HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

Size: px
Start display at page:

Download "HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide"

Transcription

1 HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide March 2006 (First Edition) Part Number

2 Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. March 2006 (First Edition) Part Number Audience assumptions This document is for the person who installs racks and rack products. This procedure is performed only by trained personnel. HP assumes you are qualified in performing installations and trained in recognizing hazards in rack products.

3 Contents HP Power Distribution Unit with Power Monitoring (Models S124 and S132)... 5 HP Power Distribution Unit with Power Monitoring (Models S124 and S132) overview... 5 HP Power Distribution Unit with Power Monitoring (Models S124 and S132) components... 6 Model information... 6 Installation... 8 Installation overview... 8 Important safety information... 8 Kit contents... 9 Required tool... 9 Installing the HP Power Distribution Unit with Power Monitoring (Models S124 and S132) in the standard mount position Installing the HP Power Distribution Unit with Power Monitoring (Models S124 and S132) in an alternative mount position Checking the circuit breakers External ground bonding Front panel display Front panel display overview Front panel display components HP Power Distribution Unit with Power Monitoring (Models S124 and S132) normal operating conditions HP Power Distribution Unit with Power Monitoring (Models S124 and S132) alarm operating conditions Current alarms Voltage alarms Specifications S124 model information S124 input ratings S124 number of outlets S124 output ratings S132 model information S132 input ratings S132 number of outlets S132 output ratings Environmental specifications Regulatory compliance notices Regulatory compliance information Federal Communications Commission notice FCC rating label Class A equipment Class B equipment Declaration of conformity for products marked with the FCC logo, United States only Modifications Cables Canadian notice (Avis Canadien) European Union regulatory notice Disposal of waste equipment by users in private households in the European Union Electrostatic discharge Preventing electrostatic discharge Grounding methods to prevent electrostatic discharge Contents 3

4 Technical support HP contact information Before you contact HP Acronyms and abbreviations Index Contents 4

5 HP Power Distribution Unit with Power Monitoring (Models S124 and S132) In this section HP Power Distribution Unit with Power Monitoring (Models S124 and S132) overview... 5 Model information... 6 HP Power Distribution Unit with Power Monitoring (Models S124 and S132) overview The HP Power Distribution Unit with Power Monitoring (Models S124 and S132) is a PDU optimized for vertical mounting in HP Series racks (36U or larger). This product provides: Vertical mounting in the rear of the rack, maximizing rack space (no additional parts are required for mounting) Power cord retention bands A front panel display that indicates operating parameters Three color-coded load segments HP Power Distribution Unit with Power Monitoring (Models S124 and S132) 5

6 HP Power Distribution Unit with Power Monitoring (Models S124 and S132) components Callout Description 1 C19 outlet 2 C13 outlet 3 Load segment 4 Power cord 5 Front panel display 6 Mounting bracket 7 Circuit breaker 8 Circuit breaker 9 Circuit breaker Model information There are two different plug and power cord configurations, with a single model for each. HP Power Distribution Unit with Power Monitoring (Models S124 and S132) 6

7 Single PDU North America and Japan model S124 Single PDU International model S132 For detailed model information, refer to the "Specifications (on page 23)" section in this document. HP Power Distribution Unit with Power Monitoring (Models S124 and S132) 7

8 Installation In this section Installation overview... 8 Installing the HP Power Distribution Unit with Power Monitoring (Models S124 and S132) in the standard mount position Installing the HP Power Distribution Unit with Power Monitoring (Models S124 and S132) in an alternative mount position Checking the circuit breakers External ground bonding Installation overview The PDU can be mounted in the rack so that the circuit breakers are at the top of the unit or on the bottom of the unit to accommodate multiple configuration options. The PDU can be mounted in the rack the following ways: Standard mount ("Installing the HP Power Distribution Unit with Power Monitoring (Models S124 and S132) in the standard mount position" on page 10) NOTE: This product arrives with the mounting brackets already installed for a standard right side, circuit breakers at the bottom mount. Right side, circuit breakers at the bottom Left side, circuit breakers at the top Alternative mount ("Installing the HP Power Distribution Unit with Power Monitoring (Models S124 and S132) in an alternative mount position" on page 16) Right side, circuit breakers at the top Left side, circuit breakers at the bottom Important safety information Before installing this product, read the Important Safety Information guide provided. WARNING: To reduce the risk of personal injury from electric shock, do not remove the cover. There are no field-serviceable or user-serviceable components inside. WARNING: A risk of personal injury from electric shock and hazardous energy levels exists. The installation of options and routine maintenance and service of this product must be performed by individuals who are knowledgeable about the procedures, precautions, and hazards associated with AC power products. Follow these safety precautions when connecting multiple pieces of information technology equipment to power products. WARNING: To reduce the risk of personal injury from high-leakage current, verify earth connection before connecting the power supply. Installation 8

9 The summation of input power for multiple pieces of information technology equipment through the use of power products can result in high-leakage currents. If the total system leakage current for a system of components exceeds 3.5 ma: The use of a detachable input power cord is prohibited. The input power cord must be securely attached, and it should be connected to the AC mains by hardwiring or through the use of a non-residential, industrial-style plug that maintains positive earth connection. If the total system leakage current through the ground conductor exceeds 5% of the input current per line under normal operating conditions, the system loads should be divided among multiple power connections. Kit contents Required tool The following hardware pieces are included: One of the following: S124 (North American and Japanese model) S132 (International model) Power cord retention bands (40) 5.5 mm x 12 mm self-tapping screws Sample of cord sets (PDU power cords and jumper cables) 10A, 1.67 ft Jumper cord IEC 320 C13-C14 10A, 4.5 ft Jumper cord IEC 320 C13-C14 Extra hardware might be included for your convenience. You will need a Phillips screwdriver. Installation 9

10 Installing the HP Power Distribution Unit with Power Monitoring (Models S124 and S132) in the standard mount position 1. Slide the tabs on the PDU mounting bracket into the rack frame. Installation 10

11 2. Insert one or more screws into the mounting bracket, securing the PDU to the rack frame. Installation 11

12 3. Plug the device power cords into the PDU. Installation 12

13 4. (Optional) Wrap a power cord retention band around each power cord, and insert the end of the power cord retention band into the appropriate slot on the PDU mounting bracket. Firmly pull the power cord retention bands tight, paying special attention not to sever them. 5. Be sure that the circuit breakers are in the off position. Installation 13

14 6. Plug the PDU power cord into the appropriate power outlet. Installation 14

15 7. Power on the PDU circuit breakers. Installation is complete. Installation 15

16 Installing the HP Power Distribution Unit with Power Monitoring (Models S124 and S132) in an alternative mount position 1. Remove the six screws that secure the mounting brackets to the PDU. Installation 16

17 2. Rotate the PDU 180 degrees, so that the power cord is at the top of the rack. Installation 17

18 3. Reattach the mounting brackets to the PDU using the same six screws from step Continue to "Installing the HP Power Distribution Unit with Power Monitoring (Models S124 and S132) in the standard mount position (on page 10)." Checking the circuit breakers If power to a load segment is interrupted, check the circuit breakers and reset them if necessary. If power is still not restored, contact your HP authorized service representative. External ground bonding There is an external ground bonding point located on the front of the PDU. This bonding point can be used to bond other conductive metal components, located in the rack enclosure, to a ground reference point for signaling or other functional purposes. This bonding point can also be used to bond the PDU to a known earthed reference terminal in the building. Per international regulatory requirements, the primary Safety Earth Bond connection is contained in the PDU as an integral part of the branch circuit cabling and plug. Installation 18

19 Front panel display In this section Front panel display overview HP Power Distribution Unit with Power Monitoring (Models S124 and S132) normal operating conditions HP Power Distribution Unit with Power Monitoring (Models S124 and S132) alarm operating conditions Front panel display overview The PDU front panel has a two-digit, LED display that shows the current in each circuit breaker, a scroll button to scroll through values, and six LEDs, which indicate current overloads and voltage out of range conditions. During the power-on process or after a power restart, all of the indicators on the front panel display are illuminated for a minimum of two seconds to verify operation (the bicolor LEDs are switched every second during this verification process). Front panel display components Front panel display 19

20 Callout Description 1 Reset button 2 Local configuration port ( Ο Ο 1) 3 Green load segment LED (L3) 4 Green load segment LED (L2) 5 Green load segment LED (L1) 6 Amber/red alarm load segment LED (L3) 7 Amber/red alarm load segment LED (L2) 8 Amber/red alarm load segment LED (L1) 9 Remote communication port ( Ο Ο 2) 10 Scroll button 11 Seven-segment LED numeric display Front panel display scroll button Pushing the scroll button once switches the front panel display from one load segment to the next. The circuit displays in the following order as the scroll button is pushed: L1, L2, and L3. The flashing LED indicates which load segment is displayed. Inverting the numerical display If you are mounting the PDU in the rack with the circuit breakers at the top, press and hold the scroll button for over three seconds to invert the seven-segment display 180 degrees. HP Power Distribution Unit with Power Monitoring (Models S124 and S132) normal operating conditions The dual seven-segment display shows the current in the load segment selected. For current values above 1 amp, the value is displayed without a decimal point. For example, 1 amp is displayed using only the right-most digit. During normal conditions, all load segment LEDs are illuminated green. The illuminated green LED corresponding to the load segment currently being displayed flashes. If an alarm condition exists, the load LED for that load segment is not illuminated green, but rather amber or red. After 5 minutes of inactivity, if no alarms are present, the front panel display begins to automatically scroll through the load segments. Inactivity is defined as no user inputs for example, not pushing the scroll button, for 5 minutes. When the unit is automatically scrolling through each load segment the current displays for 3 seconds before switching to the next segment. When the scroll button is pushed during the automatic function, the automatic function is terminated until the 5-minute criteria for automatic scrolling is met again. HP Power Distribution Unit with Power Monitoring (Models S124 and S132) alarm operating conditions The following alarm conditions are indicated by flashing alarm LEDs on the front panel display: Current Overload Overload Current greater than 102% of allowed maximum per load segment (red alarm LED) Front panel display 20

21 If an overload condition exists, the corresponding load segment LED with the alarm condition is illuminated red, while the green load segment LED for that particular load segment is not illuminated. Load Warning Current greater than 80%, but less than 102%, of allowed maximum per load segment (amber alarm LED) If a load warning condition exists, the corresponding load segment LED with the alarm condition is illuminated amber, while the green load segment LED for that particular load segment is not illuminated. Voltage Out of Range Overvoltage of 10% to 20% (amber alarm LED), overvoltage of greater than 20% (red alarm LED) Undervoltage of 10% to 20% (amber alarm LED), undervoltage of more than 20% (red alarm LED) When an alarm condition occurs, the front panel display automatically changes to show the circuit with the alarm condition, regardless of the present display setting. The automatic scrolling function is disabled when an alarm condition exists. If an alarm condition displays and you scroll to display another circuit that does not have an alarm condition present, the circuit without an alarm is displayed for 10 seconds and then switches back to the alarmed circuit. If an alarm condition displays and you scroll to another circuit with an alarm condition, the display remains on the last circuit selected with an alarm until the alarm condition clears or you scroll to a different circuit. If multiple circuits have alarm conditions at the same time, the last circuit to activate an alarm is displayed. Current alarms NOTE: The values in the table below are expressed in amps. The front panel display does not show values in tenths. Load segment conditions 80% 102% Greater than 102% of max rated Load warning Overload Alarm LED colors Amber Red Models S S Voltage alarms NOTE: The values in the table below are expressed in VAC. The front panel display does not show voltage values. Alarm LEDs Circuit breaker open Less than -20% of nominal Less than - 10% and greater than - 20% Within +/- 10% of nominal line voltage Greater than 10% and less than 20% Greater than 20% of nominal Off Undervoltage Undervoltage Normal Overvoltage Overvoltage NA -20%, red alarm LED -10%, amber alarm LED green LED +10%, amber alarm LED +20%, red alarm LED Models S S Front panel display 21

22 Front panel display 22

23 Specifications In this section S124 model information S132 model information Environmental specifications S124 model information Item Input Phases 1 Input plugs Typical electrical service Specification Single NEMA L6-30P Single-phase 208 VAC Callout Description 1 Receptacle 2 Plug S124 input ratings Model Voltage (VAC) Current (amps) Current (amps) derated Current (amps) per phase S V 50/60 Hz 1 phase Not applicable Specifications 23

24 S124 number of outlets Model C13 per load segment C19 per load segment C13 per PDU S C19 per PDU S124 output ratings Model Current (amps) C13 outlet rating Current (amps) C19 outlet rating Max current (amps) load per segment Max current (amps) PDU total S ,992 Power (watts) line cord total S132 model information Item Input Phases 1 Input plugs Typical electrical service Specification Single IEC309-32A-3 wire (2 poles + gnd) Single-phase 230 VAC Callout Description 1 Receptacle 2 Plug S132 input ratings Model Voltage (VAC) Current (amps) Current (amps) derated Current (amps) per phase S V 50/60 Hz 1 phase Not applicable Specifications 24

25 S132 number of outlets Model C13 per load segment C19 per load segment C13 per PDU S C19 per PDU S132 output ratings Model Current (amps) C13 outlet rating Current (amps) C19 outlet rating Max current (amps) load per segment Max current (amps) PDU total S ,360 Power (watts) line cord total Environmental specifications Feature Operating temperature Specification 10 C to 50 C (50 F to 122 F); Internal rack temperature Transit temperature -30 C to 60 C (-22 F to 140 F) Storage temperature Operating humidity -20 C to 60 C (-4 F to 140 F) 10 to 90% relative humidity (non-condensing) Operating altitude 0 to 3,048 m (10,000 ft) above sea level Nonoperating altitude 15,000 m (49,212 ft) above sea level Specifications 25

26 Regulatory compliance notices In this section Regulatory compliance information Federal Communications Commission notice Declaration of conformity for products marked with the FCC logo, United States only Modifications Cables Canadian notice (Avis Canadien) European Union regulatory notice Disposal of waste equipment by users in private households in the European Union Regulatory compliance information All regulatory certifications for these products were obtained under the following agency series numbers. Model S124 S132 Series number HSTNR-P005 HSTNR-P006 Federal Communications Commission notice Part 15 of the Federal Communications Commission (FCC) Rules and Regulations has established Radio Frequency (RF) emission limits to provide an interference-free radio frequency spectrum. Many electronic devices, including computers, generate RF energy incidental to their intended function and are, therefore, covered by these rules. These rules place computers and related peripheral devices into two classes, A and B, depending upon their intended installation. Class A devices are those that may reasonably be expected to be installed in a business or commercial environment. Class B devices are those that may reasonably be expected to be installed in a residential environment (for example, personal computers). The FCC requires devices in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user. FCC rating label The FCC rating label on the device shows the classification (A or B) of the equipment. Class B devices have an FCC logo or ID on the label. Class A devices do not have an FCC logo or ID on the label. After you determine the class of the device, refer to the corresponding statement. Class A equipment This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Regulatory compliance notices 26

27 instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at personal expense. Class B equipment This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit that is different from that to which the receiver is connected. Consult the dealer or an experienced radio or television technician for help. Declaration of conformity for products marked with the FCC logo, United States only This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For questions regarding this product, contact us by mail or telephone: Hewlett-Packard Company P. O. Box , Mail Stop Houston, Texas HP-INVENT ( ). (For continuous quality improvement, calls may be recorded or monitored.) For questions regarding this FCC declaration, contact us by mail or telephone: Hewlett-Packard Company P. O. Box , Mail Stop Houston, Texas To identify this product, refer to the part, series, or model number found on the product. Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett-Packard Company may void the user s authority to operate the equipment. Regulatory compliance notices 27

28 Cables Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations. Canadian notice (Avis Canadien) Class A equipment This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Class B equipment This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. European Union regulatory notice This product complies with the following EU Directives: Low Voltage Directive 73/23/EEC EMC Directive 89/336/EEC Compliance with these directives implies conformity to applicable harmonized European standards (European Norms) which are listed on the EU Declaration of Conformity issued by Hewlett-Packard for this product or product family. This compliance is indicated by the following conformity marking placed on the product: This marking is valid for non-telecom products and EU harmonized Telecom products (e.g. Bluetooth). This marking is valid for EU non-harmonized Telecom products. *Notified body number (used only if applicable refer to the product label) Regulatory compliance notices 28

29 Disposal of waste equipment by users in private households in the European Union This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product. Regulatory compliance notices 29

30 Electrostatic discharge In this section Preventing electrostatic discharge Grounding methods to prevent electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device. To prevent electrostatic damage: Avoid hand contact by transporting and storing products in static-safe containers. Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations. Place parts on a grounded surface before removing them from their containers. Avoid touching pins, leads, or circuitry. Always be properly grounded when touching a static-sensitive component or assembly. Grounding methods to prevent electrostatic discharge Several methods are used for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts: Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm ±10 percent resistance in the ground cords. To provide proper ground, wear the strap snug against the skin. Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats. Use conductive field service tools. Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part. For more information on static electricity or assistance with product installation, contact an authorized reseller. Electrostatic discharge 30

31 Technical support In this section HP contact information Before you contact HP HP contact information For the name of the nearest HP authorized reseller: In the United States, refer to the HP US service locator webpage ( In other locations, refer to the HP website ( For HP technical support: In North America: Call HP-INVENT ( ). This service is available 24 hours a day, 7 days a week. For continuous quality improvement, calls may be recorded or monitored. If you have purchased a Care Pack (service upgrade), call For more information about Care Packs, refer to the HP website ( Outside North America, call the nearest HP Technical Support Phone Center. For telephone numbers for worldwide Technical Support Centers, refer to the HP website ( Before you contact HP Be sure to have the following information available before you call HP: Technical support registration number (if applicable) Product serial number Product model name and number Applicable error messages Add-on boards or hardware Third-party hardware or software Operating system type and revision level Technical support 31

32 Acronyms and abbreviations PDU power distribution unit Acronyms and abbreviations 32

33 Index A alarm operating conditions 20 C cables 28 Canadian notice 28 checking the circuit breakers 18 components 6, 19 current alarms 21 D Declaration of Conformity 27 E environmental specifications 25 European Union notice 28 external grounding point 18 F Federal Communications Commission (FCC) notice 26, 27 front panel display 19 front panel display scroll button 20 front panel LEDs 19 N normal operating conditions 20 number of outlets 24, 25 O output ratings 24, 25 overview of installation process 8 R regulatory compliance notices 26, 28 required tools 9 S S S safety information 8 specifications 23 V voltage alarms 21 I input ratings 23, 24 installation instructions 8 installing, alternative mount position 16 installing, standard mount position 10 inverting the numerical display 20 K kit contents 9 M model information 6 Index 33

safety & regulatory information

safety & regulatory information safety & regulatory information Document Part Number: 338610-001 Sixth Edition June 2006 This guide provides safety and regulatory information that is compliant with U.S., Canadian, and International regulations.

More information

3M Benchtop Air Ionizer 963E. User s Guide

3M Benchtop Air Ionizer 963E. User s Guide 3M Benchtop Air Ionizer 963E User s Guide 1 Table of Contents Section Page Safety Information...3 1. Description...4 2. Performance...4 3. Power Requirements...4 4. Installation...4 5. Operation...5 6.

More information

SEE DISCLAIMER ON REVERSE

SEE DISCLAIMER ON REVERSE BOLTEK CORPORATION Lightning Detection GSM-1 Text Message Notification for EFM-100C Electric Field Monitor User Guide SEE DISCLAIMER ON REVERSE BOLTEK LIGHTNING DETECTION GSM-1 Text Message Alert Dialer

More information

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

INSTALLATION GUIDE. AXIS A1001 Network Door Controller INSTALLATION GUIDE AXIS A1001 Network Door Controller Liability Every care has been taken in the preparation of this document. Please inform your local Axis office of any inaccuracies or omissions. Axis

More information

COMSPHERE 48 Vdc CENTRAL OFFICE POWER UNIT

COMSPHERE 48 Vdc CENTRAL OFFICE POWER UNIT COMSPHERE 48 Vdc CENTRAL OFFICE POWER UNIT INSTALLATION GUIDE Document No. 3000-A2-GB41-50 October 2002 COMSPHERE 48 Vdc Central Office Power Unit COMSPHERE 48 Vdc Central Office Power Unit Installation

More information

INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER

INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER 273 Branchport Avenue Long Branch, N.J. 07740 (908) 222-6880 INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER GENERAL: The Series PA-250 and PA-500 Watt Booster Amplifiers are designed

More information

ShockLink. Important Product Information.

ShockLink. Important Product Information. EN ShockLink Important Product Information www.laerdal.com English ShockLink Important Information Warnings and Cautions A Warning states a condition, hazard, or unsafe practice that can result in serious

More information

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE K3179V2 2/11 Rev. A ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE FEATURES The ADEMCO 4208SNF Universal Class A Module can be used in either of two different applications.

More information

Optima ZigBee Thermostat

Optima ZigBee Thermostat Optima ZigBee Thermostat Quick Start Guide For other language versions, please visit: www.salusinc.com LET S GET STARTED Make sure you have the following items: Thermostat with Mounting Plate Trim Plate

More information

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series Installation Guide INTRODUCTION Welcome and from all of us at Carrier, thank you for purchasing your new Côr thermostat: the

More information

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005 Model SWH-4000 Multi-Technology Mullion 125 KHz and 13.56 MHz (Flex) Reader Installation Guide Version A0 Part Number UM-104 September 2005 1 CONTENTS Introduction................................................

More information

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens.

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens. User Guide Luxxor 35 LED Light Source 207 Tremont Street, Rochester, New York 14608 800.536.0790 Fax: 585.235.6645 REV. 0116 gradientlens.com warnings & cautions Warnings & Cautions PORTABLE CAMERA Luxxor

More information

40 Built-in Electric Fireplace Operating and Installation Instructions

40 Built-in Electric Fireplace Operating and Installation Instructions 40 Built-in Electric Fireplace Operating and Installation Instructions This manual is for use with Furrion FF40S15A-BL 40 Built-in Electric Fireplace 1 Welcome Furrion FF40S15A-BL 40 Built-in Electric

More information

F261 Series Fluid Flow Switches

F261 Series Fluid Flow Switches F261 Series Fluid Flow Switches Product Bulletin Code No. LIT-12011987 Issued July 22, 2015 Refer to the QuickLIT website for the most up-to-date version of this document. The F261 Series Flow Switches

More information

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions x3 #8-32 x 5/16" Machine screws x4 #7 wood & #8-32 machine x 20mm Combination screws x2 M6x47mm Long through bolt 1 Preparing

More information

KONICA MINOLTA GP-502 OPERATION MANUAL

KONICA MINOLTA GP-502 OPERATION MANUAL KONICA MINOLTA GP-502 OPERATION MANUAL Rev 1.0 February 2012 Table of Contents 1. Safety 2. Overview 2.1 Features & Benefits of GP-502 2.2 Ellipse Binding Elements 2.3 User Interface & Feature Locations

More information

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description. USER GUIDE TB-9022 Iron Man Plus Workstation Monitor Installation, Operation and Maintenance Features and Components Made in the United States of America A B C D Figure 1. Iron Man Plus Workstation Monitor

More information

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0 Electric Fireplace Factory Model: EF-30D CONSUMER SAFETY INFORMATION Read this manual before installing and operating this appliance Failure to follow these instructions may result in electric shock, fire

More information

The Digital Door Viewer! User Manual. Motion Activated Sensor MAS 100

The Digital Door Viewer! User Manual. Motion Activated Sensor MAS 100 The Digital Door Viewer! User Manual Motion Activated Sensor MAS 100 01- MAS100 Thank you for purchasing Motion Activated Sensor for Brinno PeepHole Viewer! Brinno MAS100 is an extension accessory for

More information

Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator

Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator Quick Start Guide Product Features Quiet Operation Temperature Uniformity SilverPoint Enabled Local and Remote Alarms Stable Temperature Control

More information

RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions

RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following

More information

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions VT9930WDM VT9930WDM-R3 VR9930WDM VR9930WDM-R3 IFS Fiber Module Installation & Operation Instructions P/N 1062791 REV B ISS 01JUL11 VT/VR9930WDM RS - 232 DATA 1 2 3 4 5 6 7 8 20 Data Input Data Output Ground

More information

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions VAT1200 VAT1200-R3 VAR1200 VAR1200-R3 IFS Fiber Module Installation & Operation Instructions P/N 1062830 REV B ISS 01JUL11 NOTE: For an unbalanced audio input connection tie pin 1 to pin 2 and utilize

More information

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005 Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide Version A0 Part Number UM-102 September 2005 1 CONTENTS Introduction................................................

More information

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE ITM. / ART. 1165831 Model: LM56123 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY For assistance with assembly or installation,

More information

Disclaimer. Trademarks. Copyright. Warranty

Disclaimer. Trademarks. Copyright. Warranty 1 Disclaimer Trademarks Copyright Control4 makes no representations or warranties with respect to any Control4 hardware, software, or the contents or use of this publication, and specifically disclaims

More information

Cisco TelePresence MCU 4200 Series safety and compliance information

Cisco TelePresence MCU 4200 Series safety and compliance information Cisco TelePresence MCU 4200 Series safety and compliance information On this page: Safety information symbols Operating guidelines Safety warnings Technical specifications Compliance information WEEE information

More information

Performance Thermal Binder

Performance Thermal Binder Performance Thermal Binder TM Helios 60 E F S Please read these instructions before use. Lire ces instructions avant utilisation. Lea estas instrucciones antes de usar la máquina. INDEX LAMINATOR CONTROLS

More information

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions DT00 DT00-R DT0 DT0-R IFS Fiber Module Installation & Operation Instructions DR00 DR00-R DR00 DR00-R P/N 0 REV B ISS 0AUG DT00 CONTACT WHEN ON CHANNEL CONTACT TRANSMITTER ifs International Fiber Systems

More information

Clean Base Automatic Dirt Disposal. For Roomba i Series Robot Vacuums. Owner s Guide

Clean Base Automatic Dirt Disposal. For Roomba i Series Robot Vacuums. Owner s Guide Clean Base Automatic Dirt Disposal For Roomba i Series Robot Vacuums Owner s Guide Safety Information Important Safety Information This owner's guide includes information for Regulatory Model(s): ADE-N1

More information

Network Camera. Quick Guide DC-T1233WHX. Powered by

Network Camera. Quick Guide DC-T1233WHX. Powered by Network Camera Quick Guide DC-T1233WHX Powered by Safety Precautions WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE

More information

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions Before you begin DOWNLOAD THE BILT APP for step-by-step installation instructions & to register your product

More information

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216)

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216) Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216) Optional Network Module x3 #8-32 x 5/16" Machine screws x4 #7 wood & #8-32 machine x 20mm Combination

More information

ADT. Pulse 2017ADT LLC

ADT. Pulse 2017ADT LLC ADT Pulse Interactive Solutions DBC835 Wirelesss HD Doorbell Cameraa Quick Installation Guide Property of ADT, LLC. Information accurate as of published date and is provided as is without warranty of any

More information

Please Keep This Manual For Future Reference REV.01

Please Keep This Manual For Future Reference REV.01 ELCG347 ELCG240 1-855-571-1044 Please Keep This Manual For Future Reference REV.01 IMPORTANT INFORMATION When using electrical appliances, basic precautions should always be followed to reduce the risk

More information

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions VAT7420 VAT7420-R3 VAT7430 VAT7430-HP VAT7450 VAT7450-R3 VAT7450-HP IFS Fiber Module Installation & Operation Instructions VAR7420 VAR7420-R3 VAR7430 VAR7430-R3 VAR7450 VAR7450-R3 P/N 1062829 REV B ISS

More information

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions VT6010 VT6010-R3 VR6010 VR6010-R3 IFS Fiber Module Installation & Operation Instructions P/N 1062796 REV B ISS 01JUL11 4 BNC Cables (Input from cameras) VT6010A 4 CHANNEL VIDEO TRANSMITTER 1-2 - VIDEO

More information

Little Anne. Important Product Information

Little Anne. Important Product Information EN Little Anne Important Product Information English Little Anne This Important Product Information covers Little Anne, Little Anne AED and Little Anne QCPR. Unless otherwise specified the information

More information

Pet Immune SAW PIR Motion Sensor

Pet Immune SAW PIR Motion Sensor PET Immune SAW PIR Motion Sensors Installation Sheet Description This is the Installation Sheet for SAW PIR and PET Immune Motion Sensors. See Table 1. Table 1: Motion Sensors 60-807-95R 60-807-01-95R

More information

EW 40 Wireless Fan Control

EW 40 Wireless Fan Control Installation & Operating Manual EW 40 Wireless Fan Control USA CAN Product Information... Chapters 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

P266 Series Single-Phase Condenser Fan Speed Control

P266 Series Single-Phase Condenser Fan Speed Control P266 Series Single-Phase Condenser Fan Speed Control Product Bulletin P266xxx-x Code No. LIT-12011534 Issued June 24, 2009 The P266 Single-Phase Condenser Fan Speed Control is a cost-effective, weather-resistant,

More information

Light Level Detector, Surface Mount 5754PE. Installation Instructions

Light Level Detector, Surface Mount 5754PE. Installation Instructions Light Level Detector, Surface Mount 5754PE Contents 1.0 Introduction 3 2.0 Safety and Product Handling 3 3.0 Installation 4 3.1 Removing the Top Cover 4 3.2 Installing the Mounting Hardware 4 3.3 Mounting

More information

Instruction Manual. Satellite Switched, Power Monitoring Unit. RS2 Series

Instruction Manual. Satellite Switched, Power Monitoring Unit. RS2 Series Instruction Manual Satellite Switched, Power Monitoring Unit RS2 Series Geist. 1821 Yolande Ave., Lincoln, NE 68521 800.432.3219 402.474.3400 F: 402.474.4369 www.geistglobal.com Contents Contents... 2

More information

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions D1300 D1300-R3 D2300 D2300WDM D2300CP D2300SHR IFS Fiber Module Installation & Operation Instructions P/N 1062852 REV ISS 01AUG11 D1300 / D2300 / D2300SHR 2 - Wire RS485 Connection 4 3 2 1 No Connection

More information

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions QUICK LINKS Mounting Location Guidelines Open the Sensor Mount the Sensor Sensor Components and Settings Wire the Sensor Wiring

More information

Blueair C User Manual

Blueair C User Manual Blueair C User Manual Before using Blueair Classic 200 series, please read this user manual carefully. Note: There may be local variations of these models. Contents General 4 Overview of unit 5 Adjusting

More information

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd. Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd. Copyright Clipsal Australia Pty Ltd, 2008. All rights reserved. This material is copyright

More information

programmable control model installation and setup guide M /11/ Hunter Fan Company

programmable control model installation and setup guide M /11/ Hunter Fan Company programmable control model 99107 installation and setup guide installation Prior to installation, download the app to ensure phone compatibility: Visit your app store and search simpleconnect to find the

More information

Table of Contents. What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide With Ring, you re Always home.

Table of Contents. What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide With Ring, you re Always home. Chime Setup Guide Table of Contents 2 What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide... 6 With Ring, you re Always home. What s in the Box 3 1. Ring Chime 2. Wall plugs

More information

Safety Instructions. Be sure to observe the following instructions when using the device.

Safety Instructions. Be sure to observe the following instructions when using the device. Safety Instructions Be sure to observe the following instructions when using the device. Warning: Failure to observe the instructions may lead to death or serious injury. Directly plug the power cord in

More information

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions IFT-RC150 IntelliFire Touch Remote Control Installation Instructions Leave this manual with party responsible for use and operation. 1. Introduction The IFT-RC150 is a wall mounted device that is designed

More information

APC BC300 Series 40kW 208/450/480V User Guide

APC BC300 Series 40kW 208/450/480V User Guide APC BC300 Series 40kW 208/450/480V User Guide Copyright 2002 APC Denmark ApS This manual is subject to change without notice and does not represent a commitment on the part of the vendor Thank You Thank

More information

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1 GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E Figure 1 PET OWNERS WARNING: Health warning for some small pets, including birds, as they are extremely sensitive to the fumes produced

More information

SYSTEM ENHANCEMENT MODULE

SYSTEM ENHANCEMENT MODULE SYSTEM ENHANCEMENT MODULE DSC PowerSeries INSTALLATION GUIDE INSTALL WIZARD AVAILABLE AT ALARM.COM/SEMPOWERSERIES OVERVIEW The System Enhancement Module (SEM) can be used with DSC PowerSeries PC1616, PC1832,

More information

Operation and Maintenance Manual

Operation and Maintenance Manual M0075640-01 (en-us) September 2016 Operation and Maintenance Manual Product Link PLG641 and PLG601 for Generator Systems PL6 1-UP (Machine Control & Guidance Products) SAFETY.CAT.COM Important Safety Information

More information

Honeywell Temperature & Humidity Sensor with LCD

Honeywell Temperature & Humidity Sensor with LCD Honeywell Temperature & Humidity Sensor with LCD TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW 4 BEFORE YOU BEGIN 5 BATTERY INSTALLATION 7 LOW BATTERY WARNING 7 PLACEMENT OF THE REMOTE SENSOR 7 GETTING

More information

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver. LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: 7131720 ver.b 1 1 General... 3 2 Features... 3 3 Assembly description...

More information

MILLA ELECTRIC FIREPLACE

MILLA ELECTRIC FIREPLACE MILLA ELECTRIC FIREPLACE MODEL NO. 064-3177-0 ASSEMBLY INSTRUCTIONS Toll-free: 1-888-670-6684 IMPORTANT: Please read this manual carefully before beginning assembly of this product. Keep this manual for

More information

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003 QUICK START GUIDE Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003 Welcome. This guide will help you install your Lono controller. For additional information, check out our installation

More information

Universal Fan and Light Remote Control

Universal Fan and Light Remote Control Universal Fan and Light Remote Control Hand-Held Remote and Wall Cradle Owner s Guide and Installation Manual English Form# 41316-01 20100930 2010 Hunter Fan Co. 1 Welcome Table of Contents Read and Save

More information

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver Power Distribution Unit for IP-NINJAR PDU-1209 User s Guide Ver. 1.0.0 Thank you for choosing this IDK product. To ensure the best performance of this product, please read this User s Guide fully and carefully

More information

Agilent N4011A MIMO/Multi-port Adapter

Agilent N4011A MIMO/Multi-port Adapter Agilent N4011A MIMO/Multi-port Adapter Getting Started Guide Agilent Technologies Notices Agilent Technologies UK Ltd. 2007, 2009 No part of this manual may be reproduced in any form or by any means (including

More information

Honeywell. Wireless Rain Gauge with Indoor. Temperature (TC152) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW 4 REMOTE RAIN GAUGE 7

Honeywell. Wireless Rain Gauge with Indoor. Temperature (TC152) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW 4 REMOTE RAIN GAUGE 7 TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW 4 REMOTE RAIN GAUGE 7 BEFORE YOU BEGIN 9 BATTERY INSTALLATION 10 LOW BATTERY WARNING 11 HOW TO USE THE TABLE STAND 11 GETTING STARTED 11 Honeywell Wireless

More information

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide P/N 1072921 REV A ISS 10FEB15 Contents Product overview 2 Camera description 3 Installation 4 Programming 6 Specifications 7 Setup menu

More information

Wireless Outdoor Air Reset Adaptor PN:

Wireless Outdoor Air Reset Adaptor PN: Wireless Outdoor Air Reset Adaptor PN: 105767-01 Instruction Sheet APPLICATION The Wireless Outdoor Air Reset Adaptor, when connected to the Concert Boiler Control enables efficiency control functionality

More information

VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions

VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions P/N 1062814 REV B ISS 01JUL11 Video source Coax cable VT1101M VIDEO TX ifs 3 +9-12VDC 2 GRD 1 Contact input Black with white stripe

More information

4 MP HDCVI PTZ In-ceiling Camera

4 MP HDCVI PTZ In-ceiling Camera 4 MP HDCVI PTZ In-ceiling Camera 52C430IC Quick Start Guide Version 001.001 Dahua Technology USA Inc. Table of Contents 1 Welcome... 1 1.1 Important Safeguards and Warnings... 1 Electrical safety... 1

More information

Towel Warmer MAKE EVERYDAY A SPA DAY

Towel Warmer MAKE EVERYDAY A SPA DAY Towel Warmer MAKE EVERYDAY A SPA DAY TABLE OF CONTENTS Warnings and Cautions....1 FCC Information...4 Location of Parts and Controls...6 Set Up... 7 Using the Towel Warmer....8 Selecting the Timer...9

More information

BE1310 Visit Smart hub

BE1310 Visit Smart hub EN BE1310 Visit Smart hub Contents Setting up the Smart hub 3 Before you start 4 Installation 5 Pairing 6 Testing 8 Welcome home signal 9 Troubleshooting 10 Setting up monitors 11 Telephone monitor 13

More information

Projection Alarm Clock USER GUIDE

Projection Alarm Clock USER GUIDE Projection Alarm Clock USER GUIDE Jazwares, Inc. 2012 CONTENTS Please read the instructions along with the Alarm Clock carefully before you use it, so that you can operate it conveniently. WELCOME, Warnings

More information

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100 GETTING STARTED GUIDE NI 9217 4 RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100 This document explains how to connect to the NI 9217. Note Before you begin, complete the software and hardware installation

More information

COMBINATION ELECTRIC FIREPLACE/HEATER Model #FP23-1A-AKM

COMBINATION ELECTRIC FIREPLACE/HEATER Model #FP23-1A-AKM LOT NUMBER: DATE PURCHASED: / / USE AND CARE GUIDE COMBINATION ELECTRIC FIREPLACE/HEATER Model #FP23-1A-AKM If you have any questions regarding the use of this unit, or find that your fireplace/heater

More information

Towel Warmer. Luxurious warmth for towels, robes and blankets

Towel Warmer. Luxurious warmth for towels, robes and blankets Towel Warmer Luxurious warmth for towels, robes and blankets Table of contents Warnings and Cautions................................................... 2 Location of Controls......................................................

More information

POWERED ANODE SYSTEM

POWERED ANODE SYSTEM POWERED ANODE SYSTEM USER S GUIDE MODULE ANODE ELECTRODE Table of Contents Page SAFETY... 2 WIRING DIAGRAM... 2 INTRODUCTION... 3 INSTALLATION... 4 SYSTEM FEEDBACK... 6 REGULATORY NOTICES... 6 SPECIFICATIONS...

More information

TEC2100 Series Networked Thermostats

TEC2100 Series Networked Thermostats Product Bulletin Issue Date February 11, 2004 TEC2100 Series Networked Thermostats The TEC2100 Series of thermostats is a family of highly advanced thermostats specifically designed for control of equipment

More information

Owner s Manual. PIR-1 IR Learner

Owner s Manual. PIR-1 IR Learner Owner s Manual PIR-1 IR Learner PIR-1 Owner s Manual 2010-2013 Universal Remote Control, Inc. The information in this owner s manual is copyright protected. No part of this manual may be copied or reproduced

More information

Installation Manual. Wiegand Interface Unit Four-State (WIU-4) North America T F Asia T F

Installation Manual. Wiegand Interface Unit Four-State (WIU-4) North America T F Asia T F North America T 888 437 3287 F 561 998 6224 Asia T 65 639 19314 F 65 639 19306 Wiegand Interface Unit Four-State (WIU-4) Installation Manual Australia T 61 3 9239 1200 F 61 3 9239 1299 Canada T 800 267

More information

Failure to comply with the following instructions may result in death or serious injury to

Failure to comply with the following instructions may result in death or serious injury to 1. Safety Precautions [Warning] Failure to comply with the following instructions may result in death or serious injury to the user or failure of the product. - Do not disassemble, repair, or modify the

More information

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate GETTING STARTED GUIDE NI 9213 16 TC, ±78 mv, 24 Bit, 75 S/s Aggregate This document explains how to connect to the NI 9213. Note Before you begin, complete the software and hardware installation procedures

More information

Twin Bell Digital Clock

Twin Bell Digital Clock Twin Bell Digital Clock Model: V50-500 Instruction Manual PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USE AND KEEP IT FOR FUTURE REFERENCE. SPECIFICATIONS... 1 SAFETY INSTRUCTIONS... 2 FUNCTIONS...

More information

WatchDog Wireless Crop Monitor Operation Manual

WatchDog Wireless Crop Monitor Operation Manual WatchDog Wireless Crop Monitor Operation Manual Spectrum Technologies, Inc. CONTENTS General Overview 3 Accessories 4 System Configuration 5 Configuring the Monitoring Unit 7 Powering Up the Unit 7 LED

More information

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions DECT000 DECT00 DECT00 DECR000 DECR00 DECR00 IFS Fiber Module Installation & Operation Instructions P/N 00 REV B ISS 0AUG DECT00 CHANNEL LNK ACT TX RX 00FX CONTACT CLOSED WHEN ON CONTACT TO ETHERNET TRANSMITTER

More information

Wireless Rain Gauge with Indoor Temperature

Wireless Rain Gauge with Indoor Temperature TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW 4 7 BEFORE YOU BEGIN 9 BATTERY INSTALLATION 10 Wireless Rain Gauge with Indoor Temperature LOW BATTERY WARNING 11 HOW TO USE THE TABLE STAND 11 GETTING

More information

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual Table of Contents 1. Introduction... 2 2. Getting Started... 2 2.1 Parts List... 2 2.2 Recommend Tools... 2 2.3 Thermometer Sensor

More information

With Remote Control. English

With Remote Control. English Infrared Heater With Remote Control, Owner s Manual English Model H1500RC-CHY H1500RC-BLK INTRODUCTION Thank you for choosing the Hunter Infrared Heater. This manual gives you complete instructions for

More information

HDCVI PTZ Camera. 6C Series. Quick Start Guide Version Dahua Technology USA Inc.

HDCVI PTZ Camera. 6C Series. Quick Start Guide Version Dahua Technology USA Inc. HDCVI PTZ Camera 6C Series Quick Start Guide Version 001.002 Dahua Technology USA Inc. Table of Contents 1 Welcome... 1 1.1 Important Safeguards and Warnings... 1 Electrical safety... 1 Environmental Precautions...

More information

IFS Fiber Module Installation & Operation

IFS Fiber Module Installation & Operation T1000 T1000-R3 T1020 T1020-R3 T1025 T1025-R3 R1000 R1000-R3 R1030 R1030-R3 R2000 R2000-R3 R2020 R2020-R3 R2025 R2025-R3 R2010WDM R2010WDM-R3 R2010WDMB R2010WDMB-R3 IFS Fiber Module Installation & Operation

More information

Low Voltage Fan Coil Thermostat ST101ZB. Quick Start Guide. For other language versions, please visit

Low Voltage Fan Coil Thermostat ST101ZB. Quick Start Guide. For other language versions, please visit Low Voltage Fan Coil Thermostat ST101ZB Quick Start Guide For other language versions, please visit www.salusinc.com Notices Please read these instructions carefully before installing and using the Low

More information

MAJIK ENGLISH 11/20/02 11:30 AM Page 1 M A J I K O W N E R S M A N U A L

MAJIK ENGLISH 11/20/02 11:30 AM Page 1 M A J I K O W N E R S M A N U A L MAJIK OWNERS MANUAL i MAINS PLUGS This appliance is supplied with a non-rewireable mains plug for the intended country. Replacement mains leads can be obtained from your Linn retailer. Should you need

More information

FTP-1000 Touchpad/Display Installation Manual

FTP-1000 Touchpad/Display Installation Manual FTP-1000 Touchpad/Display Installation Manual A B 1 2 3 4 5 6 7 8 9 0 * # Stay Away Disarm Quick Exit C D P/N 466-2231 REV B January 2011 Copyright Disclaimer Trademarks and patents Manufacturer Intended

More information

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE INSTALLATION AND OPERATION INSTRUCTIONS MODEL NUMBER NXSMP-LMI PRECAUTIONS Read and understand all instructions before beginning installation. CAUTION: FOR USE

More information

Installation Instructions

Installation Instructions Installation Instructions S E C U R I T Y S Y S T E M Please refer to the System Installation Manual for information on limitations regarding product use and function and information on the limitations

More information

Wireless Home Appliance Timer Remote Control Kit

Wireless Home Appliance Timer Remote Control Kit Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user authority to operate the equipment. NOTE : This equipment has been tested

More information

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date: Installation and Operating instructions for C9900-U330-0010 battery pack Version: 2.0 Date: 2017-03-23 Table of contents Table of contents 1 Foreword 3 1.1 Notes on the Documentation 3 1.1.1 Liability

More information

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L C-Bus PIR Occupancy Sensor Installation Instructions 5751L Contents 1.0 Description 3 2.0 Important Notes 3 3.0 Installation 3 4.0 C-Bus Network Connection 6 5.0 Programming and Setup 7 6.0 Troubleshooting

More information

GETTING STARTED GUIDE NI DI, 30 V, Sourcing, 7 μs

GETTING STARTED GUIDE NI DI, 30 V, Sourcing, 7 μs GETTING STARTED GUIDE NI 9426 32 DI, 30 V, Sourcing, 7 μs This document explains how to connect to the NI 9426. Note Before you begin, complete the software and hardware installation procedures in your

More information

HDCVI PTZ Network Camera

HDCVI PTZ Network Camera HDCVI PTZ Network Camera 59 Series Quick Start Guide Version 001.002 Dahua Technology USA Inc. Table of Contents 1 Welcome... 1 1.1 Important Safeguards and Warnings... 1 Electrical safety... 1 Environmental

More information

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265.

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265. GETTING STARTED GUIDE NI 9265 4-Channel, 0 ma to 20 ma, 16-Bit Analog Output Module This document explains how to connect to the NI 9265. Note Before you begin, complete the software and hardware installation

More information

CONNEX Smart Thermostat CST R00

CONNEX Smart Thermostat CST R00 CONNEX Smart Thermostat CST-240 7215100100R00 Table of Contents Welcome... 3 Features... 5 Specifications... 5 Selecting the Heater Type... 5 Installation... 7 Control Panel (User Interface)... 9 Operation...

More information

FV-11VQL6. Thank you for purchasing this Panasonic product Back cover FV-15VQL6

FV-11VQL6. Thank you for purchasing this Panasonic product Back cover FV-15VQL6 FV-08VQL6 FV-15VQL6 FV-11VQL6 2-3 5 5 6-8 FV-08VQL6 FV-11VQL6 11 Back cover Back cover Back cover FV-15VQL6 Thank you for purchasing this Panasonic product. For Your Safety To reduce the risk of injury,

More information