HELPY QUICK-TL GSM INTL

Size: px
Start display at page:

Download "HELPY QUICK-TL GSM INTL"

Transcription

1 Alarm system for elevators HELPY QUICK-TL GSM INTL QUICK GUIDE 04/02/16

2 DESCRIPTION A B C D E F G H I L M N O Connector for external LEDs Connector for built-in loudspeaker Built-in loudspeaker Connector for internal power supply Connector for FlashKey Connector for external reset pushbutton Reset pushbutton Battery RJ45 connector for built-in GSM module Jumpers for telephone line (do not remove or move) Built-in microphone Connector for built-in microphone Terminal blocks DESCRIPTION Page 2

3 Terminal blocks: + Vacant - Negative pole AI Given alarm indicator light AR Received alarm indicator light Vdc output (max. 100mA) C Common terminal for inputs AL1 and IN1 - Negative pole AL1 Alarm input 1 AL2 Alarm input 2 IN1 Filter input ALT2 Output for connecting loudspeaker of passive handsfree terminal MIC2 Input for connecting microphone of passive handsfree or single microphone MIC3 Input for connecting microphone of passive handsfree or single microphone - Negative pole TEL Local telephone RL1 Relay door opener LTI Vacant Vacant - Negative pole V + Pit active handsfree P Q R Alarm pushbutton LEDs indicating device operation and GSM signal strength End alarm pushbutton (Reset pushbutton) Page 3 DESCRIPTION

4 Start operations Screw the antenna cable coming with the device into the dedicated external connector. Open the device by unscrewing the 4 upper screws; beware of the connection cable between the two built-in electronic boards. Insert the SIM card in the dedicated housing of the electronic board mounted on the metal cover. Make the connections on the terminal blocks. Connect the built-in battery (2Ah 12V). Plug the mains cable to the 230V socket. Close the metal cover paying attention to the connection cable between the two built-in electronic boards. Upon switching on, check that the HELPY led (device status led, Q in the picture) stays steady on for a few seconds and then starts flashing. If the HELPY led remains steady on, the built-in GSM module is not correctly registered to the GSM carrier (check the connection cable between the two built-in electronic boards, check that the SIM card is correctly inserted and that the PIN code has been removed). It takes about one minute before the GSM module is correctly registered. Check the GSM signal strength indicated by the GSM 200 led (Q in the picture). HELPY led indicating device operation status Normal operation no alarm, filer disabled Normal operation no alarm, filer enabled Alarm (or automatic test call) in progress DESCRIPTION Page 4

5 GSM 200 led indicating GSM signal strength No signal Low signal level Medium signal level High signal level Page 5 DESCRIPTION

6 How to use the reset pushbuttons Helpy Quick-TL GSM has two reset pushbuttons: - RESET pushbutton (R in the picture) - internal reset pushbutton (G in the picture) Use of reset pushbuttons: Pressing shortly Allows to interrupt an alarm call. By pressing shortly you get the same result as lifting the handset of the local telephone and entering : * <Password> #. Pressing longer (15 seconds) Allows to reset the device. By pressing longer, Helpy Quick-TL GSM will be re-started with no need to disconnect the power supply. The reset operation does not alert the previously set parameters. DESCRIPTION Page 6

7 Connecting emergency pushbutton AL1 and filter IN1 It is possible to connect (inside the elevator car) voltage free contact pushbuttons or powered pushbuttons. Voltage free contact pushbuttons Connect the filter contact to IN1 terminal and (negative pole). Page 7 DESCRIPTION

8 Powered pushbuttons (12~ 24Vdc) Connect the filter contact to IN1 terminal and (negative pole). Connect the filter contact to IN1 terminal and +12V terminal. DESCRIPTION Page 8

9 WIRING DIAGRAM WITH ACTIVE HANDSFREE TERMINAL IN THE PIT Page 9 DESCRIPTION

10 WIRING DIAGRAM WITH PASSIVE HANDSFREE TERMINAL IN THE ELEVATOR CAR BOTTOM DESCRIPTION Page 10

11 CORRECT OPERATION CHECKLIST 1. PROGRAMMING Access to programming: lift the local telephone handset and dial. You will hear the dialling tone (one longer tone followed by a shorter tone). Program a telephone number for the emergency-call alarm: dial <telephone number>. Record the identification message of the specific elevator (max. 22 seconds), which is meant to contain all necessary information concerning the elevator location: dial, pronounce the message and hang up. To listen again to the previous message, lift the local telephone handset and dial:. Make an external call to check the telephone line presence: dial and digit the telephone number to make a test call. 2. ALARM PROCEDURE CHECK Press the emergency button. The emergency call will be made. 3. ANSWERING AN ALARM -1 st mode: handsfree connection by Handsfree activation code (factory default) Answer by the called party. The voice messages will be heard. Press to speak with the trapped person. -2 nd mode: automatic handsfree connection Answer by the called party. Speak with the trapped person. Remark: you can choose the 1 st or the 2 nd mode with the Handsfree connection mode programming (code 78). Page 11 CORRECT OPERATION CHECKLIST

12 4. RESETTING AN ALARM -1 st mode: reset by End code (factory default) Press to end the alarm. -2 nd mode: automatic reset Hang up or press to end the alarm. Remark: you can choose the 1 st or the 2 nd mode with the Alarm reset mode programming (code 77). In case it should not be possible to stop the alarm procedure remotely (i.e. the entered telephone number is incorrect) simply lift the handset of the local telephone and dial * <Password> # (by factory default: ). CORRECT OPERATION CHECKLIST Page 12

13 PROGRAMMING In the tables below: INST indicates that the programming procedure is allowed for the installer; OPER indicates that the programming procedure is allowed for the operator; factory default values are highlighted in bold. Basic programming BASIC PROGRAMMING ACCESS TO PROGRAMMING EXITING THE PROGRAMMING <INSTALLER or OPERATOR PASSWORD> (by default: ) <INSTALLER or OPERATOR PASSWORD> (by default: ) SOURCE RECEIVER emergencycall button ADEMCO technological alarm USER TELEPHONE NUMBERS (position from 01 to 12) periodic test call - CLI ESSE-TI (X X = telephone number, max. 20 digits) alarm sent alert notification alarm terminated alert notification SMS P100 DELETING TELEPHONE NUMBER (position from 01 to 12) Page 13 PROGRAMMING

14 BASIC PROGRAMMING HANDSFREE CONNECTION MODE ALARM RESET MODE handsfree activation by Handsfree activation code automatic handsfree activation automatic reset alarm reset by End code DATE weekday SUNDAY MONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY SATURDAY (dd) (mm) (yy) TIME (hhmm; from 0000 to 2359) RECORD MESSAGES identification message (22 sec.) courtesy message (22 sec.) (beep) record and hang up LISTEN TO MESSAGES (INST/OPER) identification message courtesy message (listen) INSTALLATION TYPE handsfree terminals only on the roof, in the elevator car, in the elevator car bottom active handsfree terminal also in the pit NO POWER SUPPLY ALARM DEAD BATTERY ALARM disabled alarm from 01 to 99 = enabled alarm with XX minutes delay disabled alarm enabled alarm PROGRAMMING Page 14

15 ADEMCO / P100 PROTOCOL ID ESSE-TI PROTOCOL ID BASIC PROGRAMMING max 10-digits ID: 10-digits ID: [ ] Frequency (days, from 1 to 9; factory default 3) AUTOMATIC TEST DATA Time (hhmm; from 0000 to 2359) Automatic test alarm automatic test disabled automatic test enabled Make a test call manually BUILT-IN HANDSFREE VOLUME (INST/OPER)... (loudspeaker s volume; factory default 3) PIT HANDSFREE VOLUME (INST/OPER)... (loudspeaker s volume; factory default 3) MESSAGES VOLUMES (INST/OPER)... (volume; factory default 2) LISTENING TO PROGRAMMING... (prefix programming code) RESTORING FACTORY DEFAULT Page 15 PROGRAMMING

16 Advanced programming CHANGING THE INSTALLER PASSWORD CHANGING THE OPERATOR PASSWORD ADVANCED PROGRAMMING (old).. (new).. (new) (old).. (new).. (new) Italian English German LANGUAGE French Polish Portuguese Russian Spanish Italy/Switzerland/Portugal/Poland/Bulgaria England Israel TONE DECODER SETTING Greece Austria (digital) Germany France Australia Russia/Hungary Netherlands/Croatia EMERGENCY BUTTON AL1 NORMALLY OPEN/CLOSED EMERGENCY BUTTON DELAY FILTER ACTIVATION (INST/OPER) normally closed normally open (seconds, from 0 to 9; factory default 2) disabled enabled PROGRAMMING Page 16

17 ADVANCED PROGRAMMING FILTER INPUT NC/NO (INST/OPER) ACKNOWLEDGE CODE HANDSFREE ACTIVATION CODE END CODE EXCLUSION CODE HANDSFREE CONNECTION TIME UPON ALARM NUMBER OF CALLS TO THE SAME TELEPHONE NUMBER FOR EACH CALL CYCLE CALL CYCLES FOR TECHNOLOGICAL ALARMS AND TEST CALLS CALL CYCLES FOR EMERGENCY CALLS AUTOMATIC ANSWER CONNECTION TIME AFTER AUTOMATIC ANSWER OFFSET FLOOR MESSAGES normally closed normally open (from 1 to 3 digits; factory default 5) [ ] (from 1 to 3 digits; factory default 0) [ ] (from 1 to 3 digits; factory default 9) [ ] (from 1 to 3 digits; factory default 1) [ ] (minutes, from 2 to 9) (calls, from 1 to 9) (cycles, from 0 to 9; 0 = 10 cycles; factory default 3) (cycles, from 0 to 9; 0 = unlimited) (ring number, from 0 to 9; 0 = disabled; factory default 1) (minutes, from 1 to 9) (offset, from 0 to 9) Page 17 PROGRAMMING

18 ADVANCED PROGRAMMING same behavior as output AI same behavior as output AR RELAY SETTINGS active for mains failure door opener active as long as the emergency alarm progresses active as long as the buttons are pressed RELAY INTERMITTENCE DTMF GENERATOR SETTINGS WITH steady-state intermittent (500 ms ON / 500 ms OFF) DTMF generated by GSM network DTMF generated by autodialer (DTMF duration = X * 50ms) READING GSM SIGNAL LEVEL Listened or read digits Quality 0-12 No signal Low signal Medium signal >24 High signal PROGRAMMING Page 18

19 PROGRAMMING VIA SMS All parameters programmable locally by the local telephone may also be set via SMS. Programming via SMS is possible by any mobile phone or other device supporting SMS. An SMS notifying that programming has been completed will be sent back by the Helpy Quick-TL GSM to the same telephone number that forwarded the programming SMS. WARNING Programming outgoing SMS from the Internet may not be successful if the requested format is not respected. Programming message format Each programming SMS must contain the password, allowing to access programming, and the codes corresponding to the desired settings. The message format is required to be as follows: ET-HL3 *xxx# n n n n n n Where: ET-HL3 : programming string start *xxx# : password string (default xxx = 0) n n : programming code (e.g. to enable battery check: 521). To set more than one parameter, enter the related codes in a sequence separated by a space, make sure you do not overcome the max number of characters allowed by a single SMS ( 160 characters). Notification message format SMS settings are acknowledged with return SMS generated by Helpy Quick- TL GSM saying which parameter is set. The acknowledge SMS is returned as soon as the setting SMS is received. The message format is required to be as follows: IP DTv DTv DTv OP Where: IP : programming access acknowledge (In Prog) DTv: : string setting acknowledge (v = setting) OP : programming exit acknowledge (Out Prog). Page 19 PROGRAMMING VIA SMS

20 In case a telephone number has been programmed, the string setting will have the following format: DTaNbNy y Where: a: source b: receiver y y: telephone number In case a wrong setting has been entered, the acknowledge string ER will be returned. In case the password is wrong, you will receive the acknowledge string RL ER followed by as many ER as the sent codes are. Remark: settings may be displayed fully or partially in the acknowledge SMS returned after programming, depending on the characteristics of the SMS recipient devices. Examples Desired settings: - date: Thursday 04/02/16 - hour: automatic test call: enabled Programming message: ET-HL3 *0# Notification message: IP DT DT2115 DT1 OP Desired settings: - phone number in the first location associated with Emergency call (source) under User mode (receiver) - phone number in the second location associated with Automatic test call (source) under Esse-ti protocol mode (recipient) Programming message: ET-HL3 *0# # # Notification message: IP DT1N2N DT3N3N OP PROGRAMMING VIA SMS Page 20

21 USE In the tables below: : lift the local telephone handset; : lift the local telephone handset and dial to access programming. Local CONVERSATION WITH THE CAR CONVERSATION WITH ONE HANDSFREE TERMINAL OUTGOING CALLS LOCAL USE CONVERSATION HANDSFREES IN ELEVATOR CAR PIT ACTIVE HANDSFREE DEACTIVATE ALL <TELEPHONE NUMBER> RELAY Remote use with Helpy Quick-TL GSM in stand-by Call Helpy Quick-TL GSM and wait for the answer. After a short series of DTMF tones followed by the elevator identification message, dial: <INSTALLER OR OPERATOR PASSWORD> (by default: ). Besides the programming, the following services are available: REMOTE USE WITH HELPY QUICK-TL GSM IN STAND-BY HANDSFREES IN ELEVATOR CAR CONVERSATION WITH ONE HANDSFREE TERMINAL PIT ACTIVE HANDSFREE DEACTIVATE ALL DOOR OPENER RELAY Page 21 USE

22 NOTE NOTE Page 22

23 Page 23 NOTE

24 Esse-ti s.r.l. Via G. Capodaglio, Recanati (MC) ITALY Tel Fax support@esse-ti.it

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V 05/06/2018 DESCRIPTION Autodialer to be fitted behind the cop or on top of the car / retrofit. A Connector for Esse-ti power supply (12 Vdc) B Micro SD Card

More information

HELPY CONTROLLER QUICK GUIDE

HELPY CONTROLLER QUICK GUIDE Alarm system for elevators compliant with the European Standard EN 81-28:2018 HELPY CONTROLLER QUICK GUIDE 05/04/2019 DESCRIPTION Autodialer specifically designed for installation on elevator controller.

More information

Memcom Emergency Telephone

Memcom Emergency Telephone Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming

More information

Memcom + Emergency Telephone

Memcom + Emergency Telephone Memcom + Emergency Telephone Installation Guide Ref No. 453 901AU (GB) Version 4 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based

More information

AVCOM System Installation Instructions

AVCOM System Installation Instructions AVCOM System Installation Instructions Index 1) AVCOM EN-1 System Drawings - AVCOM EN1 System.. Page 1 - AVCOM EN1 with 2COP.. Page 2 - AVCOM EN1 FF System.. Page 3 -AVCOM EN1 Evacuation System Page 4

More information

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once. Table of Content 1.1General Description----------------------------------------------------------------------2 2.2System Setup-----------------------------------------------------------------------------3

More information

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock. Preface Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock. The GSM Security Alarm ( The Alarm ) adopts the most advanced

More information

DYGIZONE GJD910 Lighting Controller & Enunciator

DYGIZONE GJD910 Lighting Controller & Enunciator DYGIZONE GJD910 Lighting Controller & Enunciator MASTER WIRING IDENTIFICATION Power up to the DygiZone and you will see: All the LED s (red,yellow,green and blue buttons) will flash All the LCD icons will

More information

The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70

The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70 The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70 1. Identify the Equipment and carry out a Risk Assessment before installation AD1000EN- 1R Main Unit EN1 Speaker

More information

MOBILE CALL GSM Alarm System User s Manual

MOBILE CALL GSM Alarm System User s Manual MOBILE CALL GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents Function Introduction (3) Alarm Host Diagram

More information

Basic Installation Manual

Basic Installation Manual SAR SAR-V.7 Program or Higher Alarm Equipment for Lifts Basic Installation Manual in HIDRA System controllers Revision 0 (EN) NOTES FROM THE MANUFACTURER Carlos Silva SA shall not be responsible for any

More information

1. Introduction. 2. Product overview

1. Introduction. 2. Product overview 1. Introduction The AG400011 GSM Alarm panel is a control panel that is compatible with other H-net security devices from Everspring, such as wireless sensors, remote keyfobs, tags, and keypad. With this

More information

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using. V1.0 Smart Home Alarm System User Manual APP download via QR Code scanning Please read the manual carefully before using. Content FUNCTION PROFILE 2 THE SCHEMATIC GRAPH OF HOST 3 PROCESS OF BOOTING 6 OPERATION

More information

GSM RFID VOICE Alarm System

GSM RFID VOICE Alarm System GSM RFID VOICE Alarm System User s Manual For a better understanding of this product, please read this user manual thoroughly before using it. CONTENTS [Function Instruction] [Control Panel] Control Panel

More information

Voice Board. Installation and Programming Guide. Runner 4/8,PowerWave 4/8/16 &, Elite64. Add-on Board For Storing Recorded Voice Messages

Voice Board. Installation and Programming Guide. Runner 4/8,PowerWave 4/8/16 &, Elite64. Add-on Board For Storing Recorded Voice Messages ELECTRONIC ENGINEERING LTD. Voice Board Runner 4/8,PowerWave 4/8/16 &, Elite64 Add-on Board For Storing Recorded Voice Messages And listen-in. Installation and Programming Guide. P/N 7101372 Rev. C V.K

More information

ADE Gen4. Speech Dialler Engineering Information. Description. Features

ADE Gen4. Speech Dialler Engineering Information. Description. Features ADE Gen4 Speech Dialler Engineering Information Description The Informa is a Speech Dialler for use with intruder alarm systems. When the control panel recognises an alarm it triggers the Informa. The

More information

IP & SMS Alarm Communicator

IP & SMS Alarm Communicator Models: WGSMSC You deserve to feel safe, secure & protected IP & SMS Alarm Communicator Quick Start Guide Thank you for purchasing a Watchguard IP & SMS Alarm Communicator This Quick Start Guide covers

More information

1. User features of the GSM dialer

1. User features of the GSM dialer 1. User features of the GSM dialer The JA60GSM dialer offers many useful features described in detail below. The installer should properly demonstrate the use of the system to the user after installation

More information

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

Profile. For a better understanding of this product, please read this user manual thoroughly before using it. Intelligent GSM Auto-Dial Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents Function Introduction (3) Alarm

More information

1. Functions of GPS locator ETLOC-30S 3

1. Functions of GPS locator ETLOC-30S 3 Contents 1. Functions of GPS locator ETLOC-30S 3 1.1 Direct view of the vehicle position on the map 3 1.2 Vehicle security 3 1.2.1 Vehicle protection 3 1.2.1.1 GPS protection 3 1.2.1.2 GPS higher level

More information

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard. COMMUNICATOR ET08 User Manual v1.0 Safety instructions Please read and follow these safety guidelines in order to maintain safety of operators and people around: GSM communicator (gateway) ET08 (further

More information

EA-MINI / EA-MINI-V. LEITRONIC AG Swiss Security Systems

EA-MINI / EA-MINI-V. LEITRONIC AG Swiss Security Systems 4923 Table of contents Overview... 2 2 Applications... 3 2. Door-phone... 3 2.. Wiring... 3 2.2 Alarm dialler... 4 2.2. Wiring... 4 3 Mechanical fitting... 5 3. Retrofit solutions to existing elevators...

More information

ANEP S-BOX EMERGENCY TELEPHONE FOR ELEVATORS.

ANEP S-BOX EMERGENCY TELEPHONE FOR ELEVATORS. ANEP S-BOX EMERGENCY TELEPHONE FOR ELEVATORS www.anepanywhere.com SUMMARY 1 - TECHNICAL CHARACTERISTICS Page 4 1.1 - Technical characteristics 1.2 - Machine room Intercom and fireman until functionnality

More information

AD1000EN-1R configured to operate as a DG1000

AD1000EN-1R configured to operate as a DG1000 AD1000EN-1R configured to operate as a DG1000 Install the Main Unit on top of the lift car and mount the Microphone in the COP. Mount the Plastic speaker box so the speaker holes align up with some holes

More information

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual Page 1 Warning Do not remove the front or back cover of the unit and keep it intact. There are no parts inside this unit that can be repaired

More information

Version 1.03 January-2002 USER S MANUAL

Version 1.03 January-2002 USER S MANUAL Version 1.03 January-2002 1 USER S MANUAL 2 Version 1.03 January-2002 System Details CUSTOMER:...... PHONE:... FAX:... INSTALLED BY:...... PHONE:... FAX:... MAINTENANCE & SERVICE:...... PHONE:... FAX:...

More information

Intelligent Wireless GSM Alarm System

Intelligent Wireless GSM Alarm System Intelligent Wireless GSM Alarm System 00M2K User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents [Function Instruction] [Alarm

More information

ProCom The App for Alarm Systems in the Protect Series Operating Manual

ProCom The App for Alarm Systems in the Protect Series Operating Manual ProCom The App for Alarm Systems in the Protect Series Operating Manual Contents Before You Start........................................... 4 Read the Operating Manual....................................

More information

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice. BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice. via Florida Z.I. Valtesino - 63013 GROTTAMMARE (AP) - ITALY Installation and Quick guide: DUAL

More information

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n SW version 5.n PORTAL USER MANUAL Mobeye WaterGuard-FS Float sensor CM2300FS Attention! Very important This user manual contains important guidelines for the installation and usage of the Mobeye device

More information

GSM AUTO DIALLER WIRELESS ALARM SYSTEM MODEL AD-SD MODEL AD-SD-W www.gsm-activate.co.uk Model AD-SD & Model AD-SD-W PAGE 1 Product Information Our AD-SD Auto Dialler is a versatile unit which can be attached

More information

DX2002 OPERATING AND PROGRAMMING INSTRUCTIONS

DX2002 OPERATING AND PROGRAMMING INSTRUCTIONS DX2002 OPERATING AND PROGRAMMING INSTRUCTIONS The four pushbuttons located at the bottom right of the circuit board are used to do all programming. Each button has more than one function. Alternate Settings

More information

Mobeye CM2410 GSM fire alarm communicator

Mobeye CM2410 GSM fire alarm communicator PORTAL USER MANUAL Mobeye CM2410 GSM fire alarm communicator Accessory for Ei Electronics fire detector SW version 5.n Incl. CM2400 Attention! Very important This user manual contains important guidelines

More information

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. SK618 WIRELESS ALARM SYSTEM WITH AUTO DIALER OWNER'S MANUAL Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. If at any time during your installation you have any questions

More information

GSM 3G AUTO DIALLER PLUS

GSM 3G AUTO DIALLER PLUS GSM 3G AUTO DIALLER PLUS Control and Monitoring from your mobile phone www.gsm-activate.co.uk MODEL NUMBER 3GADV2 Page 1 Contents 2 3 - Contents. - Product Information. - Specification. 4 5 - PCB Reference.

More information

EXICALL EN70 EXICALL EN70MR EXICALL EN70-ATEX

EXICALL EN70 EXICALL EN70MR EXICALL EN70-ATEX LEITRONIC AG Swiss Security Systems ELEVATOR EMERGENCY DIALLER EXICALL EN70 EXICALL EN70MR EXICALL EN70-ATEX Issue: 18 August 011 1. Door phone (EXICALL EN70) EN81-70 emergency button Center> 90cm (

More information

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. SK618 WIRELESS ALARM SYSTEM WITH AUTO DIALER OWNER'S MANUAL Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. If at any time during your installation you have any questions

More information

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.

More information

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master) User Codes (1-6 digits) Access Levels Access Levels + Time Control User 1 (Master) 1 1 2 3 25 49 73 0 User 2 2 26 50 74 0 User 3 3 27 51 75 0 User 4 4 28 52 76 0 User 5 5 29 53 77 0 User 6 6 30 54 78 0

More information

Burglar-alarm unit. User manual. Part. U3499A - 11/08-01 PC

Burglar-alarm unit. User manual. Part. U3499A - 11/08-01 PC Burglar-alarm unit User manual 5739 34 5739 35 Part. U3499A - 11/08-01 PC Contents 1. Introduction 5 The Burglar-alarm Unit 6 The keypad 7 Navigation keys 7 The display 7 Initial page 7 In case of an

More information

Programming the Vi+ using a Series Telephone. Tunstall Vi+

Programming the Vi+ using a Series Telephone. Tunstall Vi+ Tunstall Vi+ Programming the Vi+ using a SeriesTelephone Your Vi+ Page 2 Ver 1 4/24/2015 Programming a telecare sensor to the Vi+ Telecare sensors with plug and play functionality can be programmed to

More information

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY. SK642 WIRELESS WATER ALARM SYSTEM WITH AUTO DIALER OWNER'S MANUAL AND SET UP INSTRUCTIONS. Thank you for choosing Ideal Security s Wireless Water Alarm with Telephone Dialer. Please read through complete

More information

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System MOBILE CALL GSM Alarm System USER S MANUAL System disarmed 00/00/00 00:00 ARM STAY CALL 1 2 3 4 5 6 7 8 9 Power Set Signal Alarm SOS ESC 0 ENTER Profile For a better understanding of this product, please

More information

Burglar Alarm System Manual Model: BAS- N

Burglar Alarm System Manual Model: BAS- N . Contents Burglar Alarm System Manual Model: BAS- N Make sure you get a printed Index made from the installer & paste the same behind Keyboard panel. We extend a warm welcome to you on becoming a part

More information

USER & INSTALLATION GUIDE

USER & INSTALLATION GUIDE Reach Plus At Home Alarm Unit Touch Personal Pendant USER & INSTALLATION GUIDE www.tynetec.co.uk SECTION 1 USER INSTRUCTIONS Section Topic Page 1.1 Important Information 3 1.2 Unpacking the Reach Plus

More information

User Manual (LS-GSM-006)

User Manual (LS-GSM-006) GSM Home/Business Alarm System User Manual (LS-GSM-006) Profile For a better understanding of this product, please read this user manual thoroughly before using it. - 1 - Catalogue: Function Introduction

More information

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual WIC-16Z4P WIC-5Z2P Installation & Operation User Manual Page : 1/34 INDEX # Function Page 1 Abort Current Communication and Clear Reporting Queue (*59) 13 2 Abort Current Communications (*59) 10 3 Account

More information

COMMUNICATOR ET08 / ET081

COMMUNICATOR ET08 / ET081 COMMUNICATOR ET08 / ET081 User Manual v1.2 Safety instructions Please read and follow these safety guidelines in order to maintain safety of operators and people around: GSM communicator ET08 / ET081 (further

More information

System. For a better understanding of this product, please read this user manual thoroughly before using it.

System. For a better understanding of this product, please read this user manual thoroughly before using it. GSM Alarm System User s Manual For a better understanding of this product, please read this user manual thoroughly before using it. Chapter 1. Features Chapter 2. Control Panel Introduction Chapter 3.

More information

2G & 3G GSM Door Contact Alarm

2G & 3G GSM Door Contact Alarm 2G & 3G GSM Door Contact Alarm www.gsm-activate.co.uk MODEL RF - PIR PAGE 1 Product Information Our 2G/3G GSM Door Contact Alarm is a standalone alarm system for smaller rooms inside properties. It will

More information

GSM 3G AUTO DIALLER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

GSM 3G AUTO DIALLER. Remote monitoring & Control using your mobile phone.   MODEL NUMBER 3GAD1 GSM 3G AUTO DIALLER Remote monitoring & Control using your mobile phone www.gsm-activate.co.uk MODEL NUMBER 3GAD1 PAGE 1 Product Information Our GSM 3G Auto Dialer is a versatile unit which can be attached

More information

Contents. Contents

Contents. Contents Contents Contents-----------------------------------------------------3 Preface-------------------------------------------------------------------4 Function Introduction-------------------------------------------------5

More information

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System MOBILE CALL GSM Alarm System GSM Alarm System System disarmed 11/26/2013 User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. CONTENTS

More information

BURGLAR ALARM PANEL BS-468

BURGLAR ALARM PANEL BS-468 BURGLAR ALARM PANEL BS-468 Contents 1. Description... 3 2. Instructions for the user... 4 2.1Basic operations... 4 Complete system.... 4 Split system.... 4 2.2 Armed system indication... 5 2.3 Advanced

More information

reading carefully this guide, operating this system strictly on the standard procedure.

reading carefully this guide, operating this system strictly on the standard procedure. SYSTEM-ZDAS-16CA-8 PROGRAMMING GUIDE Thanks for choosing ZDAS-16CA-8 Multi-Function Alarm Control Panel. We suggest you reading carefully this guide, operating this system strictly on the standard procedure.

More information

EC II GSM SE User Manual

EC II GSM SE User Manual EC II GSM SE User Manual 1 Table of contents 1 TABLE OF CONTENTS...2 2 NOTES AND DISCLAIMER...5 3 COPYRIGHT...5 3.1 Description of goods... Fehler! Textmarke nicht definiert. 3.2 Warranty...5 3.3 Updates...5

More information

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone.   MODEL NUMBER 3GAD1 3G GSM AUTO DIALER Remote monitoring & Control using your mobile phone www.gsm-activate.co.uk MODEL NUMBER 3GAD1 PAGE 1 Product Information Our 3G GSM Auto Dialer is a versatile unit which can be attached

More information

D3D Wi-Fi GSM Smart Alarm System -User Manual

D3D Wi-Fi GSM Smart Alarm System -User Manual D3D Wi-Fi GSM Smart Alarm System -User Manual D3D Wi-Fi / GSM Smart Alarm system (Model : D10). Please read all instructions carefully & follow steps for easy home installation. 1 P a g e D3D Wi-Fi / GSM

More information

Installation manual: CA-1803BT Athos mode 1 for cars without an original remote control for central locking

Installation manual: CA-1803BT Athos mode 1 for cars without an original remote control for central locking Installation manual: CA-1803BT Athos mode 1 for cars without an original remote control for central locking Main features for this mode: Remote control of car central locking (if installed) via a remote

More information

HIDRA CRONO Controller

HIDRA CRONO Controller HIDRA CRONO Controller SAR pluscom Alarm equipment for lifts Installation guide ENGLISH DC83501Q00 *DC83501Q00* Release 2b NOTE FROM THE MANUFACTURER Carlos Silva SA shall not be responsible for any claims

More information

Destiny Destiny Owners Manual

Destiny Destiny Owners Manual Destiny 4100 Destiny 4100 Owners Manual TABLE OF CONTENTS INTRODUCTION Control Panel...3 Detection Devices...3 Telephone Keypads...3 GLOSSARY... 4-5 LOCAL PHONE ACCESS Using Your Telephones As Keypads...6

More information

2G & 3G GSM Wireless Beam Alarm

2G & 3G GSM Wireless Beam Alarm 2G & 3G GSM Wireless Beam Alarm www.gsm-activate.co.uk MODEL RF - BEAM PAGE 1 Product Information Our 2G/3G GSM Wireless Beam Alarm is a standalone alarm system suitable for indoor and outside use. It

More information

USER MANUAL Mobeye ThermoGuard CM2200

USER MANUAL Mobeye ThermoGuard CM2200 USER MANUAL Mobeye ThermoGuard CM2200 SW version 1.n Attention! Very important This user manual contains important guidelines for the installation and usage of the Mobeye device as described in this manual.

More information

2G & 3G GSM Portable PIR Alarm

2G & 3G GSM Portable PIR Alarm 2G & 3G GSM Portable PIR Alarm www.gsm-activate.co.uk MODEL RF - PORTABLE-PIR PAGE 1 Product Information Our 2G/3G Portable PIR Alarm is a standalone alarm system suitable for indoors or outside usage.

More information

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor A1UL PERS Personal Emergency Response System TABLE OF CONTENTS 1. READ THIS FIRST... 1 2. SYSTEM OVERVIEW.. 1 3. COMPONENTS 2 4. UNIT OPERATION! Standby Mode.. 3! Emergency Activation. 3! Answering Incoming

More information

l 02-April-2010 For INSTANT CARE

l 02-April-2010 For INSTANT CARE l 02-April-2010 For INSTANT CARE Table of Contents 1. Application Overview 1 1.1. Identifying The Parts 1 1.2. The Power Supply 3 1.3. Line Capture 3 1.4. Line Failure Detection 4 1.5. How to install the

More information

EM8710 GSM Alarm System Starter Kit

EM8710 GSM Alarm System Starter Kit EM8710 GSM Alarm System Starter Kit EM8710 - GSM Alarm System Starter Kit 2 ENGLISH Table of contents 1.0 Introduction... 3 1.1 Packing contents... 4 2.0 Explanation of the Alarm system... 5 2.1 Front...

More information

ANEP BOX - TA EMERGENCY TELEPHONE AND INTERCOM SYSTEM FOR LIFTS EMERGENCY TELEPHONE FOR LIFTS.

ANEP BOX - TA EMERGENCY TELEPHONE AND INTERCOM SYSTEM FOR LIFTS EMERGENCY TELEPHONE FOR LIFTS. ANEP BOX - TA EMERGENCY TELEPHONE FOR LIFTS EMERGENCY TELEPHONE AND INTERCOM SYSTEM FOR LIFTS www.anepstore.com SUMMARY 1 - TECHNICAL CHARACTERISTICS Page 4 1.1 - Technical characteristics 1.2 - Machine

More information

Computer Room Guard Model VM Manual and Installation Instructions

Computer Room Guard Model VM Manual and Installation Instructions Computer Room Guard Model VM500-8 Manual and Installation Instructions For units purchased since December 2004 Index Page General Description 3 Installation, Wiring Diagram 3-5 Accessing the Computer Room

More information

AT60 AUTO DIALLER User Guide

AT60 AUTO DIALLER User Guide AT60 AUTO DIALLER User Guide Power on LED MIC Power on LED MIC 1 2 3 4 5 6 7 8 9 REC/PLAY 0 STORE M1 M2 M3 Table of Contents I. Overview 3 II. Installation 4 III. Initialize the Dialer 5 IV. Using the

More information

Vcare. User Manual. Ver WiFi - GSM- App. Smart Home Security System

Vcare. User Manual. Ver WiFi - GSM- App. Smart Home Security System Vcare User Manual Ver.20161126 WiFi - GSM- App Smart Home Security System Tips:. Carefully read through this user manual prior to installation. Keep the user manual in a safe place for future reference

More information

Security GSM Alarm System

Security GSM Alarm System Security GSM Alarm System USER MANUAL 4 wired and 6 wireless defense zones; Can preset and store 6 voice phones and 3 message phones; Remote two-way intercom; Telephone (mobile phone) remote control programming;

More information

Ref.1067/032 Ref.1067/042

Ref.1067/032 Ref.1067/042 DS1067-033A Mod. 1067 LBT8631 BUS CONTROL PANEL 8/32 INPUTS Ref.1067/032 Ref.1067/042 USER MANUAL TABLE OF CONTENTS 1 PREFACE... 5 2 COMMAND DEVICES... 6 2.1 1067/021 DISPLAY KEYPAD... 6 2.2 ELECTRONIC

More information

AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL

AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL M 890-00279 rev. 14 K 895-00004 rev. 00 Manufacturer: Viatron Electronics 5200, Armand-Frappier St-Hubert (Quebec) Canada J3Z 1G5 WARNINGS The warranty can be void

More information

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System By shield4u http:// (Version 20110816) A. Alarm Understanding Away Disarm Home Emergency Function Signal Interpretation Buzzer

More information

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP PROGRAMMING STARTS Entering Installer mode If you want to get into program mode press followed by your installer code, default set to 000000

More information

EasyAlarm ELEVATOR LEITRONIC AG

EasyAlarm ELEVATOR LEITRONIC AG LEITRONIC AG Swiss Security Systems ELEVATOR EMERGENCY DIALLER BROCHURE EasyAlarm ELEVATOR Independent elevator emergency call by Swiss market leader can be installed / operated by any elevator company

More information

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom CC880/LP880, SC8016 EN Operators Guide Solution-16, Solution-16 Safecom CC880/LP880, SC8016 Operators Guide EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch

More information

It is necessary to match all peripherals with the EVOLVEO Alarmex main unit before the first use. For safety reasons, they are not factory paired.

It is necessary to match all peripherals with the EVOLVEO Alarmex main unit before the first use. For safety reasons, they are not factory paired. Thank you for purchasing the GSM alarm system EVOLVEO Alarmex. Please, read this user manual carefully and follow strictly the set instructions. This product uses the most modern technology, yet you cannot

More information

Careline Anna Careline GSM

Careline Anna Careline GSM Careline Anna / Careline GSM Programming and installation manual List of contents 1 Introduction... 3 1.1 General description of Careline Anna/GSM... 3 1.2 General description of Tx4 alarm transmitter...

More information

Wireless Alarm system s manual

Wireless Alarm system s manual MOUNTVIEW TECH AUSTRALIA PTY LTD Wireless Alarm system s manual ADS ECO GSM320 Series ADS Security 1/11/2011 1. Before You Begin For your safety and the safety of others, and to ensure that you get the

More information

WiFi GSM APP Smart Home Security System

WiFi GSM APP Smart Home Security System User Manual WiFi GSM APP Smart Home Security System Tips: Please read through this user manual before installation so as to operate properly. Please keep well of the user manual for further reference.

More information

CEM-24 Series. Owner's Manual - Installation and Operating Instructions

CEM-24 Series. Owner's Manual - Installation and Operating Instructions CEM-24 Series Owner's Manual - Installation and Operating Instructions Rev. 6.4 01.10 Pipersville, PA 18947 USA Phone: (215) 766-1487 - Fax: (215) 766-1493 Email: support@scillc.com - www.scillc.com Please

More information

Contents. Glossary

Contents. Glossary Contents Glossary ------------------------------------------------------------------------------------------------------ 6 1. Introduction to the IDS 1632 -------------------------------------------------------------

More information

Smart GSM/GPS car alarms

Smart GSM/GPS car alarms Smart GSM/GPS car alarms Control CA-1802 and CA-1803 Athos Guarding Communication User manual Accessories 4453 - Jablotron - Manuál Athos - EN.indd 1 18.5.2010 9:25:34 Contents 1 Car alarm control... 3

More information

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation TYDOM 5 GSM domotics transmitter ) Présentation. Presentation Delta Dore hereby declares that the equipment complies with the essential requirements and other relevant provisions of the R&TTE Directive

More information

DiaLog Elite. Quick Reference Guide. Remote Monitoring, Control and. Alarm Notification System. # Enter. 1 Prog. 2 Run. 5 SpkrPh. Ack. Arm.

DiaLog Elite. Quick Reference Guide. Remote Monitoring, Control and. Alarm Notification System. # Enter. 1 Prog. 2 Run. 5 SpkrPh. Ack. Arm. DiaLog Elite 1 Prog Remote Monitoring, Control and 2 Run Alarm Notification System 5 SpkrPh 0 Status # Enter Quick Reference Guide Ack Clear Arm Reset Disarm Bksp Home Antx, inc. 2008 RUN Mode Commands

More information

MEDI-CALL UNIT INSTALLATION MANUAL. Medi-Call V2.0 - V2.7 Installation Manual

MEDI-CALL UNIT INSTALLATION MANUAL. Medi-Call V2.0 - V2.7 Installation Manual MEDI-CALL UNIT INSTALLATION MANUAL Medi-Call V2.0 - V2.7 Installation Manual Copyright SmartLink International Pty Ltd February 2006 475 Nepean Highway, Brighton VIC 3186 Australia Telephone: +61 3 9596

More information

NEO IP/GSM Technical Handbook

NEO IP/GSM Technical Handbook NEO IP/GSM Technical Handbook NE41 09002-02 v2.0 Copyright 2011 Neat Electronics AB Revision date: 2011-12-19 NEAT Electronics AB Varuvägen 2 SE-246 42 Löddeköpinge Sweden Phone: +46 46 70 70 65 Fax: +46

More information

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone! Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone! GSM SMS Controller DCS-130 User Manual Ver 1.20 Date Issued: 14-9-2010

More information

Specialists in communications for the elevator industry

Specialists in communications for the elevator industry Specialists in communications for the elevator industry CATALOGUE 2017-2018 MERak - 1 Index of Contents MERak: Safety first MERak R&D MERak devices and EN 81-28 standard EMERGENCY TELEPHONES MEP2L Land

More information

User instructions EasyAlarm CONTROL

User instructions EasyAlarm CONTROL LEITRONIC AG Swiss Security Systems TELEMONITORING / TELECONTROLLING SYSTEM User instructions EasyAlarm CONTROL Interface-Modul Potential free relay switch: 10..230V AC or DC AC-switch: max. 2A / 230V

More information

SC-F3G User Manual 1.0

SC-F3G User Manual 1.0 SC-F3G User Manual 1.0 Table of Contents 1. Introduction... 3 2. Functions... 3 3. Features... 3 4. Package Contents... 3 5. Device Configuration... 4 6. Status LED signals... 5 7. Before You Start...

More information

Ontech GSM 9040/50. Reference Manual English -1 -

Ontech GSM 9040/50. Reference Manual English -1 - Ontech GSM 9040/50 Reference Manual English -1 - Content Welcome... 5 This manual... 5 Text styles... 5 Support... 5 Disclaimer... 5 Overview... 6 Accessories... 6 External temperature sensor 9901... 7

More information

PiSector GSM Cellular Wireless Alarm System

PiSector GSM Cellular Wireless Alarm System PiSector GSM Cellular Wireless Alarm System User Manual ( GS08 ) Read manual fully before use. PiSector Inc., USA, www.pisector.com Welcome to PiSECTOR Thank you for choosing PiSECTOR. Everyone at PiSECTOR

More information

GLOBAL. InstallatIon & operation manual

GLOBAL. InstallatIon & operation manual InstallatIon & operation manual INDEX 1. INTRODUCTION... 5 2. FEATURES AND FUNCTIONS 2.1 Reporting Options... 2.2 Interfaces... 2.3 Programming... 2.4 Indicators and Controls...... 6 6 6 6 6 3. INSTALLATION...

More information

PERMACONN PM1030 Includes DI300. Installation Manual

PERMACONN PM1030 Includes DI300. Installation Manual PERMACONN PM1030 Includes DI300 Installation Manual Radio Data Comms Unit 5/20-30 Stubbs Street Silverwater NSW 2128 Telephone: 02 9352 1777 Facsimile: 02 9352 1700 Introduction The PERMACONN system provides

More information

Elderly Care Alarm System

Elderly Care Alarm System Introduction 24/7 Peace of mind for your family The GSM Elderly Care Alarm System is a new released smart solution for take care of senior, aged, elder or disabled people on their daily life. Big LED display

More information

DS7446KP. User Guide. Keypad

DS7446KP. User Guide. Keypad DS7446KP EN User Guide Keypad DS7446KP User Guide Command Quick Reference Command Quick Reference Command Type Basic Arming Commands Advanced Arming Commands System Disarming Commands Command Turn the

More information

Refrigerator/Freezer Guard Models VM605, VM605E. Property Guard Models VM610, VM610E. Temperature Monitor and Alarm

Refrigerator/Freezer Guard Models VM605, VM605E. Property Guard Models VM610, VM610E. Temperature Monitor and Alarm Refrigerator/Freezer Guard Models VM605, VM605E Property Guard Models VM610, VM610E Temperature Monitor and Alarm Microtechnologies, Inc. www.temperatureguard.com sales@temperatureguard.com support@temperatureguard.com

More information