Simple On The Outside...
|
|
- Joseph Dawson
- 5 years ago
- Views:
Transcription
1 Safer. Smarter. Tyco. Simple On The Outside...
2 ...Effective On The Inside Tyco Fire Protection Products is the leading manufacturer and distributor of water-based fire suppression systems and components, offering one of the broadest lines of fire protection system equipment worldwide. Continually expanding its capabilities through proactive research and product development, it providers its customers with effective fire protection and construction solutions for residential, commercial, industrial and institutional buildings. We supply a wide range of sprinklers, alarm valves and accessories as well as CPVC pipe & fittings, flowmeters, general purpose valves, hydrants, couplings and grooved fittings, sprinkler support materials, foam products and hardware. Tyco has branches strategically located throughout Europe and the Middle East to provide customers with the best possible service.
3 The Cabinets What makes it special? Easy to Install // Entire package is pre-wired // Water inlet and outlets to the valve riser are grooved to ensure minimal installation time // Completely pre-trimmed valve inside // Easy to move lift point eye bolts // Tested and fully functional Weather Proof // Available with optional heated housing // Applicable for indoor OR outdoor use // Comes complete with water resistant seal to project the entire contents of the cabinet Pre-tested // Tyco s cabinet system provides you with one complete solution with no need for any additional testing. The valves and components are all pre-tested by our Tyco engineers European Made // Uses the famous DV-5 which is produced in Spain // Designed, engineered and built at our Centre of Excellence for valve engineering in the Netherlands The TYCO DV-5 Red-E Cabinet, is a pre-assembled fire protection valve package enclosed within a free-standing cabinet designed to occupy minimal floor space and provide an enclosure for a fire protection valve riser. The packaged DV-5 Red-E Cabinet is pre-wired and the water inlet and outlets to the valve riser are grooved. The valve package includes the system (manual) shut-off control valve, a downstream shut-off valve, an automatic water control valve with electric actuation with galvanized trim and supervisory switches.
4 Options: Deluge Wet Deluge Dry Deluge Electric Heater Light and socket plug 230VAC Water motor alarm WMA Low temperature switch Manual pull station accessible from the outside Without downstream butterfly valve Cabinet colour grey RAL Potter Release Panel Handbook Factory acceptance test Split flanges (adapter grooved to flanged) Always refer to the Technical Data Sheet TFP1303 for complete description of all listing criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. LIFT POINT EYE BOLTS WATERFLOW PRESSURE ALARM SWITCH DRAIN DRAIN HEADER (CONNECTION EITHER SIDE OF CABINET) OPTIONAL RELEASING PANEL WITH LOCKING DOOR WATER SUPPLY HEADER (CONNECTION EITHER SIDE OF CABINET) CABINET (LOCKING DOORS NOT SHOWN) PRESSURE GAUGES DV-5 WITH ELECTRIC ACTUATION DELUGE TRIM DISCHARGE CONNECTION SOLENOID MANUAL STATION LEFT SIDE FRONT
5 How The Valve Functions All switches within the cabinet are pre-wired to a junction box. An optional control panel is available and is pre-wired. The control panel can be used to make the electrical connections for power, detection circuits, and alarms, the only remaining connections to complete the system. In addition to the optional control panel being integral to the DV-5 Red-E Cabinet, windows have been pro vided in the door for viewing the essential system pressure gauges. Locks for the cabinet door and the control panel access are standard. The outdoor version of the DV-5 Red-E Cabinet, Middle East have sealed doors and connections to the elements. Optimized Production Process Detailed Engineering Standard Cabinets Customer Sign off Standard Cabinets + options Special Cabinets Time scale By making use of optimized process Tyco is able to offer standardized cabinets and standardized cabinets with certain range of specific options. For these cabinets Detailed Engineering and Customer Sign Off can be done at the same time. This is enabled by an already prepared Detailed Engineering, availability of a Datasheet (TFP1303) and a quick quoting process. For Special Cabinets Tyco will follow the Detailed Engineering and Customer Sign Off as two separate steps. First the Detailed Engineering will be completed based on a discussion with the customer concerning his needs. Customer feedback on our designs is essential to ensure the exact needs of our customers are fulfilled. Based on this feedback and input from the customer, a quotation will be produced. We will only begin production when the customer is completely happy with the design and features of the cabinet.
Simple On The Outside...
Safer. Smarter. Tyco. Simple On The Outside... ...Effective On The Inside Tyco Fire Protection Products is the leading manufacturer and distributor of water-based fire suppression systems and components,
More informationWorldwide Contacts.
Worldwide Contacts www.tyco-fire.com DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package General Description The TYCO DV-5 Red-E Cabinet is a pre-assembled fire protection valve package enclosed
More informationTechnical Data. Working Pressure Range 20 to 250 psi (1,4 to 17,2 bar)
Worldwide Contacts www.tyco-fire.com DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package General Description The TYCO DV-5 Red-E Cabinet is a pre-assembled fire protection valve package enclosed
More informationDV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts
Worldwide Contacts www.tyco-fire.com DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package General Description The TYCO DV-5 Red-E Cabinet is a pre-assembled fire protection valve package enclosed
More informationDeluge & Preac tion Systems
Deluge & Preaction Systems Deluge Systems are normally used in special hazard installations where water must be applied to an entire area for protection. They use open sprinklers or spray nozzles attached
More informationTN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.
TN-25 Tunnel Fire Protection System Safer. Smarter. Tyco. Expert Fire Protection for Tunnels Tyco provides a complete fire protection solution to protect the infrastructure of tunnels. Whether it is rail,
More informationTechnical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:
Worldwide Contacts www.tyco-fire.com DV-5 Red-E Cabinet Integrated Preaction Fire Protection Package General Description The TYCO DV-5 Red-E Cabinet is a pre-assembled fire protection valve package enclosed
More informationTechnical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:
Worldwide Contacts www.tyco-fire.com DV-5 Red-E Cabinet Integrated Preaction Fire Protection Package General Description The TYCO DV-5 Red-E Cabinet is a pre-assembled fire protection valve package enclosed
More informationModel DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description
More informationTyco Fire Valves Pure Performance
Tyco Fire Valves Pure Performance Global Strength. Local Expertise. Tyco is a market leader in the $100 billion global fire protection and security solutions industries. Our 57,000 employees take great
More informationDIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses
PART 1 - GENERAL 1.1 SCOPE A. Through Class III Commodity Classification, up to 12.2m of single, double or multiple row rack storage, up to 14.6m building height (VanQuish Fire Sprinkler System). Cartoned
More informationPre-Pack INTEGRATED PRE-ACTION SYSTEM
Pre-Pack INTEGRATED PRE-ACTION SYSTEM HD FIRE PROTECT TECHNICAL DATA MODEL Pre-Pack SIZE DELUGE VALVE MODEL RISER CHECK VALVE MODEL WATER MOTOR GONG BELL MAXIMUM WORKING PRESSURE SYSTEM END CONNECTION
More informationADDITIONAL PRODUCTS 65
ADDITIONAL PRODUCTS 65 ADDITIONAL PRODUCTS Pictorial Table of Contents Model FastFlex Flexible Sprinkler Hose Page 67 Sprinkler & Valves Product Overview Page 72 Model UFBX Flexible Hoses Pages 68-69 Figure
More informationModel DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description
More informationTechnical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations
Worldwide Contacts www.tyco-fire.com AQUAMIST Mist Control Center (MCC) Pump Skid Unit General Description Center (MCC) Pump Skid Unit is a preassembled, self-contained, control center for Ultra Low Flow
More informationTechnical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations
Worldwide Contacts www.tyco-fire.com AQUAMIST Mist Control Center (MCC) Pump Skid Unit General Description Center (MCC) Pump Skid Unit is a preassembled, self-contained, control center for Ultra Low Flow
More informationModel CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950
Technical Services 00--9 +-0--0 www.tyco-fire.com Model CV-FR Riser Check Valves to Inch (DN0 to DN00) General Description The TYCO Model CV-FR Riser Check Valve is a compact and rugged swingtype unit
More informationFire Protection Products Technical Data Book Table of Contents, August 2017
Worldwide Contacts www.tyco-fire.com Fire Protection Products Technical Data Book Table of Contents, August 2017 SECTION 1 - STANDARD SPRAY SPRINKLERS DATE SHEET Series TY-L Pendent, Recessed Pendent,
More informationModel AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description
Worldwide Contacts www.tyco-fire.com Model AV--00 Alarm Valve With and Without Model RC- Retard Chamber European Conformity Valve Trim General Description The TYCO Model AV--00 Alarm Valves DN, DN0, DN0,
More informationA. This section includes design and performance information for fire protection and suppression systems.
SECTION 21 00 10: FIRE PROTECTION SYSTEM DESIGN 1. SUMMARY A. This section includes design and performance information for fire protection and suppression systems. 2. GENERAL A. All fire protection materials
More informationTotalPac 3 Firecyle III Deluge Remote controlled system
(Optional) DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of a Firecycle III system trim totally preassembled, pre-wired and factory tested. All electrical
More informationOwner/Operator Guide for Successful Sprinkler and Fire Pump Systems
Owner/Operator Guide for Successful Sprinkler and Fire Pump Systems Adam Olomon, P.E. Associate Consultant Fire & Life Safety and Fire Protection Introduction Adam Olomon Licensed Professional Engineer
More informationTotalPac 3 Wet pipe system c/w retard chamber
DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of an integrated wet type sprinkler riser assembly with retard chamber, totally pre-assembled, prewired and
More informationDatasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description
FIREFLEX VACTEC description This FIREFLEX VACTEC integrated fire protection system consists of a vacuum system trim totally pre-assembled, prewired and factory tested. All electrical and mechanical components
More informationDatasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description
FIREFLEX VACTEC description This FIREFLEX VACTEC integrated fire protection system consists of a vacuum system trim totally pre-assembled, prewired and factory tested. All electrical and mechanical components
More informationTotalPac 3 Double interlock Preaction, Electric/PneuLectric release Self-contained system
(Optional) DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of a preaction system trim totally preassembled, pre-wired and factory tested. All electrical
More informationTyco Fire & Building Products is available worldwide under the leading brand names: CENTRAL, GEM, STAR, and GRINNELL.
Tyco Fire & Building Products is a leading manufacturer and distributor of water-based fire suppression systems and components for special hazard risks, offering one of the broadest lines of fire protection
More informationTotalPac X Single interlock SUREFIRE system
DESCRIPTION This TOTALPAC X integrated fire protection system by FireFlex Systems Inc. consists of a trim totally preassembled, pre-wired and factory tested. All electrical and mechanical components of
More informationSINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH ELECTRIC RELEASE
SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH ELECTRIC RELEASE HD FIRE PROTECT TECHNICAL DATA SIZE DELUGE VALVE CHECK VALVE SPRINKLER ALARM RELEASE PANEL 50, 80, 100, 150 & 200 NB Model H3, UL Listed
More informationModel QRS Electronic Accelerator (Quick Opening Device) For Dry Pipe or Preaction Systems General Description
Technical Services: Tel: (800) 81-912 / Fax: (800) 91-00 Model QRS Electronic Accelerator (Quick Opening Device) For Dry Pipe or Preaction Systems General Description The Tyco Model QRS Electronic Accelerator
More informationTotalPac X Firecycle III Preaction Double interlock system
DESCRIPTION This TOTALPAC X integrated fire protection system by FireFlex Systems Inc. consists of a multicycling Firecycle III system trim totally pre-assembled, pre-wired and factory tested. All electrical
More informationAQUAMIST Mist Control Center (MCC) Pump Skid Unit. General Description. Technical Data. Page 1 of 8 JANUARY 2016 TFP2270. Worldwide Contacts
Worldwide Contacts www.tyco-fire.com AQUAMIST Mist Control Center (MCC) Pump Skid Unit General Description Center (MCC) Pump Skid Unit is a preassembled, self-contained, control center for the Ultra Low
More informationN2 BLAST Datasheet Preaction double interlock, Electric/Pneumatic c/w N 2 Blast Nitrogen generating system Self contained unit
FireFlex N 2 Blast description The FIREFLEX N2 Blast integrated system consists of an integrated double interlock Electric/Pneumatic release preaction automatic sprinkler system combined with a Nitrogen
More informationSprinkler Inspection Certificate
Sprinkler Inspection Certificate For New Dimensions High School 4900 Old Pleasant Hilll Road Kissimmee, FL 34746 Tested to NFPA 25 Standards This Inspection was performed in accordance with applicable
More informationDOUBLE INTERLOCK, PREACTION SYSTEM WITH ELECTRIC/PNEUMATIC RELEASE
DOUBLE INTERLOCK, PREACTION SYSTEM WITH ELECTRIC/PNEUMATIC RELEASE HD FIRE PROTECT TECHNICAL DATA SIZE DELUGE VALVE CHECK VALVE SPRINKLER ALARM RELEASE PANEL 50, 80, 100, 150 & 200 NB Model H3, UL Listed
More informationSINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH WET PILOT ACTUATION
SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH WET PILOT ACTUATION HD FIRE PROTECT TECHNICAL DATA SIZE DELUGE VALVE CHECK VALVE SPRINKLER ALARM RELEASE PANEL 50, 80, 100, 150 & 200 NB Model H3, UL
More informationas required for residential sprinklers intended for use in dry pipe systems.
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Residential Dry Pipe System General Description The TYCO RAPID RESPONSE Residential Dry Pipe System provides a normally dry system for areas subject
More informationInstructions for Installation, Operation, Care and Maintenance
Instructions for Installation, Operation, Care and Maintenance Bulletin 733 Rev. F Model DDX PrePaK, Type D Preaction System 4 (100mm), 6 (150mm) & 8 (200mm) Single Interlock - Electric Release Double
More informationPHYSICAL FACILITIES. 1 General. 2 Related Requirements. 5 Quality Assurance. 3 Wiring. 4 Submittals
1 General 1.1 Provide all material, labor, engineering and operations for the installation of complete and operable fire suppression systems as shown in the job scope and as specified herein. 1.2 Provide
More informationTotalPac 3 Single interlock Firecyle III Preaction Self-contained system
(Optional) DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of a Firecycle III system trim totally preassembled, pre-wired and factory tested. All electrical
More informationDIVISION 21 - FIRE SUPPRESSION
DIVISION 21 - FIRE SUPPRESSION DESIGN CRITERIA It is the policy of UC Davis to install fire sprinkler systems in all new construction/facilities. If the building is classified as a pole barn, shed, carport,
More informationPRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM
ANNEXUREIII D: FIRE PROTECTION SYSTEM SECTION ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM Supply, Installation, testing and commissioning of Analogue Addressable Fire Alarm Control panel with battery backup
More informationVIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description
Worldwide Contacts www.tyco-fire.com VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description The TYCO VIZOR Electronic Dry Pipe Accelerator (EDPA) is
More informationDIVISION 21 - FIRE SUPPRESSION
DIVISION 21 - FIRE SUPPRESSION DESIGN CRITERIA It is the policy of UC Davis to install fire sprinkler systems in all new construction/facilities. If the building is classified as a pole barn, shed, carport,
More informationN2 BLAST Datasheet SUREFIRE double interlock c/w N 2 Blast Nitrogen generating system Self contained unit
SUREFIRE double interlock c/w N 2 Blast Nitrogen generating system FireFlex N 2 Blast description The FIREFLEX N2 Blast integrated system consists of an integrated SUREFIRE double interlock preaction automatic
More informationSprinkler Solutions for Storage Applications
Sprinkler Solutions for Storage Applications Logistics and Distribution As storage facilities and their distribution methods have evolved, so have the challenges of protecting them. When installing a fire
More informationDELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82 ASTM A 216 WBC.
DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA NORMAL SIZE MATERIAL SEVICE PRESSURE THREADED OPENING MOUNTING FACTORY HYDOSTATIC TEST PRESSURE FLANGE CONNECTION WET PILOT SPRINKLER HEIGHT LIMITATION NET WEIGHT
More informationResidential Fire Protection Sprinklers & Systems
Residential Fire Protection Sprinklers & Systems Product Guide LFII Residential Sprinklers Sprinkler System Components CPVC Pipe & Fittings Specific Application Attic Sprinklers LFP Antifreeze for Fire
More informationNot to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT
Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT Project No: 3049157 Class: 1011/1012/1013 Product Type: Deluge and Preaction Sprinkler Systems Product
More informationN2 BLAST Datasheet Preaction double interlock, Electric/Pneulectric c/w N 2 Blast Nitrogen generating system Self contained unit
Preaction double interlock, Electric/Pneulectric c/w N 2 Blast Nitrogen generating system FireFlex N 2 Blast description The FIREFLEX N2 Blast integrated system consists of an integrated double interlock
More informationUC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS
DIVISION 21 - FIRE SUPPRESSION Includes the following sections: None DESIGN REQUIREMENTS It is the policy of City of Santa Cruz to install fire sprinkler systems in all new construction/facilities. If
More informationModel CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts
Worldwide Contacts www.tyco-fire.com Model CV-F Grooved End Swing Check Valves General Description The TYCO Model CV-F Grooved End Swing Check Valves are compact and rugged swing-type units that allow
More informationCubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM
SECTION 21 0000 AUTOMATIC FIRE SPRINKLER SYSTEM PART 1 GENERAL 1.1 QUALITY ASSURANCE A. Codes and Standards: 1. FBC (Florida Building Code 2015) 2. FBC (Florida Fire Code 2015) 3. NFPA #13R (Standard for
More informationWET-PIPE SPRINKLER SYSTEMS
SECTION 211313 - WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipes, fittings, and specialties. 2. Fire-protection valves. 3. Fire-department connections. 4. Sprinklers.
More informationGas Station & C Store SECTION CWM Job No
SECTION 21 1300 - PART 1 - GENERAL 1.1 WORK INCLUDED A. Provide labor, materials, equipment and services to perform operations required for the complete installation and related Work as required in Contract
More informationCare and Maintenance
Worldwide Contacts www.tycofire.com GRINNELL GFIRE Figure 71 Flange Adapters 2 to 12 Inch (DN50 to DN300) General Description The GRINNELL GFIRE Figure 71 Flange Adapters allow a direct transition from
More informationAESTHETIC SPRINKLERS.
AESTHETIC SPRINKLERS. B L E N D I N B E A U T I F U L LY. DESIGN UNCOMPROMISED. You have a specific vision for your building. Our sprinklers won t disrupt it. RAVEN Studio and Flat Plate Concealed sprinklers
More informationRAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description The TYCO RAPID RESPONSE Model RCP-1 Residential
More informationB. The sprinkler system shall be designed to meet the more stringent of the requirements of NFPA 13 and FM Global requirements.
SECTION 21 13 13 FIRE PROTECTION SPRINKLER SYSTEMS PART 1 - GENERAL 1.01 SUMMARY A. Section includes labor and materials for the installation of a hydraulically calculated automatic, wet-pipe sprinkler
More informationWest District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8
City of Ottawa Project No. CR006230 Page 1 of 8 PART 1 - GENERAL 1.1 Reference Standards.1 Conform to the following:.1 Provincial and municipal building and fire regulations as approved by Provincial Fire
More informationANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual
ANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual 001799 This manual is intended for use with the ANSUL AUTOMAN Il-C Explosion-Proof Releasing Device.
More informationConnected: Global protection, all together
Connected: Global protection, all together Connecting with customers like no others. Keeping people, property and your environment safe is the objective. And no one is equipped to help you reach it as
More informationSPRINKLERS TABLE OF CONTENTS
SPRINKLERS TABLE OF CONTENTS SECTION 21 13 13 WET PIPE SPRINKLER SYSTEMS SECTION 211313 - WET PIPE SPRINKLER SYSTEMS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract,
More informationVSR-M REPLACEMENT Waterflow Switch for Globe Sprinkler Model UMC Manifold
Features NEMA 4 solid metal enclosure Factory installed neoprene gasket 0-90 second field replaceable pneumatic retard 350 PSI system pressure rated Synchronized switch action Waterflow switches that are
More information2. Welding Materials and Procedures shall conform to the ASME Code.
PART 1 GENERAL 1.01 Scope of Standard A. The design guidelines contained herein include the requirements for systems, materials, fittings and valves utilized for fire protection systems at Sam Houston
More informationPERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D40 FIRE PROTECTION 02/18
NAVFAC PTS-D40 (February 2018) -------------------------------- Preparing Activity: NAVFAC SUPERSEDING PTS-D40 (September 2016) PERFORMANCE TECHNICAL SPECIFICATION SECTION D40 FIRE PROTECTION 02/18 NOTE:
More informationRapidrop Global Ltd. Product Range. British Manufacturer and Supplier of Fire Sprinkler and Fire Suppression Equipment.
Rapidrop Global Ltd British Manufacturer and Supplier of Fire Sprinkler and Fire Suppression Equipment Product Range About Rapidrop About Rapidrop Global Limited is the leading UK manufacturer of fire
More informationRAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) SECTIONS General Description.... 1 Warnings.... 2 Technical
More informationFireFlex DUAL Double Interlock, Self-contained system
FireFlex DUAL description The FireFlex DUAL integrated system consists of an integrated Double interlock preaction automatic sprinkler system combined with a clean agent fire extinguishing system, factory-assembled
More informationTECHNICAL DATA OBSOLETE
January 27, 2012 311a 1. DEsCrIpTIoN (Refer to Figures 1-3.) Viking supervised Single Interlocked Preaction Systems utilize a Viking Deluge Valve and a pneumatically pressurized automatic sprinkler system.
More informationTECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE
Page 1 of 12 1. DESCRIPTION (Refer to Figures 1-6.) Viking Electric/Pneu-Lectric Double Interlocked Preaction Systems utilize a Viking deluge valve, pneumatic supervision of the automatic sprinkler system,
More informationTechnical Data. Sizes: ANSI Inches (DN) 2-1/2 (DN65), 3 (DN80), 4 (DN100), 5 (DN125), 6 (DN150), 8 (DN200), 10 (DN250)
Worldwide Contacts www.tyco-fire.com Model BFV-/BFV-C Butterfly Grooved End General Description The TYCO Models BFV- (Normally Open) and BFV-C (Normally Closed) Grooved End Butterfly s are indicating type
More informationSECTION PREACTION SPRINKLER SYSTEMS
PART 1 GENERAL SECTION 211316 - PREACTION SPRINKLER SYSTEMS 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More information1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:
SECTION 21 10 00 - WATER-BASED FIRE-SUPPRESSION PART I - GENERAL 1.1 SUMMARY A. Inclusion of sprinkler and standpipe systems shall be as determined by NFPA National Fire Code pamphlet 101 and program statement.
More informationTOTALPAC2 Integrated Fire Protection System
TOTALPAC2 Integrated Fire Protection System Page 1 of 8 General 1. Applicable Standards The TOTALPAC2 Surefire complies with the following standards: - NFPA-13 Sprinkler Systems; - NFPA-15 Water Spray
More informationB. Standard-Pressure Standpipe Piping: Fire-suppression standpipe piping designed to operate at working pressure 175 psig (1200 kpa) maximum.
Page 211200-1 SECTION 211200 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationRevision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.
SECTION 211300 FIRE SUPPRESSION SYSTEMS 1.0 All new and renovated buildings shall be provided with automatic sprinklers throughout and fire standpipe systems. The design and installation of these systems
More informationTotalPac 3 Deluge, Electric release Self-contained system
(Optional) DESRIPTION This TOTALPA 3 integrated fire protection system by FireFlex Systems Inc. consists of a deluge system trim totally preassembled, pre-wired and factory tested. All electrical and mechanical
More informationTHE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION
SECTION 21 1301- FIRE-SUPPRESSION SYSTEMS PART 1 - GENERAL 1.1 SUMMARY: A. This Section includes fire-suppression piping and equipment for the following building systems: 1. Wet-pipe, fire-suppression
More informationTECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE
Page 1 of 12 1. (Refer to Figures 1-7.) Viking supervised Single-Interlocked Preaction Systems utilize a Viking Deluge Valve and a pneumatically pressurized automatic sprinkler system. The system piping
More informationNorth Hanover Township School District North Hanover Township, New Jersey
SECTION 211313 - WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipes, fittings, and specialties. 2. Fire-protection valves. 3. Fire-department connections. 4. Sprinklers.
More informationInstructions for. Care and Maintenance 10 psi (0,7 bar) Pneumatic Supervising Pressure. Single Interlock
Bulletin 740 Rev. A Model DDX PrePaK, Type D Preaction System 2 (50mm), 2-1/2" (65mm) & 3 (80mm) Sizes Instructions for Single Interlock Installation, Operation, Double Interlock Care and Maintenance 10
More informationSECTION AUTOMATIC SPRINKLER PIPING
SECTION 15330 AUTOMATIC SPRINKLER PIPING ****** ***** **** *** ** * ** *** **** ***** ****** NOTE TO SPECIFIER: This section contains several types of automatic sprinkler piping. Some piping is allowed
More informationTechnical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved
Worldwide Contacts www.tyco-fire.com Model TJR Resilient-Seated Gate Valves Outside Screw and Yoke General Description TYCO Model TJR Resilient-Seated Gate Valves are used in Fire Protection Systems for
More informationTECHNICAL DATA 1. SYSTEM DESCRIPTION 2. SYSTEM OPERATION 3. INSTALLATION. Page 1 of 5
Page 1 of 5 1. SYSTEM DESCRIPTION Viking supervised, single interlocked preaction pre-primed systems utilize a Viking Deluge Valve (A.1) and a hydraulically pressurized automatic sprinkler system. The
More informationB. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.
DIVISION 21 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, sleeves, escutcheons, seals, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS
More informationGravity and Pneumatic Waste and Linen Handling Systems NFPA 82 Inspection Form
Gravity and Pneumatic Waste and Linen Handling Systems NFPA 82 Inspection Form PART 1 GRAVITY CHUTES CHUTE DESIGN AND INSTALLATION INTAKE OPENINGS LIMITED ACCESS OFFSETS DIMENSIONS VENTING CONSTRUCTION
More informationTECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.
Page 1 of 9 1. (Refer to Figures 1-3.) Viking Electric/Pneumatic Double Interlocked Preaction Systems utilize a Viking deluge valve controlled by a pneumatic actuator (E.1), normally held closed by supervisory
More informationFIRE-PAC SERIES 745 FIRELOCK SYSTEMS
FIRE-PAC SERIES 745 FIRELOCK SYSTEMS DRY DELUGE PREACTION COMPACT, SIMPLIFIED SOLUTIONS PB-403 REV C FireLock Series 745 Fire-Pac Systems 1½ 8" 40 200 mm Included in the FireLock Fire-Pac are a water supply
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 21 1314D - AUTOMATIC SPRINKLER SYSTEMS (DRY-PIPE) PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationEnvironmental Health & Safety
Environmental Health & Safety Oklahoma State University FIRE SPRINKLER SYSTEM STANDARD Environmental Health and Safety University Health Services Suite 002 Stillwater, OK 74078 (405) 744-7241 www.ehs.okstate.edu
More informationDesign & Construction Standards, Revised January
PART 1 GENERAL 1.01 Scope of Standard A. This standard provides general requirements of The University of Texas at Austin for fire-extinguishing systems other than water-based fire suppression systems.
More informationAnnual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System
Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System Building/Business Name: Address of Property: Inspector Name: Joe Price THE CORNERSTONE 1425 NE 7TH AVENUE PORTLAND OR Date
More informationALEWIJNSE INTERNATIONAL SWITCHBOARD PRODUCTION
ALEWIJNSE INTERNATIONAL SWITCHBOARD PRODUCTION www.alewijnse.com Empowering your business INTRODUCTION A lewijnse International Switchboard Production (AISP) designs and assembles distribution switchboards,
More informationADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri
ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1 TO CONTRACT DOCUMENTS ENTITLED: PROJECT MANUAL FOR: Women s and Children s Hospital New Water Service Main PROJECT NUMBER: CP172631 ADVERTISEMENT DATE: July
More informationEffective Date 3/13/2007 With Addendums thru 12/5/2007
3/13/2007 With Addendums thru 12/5/2007 Supersedes Price Book 5/22/2006 and Addendums U. S. List Prices for Sprinklers, Devices, Grooved Piping, CPVC, Accessories and Repair Parts Price Book Price Book
More informationOPEN SPRINKLER SYSTEM
OPEN SPRINKLER SYSTEM Introduction Competence and innovation driven by consistent market development and customer requirements have shaped the successful development of the SHIELD Brand. The extensive
More informationA. Standard-Pressure Piping System Component: Listed for 175-psig minimum working pressure.
SECTION 211313 - WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipes, fittings, and specialties. 2. Fire-protection valves. 3. Fire-department connections. 4. Sprinklers.
More informationTECHNICAL DATA. 319a. January 27, 2012
January 27, 2012 319a 1. DEsCrIpTIoN (Refer to Figures 1-3.) Viking Electric/Pneumatic Double Interlocked Preaction Systems utilize a Viking deluge valve controlled by a pneumatic actuator (E.1), normally
More informationTechnical Instructions Document No P25 ET September 28, ET 141 Electric Surface Mounted Thermostat.
Document No. 155-018P25 ET 141-1 ET 141 Electric Surface Mounted Thermostat Description This electric surface mounted thermostat has a Single-Pole, Double-Throw (SPDT) contact mechanism and is designed
More information