transmitter
More informationSafety instructions VEGATOR 121, 122
Safety instructions Intrinsic safety TÜV 14 ATEX 134822 TÜV 14 ATEX 134826 X 0044 Document ID: 47469 Contents 1 Area of applicability... 4 2 General information... 4 3 Technical data... 4 4 Installation...
More informationOPTIWAVE X500 Supplementary Instructions
OPTIWAVE X500 Supplementary Instructions OPTIWAVE 3500 C OPTIWAVE 6500 C OPTIWAVE 7500 C Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE X500 1 General safety information 4 1.1
More informationFieldbus Non-Incendive Concept takes FISCO into Zone 2 and Division 2 hazardous areas. Phil Saward
Foundation Fieldbus End Users Council Australia Inc. 9 Corcoran St Duncraig, WA 6023 P.O.Box Z5546 Perth, WA 6831 AUSTRALIA ABN 60 120 236 370 Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and
More informationIECEx Certificate of Conformity
Page 1 of 10 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate
More informationContinuous and Point Level Measurement. Radiometric Sensors for Liquid and Solid Level Measurement
Continuous and Point Level Measurement Radiometric Sensors for Liquid and Solid Level Measurement Contents Leadership in Radiometric Technology 3 plics Easy is Better 4 FiberTrac 31 Continuous Level 6
More informationTechnologies, Solutions, and Applications. Radiation-based Level
Technologies, Solutions, and Applications Radiation-based Level Contents Leadership in Radiation-based Level 3 Principle of Operation 4 Models and Versions 6 Radiation-based Level in the plics System 8
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 8 mm
0102 Model Number Features 8 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
More informationProcessMaster, HygienicMaster FEX300, FEX500
SM/FEX300/FEX500/ATEX/IECEX-EN ProcessMaster, HygienicMaster FEX300, FEX500 ATEX / IECEx Zone 1, 2, 21, 22 Safety instructions for electrical apparatus in potentially explosive areas, in accordance with
More informationAdditional Information. Introduction. Temperature transmitter for all communications protocols. Redundancy thanks to two inputs. Measurement made easy
ABB MEASUREMENT & ANALYTICS COMMISSIONING INSTRUCTION TTF300 Field-mount temperature transmitter Temperature transmitter for all communications protocols. Redundancy thanks to two inputs. Measurement made
More informationSET Installation and Operating Instructions. Level switch for one sensor
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel.: +358 29 006 260 Fax: +358 29 006 1260 7.11.2013 Internet: www.labkotec.fi 1/14 SET-1000 Level switch for one sensor Copyright 2013 Labkotec Oy
More informationOilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor
Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush
More informationPEPPERL+FUCHS GmbH
Comfort series 1.5 mm embeddable M8x1 4 25 16 13 LED Switching element function NAMUR NC Rated operating distance s n 1,5 mm Installation embeddable Assured operating distance s a 0... 1,215 mm Reduction
More informationUser s Manual. EJA Series Differential Pressure and Pressure Transmitters Manual Change No Yokogawa Electric Corporation
User s Manual EJA Series Differential Pressure and Pressure Transmitters Manual Change No. 12-004 For the models EJA and EJA-A series with option code /KF21, /KU21, /KU22 or /KN26, please use this manual
More informationIntrinsically Safe Solutions
Intrinsically Safe Solutions INSTALLATION MANUAL 04/12/14 Rev D DOC-01-029 Documentation Feedback Your feedback helps us keep our documentation up to date and accurate. If you have any comments or suggestions
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No. : Status: Date of Issue: Applicant:
More informationOilSET Installation and Operating Instructions. Oil Separator Alarm Device
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 18.11.2010 Internet: www.labkotec.fi 1/10 OilSET-1000 Oil Separator Alarm Device Copyright 2010 Labkotec
More informationInstrumentation Products and Applications
1 1/0 Instrumentation Products and Applications 1 Instrumentation Safety barriers I.S. Isolators - DIN rail mounting - Eurocards - Modules Remote I/O Operating and monitoring systems Instrumentation systems
More informationRADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION
Special Safety Instruction en RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION Contents TankRadar Pro European ATEX Directive Information............................... 2 ATEX marking and Ex Certification
More informationD SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410
FIELDBUS INTRINSICALLY SAFE CONCEPT (FISCO) APPROVAL FISCO allows interconnection of intrinsically safe apparatus to associated apparatus not specially examined in such combination. The criteria for interconnection
More informationInstalling Foundation Fieldbus H1 in Hazardous Areas. Presented By: Jim Peterson Sr. Applications Engineer MTL/USA
Installing Foundation Fieldbus H1 in Hazardous Areas Presented By: Jim Peterson Sr. Applications Engineer MTL/USA (Divisions) (Zones) Zone 0 ia) Intrinsically Safe Class I Division 1 Explosion Proof Purged
More informationSET-2000 Oil/Sludge 12 VDC
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 12.2.2015 Internet: www.labkotec.fi 1/14 SET-2000 Oil/Sludge 12 VDC Alarm Device for Oil Separators with
More informationTechnical Data. Dimensions
0102 Model Number Features 15 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 15 mm Installation non-flush Assured operating distance s a 0...
More informationYTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,
User s Manual YTA Series Temperature Transmitters [Style: S3] Manual Change No. 10-008 Please use the attached sheets in the following manuals when the product is with /KU2 option and EN60000 Series based
More informationINSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon
INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing
More informationINSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C
PSD1001C INSTRUCTION MANUAL SIL 3 SIL 2 IIB Group Power Supply for Hazardous Area Equipment DINRail Model PSD1001C PSD1001C SIL 3 SIL 2 IIB Group Power Supply for hazardous Area Equipment ISM006510 General
More informationOilSET-1000 (12 VDC)
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 Internet: www.labkotec.fi 20.03.2009 1/11 OilSET-1000 (12 VDC) Oil Separator Alarm Device Copyright 2009
More informationIndoor/outdoor resistance thermometer Model TR60
Temperature Indoor/outdoor resistance thermometer Model TR60 WIKA data sheet TE 60.60 for further approvals see page 2 Applications Ambient temperature measurement Air-conditioned rooms, cold-storage rooms,
More informationSafety instructions VEGAVIB 61, 62, 63
Safety instructions Intrinsic safety PTB 05 ATEX 2077 X NAMUR 0044 Document ID: 53706 Contents 1 Area of applicability... 4 2 General information... 4 3 Technical data... 6 4 Application conditions...
More informationSupplementary instructions Bypass 72 Bypass tube with VEGAFLEX level sensor
Supplementary instructions Bypass 72 Bypass tube with VEGAFLEX level sensor Document ID: 33545 Guided Microwave 1 Product description 1 Product description Bypass 72 is a complete level measuring system
More informationIECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Certificate history: Status:
More informationRadiation-based measurement Detectors
Radiation-based measurement Detectors Overview 190 Detectors 192 Accessory 200 Radiation-based measurement - Detectors PROTRAC Radiation-based detector for level, density and mass flow measurement Measuring
More informationRadar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS
Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS SITRANS LR 400 Quick Start Manual This manual outlines the essential features and functions of the SITRANS LR 400
More informationAssembly. Host Sub-D Alarm
HighDensity Power Hub, Generic Interface Features Assembly 4 segments, loadsharing redundancy Output: 22... 24 V/360 ma, Ex ib IIC for intrinsically safe, highpower segments Redundant connection to PROFIBUS
More informationProduct Information to the manual
Product Information to the manual Distributed I/O device ET 200iS, Version 10/2001 Introduction This product information contains fixes and additional information relevant to the user manual Distributed
More informationA Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document
A190325 Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document CONTENTS INTRODUCTION 1. DUAL CERTIFIED COMPONENTS 1.1 Simple Apparatus Switches For
More informationSET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions
SET-000 Oil/Sludge Alarm Device for Oil Separators Copyright 007 Labkotec Oy We reserve the right for changes without notice TABLE OF CONTENTS GENERAL... INSTALLATION... 4. SET-000 Oil/Sludge Control Unit...
More informationTechnical Data. Dimensions
0102 Model Number Features 5 mm flush Usable up to SIL2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching element
More informationPROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC
PROCESS AUTOMATION Instruction manual Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC With regard to the supply of products, the current issue of the following document is applicable: The General
More informationInstallationsmanual GWSL1100/2100, GWML3100
GRAIN-WATCH SYSTEM Installationsmanual Grain Watch Sensor Cables GWSL1100/2100, GWML3100 Table of contents 1 1 1 3. Safety certification and features 3.1. Certification label information 3.2. Safety approvals
More informationPROFIBUS-PA Display RID 261 PROFIBUS-PA
Technical Information TI 071R/09/en Mat.-Nr.: 510 01194 PROFIBUS-PA Display RID 261 PROFIBUS-PA Display of process values and set point alarms on PROFIBUS-PA systems R Applications Direct connection to
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 50 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 50 mm Installation non-flush Output polarity NAMUR
More informationSET-2000 Hi Level/Oil
Labkotec Oy Labkotie 1 FI-36240 KANGASALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 13.03.2008 Internet: www.labkotec.fi Alarm Device for Oil Separators Copyright 2008 Labkotec Oy We reserve
More informationManual Power relay SR853
Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
0102 Model Number Features Direct mounting on standard actuators EC-Type Examination Certificate TÜV99 ATEX 1479X Accessories BT32 BT32XS BT32XAS BT33 BT34 V1-G-N4-5M-PUR Female cordset, M12, 4-pin, NAMUR,
More informationTank Gauging System Special Safety Instruction
Tank Gauging System www.rosemount-tg.com Rosemount TankRadar REX Table of Contents Contents SPECIAL SAFETY INSTRUCTION........................ 1-1 1. GENERAL REQUIREMENTS....................... 1-2 1.1
More informationPROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO
PROZESSAUTOMATION Manual SEGMENT PROTECTOR R-SP-!12 FieldConnex TM Segment Protectors with overloaod protection and short-circuit current limitation for the connection of 12 field devices Zone 1 Zone 2
More informationSEK-3 Marine Grounding System
Humboldtstr. 29 21509 Glinde / Germany info@timm-elektronik.de SEK-3 Marine Grounding System Version 1.1 / English Updated: September 2017 Table of Contents 1 SEK-3 Marine Grounding System and Accessories...
More informationSBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)
SBEx-4 BISTATE SEPARATOR,, 3 or 4 channels in rail housing (TS3,,mm width) - group I category (M), group II and III category () accompanying device, - intrinsically safe input circuits with ia protection
More informationSafety instructions VEGAPULS 69
Safety instructions VEGAPULS 69 Dust ignition protection by enclosure 4 20 ma/hart - two-wire 4 20 ma/hart - four-wire Profibus PA Foundation Fieldbus Modbus 0044 Document ID: 53030 Contents 1 Area of
More informationEUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU
EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU GENERAL The accidental ignition of an atmosphere containing a large quantity of gas, vapour, mists and/or dust may cause an explosion. Specific
More informationTemperature measurement with SITRANS T siemens.com/processinstrumentation
Top values in precision and reliability Temperature measurement with SITRANS T siemens.com/processinstrumentation Temperatures firmly under control Top process quality and efficiency are key factors for
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61784-5-3 Edition 2.0 2010-07 colour inside Industrial communication networks Profiles Part 5-3: Installation of fieldbuses Installation profiles for CPF 3 INTERNATIONAL ELECTROTECHNICAL
More informationThe R. STAHL Technology Group Worldwide Success with Competence and Customer Support
The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The entrepreneurial basis of the R. STAHL Technology Group follows a long tradition. The product range is aimed at specialised
More informationTemperature Measurement Transmitters for field mounting
Siemens AG 07 Overview Application The SITRANS TF can be used everywhere where temperatures need to be measured under particularly harsh conditions. For that reasons users from all industries have opted
More informationPage 1 Copyright by the Fieldbus Foundation All rights reserved.
Page 1 Copyright by the Fieldbus Foundation 1996-2004.. FOUNDATION Fieldbus Application Guide 31,25 kbit/s Intrinsically Safe Systems AG-163 Revision 2.0 This application guide has been prepared to aid
More informationRosemount 3144P Rosemount 3144P Temperature Transmitter
Temperature Transmitter Sensor Drift Alert and Hot Backup features improve measurement reliability while the Transmitter-Sensor Matching feature improves temperature measurement accuracy Statistical Process
More informationGTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres
Z31.0.XX.6C-11 Temperature Probe for potentially explosive atmospheres (Measuring ranges from -200 to +900 C) Operating Manual GTF 103-Ex 0081 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße
More informationDSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor
Product ID Type # Product # Drawing # DSF 1210.00 SHV Ex-atex (2m) 374Z-05066 110428F1 DSF 1210.00 SHV Ex-atex (5m) 374Z-05176 110428F1 DSF 1210.00 SHV Ex-atex (10m) 374Z-05590 110428F1 DSF 1410.00 SHV
More informationManual Isolating Barrier D461R1 (Revision 01)
D461R1 Manual Isolating Barrier D461R1 (Revision 01) Product Manual Original Instructions valid for models D461R1.11 with 1x signal input into 1x isolated signal output D461R1.12 with 1x signal input into
More informationOOH740-A9-Ex Multi-sensor fire detector
OOH740-A9-Ex Multi-sensor fire detector ASAtechnology TM For potentially explosive areas Cerberus PRO Collective Signal processing with ASAtechnology Multiple protocol detector (collective/c-net-ex) Event-controlled
More informationOOH740-A9-Ex Multisensor fire detector
OOH740-A9-Ex Multisensor fire detector ASAtechnology TM For potentially explosive areas Cerberus PRO Collective Signal processing with ASAtechnology Multiple protocol detector (collective/c-net-ex) Event-controlled
More information4) Intrinsic Safety Certification
INSTRUCTION MANUAL Minialert Intrinsically Safe Round Combined Unit Section Volume Control Tone Generator S2 S3 Tone Selection Switches Fig 1 Simplified block diagram The combined unit is CE marked for
More informationDeclaration of conformity
File: ATEX Manoswitch DoC 2017-10-20 Rev: 2017-10-20 id: mk Declaration of conformity The products listed in Appendix B, meet the requirements for a simple apparatus given by the standards listed below.
More informationManual. WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-xxx Definition of Terms, Marking and Installation Regulations. Version 1.0.
WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-xxx Definition of Terms, Marking and Installation Regulations 2 General WAGO-I/O-SYSTEM 750 General 2010 by WAGO Kontakttechnik GmbH & Co. KG All rights
More informationSafety instructions VEGASWING 61, 63
Safety instructions Intrinsic safety NAMUR 0044 Document ID: 50660 Contents 1 Area of applicability... 4 2 General information... 4 3 Technical data... 5 4 Application conditions... 6 5 Protection against
More informationSensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0
Sensor module Operating instructions Sensor module, Document No. 11-51P2-7D0001 Version: 17 May 2011/Rev. 0 Operating Instructions Sensor-Module Type: 17-51P2-. Document no.: 11-51P2-7D0001 Version: 17.
More informationAir Sensor. SAC Ex FCS Ex. Manual ATEX. AQ M-Tech AB
Air Sensor SAC Ex FCS Ex Manual AQ M-Tech AB ATEX Air Sensor SAC Ex FCS Ex ATEX Certified AQ M-Tech AB Manual version 2.2 February 2017 2 Air Sensor Manual for SAC Ex and FCS Ex Table of contents 1. Manufacturer
More informationPROTECT SRB 200EXi-1A
2 Installation up to zone 1/21 J S L1 0V X1 X3 S11 S12 S21 S22 Installation up to zone 2 A1 F1 F2 U B U EXi U i 0V S12 S22 X1 X3 K1 Logic K2 K1 K2 13 23 U EXi SRB 200EXi U B -1A U i K1 K2 PA PA A1 A2 13
More informationPROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY
PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY POINT LEVEL DETECTION In applications like overfill protection, min/max control, or overflow and dry-run protection, the limit value switches
More informationFixed-Point Interface Profiling. Multi-Point Density Array (MDA) Solution for Separation Applications
Fixed-Point Interface Profiling Multi-Point Density Array (MDA) Solution for Separation Applications Contents Leadership in Interface Profiling 3 System and Components Overview 4 Components 6 Principle
More informationUser s Manual. EJA Series Differential Pressure and Pressure Transmitters Installation Manual. 1. Introduction. 2. Handling Cautions. 3.
User s Manual EJA Series Differential Pressure and Pressure Transmitters Installation Manual 1. Introduction 1.1 For Safe Use of Product...2 1.2 Warranty...3 1.3 ATEX Documentation...4 2. Handling Cautions
More informationBA488CF Intrinsically safe Panel mounting Fieldbus Display
BA488CF Intrinsically safe Panel mounting Fieldbus Display Issue: 8 Issue: 8 8 th May 2006 2 CONTENTS 1. Description 1.1 Documentation 1.2 Version 2.0 firmware 2. Operation 2.1 Controls 3. Intrinsic Safety
More informationModel 144H. Product Data Sheet , Rev DB February Content
Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy
More informationQuick Start Guide For the
A Leader in Level Measurement Quick Start Guide For the Universal IV Lite and Universal IV Pro Model Transmitters 2-Wire RF Admittance / Capacitance Level Measurement System with HART Protocol For Assistance
More information