with internal sensor (channel 1) with an external sensor (channel 2) A-Editor software, Professional AK20 version (not for version AK4)

Size: px
Start display at page:

Download "with internal sensor (channel 1) with an external sensor (channel 2) A-Editor software, Professional AK20 version (not for version AK4)"

Transcription

1 Examples of use Example Creating an SMS-based alarm with confirmation A project file must first be created using the A-Editor software. This project file is then stored in the alarm modem. The alarm modem is thus configured and functional. Measuring instrument: Contact Alarm goes to SMS Alarm: Alarm text Data logger 77 T (temperature) with internal sensor (channel ) with an external sensor (channel ) A-Editor software, Professional AK0 version (not for version AK) Technician 0-7 (mobile no. of technician) An alarm is to be sent when the external sensor reaches > C. Only the internal alarm from the logger is to be forwarded by the alarm modem, i.e. the logger is not to be permanently monitored by the alarm modem. Advantage: The logger battery is preserved. If the alarm is not confirmed within minutes, the same alarm is sent again. The technician confirms the alarm: he responds to the SMS received by sending the original text (containing the confirmation code) back to the alarm modem word for word. Alarm! Channel : "channel reading" > C. "Confirmation Code". "Date + Time" A) Requirements - The data logger must be programmed so that: - Alarm on logger is not set to on, i.e. red LED flashing - The upper alarm threshold of channel is set to C - All other alarm thresholds are well out of range - The required measuring cycle is set. - The A-Editor software is installed on the PC. B) Cabling The logger is linked to the alarm modem (COM) by means of the serial interface cable. For programming the alarm modem (COM), this is connected to the PC by means of the serial interface, but only while the project file is being created and saved. (See Chapter. Setting up alarm modem) C) Programming the alarm modem using the A-Editor: Start A-Editor software and access the project file containing the configuration of the alarm modem by doing one of the following: a) Load from the alarm modem; b) Load from PC; c) Create from new (refer to example in "Commissioning"). For this, the modules in the software must be processed as follows: Page

2 . Project module The project file contains all of the configuration data for operation and the requisite functions of the alarm modem. The options for creating the project file are as follows: - Use existing project file from the alarm modem as a template and modify accordingly: -> "Read Project" (see options bar on the left-hand side) For this, the alarm modem must be connected to the PC. Only then is the function shown. For activating the connection, refer to next chapter, "Connection module". - Use existing project file from the PC memory as a template and modify accordingly: -> "Load..." (options bar on left-hand side) I - Create a completely new project file: -> Select "New Project from Template" II Note: To set up a new project file, which requires considerably more information to be input than can be explained here, please refer to example in "Commissioning" or the Instruction manual. I II Page

3 . Connection module Create connection to alarm modem in A-Editor, i.e. select first, then connect: Imperative: The alarm modem must by this point be connected to the PC by means of the serial interface cable. In the first window, select "New" in the options bar on the left hand side, whereupon the new window will appear: 7 Connection Name Enter name for the connection. Location Enter location. No relevance to the messages. Type Select type of connection required. In the example, the project file is to be saved from the PC to the alarm modem, locally by means of a cable. Advanced Opens the details for "Local Modem". Find modems Click on here. The connected modem is identified, provided that the correct cabling is installed. Authentication A password can be stored in the project file as a means of access protection (in Alarm Modem Module). If a project file with this kind of access protection is used, e.g. is already saved in the alarm modem, the password must be given at this point to gain access to the alarm modem. This is not the password for remote switching which has to be given in the SMS text. Connect 7 Click on here and create the connection. Page

4 . Alarm Modem module The basic data about the SIM card and providers are stored here. If an existing project has been loaded, no changes are required at this point in order to carry out the "Alarm" function described in this example. The above data only have to be entered when creating a completely new project file. However, this is discussed in a separate section; please refer to the example given in one of the following: Commissioning or the Instruction manual. Page

5 . Variables module Variables Autodetect The A-Editor identifies all variables with the units which are available for the measuring instrument connected. Apart from this, the current values/readings are read in.the variables also include the readings for the individual channels, including the unit. In the example: ch# C (channel ) ch# C (channel ) Read Variables The values of the individual variables are read out of the alarm modem, i.e. they are not the measurement values from the measuring instrument itself, but the values which were read out from the measuring instrument into the alarm modem during the last Autodetect. For the purposes of further programming, it is advisable, or even necessary, that all variables available from the measuring instrument have been detected. To this end the variables must be scanned with "Autodetect"! This assumes that the instruments have been wired correctly and a connection has been activated in the "Connection" module. The command "Read Variables" will only provide correct values/units if the project has previously been sent to the alarm modem with the correctly scanned variables. How to send the project is described later under point 8. Page

6 . Address Book module 7 Address Book module In the first window: On the left-hand side in the Options menu: click on "New Contact". Name Name of contact Not necessary, as the alarm message should only be transmitted via SMS. Express To be left empty, function not activated SMS number Enter the mobile number of the contact address Pager number To be left empty, function not activated Fax Number Not necessary, as the alarm message should only be transmitted via SMS. OK 7 Finish and save the new contact. Page

7 . Messages module Messages module In the first window: On the left-hand side in the Options menu: Click on "New Message" or modify existing message by double-clicking on it. Name of Message Title for the message Message Type Choose appropriate message type, "SMS" in this case. Message Text Enter the message text: The variables - "ch# C" (current reading for channel ) A randomly generated code is sent to the recipient of the alarm in the alarm SMS. This code must be sent back to the alarm modem via SMS within the confirmation timeframe (definable), otherwise another alarm will be sent. - "Confirmation Code" - "Date + Time" are selected with the help of the Contact menu. Do this by rightclicking on the appropriate part of the text and selecting the relevant variable via the menu structure; in the case of the channel reading for example: -> testo 7/77 ->Inputs -> ch# C Append Location Text If the location text (as shown in the preview) is to be attached to the SMS, please activate the box. Remaining Characters Displays the remaining number of characters for the SMS. No further information can be sent by SMS. OK Finish and save the message. Page 7

8 7. Alarms module Example alarms have already been created in the list of alarms and are activated. Those alarms which you yourself are not using or modifying should be deactivated. Do this by going into each individual alarm and declicking the "Activated" box. As the internal alarm of the data logger is used as a trigger, the following must be observed: When programming the data logger, the following settings must be made in the ComSoft -> Instrument control -> Settings: Ativate Alarm Switch Output. Alarms module In the first window: On the left-hand side in the Options menu: Click on "New Alarm" or modify existing alarm by double-clicking on it. Name Name of alarm Event "Threshold Overshooting" must be selected in order to forward the internal alarm of the data logger. This option is recommended for data loggers, because the alarm modem does not wake the measuring instruments according to the rhythm of the querying rate, but only reacts to their alarm output. The querying rate can thus be h (factory setting). This considerably increases the battery life of Page 8

9 the data logger. However, when the internal alarm in the data logger switches to on, and the corresponding variable assumes the value accordingly, the querying rate automatically changes to 0 sec. The.original querying rate switches back to the original condition only when the alarm in the data logger is reset to 0 (via SMS switch command, with the Alarm Editor or by reprogramming the data logger). Variable The internal alarm of the data logger must be chosen here as the variable: "testo 7/77-Alarm" Trigger To access the alarm condition (data logger alarm from 0 to, corresponding to reading > C), "Low to High" must be chosen. Activated Activate alarm Contact Choose "Technician" and the message type: "SMS" Message 7 Select "Example Alarm" Following Alarm 8 Select "(Retry)". The same alarm text is thus sent again to the same destination. "Create New Alarm is also an option. The content and destination can both be reset in the new alarm. Confirmation 9 Activate Confirmation Timeframe 0 Set to " Minutes". OK Save alarm with "OK". Test Alarm In the options bar on the left-hand side of the screen. The alarm is triggered for testing using this switch. This checks that the alarm has been transmitted correctly, including with the requisite content. Testing the alarm this way is recommended before putting the system into service. Page 9

10 8. Project module Project module Save As... It is a good idea to save the project file to the PC under a name first before loading it into the alarm modem. Send Project Load the project file into the alarm modem. The alarm modem is now fully configured or programmed. The cabling between the alarm modem and PC can be disconnected and the system (consisting of the alarm modem and measuring instrument) can be left to operate. Exit the A-Editor. Page 0

Sentient. Downloader Manual D4854

Sentient. Downloader Manual D4854 Sentient Downloader Manual D4854 Dycon Ltd Tel: +44 (0)1443 471 060 Fax: +44 (0)1443 479 374 Cwm Cynon Business Park Mountain Ash CF45 4ER - UK www.dyconsecurity.com sales@dyconsecurity.com TABLE OF CONTENTS

More information

FCD-wire Contents. List of Figures

FCD-wire Contents. List of Figures FCD-wire Contents FCD-X21 Configuration 1 Introduction... 1 2 Opening the FCD Application... 1 3 FCD Window... 2 4 FCD LEDs... 3 5 Configuration Operations... 4 FCD Info...4 FCD System Info...5 FCD Interface

More information

Alarm handling by SMS in ALERT

Alarm handling by SMS in ALERT Micromedia International Alarm handling by SMS Author: Jens Eberle Pages : 9 Company: Micromedia International Date : 29/10/2013 Version : 1.1 Réf. : Alarm Handling by SMS.docx [Commentaires ] Alarm handling

More information

Other trade names mentioned in this document may be registered trademarks or trademarks of respective product manufacturers or vendor products.

Other trade names mentioned in this document may be registered trademarks or trademarks of respective product manufacturers or vendor products. Attention! Read this user manual carefully. Representative of the company installing the alarm system will explain which security module SP231 functions needs to be activated to ensure proper security

More information

Internet enabled RTU/Data loggers. ilog-gsm/edm: Tutorial Vers /2.0 August 2006

Internet enabled RTU/Data loggers. ilog-gsm/edm: Tutorial Vers /2.0 August 2006 ilog s ilog-gsm/edm: Tutorial Vers. 1.2-3.4/2.0 August 2006 1. Introduction ilog is a new generation digital RTU/data logger incorporating full Internet capabilities. This step by step tutorial intends

More information

rvm4c Installation Guide Remote Video Module

rvm4c Installation Guide Remote Video Module rvm4c EN Installation Guide Remote Video Module rvm4c Installation Guide Installation Diagrams EN 2 Installation Diagrams for the Transmitting Unit rvm4c Installation Guide Basic Hardware Installation

More information

IRIS Touch Firmware Enhancements and Additions from Version to Version

IRIS Touch Firmware Enhancements and Additions from Version to Version Overview IRIS Touch Firmware Enhancements and Additions from Version 1.14.3 to Version 1.19.1 This document details enhancements to the feature set of the IRIS Touch from firmware Version 1.14.3 to Version

More information

WiFi Hints & Tips. Contents. WiFi Hints and Tips 1. Page No. Section No. Title

WiFi Hints & Tips. Contents. WiFi Hints and Tips 1. Page No. Section No. Title WiFi Hints & Tips Contents Page No. Section No. Title Section.0 System Set-Up 3 Section. Sensor Set-Up 4-5 Section. Sensor Set-Up (Configuring Network) 6-9 Section.3 Sensor Set-Up (Configuring Settings)

More information

SCAN200E USER S MANUAL

SCAN200E USER S MANUAL SCAN200E USER S MANUAL Code No. 2071 1052 rev. 1.4 Code No. 2071 1052 Rev. 1.4 Page 2/16 SCAN200E User s Manual Foreword This manual is for SCAN200E Controller running software version 2.03 or later. We

More information

CONTENT version Piccolo Object protection

CONTENT version Piccolo Object protection CONTENT version 1.14 1: PICCOLO - WIRELESS PROTECTION... 4 HOW THE PICCOLO SYSTEM WORKS... 4 SYSTEM DESCRIPTION... 4 DETECTORS... 4 ALARM RECEIVERS... 4 CENTRAL UNIT & PC... 4 FORWARDING ALARMS (INTERFACES)...

More information

SC-F3G User Manual 1.0

SC-F3G User Manual 1.0 SC-F3G User Manual 1.0 Table of Contents 1. Introduction... 3 2. Functions... 3 3. Features... 3 4. Package Contents... 3 5. Device Configuration... 4 6. Status LED signals... 5 7. Before You Start...

More information

SCAN20 Series Gas Detection Controller

SCAN20 Series Gas Detection Controller SCAN20 Series Gas Detection Controller USER S MANUAL Code Number 2071 1022 SCAN20 USER S MANUAL Code no. 2071 1022 Page 1/14 Foreword This manual is made for SCAN20 Controllers equipped with the software

More information

GLOBAL. InstallatIon & operation manual

GLOBAL. InstallatIon & operation manual InstallatIon & operation manual INDEX 1. INTRODUCTION... 5 2. FEATURES AND FUNCTIONS 2.1 Reporting Options... 2.2 Interfaces... 2.3 Programming... 2.4 Indicators and Controls...... 6 6 6 6 6 3. INSTALLATION...

More information

Fire Control Panel FS5100

Fire Control Panel FS5100 Fire Control Panel FS5100 INSTRUCTION MANUAL Revision 6/02.11 Contents 1. Introduction... 5 2. Terminology... 5 3. Function... 7 4. Technical data... 7 4.1. Modules... 7 4.1.1. Type of modules... 7 4.1.2.

More information

1. User features of the GSM dialer

1. User features of the GSM dialer 1. User features of the GSM dialer The JA60GSM dialer offers many useful features described in detail below. The installer should properly demonstrate the use of the system to the user after installation

More information

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Revision 6/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

D3D Wi-Fi GSM Smart Alarm System -User Manual

D3D Wi-Fi GSM Smart Alarm System -User Manual D3D Wi-Fi GSM Smart Alarm System -User Manual D3D Wi-Fi / GSM Smart Alarm system (Model : D10). Please read all instructions carefully & follow steps for easy home installation. 1 P a g e D3D Wi-Fi / GSM

More information

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document 70072-0125-01 TECHNICAL NOTE NOVEMBER 2006 ION Meter Alerts A PowerLogic ION meter can send alerts to indicate a user specified power system condition such as a power quality problem (including surges,

More information

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63 Fire Extinguishing Control Panel FS5200Е INSTRUCTION MANUAL Revision 8/01.17 Instruction Manual Page 1 1. 2. 3. 4. 4.1. 4.2. 4.2.1. 4.2.2. 4.2.3. 4.2.4. 4.2.5. 4.2.6. 4.2.7. 4.2.8. 4.2.9. 4.2.10. 4.2.11.

More information

Contents. Glossary

Contents. Glossary Contents Glossary ------------------------------------------------------------------------------------------------------ 6 1. Introduction to the IDS 1632 -------------------------------------------------------------

More information

SMS GSM Alarm Messenger

SMS GSM Alarm Messenger SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up

More information

SA 2650 Kit User Manual

SA 2650 Kit User Manual SA 2650 Kit User Manual Table of Contents 1. System Installation Planning 1 2. Device Introduction 3 3. Getting Started 6 4. System Default Setting 10 5. Connect2Home Application 11 6. System Information

More information

DESCRIPTION OF KEYPAD (Access module with segments)

DESCRIPTION OF KEYPAD (Access module with segments) DESCRIPTION OF KEYPAD (Access module with segments) For the most convenient control and status indication the JABLOTRON 100 system offers various types of access modules. Controlling (setting, unsetting

More information

ZITON RADIO LOOP MODULE

ZITON RADIO LOOP MODULE ZITON RADIO LOOP MODULE PROGRAMMING MANUAL Table of Contents Section Page No 1.0 INTRODUCTION...3 1.1 System Design...3 1.2 Handling Precautions...3 1.3 Packaging:...3 2.0 MENU STRUCTURE...4 2.1 Menu Structure

More information

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Operations Manual TS400. Test Station for G450/G460 Gas Detector TS400 Test Station for G450/G460 Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.goodforgas.com GfG Products for Increased Safety Congratulations

More information

PageOne 2-way Pager Assured 2-way messaging for critical communications

PageOne 2-way Pager Assured 2-way messaging for critical communications Operating instructions PageOne 2-way Pager Assured 2-way messaging for critical communications www.pageonepager.com Contents Foreword......................................................... 3 Getting

More information

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1 Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User

More information

Operation Manual For model CM706E

Operation Manual For model CM706E Operation Manual For model CM706E www.temperatureguard.com The CM706E is an environmental monitor with built in Ethernet and Cellular alarming and reporting capabilities. This unit can monitor up to ten

More information

600 Range Dialer Installation Manual. Version 1.0

600 Range Dialer Installation Manual. Version 1.0 600 Range Dialer Installation Manual Version 1.0 The information contained is supplied without liability for any errors or omissions. No part may be reproduced or used except as authorised by contract

More information

SolarSET GSM SolarSET GSM with a Beacon

SolarSET GSM SolarSET GSM with a Beacon Labkotec Oy Myllyhaantie 6 FI-33960 Pirkkala FINLAND Tel. +358 29 006 260 Fax +358 29 006 1260 13.08.2009 Internet: www.labkotec.fi SolarSET GSM SolarSET GSM with a Beacon Solar Powered Oil Separator Alarm

More information

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Revision 4/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

PBI Manual. Paradox to KNX-BUS Interface

PBI Manual. Paradox to KNX-BUS Interface PBI 64-192 Paradox to KNX-BUS Interface Manual GDS Intelligence in Buildings El. Benizelou 116 Nea Erithrea, 14671 Phone: +30 2108071288 Email: info@gds.com.gr Web: gds.com.gr Contents 1 Device description...

More information

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Operations Manual TS400. Test Station for G450/G460 Gas Detector TS400 Test Station for G450/G460 Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.gfg-inc.com GfG Products for Increased Safety Congratulations

More information

INSTALLATION and OPERATING INSTRUCTIONS ARITERM GSM A2

INSTALLATION and OPERATING INSTRUCTIONS ARITERM GSM A2 INSTALLATION and OPERATING INSTRUCTIONS ARITERM GSM A2 Introduction Ariterm GSM-A2 is a compact universal alarm transmitter that transmits alarms and receives commands via SMS. The alarm and status changes

More information

NookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E )

NookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E ) 1 Installation Guide NookBox Keypad (P119010 / E6309744) 2 NookBox Keypad (P119010 / E6309744) 3 Parts Identification 1. Active LED 2. Status LED 3. Fault Display LED 4. Arm Key 5. Home Key 6. Key Check

More information

BURGLAR ALARM PANEL BS-468

BURGLAR ALARM PANEL BS-468 BURGLAR ALARM PANEL BS-468 Contents 1. Description... 3 2. Instructions for the user... 4 2.1Basic operations... 4 Complete system.... 4 Split system.... 4 2.2 Armed system indication... 5 2.3 Advanced

More information

CRIME. Manufacturing And Minor Inventions CRIME. Control Room Integrated Monitoring Environment

CRIME. Manufacturing And Minor Inventions CRIME. Control Room Integrated Monitoring Environment Control Room Integrated Monitoring Environment INDEX 1. Requirements for software. 2. Installation Instructions. 3. How to Register your Software. 4. Start Using... 5. Operating Instructions. 6. Screen

More information

Advisor Advanced Mobile Application User Manual

Advisor Advanced Mobile Application User Manual Advisor Advanced Mobile Application User Manual Content Warnings and Disclaimers 2 Advanced Mobile 2 Contact information 2 Description 2 Screen navigation 4 Gestures 4 Menu 4 Help navigation 4 Login 5

More information

PAPERLESS RECORDER COMMUNICATION FUNCTION (Ethernet)

PAPERLESS RECORDER COMMUNICATION FUNCTION (Ethernet) Instruction Manual PAPERLESS RECORDER COMMUNICATION FUNCTION (Ethernet) TYPE: PHU INP-TN5A0024-E Note: MODBUS is the registered trade mark of AEG Schneider Aumaion International. NOTICE 1. Exemption items

More information

Watchguard WGAP864 User Manual

Watchguard WGAP864 User Manual Watchguard WGAP864 User Manual v1.0 Issued September 2016 1 2 Table of Contents Glossary... 5 1. Introduction to your Watchguard WGAP864... 6 2. Before Operating your Alarm System... 6 3. Understanding

More information

Monitoring Solutions

Monitoring Solutions GSM Systems Monitor: Temperature, Humidity, Power, Water, Smoke, Carbon Monoxide and More September 2016 Table of Contents GSM Systems... 3 Argon 100 GSM... 3 Ares 12 & 14 GSM... 4 Poseidon2 4002... 5

More information

GSM RFID VOICE Alarm System

GSM RFID VOICE Alarm System GSM RFID VOICE Alarm System User s Manual For a better understanding of this product, please read this user manual thoroughly before using it. CONTENTS [Function Instruction] [Control Panel] Control Panel

More information

RAy SNMP. Application notes.

RAy SNMP. Application notes. Application notes. RAy SNMP. version 1.0 12/29/2017 RACOM s.r.o. Mirova1283 59231 Nove MestonaMorave CzechRepublic Tel.: +420565659 511 Fax: +420565659 512 E-mail: racom@racom.eu www.racom.eu Table of

More information

ECO601 OPERATING INSTRUCTIONS ME04

ECO601 OPERATING INSTRUCTIONS ME04 RAK 72.2 9.11.2010 1 2 3 4 5 6 7 8 9 0 # ECO601 OPERATING INSTRUCTIONS ME04 PRESENTATION The ECO601 is intended for the simple control and surveillance of premises. This device can be controlled locally

More information

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE isocket Smart Relay is a complex Smart House system which is installed in the fuse cabinet (electric cabinet) in the house. We therefore assume that

More information

LevelSET S GSM Functionalities Instructions for Commissioning and Use

LevelSET S GSM Functionalities Instructions for Commissioning and Use Labkotec Oy Myllyhaantie 6 FI-33960 Pirkkala, Finland Tel: +358 29 006 260 Fax: +358 29 006 1260 22.10.2010 Internet: www.labkotec.fi LevelSET S GSM Functionalities Instructions for Commissioning and Use

More information

Laptop / PC Programming Manual

Laptop / PC Programming Manual Laptop / PC Programming Manual Doc. # Fire PC Program rev B 01.07 This Document is property of Evax Systems, Inc. The Evax Fire Solutions Programmer Components 2 1.0 System Setup 4 1.1 Interface Setup

More information

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output Model LFS108B Copyright 2018 - LLC. All rights reserved. Table of Contents Quick Start... 3 1- Introduction... 4 2-

More information

Mobeye CM2410 GSM fire alarm communicator

Mobeye CM2410 GSM fire alarm communicator PORTAL USER MANUAL Mobeye CM2410 GSM fire alarm communicator Accessory for Ei Electronics fire detector SW version 5.n Incl. CM2400 Attention! Very important This user manual contains important guidelines

More information

Simplex Panel Interface Guide

Simplex Panel Interface Guide Simplex Panel Interface Guide February 2016 SATEON Software Integrations Simplex Panel Interface Guide Issue 1.0, released February 2016 Disclaimer Copyright 2016, Grosvenor Technology. All rights reserved.

More information

Octalarm-T: the latest in future-proof industrial alarm diallers

Octalarm-T: the latest in future-proof industrial alarm diallers Octalarm-T: the latest in future-proof industrial alarm diallers Companies are becoming increasingly reliant on computers and technical equipment. Meaning you have to take steps to guarantee continuous

More information

Ion Gateway Cellular Gateway and Wireless Sensors

Ion Gateway Cellular Gateway and Wireless Sensors Page 1 of 9 Account & Network Setup If this is your first time using the Ion Gateway online system site you will need to create a new account. If you have already created an account you can skip to the

More information

Ontech GSM 9040/50. Reference Manual English -1 -

Ontech GSM 9040/50. Reference Manual English -1 - Ontech GSM 9040/50 Reference Manual English -1 - Content Welcome... 5 This manual... 5 Text styles... 5 Support... 5 Disclaimer... 5 Overview... 6 Accessories... 6 External temperature sensor 9901... 7

More information

SALES SUPPORT DOCUMENT

SALES SUPPORT DOCUMENT SALES SUPPORT DOCUMENT ML-1632 MAXLOGIC SUPERVISOR GRAPHIC MONITORING AND CONTROL SOFTWARE INTEGRATED WITH ENVIRONMENTAL SYSTEMS AND MANAGING ML-1632 supervisor software is a specially developed and easy

More information

TURN OFF ALARM AUTO ALARM RESET WRITE A COMMENT DISPLAY THE GUARDS GUARD FUNCTION RELAY INTERFACE:...

TURN OFF ALARM AUTO ALARM RESET WRITE A COMMENT DISPLAY THE GUARDS GUARD FUNCTION RELAY INTERFACE:... CONTENT version 2.03 1: PICCOLO - WIRELESS PROTECTION... 3 HOW THE PICCOLO SYSTEM WORKS... 3 SYSTEM DESCRIPTION... 3 DETECTORS... 3 ALARM RECEIVERS... 3 PICCOLO SERVER UNIT... 3 FORWARDING ALARMS (INTERFACES)...

More information

JA-63 Profi User manual

JA-63 Profi User manual JA-63 Profi User manual Contents: 1 Limited warranty... 2 2 Indicators... 3 3 Controlling the system... 4 3.1 Arming... 5 3.2 Disarming... 6 3.3 Panic Alarm... 6 3.4 To stop ALARM... 6 3.5 Home arming...

More information

Engine Control Unit, ECU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

Engine Control Unit, ECU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list OPERATOR'S MANUAL Engine Control Unit, ECU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax:

More information

User Manual & Setting Instructions

User Manual & Setting Instructions WT-9001 IP65 GSM Remote Controll And Allarm System User Manual & Setting Instructions WW II TT UU RR AA CC OO RR PPOO RR AA TT II OO NN SS DDNN BB HH DD WT-9001 IP65 GSM REMOTE CONTROL AND ALARM SYSTEM

More information

EZY SWITCH. SMS-IRR-4 System Monitor Installation Manual

EZY SWITCH. SMS-IRR-4 System Monitor Installation Manual EZY SWITCH SMS-IRR-4 System Monitor Installation Manual Table of Contents COMMANDS Getting Started Setting Up Initial User 7 Adding a User 8 Removing a User 8 Adding an Administrator 8 Removing the Administrator

More information

PERMACONN PM1030 Includes DI300. Installation Manual

PERMACONN PM1030 Includes DI300. Installation Manual PERMACONN PM1030 Includes DI300 Installation Manual Radio Data Comms Unit 5/20-30 Stubbs Street Silverwater NSW 2128 Telephone: 02 9352 1777 Facsimile: 02 9352 1700 Introduction The PERMACONN system provides

More information

ThermoBarScan TM Electronics UK Ltd INSTRUCTION BOOKLET

ThermoBarScan TM Electronics UK Ltd INSTRUCTION BOOKLET ThermoBarScan TM Electronics UK Ltd INSTRUCTION BOOKLET Model: MM7100-2D Index Introduction 1 PC Setup 2-3 Bluetooth Setup 4-5 Discovery 6 USB Setup for USB instruments 7 Setting Instrument Parameters

More information

Security Escort Central Console Software SE2000 Series

Security Escort Central Console Software SE2000 Series Release Notes Security Escort Central Console Software SE2000 Series Table of Contents 1 Security Escort v2.18.1.0... 2 1.1 Enhancements... 2 1.2 Errors Fixed... 2 1.3 Known Limitations and Restrictions...

More information

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1 ViewMatrix Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels Version: 2.0 Revision: 0.1 CONTENTS 1. Introduction...3 2. Keyboard...5 2.1 POWER indication - Normal Operation...5

More information

How to Configure the Alarm Action Outgoing Cell Call MultiLogger Application Note #14

How to Configure the Alarm Action Outgoing Cell Call MultiLogger Application Note #14 5 Gould Road, PO Box 2155 New London, NH 03257 Voice: (603) 526-9088 info@canarysystems.com www.canarysystems.com Overview How to Configure the Alarm Action Outgoing Cell Call MultiLogger Application Note

More information

InvisiFence User Manual

InvisiFence User Manual InvisiFence User Manual Version 1.2 Date May 2016 Table of Contents 1. Introduction... 3 2. General... 3 3. System Components... 4 4. Hierarchy of system components... 6 5. Processing unit Connections...

More information

FIRE SMS K T P EVACUATION ALERT SYSTEM UK LLP. FIRE SMS is a fire alarm service for deaf and hard of hearing people.

FIRE SMS K T P EVACUATION ALERT SYSTEM UK LLP. FIRE SMS is a fire alarm service for deaf and hard of hearing people. K T P UK LLP FIRE SMS EVACUATION ALERT SYSTEM FIRE SMS is a fire alarm service for deaf and hard of hearing people. It helps service providers and employers comply with the Equality Act 2010 and manage

More information

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

PRODUCT CATALOGUE.   Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg PRODUCT CATALOGUE Cape Town 18 Darter Road Blue Water Estate Kommetjie Luke Fowles - 076 161 8124 luke@providenttech.co.za Frank Fowles - 082 445 1541 frank@providenttech.co.za www.providenttech.co.za

More information

Sensor Cloud User Manual

Sensor Cloud User Manual Sensor Cloud User Manual Table of Contents DEVICES TAB 4 1. DEVICE LIST 4 2. EXPAND ALL 4 3. EXPAND 4 4. STATUS 4 5. DEVICE 4 6. NAME 5 7. MONITORING INTERVAL 5 8. LAST ACTIVITY 5 9. VIEW 5 10. DELETE

More information

Summit 3208GLD USER MANUAL. Electronics Line

Summit 3208GLD USER MANUAL. Electronics Line Summit 3208GLD USER MANUAL Electronics Line Table of Contents 1: Introduction... 2 2: Overview... 3 3: Keypad Functions... 4 3.1: Keypads... 4 3.2: 3108 LCD Keypad Layout... 4 4: Basic System Operation...

More information

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n SW version 5.n PORTAL USER MANUAL Mobeye WaterGuard-FS Float sensor CM2300FS Attention! Very important This user manual contains important guidelines for the installation and usage of the Mobeye device

More information

Trident User s Manual

Trident User s Manual Labkotec Oy Myllyhaantie 6 33960 Pirkkala FINLAND Tel. +358 (0)29 006 260 18.05.2017 Fax +358 (0)29 006 1260 Internet: www.labkotec.fi 34 pages Trident Copyright 2017 Labkotec Oy 1/34 TABLE OF CONTENTS

More information

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460) Operating Manual TS400 Test Station for Microtector II Series (G450/G460) GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)2 31 / 5 64 00 0 FAX +49 / (0)2 31 /

More information

Kaleidescape Programming Manual for Elan Home Systems

Kaleidescape Programming Manual for Elan Home Systems Kaleidescape Programming Manual for Elan Home Systems Rev.1, July 2008 Elan Templates v1.0 2007-2008 Kaleidescape, Inc. All rights reserved. Kaleidescape and the Kaleidescape logo are trademarks of Kaleidescape,

More information

Vehicle Tank Protection TANKSAVE. Fuel anti-theft system. Deters Warns

Vehicle Tank Protection TANKSAVE. Fuel anti-theft system. Deters Warns Vehicle Tank Protection Fuel anti-theft system Deters Warns PRESENTATION This system is available in three versions : 1. Use of the gauge fuel vehicle -. Basic Version 2. Using a probe to put in the tank

More information

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide MG6250 2-Partition 64-Zone Wireless Console with GPRS/GSM Version.6 Section Programming Guide Things You Need to Know About this Programming Guide The MG6250 All-in-one Wireless Console can be programmed

More information

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0 IRIS Touch 400 & 600 Range Installation Manual Honeywell Galaxy Range Version 2.0 Table of Contents 1 System Overview... 4 2 IRIS Touch 440 & 640 PCB Layout... 5 3 Connection & Configuration for Honeywell

More information

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training PowerWizard Level 1.0 & Level 2.0 Control Systems Training New Systems Current Systems Systems Comparison Level 1 Level 2 Level 3 Level 4 PowerWizard Level 3.0 PowerWizard Level 4.0 Overview Common parts

More information

3D_ISS. Integrated Software System. User Guide Manual

3D_ISS. Integrated Software System. User Guide Manual 3D Digital Design & Development LTD 58/60 Edward Road Tribec House New Barnet EN4 8AZ 020 8440 7060 3D_ISS Integrated Software System User Guide Manual Copyright 2014 3D Digital Design and Development

More information

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0 M2M Services Ltd. RControl Alarm - Installer Manual V 1.0 Content Content... 2 Wiring the power supply module... 3 Wiring a siren... 3 SMARTEnroll self-learning zones... 3 Wireless keyfobs... 3 Supported

More information

METOS Compact SMS. The smooth change of a product. Gottfried Pessl

METOS Compact SMS. The smooth change of a product. Gottfried Pessl METOS Compact SMS The smooth change of a product Gottfried Pessl METOS Compact the Technical Specifications Single Board Climate Station 512 kb Flash Memory 8 bit Siemens µprocessor 12 Minute Measurement

More information

3 User s settings. 3.3 Internal clock setting

3 User s settings. 3.3 Internal clock setting 2.9 Subsystem arming In a large building a sub control panel can be enrolled to the JA-63. The subsystem reports all alarms and failures to the main system. The installer can program if the systems will

More information

HikCentral Web Client. User Manual

HikCentral Web Client. User Manual HikCentral Web Client User Manual Legal Information User Manual 2018 Hangzhou Hikvision Digital Technology Co., Ltd. About this Manual This Manual is subject to domestic and international copyright protection.

More information

Fire Control Panel FS4000

Fire Control Panel FS4000 Fire Control Panel FS4000 INSTRUCTION MANUAL Revision 4/02.11 Contents 1. Introduction... 4 2. Terminology... 4 3. Function... 5 4. Technical features... 5 4.1 Fire alarm lines... 5 4.2. Current thresholds

More information

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power T M User Manual MarinaGuard Ground Fault Monitoring Panel For Marina Shore Power NAE1095810 / 03.2013 T M Bender Inc. USA: 700 Fox Chase Coatesville, PA 19320 Toll-Free: 800-356-4266 Phone: 610-383-9200

More information

3i SECURITY with i-mode Welcome to the future of security. Today with your i-mode telephone you have full control of your home and automobile even when you are not present. You may see directly on your

More information

M3092 Programmer. User s Manual. M3096B-33 E Copyright 2017 SELCO

M3092 Programmer. User s Manual. M3096B-33 E Copyright 2017 SELCO User s Manual Copyright 2017 SELCO SELCO Betonvej 11 - DK-4000 Roskilde Denmark Phone: 45 7026 1122 - Fax: 45 7026 2522 e-mail: selco@selco.com www.selco.com Table of contents 1 INTRODUCTION...4 2 SOFTWARE

More information

GSM Emergency Alarm. User s Manual. For a better understanding of this porduct,please read this user manual thoroughly before using it.

GSM Emergency Alarm. User s Manual. For a better understanding of this porduct,please read this user manual thoroughly before using it. Version: MS1 GSM Emergency Alarm User s Manual For a better understanding of this porduct,please read this user manual thoroughly before using it. CONTENTS CONTENTS Ⅰ. Introduction Ⅱ. Product Appearance

More information

DX2002 OPERATING AND PROGRAMMING INSTRUCTIONS

DX2002 OPERATING AND PROGRAMMING INSTRUCTIONS DX2002 OPERATING AND PROGRAMMING INSTRUCTIONS The four pushbuttons located at the bottom right of the circuit board are used to do all programming. Each button has more than one function. Alternate Settings

More information

Control panel «Contact GSM-5-2»

Control panel «Contact GSM-5-2» Control panel «Contact GSM-5-2» Operating Manual Rev. 1.1 Saint Petersburg, 2017 Table of Contents Introduction 4 Panel Overview 5 Designation 5 Capabilities 6 Specifications 9 Design 11 Delivery Package

More information

Please use authentic SATA hard drive, USB device and battery.

Please use authentic SATA hard drive, USB device and battery. Note The device should be set in the room with good ventilation, far from water, hot reservoir or dust. Network Video Recorder is not designed to be used outdoor. Please use authentic SATA hard drive,

More information

User manual. KNXgal. version

User manual. KNXgal. version User manual version 1.3 gal Management alarm control panels Galaxy from bus powered from bus Communication indication on and with Galaxy control panel DIN rail mount (1 modul) Adjustable address on with

More information

Added password for IP setup page : Password must be in IP format!

Added password for IP setup page : Password must be in IP format! NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP

More information

Technical Specification. For. Arla Tankvagt

Technical Specification. For. Arla Tankvagt Technical Specification For Arla Tankvagt Tankvagt - technical specifications ver. 4.2 CONTENT 1 DOCUMENT CONTROL...2 1.1 Revision History...2 1.2 Reviewers...2 1.3 Related Documents...2 2 INTRODUCTION...3

More information

Lone Worker Duress Security Hazard Zone Remote Area Health Care DURESS & SAFETY TECHNOLOGIES I N T E R N A T I O N A L

Lone Worker Duress Security Hazard Zone Remote Area Health Care DURESS & SAFETY TECHNOLOGIES I N T E R N A T I O N A L Lone Worker Duress Security Hazard Zone Remote Area Health Care DURESS & SAFETY TECHNOLOGIES www.duressandsafety.com.au Creating safer environments for people Increasingly organisations recognise the need

More information

HikCentral Web Client. User Manual

HikCentral Web Client. User Manual HikCentral Web Client User Manual Legal Information User Manual 2018 Hangzhou Hikvision Digital Technology Co., Ltd. About this Manual This Manual is subject to domestic and international copyright protection.

More information

EURO 46 V10 User Manual

EURO 46 V10 User Manual EURO 46 V10 User Manual PD6662:2010+IA501:2015 EN50131-1:2008+A1:2009 EN50131-3:2009 Security Grade (SG) 3 - Large Security Grade (SG) 2 - Small Environmental Class (EC) II Software Version >10 RINS1943-1

More information

RESET + Password Enter (During Auto Speed Procedure) Maintenance Timeout or after TEST + RESET + DISABLE (No Need for Device to Initialize)

RESET + Password Enter (During Auto Speed Procedure) Maintenance Timeout or after TEST + RESET + DISABLE (No Need for Device to Initialize) FAAST LT FIRE ALARM ASPIRATION SENSING TECHNOLOGY ADVANCED SET-UP AND CONTROL GUIDE CONTENTS Introduction....1 The FAAST LT Functional State Diagram....1 Password Procedure (to enter Maintenance Mode)

More information

AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL

AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL M 890-00279 rev. 14 K 895-00004 rev. 00 Manufacturer: Viatron Electronics 5200, Armand-Frappier St-Hubert (Quebec) Canada J3Z 1G5 WARNINGS The warranty can be void

More information

Quick Reference Guide

Quick Reference Guide infinite Prime with Hybrid Connections User Manual - Version 1.00 Catalog Number: ZI0473A (1/07) All data is subject to change without prior notice. Hereby, Electronics Line 3000 Ltd. declares that this

More information

CBI-064. User Manual. Caddx to KNX-BUS Interface

CBI-064. User Manual. Caddx to KNX-BUS Interface CBI-064 Caddx to KNX-BUS Interface User Manual GDS Intelligence in Buildings El. Venizelou 116 Nea Erithrea 14671 Tel: +30 2108071288 Email: info@gds.com.gr Web: gds.com.gr Contents 1 Device Description...

More information