Standard Devices. Electronic Alarm Indication Systems. ME 3011b

Size: px
Start display at page:

Download "Standard Devices. Electronic Alarm Indication Systems. ME 3011b"

Transcription

1 Standard Devices Electronic Alarm Indication Systems ME 3011b

2 Before connecting and powering this device, please read carefully the manual, and refer to it whenever you have any doubts. This brochure is subject to changes without previous advice.

3 Table of Contents Contents Page Operation Principle 4 Technical Data 5 Modularity and Arrangements 6 Dimensions 7 Front Display Engraving Signaling Sequences 9 Special Options 10 e.tool ME 3011-view Visualization via Serial Interface 11 Electronic Alarm Indication Systems ME 3011b 3

4 Operation Principles The alarm annunciators have the main function of safely signaling critical status of installations, aiming at their integrity. They signal acoustically and optically equipment alarms in a standardized way, within the highest ergonomic and cognitive possible standard. It is recommended, in general, to carry out the direct connection of electric field alarm signals to the annunciator, preventing loops through digital automation and control systems. Thus, the necessary operating safety level is achieved. The maximum alarm signal cable length is 600 m (unshielded) or 1000 m (shielded). These maximum values may be strongly reduced in areas of very high electromagnetic fields, for example in the case of open air cable trays within substations. It is, also, of paramount importance to place the signal cables in trays carrying cables with homogeneous voltages. Placing high and low voltage cables in conjunction within the same cable tray may cause serious annunciator malfunctions or even hardware damages. The ME 3011b annunciator, the new member of Mauell annunciator family, keeps one of the most important characteristics of ME 3010b series, which is the modularity of the alarm windows. The processing fundament of the alarm signs is now carried out through last generation micro controllers, with high performance RISC architecture. So, ME 3011b annunciator incorporates all the advantages of a micro processed system, such as configuration of the annunciators main functions through the front keyboard, or also via configuration software for download. This way, the ME 3011b annunciator provides all conventional functions of alarm announcing together with new and advanced communication function in local network and event recording, among others. These functions will be described in details throughout the manual. Alarm Annunciator ME 3011b 4 Electronic Alarm Indication Systems ME 3011b

5 Technical Data 1 Supply Voltage 1.1 PS-05 Power Supply Standard 24 Vdc ± 20 % 1.2 PS-02 Power Supply Input 19 to 264 Vdc and/or (Option) 90 to 264 Vac Output 24 Vdc/0.75 A 1.3 Special Option PSFD Power Supply Fault Detector for Vdc and/or Vac Note: All power supplies are integrated into the annunciator 2 Inputs 2.1 Alarm Inputs 4 up to 252 Isolation Optical couplers Input Voltages 24, 4, 60, 110/125 Vdc and 110/127, 220 Vac, ± 20 % Input Current 3 ma (typical) Input Filter lower value = 5 ms, programmable in steps of 2.5 ms 2.2 External Push-Button Station 24 Vdc Isolation Opto couplers Functions Sound Acknowledge (HA) Light Acknowledge (LA) Reset (RE) Light Test / Function Test Sleep Mode (SLM) Keyboard OFF (KBOFF) 2.3 Synchronism with GPS and/or Flashing 24 Vdc Isolation Opto couplers 3 Outputs 3.1 Relays 3 freely programmable relays for various functions, e.g., external buzzer, voltage fault, alarm group, etc 3.2 Sound Indication 90 db / 10 cm, 4 khz 3.3 Repeat relays 1 contact for each alarm point, Note: Field voltages over 125 Vdc or Vac for resistive load. Maximale switching voltage 125 Vdc/250 Vac 4 Interfaces 4.1 Communication Standard RS232TTL bi-directional 4.2 Communication RS232C RS232C bi-directional Option Baud rate: 9600, n,, 1 Protocol: Modbus RTU (Slave) or Modbus RTU (Slave)+TS 4.3 Communication RS 45 bi-directional serial communication (configurable) Baud rate: 110 to Parity: even, odd or none Stop bit: 1 or 2 Protocol: Modbus RTU (Slave) Event Register (Option) 5.1 Events 1000, with time stemp 5.2 Resolution 1 ms, samples 2.5 ms 5.3 Interfaces Rs232C or RS Protocols Mauell or Modbus RTU (slave) -TS 6 Visualization 6.1 Light Indication Back light Led Special Option Back light available in red, yellow, green white and blue colors 5 mm visible red, yellow and green color leds More than 1 color per annunciator 6.2 Flashing frequency Fast: approx. 1.2 Hz Slow: approx. 0.4 Hz 6.3 Windows Dimension 24 mm x 4 mm Back light White translucent modules Led Gray RAL 7032 polycarbonate modules 7 General 7.1 Alarm sequence ISA 1, 1A, 1B, 2A, 2C, 4A; 4AR others on request 7.2 Environment Operation temperature -20 to 55 C Storage temperature -20 to 0 C Relative Humidity 0 to 95 %, without condensation 7.3 Protection class Front IP41 Enclosure IP Isolation 2 kv, 60Hz, 1 min. in compliance with IEC Terminals Terminal connectors (removable) for cables up to 2.5 mm 2 Electronic Alarm Indication Systems ME 3011b 5

6 Modularity and Arrangements The minimum configuration possible for the annunciator is a central module with 4 alarm points, and dimension of 2v x 4h or 4v x 2h (see shaded portion on lower right corner of diagram below). Expansion modules can be added to this central unit, with 4 or alarm points each, always in 2v x2h or 2v x 4h modularity basis. So the subsequent configurations are, 12, 16, 20, 24, 2 points and so on, up to a maximum of 252 alarm points. The module arrangement follows the diagram below. Enclosure arrangement Nr. of Points Arrangement 4 2v x 4h 2v x 4h 2v x 6h 6v x 2h 12 4v x 4h 2v x h 16 10v x 2h 2v x 10h 12v x 2h 20 6v x 4h 4v x 6h 2v x 12h 24 14v x 2h 2v x 14h 16v x 2h 2 v x 4h 4v x h 2v x 16h 32 1v x 2h 6v x 6h Nr. of Points Arrangement 20v x 2h 36 10v x 4h 4v x 10h 40 22v x 2h 12v x 4h 44 v x 6h 6v x h 4v x 12h 4 26v x 2h 2v x 2h 52 14v x 4h 4v x 14h 56 10v x 6h 6v x 10h 16v x 4h 60 v x h 4v x 16h 6 1v x 4h 6v x 12h 76 20v x 4h 10v x h Nr. of Points Arrangement 4 22v x 4h 24v x 4h 92 12v x h v x 12h 6v x 16h 10 14v x h v x 12h v x h v x 16h 140 1v x h 12v x 12h v x h 10v x 16h v x 12h v x h 1 24v x h 16v x 12h 12v x 16h 212 1v x 12h v x 16h Nr. of Points Arrangement v x 12h v x 16h 6 Electronic Alarm Indication Systems ME 3011b

7 Dimensions 9.5 L = h x A = v x RUN FA ME 3011 T 114 Cutout Table (height v x width h) mm x mm h (x) Points x x 3-52 x x x x x x x x x x x x x x 3-14 x x x x x x x x 772 v x x x x x x 772 (y) x x x x x x x x x x x x x 3-3 x 50-3 x x x x x x x x 3-44 x x x x x x Electronic Alarm Indication Systems ME 3011b 7

8 Front Display Inscriptions 1 Low Relief Engraving 1.1 Back Light Display LB 24 x 4 White Translucent - Code : Character height = 3 mm Maximum number of characters per line = 19 Maximum number of lines = ABCM DRFTG MDMCD ABCM ABCDEFGHJKLMNOPRSTU ABCDEFGHJKLMMMP ABCDEFGHJKLMM LED Display MK 24 x 4 - RAL 7032 color - Code : Character height = 3 mm Maximum number of characters per line = 15 Maximum number of lines = ABCDEFGHIJKLMNOP ABCDEFHJKLMM ABCDEFGHJKLMNOP ABCDEFG ABCDEFHJKLMMMP ABCDEFGHJKLMM ABCDEFHJKLMMMP Electronic Alarm Indication Systems ME 3011b

9 Signaling Sequences The ME 3011b can be configured in order to comply with 16 signaling sequences. Among them the most important are the following: ISA-RP 1.1/(ISA-S1.1) ISA-1/(A), ISA-1A/(A-5), ISA-1B/(A-4), ISA-2A/(R-), ISA-2C/(M), ISA-4A/(F1A), ISA-4AR/(F1M) etc. Other sequences can be implemented on request. ALARM SEQUENCE REF ISA ALARM NORMAL ABNORMAL ACKNOWLEDGE BACK TO BACK TO ACKNOWLEDGE RESET SOUND LIGHT NORMAL NORMAL BEFORE SOUND LIGHT ACKNOWLEDGE ISA 1 (A) ISA 1A (A-5) ISA 1B (A-4) LIGHT SOUND LIGHT SOUND LIGHT SOUND ISA 2A LIGHT F F S F F S (R-) ISA 2C (M)default SOUND LIGHT SOUND PRIMARY SIGNAL SEQUENCE (1 st Event) BACK TO NORMAL REF ALARM NORMAL ABNORMAL ACKNOWLEDGE BACK TO NORMAL BEFORE ACKNOWLEDGE RESET ISA ACKNOWLEDGE INITIAL SUBSEQ INITIAL SUBSEQ INITIAL SUBSEQ INITIAL SUBSEQ INITIAL SUBSEQ ISA 4A Light Sound ISA 4R Light Sound LEGEND F = Fast LED Off Siren = Off LED On S = Slow LED intermittent Siren On Electronic Alarm Indication Systems ME 3011b 9

10 Special Options 1 Light Display with more than one color In this case, the quantity and position for each color must be requested by the customer. For LED Display up to 3 colors in red, yellow or green For Back Light Display up to 5 colors in red, yellow, green, white or blue 1.1 Back Light Socket In this option, the SMD Back Light LED is socket mounted and plugged on the annunciators PCB. It allows to change the indicating light color for the individual alarm points. The socket Back Light LED must be specified at ordering the annunciator, as a special factory option. 2 - ES-00 Empty Slot If the total alarm points amount of the annunciator enclosure is higher than demanded, it is possible to provide empty slots, each with alarm points. The position of the empty slot is defined due to the physical adress of each module, and must attent to the tables below. The empty slot is always the last, following the pointer direction. The empty slots for Back Light are delivered with the translucent Back Light Display and the LED Version with the RAL 7032 Display v x 4h Empty Slot v x h Empty Slot ES ES CM CM Electronic Alarm Indication Systems ME 3011b

11 e.tool ME 3011-view Visualization via Serial Interface The e.tool ME3011-view is a ME3011b dedicated software that allows the visualization of the event registers from up to 10 annunciators in one NET. For more information, please consult our Sales Department at info@mauell.com RS232C (option) with 5, 10 or 15 m cables event recording with 1,0 ms resolution with samples each 2,5 ms enhanced maintenance oriented functions advanced communication protocols TCP/IP interface up to 10 annunciators in one NET Electronic Alarm Indication Systems ME 3011b 11

12 Representatives Germany Helmut Mauell GmbH Am Rosenhügel 1 7 D Velbert Tel.: +49 (0)20 53 / 1 30 Fax.: +49 (0)20 53 / Internet: info@mauell.com For an up-to-date list of all our representatives and branch offices, please visit our homepage: Representatives and Branch Offices All Over The World: Abu Dhabi U.A.E. Argentina Austria Belgium Brazil Czech Republic Denmark Finland France Great Britain Hungary Iran Korea Kuwait Netherlands Norway Poland Singapore Spain Sweden Switzerland Turkey USA E07

ME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems

ME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems Electronic Alarm Indication Systems ME 3011 compact Power Station Control Systems Power Distribution Control Systems Control Room Technology Automation Equipment 2 Table of Contents Contents Page System

More information

Alarm Systems. Digital Alarm Annunciator. ME 3011b Instruction Manual SERIAL PRODUCTS. Manual ME3011b_E_v0707_Pre.doc 1/50

Alarm Systems. Digital Alarm Annunciator. ME 3011b Instruction Manual SERIAL PRODUCTS. Manual ME3011b_E_v0707_Pre.doc 1/50 Alarm Systems SERIAL PRODUCTS Digital Alarm Annunciator ME 3011b Instruction Manual Manual ME3011b_E_v0707_Pre.doc 1/50 1 Information and Technical Data Introduction 4 Warranty 4 Installation 5 Operation

More information

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21 Electronic Standard Devices Annunciator Relay MR and MRE MR 2 and MRE 2 The products described in this brochure are intended for industrial use and meet the requirements laid down by the EU directive 7

More information

ME 3011C / Alarm Indication / Quick Reference Guide

ME 3011C / Alarm Indication / Quick Reference Guide Tables of Contents Page Application 1 Features 1 Important Safety Information! 2 Note to this Guide 2 Further Information 2 Device Variants 2 General Functions 3 Annunciator Sequences - ISA 18.1 3 Plan

More information

Alarm Systems. Digital Alarm Annunciator. ME 3011b Instruction Manual SERIAL PRODUCTS. Manual ME3011b_E_r07 at 1/68

Alarm Systems. Digital Alarm Annunciator. ME 3011b Instruction Manual SERIAL PRODUCTS. Manual ME3011b_E_r07 at 1/68 Alarm Systems SERIAL PRODUCTS Digital Alarm Annunciator ME 3011b Instruction Manual Manual ME3011b_E_r07 at 1/68 1 Information and Technical Data Introduction 4 Warranty 4 Installation 5 Operation Principles

More information

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21 Power Station Control Systems Power Distribution Control Systems Control Room Technology Automation Equipment The products described in this brochure

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

AIS750 Series Alarm Annunciator

AIS750 Series Alarm Annunciator Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual &

More information

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014) AIS750 Series Alarm Annunciator User Manual (Ver 23 / JUNE 2014) 3-350 John Street, Thornhill, tario L3T 5W6 Phone: 289 597 APEX (2739) Fax: 289 597 2200 Toll Free: 1 866 776 2943 Email: mail@annunciatorca

More information

Signal Processing System ME30 infobox

Signal Processing System ME30 infobox M process IT Signal Processing System M infobox cquire, process and display from to alarm signals or status messages onfigurable signal functions ommunication-interfaced signaling devices equipped with

More information

DRAFT 20 October 2014

DRAFT 20 October 2014 Technical data MTL process alarm equipment EPS rev 8 Programmable alarm annunciator Modular construction from 1 to 256 alarm channels Multi-redundant design so there is no single point of failure Choice

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The nvent RAYCHEM NGC-40 is a multipoint

More information

Annunciator Unit SACO 16 D1. Product Guide

Annunciator Unit SACO 16 D1. Product Guide Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Flexible, field-customizable 16-channel annunciator unit Alarm channels activated by normally open

More information

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS PRODUCT INFORMATION VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS Tunnel sensors EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY

More information

Annunciator unit. Application

Annunciator unit. Application Issued: April 1999 Status: April 1999 Version: B/09.11.2001 Data subject to change without notice Features Flexible, field-customizable 16-channel annunciator unit Alarm channels activated by normally

More information

System 9000TS Sequence of Events Recorder

System 9000TS Sequence of Events Recorder System 000TS Sequence of Events Recorder ms Event Recorder and combined Annunciator Modular, rack mounting design expandable to over 000 inputs ms time stamping of events across the whole system Up to,000

More information

AO Annunciator Module

AO Annunciator Module General Specifications GS48C43Z01-00E-N AO-543-01 Annunciator Module GENERAL Figure 1 This module has two independent annunciator circuits. The circuits handle fault signals and operator actions (acknowledge,

More information

Series 725 Programmable Alarm Annunciator

Series 725 Programmable Alarm Annunciator Series 725 Programmable Alarm Annunciar Multi-redundant design for greater reliability Modular construction from 1 256 alarm channels Multi-redundant design so there is no single point of failure Choice

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The Raychem NGC-40 is a multipoint electronic

More information

OO Measuring range from bar rel. OO Large selection of pressure sensors. OO Automatic sensor recognition

OO Measuring range from bar rel. OO Large selection of pressure sensors. OO Automatic sensor recognition Hand-Held Pressure Measuring Devices with External and Integrated Pressure Sensors measuring monitoring analysing HND-P OO Measuring range from 0...1000 bar rel. OO Measuring accuracy starting with ±0.1%

More information

Return loss measurement of fiber optic components

Return loss measurement of fiber optic components Return loss measurement of fiber optic components Solutions Brief 815-1 How the HP 8153A/HP 81534A measure return loss of fiber optic components? The significance of return loss The introduction of new

More information

M2500 Engine Controller Installation Manual

M2500 Engine Controller Installation Manual M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...

More information

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1- DPR-45 User Manual V-2.0 (2..206) DPR-45 TEMPERATURE PROTECTION RELAY PT00 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT 9-50VDC SUPPLY DESCRIPTION DPR-45 is a precision unit designed for the temperature

More information

X11CA COMPUTER ANNUNCIATORS

X11CA COMPUTER ANNUNCIATORS S E R I E S XCA COMPUTER ANNUIATORS E N G I N E E R I N G C O M P A N Y The Ronan Series XCA Computer Annunciators are the latest generation of Ronan s state-of-the-art annunciators offered in window models.

More information

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device Safety Instructions Used symbols Important Comments Before starting with installation of the MS 10B Alarm Unit, we recommend you to read the important information beneath. Qualification The installation

More information

Operation Manual Part-No

Operation Manual Part-No Version 2.2, 08/2016 VISATRON Remote Indicator II For Oil Mist Detectors Operation Manual Part-No. 180050 VNxxx/87plus VNxxx/93 VNxxx/87-EMC VN115/87plus EX VN301plus (EX) Part-No. 150998 Page 2 of 20

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

Model A2100 Series Annunciator

Model A2100 Series Annunciator Seekirk Model A2100 Series Annunciator Applications: For usage within transformers, switchgear, breakers and/or within any processing equipment or control room applications either attended or unattended

More information

Analog Annunciator Unit SACO 16 A3. Product Guide

Analog Annunciator Unit SACO 16 A3. Product Guide Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Powerful, flexible and field-customizable 16-channel analog input signal annunciator unit A full

More information

AN-3100D Annunciator

AN-3100D Annunciator AN-3100D Annunciator FOR POWER GENERATION, TRANSMISSION & DISTRIBUTION, PETROLEUM, PETROCHEMICAL, AND OTHER PROCESS INDUSTRIES INNOVATIVE ANNUNCIATOR Continuing with the widely successful AN-3100 series

More information

M1000 Alarm Annunciator

M1000 Alarm Annunciator Data Sheet Alarm Annunciator Reliable Supervision and Control 10 inputs with LED indications Supports both NO/NC input contacts 10 open collector outputs Built-in siren relay Text label for alarm descriptions

More information

Fire control panels FC726 FC726-XA

Fire control panels FC726 FC726-XA Fire control panels FC726 FC726-XA Modular, pre-confectioned, microprocessor-controlled fire control panel for up to max. 1512 device addresses Integrated, user-friendly operating unit Detection and automatic

More information

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES Traffic sensors RELIABLE OVERHEIGHT DETECTION OF VEHICLES Reliable detection of vehicles in flowing, slow-moving

More information

Mosaic System-Control Room Technology. Illuminated Pushbutton and Pushbutton Switch LT 1879 / LT 2479 LS 1879 / LS 2479

Mosaic System-Control Room Technology. Illuminated Pushbutton and Pushbutton Switch LT 1879 / LT 2479 LS 1879 / LS 2479 Mosaic System-Control Room Technology Illuminated Pushbutton and Pushbutton Switch LT 1879 / LT 2479 LS 1879 / LS 2479 The products described in this brochure are intended for industrial use and meet the

More information

Model A1700 Series Annunciator

Model A1700 Series Annunciator Seekirk Model A1700 Series Annunciator Applications: For usage in all types of process industries, electric generation, transmission and distribution, gas and water utilities. Features: The Seekirk model

More information

RS485 MODBUS Module 8AI

RS485 MODBUS Module 8AI Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

System 57. An advanced World of intelligent gas detection system management

System 57. An advanced World of intelligent gas detection system management An advanced World of intelligent gas detection system management A World of control technology High precision, intelligent control Master / voted alarm options High packing density Flexible I/O configuration

More information

Complex alarming made simple

Complex alarming made simple SEL-2523 Annunciator Panel Complex alarming made simple Superbright LEDs provide easily visible alarm indication in any lighting condition. Sequential Events Recorder (SER) data help identify the root

More information

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r Type 2 safety light curtain FF-SLD Series FEATURES Active Optoelectronic Protective Device compliant with the requirements of the IEC/EN 61496-parts 1 and 2 European Norms 30 mm resolution for hand detection

More information

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Phone: 040 807-0 Fax: 040 807-259 Alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC display

More information

Installation Instructions

Installation Instructions Installation Instructions About This Document Use this document to install the 1784-PCM4/B cable. This cable connects the 1784-PCMK/B card to an SLC 5/01, 5/02, or 5/03 processor or a 1747-AIC link coupler

More information

On the job around the clock 24/7: Fire detection systems

On the job around the clock 24/7: Fire detection systems On the job around the clock 24/7: Fire detection systems Version 02.2010 Version: 02.2010 Product catalogue Fire detection systems This product catalogue is intended for sales purposes only. For planning,

More information

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933 Two-hand Safety Control Module FF-SR Series FEATURES Complies with the Machinery Directive 98/37/EC and UL 508 Type III C per EN 574, Category 4 per EN 954-1 Inputs for two dual-contact pushbuttons 0,5

More information

www. ElectricalPartManuals. com Annunciator unit Features Self-contained microprocessor-based annunciator unit with 64 alarm channels Application

www. ElectricalPartManuals. com Annunciator unit Features Self-contained microprocessor-based annunciator unit with 64 alarm channels Application Features Self-contained microprocessor-based annunciator unit with 64 alarm channels pplication larm channels activated by normally open or normally closed contact Small and large stand-alone annunciator

More information

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6 Page 1 of 6 Short profile Beckhoff Beckhoff implements open automation systems based on PC Control technology. The product range covers Industrial PCs, I/O and Fieldbus Components, Drive Technology and

More information

Parameterisable compact fault annunciator with permanent display

Parameterisable compact fault annunciator with permanent display Parameterisable compact fault annunciator with permanent display FSM 10 Drop-flap fault annunciator 31.08.2010 Permanent display even on power failure Compact module for 10 alarms Supply and alarm signal

More information

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with 8, 16, 24, 32, 40 and 48 signal inputs Status retention of inputs and sequence in case

More information

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers PRODUCT INFORMATION GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL In-situ Gas Analyzers MONITORING CARBON MONOXIDE EMISSIONS INNOVATIVELY AND EFFICIENTLY

More information

Accuracy counts! Sensors with analog output

Accuracy counts! Sensors with analog output Accuracy counts! Sensors with analog output Company Contrinex is a leading international high-tech sensor company with headquarters in Switzerland. Contrinex offers quality and highly innovative sensing

More information

System 57. An advanced world of intelligent gas detection system management

System 57. An advanced world of intelligent gas detection system management An advanced world of intelligent gas detection system management A world of control technology High precision, intelligent control Master/voted alarm options High packing density Flexible I/O configuration

More information

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor

More information

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS Product Information GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS Gas Analyzers SOLUTION FOR CONTINUOUS HYDROCARBON MEASUREMENTS The compact GMS800 FIDOR extractive

More information

PolyGard 2-channel Gas Controller MGC-03

PolyGard 2-channel Gas Controller MGC-03 PolyGard 2-channel Gas Controller MGC-03 DESCRIPTION Gas measuring and monitoring controller based on state-ofthe-art micro-technology with integrated buzzer for continuous monitoring of the ambient air

More information

Universal fault annunciator for panel mounting

Universal fault annunciator for panel mounting Universal fault annunciator for panel mounting Communication over Ethernet USM - Universal-fault annunciator for panel mounting Low depth housing for panel mounting Versions with 8, 16, 32 or 48 inputs

More information

Multi-Gas-Controller MGC2

Multi-Gas-Controller MGC2 Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants

More information

KNX The worldwide STANDARD for home and building control. KNX Association International

KNX The worldwide STANDARD for home and building control. KNX Association International KNX The worldwide STANDARD for home and building control KNX Association International KNX is the Standard CENELEC EN 50090 the only European Standard for Home and Building Electronic Systems (HBES) based

More information

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features. CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse

More information

BFD Light Curtains The new choice for cutting edge safety for industrial doors

BFD Light Curtains The new choice for cutting edge safety for industrial doors BFD Light Curtains The new choice for cutting edge safety for industrial doors The BFD Series light curtains are designed specifically for the industrial door market, as they provide a new safety sensor

More information

Annuciator Logic Controllers

Annuciator Logic Controllers C B0 C C5 C C6 C C7 A B A B A B A B A5 B5 A6 B6 A7 B7 A8 B8 A9 B9 5 Annuciator Logic Controllers 68 c5 c6 c7 B B B B B5 B6 B7 B8 B9 B0 B B B B B5 B6 C0 BUZZER RETURN BZ M / BZ CTROL SIGNAL LAMP DC() DC()

More information

STT 3000 Series STT250 /150 Surge Protection Device Specifications

STT 3000 Series STT250 /150 Surge Protection Device Specifications STT 3000 Series STT250 /150 Surge Protection Device Specifications Part Number: 46188660-501 EN2I-6061 June 2011 Introduction This device is designed to give the Smart Temperature Transmitter maximum protection

More information

KNX The worldwide STANDARD for home and building control. KNX Association International

KNX The worldwide STANDARD for home and building control. KNX Association International KNX The worldwide STANDARD for home and building control KNX Association International KNX is the Standard CENELEC EN 50090 the only European Standard for Home and Building Electronic Systems (HBES) based

More information

Pre-programmed room controller with communication

Pre-programmed room controller with communication revision 01 2011 RC-C Pre-programmed room controller with communication RC-C is a complete pre-programmed room controller from the Regio Midi series intended to control heating and cooling in a zone control

More information

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1 NGC-40 Bridge Overview Raychem-AR-H58862-NGC40BridgeOV-EN-1805 nvent.com 1 Table of Contents 1. NGC-40 Overview... 9 1.1 Example NGC-40 System... 10 2. Legal stuff... 11 3. Protocols... 12 3.1 Data es...

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE General Description This guide provides a summary for installing and configuring the Centaur TM Cube Slave Alarm Signalling Equipment

More information

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option SM3000 Videographic Recorder User Guide (RTU) Communications Option ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow

More information

Remote alarm indicator and test combination MK2430

Remote alarm indicator and test combination MK2430 Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Tel.: 040 807-0 Fax: 040 807-259 Remote alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC

More information

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with,,,, 0 and signal inputs Storage of the last state of inputs and sequence in the case

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min

More information

Window facia fault annunciators

Window facia fault annunciators Window facia fault annunciators WAP Window Annunciator Panel 15.08.2017 Annunciators for panel mounting with 24 signal inputs Storage of the last state of inputs and sequence in the case of power failure

More information

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 4/01 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1000 and UDC1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen PolyGard Single Point Controller SPC-X3-XX for Toxic Gases and Oxygen DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor and

More information

FC722 Fire control panel

FC722 Fire control panel FC722 Fire control panel Series FS720 (MPXS) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as

More information

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Process & TeMPerATUre UniversAl input DigiTAl MeTers Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min

More information

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder 1) Introduction The Appello tone and speech annunciation sounder has three different styles in AC and DC. A105NAPPX

More information

Fire control panels FC360

Fire control panels FC360 Cerberus TM FIT Fire control panels FC360 FC361-ZZ, FC361-ZA, FC361-YZ, FC361-YA Fire control panels (1-loop) for addressable peripheral devices with integrated operating unit One loop with 126 addresses

More information

SIL725 Safety Annunciator

SIL725 Safety Annunciator SIL725 Safety Annunciar Configurable SIL2 Annunciar certified IEC61508 SIRA certified at safety integrity level SIL2 IEC61508 Modular construction from 1 128 alarm channels Multi-redundant design Choice

More information

Technical Manual. Level Alarm Unit CARLA & WIDS

Technical Manual. Level Alarm Unit CARLA & WIDS CARLA & WIDS Technical Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Technical Manual CARLA for Tankers Cargo Tanks

More information

IntesisBox BACnet/IP Server - Notifier ID3000 series

IntesisBox BACnet/IP Server - Notifier ID3000 series IntesisBox Server - Notifier ID3000 series Gateway for integration of Notifier ID3000, ID3002, ID50 and ID60 fire panels into enabled control systems. Integrate your Notifier fire panels into your BACnet

More information

FC724 Fire control panel

FC724 Fire control panel FC724 Fire control panel Series FS720 (IP4) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 504 addresses Fire control panel can be used as

More information

FC724 Fire control panel

FC724 Fire control panel FC724 Fire control panel Series FS720 (IP5) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 504 addresses Fire control panel can be used as

More information

/8 DIN Level Indicator

/8 DIN Level Indicator Data Sheet SS/_6 High visibility 5-digit LED display clear and accurate indication Analog and relay outputs as standard high, low, latch and rate alarms, plus isolated retransmission Maths functions included

More information

CLEANROOM MONITOR CR3A Network - Installation Instructions

CLEANROOM MONITOR CR3A Network - Installation Instructions CLEANROOM MONITOR CR3A Network - Installation Instructions INTRODUCTION The CR3 Series Cleanroom Monitor, was developed specifically to allow for monitoring of confined spaces with accuracy and reliability.

More information

Labkotec Ice Detector

Labkotec Ice Detector Labkotec Ice Detector LID 3300IP Level and flow know-how since 1964 Benefits of using Ice Detector Stops wind turbine to prevent icethrow Safety first of all! Safety device Authorities / construction licence

More information

FC722 Fire control panel

FC722 Fire control panel FC722 Fire control panel Series FS720 (IP4) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as

More information

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements Specifications COMMANDER 150 Universal Process Indicator High visibility 6-digit LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement

More information

MO n : 12JMC rév A

MO n : 12JMC rév A CTT8 MO n : rév A Page 2 / 18 MODIFICATIONS Rev. Description Date Checked by Approuved by Z Creation 2012/02/12 JMC LA A First issue 2012/02/14 JMC LA INDEX Page 3 / 18 GENERALITY 4 INTRODUCTION 4 ACCESSORIES

More information

DiMM Unit. LST Digital Interface Monitor Module (LST-DiMM) MAN3109

DiMM Unit. LST Digital Interface Monitor Module (LST-DiMM) MAN3109 LST Digital Interface Monitor Module (LST-DiMM) MAN3109 TABLE OF CONTENTS: Page No. 1 Important Guidelines... 3 2 General Description... 4 Digital Interface Monitor Module... 4 3 Specifications... 5 Leader

More information

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2 Features Integrated (built-in NO2 sensor / detector (Electro chemical sensor type Measuring ranges 0-10 ppm, 0-20 ppm or 0-30 ppm LCD display to show actual in ppm Status LED indication Normal operation

More information

21-light Remote Annunciator. Owner s Manual

21-light Remote Annunciator. Owner s Manual 21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With

More information

HRX Technical Manual. Version 1.2

HRX Technical Manual. Version 1.2 HRX 5000 Technical Manual Version 1.2 Contents: Specification...2 Connectors...5 RS-485 Network Connectors (J6 and J7)...5 RS-232 to Printer (J19)...6 RS-232 to PC (J8)...7 TCP/IP...8 Power (J21)...9 Fire

More information

FC723 Fire control panel

FC723 Fire control panel FC723 Fire control panel FS720 series (IP5) Cerberus PRO Modular, prefabricated, microprocessor-controlled fire control panel with integrated user-friendly operating unit for up to max. 756 addresses Processes

More information

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers DFB Laser 8165xA Fabry-Perot Lasers Data Sheet Introduction The high power DFB Laser Source modules are best suited for optical amplifier test and DWDM system test applications. The Fabry-Perot Laser Sources

More information

Intelligent addressable fire alarm control panel

Intelligent addressable fire alarm control panel Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity

More information

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM 2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40

More information

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices. FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001

More information

CTT8 TEMPERATURE MONITOR DEVICE

CTT8 TEMPERATURE MONITOR DEVICE INSTRUCTION MANUAL IM302-U v2.3 CTT8 TEMPERATURE MONITOR DEVICE GENERALITY The device of control temperatures CTT8 is used in the control of electric machine, transformer, motor, etc. where it s possible

More information

XLH210: controller for gas leak detectors

XLH210: controller for gas leak detectors pag. 1 / 7 XLH210: controller for gas leak detectors Dixell introduces the new digital controllers designed to be combined with 4 20mA gas leak detectors. XLH210 is a microprocessor based controller, designed

More information

YOUR PARTNER IN FIRE & GAS DETECTION

YOUR PARTNER IN FIRE & GAS DETECTION YOUR PARTNER IN FIRE & GAS DETECTION OGGIONI s.a.s. Via Lavoratori Autobianchi, 1 - P.T.B. Edif.13/O - 20832 Desio (MB) Italy Tel.+39 0362 629135 Fax. +39 0362 622531 www.oggionisas.com - info@oggionisas.com

More information