Speedlock AMC Connectors...KA1. Armored Cable Connectors...KB1-KB5 Metal Clad Cable Connectors...KB1-KB5 Flexible Metal Conduit Connectors...
|
|
- Madeleine Walker
- 5 years ago
- Views:
Transcription
1 SECTION K INDEX Product Description Page Number Speedlock AMC Connectors KA Armored Cable Connectors KB-KB5 Metal Clad Cable Connectors KB-KB5 Flexible Metal Conduit Connectors KB-KB5 45 Armored Cable Connectors KB2 45 Flexible Metal Conduit Connectors KB2 0 Armored Cable Connectors KB 0 Flexible Metal Conduit Connectors KB Aluminum Sheathed Cable Connectors KB6 Non Metallic Sheathed Cable Connectors KB-KB8 0 N. Frontage Road Skokie, Illinois 600
2 Notes 0 N. Frontage Road Skokie, Illinois 600
3 KA Speedlock Steel Box Connectors Type AMC To ground and secure MC, AC, and Flexible Metal Conduit to boxes and enclosures. ETP Speedlock Steel Box Connectors KA No locknut required. Single-unit or duplex construction with captive clamp. Connects over 00 sizes of MC, AC and Flexible Metal Conduit with just four fittings. Easy to install. Just tilt, insert and snap down. Single-unit construction eliminates loose component parts. Integral red plastic insulated throat bushing provides maximum protection for wire insulation. Materials/Finish: Steel/Zinc Electroplated UL Listed: E-852 For Steel Box Installations CSA Certified: 2850 AMC-50 Trade Size Catalog Dim. in Inches (inches) Number A B C 2 Single AMC Single AMC KO; 4 capacity AMC Duplex AMC AMC-52 UL Standard: 54B CSA Standard: C22.2 No. 8 Exceeds UL specifications for electrical continuity and is suitable as a grounding means under NEC 250.8(5)&(6) and for hazardous locations under NEC 50.4(B), for Class, Div. 2 areas. AMC SELECTION CHART Cable AMC-50 AMC-505 AMC-5 AMC-52** Type 2 KO 2 KO 4 Capacity 4 KO 2 KO Duplex AC Steel 4/2 4/ 4/4 0/4 0/5 0/4 0/5 4/2 4/ 4/4 2/2 2/ 2/4 8/ 8/4 8/ 8/4 2/2 2/ 2/4 0/2 0/ 6/ 6/ HFC Steel 4/2 4/ 4/2 4/ Health Care 2/2 2/ 2/2 2/ Facilities 0/2 0/2 AC Aluminum 4/2 4/ 4/4 0/4 0/4 4/2 4/ 4/4 Interlocked 2/2 2/ 2/4 8/ 8/4 8/ 8/4 2/2 2/ 2/4 MC Steel *4/2 *4/ *4/4 *0/ *0/4 *0/ *0/4 4/2 4/ 4/4 *2/2 *2/ *2/4 *8/2 *8/ *8/2 *8/ 2/2 2/ 2/4 *0/2 *6/2 *6/2 0/2 MC Aluminum 4/2 4/ 4/4 0/ 0/4 0/ 0/4 4/2 4/ 4/4 Interlocked 2/2 2/ 2/4 8/2 8/2 2/2 2/ 2/4 0/2 MC Aluminum 4/ 4/4 *2/2 *2/ 2/4 0/2 0/ MC Aluminum 2/ Flat Flexible Metal Conduit /8 Steel & Alum /2 Steel /2 Steel (Standard and Reduced Wall) *Concrete tight when taped and used with PVC jacketed cable. **Accepts 2 cables of each size listed. 0 N. Frontage Road Skokie, Illinois 600
4 KA2 Notes KA2 0 N. Frontage Road Skokie, Illinois 600
5 KB Cable Connectors For Armored Cable & Flexible Metal Conduit KB Type C & Type 24 Straight Squeeze Connectors To ground and secure Armored Cable and Flexible Metal Conduit to boxes and enclosures. Male hub threads - NPS. Available with insulated throat. Furnished with locknuts. Materials/Finish: UL Listed: E-852 C-5 through C-8: UL Listed for armored cable. UL Listed: E-85 C-8, 24-4 through 24-00: UL Listed for flexible metal conduit UL Listed flexible metal conduit fittings are suitable for use in Hazardous Location under NEC 50.4(B), Class I, Div. II, and suitable as a grounding means under NEC 250.8(5)&(6). Type C-5 End Stopped Insulated Throat Dimensions in Inches Trade Size Catalog Catalog Body Thread Max. Flex. (inches) Number Number Length Length Width Opening 8 ( 2 KO) C-5 2 C-8 C-8T T T T 8 Type C-8 Type Center Stopped T T T Type Type Center Stopped CSA Certified: 5: Armored Cable Type C- Set-Screw Connector To ground and secure Armored Cable to boxes and enclosures. Male hub threads (NPS) Cable stop. UL Listed for armored cable. Furnished with locknuts. Materials/Finish: Malleable Iron/Zinc Plated UL Listed: 852 CSA Certified: 5 Dimensions in Inches Trade Size Catalog Body Thread Max. Flex. (inches) Number Length Length Width Opening 8 ( 2 KO) C-Z UL Listed flexible metal conduit fittings are suitable for use in Hazardous Location under NEC 50.4(B) Class I, Div. II, and suitable as a grounding means under NEC 250.8(5)&(6). UL Standard: 54B CSA Standard C22.2 No. 8 NEMA: FB- Type C-Z 0 N. Frontage Road Skokie, Illinois 600
6 KB2 Cable Connectors For Armored Cable & Flexible Metal Conduit Type AC 45 Angle Squeeze Connectors KB2 To ground and secure Armored Cable and Flexible Metal Conduit to boxes and enclosures. Male hubs - NPS. Provided with center stop. Available with insulated throats. Furnished with locknuts Also suitable for NM and SE cable Type AC-8 Insulated Throat Dimensions in Inches Trade Size Catalog Catalog Body Thread Max. Flex. (inches) Number Number Length Length Width Opening Type AC-50 UL Listed: E-852 UL Listed for armored cable and flexible steel conduit. UL Listed flexible metal conduit fittings are suitable for use in Hazardous Location under NEC 50.4(B) Class I Div. II, and suitable as a grounding means under NEC 250.8(5)&(6). CSA Certified: 5. CSA Certified for armored cable. 8 ( 2 KO) AC-8 AC-8T 8 2 AC-50 AC-50T 5 4 AC-5 AC-5T 2 8 UL Standard: 54B CSA Standard C22.2 No. 8 NEMA: FB Type 25-8C Duplex Connector To ground and secure two Armored Cables to boxes and enclosures. Dimensions in Inches Trade Size Catalog Body Thread Max. Flex. (inches) Number Length Length Width Opening 8 ( 2 KO) 25-8C 2-2 For armored cable 4/2 to 0/2 or combination of sizes Furnished with locknuts. Male hubs-nps Type 25-8C Malleable Iron/Zinc Plated UL Listed: E-852 UL Listed flexible metal conduit fittings are suitable for use in Hazardous Locations under NEC 50.4(B) Class I Div. II, and suitable as a grounding means under NEC 250.8(5)&(6). CSA Certified: 5 UL Standard: 54B CSA Standard C22.2 No. 8 NEMA: FB- 0 N. Frontage Road Skokie, Illinois 600
7 KB Cable Connectors Type AC & Type ACV 0 2-Screw Clamp Connectors 0 Angle Squeeze Connectors For Armored Cable & Flexible Metal Conduit KB To ground and secure Armored Cable and Flexible Metal Conduit to boxes and enclosures. Male hub threads - NPS. All center stopped. Furnished with locknuts. Available with insulated throat Also suitable for NM and SE cable Type ACV-8 Type AC-50 Type AC-200 UL Listed: E-852 ACV-8 through ACV-5: UL Listed for armored cable and flexible metal conduit. UL Listed: E-85 AC-00 through AC-400: UL Listed for flexible metal conduit. UL Listed flexible metal conduit fittings are suitable for use in Hazardous Locations under NEC 50.4(B) Class I Div. II, and suitable as a grounding means under NEC 250.8(5)&(6). CSA Certified: 5 and 584. Armored cable and Flexible Metal Conduit UL Standard: 54B CSA Standard C22.2 No. 8 NEMA: FB- Type ACV-50 Type AC-25 Insulated Throat Dimensions in Inches Trade Size Catalog Catalog Flex (inches) Number Number A B C Opening 8 ( 2 KO) ACV-8 ACV-8T 5 2 ACV-50 ACV-50T 4 4 ACV-5 ACV-5T AC-00 AC-00T AC-25 AC-25T AC-50 AC-50T AC-200 AC-200T AC-250 AC-250T AC-00 AC-00T AC-50 AC-50T AC-400 AC-400T Type AC-250 Type AC N. Frontage Road Skokie, Illinois 600
8 KB4 Cable Connectors For Armored Cable, Flexible Metal Conduit, Interlocked Metal Clad Cables, NM & SE Cable Type KC 2-Screw & 4-Screw Clamp Connectors KB4 To ground and secure Armored Cable, Flexible Metal Conduit and Interlocked Metal Clad Cables to boxes and enclosures. To secure NM and SE Cables to boxes and enclosures. Available with insulated throats. Male hub threads - NPS. All center stopped. Provided with locknuts. UL Listed :E-852, E-858, E-856, E-85 CSA Certified: 5 UL Standard: 54B CSA Standard C22.2 No. 8 NEMA: FB- Type KC-50 Type KC-6 Type KC-00 Type KC-00 Type KC-50 Type KC-500 Insulated UL FILE NUMBER Throat Flex. Trade Size Catalog Catalog Metal Armored Metal Sheathed SE Dimensions in Inches Flex (inches) Number Number Clad Cable Conduit Cable Cable A B C Opening 2 KC-50 KC-50T E-852 E-852 E-852 E-852 E ( 4 KO) KC-5 E-852 E-852 E-852 E-852 E KC-5 KC-5T E-852 E-852 E-852 E-852 E ( KO) KC-6 E-852 E-852 E-852 E E-856 E-858 KC-00 KC-00T E-85 E-856 E KC-25 KC-25T E-85 E-856 E KC-50 KC-50T E KC-200 KC-200T E KC-250 KC-250T E KC-00 KC-00T E KC-50 KC-50T E KC-400 KC-400T E KC-500 KC-500T UL & CSA Listing not applicable N. Frontage Road Skokie, Illinois 600
9 KB5 Cable Connectors For Armored Cable KB5 Type C-5L 2-Screw Connectors Trade Size Catalog Dimensions in Inches Cable (inches) Number A B C Opening To ground and secure Armored Cable to boxes and enclosures. 8 ( 2 KO) C-5L End stopped Male hub threads NPS Provided with locknut Type C-5L UL Listed: E-852 CSA Certified: 5 UL Standard: 54B CSA Standard C22.2 No. 8 NEMA: FB- Front View 0 N. Frontage Road Skokie, Illinois 600
10 KB6 Cable Connectors Aluminum Sheathed For Smooth & Corrugated ALS Cable Type ALS KB6 To ground and secure Aluminum Sheathed Cable to boxes and enclosures. End stopped Male hub thread NPS Furnished with locknut Type ALS End Stopped UL Listed: E-04 UL Listed for smooth and corrugated aluminum sheathed cable. UL Standard: 54B NEMA: FB- Dimensions in Inches Length Length Width Cable Range Catalog K.O. Size of of of Dia. over Armor Number Inches Clamp Thread Clamp Min. Max. ALS N. Frontage Road Skokie, Illinois 600
11 KB Cable and Flexible Cord Connectors For Non-Metallic Sheathed Cable Type C-LS Type 806 & Type 06 2-Screw Connector For round cable-open throat type KB Type C-LS - to secure Non-Metallic Sheathed Cable to boxes and enclosures. Type 806 and Type 06 Series - to secure Non-Metallic Sheathed Cable, Service Entrance Cable and Flexible Cords to boxes and enclosures. Type C-LS Type 806 Type 08 Available with insulated throats Furnished with locknuts. Male hub threads NPS. UL Listed: E-856 UL Listed for 806, 06Z, 08, 0 for NM and SE Cables UL Listed: E-858 UL Listed for 806, 06Z for SE Cable C-LS - UL Listed for NM Cable. Type 0 Insulated Throat Trade Size Catalog Catalog Clamp Opening Dimensions in Inches (inches) Number Number Min. Max. Width A B C Certified File No. 584 NM Cable UL Standard: 54B CSA Standard C22.2 No. 8 NEMA: FB- 2 *C-LS *C-LST T Z 06T T T T *Longer screw to accommodate extra flexible cables. Not CSA Certified N. Frontage Road Skokie, Illinois 600
12 KB8 Cable and Flexible Cord Connectors For Non-Metallic Sheathed Flat Cable Type 806F & Type 06F 2-Screw Connector KB8 To secure Non-Metallic Sheathed Flat Cable, SE/SEU Flat Cable, and other oval (flat) non-metallic cables to boxes and enclosures. 2-screw double clamp - open throat type. Furnished with locknut. Male hub threads - NPS. Type 806F Type 08F Type 0F SEU Cable Range Clamp Opening Catalog K.O. Size (Braid Neoprene Dimensions in Inches Range Number (inches) and PVC Jacketed) A B C Min. Max. Width UL Listed: E-856 UL Listed for NM and SE Cables Certified File No. 584 UL Standard: 54B CSA Standard C22.2 No. 8 NEMA: FB- 806F* 4 #0 to #6 06F #0 to #2 0F 4 # to #/0 08F 2 #/0 to #/0 8 0F 2 #2/0 to #4/0 5 *Not CSA Certified Except PVC #4/0 only N. Frontage Road Skokie, Illinois 600
Cable Connectors For Armored Cable, Flexible Metal Conduit, Interlocked AC-38 Cables, NM and SE Cable
For Armored Cable, Flexible Metal Conduit, Interlocked AC-38 Cables, NM and SE Cable To ground and secure Armored Cable, Flexible Metal Conduit and Interlocked Metal Clad Cables to boxes and enclosures.
More informationAFC Cable Systems: the Cable Industry Leader for Over 80 Years
AFC Cable Systems: the Cable Industry Leader for Over 80 Years AFC Cable Systems, Inc, is proud to announce the launch of two new Type MC cables, MC-Quik and MC-Stat. These two new cables offer the fastest
More informationCorra/Clad MC Cable The contractors cable of choice in place of conduit and wire.
Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire. Installs fast and easy Lowers labor costs Replaces conduit and wire Provides superior grounding UL Listed Corra/Clad MC
More informationNELSON HEAT TRACING SYSTEMS
DESCRIPTION The ALT-LPM Power Connection Kit without Enclosure is constructed of cast aluminum for use with all versions of Nelson Heat Tracing Systems LT, HLT & NC heater cables. Compatible for use with
More informationCOMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods
1. BASIC ELECTRICAL MATERIALS 1. All conduit and raceway must be 3/4" or larger. Exposed raceway in finished areas shall be in 700 or larger wiremold. Exception: runs to individual devices 10 or less,
More informationThe Star Teck Extreme STE/STEX Series Connectors
The Star Teck Extreme STE/STEX Series Connectors Designed to stand up to the harshest and most corrosive environments. Three Generations of Improvements! Spin On, Star Teck, Star Teck Extreme Tray Cable
More informationBand Heaters W A T L O W. Special Mica Barrel and Nozzle
W A T L O W For over 80 years, Watlow has been solving complex and unique application problems with standard mica barrel and nozzle heaters. Watlow is continuously improving design and application knowledge
More informationNELSON HEAT TRACING SYSTEMS INSTALLATION
DESCRIPTION The ALT-BY Tee Splice Connection Kit is constructed of cast aluminum for use with all versions of Nelson Heat Tracing Systems LT, CLT, HLT and NC heater cables. Compatible for use with any
More informationNELSON HEAT TRACING SYSTEMS
DESCRIPTION The PLT-BY Tee Splice Connection Kit is for use with all versions of Nelson Heat Tracing Systems LT, CLT, HLT and NC heater cables. Compatible for use with any vendor s heater cables small
More informationCable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series
Description Page Introduction to Cable Glands 399 EEXe Series 400-401 Polyamide Cable Glands for Unarmored Cable Increased Safety EEXe Series Ex e Certified Ex I Application Entry Thread Seal A2F, E1FX/E2FX,
More informationELECTRICAL SUPPLIES NATIONAL REFRIGERATION PRODUCTS WIRE NUTS HEAT SHRINK TUBING CABLE STAPLES CABLE MARKERS
WIRE NUTS HEAT SHRINK TUBING Color-coded connector shells are made from high dielectric, smooth polypropylene plastic to eliminate porosity and surface cracking. Resists practically all chemical action
More informationInstallation Instructions. For the 18 Built-In Dishwasher and Front Color Panels
Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,
More informationHelically wound resistance wire coil made
Ceramic Insulated CHANNEL STRIP HEATERS A Reliable Heat Source with Seamless Stainless Steel Sheath For Flat Surface Mounting Installations, Used in Hundreds Of Industrial and Commercial Heating Applications...
More informationSECTION (16140) - WIRING DEVICES
SECTION 26 27 26 (16140) - WIRING DEVICES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Receptacles, Connectors, Switches, and Finish Plates. B. Related Sections: 1. Section 00 31 13.43 (00370) -
More information2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK
PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 27 12 23 FIBER OPTIC DATA NETWORK A. Furnish, install, terminate, and test all fiber optic equipment and cabling necessary for a complete and functional data highway
More informationInstallation Instructions
Installation Instructions TWSD16128PHC-UL Page 1 Introduction The TWSD16128PHC-UL is intended to be used with UL listed WLN / Networking devices both indoors and outdoors and to provide NEM 3R protection
More informationCORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES
CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES INDEX Corflex MC-HL Instrumentation - Pairs and Triads (0V*)... 1 - CORFLEX Cables
More informationSECTION BASIC ELECTRICAL MATERIALS AND METHODS. A. This Section includes basic electrical materials and methods including:
SECTION 16050 BASIC ELECTRICAL MATERIALS AND METHODS PART 1 - GENERAL 1.01 SUMMARY A. This Section includes basic electrical materials and methods including: 1. Conduit, fittings and accessories. 2. Wire,
More informationVibratone Horns. Models 350 and 450
FEDERAL SIGNAL CORPORATION Vibratone Horns Models 350 and 450 DESIGNED FOR ROUTINE SIGNALING Range of up to 200 feet Coded or sustained tones Model 350 12, 24, 120 and 240VAC; Model 450 12, 24, 125 and
More informationB C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM
Ceramic Insulated A Reliable Heat Source with Seamless Stainless Steel Sheath Flat Surface Mounting Installations Used in Hundreds of Industrial and Commercial Heating Applications Typical Applications
More informationB C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM
Ceramic Insulated A Reliable Heat Source with Seamless Stainless Steel Sheath Flat Surface Mounting Installations Used in Hundreds of Industrial and Commercial Heating Applications Typical Applications
More informationNELSON HEAT TRACING SYSTEMS
DESCRIPTION The Z1-PLT-BC Power Connection Kit is designed for terminating on heater cable to customer supplied power wiring. This kit is designed for use with all wattages of Nelson Heat Tracing Systems
More informationNorth American Cable Glands
North American Cable Glands INTRODUCTION Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable supply of energy and information
More informationContender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof
Contender Series Factory Sealed Manual Motor Starters and Contactors Applications Manual motor starters are available to meet any plant installation requirement. They may be used to install a variety of
More informationNELSON HEAT TRACING SYSTEMS
DESCRIPTION The SLT-LPS Entry Seal Kit provides a watertight entry into a junction box suitable for this application. This kit includes cable seals for power and end terminations. The SLT-LPS kit is designed
More informationCORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES
CORFLEX TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES INDEX Instrumentation Cables - Pairs and Triads (0V*)... 2 - The Original MC-HL Technology In 1958 Canada Wire and Cable, which s now part of Nexans,
More informationCirculation Heaters Selection Guidelines
Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation
More informationContender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof
Contender Series Factory Sealed Manual Motor Starters and Contactors Controls NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION MOTOR STARTERS Applications Manual motor starters are available to meet any plant
More informationS1L Series: Metal Bottom
S1L Series: Metal Bottom Product Features and Benefits Long life element: Patented PTC heater element lasts longer than conventional heaters Will not burn out if run in air Will not burn out due to scale
More informationFRP HEATING SYSTEM INSTALLATION, OPERATION & MAINTENANCE MANUAL FRP.IOM.R1
FRP HEATING SYSTEM INSTALLATION, OPERATION & MAINTENANCE MANUAL FRP.IOM.R1 Hotfoil, Inc. Robbinsville, NJ 08691 Phone: 609.259.4118 / Fax : 609.259.4119 http://hotfoil.com TABLE OF CONTENTS I Product Specification
More informationInstallation Instructions
Installation Instructions TWSD16128PHC Version 1.1 - Page 1 Introduction The TWSD16128PHC is intended to be used with WLN / Networking devices. The TWSD16128PHC is intended to be used both indoors and
More informationNELSON HEAT TRACING SYSTEMS
DESCRIPTION The PLT-L Series End of Circuit Light Kit is for use with all versions of LT, CLT, HLT and NC heater cables. Compatible for use with any vendor s heater cables smaller than 11mm (.44 ) diameter.
More informationNELSON HEAT TRACING SYSTEMS
DESCRIPTION The D1CMD Class I Div. 1 Continuity Monitor Device provides the cable termination and explosion proof seal parts needed to make the power end electrical connections associated with Nelson Heat
More informationNELSON HEAT TRACING SYSTEMS ALT-BC STANDARD POWER CONNECTION KIT
DESCRIPTION The ALT-BC Standard Power Connection Kit is constructed of cast aluminum for use with all versions of Nelson Heat Tracing Systems LT, CLT, HLT and NC heater cables. Compatible for use with
More informationHeavy Industrial/Marine MaxGard
6 Heavy Industrial/Marine MaxGard MaxGard Interconnection Systems Overview Defined Any application where electrical connections need protection from water and/or dust ingress to contacts or wiring compartment
More informationTABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19
TABLE OF CONTENTS About This Textbook...xi How to Use the National Electrical Code... 1 Article 90 Introduction to the National Electrical Code... 7 90.1 Purpose of the NEC... 7 90.2 Scope of the NEC...
More informationC Electrical Connection Kit
1548-4010C Electrical Connection Kit For Use With Dekoron 2700 and 2300 Family of Heating Cables Installation Instructions Kit Description The Dekoron 1548-4010C electrical connection and end seal kit
More informationElectricity Unit Notes. Agriculture Mechanics I
Electricity Unit Notes Agriculture Mechanics I Principles of Electricity Electricity is a form of energy that can produce light, heat, magnetism, chemical changes Resistance: tendency of a material to
More informationInstallation Instructions
Installation Instructions For the 18" Built-In Dishwasher Sears, Roebuck and Co. Sears Canada, Inc. Hoffman Estates, IL 60179 U.S.A. Toronto, Ontario, Canada M5B 2B8 154435201 Before You Begin DO NOT INSTALL
More informationBAND HEATERS TYPICAL APPLICATIONS: SPECIAL OPTIONAL FEATURES: Plastic Injection Molding. Two piece construction. Plastic, Food, or Candy Extruders
Durex provides a complete line of mica and ceramic band heaters used extensively for injection molding and extrusion applications. Operating at temperatures up to 1200 F, these heaters are an economical
More informationNELSON HEAT TRACING SYSTEMS
DESCRIPTION The Z1-PLT-LPM Power Connection Kit is designed for terminating one heater cable to customer supplied power wiring. This kit is designed for use with all wattages of Nelson Heat Tracing Systems
More informationSECTION ELECTRICAL GENERAL PROVISIONS
PART 1 GENERAL 1.01 SECTION INCLUDES A. General provisions for Electrical Systems B. Wire and cable for 600 volts and less. C. Wiring connectors. D. Electrical tape. E. Heat shrink tubing. F. Wire pulling
More informationSmart Products. Ingenious Solutions.
THE FUTURE IS ON Smart Products. Ingenious Solutions. Wiring Devices, Energy Management Solutions and Commercial Data Infrastructure Products L-200 Corporate Information 8 World Headquarters... 8 The Future
More informationChapter 1 General... 5
About This Textbook...xi About the National Electrical Code...xv About the Authors and Illustrator...xix About the Team...xxi Article 90 Introduction to the National Electrical Code... 1 90.1 Purpose of
More informationCirculation Heaters Selection Guidelines
Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation
More informationUL Topic III. Converting European EEx Certificates. Into. North American Division Certificates
Note: While this material was originally prepared for presentation in February 1999, it has been updated to reflect the evolving technical requirements now applicable as of April 2003. UL Topic III Converting
More informationStar Teck. Teck and Tray Cable Fittings. Table of Contents
Table of Contents The Whole Family...A2 A3 Specifications... A4 A5 Hazardous Locations CEC Classifications... A6 A9 Hazardous Locations Class, Zone and Division Certifications... A10 Quick Reference...A11
More informationMaxGard. Interconnection Systems. Durability. Performance. Safety
8Russellstoll Pin and Sleeve Power Connectors Safety Different power supply ratings can t mix: 24 single-rate device polarizations ensure exact voltage, frequency and phase differentiation Safe connections:
More informationMarathon Special Products
Marathon Special Products Fused Disconnect Switch Specifications 30 amps 600 volts AC Line/Load #4-18 AWG Factory & Field Wiring Minimum indicator voltage 90V-AC Din-Rail mountable on any 35mm wide rail
More informationIDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER
IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER Published 3/23/2012 T hough rapidly increasing in popularity, tray cables are still a point of confusion for many. While the term tray cable
More informationACCESSORIES GUIDE. RobroyEnclosures.com. Market-Leading Non-Metallic Enclosure Brands
ACCESSORIES GUIDE Market-Leading Non-Metallic Enclosure Brands RobroyEnclosures.com ROBROY ENCLOSURES RobroyEnclosures.com 500 Maple Street, Belding, MI 48809 P 616.794.0700 A Robroy Enclosure Accessories
More informationEJB Custom-Built Control Panels
EJB Custom-Built Control Panels Cl. I, Div. 1 & 2, Groups B*, C, D Cl. I, Zones 1 & 2 Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III UL and cul approved Ex d IIB + H2 T6 Certified to
More informationNELSON HEAT TRACING SYSTEMS
DESCRIPTION The ALT- continuity monitor device is used to monitor bus continuity on a parallel type heater cable. After the heater cable is installed on the pipe, connect the ALT- to the opposite end of
More informationCIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES
CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by
More informationCIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)
Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Shortest Lead Times Standard 8-10
More informationELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. U.S.A. WARNING FOR YOUR
More informationMineral Insulated Band Heater
The MI band heater is a high-performance heater. Its performance and name are derived from exclusive mineral insulation a material with much higher thermal conductivity than mica and hard ceramic insulators
More informationCIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES
CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index
More informationSecond Revision No. 601 NFPA [ Section No [Excluding
Second Revision No. 601 NFPA 70 2015 [ Section No. 300.4 [Excluding any Sub Sections] ] Where subject to physical damage, conductors, raceways, and cables shall be protected. Informational Note: Minor
More informationULTRA-SAFE Explosion-proof Duct Heaters
Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer
More informationPipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters
Pipe Thread Heaters Construction Features " -/" Pipe Thread Heaters Element bends repressed uniformly to insure electrical insulation integrity. One piece forging hex, thread and riser assures reliability.
More informationA. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod
Journeyman and Master Common Exam 2 1 The grounding terminal of a grounding-type receptacle installed in a metal box shall be? A. Connected to the equipment ground B. Bonded to the box C. Connected to
More informationREFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS
*s are Subject to Change without Notice.* REFLECTOR PANS FOR HINGED ELEMENTS Heavy Chromed Steel Description 2-1040 6" UNIVERSAL $2.19 2-1041 8" UNIVERSAL $2.89 2-1050 6" GE/HOTPOINT $2.39 2-1051 8" GE/HOTPOINT
More informationMECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 8/10/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions
MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 8/10/11 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. Is low voltage cable allowed to be run through drilled
More informationCADDY CORPORATION. Utility Distribution Systems
Food Service Equipment Air Systems Utility Distribution Systems page 1 of 2 Equipment Specifications General Specifications Caddy Corporation of America Energy Distribution and Management System, which
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 26 0519 LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationCartridge Heaters. Components. Application Guidelines
Application Guidelines Up to 1.297" Dia. Up to 60" Lengths Up to 11,500 Watts 120 and 240 Volt Up to 1400 F Max. Working Temp. Modification Available to Fit Custom Applications Type CIR cartridge heaters
More informationTubular Industrial Process
Application Tempco Over-the-Side Immersion Heaters are specifically designed for heating fluids in tanks. Depending on the tank shape, size, accessibility and working area inside the tank, choose a round
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS HPR SERIES PROOFER/RETARDER MODEL HPR1 ML-132406 30 In. (Standard) ML-132407 50 In. (Standard) ML-132408 63 In. (Standard) ML-132409 83 In. (Standard) ML-132410 96 In. (Standard)
More informationtemperature Controllers
temperature Controllers Bulb and Capillary Thermostats Thermostat Styles and Selection Construction Characteristics This type of control operates by expansion and contraction of a liquid in response to
More informationINSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS I. GENERAL Heatrex Explosion-proof Pipe Thread Mounted Immersion Heaters are CSA approved
More informationELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. WARNING FOR YOUR SAFETY:
More informationFreezer Frost Heave Prevention
Freezer Frost Heave Prevention 1. Pipe Freeze Protection and Flow Maintenance RaySol System Mineral Insulated Heating Cable System This step-by-step design guide provides the tools necessary to design
More informationDIVISION 16 ELECTRICAL
DIVISION 16 ELECTRICAL Saratoga Springs / standards / 02-2004 Page - 0 ELECTRICAL SECTION 16060 GROUNDING AND BONDING PART 1 GENERAL 1.01 SECTION INCLUDES A. Grounding electrodes and conductors, equipment
More informationTop Products - Modified HVAC Catalog
Catalog Table of Contents AIR CONDITIONING/REFRIG SUPPLIES...1 AIR FILTRATION...2 BALL VALVES...3 BATTERIES...3 BLACK FITTINGS...4 BLACK NIPPLES...5 BLACK PIPE...8 BRASS PIPE FTGS & HOSE BARB, HOSE FTGS...8
More informationInstallation Instructions
Installation Instructions 30" ELECTRIC Downdraft Cooktop Modules selected at time of purchase IMPORTANT: Read and save these instructions. Part No. 208040 A 438589 Quick Reference Table of Contents: Pages
More informationVibratone Horns. Models 350 and 450
FEDERAL SIGNAL CORPORATION Vibratone Horns Models 350 and 450 DESIGNED FOR ROUTINE SIGNALING Range of up to 200 feet Coded or sustained tones Model 350 12, 24, 120 and 240VAC; Model 450 12, 24, 125 and
More informationMODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS
Specifications subject to change without notice. USA 150303 Page 1 of 10 MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS Specifications subject to change without notice.
More informationSN Series - Safety Shower Heaters Tankless Water Heating Solutions
36-144 kw (122,800-491,300 BTUs) Temperature overshoot purge system Lead-Free Design NEMA 4 enclosure standard ETL and cetl certified to UL and CSA Standards Liquid-Cooled Solid State Relays Internal fusing
More informationChromaStar. Comfort. Infra-Red Radiant Heaters. Description. Portable. Applications. Fixed Overhead. 1.5 to 13.5 kw. 5,118 to 46,062 BTU/Hr
1.5 kw 4.5 kw 4.5 kw 2.0 kw 1.5 to 13.5 kw 5,118 to 46,062 BTU/Hr 6.0 kw 120, 208, 240, 277, 480, and 600 Volts 6.0 kw Single or 3 Phase - Most Models Field Convertible 13.5 kw Fixed Overhead - Convertible
More informationThe Next Generation of Greenfield Connectors. Our flex System is Your Solution for Electrical Runs
1/2 to 2 Solid Steel or luminum The Next Generation of Greenfield onnectors SPE-flex Our flex System is Your Solution for Electrical Runs connectors Since 1946 Straight onnectors for Enclosures or Use
More informationInstallation Instructions
Installation Instructions Before you begin... 2 Location... 2 Recommended grounding instructions... 2 Electrical requirements... 2 Exhaust requirements... 3 Water supply and drain requirements... 3 Please
More informationOzone Generator Systems
PZ2-1 & PZ2-2 - Commercial and Residential Pools & Spas Ozone Generator Systems INSTALLATION GUIDE and OPERATION MANUAL T. O3 NATURAL TECHNOLOGY Reduces Chemical Usage, Improves Sanitation Produces Crystal
More informationCartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data
W A T L O W The Watlow FIREROD not only set the industry standard for cartridge heaters, it continues making improvements in construction and design. Among those improvements is the metric FIREROD, a variation
More informationPiggyback Mechanical Float Switch. Piggyback Vertical Mechanical Float Switch. Piggyback Diaphragm Switch. Accessories
Piggyback Mechanical Float Switch Piggyback Vertical Mechanical Float Switch Residential sewage waste transfer RFSN-6, RFSN-9 and RFSN-10 any manual pump, up through 3/4 convert any manual pump, up hp
More informationCLASSIFICATION COMPARATOR
CLASSIFICATION COMPARATOR THE IEC/NEC COMPARATOR World standards for the classification of hazardous areas are moving toward harmonization. The 999 U.S. National Electric Code (NEC ) and the 998 Canadian
More informationWarnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5
TABLE OF CONTENTS Warnings 2 Installation Instructions 3 Wiring Instructions 3 Mounting Instructions 4 Replacement Element Installation 5 Replacement Parts 5 Heater Coverage Areas 6 General Notes 6 Maintenance
More informationTitle: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards
Change History Date Description of Change Pages / Sections Modified Change Approver Initials 8/1/17 Updated section on Manufacturers 3 1. 6/15/16 Updated division section from 16120 to 26 05 00, - mgl44
More informationLHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy.
Technical Specifications Description The High Bay luminaire delivers the illumination performance to replace up to a 400W HID fixture one-for-one. Lumecon s unique High Bay design makes this fixture an
More informationDRYER INSTALLATION INSTRUCTIONS
DRYER INSTALLATION INSTRUCTIONS Table of Contents DRYER SAFETY... 1 INSTALLATION REQUIREMENTS... 2 Tools and Parts... 2 Location Requirements... 3 Electrical Requirements... 5 INSTALLATION INSTRUCTIONS...
More informationIndustrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers
Features and Benefits Corrugated armor Mechanical protection Low-smoke/zero-halogen (LSZH ) sheath Key life-safety benefit Meets cyclic impact and chemical resistance test Superior performance Tray-rated
More informationHPNLS-LO. Installation Manual
Installation Manual WARNING: DO NOT LIFT FIXTURE BY CABLES. Do not attempt to install or use the fixture without reading the installation instructions and safety labels completely. This could result in
More informationB. Product Certificates: For each type of meter and gage, from manufacturer.
Page 220519-1 SECTION 220519 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationEngineering Submittal Data PPRTH Patio Radiant Tube Heaters.
12288 Brawn Road 22, Wainfleet, Ontario, Canada L0S 1V0 Phone: 905-899-3473 Fax: 905-899-2262 www.easyradiantworks.com email: erw@vaxxine.com P For either indoor or outdoor installation. Not for use in
More informationPipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters
Construction Features 1" 2-1/2" Pipe Thread Heaters Element bends repressed uniformly to insure electrical insulation integrity. One piece forging of hex, thread and riser assures reliability. Element
More informationSERGE BARIL HEAT TRACING SYSTEMS
DESCRIPTION The HA-P Hazardous Area Seal Kit provides the cable termination and explosion proof seal parts needed to make the power end electrical connections associated with Serge Baril Heat Tracing Systems
More informationElectric Dryer Installation Instructions
Electric Dryer Installation Instructions Table of Contents DRYER SAFETY...2 Installation Requirements...3 Tools and Parts... 3 Location Requirements... 3 Electrical Requirements... 4 Install Leveling Legs...
More informationELECTRIC SPA-PAK HEATER INSTALLATION & OPERATING INSTRUCTIONS
ELECTRIC SPA-PAK HEATER INSTALLATION & OPERATING INSTRUCTIONS CATALOG NO.: 6100.53O Effective: 03-15-05 Replaces: 02-01-05 INTRODUCTION The SPA-PAK Spa Heaters have been designed to provide efficient,
More informationVentilating Fan FV-05VFL2 FV-08VFL2 FV-11VFL
Ventilating Fan FV-05VFL FV-08VFL FV-VFL READ AND SAVE THESE INSTRUCTIONS. Please read these instructions carefully before attempting to install, operate or service the Panasonic Ventilating Fan. Failure
More informationAll surfaces shall be restored where surface finish damage is evident. Physical material damage will require replacement of part.
General This standard sets forth the minimum requirements for basic electrical materials and methods used in construction on University projects. It is not intended to be used as a complete specification
More information