OKM 801INFANT INCUBATOR

Size: px
Start display at page:

Download "OKM 801INFANT INCUBATOR"

Transcription

1 OKM 801INFANT INCUBATOR

2 OKM 801 INFANT INCUBATOR 02 OKM 801 Infant Incubator Premature and / or infants which might have serious health problems after delivery they need close caring of the physician and the nurses because they are not capable to keep their body temperature at the required level and stability by their own. Besides the medical cure, in order to improve health conditions; patients need a fresh air in a steril environment with constant temperature and appropriate humidity as well as silence which do not interrupt their sleep. Also have optional Haemodynamic monitoring features alongwith additional external display. Simple viewing of all modes and applicable set values of the parameters. OKM 801 Infant Incubator is specially designed with high technology to meet all necessary requirements and makes difference in NICU.

3 Stable With ambient temperature probe OKM 801 infant incubator is able to compare the difference between ambient and setting temperature, and changing heating power output accordingly in order to provide more stable inside hood air temperature. The micro processor controlled unit has automatic Self test function. Skin temperature monitoring through Reusable & Disposable sensor Air circuit temperature monitoring More accurate temperature control and safer system Temperature 1 Connector Temperature 2 Connector Minimize Temperature Uniformity OKM 801 incubator s air circuit system is designed based on massive experimentation. With plenty aerodynamics knowledge the temperature uniformity is improved as much as possible in order to give infant the safest micro-environment. Allows the temperature to be monitored on two different (T1 and T2) points of the body for more accuracy to maintain targeted temperature level. Super Quiet Design It is approved that in addition to the direct auditory effects of noise, noise also influences the cardiovascular system, the respiratory system, sleep patterns, and stress levels of neonates. OKM 801 provides newborn a super quiet environment, hood sound is reduced to 45dB. Detachable Sensor Module Sensor module is connected with incubator main body 20 pin connector. During maintenance and service it can be removed easily. Three Channel Temperature Sensors There are three channel of temperature sensors in the module box. One channel is for reading hood temperature to remain the temperature at setting value. Another temperature sensor is used to compare the reading with other two sensors. If the reading of three sensors differ from 0.8 C, alarm is triggered. OKM 801 with External Screen/ Haemodynamic Monitor Humidity Sensors Humidity sensor is for reading humidity level in incubator. When the water level is low in the autoclavable water reservoir, an audible and visual Low Humidity alarm occurs. Oxygen Sensors (Optional) The oxygen control system adjusts the flow of oxygen within the incubator hood with a valve and an oxygen sensor module. The sensor module has two independent oxygen fuel cells. When the sensor module is outside of the hood during Oxygen Control mode, audible and visual alarms are enabled, and the flow of oxygen is interrupted. Temperature and Humidity Sensor Oxygen Sensor (Optional) 03 Backup Battery OKM 801 is equipped with backup battery, once power supply is off, the backup battery supports the air circuit and alarm system to keep working at least 30 minutes. Also external monitor with haemodynamic parameters will have a separate power backup.

4 8 Color LCD Touchscreen display provides all incubator parameter users to operate soft buttons as well as touchscreen Touchscreen OKM 801 Infant Incubator 04 Can be operated from both side of hood Ergonomic designed handle with perfect height 1,5 liter water reservoir enables OKM 801 to keep running for 36 hours. Big storage drawers Detachable water reservoir, easy to clean and sterilize Three auxiliary power output Optional Height Adjustment Haemodynamic Monitor with essential Incubators parameters. Tente castor with lock

5 Other Features / Air Curtain While the front or back access panels open, the air circuit motor rotation rate is accelerated automatically. Therefore more warm air is delivered to the hood. It effectively prevent heat lose and provide infant stable micro-environment. Haemodynamic Monitor Double Wall Design Air Curtain Alarm Audio & Visual Display Temperature Monitoring and Protection Alarms OKM 801 infant incubator monitor and control temperature on various points on heating system to ensure accuracy and safety. The alarms will be actived if any unmoral phenomenon is monitored. High Skin Temperature Low Skin Temperature High Skin 1 Temperature High Skin 2 Temperature Skin Probe Disconnect High Air Temperature Low Air Temperature Electronic circuit fault as High Temperature Cut Out Sensor Monitoring Alarms OKM 801 incubator monitors the condition of air, humidity, oxygen sensors, air flow probes and sensor box to ensure all the data collected are true and accurate. Alarms are triggered when any errors related to the operation of the sensors are detected. Humidity Heater Failed Add water Low Humidity (moisture) Reservoir Out Of Position Oxygen Cell Difference Low Oxygen Ratio High Oxygen Ratio Check O2 Supply Servo O2 System Fail Change Oxygen Cells High Spo2 alarm Low Spo2 alarm External display failure alarm Separate Haemodynamic parameters failure alarms Working Condition Monitoring Alarms In order to keep proper running and provide the best user ecperience, OKM 801 infant incubator monitors the working condition of each aspect. 05 Motor Failed Power Failure Stuck Key Sensor Module Failure Sensor Disconnect Low Air Flow Air Flow Probe Failed Battery Disconnect Sensor Out of Position Access Panel Open Heater Failed Air Probe Failed Skin1 Probe Fail Alarm SpO2 sensor Fail Alarm Watchdog Failed

6 GENERAL SPECIFICATIONS Height 126.1cm to 146.1cm Tubing Access Ports 10 Width 99.7 cm Access Door Size 18x13 cm (Max. 6 doors) Depth 57.7cm Mattress to Hood Height 48.0 mm Weight 80 kg Soft Bed Mattress Size (Bed safety mechanism Package Dimensions 107*68*155 cm active when pulled outside) X-Ray Tray 41 x 38.9 cm Trendelenburg ± cm2 standard (upto 77 x 40cm/ 3080cm2 on request) 06 TEMPERATURE CONTROL MODES OKM 801 Infant Incubator External Display for Incubator & Haemodynamic parameters (Optional) Power Supply and Frequency Temperature Control Modes Air Mode Control Temperature Range Air Mode Control Override Temperature Range Air Mode Control Accuracy Skin Mode Control Temperature Range Heat Cut of Temperature 8, 10 or 12 inches colour TFT VAC and 50/60 Hz Hood cover opening Display of Parameters Trend Display Air Filter (Replacable) Skin and Air Temperature Control Modes 20 C-37 C 39 C-40 C ±1.0 C 34 C-37.5 C 40 C ± 0.8 C 180 (Both Front & back) Active & set values 2,4,8,12,24 Hours Min. 0.3 to Max. 0.5 macron Skin Mode Control Override Temperature Range Skin Temperature Accuracy Dual-Skin Temperature Monitoring 37.5 C-39 C ±0.3 C Yes PERFORMANCE Air Flow Velocity Across Mattress Temperature Rise Time At 22 C (72 F) Ambient < 10 cm/sec <20min (From 22 C, 50% RH, to 35 C) Temperature Variability < 0.5 C Temperature Overshoot < 0.5 C Maximum Temperature Uniformity With A Level Mattress < 0.8 C Operating Noise Level In Hood 45dBa Carbon Dioxide (Co2) Level <0.5% SERVO HUMIDITY (OPTIONAL) With AutoClean Function of Autoclavable Chamber Humidity Control Range Humidity Control Operating Time Without Refilling Humidity Control Reservoir Capacity Humidity Display Accuracy Humidity Control Accuracy 30% - 95% RH 24 hours 1500 ml ±5% RH ±5% RH

7 DIGITAL OXYGEN DISPLAY / SERVO CONTROLLED OXYGEN (OPTIONAL) Oxygen Control Range 21% to 65% Oxygen Display Accuracy Of Full Scale ± 2% Oxygen Control Accuracy (100% Calibration) ± 3% Oxygen Control Accuracy (21% Calibration) ± 5% Oxygen Display Resolution 1% SCALE (OPTIONAL) Weight Range Weight Display Resolution Weight Accuracy 300 g to 8 kg 1 g ±10 g Operating Environment 20 to 30 C Temperature Air Velocity 10 to 95% RH Up to 0.1 m/sec SpO2 with HAEMODYNAMIC MONITOR (OPTIONAL) Parameters SpO2, PR, PI, PVI, SpCO, SpOC, SpMet, SpHb Mesurement Range 0 to 100 % Perfusion Index % Haemo parameters on External screen PR, NIBP, SpO2, Temp, EtCO2 STORAGE/SHIPPING INFORMATION Temperature -25 to 60 C Humidity to 95 % RH

8 2018 OKUMAN Medikal Sistemler A.S. All rights reserved. Technical specifications are subject to change by OKUMAN without prior notice. OKUMAN Medikal Sistemler A.S. Kazım Karabekir Caddesi 95/ Iskitler Ankara / TURKEY T: F: info@okuman.com.tr Catalog No: OKM EN

BiliCare INTENSIVE PHOTOTHERAPY

BiliCare INTENSIVE PHOTOTHERAPY BiliCare INTENSIVE PHOTOTHERAPY BiliCare INTENSIVE PHOTOTHERAPY The efficiency of phototheapy depends on the amount of bilirubin that is irradiated. BiliCare distribute better and ho-mogeneous light penetration

More information

BT-500. Infant Incubator. BT-500 Infant Incubator

BT-500. Infant Incubator. BT-500 Infant Incubator Infant Incubator BT-500 Accurate humidity control Comfortable and soft tilting structure 7 TFT color LCD display Various alarm function (27 events) Low noise hood MASIMO SpO2 and CCD camera Accurate weighing

More information

SPECIFICATION FOR MULTIPARAMETER MONITOR

SPECIFICATION FOR MULTIPARAMETER MONITOR SPECIFICATION FOR MULTIPARAMETER MONITOR Eight channel high resolution colour TFT display with 12.1" screen size and auto spacing User Selectable Display formats and waveform colours. ECG monitoring -

More information

CLEO VERSATILITY IN VITAL SIGNS

CLEO VERSATILITY IN VITAL SIGNS CLEO VERSATILITY IN VITAL SIGNS CLEO PORTABLE weighs less than 3 lbs TOUCHSCREEN easy and intuitive to use MOBILE backup battery powered The Cleo is a new and intuitive approach to patient vital signs

More information

Vitalmax 4000 CL Product Specifications

Vitalmax 4000 CL Product Specifications Page 1 of 5 Vitalmax 4000 CL 510 Garden Avenue North, Clearwater, FL 33755 Phone: (727) 442-8118 Fax: (727) 443-7257 A. Mechanical Description Size 10" H x 13" W x 8"D (25 cm x 33 cm x 20 cm) Weight 18

More information

OMNI Express VS VERSATILITY IN VITAL SIGNS

OMNI Express VS VERSATILITY IN VITAL SIGNS OMNI Express VS VERSATILITY IN VITAL SIGNS OMNI Express VS TOUCHSCREEN easy and intuitive to use PORTABLE weighs less than 6lbs MOBILE backup battery powered The Omni Express VS is a new intuitive approach

More information

İndex SUCTION UNIT... PATIENT MONITOR HOLTER SYSTEM... 7

İndex SUCTION UNIT... PATIENT MONITOR HOLTER SYSTEM... 7 PRODUCT CATALOGUE 1 2 İndex SUCTION UNIT... 4 PATIENT MONITOR... 5-6 HOLTER SYSTEM... Tourniquet Systems... Electrosurgical Units... Fetal MONITORS... Larygoscope Sets... Diagnostic Sets... - - 12 3 Suction

More information

EC 160 CO 2. Incubator

EC 160 CO 2. Incubator EC 160 Incubator EC 160 Incubator OPTIMIZED CULTURE CONDITIONS Reproducible and reliable cell growth is dependent upon three critical parameters, temperature, concentration and relative humidity. EC 160

More information

ENVAIR lab CO2 Tri-Gas Incubator

ENVAIR lab CO2 Tri-Gas Incubator ENVAIR lab CO2 Tri-Gas Incubator Laboratory Incubator ENVAIR lab CO2 Tri-Gas Incubator Introduction ENVAIR lab Tri-Gas Incubator, providing precise temperature, C02, 02 control as well as high humidity,

More information

Nellcor with OxiMax Technology Product Ordering Guide A Full Line of Oximetry Sensors and Monitors

Nellcor with OxiMax Technology Product Ordering Guide A Full Line of Oximetry Sensors and Monitors Nellcor with OxiMax Technology Product Ordering Guide A Full Line of Oximetry Sensors and Monitors Specialty sensors Forehead Sensor For patients with low perfusion; suitable for long-term monitoring Forehead

More information

1 Appendix - Product Specifications

1 Appendix - Product Specifications 1 Appendix - Product Specifications WARNING The patient monitor may not meet its performance specification if stored or used outside the manufacturer s specified temperature and humidity range. 1.1 Safety

More information

Ohio Care Plus Series 1000/2000 Incubator. Operation and Maintenance Manual

Ohio Care Plus Series 1000/2000 Incubator. Operation and Maintenance Manual Ohio Care Plus Series 1000/2000 Incubator Operation and Maintenance Manual Table User Responsibility of Contents This Product will perform in conformity with the description thereof contained in this operating

More information

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N Nellcor Bedside SpO 2 Patient Monitoring System, PM100N In-Service Presentation Nellcor Bedside SpO 2 Patient Monitoring System is CE marked and commercially av ailable in European Union countries. Nellcor

More information

OMNI TOUCH SCREEN PATIENT MONITOR

OMNI TOUCH SCREEN PATIENT MONITOR OMNI TOUCH SCREEN PATIENT MONITOR OMNI Intuitive Designed for a fast paced work environment, the Infinium Omni patient monitor offers an extremely simple and adaptable user interface. Patient information

More information

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring Data Sheet 907021 Page 1/9 Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring For measuring relative air humidity, temperature, and fresh

More information

Controlled Environment Equipment Solutions for the Lab

Controlled Environment Equipment Solutions for the Lab Controlled Environment Equipment Solutions for the Lab Forma Reach-In Incubator Analyze Detect Measure Control Features and Technical Specifications Forma Reach-In Incubator Uniform Performance High Capacity

More information

108A OTP1800. Grid Support. General Description

108A OTP1800. Grid Support. General Description Operation Manual 108A OTP1800 ON/OFF Main Switch On/Off Alarm Switch Digital Control Module Grid Support Alarm Fuse 250 Volt 15 amp Load Outlet Sensor Input Inlet General Description This control is a

More information

ila ACTIVVE SYSTEM PLATFORM

ila ACTIVVE SYSTEM PLATFORM ila ACTIVVE SYSTEM PLATFORM Custom-tailored Extrapulmonary Lung Support ila activve : Custom-Tailored Extrapulmonary gas exchange Extrapulmonary blood flow: as high as necessary as low as possible. The

More information

THERMOMETERS Dataloggers/Refrigerator

THERMOMETERS Dataloggers/Refrigerator Dataloggers Traceable Excursion-Trac Datalogging Refrigerator/ Freezer Thermometer Datalogging thermometer with user-deined time intervals Meets current CDC requirements for vaccine storage and monitoring

More information

Incubators THE BENCHTOP EQUIPMENT HYGIENE SOLUTION

Incubators THE BENCHTOP EQUIPMENT HYGIENE SOLUTION Incubators THE BENCHTOP EQUIPMENT HYGIENE SOLUTION 25 Incubators Stuart has a number of incubators specially designed for accurate and reproducible temperature controlled applications. All incubators have

More information

Platelet bags constant shaking for long periods of time.

Platelet bags constant shaking for long periods of time. Horizontal shakers for platelet bags APL-54 and APL-108 HORIZONTAL MOVEMENT AT A FIXED SPEED OF 66 R.P.M., LATERAL SHUFFLE OF 40 MM. APL-54 : CAPACITY FOR 54 PLATELET BAGS. APL-108 : CAPACITY FOR 108 PLATELET

More information

Professional Design Project

Professional Design Project Professional Design Project PDP 13 277 New design and development of neonatal intensive i care equipment- open radiant heat warmer with integrated pulse oxi-meter with smart control interface MSME name

More information

Incubators. with BioCote antimicrobial protection

Incubators. with BioCote antimicrobial protection Incubators with BioCote antimicrobial protection Stuart has a number of incubators specially designed for accurate and reproducible temperature controlled applications. All incubators have state of the

More information

PRODUCT TRAINING MODULE: Honeywell Zephyr Airflow Sensors HAF Series High Accuracy

PRODUCT TRAINING MODULE: Honeywell Zephyr Airflow Sensors HAF Series High Accuracy PRODUCT TRAINING MODULE: HAF Series High Accuracy Summary of Content In this training module, you will learn the following about : The 6 advantages that are not found in other airflow sensors Their key

More information

intuitive, intelligent, interactive

intuitive, intelligent, interactive intuitive, intelligent, interactive Thermo Scientific Heracell 150i and 240i CO 2 Incubators Thermo Scientific Heracell 150i and 240i CO 2 Incubators >> Surround your valuable cultures with an environment

More information

Benchtop CO 2 Incubator. the Oasis 6400 series

Benchtop CO 2 Incubator. the Oasis 6400 series Benchtop CO 2 Incubator the Oasis 6400 series USER CONVENIENCES The safest and most secure environment for your research Your cell cultures are safe and sound, regardless of frequent door openings. The

More information

Simple and Versatile

Simple and Versatile Simple and Versatile Total support from postnatal treatment to NICU care. The most suitable model can be chosen from a cost-effective line up. Cabinet/Tilt Hi-Low/Tilt Stand Ideal for use in NICU Sufficient

More information

VWR symphony CO 2 INCUBATORS

VWR symphony CO 2 INCUBATORS VWR symphony CO 2 INCUBATORS Choice Stability Protection VWR symphony INCUBATORS THE CHOICE IS YOURS The VWR symphony series provides unsurpassed performance, reliability and selection. An enhanced and

More information

BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS

BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS ARCTIKO AIMS to be the first and best choice of partner in delivering advanced and customized cooling and freezing solutions

More information

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter by Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter Technical Specifications Brouwer -86 o C Chest STORAGE SPECS UNIT -86 DFC 370-86 DFC 620-86 DFC 820 Capacity L 370 620

More information

Omni (K) PATIENT MONITOR

Omni (K) PATIENT MONITOR Omni (K) PATIENT MONITOR Omni (K) Intuitive Designed for a fast paced work environment, the Infinium Omni (K) patient monitor offers an extremely simple and adaptable user interface. Patient information

More information

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System FEATURES: HIGH GAMMA SENSITIVITY MULTI-CHANNEL ANALYZER (MCA) WORKS WITH VARIETY OF PROBES RADIONUCLIDE LIBRARY TAILORED TO CUSTOMER REQUEST SIMULTANEOUSLY MEASURES ; DISPLAYS; ALARMS 1-3 SEPARATE DETECTORS

More information

Igloo. Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Igloo. Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter Igloo Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter Igloo More samples, less footprint Laboratory space is valuable. In comparison with the traditional freezers, Telstar

More information

laboratory & sterilization technology

laboratory & sterilization technology laboratory & sterilization technology BM SERIES Circulated Water Baths Designed for many general and special applications in microbiology, research and industrial laboratories Powerful circulation by means

More information

BLOOD BANK REFRIGERATOR - BR Series

BLOOD BANK REFRIGERATOR - BR Series BLOOD BANK REFRIGERATOR - BR Series TRANSFUSION SYSTEMS ISO 13485 Optimize blood care with advanced technology The most secure environment for blood products outside the human body FEATURES BLOOD BANK

More information

The Professional Choice

The Professional Choice The Professional Choice Product Catalogue Innovation in line with your clinical requirements How do you prepare for situations that leave no room for compromise? How do you get ready for an operation

More information

Technology, Quality, Reliability and Repeatability. ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified. 1

Technology, Quality, Reliability and Repeatability. ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified.  1 Technology, Quality, Reliability and Repeatability Environmentally friendly CO2 Incubator powered by Meditech Technology for safe cells and Tissue cultures ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified.

More information

LEAKSTOPPER 1 Single zone water leak detection system

LEAKSTOPPER 1 Single zone water leak detection system LEAKSTOPPER 1 Single zone water leak detection system WHAT DOES THE PRODUCT DO? The LeakStopper 1 detects the presence of water in environments where it is not supposed to be. Should water be detected

More information

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs User Manual Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-03 and 89800-04 THE STANDARD IN PRECISION MEASUREMENT Table of Contents

More information

OGB PolyTrend (8070) Intensive Care Incubator User Manual

OGB PolyTrend (8070) Intensive Care Incubator User Manual OGB PolyTrend -User manual Rev.11 OGB PolyTrend (8070) Intensive Care Incubator User Manual Ginevri s.r.l 8070bmd 01/03/2010 1 Rev. 11 OGB PolyTrend-User manual THIS MANUAL HAS BEEN PRODUCED RESPECTING

More information

T-32-TS Touchscreen Thermostat. Installation Manual

T-32-TS Touchscreen Thermostat. Installation Manual T-32-TS Touchscreen Thermostat Installation Manual TABLE OF CONTENTS Introduction...4 Getting Started...5 Installing the Thermostat...6, 8 Disassembly...6 Thermostat Location...6 Mounting the Subbase...6,

More information

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification LMV52 Control Product Description February 3, 2017 The LMV52 is a microprocessor-based burner management system with matching system components for the control and supervision of forced draft burners.

More information

The No.1 choice for Veterinary care and animal recovery.

The No.1 choice for Veterinary care and animal recovery. The No.1 choice for Veterinary care and animal recovery. Specialized intensive care units designed for optimum comfort, care and control. cell activation Strengthen immunity Better blood flow prevention

More information

www. szcomen. com COMEN - SHARE WITH THE WORLD

www. szcomen. com COMEN - SHARE WITH THE WORLD COMEN - SHARE WITH THE WORLD Agenda COMEN - SHARE WITH THE WORLD C80 Introduce C80 Market position Hardware Software price C80 C90 C60 C30/C90A C50 STAR8000D STAR8000C STAR8000B STAR8000A Products positioning

More information

Undercounter Refrigerator Operation Manual i.series and Horizon Series

Undercounter Refrigerator Operation Manual i.series and Horizon Series Undercounter Refrigerator Operation Manual i.series and Horizon Series Blood Bank Models i.series: ib105 (Version B) Horizon Series: HB105 (Version B) Laboratory/Pharmacy Models i.series: ilr105 (Version

More information

Warranty Registration

Warranty Registration WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship and materials for a period

More information

OPERATING INSTRUCTIONS FOR LEEC AUTOMATIC CO2 INCUBATORS. MODELS GA2000 and GA2010 MODELS GA3000 and GA3010 With Infrared CO2 detectors CONTENTS

OPERATING INSTRUCTIONS FOR LEEC AUTOMATIC CO2 INCUBATORS. MODELS GA2000 and GA2010 MODELS GA3000 and GA3010 With Infrared CO2 detectors CONTENTS OPERATING INSTRUCTIONS FOR LEEC AUTOMATIC CO2 INCUBATORS MODELS GA2000 and GA2010 MODELS GA3000 and GA3010 With Infrared CO2 detectors CONTENTS 1.0 GENERAL DESCRIPTION 2.0 INSTALLATION AND SETUP 3.0 DESCRIPTION

More information

incubator, the best in its class

incubator, the best in its class 188 188 188 EuroClone incubator, the best in its class More than a new tool: an environment with unique and unmatched features for your cell cultures. ED AN UCED I DESIGNED AND PRODUCED IN ITALY 1 The

More information

MICROCAPSTAR End-Tidal CO 2 Analyzer Instruction Manual

MICROCAPSTAR End-Tidal CO 2 Analyzer Instruction Manual MICROCAPSTAR End-Tidal CO 2 Analyzer Instruction Manual Read instructions carefully before operating this device. ❶ This device is not to be used for Human Life Support applications. ❷ To avoid possible

More information

Techne Dri-Block range. Premium products at affordable prices. Adjustable safety cut-out. 230V and 115V variants. New 5-digit LED display

Techne Dri-Block range. Premium products at affordable prices. Adjustable safety cut-out. 230V and 115V variants. New 5-digit LED display Techne Dri-Block range 2, 3 or 4 block system Twin control unit New countdown timer Adjustable safety cut-out 230V and 115V variants New C and F units Premium products at affordable prices Cool-touch surfaces

More information

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK Analox 1000 Series User Manual Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK T: +44 (0)1642 711400 F: +44 (0)1642 713900 W: www.analox.net E: info@analox.net

More information

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications: Industrial Chilled Mirror Hygrometer Integral frost/dew point measuring head Internal sample pump Optimal Response Injection System ForceFrost TM function Ice-Test user calibration verification User configurable

More information

CO2 INCUBATOR CO2 INCUBATORS

CO2 INCUBATOR CO2 INCUBATORS ( / / ) The incubator is ideal for the experiments of the cultivation of animal cells, sperm/ovum, anaerobic cells, all sorts of microbe cells, hatching/germinating and special tissues. LARGE MEDIUM MINI

More information

BIOMEDICAL REFRIGERATORS

BIOMEDICAL REFRIGERATORS BIOMEDICAL REFRIGERATORS U LT R A L O W F R E E Z E R S - L A B O R AT O R Y, P H A R M A C E U T I C A L A N D M E D I CA L R E F R I G E R AT I O N ARCTIKO CONTROLLER At Arctiko we have the customer

More information

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems A Safe, Stable Environment for Culturing Cells Ultra-reliable Queue water-jacketed CO 2 incubators are carefully engineered to provide an optimal, stable growing environment for cultures. Easy Set-Up Control

More information

Dry Block Heaters. Dry Block Heaters. 2 Block Dry Block Heaters with Lid.

Dry Block Heaters. Dry Block Heaters. 2 Block Dry Block Heaters with Lid. Dry Block Heaters 2 Block Dry Block Heaters with Lid www.ohaus.com 65 Multi-purpose Dry Block Heaters are ideal for applications that require temperature stability. The close tube-to-block contact enables

More information

Model gffoz Process Ozone Sensor (In-Line)

Model gffoz Process Ozone Sensor (In-Line) Date ECO# Rev Description Originator 9/15/97 1.0 First Publication DB 10/8/97 2.0 Miscelaneous corrections DB 10/28/97 3.0 Minor changes BM 5/1/98 3.1 Added CE compliance BM TM IN USA, INCORPORATED 87

More information

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com Model R9900 Indoor Air Quality Meter Instruction Manual reedinstruments com Table of Contents Features... 3 Specifications...3-4 Instrument Description...4-5 Operating Instructions...5-8 Data Hold... 5

More information

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery 99 Washington Street Melrose,

More information

COA-2010-F Electronic CO 2

COA-2010-F Electronic CO 2 COA-2010-F Electronic Analyzer New electronic analyzer specifically designed to monitor and temperature for the verification of in research and pharmaceutical markets. This unit has been developed to incorporate

More information

FROILABO offers a full range of incubators with natural convection, air forced or forced cooling to cover most laboratory applications.

FROILABO offers a full range of incubators with natural convection, air forced or forced cooling to cover most laboratory applications. I N C U B A T O R S INCUBATORS FROILABO offers a full range of incubators with natural convection, air forced or forced cooling to cover most laboratory applications. Component standardization and adaptation

More information

The Professional Choice

The Professional Choice The Professional Choice Product Catalogue Innovation in line with your clinical requirements How do you prepare for situations that leave no room for compromise? How do you get ready for an operation

More information

Reach-In. PLanT GROWTh. Reach-In

Reach-In. PLanT GROWTh. Reach-In E7 Reach-In PLanT GROWTh Reach-In E7 Reach-In PLANT GROWTH Product Overview/Applications Conviron s E7 plant growth chamber is a compact yet highly configurable unit that is suitable for a wide variety

More information

Dual-Mode Infrared Thermometer Instruction Manual

Dual-Mode Infrared Thermometer Instruction Manual 0482 Dual-Mode Infrared Thermometer Instruction Manual 9 1 Introduction Thank you for choosing the Dual-mode Digital Infrared Thermometer, Dual-mode infrared thermometer for short. With the unique technology,

More information

Feature : SEKARGUNA MEDIKA

Feature : SEKARGUNA MEDIKA 1 2 3 Feature : 4 5 6 7 8 CARUM E-Catalog Registered : Ponek & Poned Electric Breastpump : Electric Breastpump : Ardo Medical AG, Switzerland Types of Products : Carum / 63.00.71 AKL Kemenkes RI : 21104411958

More information

VHP ARD BIODECONTAMINATION SYSTEM

VHP ARD BIODECONTAMINATION SYSTEM VHP ARD BIODECONTAMINATION SYSTEM APPLICATION The VHP ARD Biodecontamination System is designed for portable biodecontamination* of clean, dry, sealed Enclosures.** The VHP 1000-ARD Biodecontamination

More information

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification SCC Inc. LMV51 Control Product Description February 7, 2017 The LMV51 is a microprocessor-based burner management system with matching system components for the control and supervision of forced draft

More information

Biomedical Freezer 37 38

Biomedical Freezer 37 38 Biomedical Freezer 37 38 Biomedical C (Upright) C (Upright) This product is design for storage of critical and temperature sensitive biological samples, medical products, and so on in institutions such

More information

portable gas analyser

portable gas analyser www..com portable gas analyser Professional flue gas analyser that combines high quality of sample conditioning with great measurement accuracy. The device is contained in a compact soft casing. Analyser

More information

PATIENT MONITORING SYSTEMS

PATIENT MONITORING SYSTEMS PATIENT MONITORING SYSTEMS PATIENT MONITORING SYSTEMS The benefits of HEYER Scalis to meet the market situation HEYER Scalis function & features make it fit to match the requirement of standard applications

More information

CO2 INCUBATORS. The Safer Choice for Your Laboratory. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A. nuaire.com

CO2 INCUBATORS. The Safer Choice for Your Laboratory. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A. nuaire.com CO2 INCUBATORS The Safer Choice for Your Laboratory NuAire, Inc. 2100 Fernbrook Lane Plymouth, MN 55447 U.S.A. nuaire.com An accessory port is standard on all models providing power to accessories such

More information

Rad-87. Pulse CO-Oximeter OPERATOR S MANUAL

Rad-87. Pulse CO-Oximeter OPERATOR S MANUAL Rad-87 Pulse CO-Oximeter OPERATOR S MANUAL Rad-87 Pulse CO-Oximeter OPERATOR S MANUAL The Rad-87 Operating Instructions provide the necessary information for proper operation of all models of the Rad-87

More information

CA5000 Liquid CO 2 Freezer Backup System

CA5000 Liquid CO 2 Freezer Backup System CA5000 Liquid CO 2 Freezer Backup System OPERATING INSTRUCTIONS MANUAL HAMPSHIRE CONTROLS CORPORATION ONE GROVE STREET / P.O. BOX 516, DOVER, NEW HAMPSHIRE USA 03821 TEL. (603) 749-9424 FAX (603) 749-9433

More information

THERMAX Efficiency Monitor

THERMAX Efficiency Monitor INSTALLATION & OPERATION INSTRUCTIONS THERMAX Efficiency Monitor Oil & Gas Fired Heating Equipment Efficiency Monitoring Instrument Important Safety Instructions Read and safe these instructions before

More information

Servo i. CRC 335 University of South Alabama Cardiorespiratory Care

Servo i. CRC 335 University of South Alabama Cardiorespiratory Care Servo i CRC 335 University of South Alabama Cardiorespiratory Care Servo i Pocket Guide Servo i Initial set up Servo i Discussion Points Power source Internal drive Setting up a new patient Controls Modes

More information

Multi-Parameter Patient Monitor

Multi-Parameter Patient Monitor KIZLON Multi-Parameter Patient Monitor Email: info@kizlonmedical.com Website: www.kizlonmedical.com Multi-Parameter Patient Monitor KPM-A1 Series s of Portable Patient Monitor KPM-A1 Series has color TFT

More information

intuitive intelligent interactive New! Thermo Scientific Heracell 150i and 240i CO 2 Incubators

intuitive intelligent interactive New! Thermo Scientific Heracell 150i and 240i CO 2 Incubators intuitive intelligent interactive New! Thermo Scientific Heracell 150i and 240i CO 2 Incubators Thermo Scientific Heracell 150i and 240i >> Surround your valuable cultures with an environment you can trust.

More information

BlueSpin Magnetic Hotplate Stirrer

BlueSpin Magnetic Hotplate Stirrer BlueSpin Magnetic Hotplate Stirrer BlueSpin LCD Digital 7 Inch Square Magnetic Hotplate Stirrer MS7-H550-Pro 7 inch square hotplate magnetic stirrers are widely used in chemical synthesis, physical and

More information

Airflow Sensors Line Guide

Airflow Sensors Line Guide Line Guide Go with the flow of engineering leadership. All airflow sensors operate on heat transfer flow and differential pressure. But Honeywell Sensing and Control (S&C) offers advanced chip design,

More information

Dry Block Heaters. Dry Block Heaters 2 Block Dry Block Heaters with Lid.

Dry Block Heaters. Dry Block Heaters 2 Block Dry Block Heaters with Lid. Dry Block Heaters Dry Block Heaters 2 Block Dry Block Heaters with Lid sales@novatech-usa.com www.novatech-usa.com Tel: (866) 433-6682 Fax: (866) 433-6684 Tel: (281) 359-8538 Fax: (281) 359-0084 Dry Block

More information

ConchaTherm Neptune Heated Humidifier User s Manual /07 English (EN)

ConchaTherm Neptune Heated Humidifier User s Manual /07 English (EN) 88924-07 06/07 English (EN) ConchaTherm Neptune Heated Humidifier User s Manual REF NO. DESCRIPTION 425-00 ConchaTherm Neptune Heated Humidifier 425-10 ConchaTherm Neptune Heated Humidifier - EMEA 425-20*

More information

Safe Operation Manual. Honeywell IQ Force Gas Detector

Safe Operation Manual. Honeywell IQ Force Gas Detector Safe Operation Manual Honeywell IQ Force Gas Detector Honeywell Analytics 800-663-4164 403-248-9226 Fax 403-575-3708 03JUN2012 P/N 50105843-047 Version 01 http://www.honeywell.com HONEYWELL IQ Force PERSONAL

More information

TOOLS AND INSTRUMENTS

TOOLS AND INSTRUMENTS TOOLS AND INSTRUMENTS MANNIX INSTRUMENTS DELUXE DIGITAL POCKET THERMOMETER DIGITAL ANEMOMETER F/C Switch Protective Cover Auto Power Off ON/OFF Switch Data Hold Simultaneous Display of Air Velocity and

More information

QAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR

QAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR QAS-10000 SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR INSTALLATION, OPERATION AND MAINTENANCE MANUAL QUATROSENSE ENVIRONMENTAL LTD. 5935 OTTAWA STREET, PO BOX 749, RICHMOND, ONTARIO, CANADA. K0A

More information

ABSOLUTE Temperature Control System

ABSOLUTE Temperature Control System Temperature Control System DESCRIPTION The ABSOLUTETM Temperature Control System provides accurate and stable temperature control of liquid source chemicals. Five different models provide temperature control

More information

Atlas Monitor Outline Train the Trainer

Atlas Monitor Outline Train the Trainer Atlas Monitor Outline Train the Trainer A. ATLAS Monitor 1. Atlas Monitor is not designed for use on children younger than 3 years old. 2. Weight: 9.5lbs to 13.2 lbs, depending on configuration 3. Variable

More information

NEW GENERATION. Efficient use of valuable space INCUBATORS

NEW GENERATION. Efficient use of valuable space INCUBATORS NEW GENERATION Efficient use of valuable space INCUBATORS THE NEW HETTCUBE GENERATION Now with touchscreen and more options HettCube 600 600 R HettCube 400 400 R HettCube 200 200 R 2 EVERYTHING UNDER CONTROL

More information

Blood bank refrigerators

Blood bank refrigerators Blood bank refrigerators Cold storage of blood is crucial in light of continuing advancements in medical science. The value of blood and blood bank components coupled with stringent storage requirements

More information

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax TC-324B Manual, Rev. 05.01.31 Single Channel Heater Controller Model TC-324B 1125 Dixwell Avenue, Hamden, CT 06514 (800) 599-4203 / (203) 776-0664 (203) 776-1278 - fax TC-324B Manual, Rev. 05.01.31 TC-324B

More information

REFRIGERATOR M E D I C A L.

REFRIGERATOR M E D I C A L. M E D I C A L REFRIGERATOR NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation. LRM-100 SERIES Labocon Medical Refrigerator LRM-100 Series

More information

portable gas analyser

portable gas analyser www..com portable gas analyser The largest of s analysers equipped with electrochemical cells. It can fit even up to 7 EC cells and up to 3 sensors. GA-60 has a large (320*240), graphical LCD with backlighting.

More information

Advance Blood Storage system from Meditech

Advance Blood Storage system from Meditech Advance Blood Storage system from Meditech Vertical Blood Bank Refrigerator Double Door Vertical Blood Bank Refrigerator Horizontal Blood Bank Refrigerator Solar Blood Bank Refrigerator 1 Advance Blood

More information

LEAKSTOPPER RANGE Multizone water leak detection systems

LEAKSTOPPER RANGE Multizone water leak detection systems LEAKSTOPPER RANGE Multizone water leak detection systems WHAT DOES THE PRODUCT DO? The LeakStopper detects water leaks and instantly triggers an alarm to warn you. It is capable of monitoring between 2

More information

s ter k Hea y Bloc Dr

s ter k Hea y Bloc Dr Advanced Dry Block Heaters Exceptional temperature uniformity and stability Optional external temperature probe Holds interchangeable modular blocks Designed for applications that require repeatable results

More information

HAMILTON-H900. Intelligent humidification for all patient groups

HAMILTON-H900. Intelligent humidification for all patient groups HAMILTON-H900 Intelligent humidification for all patient groups Intelligent Ventilation since 1983 We live for ventilation technology We live for ventilation technology that helps caregivers improve the

More information

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670 Bulletin AV-670 Series 670 Hood Monitor Specifications - Installation and Operating Instructions DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Phone: 219/879-8000 Fax: 219/872-9057

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors

More information

Refrigerated Incubator Model and Operating Instructions

Refrigerated Incubator Model and Operating Instructions Refrigerated Incubator Model 165000 and 165000-2 Operating Instructions N2400379 - Rev. 1 08May2018 1 Contents 1. SAFETY...3 1.1. EMF INTERFERENCE...4 1. PRODUCT INFORMATION...5 1.1 INTRODUCTION...5 2.

More information

P/N: Release Date: January 2012 Copyright EDAN INSTRUMENTS, INC All rights reserved.

P/N: Release Date: January 2012 Copyright EDAN INSTRUMENTS, INC All rights reserved. About this Manual P/N: 01.54.109451-16 Release Date: January 2012 Copyright EDAN INSTRUMENTS, INC. 2008-2012. All rights reserved. Statement This manual will help you understand the operation and maintenance

More information

Operation & Maintenance Manual

Operation & Maintenance Manual Operation & Maintenance Manual for Model 2100 Fire+Smoke systems from Smoke Guard, Inc. 287 N. Maple Grove - Boise, ID 83704 Phone: (800) 574-0330 Fax: (208) 639-7851 E-Mail: info@smokeguard.com Website:

More information