Seung-Jin Ind.Co.,Ltd.
|
|
- Mark Bryant
- 5 years ago
- Views:
Transcription
1 Seung-Jin Ind.Co.,Ltd
2 Contents Chapter 1 Introduction 1. About Seung-Jin Ind. Co. Ltd 2. Brief Company History 3. Organization Chart 4. Products Chapter 2 Flexible Sprinkler Hose With Fittings 1. Nut Type 2. Welding Type 3. For Residence Type 4. For Clean Room Type Chapter 3 Pump Connector 1. TPC 2. Loop type Flexible Joint 3.Metallic Flexible Joint 4. Metallic Flexible Hose 5. Flexible Rubber Connector Chapter 4 Expansion Joint 1. General Type 2. Control Ring Type 3. Hinge Type 4. Universal Type 5. Square Type 6. Non-Metal Type Chapter 5 Bellows 1. Bellows 2. GIS Type Chapter 6 Certificate 1. Certificates 2. Awards
3 Chapter 01. Introduction 1. About Seung-Jin Ind. Co. Ltd 2. Brief Company History 3. Organization Chart 4. Products
4 1-1 Introduction-1 About Seung-Jin Ind. Co., LTD We, Seung-Jin Industrial Company Ltd., located in Ansan-city, Gyunggi-Do Do, established in 1989 and incorporated in Jan, 1997 is the leading manufacturer of metallic flexible hose products. Our mainly products are fire sprinkler flexible hoses (SP-Joint), Flexible Joint, Expansion Joint, and Bellows. We have obtained the license from ISO and KS and certification of UL/ULc, FM and LPCB. We are exporting the products to Europe, Middle East, Asia, and Australia. We have been attending worldwide well-known fire-fighting exhibition for overseas marketing and doing our best for improving product quality. Application Area 1 Commercial Building 2 Hospital 3 Apartment 4 Ship (Fire sprinkler) 5 Plant and Factory Fields of Interest 1 Architect 2 Building Constructor 3 Plumbing Contractor
5 1-1 Introduction-2 Company Seung-Jin Ind.Co.,Ltd. President Ho Jin, Jung Established January 07, 1997 Address 5Ba-612, Sihwa Ind. Complex, , Sunggok-dong, Danwon-Gu, Ansan-si, Gyeonggi-do, Korea TEL/FAX TEL: / FAX: WEB / webmaster@seungjin.kr
6 1-2 Brief Company History Patent Registration (No ) Award a small-medium businesses of Gyeonggi-do for a technology Award a Korean national quality award Registration as a Venture Company Obtain the UL/ULc Certification Patent Registration (No ) Patent Registration (No , ) Award a Million USD Export Tower (From Korea Trade Association) Award Certificate of Export Industry (From Gyeonggi Province Governor) Registered as a Qualified Service company of KOMIPO(Korea Midland Power Company) 2009~ Appointed as Sub-supplier of Hyosung Heavy Industry Appointed as Sub-supplier of Hyundai Industry & development Appointed as Sub-supplier of POSCO 2005~ ~ ~ ~ Obtain the license of LPCB Obtain the license of FM Approvals Appointed as Sub-supplier of HDEC Obtain ISO-9001 Quality Certificate of Approval Obtain Permission to indicate of Korea Standard Establishment of Seung Jin Ind.Co.,Ltd Appointed as Sub-supplies of Dawoo Heavy Industry Establishment of Seung Jin Co.
7 1-3 Organization Chart CEO Technology Development Management Department Quality Control Department The Materials Department The accounting Department Sales Department Production-1 Production-2 Sales Management Department
8 1-4 Products Nut Type SP-Joint Welding Type For Residence Type For Cleanroom Type Products Metallic Flexible Joint T.P.C Loop Type Flexible Joint Flexible Hose Expansion Joint General e type Control Ring Type Hinge Type Universal Type Square Type Non-Metal Type Bellows Bellows GIS Bellows
9 Chapter 02. Flexible Sprinkler Hose With Fittings 1. Nut Type 2. Welding Type 3. For Residence Type 4. For Cleanroom Type 5. Accessories
10 2-1 FLEXIBLES SPRINKLER HOSE WITH FITTINGS Nut Type : Welding Type : Nut - Unbraid Nut Braid Etc Welding - Unbraid Welding Braid Etc For Residence Type : Unbraid Braid Etc For Cleanroom type : Cleanroom Commercial Type DUCT Type SGP Type
11 2-2 FLEXIBLES SPRINKLER HOSE WITH FITTINGS > Nut Type (Braid / UnBraid) Feature 1. Superior anti-corrosion 2. Easy of installation. Flexible-structured, fewer joints and lightweight. Easy positioning in installing pipes and easy to install even within a narrow space 3. High cost-effectiveness, requiring only a short period of works. Considerably reduced piping expenses by easily installation on site without complicated preparation works. 4. Various types of products. A wide range of selections based on their purpose and functions. 5. Available both in a dry and humid environment. 6. Obtained "UL/ULc and "FM" certification. Standard Length 700L, 1000L, 1200L, 1500L, 1800L, 2100L, 2500L, 2800L, 3100L
12 2-3 FLEXIBLES SPRINKLER HOSE WITH FITTINGS > Welding Type (Braid / UnBraid) Feature 1. Superior anti-corrosion 2. Easy of installation. Flexible-structured, fewer joints and lightweight. Easy positioning in installing pipes and easy to install even within a narrow space 3. High cost-effectiveness, requiring only a short period of works. Considerably reduced piping expenses by easily installation on site without complicated preparation works. 4. Various types of products. A wide range of selections based on their purpose and functions. 5. Available both in a dry and humid environment. 6. Obtained LPCB" certification. Standard Length 700L, 1000L, 1200L, 1500L, 1800L, 2100L, 2500L, 2800L, 3100L
13 2-4 FLEXIBLES SPRINKLER HOSE WITH FITTINGS > For Residence Type Feature 1. SP-Joint for apartment building is a unique product developed with a new construction method by our company. 2. Existing method is mostly the steel pipe joint method, which requires several processes and may cause excessive installation time and labor cost. 3. Our SP-Joint product with various kinds of mounting brackets is easy and simple to install in different type of ceiling structures. Standard Length 700L, 1000L, 1200L, 1500L, 1800L, 2100L, 2500L, 2800L, 3100L
14 2-5 FLEXIBLES SPRINKLER HOSE WITH FITTINGS > For Cleanroom Type Feature 1. Obtained "FM" approval for: - Clean Room - Commercial Ceiling -Duct -SGP 2. Designed for better safety for earthquake-proof facilities 3. Length : 800mm~2600mm 4. The SP Joint for cleanroom also can be installed at the a hospital, a hotel and a laboratory.
15 2-6 FLEXIBLES SPRINKLER HOSE WITH FITTINGS > For Accessories Type NO Contents Bend Nipple Elbow + Bracket for Resident Bracket Large Type Bracket Small Type Reducer O-ring (Black) / Slider-ring Square Bar
16 2-7 FLEXIBLES SPRINKLER HOSE WITH FITTINGS > Installation 1. Refer to the relative regulations, codes or standards for guidance and determination of the desirable location for the unit in use commercial ceiling, clean rooms and duct systems, etc. 2. Install the 1 flexible hose nipple (inlet) to the 1 sprinkler branch pipe by normal sealing and tightening procedures. Slip nut, which connects nipple with flexible hose, should be tightened with wrench as excessive force can damage the O-ring inside. (Torque: 120~125kgf cm, 125kgf 104inch-Lbs) Make sure that during and after installation of the flexible hose, any sharp-edged material or tools do not damage the surface of the flexible hose. 3. Assemble the supplied bracket and square bar as shown in the picture, and attach the square bar to the T-bar (ceiling support) with supplied bracket and bolts considering the horizontal location of the sprinkler head. At this stage of installation, bolts need to be fastened loosely. (Torque: 27~28kgf cm, 25inch-Lbs) 4. Bend the flexible hose so that the reducer (outlet) can be reached to the intended sprinkler head position. The flexible hose should be bent axially with smooth bending shape, and with minimum installation bending radius of 6. Flexible hose should not be twisted in a circumferential direction. For a longer flexible hose, intermediate hose support is recommended to secure the movement of the hoses 5. Verify that the reducer (outlet) is located in the correct intended position before securing the bracket bolt. Check and adjust the reducer position by moving vertically and horizontally along the square bar. Tighten all the bolts Securely and evenly. (Torque: 57~58kgf cm, 50inch-Lbs) 6. Install the sprinkler head to the reducer (outlet), t) if necessary adjust the height and location of the reducer by loosening and tightening the bolt.
17 2-8 FLEXIBLES SPRINKLER HOSE WITH FITTINGS > Technical Data-1 Available product length and type 700mm to 1800mm (28 to 70 ) Braided and Un-braided Available square bar length 700mm to 1500mm (28 to 59 ) Max. working pressure 14kgf/cm2 (200psi) Max. ambient temperature 107 (225 ) Minimum Installation Bending Radius 75mm (3 ) Bending Angles (Flow Direction) up to 180 Degree Largest K factor for 1/2 inch outlet 5.6[gpm/(psi) 1/2 ] Largest K factor for 3/4 inch outlet 14.0[gpm/(psi) 1/2 ] Intended use Wet and dry system This Flexible hose and fittings have limited flexibility. Intended use for direct connection to fire Sprinklers Flexible sprinkler hose fittings may be used in wet, preaction, deluge or dry pipe sprinkler systems between the branch line and sprinkler when installed in accordance with NFPA 13, Standard for the Installation of Sprinkler Systems, NFPA 13R, Standard for the Installation of Sprinkler Systems in Residential Occupancies up to Four Stories in Height, and NFPA 13D, Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Mobile Homes. A flexible sprinkler hose fitting consists of a flexible hose, inlet fitting for connection to the branch line, outlet fitting for connection to sprinkler, and a mounting bracket. These fittings are intended for use in hydraulically designed sprinkler systems. The hydraulic loss of these fittings needs to be included d in the hydraulic design calculations. l Losses vary depending on the installed configuration. The allowable number of bends with a minimum bend radius of 6in. (150mm) for each model and the associated pressure losses expressed in equivalent length in feet of 1 in. diameter Schedule 40 steel pipe (where C equals 120) are included in the following table Instructions for securing the anchoring components to the building components. If intended for use with drop ceilings, ceiling constructions o s are to be intermediate ed and heavy duty ceilings as described in the standard specification for the manufacture, performance, and testing of metal suspension systems for acoustical tile and Lay-in panel ceilings, ASTM C635 when installed in accordance with the standard practice for installation of metal ceiling suspension systems for acoustical tile and Lay-in panels, ASTM C636.
18 2-8 FLEXIBLES SPRINKLER HOSE WITH FITTINGS > Technical Data-2 Table 1 : Sprinkler Flexible Hose Fittings Model Model Length (ft) Outlet NPT/BSPT SJ-SPN /2 or 3/4 SJ-SPN /2 or 3/4 SJ-SPN /2 or 3/4 SJ-SPN /2 or 3/4 SJ-SPN /2 or 3/4 Table 2 : Friction Loss Data Model Nom Inlet by Outlet Size, in. Max No. of 90 Bends Min Bend Radius, in. Equivalent Length of 1 in. Schedule 40 Steel Pipe (C = 120), ft SJ-SPN x1/ SJ-SPN x1/ SJ-SPN x1/ SJ-SPN x1/ SJ-SPN x1/ SJ-SPN x3/ SJ-SPN x3/ SJ-SPN x3/ SJ-SPN SPN02 1x3/ SJ-SPN x3/
19 2-8 FLEXIBLES SPRINKLER HOSE WITH FITTINGS > Technical Data-3 Warranty This Fire-fighting sprinkler flexible hose fitting are designed to meet high quality and durability standards, and warrants to the original purchaser that its products are free from defects in materials and workmanship according to this installation instruction and use for a period of two years from the date of sale by us. This warranty does not apply to damage due directly or indirectly to misuse, abuse, or negligence, and dose not apply to products that have been installed, used or maintained in a manner contrary to our recommendations or instructions. To take advantage of this warranty, the product or parts must be returned to us. This warranty only extends to the original purchaser, and may not be assigned. Proof of purchase date and an explanation of the complaint with photo of job site must accompany the defect merchandise. If we verify the defect and determine that the product is covered by this warranty, we will either repair or replace the product at our election, or we may elect to refund the purchase price. (if loss occurs to the consumer due to our fault, that loss would also be compensated.) We will return repaired products at our expense, but if we determine that the defect resulted from causes not within the scope of our warranty, then we are not liable for warranty. This warranty is in lieu of all implied warranties, including but not limited to warranties of merchantability and warranties of fitness for a particular purpose. We shall not be responsible for any incidental or consequential damages, whether arising from any breach of this limited warranty or arising out of the sail of, use of, or defect in any of our products. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state
20 Chapter 03. Pump Connector 1. Loop Type Flexible Joint 2. T.P.C (Tie-rod Pump Connector) 3. Flexible Rubber Connector 4. Flexible Joint 5. Flexible Hose
21 3-1 Loop Type Flexible Joint & T.P.C Loop Type Flexible Joint Material : Bellows&Braid-STS304 / Flange-SS400 Pressure : 21.6Kg/ cm2 Temperature : 220 Application Fluid : Steam Water, Air, Gas T.P.C Material : Bellows-STS304 / Flange-SS400 Pressure : 10Kg/ cm2, 20Kg/ cm2 Temperature : 220 Application Fluid : Steam Water, Air, Gas
22 3-2 Metallic Flexible Joint & Flexible Rubber Connector Metallic Flexible Joint Material : Bellows-STS304 / Flange-SS400 Pressure : 10Kg/ cm2, 20Kg/ cm2 Temperature : 220 Application Fluid : Steam Water, Air, Gas Flexible Rubber Connector Material : EPDM / Flange : SS400 Pressure : 10Kg/ cm2, 20Kg/ cm2 Temperature : 80 Application Fluid : Steam Water, Air, Gas
23 3-3 Metallic Flexible Hose - 1 SFH100 Structure: A status of connecting a Nipple to a Tube by a Loose Nut Feature: Suitable for vibration or normal moving piping works Applied liquid: Cold & Hot water, oil, gas, steam, others Max. Temperature: 220 Max. Pressure: 10Kg/ cm2 Size: 6A~65A Length: 200L ~ 6000L SFH200 Structure: Connect the tube to Socket Feature: Selectable Nut material depends on liquid(ss400, STS304) Applied liquid: Cold & Hot water, oil, gas, steam, others Max. Temperature: 220 Max. Pressure: 10Kg/ cm2 Size: 6A~100A Length: 200L ~ 6000L
24 3-3 Metallic Flexible Hose - 2 SFH300 Structure: A status of connecting a Nipple to a Tube by a Loose Nut Feature: Suitable for vibration or normal moving piping works Applied liquid: Cold & Hot water, oil, gas, steam, others Max. Temperature: 220 Max. Pressure: 10Kg/ cm2 Size: 6A ~ 50A Length: 200L ~ 6000L SFH400 Structure: A status of connecting a Nipple to a Tube by a Loose Nut Feature: Suitable for vibration or normal moving piping works Applied liquid: Cold & Hot water, oil, gas, steam, others Max. Temperature: 220 Max. Pressure: 10Kg/ cm2 Size: 8A ~ 80A Length: 200L ~ 6000L
25 3-3 Metallic Flexible Hose - 3 SFH500 Structure: A status of connecting a Nipple to a Tube and connecting a sp coupler the nipple Feature: Easy piping, Fix & Release, Material selectable by applying liquids.(ss400, STS304) Applied liquid: Cold & Hot water, oil, gas, steam, others Max. Temperature: 220 Max. Pressure: 10Kg/ cm2 Size: 8A ~ 50A Length: 200L ~ 6000L SFH600 Structure: A type of connecting a nipple to a tube and connecting a Q coupling to the nipple Feature: Simple structure of a quick coupling, Easy piping, & Material selectable by applying liquids. Applied liquid: Cold & Hot water, oil, gas, steam, others Max. Temperature: 220 Max. Pressure: 10Kg/ cm2 Size: 15A ~200A Length: 200L ~ 6000L
26 3-3 Metallic Flexible Hose - 4 SFH700 Structure: A status of connecting a flange to a tube Feature: Easy piping and material of flange is selected by applying liquids. (SS400, STS304) Applied liquid: Cold & Hot water, oil, gas, steam, others Max. Temperature: 220 Max. Pressure: 10Kg/ cm2 Size: 10A ~ 500A Length: 200L ~ 6000L SFH800 Structure: A type of connecting a lap-joint to a tube so that a flange is rotating Feature: Suitable for vibration or normal piping works by using a lab=joint Applied liquid: Cold & Hot water, oil, gas, steam, others Max. Temperature: 220 Max. Pressure: 10Kg/ cm2 Size: 10A ~500A Length: 200L ~ 6000L
27 Chapter 04. Expansion Joint 1. General Type 2. Control Ring Type 3. Hinge Type 4. Universal Type 5. Square Type 6. Non-Metal Type
28 4-1 Expansion Joint > General Type General Type Material : Bellows STS304 Pipe SPP / STS304 Flange SS400 / STS304 Pressure : 10Kg/ cm2, 20Kg/ cm2 Temperature : 220 Application Fluid : Steam Water, Air, Gas,Oil
29 4-2 Expansion Joint > Control Type Feature It makes expansion functions even by inserting a ring between bellows and mainly be used for high pressure and also adjusts expansion limits with a bolt and adjust pipe. Specifications - Application: High pressure steam line, High temperature air line, High temperature and High pressure steam line, High pressure oil line, Gas line, Heat exchanger etc. - Pressure: 10Kg/ cm2, 30Kg/ cm2
30 4-3 Expansion Joint > Hinge Type Feature - It stands against internal thrust force by Hinge Arm, Hinge Pin of bellow side and absorbs Expansion of pipe with bellows force on each side. - Pressure: 10Kg/ cm2, 30Kg/ cm2
31 4-4 Expansion Joint > Universal Type Feature It is designed to absorb 3 directions displacement composed by 2 bellows, Tie Rod and center pipe. - Axis direction displacement absorption - Axis angular direction - Angular Movement Specifications - Application: Sinking of the ground for oil tank, Steam, oil piping, i power piping i etc. - Pressure: 2Kg/ cm2 ~ 20Kg/ cm2 - Temperature : 220
32 4-5 Expansion Joint > Square Type Feature It absorbs heat expansion of DUCT line so, it absorbs deformation or vibration from exhaust gas pipe and blower. Specifications - Application: Dust collection DUCT, Low pressure gas pipep - Pressure: 1Kg/ cm2 ~5Kg/ cm2
33 4-6 Expansion Joint > Non-Metal Type-1 Feature 1. Good protection of equipments by absorbing vibration and noise 2. Material selectable by displacement and elasticity 3. Easy material selection to have a high resistance against an high and a low temperature, a corrosion and a chemicals etc. 4. Easy assembly can save a cost in service works in sites
34 4-6 Expansion Joint > Non-Metal Type-2 Compare Metal Expansion Good for less vibration Good for a high pressure and an internal pressure Good for keeping a pressurizing High resistance against an abrasion by its high temperature deviation Good for a system which has less vibration VS Non-Metal Expansion Good for various displacement and a high elasticity Less strong against a pressure comparing to a metal type Good for absorbing vibration and noise Saving cost for design and labor Good for site works and anti-corresion and anti-chemical design Free shapes and size
35 Chapter 05. Bellows 1. Bellows 2. GIS Bellows
36 5 Bellows & GIS Bellows Bellows Material Thickness Size STS t~0.6t 25A~300A GIS Bellows Material Thickness Size STS t~0.6t 50A~250A
37 Chapter 06. Certificate 1. Certificate 2. Awards
38 6-1 Certificate > The list for Certificate Representative Good Certificate No. Issue Date 1 UL Flexible Sprinkler Hose Fittings EX FM APPROVALS Flexible Sprinkler Hose (For Clean Rooms Etc.) 外 LPCB Flexible Sprinkler SJ-SP Korean Standards association ISO 9001:2000 (Bellows Type Expansion Joint, Metallic Flexible Hose, SP Joint) QMS Korean Standards association KS B 1536 Bellows Expansion Joint 제 호 Korean Standards association KS B 1539 Metallic Flexible Hose 제 호 Small-Medium Business Administration INNO-BIZ Korea Technology Finance Co. Registration as a Venture Company
39 6-1-1 Certificate > UL/ULc
40 6-1-2 Certificate > FM Approvals
41 6-1-3 Certificate > LPCB
42 6-1-4 Certificate > Korean Standards Association for ISO9001:2000
43 6-1-5 Certificate > Korean Standards Association for KS B 1536
44 6-1-6 Certificate > Korean Standards Association for KS B 1539
45 6-2 Certificate > The list for Awards Award contents date From 1 Award Certificate of Export Industry For promote the export 03.24, 2008 Gyeonggi-do Administration 2 Award a Million USD Export Tower For a Million USD Export Tower 11.30, 2008 Korea Trade Association 3 Award a Korean national quality award For the Quality 11.25, 2009 Korean Standards association 4 Award a small-medium business of Gyeonggi-do for the technology 11.26, 2009 Small-Medium Business Administration
46 승진산업 Seung Jin Ind.Co.,Ltd Tel: Fax: Homepage:
Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A
Worldwide Contacts www.tyco-fire.com FASTFLEX Model YN25, YB25, and YB28 Flexible Hose Europe, Middle East, and Africa Only General Description The TYCO FASTFLEX Flexible Hose is a unique sprinkler drop
More informationSeries SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies
Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies SprinkFLEX Stainless Steel Sprinkler Fittings connect the branch line to the sprinkler using a flexible stainless
More informationBROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF
BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS Product Submittal A PART OF Limited Warranty SprinkFLEX warrants that its products will be free from defects in materials and workmanship under normal conditions
More informationModel vkfd28b braided flexible sprinkler drops (lpcb approved)
Page 1 of 6 1. DESCRIPTION Viking Flexible Sprinkler Drops are a complete assembly intended for installation into commercial suspended ceilings with medium to heavy support tee bars as described in ASTM
More informationTRUST THE ORIGINAL. SUBMITTAL PACKAGE
TRUST THE ORIGINAL. SUBMITTAL PACKAGE FlexHead Brochure We invented the concept of flexible fire protection The FlexHead Advantage FLEXHEAD QUALITY Best corrosion resistance Made from 100% 04 stainless
More informationPlease Read and Save These Instructions.
Page 1 of 8 RadonAway Ward Hill, MA. GP500 Fan Installation Instructions Please Read and Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL SERVICE
More informationSPRINKLER ALARM TECHNICAL DATA SPRINKLER ALARM MODEL - GA
SPRINKLER ALARM TECHNICAL DATA MODEL MOUNTING TYPE WATER WORKING PRESSURE CONNECTION GA Type-A & Type-B 17.5 Bar (250 PSI) Inlet : 3/4 BSPT (3/4 NPT) Drain : 1 BSPT (1 NPT) GONG DIAMETER 205mm (8 ) GONG
More informationInstallation Instructions / Warranty. Metris 31060XX XX XX1
Installation Instructions / Warranty Metris 31060XX1 31020XX1 31261XX1 Metris Single Control Lavatory Mixer 31060XX1 Tall Lavatory Mixer 31020XX1 Single Control Bidet Mixer 31261XX1 31060XX1 31020XX1 31261XX1
More information- FLEXIBLE SPRINKLER HOSE FITTINGS FOR USE WITH COMMERCIAL SUSPENDED CEILING AND CLEAN ROOM CEILING -
Nov-201 - FLEXIBLE SPRINKLER HOSE FITTINGS FOR USE WITH COMMERCIAL SUSPENDED CEILING AND CLEAN ROOM CEILING - - FLEXIBLE SPRINKLER HOSE FITTINGS FOR USE IN DUCTS - - WITH COMMERCIAL SUSPENDED CEILING AND
More informationI-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS I-VICFLEX.AB Victaulic VicFlex Style AB Sprinkler Fitting for Hat Furring Channel Ceiling Systems Read and understand all instructions before attempting to install any Victaulic
More informationInstallation Instructions / Warranty
Installation Instructions / Warranty Citterio M 34133XX1 Citterio M 34213XX1 Axor Citterio M widespread lavatory faucet 34133XX1 Axor Citterio M widespread bidet faucet 34213XX1 34213XX1 34133XX1 Technical
More informationModel/Sprinkler Identification Numbers
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description The Series TY-B, 5.6
More informationISO9001:2008 Cert Certified FIRE HYDRANTS. since SFFECO
ISO9001:2008 Cert. 403 Certified FIRE HYDRANTS SFFECO since www.sffeco.com DRY BARREL FIRE HYDRANT Meets all applicable parts of ANSI/AWWA C502 standard UL Listed (EX16453) and FM Approved (FM1510) 250
More informationWATER POWERED OSCILLATING MONITOR
WATER POWERED OSCILLATING MONITOR HD FIRE PROTECT TECHNICAL DATA MODEL VAJRA 331-S FLOW With 40U 500 or 750 or 1000 GPM. MINIMUM & MAXIMUM OPRATING PRESSURE FACTORY HYDROTESTED SWIVEL JOINT With HF40U
More informationELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR
ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR Model 91797 ASSEMBLY and Operating Instructions Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure
More informationSprinkler Permit Applications
REQUIREMENTS FOR NFPA 13 SYSTEM Building Inspections Sprinkler Permit Applications A complete application for a Sprinkler Permit will comply with the requirements of Chapter 8 of NFPA 13. Hydraulic calculations
More informationFLEXIBLE CORRUGATED TUBE
Back To The Natur e S O L A R S Y S T E M SPRINKLER SYSTEM B O I L E R FLEXIBLE CORRUGATED TUBE INSULATED SOLAR HOSES S Y S T E M w w w. k a s. c o m. t r SOLAR SYSTEM System Definition of Corrugated
More informationInstallation Instructions / Warranty
Installation Instructions / Warranty Metris 31063XX1 Metris 31263XX1 Talis 32310XX1 Focus 31730001 Metris Widespread Lavatory Faucet Metris Widespread Bidet Faucet Talis S Widespread Lavatory Faucet Focus
More informationJuna Ceiling Fan JU54. Installation Instructions Instrucciones de instalación Instructions d installation
Juna Ceiling Fan JU54 Installation Instructions Instrucciones de instalación Instructions d installation Read and Save These Safety Precautions. Turn off electricity at main switch before wiring or servicing
More informationInstruction Manual Hydraulic Crimping Tool
Instruction Manual Hydraulic Crimping Tool 902-480 Due to continuing improvements, actual product may differ slightly from the product described herein. Read this material before using this product. Failure
More informationModel A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.
Technical Services: Tel: (00) 31-9312 / Fax: (00) 91-5500 Customer Service/Sales: Tel: (1) 50-5000 / (00) 55-523 Fax: (1) 50-5010 / (00) -1295 Model A Pipe Line Strainer 3,,, & 10 Inch (DN0, DN100,, DN200
More informationSeries TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description
Technical Services: Tel: (800) 38-932 / Fax: (800) 79-5500 Series TY-B 2.8, 5.6, 8.0 K-factor Upright, Pendent, Recessed Pendent Sprinklers Stard Response, Stard Coverage General Description IMPORTANT
More informationSeries ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Customer Service/Sales: Tel: (215) 362-0700 / (800) 523-6512 Fax: (215) 362-5385 Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers
More informationThe Series LFII (TY3596) Residential
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series LFII Residential Concealed Pendent Sprinklers, Flat Plate 4.9 K-factor General Description The Tyco Rapid Response Series LFII (TY3596)
More informationSpecifications Component Size Weight Capacity Top Shelf 26-1/2 W x 18 L 305 lb Drawer A (x3) 22-1/2 W x 16 L x 2 D 75 lb each Drawer B (x2) 22-1/2 W x 16 L x 3-1/8 D 90 lb each Drawer C 22-1/2 W x 16 L
More informationRP, GP, XP Pro Series Installation Instructions
RP, GP, XP Pro Series Installation Instructions IN095 Rev B 0718 3 Saber Way, Ward Hill, MA 01835 radonaway.com 1 Fan Installation & Operating Instructions RP, GP, XP Series Fans Please Read and Save These
More informationINSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA
August 14, 2013 Sprinkler 126k 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Flush Horizontal Sidewall Sprinklers are small, flush, solder link and lever sprinklers made with tamper-resistant
More informationI-VICFLEX.AB3. Victaulic VicFlex Style AB3 Sprinkler Fittings for Surface Mount Applications WARNING WARNING INTRODUCTION
INSTALLATION INSTRUCTIONS I-VICFLEX. Victaulic VicFlex Style Sprinkler Fittings for Surface Mount Applications INTRODUCTION WARNING Read and understand all instructions before attempting to install any
More informationSeries ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Customer Service/Sales: Tel: (215) 362-0700 / (800) 523-6512 Fax: (215) 362-5385 Series ELO-231 Upright and Pendent Sprinklers Standard Response,
More informationINSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA
Page 1 of 8 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Standard Coverage/Extended Coverage Flush Pendent Sprinklers are small, flush, solder link and lever sprinklers made with tamper-resistant
More informationSpecifications. Dimensions 32" x 10" x 15" Cage Wire Thickness 3 / 16 " Page 2 For technical questions, please call
Specifications Dimensions 32" x 10" x 15" Cage Wire Thickness 3 / 16 " Page 2 For technical questions, please call 1-888-866-5797. Item 9646 IMPORTANT SAFETY INFORMATION 1. Use only where inaccessible
More informationTECHNICAL DATA. Wet 26a. February 22, 2009
February 22, 2009 Wet 26a 1. DESCRIPTION The Viking Alarm Check Valve serves as a check valve by trapping pressurized water above the clapper and preventing reverse flow from sprinkler piping. The valve
More informationINSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA
Sprinkler 126k Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Flush Horizontal
More informationHS Series Installation & Operating Instructions RadonAway
The World s Leading Radon Fan Manufaturer HS Series Installation & Operating Instructions RadonAway 3 Saber Way Ward Hill, MA 01835 www.radonaway.com P/N IN007-REV J 9/13 RadonAway Ward Hill, MA. HS Series
More informationAMERICA AMERICA 52 CEILING FAN INSTALLATION AND OPERATION MANUAL
AMERICA AMERICA 52 CEILING FAN INSTALLATION AND OPERATION MANUAL Ceiling Fan Weight Including Accessories: 21.00 Lbs. READ AND SAVE THESE INSTRUCTIONS TABLE OF CONTENTS Tools and Materials Required...
More informationWARNING. Flexible Hose AH2 With AB6 With AB6. AH2-CC With AB6 With AB6
INSTALLATION INSTRUCTIONS I-VICFLEX. Victaulic VicFlex Sprinkler Fittings: Style Bracket Assembly with Models V33,, or V40 Dry Sprinklers Read and understand all instructions before attempting to install
More informationSeries LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor General Description
Technical Services 800-381-9312 +1-401-781-8220 www.tyco-fire.com Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor General Description Pendent Sprinklers (TY2524) are decorative,
More informationSeries RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers
Technical Services 800-381-9312 +1-401-781-8220 www.tyco-fire.com Series RFII 5.6 K-factor Royal Flush II Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General Description The
More informationMOJAVE. Mojave ShowerSpa Model #1016 Owner's Manual
MOJAVE Mojave ShowerSpa Model #1016 Owner's Manual Mojave ShowerSpa Model #1016 Please Read The Following Instructions COMPLETELY Before Beginning! Our goal is to ensure your installation goes smoothly
More informationLaing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual
Installation & Operating Manual Please read this manual carefully before attempting to install, operate or maintain the product described. Failure to comply with the information provided in this manual
More informationHardwired Model Shown. Installation & Operation Manual for WarmlyYours Infinity Towel Warmers
Hardwired Model Shown Installation & Operation Manual for WarmlyYours Infinity Towel Warmers Thank you for choosing your finely crafted WarmlyYours Towel Warmer. Now you can add luxury and comfort to your
More informationInstallation Instructions / Warranty
Installation Instructions / Warranty Massaud 18112001 Massaud 18115001 Axor Massaud 3-Hole Lavatory Mixer Trim with Short Spout 18112001 Axor Massaud 3-Hole Lavatory Mixer Trim with Long Spout 18115001
More informationHS Series Installation & Operating Instructions RadonAway
The World s Leading Radon Fan Manufacturer HS Series Installation & Operating Instructions RadonAway 3 Saber Way Ward Hill, MA 01835 www.radonaway.com P/N IN007-REV K 10/15 RadonAway Ward Hill, MA. HS
More informationDOUBLE INTERLOCK, PREACTION SYSTEM WITH ELECTRIC/PNEUMATIC RELEASE
DOUBLE INTERLOCK, PREACTION SYSTEM WITH ELECTRIC/PNEUMATIC RELEASE HD FIRE PROTECT TECHNICAL DATA SIZE DELUGE VALVE CHECK VALVE SPRINKLER ALARM RELEASE PANEL 50, 80, 100, 150 & 200 NB Model H3, UL Listed
More informationPre-Pack INTEGRATED PRE-ACTION SYSTEM
Pre-Pack INTEGRATED PRE-ACTION SYSTEM HD FIRE PROTECT TECHNICAL DATA MODEL Pre-Pack SIZE DELUGE VALVE MODEL RISER CHECK VALVE MODEL WATER MOTOR GONG BELL MAXIMUM WORKING PRESSURE SYSTEM END CONNECTION
More informationInstallation Instructions / Warranty. Starck 10111XX XX XX1
Installation Instructions / Warranty Starck 10111XX1 10120XX1 10211XX1 90502203 1/2005 Starck single control lavatory faucet 10111XX1 Starck tall single control lavatory faucet 10120XX1 Starck single control
More informationThe Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.
The Extraordinaire Orbital Fan WARNING: Support Directly From Building Structure Net Weight 14.5 lbs. or 6.59 kg. Model No. OF110** OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Important Safety Instructions
More informationSeries EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description
Technical Services 800-381-9312 +1-401-781-8220 www.tyco-fire.com Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description
More information20 High velocity Air
20 High velocity Air Circulator 66878 Set up and Operating Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com
More informationTECHNICAL DATA OBSOLETE
October 10, 2008 Deluge Devices 281a 1. PRODUCT DESCRIPTION The Viking Model C-1 is a rate-of-rise releasing device for use on hydraulic and pneumatic release systems controlling operation of Viking deluge
More information55-Gallon Dispenser Package
INSTRUCTIONS-PARTS LIST Husky 515 55-Gallon Dispenser Package 08666 Rev.C INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 100 psi(6.9 bar) Maximum Air
More informationSprinkler Identification Numbers
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-50 Model Early Suppression Fast Response Pendent Sprinklers 16.8 K-factor General Description The Model Pendent Sprinklers (Ref. Figure 1) are Early
More informationPlease Read And Save These Instructions.
RadonAway Ward Hill, MA XP/GP/XR Series Fan Installation Instructions Please Read And Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL SERVICE
More informationTorrena 42 Ceiling Fan
Torrena 42 Ceiling Fan Owner s Manual Part # 269268, 269269 Model # 32096, 32097 Exclusively Distributed by: HD Supply Facilities Maintenance, Ltd. Atlanta, GA 30339 2017 Made in China If you are experiencing
More informationINSTALLATION MANUAL LITTLE BUTLER HOT WATER AND DRINKING WATER FILTRATION FAUCETS LB13250 LB13150 DW13050
INSTALLATION MANUAL LITTLE BUTLER HOT WATER AND DRINKING WATER FILTRATION FAUCETS LB13250 LB13150 DW13050 1 2 TECHNICAL DATA Recommended Water Pressure 35-75PSI Max. Water Pressure 145 PSI Recommended
More informationCamarillo 52 Ceiling Fan
Owner s Manual Camarillo 52 Ceiling Fan Part # 269263, 269259, 269287 Model # 32091, 32092, 32087 Exclusively Distributed by: HD Supply Facilities Maintenance, Ltd. Atlanta, GA 30339 2017 Made in China
More informationSF180 Installation Instructions
SF180 Installation Instructions 1 Fan Installation & Operating Instructions Please Read and Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL
More informationEXPANSION JOINT PRODUCTS
EXPANSION JOINT PRODUCTS CALL LOW PRESSURE AND HIGH PRESSURE METAL EXPANSION JOINTS Low pressure and high pressure Metal Expansion Joints are designed and manufactured in strict accordance with the Expansion
More informationCOBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM
SECTION 21 10 00 PART 1 - GENERAL 1.1 CODES A. Work shall conform to NFPA 13 Sprinkler Systems, 2002 Edition and NFPA 24 Outside Protection, 2002 Edition. NFPA 14 Standpipe Systems, 2000 Edition and International
More informationFFP S700 SERIES. Pull-Out Spray Faucet. Installation guide
FFP S700 SERIES Pull-Out Spray Faucet Installation guide G 1782 G 1748.XX G 29016 G 1156 G R0239.XX G 13396.XX G R0637 G R1664 G 1636 G 1463 TECHNICAL DATA Minimum working pressure 0,5 bar Maximum working
More informationModel WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-Factor General Description
Technical Services 800-381-9312 +1-401-781-8220 www.tyco-fire.com Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-Factor General Description The TYCO 5.6
More informationModel CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950
Technical Services 00--9 +-0--0 www.tyco-fire.com Model CV-FR Riser Check Valves to Inch (DN0 to DN00) General Description The TYCO Model CV-FR Riser Check Valve is a compact and rugged swingtype unit
More informationModel ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description
Worldwide Contacts www.tyco-fire.com Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description The TYCO Model ESFR-17 Dry Type Pendent Sprinklers (TY7229)
More informationSTEAM WALLPAPER STRIPPER MODEL HTW5
STEAM WALLPAPER STRIPPER MODEL HTW5 From Serial Number 75154 (110 Volt North America only) OWNERS MANUAL & OPERATING INSTRUCTIONS 2016/11 Hiretech Part # 007717 WARNING For safe operation of this machine,
More informationREAD AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual
READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER Water Tempering Device Installation, Operation, and Maintenance Manual Table of Contents Overview Features Summary...................................... 1
More informationEQ Joint High performance & Economical Price Stainless Steel welded Pipes & Tubes
www.eqjiont.com EQ Joint High performance & Economical Price Stainless Steel welded Pipes & Tubes EQ Jointech introduce EQ joint system is based on the introduction of technology from Germany and Japan,
More informationIN020 Rev F Page 1 of 8
IN020 Rev F Page 1 of 8 RadonAway Ward Hill, MA. Series Fan Installation Instructions Please Read and Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL
More informationSENJU SPRINKLER CO., LTD.
Page:1 of 8 SENJU SPRINKLER CO., LTD. Residential Lead Free Flat Concealed Sprinkler, Pendent, Model: RC-RES, K-Factor: 4.9, SIN: SS8464 GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed
More informationInstallation Instructions / Warranty
Installation Instructions / Warranty Interaktiv HighArc Kitchen Faucet with Pull-out HighArc Kitchen Faucet with Pull-out Spray Retroaktiv HighArc Kitchen Faucet with Pull-out Spray 3/8 supply hoses requires
More informationInstallation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5
Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5 Solar Mounting Solutions UNI-SA/21.5 March 2009 www.ironridge.com 2009 IronRidge, Inc. All Rights Reserved Version 2.0 2 Universal
More informationRL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.
Page 1 of 8 RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE
More informationTurin LED Ceiling Fan
Turin LED Ceiling Fan model no. no. 052-6972-6 Instruction Manual Toll-free: -866-827-4985 IMPORTANT: Please read and understand this manual before any assembly. Before beginning assembly of product, make
More informationModel ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description
Technical Services 800-381-9312 +1-401-781-8220 www.tyco-fire.com Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description The TYCO Model ESFR-17 Dry
More informationELECTRIC RADIANT OUTDOOR / INDOOR HEATER
ELECTRIC RADIANT OUTDOOR / INDOOR HEATER INSTALLATION, OPERATION & MAINTENANCE MANUAL IMPORTANT INSTRUCTIONS SAVE THESE INSTRUCTIONS Prior to installing and operating the heater, read these instructions
More informationUSER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES
USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES Bucket Fan 420 Bucket Fan 1055 Bucket Fan 1460 420 1055 1460 2 Bucket Fan CONTENT INTRODUCTION 3 USE 3 WHAT S INCLUDED IN THE BOX 3 DESIGNATION
More informationSeries TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description
Worldwide Contacts www.tyco-fire.com Series TY-B 2.8,.6, 8.0 K-factor Upright, Pendent, Recessed Pendent Sprinklers Stard Response, Stard Coverage General Description TYCO Series TY-B, 2.8,.6, 8.0 K-factor,
More informationDesign Criteria. Installation
Model G5 Sprinkler Guards for Use with Series DS-1 Sprinklers Standard, Deep, and No Escutcheons General Description The TYCO Model G5 Sprinkler Guards are designed for use with Series DS-1 Sprinklers
More informationModel ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage General Description
More informationFRESH AERO FlightLights LED Map Light For Grumman AA-5A & B Series Aircraft
FRESH AERO FlightLights LED Map Light For Grumman AA-5A & B Series Aircraft User Manual The Steelebrook Group Where Imagination Meets Innovation Thank you for purchasing the 4 late model AA-5 series aircraft.
More informationINSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators
INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators Models: PSX006XL PSD008XL PSD010XL CONTENTS: Part 1 - Planning The Installation Part 2 - Securing The Blower / Ventilator Part 3 - Electrical
More information2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST
Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 637 Louisville,
More informationSINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH WET PILOT ACTUATION
SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH WET PILOT ACTUATION HD FIRE PROTECT TECHNICAL DATA SIZE DELUGE VALVE CHECK VALVE SPRINKLER ALARM RELEASE PANEL 50, 80, 100, 150 & 200 NB Model H3, UL
More informationSingle Handle Lavatory Faucet
0GU3025 2007.5 TL170SD Single Handle Lavatory Faucet Installation and Owner s Manual RENESSE English Español Français Contents Important Safeguards------------1~2 Specifications -------------------------3
More informationAA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL
AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL Table of Contents Introduction 3 Incoming Inspection 3 General Safety & Warnings 3 Technical Specifications 4 Installation and Operation Instructions
More information10.85 VicFlex Sprinkler Fittings
Series AQB Braided Flexible Hose Assemblies VicFlex sprinkler fittings provide sprinkler installation on suspended ceiling grids, wood or metal stud/joist or hat furring channel hard-lid ceilings utilizing
More informationLIMITED LIFETIME WARRANTY
LIMITED LIFETIME WARRANTY To obtain Service, please contact or call Turn of the Century Service Department: 1-800-887-6326, 9 a.m.- 5 p.m. central time. Model No.: # 355-6782 The limited lifetime warranty
More informationSEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual
SEABREEZE SeaBreeze Rain Shower System Model #1086-CH Owner's Manual SeaBreeze Model #1086 Please Read The Following Instructions COMPLETELY Before Beginning! Our goal is to ensure your installation goes
More informationSINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH ELECTRIC RELEASE
SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH ELECTRIC RELEASE HD FIRE PROTECT TECHNICAL DATA SIZE DELUGE VALVE CHECK VALVE SPRINKLER ALARM RELEASE PANEL 50, 80, 100, 150 & 200 NB Model H3, UL Listed
More informationWINE AND BAR SERIES. Sink Installation Kit. For assistance, call ; for UK ; at
WINE AND BAR SERIES Sink Installation Kit For assistance, call 1.877.306.8930; for UK 0800.031.4069; e-mail at info@newageproducts.com Unpacking Begin by placing the package on a protected flat surface.
More informationTECHNICAL DATA. model c-2
Page 1 of 6 1. PRODUCT DESCRIPTION The Viking Model C-2 is a rate-of-rise releasing device for use on hydraulic and pneumatic release systems controlling operation of Viking deluge valves on deluge or
More informationModel ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description
Worldwide Contacts www.tyco-fire.com Model ESFR-17 16.8 K-factor Dry Type Pendent s Early Suppression, Fast Response General Description TYCO Model ESFR-17 Dry Type Pendent s are Early Suppression, Fast
More informationPanel Fan Series Operators Manual (Galvanized and Polymer)
Panel Fan Series Operators Manual (Galvanized and Polymer) 52" Belt Drive, Galvanized Panel Fan with Three Wing Blade IMPORTANT: READ AND SAVE THESE INSTRUCTIONS Read all instructions carefully before
More informationTHE HYTORC WASHER SYSTEM
THE WORLD S MOST TRUSTED INDUSTRIAL BOLTING SYSTEMS For improved Safety, Speed, and Accuracy on every industrial bolting job, the HYTORC Washer is the most convenient and economical solution available
More information36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)
36 & 48 E-Z Cone Fan Installation & Operator s Instruction Manual (Direct Drive) September 1997 MV1433C Chore-Time Warranty Chore-Time Equipment warrants each new product manufactured by it to be free
More informationLifetime Limited Warranty
Hampton Bay Lifetime Limited Warranty The retailer warrants the fan motor to be free from defects in workmanship and material present at time of shipment from the factory for a lifetime after the date
More informationLIMITED LIFETIME WARRANTY
LIMITED LIFETIME WARRANTY Model No.: F0023 / F0024 aireryder ORIGINAL CEILING FAN LIMITED LIFETIME WARRANTY The limited lifetime warranty covers this ceiling fan, for residential use by the original purchaser,
More informationINTERMEDIATE GUIDE BRACKET
BAIL ASSEMBLY AND CHAIN TOP RAIL SUPPORT SIDE MOUNT RAIL SUPPORT INTERMEDIATE GUIDE BRACKET LIFT-OUT RAIL SYSTEM 4" & 6" LIFT-OUT RAIL SYSTEMS INSTALLATION MANUAL WITH REPAIR PARTS LIST NOTE! To the installer:
More informationInstallation Instructions Model: EB Single-Lever Lavatory Faucet
by Dawn Kitchen & Bath Products, Inc. 877-Dawn-USA dp@dawnusa.net www.dawnusa.net Installation Instructions Model: EB1359150 Single-Lever Lavatory Faucet TABLE OF CONTENTS Preparation Parts Installation
More informationSENJU SPRINKLER CO., LTD.
Page:1 of 8 SENJU SPRINKLER CO., LTD. Residential, Pendent Sprinkler Model FR-RES K-Factor: 4.9 SIN: SS4451 GENERAL DESCRIPTION The Model FR-RES Residential Pendent and Recessed Pendent Sprinklers are
More informationInstallation Manual PS-225 & PS-275
Installation Manual PS-225 & PS-275 Table of Contents Pre-Uncrating Checklist... 1 Verifying System Requirements... 2 Verifying System Direction... 2 Verifying the Electrical Requirements... 2 Removal