1 WHITE PAPER Gas safety standards are changing in 2020: Will your plant be in compliance? By Jon D. Miller, Technical Compliance Manager Gas detection is usually the first line of defense in plant safety, and hazardous process owners worldwide understand its critical role in risk mitigation. Soon, however, existing equipment and practices for gas detection may no longer suffice. Significant standards changes are coming and the best way to ensure compliance will be to select, specify and install an integrated fire and gas safety system today that will meet the expected 2020 standards. Around the world, manufacturing and processing plants in hazardous industries depend on dedicated fixed gasdetection systems to help them meet the numerous risk-mitigation requirements for combustible and toxic gas detection. Soon, however, owners and operators of these facilities will need to understand and comply with even more rigorous and clearly defined standards and practices related to gas safety systems. New standards expected to be in force by 2020 will impact the selection of gas safety detectors and their control systems for both new installations and retrofits. In hazardous industries, many such projects are currently in the design and specification stages. Individuals responsible for these projects need to be familiar with the new standards so the decisions they make today will conform with tomorrow s requirements. This paper details the specifics of the proposed changes to International Electrotechnical Commission (IEC) standards regarding gas detection and explains what the changes mean for high-hazard process owners. It also discusses other relevant codes and standards (currently in transition) that will impact the selection and installation of gas detection equipment. (See Figure 1.) Lastly, it lists the benefits of integrating gas detection with fire and smoke detection as a comprehensive risk mitigation strategy for plants trying to meet increasingly stringent safety requirements. Harmonizing standards for higher safety and reliability Codes and standards that set product performance criteria and best practice guidelines for industrial plants typically lag behind changes in technology and processes. Since technology and processes outpace prescriptive and safety standards, plants rely on risk assessments to assess safety. Codes and standards are normally modified when risk assessments uncover gaps in the requirements. Today, however, there is an impetus to evolve the codes and standards of regulatory organizations worldwide. In addition to making the codes and standards more relevant for current industrial facilities, those involved wish to set the stage for increased safety and reliability in tomorrow s plants. Another key goal of this effort is to harmonize standards. Currently, each part of the world has industry safety standards that address its specific needs as determined by local regulatory agencies. With many process owners operating in multiple countries or even continents, a single global company might be subject to dozens of different codes and standards. Standards organizations such as the IEC are working toward increased uniformity by cooperating with companies, industries and governments to develop consensus-based standards. According to the IEC website,

2 White Paper Page 2 Description International Australia Canada China European Union Russia United States Combustible Gas Performance IEC AS/NZS C22.2 #152 C JJG 693 GB EN GOST R GOST UL/FM (pending) Open Path / Line-of-Sight Performance IEC AS/NZS C EN GOST R GOST UL/FM Oxygen Performance IEC (pending) AS/NZS 4641 JJG 365 EN GOST ANSI/ISA Toxic Gas Performance IEC (pending) AS/NZS 4641 JJG 9155 EN GOST ANSI/ISA EMC See all above See all above See all above See all above EN See all above See all above Software See all above See all above See all above See all above EN See all above See all above Safety Instrumented System Recommended Practice IEC EN GOST IEC ISA-TR IEC IEC (pending) AS/NZS EN GOST IEC UL/FM Figure 1: This chart outlines general norms (both current and pending) by region, but is not intended to be an inclusive list. The IEC is often used where there are no national standards. the organization also cooperates with international, regional and national partners to produce joint publications, help promote the importance of standardization and to coordinate any potential overlaps in work. IEC updating combustible gas safety standards Activity aimed at modernizing and unifying applicable codes and standards has been particularly notable in the area of gas safety systems. One combustible gas related IEC standard recently released is IEC :2016, Explosive atmospheres Part 29-1: Gas detectors Performance requirements of detectors for flammable gases. This standard specifies general requirements for the construction, testing and performance of fixed gas detectors intended for use in explosive atmospheres such as those found in petrochemical and hydrocarbon processing facilities. The update adds significant new criteria in four areas: 1) Ingress protection requirements The ingress protection rating has taken into account only the enclosure protecting the electronics, not the operation of the sensors inside the enclosure. As products become compliant to this standard, a disclaimer must be placed within the instruction manual stating that the ingress protection rating does NOT imply that the equipment will Figure 2: Ingress protection (IP) testing assesses the protection of detectors against ingress of liquids and/or solid bodies. Under requirements for IEC :2016, the IP rating must either be performance validated, or the manual must clarify operational limitations. Photo courtesy of Det-Tronics.

3 White Paper Page 3 detect gas during and after exposure to such conditions. Otherwise, validation testing should be done by an agency or certifier that can verify the manufacturer s claim. (See Figure 2.) This change will require plant owners and/or product specifiers to pay particular attention to manufacturers ingress protection for gas detectors intended for outdoor use. By choosing detectors with the label marking, plants can be assured that the detectors are rated for the claimed performance. (See Figure 3.) By choosing detectors with the current Edition 2 of the IEC :2016 standard label marking, plants can be assured that the detectors are rated for the claimed environmental conditions. Figure 4: Third-party EMC testing confirms the ability of equipment to function properly regardless of electromagnetic conditions. Photo courtesy of Element. 2) Expanded electromagnetic compatibility testing The IEC :2007 standard requires evaluating detectors for radiated immunity, as well as power supply interruptions, voltage transients and step changes. (See Figure 4.) CL I, DIV 1, GRPS B, C & D (T4) CL I, Zone 1, AEx/Ex db eb IIC T5...T4 In Gb addition to these tests, the IEC :2016 Not included in the revised combustible gas detection CL I, DIV 2, GRPS A,B,C & D (T4) CL I, Zone 1, AEx/Ex db eb [ib] IIC T5...T4 standard Gb requires testing for electrostatic discharge, standard are new WITH test INTRISICALLY requirements SAFE that OUTPUT have FOR been OPTIONAL HART magnetic fields, burst, surge and conducted radiofrequency interference. These changes will align the established by the PORT revision COMMUNICATIONS, committee CONTROL in the DWG draft toxic T4 (Tamb = -55 C to +75 C) T5(Tamb = -55 C to +40 C) gas performance standard. ACIDIC These ATMOSPHERES requirements, EXCLUDED which standard more closely with European electromagnetic will allow detector manufacturers CONDUIT SEAL NOT REQUIRED to verify FOR DIVISION product INSTALLATION CONDUIT SEAL REQUIRED WITHIN 50mm FOR ZONE INSTALLATIONS compatibility (EMC) requirements. performance and provide the relevant information to a product certification agency, may be incorporated into the Once detectors meeting the IEC :2016 next edition of the combustible gas standard. requirements are purchased, plants must take into consideration any manufacturer s special product installation requirements. 1, GRPS B, C & D (T4) CL I, Zone 1, AEx/Ex db eb IIC T5...T4 Gb, GRPS A,B,C & D (T4) CL I, Zone 1, AEx/Ex db eb [ib] IIC T5...T4 Gb WITH INTRISICALLY SAFE OUTPUT FOR OPTIONAL HART CL I, DIV 1, GRPS B, C & D (T4) CL I, Zone 1, AEx/Ex db eb IIC T5...T4 Gb CL I, DIV 2, GRPS A,B,C & D (T4) CL I, Zone 1, AEx/Ex db eb [ib] IIC T5...T4 Gb WITH INTRISICALLY SAFE OUTPUT FOR OPTIONAL HART PORT COMMUNICATIONS, CONTROL DWG T4 (Tamb = -55 C to +75 C) T5(Tamb = -55 C to +40 C) ACIDIC ATMOSPHERES EXCLUDED WARNING: CONDUIT SEAL NOT REQUIRED FOR DIVISION INSTALLATION DO NOT OPEN WHEN AN CONDUIT SEAL REQUIRED WITHIN 50mm FOR ZONE INSTALLATIONS EXPLOSIVE GAS ATMOSPHERE MAY BE PRESENT. PORT COMMUNICATIONS, CONTROL DWG Tamb = -55 C to +75 C) T5(Tamb = -55 C to +40 C) ACIDIC ATMOSPHERES EXCLUDED CONDUIT SEAL NOT REQUIRED FOR DIVISION INSTALLATION ONDUIT SEAL REQUIRED WITHIN 50mm FOR ZONE INSTALLATIONS CL I, DIV 1, GRPS B, C & D (T4) CL I, Zone 1, AEx/Ex db eb IIC T5...T4 Gb CL I, DIV 2, GRPS A,B,C & D (T4) CL I, Zone 1, AEx/Ex db eb [ib] IIC T5...T4 Gb WITH INTRISICALLY SAFE OUTPUT FOR OPTIONAL HART PORT COMMUNICATIONS, CONTROL DWG T4 (Tamb = -55 C to +75 C) T5(Tamb = -55 C to +40 C) ACIDIC ATMOSPHERES EXCLUDED CONDUIT SEAL NOT REQUIRED FOR DIVISION INSTALLATION CONDUIT SEAL REQUIRED WITHIN 50mm FOR ZONE INSTALLATIONS WARNING: DO NOT OPEN WHEN AN EXPLOSIVE GAS ATMOSPHERE MAY BE PRESENT. WARNING: DO NOT OPEN WHEN AN EXPLOSIVE GAS ATMOSPHERE MAY BE PRESENT. EN/IEC IECEx UL X Ex db C T5...T4 OR Ex db [ib] C T5...T4 3) Software function verification Although software requirements are included in the IEC :2007 version of the standard, the IEC :2016 standard includes a test clause for software function verification. This testing will require validation against the requirements, and manufacturers will need to provide evidence of full compliance. One way manufacturers can demonstrate compliance is by using approval agencies such as FM, CSA, UL, DEKRA EXAM GmbH or Sira. (See Resources on page 8.) Detection system controllers that have received agency approval for software functionality will be labeled as meeting the IEC standard. HERE EN/IEC IECEx UL X Ex db C T5...T4 OR Ex db [ib] C T5...T4 EN/IEC IECEx UL X Figure 3: Product labels carry the performance Ex and db extreme C T5...T4 environmental ratings for each corresponding agency so plants OR Ex db can [ib] be C assured T5...T4 that detectors are rated for the claimed environmental conditions. 4) Upper limits system testing The word system here refers to gas detectors in conjunction with their controller. The new standard clarifies requirements for equipment using digital communications during normal gas detection operation. det-tronics.com EN/IEC IECEx UL X Ex db C T5...T4

4 White Paper Page 4 The standard calls for detection systems to be tested under maximum communication transaction rates and activity levels. In addition, the largest and most complex system configuration must be used for testing. These requirements are meant to test necessary safety actions under conditions that simulate the limits of normal gas detection operations. To ensure high reliability of their gas detection systems, plant operators and owners should look for the IEC (or equivalent) label marking on the controllers of systems they are considering for purchase. If a controller lacks such a label, the system does not meet the latest requirements. More standards changes coming Other key gas safety code and standard changes in the works include the following: UL changes for fixed gas detectors The UL STP 9200 committee (chaired by the author of this paper) is working on UL , which is also the second edition of ANSI/ISA , a standard promulgated by the American National Standards Institute and the International Society of Automation. UL uses the requirements for fixed gas detectors in ANSI/ ISA , but it also provides installation and best practice recommendations for the use of gas detection equipment. Included are new recommendations for live equipment maintenance (maintenance done while the equipment is powered up), as well as personnel and property protection, including protection of equipment that would normally be considered unsuitable for a hazardous location. ANSI/ISA provides installation and best practice recommendations for the use of gas detection equipment. In addition, UL offers a broader perspective on the multiple purposes of gas detection equipment. For example, area classification monitoring has been added to align with the Canadian Electrical Code (C22.1). Area classification monitoring is the use of gas detection to verify that the amounts of combustible and toxic gases in different areas of a plant are below the thresholds set for those areas to receive a certain classification. Per Chapter 5 of the National Electrical Code (NEC), National Fire Protection Association (NFPA 70), areas deemed Class I are those where flammable gases, flammable liquid-produced vapors or combustible liquid-produced vapors are or may be present in quantities sufficient to produce explosive or ignitable mixtures. A Class I Division 1 area is one where combustible materials are routinely present in ignitable concentrations. A Class I Division 2 area is one in which the same materials are handled, processed or used, but in which the materials are normally confined and can escape only in the case of accident, breakdown, failure or abnormal operation of ventilation equipment. While the main purpose of gas detection is to increase the safety of personnel and property in hazardous locations, gas detection technology has improved to the point where it can gather information about gas concentrations to help users validate classification for particular areas. CSA Group changes for advanced gas detection Gas detection requirements have recently been clarified in CSA C22.1:2018. In addition, the Canadian Electrical Code now discusses more possible applications for advanced gas detection equipment, including area classification monitoring. Efforts are also ongoing to revise UL , which is referenced within the U.S. NEC, to harmonize with the Canadian Electrical Code. Toxic gas detection Detection of toxic gas leaks in a plant is just as important for safety as combustible gas detection, so plants must take similar risk-mitigating actions to deal with leaks of both types of gas. Two important standards for toxic gas detection are ANSI/ISA and the draft IEC standards. Toxic gas performance standards and combustible gas performance standards are closely aligned, and they are both under continuous improvement. Currently,

5 White Paper Page 5 the IEC Technical Committee 31, Maintenance Team and Joint Working Group 45 committees (also chaired by the author of this paper) are developing new standards for toxic gas detection performance and recommended practices, as well as oxygen detection performance. The IEC toxic gas detection standards are based on European standards, but also take into account current U.S. and Australian requirements. The new IEC toxic gas standard incorporates many of the new concepts already mentioned in relation to the updated IEC combustible gas detection standard (see the above discussion of ingress protection, EMC, software requirements and system requirements). In addition, the toxic gas performance standard uniquely defines Type HM (Health Monitoring) and Type SM (Safety Monitoring) devices in order to segregate requirements and acceptance criteria for these two different uses of toxic gas detection equipment. The two terms can be defined as follows: Type HM: a detection device designed to protect an individual for example, a portable gas detector that is either carried or worn by a person in a hazardous area. If the gas detector goes into alarm, the person carrying or wearing it must leave the area immediately. Type SM: a detection device designed to protect people in general rather than a particular individual. Safety monitoring is done by fixed gas detectors installed in areas where hazardous gas leaks may occur. (See Figure 5.) When gas detection isn t enough integrating fire & gas safety While combustible and toxic gas detection is the first line of defense in mitigating threats to personnel, equipment and processes, gas detection equipment cannot detect the potential consequences of a gas leak for example, a fire or explosion that occurs when leaking gas comes into contact with an ignition source. Detection of such events is left to fire and/or smoke detection equipment. Since many gas detection control panels are not scalable, i.e., they are unable to handle inputs from additional detectors and are not certified to connect to fire or smoke detection systems or gas systems, plants may opt to install separate, unrelated equipment for detecting fire and smoke. Or, they may forgo fire and smoke detection altogether, despite code and standard requirements, putting their facilities and personnel at risk. A safer and highly capable option available today is a complete fire and gas (F&G) safety system designed to warn of and contain or mitigate events that may be a threat to personnel or process operations. Based on digital technology, an advanced F&G safety system is an integrated and scalable set of inputs and outputs consisting of flame, gas and smoke detectors, as well as alarm signaling, notification and extinguishing agent release and/or deluge equipment. (See Figure 6.) A safer and highly capable option available today is a complete fire and gas (F&G) safety system designed to warn of and contain or mitigate events that may be a threat to personnel or process operations. Figure 5: The Det-Tronics GT3000 toxic gas detector is an example of a Type SM detector, one of two toxic gas detector categories newly defined by IEC to segregate requirements based on the two different uses of toxic gas detectors protecting individuals versus protecting people in general (by using Safety Monitoring devices). Distinct from a process control system (PCS), which manages conditions in a plant s process system, an F&G safety system continually monitors and analyzes data collected by detectors in the process area(s) and takes appropriate safety-related actions when necessary. An effective F&G safety system should be able to inform the PCS of detection device status in defined process areas so that the process owner knows exactly what, where

6 White Paper Page 6 and when hazardous events are occurring. Since the F&G safety system and the PCS are independent, however, failure of the PCS should not affect the operation of the F&G safety system. In traditional F&G safety systems, each detector is directly hardwired to the controller using analog or contact closures in a conventional (i.e., point-to-point) design. While this configuration provides enhanced alarm and fault information to the controller, specific details of the event do not reach the controller because of the simple, binary nature of the communication path. By contrast, in a state-of-the-art addressable loop F&G safety system, the detectors and other devices are configured in a bi-directional loop topology, which substantially increases configuration flexibility and the amount of diagnostic information that can be shared with the controller. The addressable loop configuration is also more reliable and survivable than traditional configurations, because the controller constantly communicates with each device in the loop in order to receive the latest alarm and diagnostic information. Fires and gas leaks are relatively rare occurrences compared to trouble conditions involving equipment in an F&G system (which may stem from the fact that the equipment has not been properly maintained). Oldstyle F&G systems with relay contacts can alert users to equipment problems, but often leave them guessing FIRE AND GAS SAFETY SYSTEM Toxic gas detector Flame detector Acoustic gas detector Input/output module XP smoke detector Combustible gas detector Manual call Beacon Input/output module Fire & gas safety system controller Line-of-sight IR gas detector Fire water pumps Automatic deluge valves Mitigation Process control system (PCS) Plant emergency shutdown system (ESD) Figure 6: An effective F&G safety system may include multiple types of detection devices plus a fire & gas safety system controller with inputs and outputs for notification and suppression-activation devices. An addressable loop design assures the highest system reliability. (Diagram courtesy of Det-Tronics.)

7 White Paper Page 7 about the exact nature of the problem. Advanced F&G systems, however, can provide additional information about a trouble condition, making it easy to solve the problem. For example, the system might inform a user that a certain detector can no longer see because of a dirty window, so the user knows that the window needs to be cleaned. State-of-the-art integrated F&G systems also offer redundancy and fault tolerance for increased reliability and availability. If the primary power supply shortcircuits or power is interrupted, a battery backup system kicks in to keep the system operating. And, if its local area network (LAN) communications loop is cut at any point, the system remains fully functional, with every device still able to signal an alarm. (See Figure 7.) Applicable documents for integrated F&G systems include NFPA 72 and ISA-TR and other global standards. NFPA 72 is the National Fire Alarm and Signaling Code, which covers initiating devices such as fire detectors. Gas detectors were added as initiating devices in Advanced F&G systems are fully compliant with NFPA 72 because of their power supply redundancy, and also their communication fault tolerance, which assures the signal integrity required by the standard. Issued by the ISA 84 standards panel, ISA-TR is a technical report that defines the lifecycle and technical requirements for ensuring effective design of fire and gas detection systems for process industries. State-of-the-art integrated F&G systems offer redundancy and fault tolerance for increased reliability and availability. The performance metrics (for rating a fire and gas system s effectiveness) established in the report include availability, which, as already mentioned, is increased by the redundancy and fault tolerance of advanced F&G systems. Controller requirements for an integrated F&G safety system The brain of an F&G safety system is a safety controller that is integrated with, but independent of, the PCS. In addition to being secure, the controller should be scalable and flexible enough to integrate fire and gas systems into a single loop. In addition to handling inputs and outputs, the controller should be able to provide real-time F&G system status and troubleshoot the system. It should also facilitate easy programming and configuration of flame and gas detectors and other field devices. Finally, it should be certified by an accredited third-party certifier in accordance with NFPA 72 for flame and gas detection, which means it is able to: Detect specialized hazardous events (gases or vapors, fires, etc.) Minimize responses to false events Provide automatic and/or manual mitigation of detected hazardous events Annunciate events to personnel Provide information on system readiness/health Figure 7: State-of-the-art F&G safety systems depend on a faulttolerant safety controller such as the Eagle Quantum Premier (EQP) controller from Det-Tronics (shown). The EQP can incorporate smoke detection technologies for high-risk applications into a single integrated safety system that simplifies installation and provides comprehensive indication and notification of device-specific alarms, troubles, faults and diagnostics. Provide historical information, including calibration, alarm and fault logs Communicate with third-party systems such as the PCS and ESD

8 White Paper Page 8 Conclusion New and tougher combustible and toxic gas detection performance standards are being introduced for manufacturing and processing plants in hazardous industries. In their efforts to comply with these new standards, facility owners and operators may discover that the most effective approach is to abandon traditional detection technology in favor of state-of-the-art F&G safety systems. Rather than using a patchwork of disparate devices and equipment, advanced F&G safety setups offer integrated systems capable of detecting flame, smoke and gas. When necessary, F&G safety systems sound alarms and take other actions to mitigate the consequences of dangerous events such as fires or toxic gas leaks. Though they operate independently of a PCS to ensure continuous operation, F&G safety systems can be integrated with the PCS to communicate about events that may be threatening to personnel or process operations. In addition, some currently available advanced F&G safety systems are scalable, fault tolerant and easily configurable. They also provide users with real-time system status and diagnostic information. Though they may cost more than older systems, these state-of-the-art F&G safety systems enable plants to fully integrate fire and gas safety for maximum safety system reliability and availability. About the author Jon D. Miller has over 25 years experience in functional safety and hazardous locations, focusing on fire and gas detection and systems with Det-Tronics since 1996, and is currently the company s Technical Compliance Manager. He is Chairman for the U.S. and International Gas Detection Standards Development Committees and is a member of IEEE, ISA, UL, and IEC committees responsible for hazardous locations and functional safety electrical equipment. Miller holds an MBA, a bachelor s degree in Electrical Engineering and currently serves as: Convener of IEC TC31 MT (Combustible Gas Performance) Convener of IEC TC31 JWG45 (Toxic Gas Performance) IECEx USNC voting member (Hazardous Locations) Chairman of UL STP9200 TG60079 (Combustible Gas Performance) Chairman of UL STP9200 TG62990 (Toxic Gas Performance) About Det-Tronics Det-Tronics is a global leader in fire and gas safety systems, providing flame and gas detection and hazard mitigation systems for high-risk processes and industrial operations. The company designs, manufactures and commissions certified SIL 2-capable flame and gas safety products, including the X3301 Multispectrum Infrared Flame Detector and the Eagle Quantum Premier (EQP) Fire and Gas Safety Controller. Resources 1. International Electrotechnical Commission (IEC) 2. FM Approvals (FM) 3. CSA Group (CSA) 4. UL Standards (UL) 5. American National Standards Institute (ANSI) 6. International Society of Automation (ISA) 7. DEKRA EXAM GmbH 8. Sira Certification Service (SCS) 9. DNV GL NFPA 70 : National Electrical Code NFPA 72 : National Fire Alarm and Signaling Code NFPA 70, NFPA 72, National Electrical Code and NEC are registered trademarks of the National Fire Protection Association, Quincy, Mass Corporate Office 6901 West 110th Street Minneapolis, MN USA det-tronics.com Phone: Toll-free: Fax: det-tronics@det-tronics.com 2019 Detector Electronics Corporation. All rights reserved.

Gas safety standards are changing in 2020:

Gas safety standards are changing in 2020: WHITE PAPER Gas safety standards are changing in 2020: Will your plant be in compliance? By Jon D. Miller, Technical Compliance Manager Gas detection is usually the first line of defense in plant safety,

More information

Integrating Fire and Gas Safety with Process Control Systems:

Integrating Fire and Gas Safety with Process Control Systems: WHITE PAPER Integrating Fire and Gas Safety with Process Control Systems: Why, What and How If a fire, smoke or gas leak is detected in an industrial facility, prescriptive actions must be taken by the

More information

Smoke detection in hazardous areas:

Smoke detection in hazardous areas: WHITE PAPER Smoke detection in hazardous areas: What you need to know Smoke detection in hazardous areas requires detectors that operate effectively and safely in explosive environments. Having the correct

More information

Case Study. INTEGRATING Fire & GAS SAFETY WITH PROCESS CONTROL SYSTEMS

Case Study. INTEGRATING Fire & GAS SAFETY WITH PROCESS CONTROL SYSTEMS INTEGRATING Fire & GAS SAFETY WITH PROCESS CONTROL SYSTEMS INTEGRATING Fire & GAS SAFETY WITH PROCESS CONTROL SYSTEMS If a fire, smoke or gas leak is detected in an industrial facility, prescriptive actions

More information

Fire and gas safety systems:

Fire and gas safety systems: 26 Functional safety Fire and gas safety systems: Conquering the complexities of functional safety products and systems certifications Owners and operators of hazardous processes need their fire and gas

More information

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance Combustible and Toxic Gas Detection Solutions Performance and Safety Beyond Compliance Reliable Solutions from Det-Tronics, Your Partner in Safety Trusted Response with the Utmost Confidence Our proven

More information

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance Combustible and Toxic Gas Detection Solutions Performance and Safety Beyond Compliance Reliable Solutions from Det-Tronics, Your Partner in Safety Trusted Response with the Utmost Confidence Our proven

More information

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY Agenda 1 Challenges in the Process Industry International codes and standards F&G in an industrial Facility Honeywell s industrial F&G

More information

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions The Most Versatile Flame Detectors in the World Optical Flame Detection Solutions The Global Leader in Flame Detection Superior Performance and Reliability Flame detection is the very essence of the proud

More information

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors SAFETY MANUAL X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors SAFETY-CERTIFIED Flame DETECTORs This manual addresses the specific requirements and recommendations applicable to the proper

More information

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions The Most Versatile Flame Detectors in the World Optical Flame Detection Solutions The Global Leader in Flame Detection Superior Performance and Reliability Flame detection is the very essence of the proud

More information

IEC TC31 (Explosive Atmospheres) Gas Detection as Method of Protection Jon Miller

IEC TC31 (Explosive Atmospheres) Gas Detection as Method of Protection Jon Miller IEC TC31 (Explosive Atmospheres) Gas Detection as Method of Protection Jon Miller Electronics Corporation Approvals Engineering Manager Convener of IEC TC31 MT60079-29 (Gas Performance) IECEx USNC voting

More information

Instructions. Explosion Proof Smoke Detector U Rev: 9/

Instructions. Explosion Proof Smoke Detector U Rev: 9/ Instructions Explosion Proof Smoke Detector U0. Rev: 9/ 9-7 Table of Contents OVERVIEW... FEATURES... BENEFITS... SPECIFICATIONS... OPERATION... Warm Up... Outputs... Integral Wiring Compartment... LED...

More information

Meeting NFPA standards for

Meeting NFPA standards for 24 Fire safety Meeting NFPA standards for flame, smoke and gas detection Fire is one of the most critical hazards in any built environment, and industrial processes and facilities that involve volatile

More information

Some types of gas detectors

Some types of gas detectors ELECTRONICALLY REPRINTED FROM SEPTEMBER 2018 Gas Detection as a Risk Mitigation Technique There are many differences between gas detection systems used for process monitoring and those used for protecting

More information

Selecting fire and gas detectors for extreme environments:

Selecting fire and gas detectors for extreme environments: WHITE PAPER Selecting fire and gas detectors for extreme environments: Functional safety in harsh and remote locations Liquid natural gas (LNG) facilities in the Russian Arctic. Drilling platforms in the

More information

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL SAFETY MANUAL PointWatch Eclipse Infrared Hydrocarbon Gas Detector SIL 2 Certified Model PIRECL Safety Certified Model PIRECL PointWatch Eclipse IR Gas Detector This manual addresses the specific requirements

More information

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

SAFETY MANUAL. Multispectrum IR Flame Detector X3301 SAFETY MANUAL Multispectrum IR Flame Detector X3301 SAFETY-CERTIFIED MODEL X3301 MULTISPECTRUM INFRARED DETECTOR This manual addresses the specific requirements and recommendations applicable to the proper

More information

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY World-class services help reduce incidents, protect the environment, and keep people and plants safe White Paper PAGE 1 Introduction

More information

Fire protection in hazardous locations:

Fire protection in hazardous locations: WHITE PAPER Fire protection in hazardous locations: Meeting NFPA standards for flame, smoke and gas detection Fire is one of the most critical hazards in any built environment, and industrial processes

More information

SAFETY MANUAL. Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS)

SAFETY MANUAL. Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS) SAFETY MANUAL Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS) Sensor Module (GTS) Transmitter (GTX) Detector (GT3000) SAFETY CERTIFIED GT3000

More information

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY World-class services help reduce incidents, protect the environment, and keep people and plants safe White Paper PAGE 1 Introduction

More information

Selecting fire and gas detectors for harsh and remote locations

Selecting fire and gas detectors for harsh and remote locations Selecting fire and gas detectors for harsh and remote locations Liquid natural gas (LNG) facilities in the frozen Russian Arctic. Drilling platforms in the swells of the North Sea. Pipelines that cross

More information

Instructions. Det-Tronics SmokeWatch Explosion Proof Smoke Detector U Rev: 3/

Instructions. Det-Tronics SmokeWatch Explosion Proof Smoke Detector U Rev: 3/ Instructions Det-Tronics SmokeWatch Explosion Proof Smoke Detector U5015 Rev: 3/17 95-8723 Table of Contents OVERVIEW...1 FEATURES...1 BENEFITS...1 SPECIFICATIONS...2 OPERATION...3 Warm Up...3 Outputs...3

More information

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES DET-TRONICS SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION Eagle Quantum Premier is a configurable, distributed, intelligent safety system providing flame

More information

INSTRUCTIONS. Eagle Quantum Premier (EQP) Addressable Smoke & Heat (ASH) Module EQ3750ASH. 5.1 Rev: 4/

INSTRUCTIONS. Eagle Quantum Premier (EQP) Addressable Smoke & Heat (ASH) Module EQ3750ASH. 5.1 Rev: 4/ INSTRUCTIONS Eagle Quantum Premier (EQP) Addressable Smoke & Heat (ASH) Module EQ3750ASH 5.1 Rev: 4/17 INSTRUCTIONS Eagle Quantum Premier (EQP) Addressable Smoke & Heat (ASH) Module EQ3750ASH DESCRIPTION

More information

Selecting fire and gas detectors for extreme environments

Selecting fire and gas detectors for extreme environments Fire & gas detection 21 Selecting fire and gas detectors for extreme environments Liquid natural gas (LNG) facilities in the frozen Russian Arctic. Drilling platforms in the swells of the North Sea. Pipelines

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60079-29-2 Edition 2.0 2015-03 Explosive atmospheres Part 29-2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen INTERNATIONAL

More information

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview Overview Modern combustion (or gas) turbine packages typically include an axial compressor, a combustion section and a turbine. Both compressor and turbine sections consist of one or more sets of fixed

More information

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals Selecting a Safe Tank Gauging Product Understanding Hazardous Area Definitions for Equipment Approvals Hazardous Area Approvals A Worldwide Requirement There are many environmental considerations within

More information

Why AC800M High Integrity is used in Burner Management System Applications?

Why AC800M High Integrity is used in Burner Management System Applications? Why AC800M High Integrity is used in Burner Management System Applications? Prepared by: Luis Duran Product Marketing Manager Safety Systems ABB Process Automation/Control Technologies TÜV Functional Safety

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The

More information

Safe Operation Manual. Honeywell IQ Force Gas Detector

Safe Operation Manual. Honeywell IQ Force Gas Detector Safe Operation Manual Honeywell IQ Force Gas Detector Honeywell Analytics 800-663-4164 403-248-9226 Fax 403-575-3708 03JUN2012 P/N 50105843-047 Version 01 http://www.honeywell.com HONEYWELL IQ Force PERSONAL

More information

New requirements for IEC best practice compliance

New requirements for IEC best practice compliance New requirements for IEC 61511 best practice compliance Proof testing and a SIL study may no longer be enough by Sven Grone Schneider Electric Safety Services Practice Leader Executive summary Since its

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

Dependable Solutions for Gas Detection

Dependable Solutions for Gas Detection Dependable Solutions for Gas Detection Combustibles/Flammables Standard & Exotic Toxics Oxygen Enrichment/Deficiency Introduction to Sensidyne Established in 1983 - acquired by Schauenburg GmbH in April

More information

Case Study. Selecting fire and gas detectors for harsh and remote locations. INSTRUMENTATION

Case Study. Selecting fire and gas detectors for harsh and remote locations.  INSTRUMENTATION Selecting fire and gas detectors for harsh and remote locations Liquid natural gas (LNG) facilities in Y the frozen Russian Arctic. Drilling platforms in the swells of the North Sea. Pipelines that cross

More information

Instructions Dual Spectrum Infrared Flame Detector PM-5MPX. 4.1 Rev: 8/

Instructions Dual Spectrum Infrared Flame Detector PM-5MPX. 4.1 Rev: 8/ Instructions 95-8562 Dual Spectrum Infrared Flame Detector Rev: 8/13 95-8562 Table of Contents Application... 1 Detector use in hazardous areas... 2 Electrical Characteristics.... 2 Environmental Characteristics...

More information

Intrinsically Safe or Explosionproof? Understanding the technology

Intrinsically Safe or Explosionproof? Understanding the technology SUMMARY Intrinsically Safe or Explosionproof? Understanding the technology The phrase Intrinsically Safe is often used generically to describe products destined for hazardous (explosive) areas. This paper

More information

AS/NZS :2008

AS/NZS :2008 AS/NZS 60079.29.2:2008 Australian/New Zealand Standard Explosive atmospheres Part 29.2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen AS/NZS 60079.29.2:2008

More information

F&G detection system for LNG plants

F&G detection system for LNG plants LNG PLANT F&G detection system for LNG plants The historical safety record for the LNG industry is strong. Engineering, installation and lifetime use takes into account the well known hazards of such an

More information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

Safety Instrumented Fire & Gas Systems

Safety Instrumented Fire & Gas Systems Safety Instrumented Fire & Gas Systems aesolutions Provides Full-Service Fire & Gas Engineering and Products The aesolutions FM-approved family of Fire & Gas safety systems ensures compliance with the

More information

For Complete Fire and Gas Solutions

For Complete Fire and Gas Solutions Industrial Fire For Complete Fire and Gas Solutions 2 The Total Package What do you need from an integrated fire and gas system? In industrial fire and gas environments it s important to have a reliable

More information

Instructions Det-Tronics Standard Gas Panel. 1.1 Rev: 10/

Instructions Det-Tronics Standard Gas Panel. 1.1 Rev: 10/ Instructions Det-Tronics Standard Gas Panel. Rev: 0/ Table Of Contents Description... Features AND BENEFITS.... Enclosure... SYSTEM COMPONENTS.... 3 Field Devices... 3 IMPORTANT SAFETY NOTES.... 4 Installation....

More information

FUNCTIONAL SAFETY MANUAL

FUNCTIONAL SAFETY MANUAL FUNCTIONAL SAFETY MANUAL UltraSonic EX-5 Ultrasonic Gas Leak Detector The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent

More information

Explosive atmospheres Part 29-2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen

Explosive atmospheres Part 29-2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen IEC 60079-29-2 Edition 2.0 2015-03 REDLINE VERSION colour inside Explosive atmospheres Part 29-2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen

More information

Incus Ultrasonic Gas Leak Detector Wide Area Coverage for Pressurized Gas Leaks

Incus Ultrasonic Gas Leak Detector Wide Area Coverage for Pressurized Gas Leaks FGD-PDS-Incus-Ultrasonic-Gas-Leak-Detector Product Data Sheet February 2015 Wide Area Coverage for Pressurized Gas Leaks The Incus is an advanced gas leak detector that uses four sensitive acoustic sensors

More information

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors SAFETY MANUAL FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent

More information

Fire and Gas Detection and Mitigation Systems

Fire and Gas Detection and Mitigation Systems Fire and Gas Detection and Mitigation Systems Dr. Lawrence Beckman, PE, TÜV FSExp SafePlex Systems, Inc., Houston, Texas ABSTRACT Fire and Gas Detection systems are key components in the overall safety

More information

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS A Worldwide Manufacturer of Process Analyzers and Instrumentation RELIABILITY EXPERIENCE SOLUTIONS AMETEK Process Instruments is a worldwide

More information

Dräger Flame 2100 Flame Detection

Dräger Flame 2100 Flame Detection Dräger Flame 2100 Flame Detection Working in areas with combustible gases, vapors, or materials requires fire/ flame detection as a life-saving necessity. The best solutions must combine state-of-the-art

More information

EtherCAT Box Modules (EPxxxx-xxxx)

EtherCAT Box Modules (EPxxxx-xxxx) Notes about operation of EtherCAT Box Modules (EPxxxx-xxxx) in potentially explosive areas (ATEX) Version: 1.1.0 Date: 2011-06-10 Table of Contents Table of Contents 1 Foreword 1 1.1 Notes on the documentation

More information

SAFETY MANAGER SC Ensure safety, simplify operations and reduce lifecycle costs

SAFETY MANAGER SC Ensure safety, simplify operations and reduce lifecycle costs SAFETY MANAGER SC Ensure safety, simplify operations and reduce lifecycle costs Meet Today s Cost and Complexity Challenges Industrial process plants are trying to reduce their process control and safety

More information

Certification Supplement Manual

Certification Supplement Manual PROCESS ANALYSERS SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 2 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EC DECLARATION OF CONFORMITY

More information

2015 Honeywell Users Group Europe, Middle East and Africa

2015 Honeywell Users Group Europe, Middle East and Africa 2015 Honeywell Users Group Europe, Middle East and Africa Safety System Lifecycle Support and Honeywell s capabilities in Industrial Fire & Gas Johan School, Honeywell (Product Manager Safety Systems)

More information

Dräger Flame 2500 Flame Detection

Dräger Flame 2500 Flame Detection Dräger Flame 2500 Flame Detection Working in areas with combustible gases, vapours or materials requires fire/ flame detection as a life-saving necessity. The best solutions must combine state-of-the-art

More information

Certification Supplement Manual

Certification Supplement Manual SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 5 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EU DECLARATION OF CONFORMITY 3 EUROPEAN

More information

Medical devices and electromagnetic compatibility. Addressing the requirements of IEC , 4 th Edition

Medical devices and electromagnetic compatibility. Addressing the requirements of IEC , 4 th Edition Medical devices and electromagnetic compatibility Addressing the requirements of IEC 60601-1-2, 4 th Edition Executive Summary Risk of electromagnetic interference and immunity have long been important

More information

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Polytron 8200 CAT Detection of flammable gases and vapors Dräger Polytron 8200 CAT Detection of flammable gases and vapors The Dräger Polytron 8200 CAT is an advanced explosion proof transmitter for the detection of flammable gases in the lower explosion limit

More information

Flame Detection Jon Sarfas

Flame Detection Jon Sarfas Flame Detection Jon Sarfas Agenda Introduction Detection Principles FL4000H MSIR Flame Detector Flame Test Lamp Installation Best Practice Features & Benefits Applications Introduction Primary objectives:

More information

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION DET-TRONICS SPECIFICATION DATA Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION The EQ2200UVHT UV Flame Detector is used with the Eagle Quantum

More information

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

Process Control PIP PCEA001 Fixed Gas Detection Guidelines November 2015 Process Control PIP PCEA001 PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice has been prepared from the technical

More information

Annubar Flowmeter Series

Annubar Flowmeter Series Reference Manual Appendix B Approvals Annubar Flowmeter Series Hazardous Locations Installations.................. page B-1 Rosemount 3051SFA Product Certifications.......... page B-1 Rosemount 3095MFA

More information

Overview of Standards for CO Detection Products

Overview of Standards for CO Detection Products Overview of Standards for CO Detection Products Rev 1.1 1 General Overview... 3 2 Application and Installation Codes & Standards... 3 3 Product Standards... 4 4 Certified and Listed Products (Conforms

More information

Annex to: IECEx ULD U Issue. No. 2 Manufacturer: Detector Electronics Corporation Electrical apparatus: Eagle Quantum Premier system Modules

Annex to: IECEx ULD U Issue. No. 2 Manufacturer: Detector Electronics Corporation Electrical apparatus: Eagle Quantum Premier system Modules Description of EQ3XXXabcd (Controller): The Controller, Model EQ3XXX, performs all communication, command and control functions for the Eagle Quantum Premier System. The Controller supports both static

More information

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector FUNCTIONAL SAFETY MANUAL Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector The information and technical data disclosed in this document may be used and disseminated only for the purposes

More information

Is your current safety system compliant to today's safety standard?

Is your current safety system compliant to today's safety standard? Is your current safety system compliant to today's safety standard? Abstract It is estimated that about 66% of the Programmable Electronic Systems (PES) running in the process industry were installed before

More information

Beamex. Calibration White Paper. Calibration in hazardous areas

Beamex. Calibration White Paper.   Calibration in hazardous areas Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous

More information

G-TECTA TM. Portable Gas Detection Instruments

G-TECTA TM. Portable Gas Detection Instruments G-TECTA TM Portable Gas Detection Instruments 2 Why Linde gas detection? The Linde Group is a global leader in the supply of gases, we provide expertise and product solutions to industry, commerce, science

More information

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System SAFETY MANUAL Open Path Hydrocarbon Gas Monitoring System The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically

More information

GAS DETECTORS. When every second counts

GAS DETECTORS. When every second counts GAS DETECTORS When every second counts PERFORMANCE AND SAFETY BEYOND COMPLIANCE We deliver rock-solid, performance-tested detectors for a wide variety of gas hazards, all with global approval. Our proven

More information

Dräger PIR 7200 Toxic Gas Detection Transmitter

Dräger PIR 7200 Toxic Gas Detection Transmitter Dräger PIR 7200 Toxic Gas Detection Transmitter ST-11660-2007 When you are looking for a carbon dioxide monitor you can trust, consider the Drager PIR 7200. This explosion-proof point gas detection transmitter

More information

Autronica Fire and Security AS ID:

Autronica Fire and Security AS ID: 1 1 Autronica Fire and Security AS A leading innovator, manufacturer and supplier of fire & gas detection equipment Founded in 1957 in Trondheim, Norway Protecting life, environment and property 2 Fire

More information

Beamex Calibration White Paper. Calibration in hazardous areas

Beamex Calibration White Paper.  Calibration in hazardous areas Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following

More information

FUNCTIONAL SAFETY MANUAL

FUNCTIONAL SAFETY MANUAL f u n c t i o n a l S a f e t y M a n u a l FUNCTIONAL SAFETY MANUAL Gassonic Surveyor and Gassonic Observer Ultrasonic Gas Leak Detectors The information and technical data disclosed in this document

More information

Guide to Intrinsically Safe Portable Radios

Guide to Intrinsically Safe Portable Radios Guide to Intrinsically Safe Portable Radios An overview of common IS standards www.taitradio.com GUIDE TO INTRINSICALLY SAFE PORTABLE RADIOS SUMMARY The development of equipment for explosive atmospheres

More information

Setting the Standard in Third-party Certification

Setting the Standard in Third-party Certification Setting the Standard in Third-party Certification 1 Benefits enjoyed by FM Approvals customers FM Approvals can help you: Meet client demands Fulfill jurisdictional requirements Differentiate your product

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION IEC TS 62603-1 Edition 1.0 2014-05 colour inside Industrial process control systems Guideline for evaluating process control systems Part 1: Specifications INTERNATIONAL ELECTROTECHNICAL

More information

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas Intrinsic Safety Intrinsically Safe Solutions Accurate Weighing in Hazardous Areas Accidents in hazardous areas can have dramatic consequences for businesses in terms of both human life and profit. Intrinsically

More information

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance

More information

Technical Paper. Functional Safety Update IEC Edition 2 Standards Update

Technical Paper. Functional Safety Update IEC Edition 2 Standards Update Technical Paper Functional Safety Update IEC 61511 Edition 2 Standards Update Functional Safety Update Table of Contents 1.0 Introduction 2.0 IEC 61511-1 changes 3.0 IEC 61511-2 changes 4.0 IEC 61511-3

More information

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories Hazardous Locations: Understanding the Basics of Global Compliance Requirements Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories DISCLAIMER/ TERMS OF USE: THE INFORMATION

More information

Guide to Hazardous Location Approvals:

Guide to Hazardous Location Approvals: Selection Guide Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches Introduction There are many considerations when selecting a switch to be used in hazardous areas. In addition

More information

August Process Industry Practices Electrical. PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification

August Process Industry Practices Electrical. PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification Electrical Engineering Guide for Determining Electrical Area Classification PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice

More information

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches A Selection Guide Introduction There are many considerations when selecting a switch to be used in hazardous areas. In

More information

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions Because every life has a purpose PrimaX IR Gas Transmitter Every feature of the SIL 2 engineered PrimaX IR Gas Transmitter

More information

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY >OLYL >H]LSLUN[O 4H[[LYZ SMOKELESS FLARE MONITOR Smokeless Flare Monitor (FM) Smokeless flares incinerate flammable hazardous

More information

LifeCycle Engineering & Field Services

LifeCycle Engineering & Field Services Process & Analytical Solutions LifeCycle Engineering & Field Services SafeGuarding Products & Systems Lead with Integrity and Success Follows Proudly serving and supporting western Canadian Industry for

More information

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 8310 IR Detection of flammable gases and vapour Dräger Polytron 8310 IR Detection of flammable gases and vapour The Dräger Polytron 8310 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

Session Four Functional safety: the next edition of IEC Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd

Session Four Functional safety: the next edition of IEC Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd Abstract Session Four Functional safety: the next edition of IEC 61511 Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd The functional safety standard IEC 61511 provides a framework for managing

More information

IEC61511 Standard Overview

IEC61511 Standard Overview IEC61511 Standard Overview Andre Kneisel Instrumentation Engineer Chevron C.T. Refinery SAFA Symposium 2011 August 5 th, 2011 Presentation Overview Provide some understanding of the key aspects of Functional

More information

Guide to Explosion Protection and Plant Safety

Guide to Explosion Protection and Plant Safety Guide to Explosion Protection and Plant Safety Explosion Protection and Plant Safety In almost every industrial application flammable substances are used. Equipment installed in these areas needs to be

More information

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance IR4000 Point Infrared Combustible Gas Detection System The Reliable and Flexible Safety Solution That s Low Maintenance Multi-Point Gas Detection That s Fast Set-Up, Low Maintenance, Cost-Effective The

More information

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours Dräger Polytron Pulsar 2 Detection of flammable gases and vapours The Dräger Polytron Pulsar 2 is the latest infrared technology in open path gas detection. Equipped with all the same functions as the standard

More information

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions!

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions! Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions! www.spectrex.net 2 SafEye Quasar 900 Series Open Path Gas Detector The

More information

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas Page 1 of 5 Title Install fixed gas detection apparatus in hazardous areas Level 4 Credits 2 Purpose This unit standard covers the installation, calibration, and response checking of fixed gas detection

More information

GasAlertMicroClip X3 Specifications

GasAlertMicroClip X3 Specifications GasAlertMicroClip X3 Specifications The instrument must satisfy the following: Physical Specifications Size (h x w x d) Physical size shall be no larger than 4.4 x 2.4 x 1.2 in. / 11.3 x 6.0 x 3.2 cm Weight

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Certificate: 2385571 Project 2447891 Issued to: Mine Safety Appliances 1000 Cranberry Woods Drive Cranberry Township, PA 16066 USA Issued by: Jocelyn Jens Product Group

More information