VISTA 20 UK ENGINEER S MANUAL

Size: px
Start display at page:

Download "VISTA 20 UK ENGINEER S MANUAL"

Transcription

1 VISTA 20 UK ENGINEER S MANUAL AL i

2 ii

3 Contents SECTION 1: WIRING AND SAFETY INFORMATION... 1 General... 1 Siting... 1 Fixing... 1 Ventilation... 1 Cabling... 1 Mains Supply Connections... 2 Cable Type... 3 Fuses... 3 Equipment Electrical Rating... 3 Batteries... 3 SECTION 2: INSTALLING THE VISTA Fixing the Cabinet... 5 Installing The Remote Keypad... 6 Zone Wiring... 7 Programmable Output Triggers... 8 Wiring an Exit Terminate Button (Push-to-Set)... 8 External Bell Connections... 9 Summary of Main PCB Connections Telephone Line Installation Wiring REN Approval SECTION 3: OPTIONAL MODULES Expander Module Addressing DIP Switches Connections Zone Wiring Outputs Status LEDs Relay Module DIP Switch Settings Panel Connections Relay Connections SM Speaker Module iii

4 SECTION 4: PROGRAMMING THE VISTA General Entering / Exiting Program Mode Programming Format Defaults Software Version Programming Fields Entry/Exit Output Options Field *89 programming (Expander Module Addressing) Engineer User Access Rights (Codes) Zone Programming Options Zone Responses Zone Options Communication Downloading Alpha-Numeric Keypad - Text Programming Zone Descriptors...33 Custom Words...33 Library Zone Response Definitions Output Type Definitions SECTION 5: OPERATING THE SYSTEM Setting and Unsetting the System Full Setting the System Part Setting the System Unsetting the System Area Setting Setting the System with a Mains Fail or a Line Fail Resetting After an Alarm Bypassing Zones Programming User Codes Panic Alarm Fire Alarm Duress Chime Testing the system Setting the Time and Date Viewing the Event Log Printing the Event Log Troubleshooting iv

5 APPENDIX A: SPECIFICATIONS Control Panel Full Text Keypad UK Fixed Text Keypad Expander Module Relay Module ADEMCO LIMITED WARRANTY v

6 vi

7 SECTION 1: WIRING AND SAFETY INFORMATION General It is essential that this product is installed correctly, in particular with respect to a persons safety and connection to the mains electricity supply. This product is not suitable for installation, maintenance or connection by the user; installation and maintenance must be carried out by a competent, qualified installer, for example, BS5750 or NACOSS approved. It is a condition of the product s approval that the installer complies with the following: Siting The control panel must be sited indoors in a secure area where it cannot be readily interfered with. The location must have adequate ventilation, ample light and easy access for servicing and maintenance. It is not suitable for siting externally or in harsh environments where it could be subject to high humidity, extremes of temperature, chemical atmospheres, high dust levels, or in a position where it may be subject to dripping or splashing by water or other fluids. Fixing The control must be securely fixed to a vertical, smooth, solid surface which is part of the fabric of the building. The position chosen must allow the cabinet door to be removed and allow unhindered access for installation and maintenance. Ventilation While the control panel has been designed so that no part reaches an unsafe temperature it is important that adequate ventilation is provided around the cabinet. Heatradiating equipment or sources of heat should therefore not be positioned close to the cabinet. Cabling The product has high voltage barriers between the mains supply (excessive voltage), the alarm wiring terminals (separated extra low voltage) and the telephone line terminals (telecom network voltage). It is essential that these barriers are maintained in the way the cables enter the cabinet, are routed inside the cabinet and are routed externally. Knockouts, rear entry points and a trunking point are provided for cable entries; additional holes must not be cut in the enclosure. Where necessary, the cable must be protected at the entry point by the use of grommets. The cables external to the cabinet must be either firmly affixed to the fabric of the building using suitable clips or saddles or mechanically protected in conduit or trunking. Alarm system cables must 1

8 not be allowed to loop inside the cabinet they must be neatly trimmed. It must not be possible to put strain on the wiring within the control cabinet by pulling on cables external to the cabinet. Knockouts or the trunking entry point must only be removed if cables are to enter the cabinet at that point. The hole must be covered by the trunking or conduit or by means of a blanking grommet. It must not be possible to push a finger or similar size object or instrument into any hole or cable entry point. Mains Supply Connections Note: This apparatus must be earthed. The connection to the a.c. mains supply must be made by a competent, qualified person, e.g. NICEIC approved, in accordance with the current IEE and local supply regulations. The earth impedance of the mains input earth must be verified. A means of isolation from the mains supply must be provided within 2 metres of the control. This is normally a switched fused spur fitted with a 3 A fuse. Where a flexible cable is connected to the control panel having cores coloured green/ yellow, brown and blue, it is important to connect the wires according to the following code: Green/yellow: Earth connect to terminal marked E Blue: Neutral connect to terminal N Brown: Live connect to terminal L Where a non-flexible cable is connected to the control having cores coloured red, black, and a green/yellow sleeve covering the earthing conductor, it is important to connect the wires according to the following code: Green/yellow: Earth connect to terminal marked E Black: Neutral connect to terminal N Red: Live connect to terminal L The insulation of each conductor must be prepared and connected so that no part of the bare conductor is visible or protruding outside the terminal block. In the case of standard conductors, all the strands should be twisted together and firmly clamped in the terminal. Each of the wires must be cut to a length such that if the cable slips out of the cable clamp and is strained, the live conductor will become taut before the conductor that is connected to the protective earth terminal. The outer covering insulation must be clamped under the cable clamp provided. It is important that this cable enters the control panel enclosure through the mains entry hole provided, is not looped within the control panel enclosure and does not run close to other system cables inside or external to the enclosure. The cover of the control panel enclosure must not be opened before isolating the mains supply. The green Power LED indicates the presence of a.c. mains supply. The cover must be securely fitted in normal use. 2

9 Cable Type The conductors of the mains supply cable must have a minimum cross-sectional area of 0.75 mm and the insulating material on each conductor must be a minimum of 0.4 mm thick Polyvinyl Chloride (PVC). Flexible cables must conform to the requirements of BS6500 and IEC Publication 227. Non flexible electrical installation cables must conform to BS6004 and the earth continuity conductor must be covered with a green/yellow sleeve where it leaves the outer sheath. Fuses The mains fuse within the cabinet is rated at 2A. The mains supply must be disconnected before opening the cabinet and changing the fuse. Replace mains fuse with the same type and rating, that is: Rating: 2A anti-surge (T). Construction: Glass or ceramic (sand filled) cartridge. Dimensions: 25 mm length, 5 mm diameter. Conformance: BS EN and IEC Equipment Electrical Rating The control equipment is designed to operate on a UK mains supply of 230 Volts a.c. at a frequency of 50 Hz (230 V +10% 6%, as stated in the IEE publication Commentary on BS7671:1992 Requirements for Electrical Installations). It is not suitable for other types of supply. The maximum current consumption in normal use is 80 ma. Batteries The battery used with the control panel must be a 12 V sealed lead-acid rechargeable battery of up to 7.2 Amp-hour capacity. The battery must be positioned on the battery shelf. The battery leads must be connected to the battery observing the polarity and not allowed to hang near the mains terminal block. 3

10 4

11 SECTION 2: INSTALLING THE VISTA 20 Fixing the Cabinet The enclosure base should be fixed to the mounting surface as follows: 1. Remove the enclosure lid by unscrewing the two fixing screws, sliding the lid upwards past the bottom lip and easing it away from the base. 2. Mark the position of the two mounting holes and keyhole slot on the mounting surface. Knock-out (top) Keyhole slot Bell tamper Output triggers Vista 20 Printed Circuit Board Zone terminals Telephone line Cable entry points Mains fuse Fuse terminal block L E N Transformer Mains entry point Telephone entry point Mounting holes Knock-outs (on underside) Figure 2.1 Enclosure Layout 3. Position the control panel enclosure on the mounting surface using the keyhole slot in the enclosure base. 4. Bring the cabling into the enclosure via the appropriate cable entry points. The entry points for the a.c. mains and telephone cables are marked in Figure 5

12 2.1 Enclosure Layout. Other cabling can be brought in via the four cable entry points on the back-plane or through the knock-outs on the underside and topside of the enclosure. 5. Secure the enclosure base firmly in place using the two mounting holes, 1.5 x No. 8 screws are recommended. It is strongly recommended that toggle or butterfly fixings are used if the mouting surface is a cavity wall. Installing The Remote Keypad A maximum of four remote keypads can be connected to the system. Any of the following keypads can be used: 6128UK fixed text 6128IR fixed text 6139 full text Mounting the Keypad Care should be taken when selecting the mounting location and height of the keypad. The keypads should not be mounted directly under a light source and should be slightly below eye level for optimum viewing. 1. Remove the back case by pressing down the two snaps on the keypads upper edge while carefully pulling the two halves of the case apart. 2. Route the wiring from the control panel through the opening in the back of the case. 3. Attach the back case to the mounting surface. 4. If using the 6139 keypad, plug the supplied flying lead connector into the keypad PCB socket. If using the 6128 keypad, wire the four cores into the 4 way terminal block on the back of the keypad. Wiring the Keypad The Vista 20 PCB has two keypad buses. The bus 1 connections are on the terminal strip on the left side of the board (Data In, Data Out, +12V, 12V). Bus 2 is located to the left of the main processor connector labelled PLC. If the system is programmed for one area only then all keypads should be connected to Bus 1. If the system has two areas (see section on area setting) then the area 1 keypads must be connected to bus 1 and the Area 2 keypads to bus 2 (using the supplied wiring loom). The keypad wiring convention is shown in Table 2.1. The control panel connections refer to either bus 1 or bus 2, depending on whether the keypad is for Area 1 or 2. Control Panel Data Data Out In Keypad 6139 Keypad Data Out Data In Yello w Green + 12V + 12V Red -12V -12V Blac k Table 2.1 Keypad Wiring. Note: A maximum cable run of 300 metres is advised. This is the total length of all keypad cabling for the system.

13 Zone Wiring The standard system supports up to 8 wired zones. These zones are double-pole, normally closed alarm and tamper loops. An additional tamper zone (zone 9) is included on the main board for the external bell tamper. The system can also be expanded to 24 zones - for details see Expansion Module. See Figure 2.2 Zone Wiring for zone 5 and 6 connections Tamper Alarm Tamper Zone 6 Zone 5 Figure 2.2 Zone Wiring Alarm The zones can also be configured for normally open devices. This is done by leaving the alarm and tamper links fitted across the zone terminals and wiring the normally open contacts across the pair of links. This is shown in Figure 2.3 Normally Open Zone Tamper Alarm Normally Open Device Zone 6 Figure 2.3 Normally Open Zone 7

14 Programmable Output Triggers Six programmable output triggers are available on the terminal strip marked PLA. The text adjacent to the strip refers to the default response of each trigger - see Figure 2.4 Output Triggers. These can be reprogrammed as required - see Output Options in programming section. The output polarity defaults to positive removed (negative applied), i.e. the voltage is normally +12V, dropping to 0V when the trigger is active. The polarity can be reprogrammed if required. A maximum current of 5 ma can be drawn from each trigger. FIRE PANIC BURG TAMP FAULT PROG PLA 1 Figure 2.4 Output Triggers Wiring an Exit Terminate Button (Push-to-Set) A momentary Exit Terminate button can be connected to any zone programmed as Push Button Set. If using a normally closed button the contacts should be wired across the alarm contacts of the zone and the tamper contacts should be linked out. If using a normally open button both the alarm and tamper links should be fitted and the normally open switch contacts wired across the links. Figure 2.5 Exit Terminate Wiring shows both configurations for an Exit Terminate button on zone 4. Normally - closed 24 Alarm 24 Alarm Normally - open Tamper Tamper Figure 2.5 Exit Terminate Wiring 8

15 External Bell Connections Connections for Self Actuating Bells (SAB) and Bell/Siren modules should be made with reference to Tables 2.2 and 2.3. These connections are illustrated in Figure 2.6 and Figure 2.7. Control Panel SAB Control Panel Bell / Strobe 12V + Positive supply / hold off 12V + Bell & Strobe positiv e BELL - Bell negative trigge r BELL - Bell negativ e Zone 9 (Tamp -) Negative Supply / hold off Zone 9 (Tamp -) Tamper switch commo n Zone 9 (Tamp Ret) Negative tamper return Zone 9 (Tamp Ret) Tamper switch N/ C STB - Strobe negative trigge r STB - Strobe negativ e Table 2.2 Connections for SABs. Table 2.3 Connections for Bell/Strobe. Zone 9 0V Tamper Return Figure 2.6 SAB SW- STB- 12V+ BELL SW- STB- 12V+ BELL- 0V Tamper return Tamper in Supply - Bell neg. trigger Supply + Strobe neg. trigger SAB Zone 9 Tamper Return - + Strobe Bell + - c Figure 2.7 Bell / Strobe n/o n/c 9

16 Summary of Main PCB Connections Battery / Ground Terminals GND Equipment Ground Terminal - connection must be intact at all times. BATT- Battery Negative - Connect to the -ve (black) terminal of the battery. BATT+ Battery Positive - Connect to the +ve (red) terminal of the battery. Output Triggers (default allocation) 1. Fire trigger 2. Panic trigger 3. Alarm (Intruder) trigger 4. Tamper trigger - responds to tamper alarms when the system is unset. When full set, a tamper alarm activates the Alarm output trigger. 5. Fault trigger - responds to low battery, mains fail, memory checksum failure and watchdog reset. 6. Programme trigger - activates when programming mode is entered. Power / Keypad Terminals AC These two terminals connect to the 13 V a.c. output of the mains transformer. They are not for direct connection to the mains supply. Data Out Connects to the Data Out (yellow) terminal of the Area 1 keypads and the Data Out connections on expansion modules or relay output modules, if fitted. Data In Connect to the Data In (green) terminal of the Area 1 keypads and the Data In connections on any expansion module or relay output module, if fitted. 12 AUX Auxiliary 12 V supply - two pairs of terminals are available for connection of remote keypads and auxiliary fused devices. Note: Area 2 keypads should be connected to the terminal strip marked Area 2 Keypads in Figure 2.8 PCB Connections. A four wire loom is provided for this purpose. The same wiring convention as Area 1 should be followed. Bell / Zone / SW- terminals 1. Switched Negative Supply - This output can be programmed as: (a) Negative supply for smoke detectors or other latching devices which require the interruption of the supply to reset. The output is normally 0 V switching to +12 V for 6 seconds on the second entry of Code + Off after an alarm condition. The output can also be activated at any point in the unset state by pressing the Ö and 1 keys together. (b) Printer data output for a serial printer. (c) Sounder output. 2. Strobe negative - for connection with external strobe negative. 3. Positive bell / strobe supply - common positive, limited by fuse to 1 Amp maximum (labelled F3 in Figure 2.8 PCB Connections). 10

17 4. External bell negative - for connection with switched negative trigger on external bell or SAB switched negative trigger Alarm zones wired as standard double poll zones. ZONE 9 Used for external bell tamper and the on-board cabinet tamper switch. Telephone line - for connection to a NTE5 masterplan line box. 13V AC (Transformer) -VE RTN GND BATT- BATT+ F1 F2 F3 ZONE 9 Bell Tamper ÖNote: If Speaker Module is not fitted,the pins can be used for an internal sounder. -VE (EXIT/ENTRY) -VE (ALARM) +VE (12V SUPPLY) 1 (FIRE) 2 (PANIC) 3 (BURG) 4 (TAMP) 5 (FAULT) 6 (PROG) { { AC AC DATA OUT DATA IN AUX 12V AUX 12V + + OUTPUT TRIGGERS YELLOW GREEN RED BLACK PLUG-IN SPEAKER MODULE DATA OUT DATA IN +12V -12V AREA 2 KEYPADS ADEMCO AC READY ARMED READY OFF AWAY STAY MAX TEST BYPASS INSTANT CODE CHIME Ö 0 # READY PANIC Switch -ve +12V T A ZONE 8 T A ZONE 7 T A ZONE 6 T A ZONE 5 T A ZONE 4 T A ZONE 3 T A ZONE 2 T A ZONE 1 Strobe -ve Bell -ve Figure 2.8 PCB Connections A B BC Telephone line - - AREA 1 KEYPADS 11

18 Telephone Line Installation Before connecting the telephone line, ensure that the system has been correctly installed as detailed herein and that the cable routing has been carried out as advised. Remove the connection to the AC supply by switching off at the external fuse spur or the circuit isolator. Remove the control cabinet cover, as outlined in Fixing the Cabinet, and ensure that the mains indicator on the main PCB is off. Do not attempt to continue if the mains supply is still present within the control. Disconnect the battery leads and remove the battery from the cabinet. Wiring A connection is provided on the Vista 20 for an ex-directory standard PSTN telephone line. This connection must be made to an NTE5 master socket (line box). It is strongly recommended that no telephones or related equipment should be connected to the same telephone line. The connection to the telephone line terminals must only be made by an approved installer. The wiring must be mechanically protected external to the cabinet and must enter via the telephone entry point shown in Figure 2.1 Enclosure Layout. It must not enter the cabinet by any other point. The unit is not suitable for connection to a pay-phone or shared service line and it is not suited for use with PABX or other types of external exchange. It is intended to interface directly with PSTN lines with loop disconnect (pulse dial) or multi-frequency (DTMF) signals. The unit has been approved for the use of the following facilities: modem; loop disconnect signalling; multi-frequency signalling; auto calling; auto answering. Any other usage will invalidate the approval of the apparatus and it will cease to conform with the standards against which the approval was granted. The telephone cable must conform to the requirements of BT specification CW1308. This cable uses a single strand conductor of 0.5mm CSA and the wires are configured in twisted pairs. A suitable cable from RS components is code (2 pair cable). Alarm or any other type of cable must not be used. Communications must only be made to an NTE5 master socket (line box) user port or an extension correctly connected to the master socket. Where terminals use insulated displacement techniques, a special terminal tool must be used. Instructions and wiring call code given in OFTEL wiring code Part 1 must be followed (see Figure 2.9 Telephone Line Connections) i.e. Terminal A - White wire with blue rings - NTE5 terminal 5. Terminal B - Blue wire with white rings - NTE5 terminal 2. Terminal BC - Orange wire with white rings - NTE5 terminal 3. REN The Ringer Equivalence Number (REN) is a guide to the maximum number of items of apparatus which may be connected simultaneously to the telephone line. The total REN is obtained by adding up the REN values of each item of equipment connected to the exclusive line. Any BT approved instrument is assumed to have a REN of 1.0 unless it is otherwise marked. 12

19 The REN of the Vista 20 is 0.5. If the panel is connected to a telephone line with additional telephone apparatus connected then the total REN of the additional apparatus must not exceed 2.5. The Vista 20 is intended to be connected to an exclusive line and it is strongly recommended that no other apparatus should is connected. Warning The approval of this equipment for communication to the PSTN is invalidated if the apparatus is subject to any modification in any material way not authorised by BABT or if it is used with or connected to any of the following: 1. Internal software that has not been formerly accepted by BABT. 2. External control software or external control apparatus which causes the operation of this equipment or associated call set up equipment to contravene the requirements of the BABT standards. (BABT/SITS/82/005S/D). Completion of Installation Replace the control cabinet cover and tighten the two fixing screws. Restore the mains supply to the control. Programme the communication parameters before attempting communication. Approval Your attention is drawn to the approval labels which are fixed to the outside and inside of the control cabinet. This approval number must be quoted when applying to connect the product to the PSTN, when ordering a telephone line or an extension to an existing line or in any communication with the telephone supply authorities. These and other warning labels must not be removed from the product. Figure 2.9 Telephone Line Connections 13

20 14

21 SECTION 3: OPTIONAL MODULES Expander Module The Vista 20 can be expanded by the addition of either one or two expander modules. Each module contains an additional 8 zones and 4 outputs, giving a possible maximum of 24 zones and 14 outputs for the system. The connects to the Vista 20 keypad bus and any break in the bus wiring can be detected and reported by the Vista 20. Similarly, the can detect and report removal of it s cover by use of the built in tamper switch, SW SW1 CASE TAMP Jumper Links LED 1 LED 2 (Red) (Green) OUTPUTS ON SW2 IC2 - + LOOP DOUT +12 0V DIN CONSOLE ALARM TAMP ALARM TAMP ALARM TAMP ALARM TAMP ALARM TAMP ALARM TAMP ALARM TAMP ALARM TAMP ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 Figure Expander Module Addressing The 8-way DIP switch (SW2) is used to set up the keypad bus address and various other functions for the module. The address is set up using switches 1 4 and must be a unique number in the range 0 to 3. This must correspond to the address assignment in field 89 in programming. Table 3.1 Switches 1 4 shows the DIP switch settings for each of the 4 addresses available on the Vista 20. Address DIP switch setting ON ON ON ON Sw. No. Function 5 Zone Mode 6 Protocol 7 Zone Response 8 Status LEDs Table 3.1 Switches 1 4 (address) Table 3.2 Switches 5 8 ON Double Poll Keypad Bus Fast On OFF Balanced EOL Polling Loop Normal Off 15

22 DIP Switches 5-8 Table 3.2 Switches 5 8 lists the module functions controlled by switches 5 to 8. These functions are described below. Zone Mode (Switch 5) Switch 5 changes the zone mode between double poll and balanced end-of-line (EOL). If set to double-poll the zones operate as normally-closed, alarm and tamper loops. If set to balanced EOL, series and end-of line resistors must be used. Refer to Figure 3.2 Balanced EOL Configuration. Protocol (Switch 6) Switch 6 should always be set to ON to enable connection with the Vista 20 keypad bus. Connections should be made to the terminals marked CONSOLE on the The LOOP terminals are not used on the (Another version of the expander (4208-3) will be able to work with the Vista 4140 and 4170 making use of the LOOP connections.) Zone Response (Switch 7) Switch 7 changes the zone response time from Normal to Fast Response. Status LEDs (Switch 8) Switch 8 determines whether the status LEDs (LED 1 and LED2) operate or not. The function of the status LEDs is described in Table 3.4 Status LEDs. Note: When the is configured onto the Vista 20, any DIP switch changes will not take effect until the system power is removed then reconnected. Connections The following procedure should be followed when connecting the expander to the Vista 20: 1. Remove power (mains and battery) from the Vista Referring to Table Connections, connect the four terminals on the CONSOLE terminal strip to the Vista 20 keypad bus using the recommended wiring colours. Either keypad bus 1 or 2 can be used regardless of the area that the zones are assigned to. Keypads, and 4204 modules (see 4204 Relay Module) can be connected in daisy chain or star Vista 20 0V Aux 12V- 12V Aux 12V+ Colour Blac k Red Din Dout Data In Data Out Green Yello w Table Connections 16

23 3. Ensure that the two PCB jumper links shown in Figure Expander Module are fitted. These should always be fitted on the expander. 4. If a lid tamper is required, no connection should be made to the CASE TAMP terminals. Any lid tamper condition will then be reported along the keypad bus. If the CASE TAMP terminals are linked out, the lid tamper is disabled. Zone Wiring DIP switch 5 selects the wiring configuration for the alarm loop of all eight zones. This can either be closed circuit convention or balanced end of line (EOL) configuration. For the balanced EOL configuration the tamper loop must always be closed circuit. This configuration is shown in Figure 3.2 Balanced EOL Configuration. Note: A maximum of 10 contacts can be fitted on each loop for balanced EOL. ALARM TAMP NC tamper loop 1kΩ 1kΩ 1kΩ Outputs The has four programmable output triggers which operate as positive removed (normally 12 V switching to 0 V when active). The outputs are open-collector and can provide a maximum current of 100 ma. A common +12 V connection is available on the same terminal block for use with the outputs. See Figure Expander Module for the location of the outputs on the PCB. Note: Although it is possible to add two expanders and two 4204 relay modules to the system, no more than eight outputs can be used. These can be eight triggers via modules, eight relays via 4204 modules or four triggers and four relays from both module types. Status LEDs The status of the module is displayed on LED1 (red) and LED2 (green) if switch 8 is set to ON. Table 3.4 Status LEDs details the meaning of each state. L ED1 (Red) LED2 (Green) OFF ON FLASHING OFF ON Figure 3.2 Balanced EOL Configuration OFF OFF OFF FLASHIN G Meaning No Power / DIP switch 8 not set No data detected Data detected for keypads only Data detected 4204 for other or ON Data detected for this Table 3.4 Status LEDs 17

24 4204 Relay Module The 4204 relay module adds one to four dry, Single Pole Double Throw (SPDT) relay outputs to the Vista 20. A maximum of two modules can be connected to the Vista 20 keypad bus. The relay outputs can be used as an alternative to using the outputs. The 4204 has a built in tamper switch which allows it to detect the removal of it s cover and report this to the control panel. Communication to the 4204 is supervised so that it cannot be removed from the data bus without detection by the control ON DIP SWITCH COVER TAMPER (REED) SWITCH EITHER OR BOTH CAN BE USED TB RELAY 4 TYPICAL (SHOWN OFF) 4 PIN CONSOLE PLUG DATA IN 0V +12V DATA OUT RELAY 3 RELAY RELAY C NC NO C NC NO C NC NO C NC NO YEL BLK GRN RED DATA OUT 0V DATA IN +12V TB2 Figure Relay Module DIP Switch Settings The address for the 4204 should be set using positions 2-5 of the 5 way DIP switch. The address must be a unique number in the range 0 to 4. Refer to Table 3.5 for settings. DIP switch 1 enables/disables the lid tamper. If set to OFF the tamper is enabled. Address 0 ON DIP switch setting ON ON ON 1 - ON ON ON 2 ON - ON ON ON ON Table DIP Switch Setting 18

25 Panel Connections Connections to the Vista 20 can be made via the four position terminal block TB1, the four pin plug or by using both connections. Figure Relay Module shows the location of these connections. The convention shown in Table 3.6 Panel Wiring should be followed (TB1 or 4 pin plug) Vista 20 Colour 0V Aux 12V- 12V Aux 12V+ Blac k Red Din Dout Data In Data Out Green Yello w Table 3.6 Panel Wiring Relay Connections Connections to the four relays are made via the 12 position terminal block TB2. These are shown in Figure Relay Module. 19

26 4110SM Speaker Module The 4110SM speaker module plugs directly onto the PLJ connector on the Vista 20 PCB, providing an output for a 16 Ω loudspeaker. Once connected, the loudspeaker will respond to Entry/Exit and Alarm conditions. If more than one loudspeaker is required the connections should be arranged such that the resistance across the terminals P1 and P2 is 16 Ω, e.g. two 8 Ω loudspeakers in series. When connecting the speaker module, the adhesive pad should be used to allow bonding to the Vista 20 PCB. Once connected the tone of the loudspeaker can be varied by adjusting the potentiometer, VR1. See Figure SM Speaker Module for details. connection to Vista 20 P5 P4 P3 adhesive pad potentiometer (tone control) VR1 P2 P1 loudspeaker connection Figure SM Speaker Module 20

27 SECTION 4: PROGRAMMING THE VISTA 20 General When access has been made to program mode, the system parameters can be changed from the factory default settings. The default values for each of the parameters are shown in brackets above each programming field. If no changes are made to these defaults the system will operate as an audible only alarm. Entering / Exiting Program Mode To enter engineer mode: Enter engineer code If the engineer code has been lost press the Ö + # keys together within 30 seconds of powering up the system. (No programming will be lost other than date and time). To exit engineer mode: Enter Ö99. The default engineer code is It is strongly recommended that this code is changed by the engineer. Note: Programming mode can only be entered from an Area 1 keypad. Programming Format In engineer mode, the system programming can be modified using the Ö key or viewed using the # key: To programme a field: Enter Ö + field number + field entry (in engineer mode). e.g. to change the engineer code to 1111 enter Ö00 then 1111, where 00 is the field number for the engineer code. Two beeps indicate entry confirmed. To view contents of a field: Enter # + field number (in engineer mode). Each programming field on the following pages is shown preceded by Ö/#. This indicates that the Ö key should be pressed to change the field or the # key should be pressed to view the contents of the field. The Ö key also acts as an enter key when entering less than the maximum number of digits for a particular field. Defaults To return the programming back to factory defaults: Enter Ö97, wait five seconds then enter Ö97 again. Note: This will clear all previous programming. To default the master code (user 01) : Enter Ö95, wait 5 seconds then enter Ö95 again. The default master code is Software Version To view which version of software the control panel is using, enter #92 in engineer mode. 21

28 Programming Fields Entry/Exit Ö/# 08 Secondary Entry Time (for type 02 zones) Ö/# 09 Primary Entry Time (for type 01 zones) (0 6) (0 6) Area 1 Area 2 (0 3) (0 3) Area 1 Area 2 Multiples of 10 Seconds i.e. 01=10 secs, 02=20 secs etc. Multiples of 10 Seconds i.e. 01=10 secs, 02=20secs etc. Ö/# 10 Exit Delay Ö/#17 Supplementary Entry Delay Ö/# 18 Entry Deviation Permitted Ö/# 29 Easy Set Ö/# 21 Exit Tone on STAY Set (0 3) (0 3) Area 1 Area 2 (0) (0) Area 1 Area 2 (0) (0) Area 1 Area 2 (1) (1) Area 1 Area 2 (0) (0) Area 1 Area 2 Multiples of 10 Seconds i.e. 01=10 secs, 02=20secs etc. 00 = Final Contact Set 0 = NO 1= YES 0 = NO If enabled, an internal alarm 1 = YES occurs if the user strays from the entry-route. 0 = NO 1 = YES - use # instead of code 0 = NO 1 = YES If enabled, the entry time is doubled. After the standard entry time elapses an internal alarm occurs. Ö/# 11 Setting Options (0) (0) Area 1 Area 2 0 = Timed Exit or Final Contact Set 1 = Exit Terminate AWAY Set 2 = Exit Terminate AWAY/ STAY If set to 1 or 2, any zone can then be programmed as Push to Set in field 02. If set to 1, an Away set requires to be terminated by a Push to Set button (the exit delay in field 10 will be ignored). Stay set will not require to be terminated by the button (sets after 30 seconds or when button pressed). If set to 2, both Away and Stay set require to be terminate by the Push to Set button. Output Options Ö/# 12 Bell Delay Ö/# 13 Bell Duration 22 (0) (10) Area 1 0 = Instant Bells 1 = 10 minute bell delay Multiples of 2 Minutes i.e. 01 = 2 mins, 10 = 20 mins Note: After the Bell Duration expires the system will re-arm and lock out the alarm zone. The maximum possible number of re-arms is four.

29 Ö/# 14 SW- (Switched -ve Terminal) (0) 0 = Internal Sounder Internal Sounder or Power 1 = Power Reset Reset If set to 1 the SW- terminal can be used as the negative supply for a latching detector. For this setting, the 4110SM loudspeaker module must not be fitted. Ö/# 16 Strobe to Confirm Away Set (0) 0 = NO 1 = YES (strobe operates for three seconds on setting) Ö/# 19 External Bells for Fire (2 0) 00 = No bells for Fire Alarm = Duration in Minutes Ö/# 45 Panel Output Trigger Polarity (0) 0 = Normally 12 V, Active 0 V 1 = Normally 0 V, Active 12 V Ö/# 48 Display Armed Status for Away Set (0) 0 = Blank Display 1 = Show Status Ö/# 65 Area Assignments of (3) (3) (3) (3) (3) (3) 1 = Area 1 Panel Triggers: 2 = Area 2 T1 T2 T3 T4 T5 T6 3 = Area 1 or 2 It is strongly recommended that field 65 is reprogrammed so that each trigger is set to one area only (Area 1 or Area 2). Ö/# 86 Panel Trigger: Output Types (see Table 4.1) Ö/# 85 Expander Module: (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) Output Types (see Table 4. 1) T1 T2 T3 T4 T5 T6 T7 T8 Ö/# 87 Expander Module: Output Options (Table 4. 2) (0 1) (0 2) (0 3) (0 8) (1 1) (1 6) T1 T2 T3 T4 T5 T6 (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) Enter area of each output in 1st digit of each box (1 = Area 1, 2 = Area 2). Enter output option in 2nd digit of each box by matching with the output types making reference to Table 4.2. Ö/# 88 Expander Module: Output Timings - Single Pulse Outputs (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) Length of ON pulse = multiples of 2 seconds (i.e. 01 = 2 seconds). EXCEPT 00 gives 1 second. 23

30 Ö/# 89 Expander Module Address (9) (9) (9) (9) (ZONES) (OUTPUTS) 0-3 = Address 9 = Not Used After entering a zone expander address in field Ö89 the zone responses must be programmed for the expander zones before leaving Program Mode. Field *89 programming The information below describes each digit of field 89 and gives a programming example. 1st digit: tells control panel which address has zones 10 to 17 2nd digit: tells control panel which address has zones 18 to 25 3rd digit: tells control which module address ( or 4204) has outputs 1 to 4 4th digit: tells control which module address ( or 4204) has outputs 5 to 8 Example: System consists of two expander modules and one 4204 output module. The first is addressed as 0, second addressed as 1 and the 4204 module addressed as 2. Each module address can be assigned to zones and outputs in field 89 as follows: Vista 20 Control assigns zones to with address 0 assigns zones to with address 1 Address = Outputs 1-4 Ö Zones Address = 1 assigns outputs 5-8 to module with address 2 assigns outputs 1-4 to module with address Zones Address = Outputs NOT USED Outputs 5-8 Example 1: Field 89 Programming 24

31 Code Output Types Output Options 00 N OT USED 01 FIRE 02 PANIC 03 ALARM 04 PART SET 05 SET LATC H FOLLOW LATC H FOLLOW FOLLOW HOUR LATC H 08 TAMPE R LATC H 09 S ET LATCH Positiv e LATCH (special ) 11 FAULT / TROUBL E 12 COMMUNICATOR FAIL 13 AUX 14 ABORT 15 VERIFIE D 16 PROG 17 ZONE TYPE LINE FAULT 20 BELL LATC H FOLLOW LATC H FOLLO W LATC H FOLLOW FOLLOW FOLLOW FOLLOW Code 21 STROBE Output Types 22 INTERNAL SOUNDER 23 TEST MODE 26 READY 27 ARMED CONFIRMATION 28 ENTRY 29 EXIT 30 ENTRY OR EXIT 33 LOW BATTER Y 34 MAINS FAIL 35 WATCHDO G 36 MEMORY FAIL 37 CHIME 39 PERIODIC TEST 40 USER CODE USER CODE USER CODE ASSIGNED AS TRIGGER ONLY Output Options FOLLOW FOLLO W FOLLOW FOLLOW SINGLE PULSE FOLLOW FOLLO W FOLLO W FOLLO W FOLLOW LATC H LATC H SINGLE PULSE SINGLE PULSE SINGLE PULSE SINGLE PULSE SINGLE PULSE The codes shown for each output type can be entered in field 86 (for panel) and field 85 (for expander). The output options shown only affect expander outputs. Table 4.1 Output Event Types 2nd Digit Function 0 Latch 2 Follo w 3 Single Puls e Explanatio n Output drops to 0V once the start event occurs and is not reset (to +12V) until the master/user code + OFF is entered Output follows start event Output gives a single 0V pulse 3) then restores to +12V of a set duration (see Table One of the three output options above should be selected for each expander output. The output options must be matched with the output responses by referring to Table 4.1. The options chosen should be entered into the second digit of the appropriate boxes in field 87. The first digit is the area (1 or 2). Table 4.2 Output Options for field Ö87 25

32 Engineer Ö/# 00 Engineer Code Ö/# 01 Keypad Lockout ( ) (0) 0 = No Lockout 1 = 15 min. lockout (4 wrong codes) Pressing any key within the lockout period will restart the 15 minute lockout period. Ö/# 06 Technistore Version Number ( 0 0 0) Enter version number used by central station ( ) Ö/# 15 Event Log Printout on Exiting Programming (0) 0 = NO 1= YES Ö/# 23 Tamper : Reset Type Ö/# 24 Alarm : Reset Type (0) (0) 0 = Customer 1 = Engineer 0 = Customer 1 = Engineer 2 = Technistore Code Only 3 = Engineer or Technistore User Access Rights 1 = Area 1 4 = Cleaner 7 = Trigger Output 2 = Area 2 5 = Duress Area 1 8 = Master Area 1 3 = Area 1 & 2 6 = Duress Area 2 9 = Master Area 2 Ö/# 26 User 1-8 Access Rights (3) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) Ö/# 27 User 9-15 Access Rights (1) Area 1 - code sets/unsets Area 1 zones (must be entered at Area 1 keypad). (2) Area 2 - code sets/unsets Area 2 zones (must be entered at Area 2 keypad). (3) Area 1 & 2 - code sets/unsets Area 1 and Area 2 zones. Must be entered at Area 1 keypad to set Area 1 and then Area 2 keypad to set Area 2 (except for User 1). (4) Cleaner - when system is set and cleaner code + off entered, zones with the cleaner access option selected (see Zone Options) are unset. The cleaner code + Away must always be entered when the cleaner is leaving the premises, even if the rest of the system is unset. Otherwise, the cleaner zones remain unset at the next setting. (5) Duress Area 1- any entry of the code at an Area 1 keypad activates an output programmed as PA and sends a PA signal to central station. (6) Duress Area 2 - same as (5) for Area 2. (7) Trigger Output Only - code activates any output programmed as Trigger (type 42). (8) Master Area 1 - sets/unsets Area 1 zones and can change Area 1 codes. (9) Master Area 2 - sets/unsets Area 2 zones and can change Area 2 codes. Note: User 1 always acts as the master code. It is also the only code which full sets (Away) both areas from the one keypad. If using Stay set for both areas then user 1 must be entered at both keypads. 26

33 Zone Programming Options Zone Responses 00 Not Used 06 PA Silent 19 Comms Hold-Off Zone 01 Final Exit (Primary Timer) 07 PA Audible 20 Stay Arm 02 Final Exit (Secondary Timer) Hr Auxiliary 21 Away Arm 03 Intruder 09 Fire 22 Disarm 04 Walk Through 17 Telephone Line Monitor 23 Trigger Output Only Hour Tamper 18 Push Button Set Ö/# 02 Zone 1-8 Response Ö/# 03 Zone Response Ö/# 04 Zone Response (0 1) (0 4) (0 3) (0 3) (0 3) (0 3) (0 3) (0 3) (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) Ö/# 05 Zone 99 (Ö + #) Panic (Both Areas) Ö/# 07 Zone 1-8 Response Time (0 0) (0 0) (0) Enter zone response in first box (06 or 07). Always set second box to = Normal (As per BS4737) 1 = Fast Response (vibration sensors only) Ö/# 39 Zone 1-8 Forced Walk Test Ö/# 40 Zone Forced Walk Test (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) 0 = No 1 = Yes Ö/# 41 Zone Forced Walk Test Ö/# 52 Common Area Zone List Once enabled, if a zone has not been activated during the unset period then the user must activate the zone before the system will set. The keypad will indicate the zone(s) to be activated. (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) (0 0) Enter zone numbers for zones which are common to both areas. These zones will only be active when both area 1 and area 2 are set. 27

34 Zone Options Six zone options can be selected for each zone. These are shown in Table 4.4 as options (a) to (f). ( a) ( b) ( c) ( d) ( e) ( f) ( g) (h) Area 0 = Area 1 1 = Area 2 Isolate in Stay Set 0 = No 1 = Yes Ö/# 53 Zone 1 Options Ö/# 54 Zone 2 Options Ö/# 55 Zone 3 Options Ö/# 56 Zone 4 Options Ö/# 57 Zone 5 Options Ö/# 58 Zone 6 Options Ö/# 59 Zone 7 Options Ö/# 60 Zone 8 Options Bypass Inhibit 0 = No 1 = Yes Cleaner Access 0 = No 1 = Yes Soak Test 0 = No 1 = Yes Table 4.4 Zone Options Double Knock 0 = No 1 = Yes Not Used Must be set to 0 Not Used Must be set to 0 Ö/# 69 Zone 10 Options Ö/# 70 Zone 11 Options Ö/# 71 Zone 12 Options Ö/# 72 Zone 13 Options 28

35 Ö/# 73 Zone 14 Options Ö/# 74 Zone 15 Options Ö/# 75 Zone 16 Options Ö/# 76 Zone 17 Options Ö/# 77 Zone 18 Options Ö/# 78 Zone 19 Options Ö/# 79 Zone 20 Options Ö/# 80 Zone 21 Options Ö/# 81 Zone 22 Options Ö/# 82 Zone 23 Options Ö/# 83 Zone 24 Options Ö/# 84 Zone 25 Options 29

36 Communication The Vista 20 has the capability to transmit in one of two formats to a central station digital receiver. These formats are: (1) Ademco high speed (standard UK high speed format). (2) Ademco contact ID (point ID). The Vista 20 does not require a pre-programmed PROM since all communication parameters are programmed from the Vista 20 keypad. High Speed Format In the standard UK high speed format it is usual to assign channels to the alarm types as follows: Channel 01 is normally assigned for fire alarm conditions. Channel 02 is normally assigned for PA (panic) alarm conditions. Channel 03 is normally assigned for intruder alarms (burglary). Channel 04 reports open/close signals. For the Vista 20 additional channels are assigned as follows: Channel 05 reports daytime tampers. Channel 06 reports trouble conditions. Channel 07 reports an abort code. Channel 08 reports verified alarms. Channel 09 reports low battery and test signals The channel reporting may be enabled/disabled for each zone. Each zone is assigned to channel 03 by default and only requires changing if a different report or no reporting of a zone is required. In addition to alarm reports, a restore report may be sent for each channel. The restore will by default be transmitted after the second entry of code + Off after an alarm condition. This can be changed in programming field 50. Contact ID Format When using contact ID format each event is transmitted as a unique event type (event code) instead of sending channel activations. The user or zone number related to the event is also transmitted along with the message. The data is sent as follows: AAAA Q EEE GG ZZZ, where: AAAA = account number. Q = event qualifier, i.e. E = new event, R = restore. EEE = event code. GG = group number (area). ZZZ = zone or user number. It is advised that each zone is assigned a different channel code to allow more than one zone transmission for a given set period. Fifteen channels can be used for contact ID so it is not possible to put all 24 zones on different channels. It is advised that zones 01 to 13 are assigned to channels 03 to 15. If more than 13 zones are used then zones 14 to 24 should be assigned channels 03 to 13. The only exception is for Fire 30

37 and PA zones; fire zones should be assigned to channel 01 and PA zones to channel 02. These channels are activated for every zone activation during a given set period. Note: Restore signals are sent after the zone clears and not on resetting the system. Ö/# 20 Allow arming with telephone line fault Ö/# 22 Telephone Line Monitor Active (0) (0) 0 = No 1 = Yes 0 = No 1 = Yes Ö/# 30 Dialling Method: Pulse / DTMF (1) 0 = Pulse 1 = DTMF Ö/# 31 PABX Access Code (1 5) (1 5) (1 5) (1 5) Note: The Vista 20 cannot be guaranteed to work with PABX exchanges. Before entering number type Ö 31Ö to delete previous number. Enter as 2 digit numbers e.g. 9 = 09. If using less than 8 digits press Ö to finish. Ö/# 33 Primary Central Station Telephone Number Ö/# 34 Secondary Central Station Telephone Number Before entering new numbers type Ö33Ö (primary) or Ö34Ö (secondary) to delete previous number. If number is less than 16 digits press Ö to finish entry. Ö/# 32 Primary Account Numbers Ö/# 90 Secondary Account Numbers (1 5) (1 5) (1 5) (1 5) Area 1 (1 5) (1 5) (1 5) (1 5) Area 1 (1 5) (1 5) (1 5) (1 5) Area 2 (1 5) (1 5) (1 5) (1 5) Area 2 Ö/# 46 Digicom Format (1) 0 = Contact ID 1 = High Speed (8 channel) Ö/# 49 Checksum Verification (0) 0 = No 1 = Yes (only used on ADEMCO receivers) 31

38 Ö/# 50 Send Restore on 1st code (0) 0 = No (second code + off) + off 1 = Yes Ö/# 51 Dual Reporting (0) 0 = No 1 = Yes (all reports to both Primary and Secondary telephone no.s) Ö/# 67 Non-alarm reports (0) (0) (0) (0) (0) (0) (0) (0) (a) Mains Loss (b) (Not Used) (c) Tamper/Trouble (d) Tamper/Trouble Restore (e) Isolate (Bypass) Restore (f) Isolate (Bypass) (g) Restores (Alarm / Low Batt / Mains Fail) (h) (Not Used) Ö/# 68 Non-alarm reports (a) (b) (c) (d) (e) (f) (g) (h) (0) (0) (0) (0) (0) (0) (0) (0) Open Close Low Battery Verified Alarm (High Speed format only) Test Watchdog Reset Alarm Cancel (Abort) Program Mode Access 0 = No 1 = Yes 0 = No 1 = Yes Ö/# 61 Digicom Channel Codes: Zones 1-8 Ö/# 62 Digicom Channel Codes: Zones 9-16 (0 3) (0 3) (0 3) (0 3) (0 3) (0 3) (0 3) (0 3) (0 3) (0 3) (0 3) (0 3) (0 3) (0 3) (0 3) (0 3) Ö/# 63 Digicom Channel Codes: Zones (0 3) (0 3) (0 3) (0 3) (0 3) (0 3) (0 3) (0 3) Ö/# 64 Digicom Channel Codes: Zones 25 & 99 (Keypad PA) (0 3) (0 2) 00 = No Comms 02 = PA 01 = Fire 03 = Intruder Ö/# 66 Enable Comms in Stay set (0) 0 = No 1 = Yes If enabled, the system will communicate Intruder alarms when Stay set. 32

39 Downloading If the system is to be programmed from NEW by the downloading computer, the following procedure should be used: 1. Enter Program Mode by typing the engineer code Enter Ö97 twice to load the system defaults. 3. Enter Ö35 and enter the telephone number of the downloading computer. 4. Enter Ö99 to exit Program Mode. 5. Contact the downloading computer operator to make sure computer is ready for a site initiated download. 6. Enter # + 1 to initiate dialling. 7. Do not pick up any telephone connected to the same line as the Vista 20 until the download is completed. Ö/# 35 Downloader: Tel No. Before entering new number type Ö35Ö to delete previous number. If number is less than 16 digits press Ö to finish entry. Ö 36 Downloader ID (1 5) (1 5) (1 5) (1 5) (1 5) (1 5) (1 5) (1 5) Ö/# 37 Downloader: Command Enables (1) (1) (1) (1) (1) (1) (1) (1) 0 = No 1 = Yes (a) (b) (c) (d) (e) (f) (g) (h) Dialler Shut Down System Shut Down Access When Set Remote Bypass (Isolate) Remote Disarm Remote Arm Upload Program Download Program If enabled, the commands (a) to (f) can be carried out from the download computer. Ö/# 44 Ring Count (1 2) 00 = No Ring Detect (01-14 rings) 15 = Answering Machine Defeat Enter no. of rings (01 to 14) before panel answers incoming call. If set to 15 panel will only pick up line if download PC calls in, hangs up after 2 rings then redials. 33

40 Alpha-Numeric Keypad - Text Programming Zone descriptors are created by entering words from the built-in library. Alternatively an additional 20 custom words can be created and used. Zone Descriptors To enter a zone descriptor the following steps should be taken: 1. Once in Program Mode type Ö93 to enter text programming mode. 2. From the Zone Descriptors, Enter Zone prompt enter the zone number (01 25). The display then shows the zone number and the character A. 3. Each key represents several characters (see Figure 4.1 Character Allocation). Select the first character of the word required by pressing the relevant key until this letter appears on the display. For example if the letter R is required, press the 6 key three times. If custom words have already been created, the 0 key is used to access them. 4. Once the correct character is displayed, press the Ö key to access the word list. 5. Press any number key (0 9) to scroll forwards through the word list until the required word is displayed. 6. Press the Ö key to accept the selection. The display then shows 0A. 7. Select the 1st letter of the next word by pressing the relevant key (see Figure 4.1) or press Ö to save word into memory. 8. Repeat until the required number of words are displayed (maximum of three). Note: The # key acts as an undo key when programming text. 34 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Ö 0 # Figure 4.1 Character Allocation Custom Words To enter a custom word into the library, use the following procedure: 1. In Program Mode, type Ö93 to enter Text Programming Mode. 2. From the Zone Descriptors, Enter Zone prompt, type 00 to enter Custom Word Programming Mode. 3. Enter the custom word number between 00 and Press the number key which represents the first character of the new word (see Figure 4.1) until this character is shown on the display.

ENGINEER S AL.

ENGINEER S AL. VISTA 25 UK ENGINEER S MANUAL AL i ii Contents SECTION 1: WIRING AND SAFETY INFORMATION... 1 General...1 Siting...1 Fixing... 1 Ventilation...1 Cabling...1 Mains Supply Connections...2 Cable Type...3 Fuses...3

More information

EVO192 v3.0 Fire and Burglary What s New

EVO192 v3.0 Fire and Burglary What s New EVO192 v3.0 Fire and Burglary What s New Compatibility: EVO192 v3.0 TM50 v1.31 K641 v2.41 Overview: CP-01 Compliancy Wiring Diagram The following sections/options have been added to the EVO192 panel. They

More information

EC-P Zone Intruder Alarm System

EC-P Zone Intruder Alarm System EC-P10 10-20 Zone Intruder Alarm System Installation Manual Contents 1. System Overview... 4 System Configuration... 4 Control Panel... 5 Remote Keypads... 5 EC-LED Remote Keypad... 5 EC-LCD Remote Keypad...

More information

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. TABLE OF CONTENTS... P.1 2. GENERAL DESCRIPTION... P.2... 3. STANDARD AND OPTIONAL PARTS LIST... P.2... 4. FEATURE

More information

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual WIC-16Z4P WIC-5Z2P Installation & Operation User Manual Page : 1/34 INDEX # Function Page 1 Abort Current Communication and Clear Reporting Queue (*59) 13 2 Abort Current Communications (*59) 10 3 Account

More information

NESS 5000 SERIES DIALLER

NESS 5000 SERIES DIALLER NESS 5000 SERIES DIALLER INSTALLATION MANUAL This manual is designed to provide the installation instructions on the NESS SECURITY PRODUCT'S 5000 SERIES Dialler. For complete details on the warranty or

More information

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION... 2 2. STANDARD AND OPTIONAL PARTS LIST... 2 3. FEATURE DEFINITIONS... 3 4. TERMINAL DRAWING AND SPECIAL

More information

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...

More information

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION...P.2 2. STANDARD AND OPTIONAL PARTS LIST...P.2 3. FEATURE DEFINITIONS...P.3 4. TERMINAL DRAWING AND

More information

Control/Communicator Installation Manual

Control/Communicator Installation Manual DAS NETWORX NX-12 Control/Communicator Installation Manual General Description...2 Ordering Information...2 Option Definitions...3 Programming the LED Code Pads...5 Programming the NX-12...9 Types of Programming

More information

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide Digiplex System V2.14 / V2.2ACC Control Panel Programming Guide Table of Contents Getting Started...2 What Do I Do First?...2 How Do I Program the Control Panel?...2 Single Digit Entry Method...2 Multiple

More information

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panel with Communicator Interface

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panel with Communicator Interface THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL Security Control Panel with Communicator Interface Table of Contents Table of Contents Section Page 1 Programming Summary 4 1.1 Programming Menu 4 1.1.1

More information

TS5160. Installation & User Guide. Compatible Equipment. CPA6 0M - Output Module Loudspeaker DC54/58 - Digital Communicators (Stand Alone Only)

TS5160. Installation & User Guide. Compatible Equipment. CPA6 0M - Output Module Loudspeaker DC54/58 - Digital Communicators (Stand Alone Only) Installation & User Guide Compatible Equipment CPA6 0M - Output Module 9040 - Loudspeaker DC54/58 - Digital Communicators (Stand Alone Only) 496527 Issue A 1 of 16 TS5160 Overview Introduction Specification

More information

SECURIT 700L PLUS ENGINEERING MANUAL

SECURIT 700L PLUS ENGINEERING MANUAL SECURIT 700L PLUS ENGINEERING MANUAL C & K Systems Ltd 13/03/97 C031-096-02 NEW ENHANCED FEATURE SET Securit 700L PLUS Engineering instructions INTRODUCTION The Securit 700L is a microprocessor intruder

More information

CC408. Quick Reference Guide Solution 880

CC408. Quick Reference Guide Solution 880 CC408 EN Quick Reference Guide Solution 880 CC408 Quick Reference Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd ( Bosch

More information

ADE Gen4. Speech Dialler Engineering Information. Description. Features

ADE Gen4. Speech Dialler Engineering Information. Description. Features ADE Gen4 Speech Dialler Engineering Information Description The Informa is a Speech Dialler for use with intruder alarm systems. When the control panel recognises an alarm it triggers the Informa. The

More information

Installation Manual Premier 412/816/832. Issue 10

Installation Manual Premier 412/816/832. Issue 10 Installation Manual Premier // Issue 0 Premier // Installation Manual 5. Operating the System Introduction Before attempting to operate the alarm system ensure you have familiarised yourself with all the

More information

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION...P.2 2. STANDARD AND OPTIONAL PARTS LIST...P.2 3. FEATURE DEFINITIONS...P.3 4. TERMINAL DRAWING AND

More information

2000 Series. Program Entry Guide. Control Panels

2000 Series. Program Entry Guide. Control Panels 2000 Series EN Program Entry Guide Control Panels 2000 Series Program Entry Guide About This Manual EN 2 About This Manual This guide describes the programming parameters available to the 2000 Series Control

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING -961212-0004 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. ( 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2) Connect

More information

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure. Notice The material and instructions covered in this manual have been carefully checked for accuracy and are presumed to be reliable. However, Radionics, Inc. assumes no responsibility for inaccuracies

More information

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96 Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96 XL-2G Gold Product Overview 7 Zones (6 programmable + panic or keyswitch zone) Fast Loop Response

More information

First Alert 1200C Installer Notes M. Leuck

First Alert 1200C Installer Notes M. Leuck First Alert 2C Installer Notes M. Leuck. Programming can done by standard keypads 2. Enter programming with Installer Code + 8 + + 3. Another method of entering programming: Power system down, then back

More information

Contents. Glossary

Contents. Glossary Contents Glossary ------------------------------------------------------------------------------------------------------ 6 1. Introduction to the IDS 1632 -------------------------------------------------------------

More information

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION...2 STANDARD AND OPTIONAL PARTS LIST...2 FEATURE DEFINITIONS...3 TERMINAL DRAWING AND SPECIAL NOTES...4

More information

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E... 5$1*(5( DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS General Description... 2 Standard and Optional Parts List... 2 Feature Definitions... 3 Comments about the 8600E... 4 Terminal

More information

8 plus and16 plus. User s Guide * # ent. esc GALAXY 16+ V2.XX TUE 30 JUN. IU ZST 962 Issue 2. A u B u

8 plus and16 plus. User s Guide * # ent. esc GALAXY 16+ V2.XX TUE 30 JUN. IU ZST 962 Issue 2. A u B u 8 plus and16 plus User s Guide GALAXY 16+ V2.XX 06.22 TUE 30 JUN 1 2 3 4 5 6 7 8 9 0 * # A u B u ent esc IU1-0018 ZST 962 Issue 2 Contents INTRODUCTION... 1 Glossary of Terms... 3 KEYPAD INFORMATION...

More information

GARDTEC 580. Installation Instructions

GARDTEC 580. Installation Instructions GARDTEC 5 0 0 S E R I E S GARDTEC 580 Installation Instructions Contents Introduction 1 Planning the Control Panel Location 2 Installation 2 Cable Entries 3 Mains Supply Connection 4 Terminal Block Connections

More information

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160 All-In-One Wireless Security System V3.2 Programming Guide Model # MG6130 / MG6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com

More information

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation The most user friendly Contents Section 1 Overview of System 1.1 Kit Contents 1.2 Tools Required 1.3 System Features Security Alarm System L S 4 0 0 Section 2 Planning your Installation 2.1 Location of

More information

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX PROGRAMMING GUIDE SPECTRA CONTROL PANELS V1.2 1725, 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX TABLE OF CONTENTS HOW DO I PROGRAM THE SYSTEM?... 4 Single Digit Data Entry Method (Hexadecimal

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING 48ESEP-01 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)

More information

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL IMPORTANT: Please note the Sterling 10 LCD keypad is not compatible for use with the Sterling 10 ICON keypad. RINS1413-1 Pyronix

More information

Watchguard WGAP864 User Manual

Watchguard WGAP864 User Manual Watchguard WGAP864 User Manual v1.0 Issued September 2016 1 2 Table of Contents Glossary... 5 1. Introduction to your Watchguard WGAP864... 6 2. Before Operating your Alarm System... 6 3. Understanding

More information

Version 1.03 January-2002 USER S MANUAL

Version 1.03 January-2002 USER S MANUAL Version 1.03 January-2002 1 USER S MANUAL 2 Version 1.03 January-2002 System Details CUSTOMER:...... PHONE:... FAX:... INSTALLED BY:...... PHONE:... FAX:... MAINTENANCE & SERVICE:...... PHONE:... FAX:...

More information

TABLE OF CONTENTS TABLE OF CONTENTS 1

TABLE OF CONTENTS TABLE OF CONTENTS 1 TABLE OF CONTENTS TABLE OF CONTENTS 1 FEATURES 2 Keypad Programmable... 2 EEPROM Memory... 2 Static/Lightning Protection... 2 Supervision... 2 Operation... 2 SPECIFICATIONS 2 PC1550 Control Panel... 2

More information

System Introduction. 1.1 Specifications

System Introduction. 1.1 Specifications System Introduction S E C T I O N 1 1.1 Specifications Downloading Software Support PC585 uses DLS-1 v6.5 and up. Flexible Zone Configuration Four fully programmable zones; system expandable to eight zones

More information

CC488. Quick Reference Guide Solution Ultima 880

CC488. Quick Reference Guide Solution Ultima 880 CC488 EN Quick Reference Guide Solution Ultima 880 CC488 Quick Reference Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty

More information

AXI LED USER MANUAL (REV. 1.0)

AXI LED USER MANUAL (REV. 1.0) Security & Home Automation System AXI LED USER MANUAL (REV. 1.0) CONTENTS PREFACE FEATURES LED KEYPAD OUTLOOK 1.0 LIGHT INDICATION 1 2 4 6 CHAPTER 1: ALARM SYSTEM CONTROL 1.0 USING LED KEYPAD 1.0.1 ARMING

More information

Quick Programmer s Manual

Quick Programmer s Manual Version 2.604 (31/03/05) p1 Quick Programmer s Manual 2005. Inner Range Pty. Ltd. Part Number: 630048V2 p2 Version 2.604 (31/03/05) TABLE OF CONTENTS. 1. PROGRAMMING FLOWCHART. The following flowchart

More information

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM 2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM OPERATING INSTRUCTIONS MODELS: 2300 2500 2700 This information is relevant to systems fitted with Issue 4.1 (or later) Master Keypad Software, also to Networked

More information

Engineer Reference. EN :2006+A1:2009 EN :2009 EN :2008 EN :2005+A1:2008 Security Grade 2 Environmental Class II

Engineer Reference. EN :2006+A1:2009 EN :2009 EN :2008 EN :2005+A1:2008 Security Grade 2 Environmental Class II EN50131-1:2006+A1:2009 EN50131-3:2009 EN50131-6:2008 EN50131-5-3:2005+A1:2008 Security Grade 2 Environmental Class II Engineer Reference INTERNAL SIREN WARNING The Enforcer 32-WE control panel contains

More information

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147) -961112-0003 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3

More information

Security System. User Guide for the LED Command Center

Security System. User Guide for the LED Command Center Security System User Guide for the LED Command Center National Security Systems Inc (800)457-1999 MY SECURITY COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY

More information

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0 User s Guide SUB-MA7240O-0001.OG.Solution40-111.doc Created: 6/05/03 Last Updated: 23/09/03 MA7240AO-0001 Version 1.0 2 Table Of Contents User List...6 Quick Reference..7 Features...7 Keypad User's Guide...8

More information

TS700. Intruder Alarm Control Panel OPEN ENT 0 ESC

TS700. Intruder Alarm Control Panel OPEN ENT 0 ESC TS700 Intruder Alarm Control Panel OPEN _ ~ A 1 2 3 B 4 5 6 C 7 8 9 D ENT 0 ESC Setting the System Ent er your pa sscode XXXX then leave the protected area. Unsetting the System Go directly to the keypad

More information

ITI Caretaker Basic Commands

ITI Caretaker Basic Commands ITI Caretaker Basic Commands System can be accessed by telephone or wireless keypad Zones - Up to 30 Wireless or 24 Hardwired Battery - 12 volt 1.9 amp rechargeable Lead-Acid inside main panel, only found

More information

INSTALLATION MANUAL PC56O. Version 1.OA

INSTALLATION MANUAL PC56O. Version 1.OA INSTALLATION MANUAL PC56O Version 1.OA TABLE OF CONTENTS INTRODUCTION 3 Features... 3 Specifications... 3 INSTALLATION 4 Mounting the Control Panel... 4 Mounting the Keypad... 4 Wiring... 5 Burglary Zone

More information

(31/03/05) Version p1. INNER RANGE IQ. Programmer s Manual. Programmer s Manual Inner Range Pty. Ltd. Part Number:

(31/03/05) Version p1. INNER RANGE IQ. Programmer s Manual. Programmer s Manual Inner Range Pty. Ltd. Part Number: (31/03/05) Version 2.604 p1 Programmer s Manual 2005. Inner Range Pty. Ltd. Part Number: 630047 p2 Version 2.604 (31/03/05) TABLE OF CONTENTS. Programming Methods... 3 1. Introduction 1.1 System Overview...

More information

CPA6. Installation & User Guide. Intelligent Security & Fire Ltd. Compatible Equipment

CPA6. Installation & User Guide. Intelligent Security & Fire Ltd. Compatible Equipment Installation & User Guide Compatible Equipment CPA6 OM - Output Module 9040 - Loudspeaker DC54/58 - Digital Communicators (Stand Alone Only) 496524 Issue A 1 of 16 CPA6 Overview Introduction Facilities

More information

Power Wave Zone Alarm Panel V8.5. Installation Manual

Power Wave Zone Alarm Panel V8.5. Installation Manual Power Wave - 8 8 Zone Alarm Panel V8.5 Installation Manual 7 December 2001 Crow (Aust) Electronic Engineering Pty Ltd Corporate Head Office: 429 Nepean Hwy, Brighton East, Vic., 3187 Australia Phone: +61

More information

LS800S Intruder Alarm System. Engineering Manual

LS800S Intruder Alarm System. Engineering Manual LS800S Intruder Alarm System Engineering Manual Table of Contents Section 1 Overview of System 1.1 Kit Contents 1.2 Tools Required 1.3 System Features Section 2 Planning your installation 2.1 Location

More information

Content. 1. Introduction to the IDS Features Installation and Wiring End-of-Line Resistors/Tamper per Zone...

Content. 1. Introduction to the IDS Features Installation and Wiring End-of-Line Resistors/Tamper per Zone... 1 2 Content 1. Introduction to the IDS 805... 7 1.1 Features...7 2. Installation and Wiring...8 3. End-of-Line Resistors/Tamper per Zone...9 4. Connecting the Telephone Communicator...10 5. Programmable

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING -961212-0004 SOFTWARE VERSI 3.10 CTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)

More information

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom CC880/LP880, SC8016 EN Operators Guide Solution-16, Solution-16 Safecom CC880/LP880, SC8016 Operators Guide EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch

More information

AP10LED 10 Zone onboard LED Alarm Panel. Engineering Manual

AP10LED 10 Zone onboard LED Alarm Panel. Engineering Manual AP10LED 10 Zone onboard LED Alarm Panel SAFETY Engineering Manual Before proceeding with the installation, please note the following safety warnings: DO NOT connect the mains supply directly to the product,

More information

CONTENTS. 1 INTRODUCTION 2 Planning the installation 2 Nexus 8 installation example 3

CONTENTS. 1  INTRODUCTION 2 Planning the installation 2 Nexus 8 installation example 3 CONTENTS INTRODUCTION 2 Planning the installation 2 Nexus 8 installation example 3 INSTALLATION 4 Nexus 8 system diagram 4 Nexus 8 internal layout 5 Removing the gear tray 5 Mounting the panel / Cable

More information

Independent Zone Control (I.Z.C.)

Independent Zone Control (I.Z.C.) Operation and Installation Guide Independent Zone Control (I.Z.C.) DELAYED INSTANT ARMED 1 2 3 4 7 5 6 8 9 * * fi Radionics R D279A Operation & Installation Guide 46456B Page 2 Copyright 2000 Radionics

More information

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2 INSTALLATION 3 Mounting the Panel... 3 Mounting the Keypad... 3 Auxiliary Power Connection... 3 PGM Terminal Connections... 3 Bell/Siren Connection... 3 Keypad

More information

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: -961112-0002 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3

More information

USER GUIDE HARDWIRED CONTROL PANELS

USER GUIDE HARDWIRED CONTROL PANELS USER GUIDE HARDWIRED CONTROL PANELS Scantronic Contents 1. Introduction... 3 The Alarm System... 3 The Keypads... 3 The 725r Remote Setting Device... 6 About This Guide... 6 2. Everyday Operation... 7

More information

Property of Monitronics Inc

Property of Monitronics Inc Enter Program Program Location 1. Hold 8 key for 3 seconds, keypad will beep 2. Enter 4 5 6 7 8 9, display should show dash on display 1. Press [B/A] key display will show 3 dashs 2. Enter 3-digit location

More information

Solution 862 Installation Manual ISSUE 1.30

Solution 862 Installation Manual ISSUE 1.30 Solution 862 Installation Manual ISSUE 1.30 MA406I This page has been included for you to cut out and insert into the spine of the folder Solution 862 Installation Manual ISSUE 1.30 (61-2) 9672 1233 Solution

More information

M800, M800iD Plus, M1000 and M3000. User's Guide

M800, M800iD Plus, M1000 and M3000. User's Guide M800, M800iD Plus, M1000 and M3000 User's Guide Cooper Security Limited 2005 Every effort has been made to ensure that the contents of this book are correct. However, neither the authors nor Cooper Security

More information

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE D (OPERATION) INITIATE A DYNAMIC BATTERY TEST The system tests the back-up battery once every 24 hours. The owner can initiate a dynamic battery test at any time with the following codes while the system

More information

HARDWIRED CONTROL PANELS

HARDWIRED CONTROL PANELS USER'S GUIDE HARDWIRED CONTROL PANELS Cooper Security Limited 2007 Every effort has been made to ensure that the contents of this book are correct. However, neither the authors nor Cooper Security Limited

More information

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice. BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice. via Florida Z.I. Valtesino - 63013 GROTTAMMARE (AP) - ITALY Installation and Quick guide: DUAL

More information

Protégé EliteSuite Eclipse LED Keypad Installation Manual ELT-KLES

Protégé EliteSuite Eclipse LED Keypad Installation Manual ELT-KLES Protégé EliteSuite Eclipse LED Keypad Installation Manual ELT-KLES The specifications and descriptions of products and services contained in this manual were correct at the time of printing. Integrated

More information

INSTALLATION MANUAL & PROGRAM RECORD SHEET

INSTALLATION MANUAL & PROGRAM RECORD SHEET INSTALLATION MANUAL & PROGRAM RECORD SHEET TABLE OF DESCRIPTION CONTENTS PAGE WIRING MANUAL 2-6 MENU CHART 7 INSTALLER FUNCTIONS 8 MENU 1 SYSTEM TIMES 9 MENU 2 ZONE CONFIGURATION 10-14 MENU 3 SYSTEM OPTIONS

More information

INSTALLATION AND PROGRAMMING MANUAL

INSTALLATION AND PROGRAMMING MANUAL INSTALLATION AND PROGRAMMING MANUAL Contents Section 0. Section 1. Section 2. Section 3. Section 4. Section 5. Section 6. Section 7. Section 8. Section 9. Section 10. Section 11. Section 12. Section 13.

More information

2200 and 2200L ALARM CONTROL SYSTEMS

2200 and 2200L ALARM CONTROL SYSTEMS 2200 and 2200L ALARM CONTROL SYSTEMS OPERATING INSTRUCTIONS MODELS: 2200 (fitted software 3.4 or later) 2200L (fitted software 3.9L or later) Castle Care-Tech Ltd. 2200/2200L Alarm System Operating Manual

More information

Security System. User s Guide for the Text Command Center

Security System. User s Guide for the Text Command Center User s Guide for the Text Command Center MY ALARM COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY CONTROL PANEL IS CONNECTED TO THE PHONE JACK LOCATED:

More information

Galaxy 2 Series. Installation Manual. Honeywell Security

Galaxy 2 Series. Installation Manual. Honeywell Security Galaxy 2 Series Installation Manual Honeywell Security Galaxy 2 Series Installation Manual Table of Contents Contents SECTION 1: INTRODUCTION... 1 Optional Peripherals... 1 Features... 2 RF... 2 Groups...

More information

6HFXULW\6\VWHP,QVWDOODWLRQDQG6HW8S*XLGH N7227AUV2 12/99

6HFXULW\6\VWHP,QVWDOODWLRQDQG6HW8S*XLGH N7227AUV2 12/99 9,67$6(D 6HFXULW\6\VWHP,QVWDOODWLRQDQG6HW8S*XLGH * N7227AUV2 12/99 Table of Contents Section 1. GENERAL DESCRIPTION...1-1 About the VISTA-10SEa...1-1 Basic Wired Zones...1-1 Optional Expansion Zones...1-1

More information

First page of this international document resides under separate cover: 20SEaCOV.ps

First page of this international document resides under separate cover: 20SEaCOV.ps First page of this international document resides under separate cover: 20SEaCOV.ps TABLE OF CONTENTS Section 1. GENERAL DESCRIPTION... 6 Section 2. INSTALLING THE CONTROL... 9 Mounting the Cabinet...

More information

Installation & Programming Guide

Installation & Programming Guide Alert Version 8 Zone Control Arrowhead Alarm Products Ltd Installation & Programming Guide Proudly Designed and Manufactured in New Zealand Arrowhead Alarm Products Ltd PHONE: (09) 579 7506 FAX: (09) 579

More information

INSTALLATION MANUAL SECURIT 802 CONTROL PANEL

INSTALLATION MANUAL SECURIT 802 CONTROL PANEL INSTALLATION MANUAL SECURIT 802 CONTROL PANEL S802 CONTENTS Warnings 2 Standards 2 Warranty Statement 2 Product Description 2 Available Parts 2 Intended use 2 Specifications 3 Processor Version 3 Power

More information

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup NetworX Series NX-8 Commercial Fire Panel Installation and Startup 2004 GE Security All rights reserved. Printed in the United States of America. These instructions do not purport to cover all details

More information

System Introduction. 1.1 Specifications S E C T I O N 1

System Introduction. 1.1 Specifications S E C T I O N 1 System Introduction S E C T I O N 1 1.1 Specifications Control Panel Specifications Flexible Zone Configuration: 8 Fully Programmable Zones 37 Access Codes: 32 User, 1 System Master, 2 Partition Master

More information

Solution-16/ Solution-16 Safecom Installation Manual ISSUE 2.10

Solution-16/ Solution-16 Safecom Installation Manual ISSUE 2.10 Solution-16/ Solution-16 Safecom Installation Manual ISSUE 2.10 MA880I Solution-16/ This page has been included for you to cut out and insert into the spine of the folder Solution-16 Safecom Installation

More information

DYGIZONE GJD910 Lighting Controller & Enunciator

DYGIZONE GJD910 Lighting Controller & Enunciator DYGIZONE GJD910 Lighting Controller & Enunciator MASTER WIRING IDENTIFICATION Power up to the DygiZone and you will see: All the LED s (red,yellow,green and blue buttons) will flash All the LCD icons will

More information

Training Manual Multi-Language with Wireless

Training Manual Multi-Language with Wireless Training Manual Multi-Language with Wireless Installer Training Firmware Version 2.3 X16 Stock Code: 860-1-473-X16 X64 Stock Code: 860-1-864-XS 2 Contents IDS X Series Training V2.3 Contents Contents 3

More information

Security System With Scheduling. User Guide. N5943-8V4 7/04 Rev A

Security System With Scheduling. User Guide. N5943-8V4 7/04 Rev A ADEMCO VISTA-120 Security System With Scheduling User Guide N5943-8V4 7/04 Rev A Your Honeywell security system is designed for use with devices manufactured or approved by Honeywell for use with your

More information

16 and 16 plus User s Guide

16 and 16 plus User s Guide 16 and 16 plus User s Guide GALAXY 16+ V2.XX 06.22 TUE 30 JUN 1 2 3 4 5 6 7 8 9 * 0 # A u B u ent esc Contents INTRODUCTION... v QUICK OPERATION GUIDE...vii GLOSSARY OF TERMS... ix KEYPAD INFORMATION...

More information

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions WIC-16Z4P WIC-5Z2P User Instructions Page : 2/14 INDEX # Function Page 1 Add a New User Code 11 2 Arm or Disarm All Areas or Disarm Selected Areas (Partitioned System) 8 3 Arming the System (Away Mode)

More information

USER GUIDE HARDWIRED CONTROL PANELS

USER GUIDE HARDWIRED CONTROL PANELS USER GUIDE HARDWIRED CONTROL PANELS Contents 1. Introduction... 3 The Alarm System... 3 The Keypads... 3 The 725r Telecommand (Remote Setting Device)... 5 About This Guide... 5 2. Everyday Operation...

More information

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand 6 Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd Operating Guide 1 Proudly Designed and Manufactured in New Zealand CONTENTS Page No. INTRODUCTION 3 About your Alarm 3 OPERATING YOUR

More information

PCX 46 App Programming Reference

PCX 46 App Programming Reference 1. Contents Page 1. Contents Page... 2 2. Introduction... 3 2.1 Hybrid Integrated System with Automation Control... 3 2.2 Two-Way Wireless Technology... 3 2.3 User Automation Outputs... 3 2.4 SMS Text

More information

Training Manual with Bi-directional Wireless

Training Manual with Bi-directional Wireless Training Manual with Bi-directional Wireless Installer Training Firmware Version 2.7x X16 Stock Code: 860-1-473-X16 X64 Stock Code: 860-1-864-XS 2 IDS X-Series Training v2.7 Contents Contents 3 X-Series

More information

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ READY ARMED READY 1 OFF 7 INSTANT READY 2 AWAY 8 CODE 6BYPASS 9 CHIME 9,67$% &RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ 8VHU*XLGH ARMED READY 1 OFF 2 AWAY 3 STAY 4 MAX 5 TEST 6 BYPASS

More information

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68) F A 1 7 0 0 c Testing the System Battery Test When AC power is present, the FA1700C runs a brief battery test every 60 seconds to determine if there is a battery connected, and runs an extended battery

More information

Solution-6 Operators Manual Page 1 Preface Congratulations on selecting the Solution-6 security control system for your installation. So that you can obtain the most from your unit, we suggest that you

More information

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1 1.1 PC5015 Specifications System Introduction S E C T I O N 1 Flexible Zone Configuration: 8 Fully Programmable Zones 38 Access Codes: 32 User, 1 System Master, 2 Partition Master, 2 Duress and 1 maintenance

More information

NX-148 LCD CODE PAD TABLE OF CONTENTS

NX-148 LCD CODE PAD TABLE OF CONTENTS NX-148 LCD CODE PAD TABLE OF CONTENTS Glossary Of Terms... 4 Understanding The Lights... 5 Code Pad Functions Arming In The ON Mode... 6 Making The System Ready To Arm... 7 Using Quick Arm... 7 Arming

More information

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide MG6250 2-Partition 64-Zone Wireless Console with GPRS/GSM Version.6 Section Programming Guide Things You Need to Know About this Programming Guide The MG6250 All-in-one Wireless Console can be programmed

More information

Series. NX-4-EUR Control Panel. Installation manual

Series. NX-4-EUR Control Panel. Installation manual g GE Security NetworX TM Series NX-4-EUR Control Panel Installation manual CONTENTS CONTENTS...2 GENERAL INFORMATION...4 ORDERING INFORMATION...4 FEATURE DEFINITIONS...5 PROGRAMMING THE NX-4 KEYPADS...12

More information

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00 INHEP DIGITAL IDS S E C U R I T Y IDS816 User Manual MANUAL NO. 700-283-01C ISSUED APRIL 2005 VERSION 2.00 Contents 1. Introduction to the IDS816... 4 2. Understanding the Keypad Indicators... 4 3. Programmable

More information

ELT-KLED EliteSuite LED Keypad Installation Manual

ELT-KLED EliteSuite LED Keypad Installation Manual ELT-KLED EliteSuite LED Keypad Installation Manual ELT-KLED EliteSuite Installation Manual PUBLICATION INFORMATION First Publication Draft Document Release Only Updated fire zone information Second Publication

More information

INSTALLATION MANUAL DV8OOO. Software Version 1.0

INSTALLATION MANUAL DV8OOO. Software Version 1.0 INSTALLATION MANUAL DV8OOO Software Version 1.0 *DVACS is a registered trade mark of Electro Arts Limited and covers a wide variety of products. Full DVACS compatability applies only when the Sur-Gard

More information

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2 Architectural & Engineering Specifications Control Panel 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality assurance...

More information