X11CA COMPUTER ANNUNCIATORS
|
|
- Randell Watson
- 5 years ago
- Views:
Transcription
1 S E R I E S XCA COMPUTER ANNUIATORS E N G I N E E R I N G C O M P A N Y
2 The Ronan Series XCA Computer Annunciators are the latest generation of Ronan s state-of-the-art annunciators offered in window models. The XCA is designed for the process and power industries requirements, providing the most economical approach while offering the most advanced data acquisition in serial technology and monitoring, along with Ronan s high quality and performance standard. The systems in the Window Annunciator feature Monalarm, Dualarm, Trialarm and Quadalarm within Ronan s standard.0 inch (88.90 mm) by.0 inch (88.90 mm) mechanical cabinet modules. A system common trouble and a per-point auxiliary relay output may be utilized for field contact repeater or for remote group alarms. The system monitors internal routines and communication backbone, signaled by dedicated LED or relay contact closure. The XCA is equipped with a host interface module that provides advanced communication interface protocols to interface with an external host computer, local network, or plant network. F E A T U R E S INPUTS Dry Contact, System Powered Vdc ly Open/ly Closed Live Contacts (Isolated) Vdc, 8 Vdc, Vdc or Vac, 0 Vac SEQUEE All Standard ISA s User Configurable OUTPUTS Dual Configurable Auxiliary Contact Double Throw Selectable ly Energized or De-energized GP or HS Relays May be Added in the Field Common System Trouble Reflash System Trouble Serial Input/Output Protocol Ronan Proprietary MODBUS RTU Slave TCP/IP DNP.0 Serial Interface Object Linking and Embedding for Control (OPC) DESIGN TECHLOGY Microprocessor Based Noise Immunity Field Proven Off-the-shelf Worldwide Serial Input/Output Comprehensive User Configuration with Standard Software MECHANICAL Flush Ergonomic Front Panel Design Total 7.0 Inches (90.0 mm) Deep Light Weight Reinforced Terminal Block LIGHTING LED Colors: Red, Green, Amber, White, Blue Dual Bulbs Watts Each (Can use Watt with Transparent Film) COLOR CODING Eight Bezel Colors Colored Lenses Sandwich Lenses WARRANTY Three () Years APPROVALS UL Underwriters Laboratories CUL Canadian Underwriters Laboratories EMI/RFI CAPABILITY IEC 80-, -, -, - CE Compliant to EN008-/ EN008-
3 SYSTEM ELOSURES The Ronan XCA Computer Annunciator Systems with microprocessor based electronics are assembled from basic.0 inch (88.90 mm) by.0 inch (88.90 mm) modules to make up the overall size requirements and number of windows required. The mechanical modules assembled from aluminum castings and extrusions provide excellent heat dissipation for a continuously lit annunciator system and feature the structural strength required in industrial applications. The rear terminal is designed as a single piece molded plastic assembly per window for durability. A small. inch (8. mm) wide x 7. inch (89. mm) high x.00 inch (.0 mm) deep module (interface module), is provided to connect the system to an external host. All enclosures are painted with baked black semigloss enamel. Custom colors are optionally available. NEMA OR NEMA WINDOW The Panel-mount enclosure may be enhanced with a NEMA or NEMA door assembly to seal the front of the alarm system against control panels where it is subject to moisture or corrosive atmosphere. The door is supplied with a clear acrylic window, sealed with a neoprene gasket. Gasketing is supplied for sealing between door frame and control panels. PANEL-MOUNT The Panel-mount NEMA type enclosure, for control panel applications, mounts through a rectangular cutout and secures to the panel with a number of simple clamping devices supplied with each system. RACK-MOUNT The Ronan alarm system with various window sizes is available for standard 9.00 inch (8.0 mm) or.00 inch (09.0 mm) relay rack mounting. The five mechanical module wide unit is suitable for 9.00 inch (8.0 mm), and the six module wide unit can be used for.00 inch (09.0 mm) rack spacing. SURFACE-MOUNT The Ronan Surface-mounted mechanical arrangement alarm system provides front termination access. It is used for applications where the annunciator is to be in an explosion proof housing or NEMA enclosure, and for applications where a surface mounted window annunciator is found more suitable.
4 TEST SIL ACK RESET MONALARM, DUALARM, TRIALARM, QUADALARM SERIES MODELS XCA , - 000,-000,-000 This Panel-mounted Series of computer annunciators is used for control panels. Various colors of bezels are available with four different configurations housed within the mechanical cabinet modules. A Overall B Cutout A 0.8" (9. mm) Maximum Panel Thickness A Overall B Cutout Optional Push Buttons 7.78" (97. mm) 9." (.9 mm) 0.7" (9.0 mm) Conduit Knock-out Optional Rear Cover MODELS XCA-RR , -000,-000,-000 The Relay Rack-mounted Series of computer annunciators has a standard length of 9.00 (8.0 mm). An optional.00 (09.0 mm) length is also available. 8." (.07 mm).8" (0. mm) A Overall Field Contact Terminals 9.00" (8.0 mm) Overall." (9.78 mm) Fuse MODELS XCA/XCA-RR , - 000,-000,-000 Rear Terminal Arrangement for Wiring Notes for XCA/XCA-RR: (H) Field Contact Voltage for Dry Contact or Live Input (FC) Field Contact Return (ME) Connect All First Out in a Group (TO) Transistor Output Driver Auxiliary Output / Selectable Notes for XCA-IM: TO: A, A, CTA, RFL RUN for Transistor Driver* A, A, CTA, RFL, RUN for Relay Output** : ly Open COM: Common : ly Closed A: Horn A: Horn CTA: Common Trouble RFL: Reflash RUN: System Diagnostic GP, GP: Programmable Function (Special Function) D C B Field Control Wiring for All Positions Dry A D C B A D C B A FV V+ V- G Communication Cable Live + XCA-000 (H) (FC) (ME) (TO) + Vdc Power Supply To XCA-IM Aux. Output
5 Panel Front Frame Clamp Assembly Jam Nut Cabinet Detail A XCA-000 XCA-000 XCA-000 XCA Specifications subject to change without notice. Inches A Overall mm Inches B Cutout mm Nameplate Sizes: Monalarm.00 inches (7.0 mm) x.00 inches (7.0 mm) Dualarm. inches (.8 mm) x.00 inches (7.0 mm) Trialarm 0.8 inches (.8 mm) x.00 inches (7.0 mm) Quadalarm.0 inches (. mm) x.0 inches (. mm) XCA-RR-000 XCA-RR-000 XCA-RR-000 XCA-RR-000 ** ** ** 0** * 8* * 8* * Not limited to high. ** Limited to wide only (8.0 mm) rack. Also available wide.00 (09.0 mm) rack. * Not limited to 8 high. ** Limited to wide only (8.0 mm) rack. Also available wide.00 (09.0 mm) rack. * Not limited to high. ** Limited to wide only (8.0 mm) rack. Also available wide.00 (09.0 mm) rack. * Not limited to 8 high. ** Limited to 0 wide only (8.0 mm) rack. Also available wide.00 (09.0 mm) rack. Inches A Overall mm Field Control Wiring for All Positions Dry Live + B A FV V+ V- G B A B A Test Silence (H) (FC) Reset (ME) (TO) First Out Reset GP Aux. Output GP RS8 To Host RS A A TO CTA RFL RAN A COM A COM CTA COM RFL COM RUN COM GND V- V+ V+ XCA-IM TEST SIL ACK RST FRST GP GP TX+ TX- P GND RS8 RX+ RX- PRGM RUN P RS P * ** AC Horn Horn Horn Electronic Horn To Power as Required XCA-000 (+) Vdc ( ) Power Supply or DC to DC Converter P P RXD TXD RXD TXD ERROR RUN XCA-IM H(+) N( ) G Communication Cable Vac or Vdc * Open Collector Outputs **Relay Contact Outputs
6 SEQUEE DIAGRAMS Return to Off To while Return to Off First to Subsequent to d while or or Subsequent On Flashing On SEQUEE A Automatic Reset and Test Push Buttons Device Lock-in of Momentary s until d The Device is Silenced and Flashing Stops when d Automatic Reset of d Indications when Conditions Return to Operational Test Return to Subsequent to d On and Test Push Buttons Device Lock-in Momentary First until d No Lock-in of Momentary Subsequent s Flashing and Indications for First Only New Subsequent s Go to the d State First Out Indication is Reset and the Device is Silenced when d Automatic Reset of d Indications when Conditions Return to Operational Test Off while (First Out Reset) while (First Out Reset) SEQUEE FA Automatic Reset First Out with No Subsequent State First to or First Flashing or d On (First Out Reset) (First Out Reset) or First Silenced Flashing Silence or First Flashing SEQUEE FM- Manual Reset First Out with No Subsequent Flashing and Silence Push Button Silence,, Reset and Test Push Buttons FA, Automatic Reset First Out Device with No Subsequent State d Option : Silence Push Button to Silence the Device while Retaining First Out Flashing Indication Flashing Indication for First Only New Subsequent s have the Same Indication as d s First Out Indication is Reset when d Manual Reset of d Indications, Conditions Return to Operational Test ORDERING Typical Method of Specifying s with Options Using ISA Standard Nomenclature Basic Letter R Option Numbers F M - Basic Letter Option Number First Out Designation
7 Return to Off First to Reset while Off To while Subsequent to or Subsequent or d or Fast Flashing On Flashing First Out Reset while Subsequent d On while First Out Reset or First d Flashing or First Intermittent Flashing SEQUEE M Manual Reset, Reset and Test Push Buttons Device Lock-in Momentary s Until d The Device is Silenced and Flashing Stops when d Manual Reset of d Indications after Conditions Return to Operational Test SEQUEE FA Automatic Reset First Out Reset with First Out Flashing and Reset Push Button First Out Reset and Test Push Buttons Device Lock-in of Momentary s until d First Out Flashing Different from Subsequent Flashing First Out Reset Push Button to Change the First Out Indication to be the Same as Subsequent Indications Automatic Reset of d Indications when Conditions Return to Operational Test Ringback Reset RingBack Slow Flashing Ringback Off while Return to To Ringback or Fast Flashing Basic Option Key Words Number Letter Key Words A Automatic Reset Silence Push Button M Manual Reset Silence Interlock R Ringback First Out Reset Interlock No Lock-in No Flashing No 7 Automatic Silence 8 Common Ringback 9 Automatic Ringback Silence First Out Option Key Words Designation Number Key Words F No Subsequent State 0 No Ringback F No Subsequent Common Ringback Flashing F First Out Flashing and Automatic Momentary Reset Push Button Ringback Dim Lamp Monitor Lamp Test Return to Ringback On while SEQUEE R Ringback, Reset and Test Push Buttons and Ringback Devices Lock-in of Momentary s until d The Device is Silenced and Fast Flashing Stops when d Ringback and Indications when Conditions Return to Manual Reset of Ringback Indications Operational Test 7
8 XCA MODULES HOST INTERFACE MODULE The Model XCA-IM Interface Module connects the XCA Window Annunciator with external host devices. Hosts can be a DCS, PLC, or plant computer. An isolated RS8 or a 0 Base T network connection is used with the most common industry accepted communication standards such as MODBUS, DF, and TCP/IP protocols for host communication. The Module provides a number of special features such as time-stamped event archive, common trouble alarm, dual horn output, reflash output, and system diagnostic output. All 7." (8.0 mm) 7." (89. mm).00" (7.0 mm).00" (.0 mm) V+ XCA-IM A TEST A SIL TO CTA ACK RFL RST RAN FRST GP A COM GP TX+ TX- A COM P GND RS8 RX+ RX- CTA COM RFL COM PRGM RUN P RS RUN COM GND V- V+ P P P RXD TXD RXD TXD ERROR RUN." (8. mm) 0." (.0 mm) Dia. outputs are provided in the forms of an open collector transistor and selectable Form C relay dry contact. Additional on-board LEDs are designed to indicate serial communication and system status. The XCA-IM Interface Module is used to interface via a laptop or PC with the Ronan XCA configuration software for programming sequences, input/output assignment, and all other selectable features. ALARM SEQUEE/DISPLAY MODULE 8 The Ronan Model XCA Annunciator module is designed with all common sequences and options available internal to the module, allowing for field programmable selections of all commonly used ISA sequences through a computer or laptop. Selection of field contact polarity is allowed through the on-board jumpers per channel. Each combination of alarm/display module contains a single, dual, triple, or quad alarm channel with associated lamp or LED displays. The modules are removable from the front without interfering with the system. The XCA Window Annunciator display lens area is a back-lit window with standard colored bezels. The single or sandwich lens allows multi-line legend.
9 MONALARM The Monalarm plug-in Module features single channel alarm logic with two -watt incandescent or optional LED type indicators illuminating a.00 inch (7.0 mm) high by.00 inch wide (7.0 mm) window. DUALARM The double window Dualarm Module contains two channels of alarm logic to display alarm conditions on two windows sized for. inch (.8 mm) high and.00 inch (7.0 mm) wide lenses. TRIALARM The three window Trialarm Module provides three 0.8 inch (.8 mm) high by.00 inch (7.0 mm) wide nameplates and is illuminated by three sets of two -watt lamps or LED type indicators. Each set is driven by one channel of the three-channel alarm logic. QUADALARM The four window Quadalarm Module represents the highest density of annunciation in the XCA series. The.0 inch (. mm) high by.0 inch (. mm) wide window is illuminated by two -watt lamps or LED indicators. 9
10 XCA MODULES PUSH-BUTTON CONTROL The XCA system provides for an integral membrane push-button interface module or, as an option, a membrane switch overlaid on the rim of the system frame. The latter design allows full use of all module position input channels in each system. All external push buttons are interfaced through the interface module. The system alarm input modules provide self-generating flash signals that operate the flash sequence on indicators independently. All module flash generators are synchronized by the interface module. AUXILIARY CONTACT MODULES The Auxiliary Contact Modules are available for the XCA Window Annunciator with a separate relay circuit for each window. The modules plug in from the front of the system. They may be purchased initially, or added later in the field without any additional system components. Each relay provides for a form A or B type contact, normally open or normally closed, and normally energized or normally not energized, and is selectable by a jumper switch. 0
11 COMMUNICATION / PROTOCOLS The Ronan XCA Window Annunciators have comprehensive serial alarm communication facilities to interface to Host machines and transfer field input status to, or receive alarm data from PLCs, DCSs, Network Servers and Computers. MODBUS RTU SLAVE The MODBUS RTU Slave protocol allows users of PLCs and DCSs that are operating as MODBUS Masters to periodically acquire the status of annunciator inputs or transmit alarms to the annunciator for process monitoring. Status of the annunciator is continuously updated in a pre-defined Memory Register Map which complies to the MODBUS protocol. The Host (MODBUS Master) periodically reads or writes to the Memory Register Map serially using pre-defined MODBUS command sets. The data is then used for process monitoring. Events XCA-IM DCS, PLC or Computer XCA ALLEN BRADLEY DF INTERFACE The Allen Bradley DF protocol allows users of AB PLCs to periodically acquire or transmit alarm data to or from the annunciator for monitoring and control. The input status is periodically transmitted as a bitmap complying to the DF protocol. The PLC provides an open serial port to send or receive the bitmap status.
12 COMMUNICATION / PROTOCOLS NETWORK TCP/IP Transport Control Protocol/Internet Protocol (TCP/IP) The Ronan XCA provides as an optional connection to a local or plant network using the XCA-IM interface module and XCA-NM network converter module. The input alarm status is transmitted or received via TCP/IP at speeds of up to 0 MB all across the network. Typical TCP/IP Address Base T Ethernet 0 Base T XCA-IM XCA-NM Network Hub XCA Other Network Device Plant Network RONAN PROPRIETARY (/) The XCA provides features to serially transmit input alarm status to external host devices through XCA-IM. This feature can be used to transfer input alarm status serially to Ronan s X0 Serial Annunciator for remote visual annunciation display. Lamp Box Lamp Box XCA-IM X0-A X0-B XCA Events RS/RS8
13 OPC INTERFACE (Object Linking & Embedding for Control) OPC is designed to allow client applications access to alarm input status of a system in a consistent manner. With wide industry acceptance, OPC provides easy integration into the common Human Machine Interface (HMI) applications widely used in the process industry. OPC Client OPC Client Local OPC Server Ronan OPC Interface Driver XCA Ethernet Network OPC Server XCA-NM Ronan OPC Driver OPC Interface Typical TCP/IP Address XCA-IM TYPICAL APPLICATION The XCA Serial Annunciators features an optional bit NT driver and mechanisms for OPC clients to be notified of the occurrences of specified events and alarm conditions. They also provide services which allow OPC clients to determine the events and conditions supported by an OPC server, and to obtain their current status. Graphics OPC Client Typical TCP/IP Address Computer with HMI Interface OPC Server XCA-NM XCA-IM XCA Plant Ethernet Network
14 CONFIGURATION XCA-CONFIGNT The Ronan XCA Window Annunciators are configured fully with the use of a graphical user interface application operating in a environment on a PC or Laptop through an RS serial connection to the XCA-IM interface module. The application allows factory or field programmability of all features for each window. Configuration data is saved in non-volatile memory on-board each module. Selections such as alarm sequence, first out grouping, operational or lamp test, output signals follow alarm or field contact, time delay and special functions are all set through the configuration application software.
15 BEZELS AND ENGRAVING The XCA Window Annunciator can be supplied with engraved letters (top two examples) for all different models of bezels, or customized with laser printed lettering (bottom two examples) on heat resistant, translucent thin film material. Letter Size (Inches) Characters per Line Lines Bezels Shown Actual Size Monalarm Series 000 Model WB-( )* Dualarm Series 000 Model WB-( )* Trialarm Series 000 Model WB-( )* Quadalarm Series 000 Model WB-( )* *Color code typical bezel ordering information: WB-(0) = Black bezel for Trialarm Series
X16PDM P R O G RAMMABLE
S E R I E S XPDM P R O G RAMMABLE D I G I T A L M O N I T O R S E N G I N E E R I N G C O M P A N Y The Ronan Series XPDM Programmable Digital Monitors are the latest generation of Ronan s state-of-the-art
More informationAIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)
AIS750 Series Alarm Annunciator User Manual (Ver 23 / JUNE 2014) 3-350 John Street, Thornhill, tario L3T 5W6 Phone: 289 597 APEX (2739) Fax: 289 597 2200 Toll Free: 1 866 776 2943 Email: mail@annunciatorca
More informationAIS750 Series Alarm Annunciator
Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual &
More informationReplaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge
Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays
More informationModel A1700 Series Annunciator
Seekirk Model A1700 Series Annunciator Applications: For usage in all types of process industries, electric generation, transmission and distribution, gas and water utilities. Features: The Seekirk model
More informationAN-3100D Annunciator
AN-3100D Annunciator FOR POWER GENERATION, TRANSMISSION & DISTRIBUTION, PETROLEUM, PETROCHEMICAL, AND OTHER PROCESS INDUSTRIES INNOVATIVE ANNUNCIATOR Continuing with the widely successful AN-3100 series
More informationSeries 725 Programmable Alarm Annunciator
Series 725 Programmable Alarm Annunciar Multi-redundant design for greater reliability Modular construction from 1 256 alarm channels Multi-redundant design so there is no single point of failure Choice
More informationSystem 9000TS Sequence of Events Recorder
System 000TS Sequence of Events Recorder ms Event Recorder and combined Annunciator Modular, rack mounting design expandable to over 000 inputs ms time stamping of events across the whole system Up to,000
More informationModel A1600 Series Annunciator
Seekirk Model A1600 Series Annunciator Applications: For usage in all types of process industries, electric generation, transmission and distribution, gas and water utilities. Features: The Seekirk model
More informationModel A2100 Series Annunciator
Seekirk Model A2100 Series Annunciator Applications: For usage within transformers, switchgear, breakers and/or within any processing equipment or control room applications either attended or unattended
More informationDRAFT 20 October 2014
Technical data MTL process alarm equipment EPS rev 8 Programmable alarm annunciator Modular construction from 1 to 256 alarm channels Multi-redundant design so there is no single point of failure Choice
More information21-light Remote Annunciator. Owner s Manual
21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With
More information4 & 8-POINT ANNUNCIATORS Instruction Manual
4 & 8-POINT ANNUNCIATORS Instruction Manual 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal
More informationAcross-the-Line SERIES MP300 Combined Manual and Automatic
Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps
More informationSoft Start Series MP700 Solid State, Reduced Voltage
Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s
More informationInstruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual
Instruction manual MTL process alarm equipment October 2016 CSM 725B rev 2 MTL RTK 725B Configuration Software Manual SECTION 1 - INTRODUCTION... 5 Basic Requirements... 5 SECTION 2 - SOFTWARE INSTALLATION...
More informationPD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual
PD154 & PD158 VIGILANTE II ANNUNCIATORS 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal Power
More informationSIL725 Safety Annunciator
SIL725 Safety Annunciar Configurable SIL2 Annunciar certified IEC61508 SIRA certified at safety integrity level SIL2 IEC61508 Modular construction from 1 128 alarm channels Multi-redundant design Choice
More informationRTK 9000TS system. MTL sequence of events recorder. Technical data MTL process alarm equipment
Technical data MTL process alarm equipment EPS RTK 9000TS Rev RTK 9000TS system MTL sequence of events recorder Modular, rack mounting design expandable to over 900 inputs ms time stamping of events irrespective
More informationType 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B
PRODUCT BULLETIN SB 8001B Type 8001 ALARM ANNUNCIATOR TYPE8001 FEATURES 16 or 32 alarm points per flush mount enclosure Displays are backlit with long life LEDs and engraved to suit Dimmer controls built
More informationComplex alarming made simple
SEL-2523 Annunciator Panel Complex alarming made simple Superbright LEDs provide easily visible alarm indication in any lighting condition. Sequential Events Recorder (SER) data help identify the root
More information725B Configuration Software Manual
725B Configuration Software Manual REV DATED DESCRIPTION AUTHOR APPROVED 0 09-03-10 First Issue P.Cartmell Page 1 of 80 SECTION 1 - SOFTWARE INSTALLATION... 5 725B ConfigurationSoftware Installation...
More informationAO Annunciator Module
General Specifications GS48C43Z01-00E-N AO-543-01 Annunciator Module GENERAL Figure 1 This module has two independent annunciator circuits. The circuits handle fault signals and operator actions (acknowledge,
More informationSystem 9000TS Event Recorder
Important notes The 9000TS System described herein operates on a logic voltage of VDC and as standard +VDC is used for the field contact supply voltage. External power supplies using higher voltage ac/dc
More informationESP TECHNOLOGIES LIMITED
Alarm Technology ESPAN-01 Series Annunciator System Combination type User Manual (Rev. 1) ESP TECHNOLOGIES LIMITED www.esptechno.com Content Page Introduction 2 General Description 2 Overview - Annunciator
More informationVariable Frequency Drive SERIES MP800 VFD
Metron Fire Pump Controls and Accessories Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for
More informationAnnuciator Logic Controllers
C B0 C C5 C C6 C C7 A B A B A B A B A5 B5 A6 B6 A7 B7 A8 B8 A9 B9 5 Annuciator Logic Controllers 68 c5 c6 c7 B B B B B5 B6 B7 B8 B9 B0 B B B B B5 B6 C0 BUZZER RETURN BZ M / BZ CTROL SIGNAL LAMP DC() DC()
More informationInstallation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D
ASCO 5350 The ASCO 5350 ATS Remote Annunciator is listed under the Underwriter s Laboratories Standard UL-1008 for Automatic Transfer Switch accessories. This stand-alone device provides individual status
More informationConventional Releasing Control Panel
s Data Sheet Fire Safety Products Conventional Releasing Control Panel Pre-Action Deluge Agent-Releasing Fire System Model TXR-320 Remote configurable Up to two (2) hazard areas Operable with the following:
More informationANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual
ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual From urgent alarms to routine messages, the PD141AFO VIGILANTE handles all types of operational messages with simplicity and economy. The VIGILANTE
More informationSUB-STATION ANNUNCIATOR INSTRUCTION MANUAL
SUB-STATION ANNUNCIATOR INSTRUCTION MANUAL Page 1 of 76 The following methods are used in this manual to alert the user to important information:- WARNING! Warnings are provided for operator safety and
More informationSystem 9000TS Sequence of Events Recorder
System 9000TS Sequence of Events Recorder ms Event Recorder and combined Annunciator The RTK System 9000TS Sequence of Events Recorder leads the way in the latest technically advanced event and alarm management
More informationME 3011C / Alarm Indication / Quick Reference Guide
Tables of Contents Page Application 1 Features 1 Important Safety Information! 2 Note to this Guide 2 Further Information 2 Device Variants 2 General Functions 3 Annunciator Sequences - ISA 18.1 3 Plan
More informationPlant Security & Fire Alarm Systems. HVAC Systems. Power Plants & Switchyards. Geographical Maps. Industrial Process Plants
Plant Security & Fire Alarm Systems HVAC Systems Power Plants & Switchyards 2 The Ronan Series X71 Mosaic Graphic System is ideally suited for the graphic display of industrial processes, power distribution
More informationFor Complete Fire and Gas Solutions
Industrial Fire For Complete Fire and Gas Solutions 2 The Total Package What do you need from an integrated fire and gas system? In industrial fire and gas environments it s important to have a reliable
More informationIntesisBox BACnet/IP Server - Notifier ID3000 series
IntesisBox Server - Notifier ID3000 series Gateway for integration of Notifier ID3000, ID3002, ID50 and ID60 fire panels into enabled control systems. Integrate your Notifier fire panels into your BACnet
More informationDependable Solutions for Gas Detection
Dependable Solutions for Gas Detection Combustibles/Flammables Standard & Exotic Toxics Oxygen Enrichment/Deficiency Introduction to Sensidyne Established in 1983 - acquired by Schauenburg GmbH in April
More informationSafety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device
Safety Instructions Used symbols Important Comments Before starting with installation of the MS 10B Alarm Unit, we recommend you to read the important information beneath. Qualification The installation
More informationSM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option
SM3000 Videographic Recorder User Guide (RTU) Communications Option ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow
More informationIndustrial Grade Gas Detection Detecting The Difference
detcon inc. Industrial Grade Gas Detection Detecting The Difference PO Box 8067 The Woodlands, TX 77387 888-367-4286 (toll free) 713-559-9200 281-292-2860 (fax) sales@detcon.com Catalog #CB-0409 www.detcon.com
More informationFire and Gas Monitoring Panel ST7-HV
Fire and Gas Monitoring Panel ST7-HV INTRODUCTION TO THE ST7-HV SYSTEM The ST7-HV system is a programmable PLC suitable for safety and security installations with a high technological and economic content
More informationTHERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16
TraceTek TTSIM-1A TraceTek Sensor Interface Module with Relay Installation/OPERATION Instructions Approvals and Certifications TYPE NM General Signaling Equipment 76LJ Only AC versions are UL listed and
More informationStandard Devices. Electronic Alarm Indication Systems. ME 3011b
Standard Devices Electronic Alarm Indication Systems ME 3011b Before connecting and powering this device, please read carefully the manual, and refer to it whenever you have any doubts. This brochure is
More informationACCURATE ELECTRONICS INC
ACCURATE ELECTRONICS INC Page 1 of 7 Model 108078 2 Sept 09 WWW.ACCURATE.ORG PO BOX 1654 97075-1654 8687 SW Hall Blvd 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 Practice Section 108078 Rev A
More informationPROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS
PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min
More informationCONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.
CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse
More informationACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX
Page 1 of 10 Model 10807800 January 2014 ACCURATE ELECTRONICS INC PO BOX 1654 97075-1654 8687 SW HALL BLVD 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 WWW.ACCURATE.ORG Practice Section 10807800
More informationUltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW
12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes
More informationCentaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE
Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE General Description This guide provides a summary for installing and configuring the Centaur TM Cube Slave Alarm Signalling Equipment
More informationDIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers
DIESEL Engine Fire Pump Controllers Features FD120 Diesel Engine Controllers 1-1 March 2013 Diesel Product Description The DIESEL Plus Fire Pump Controllers from Eaton Corporation are designed to control
More informationESSEX ENGINEERING CORPORATION
WATER/WASTEWATER TREATMENT CONTROL SYSTEMS AND SUBSYSTEMS 2000 SERIES CONTROL SYSTEMS: 2000 series are for surface mounting inside a control cabinet Model 2024 Electronic Alternator Duplex (two pump) pump
More informationProcess & TeMPerATUre UniversAl input DigiTAl MeTers
Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min
More informationDigital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6
Digital Gas Transmitters with Auxiliary s & Control Specifications subject to change without notice. USA 181011 Page 1 of 5 DESCRIPTION Digital RS-485 communicating, addressable toxic and combustible gas
More informationM1000 Alarm Annunciator
Data Sheet Alarm Annunciator Reliable Supervision and Control 10 inputs with LED indications Supports both NO/NC input contacts 10 open collector outputs Built-in siren relay Text label for alarm descriptions
More informationSEL-2523 Advanced Annunciator Panel
SEL-2523 Advanced Annunciator Panel Complete Alarm Monitoring, Annunciation, and Communication Major Features and Benefits High Reliability, Low Price Ten-Year, Worldwide Warranty 40 to +85 C Operating
More informationAddressable Fire Alarm Control Panel
PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT
More informationMODEL B2 INSTALLATION MANUAL
RELEASE DEVICES GENERAL DESCRIPTION MODEL B2 INSTALLATION MANUAL S/N: The B2 Series Time Delay Release Devices are UL Listed, Canadian Listed, and CSFM Listed for use on rolling doors, single-slide and
More informationAnnunciator Sequences and Specifications
ANSI/ISA-S18.1-1979 (R1992) Reaffirmed July 13, 1992 American National Standard Annunciator Sequences and Specifications ANSI/ISA-S18.1 Annunciator Sequences and Specifications ISBN 0-87664-346-2 Copyright
More informationSTATUS ALARM HISTORY ALARM RESET
Instruction Manual Model 1582-42L Data Switch February 1999, Rev 0 CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 ONLINE SWITCH RESET MAN
More informationI/A Series 716C 1/16 DIN Temperature Controller
Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of
More information16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5
Construction Standards Page 1 of 5.1 General Description.1 The University requires that all new fire alarm system control panel, components, and devices, as required for the project, be Secutron 2900 Series
More informationPWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R
Region Project Page 1 PART 1 - GENERAL 1.1 REFERENCES.1 CAN/ULC-S524-2006, Standard for the Installation of Fire Alarm Systems..2 CAN/ULC-S525-2007, Audible Signal Device for Fire Alarm Systems..3 CAN/ULC-S526-2007,
More informationINTELLIGENT FIRE ALARM CONTROL PANEL
INTELLIGENT FIRE ALARM CONTROL PANEL FX-2000 SERIES Description Mircom s FX-2000 Series Intelligent Analog Fire Alarm Control Panel is designed to provide maximum flexibility of analog system requirements
More informationSACO 16D3 Annunciator unit. User s manual and Technical description
SACO 16D3 Annunciator unit User s manual and Technical description 1MRS 751354MUM EN Issued 990908 Version A (replaces 34 SACO 16D3 EN1) Checked EP Approved EP SACO 16D3 Annunciator unit Data subject to
More informationINTREPID Perimeter Intrusion Detection System
TM INTREPID Perimeter Intrusion Detection System Next Generation Perimeter Protection icropoint Cable combines patented Southwest Microwave technology with microprocessor power and laptop computer convenience.
More informationAUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET
Instruction Manual Model 1582-125L 1:1 Switch February 2017, Rev. 0 CH1 HISTORY LINE HISTORY RESET AUTO MANUAL SELECT CH2 HISTORY LINE RESET MANUAL REMOTE AUTO PS1 PS2 MODEL 1582 CROSS TECHNOLOGIES INC.
More informationTTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS
TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS GENERAL INFORMATION Please read these instructions and keep them in a safe place. These instructions must
More informationZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL
ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options
More informationwww. ElectricalPartManuals. com Annunciator unit Features Self-contained microprocessor-based annunciator unit with 64 alarm channels Application
Features Self-contained microprocessor-based annunciator unit with 64 alarm channels pplication larm channels activated by normally open or normally closed contact Small and large stand-alone annunciator
More informationTwo-Channel Gas Controller
Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously
More informationGasGard 100 Control System
GasGard 100 Control System Because every life has a purpose... MSA Providing Fixed Gas and Flame Detection Solutions. It is critical for plant managers and personnel to have a proactive and diagnostic
More informationSensor Interface Module Installation/Operation Instructions
TraceTek TTSIM-1 Sensor Interface Module Installation/Operation Instructions Approvals and Certifications TYPE NM General Signaling Equipment 76LJ Only AC versions are UL listed and VDE Certified. For
More informationFlair 500 Series Annunciators
Flair 500 Series s Basics Flair Multi-Zone s (MZAs) are fully functional, flexible, programmable micro controller based alarm control panels. They can be used independently d or in conjunction with other
More informationMODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS
MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS OPERATES ON 12 OR 24 VOLTS AC/DC, AUTO VOLTAGE SENSING FULLY PROGRAMMABLE FROM THE KEYPAD
More informationFIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL
FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL MADE IN THE U.S.A. U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION SERIAL NUMBER The Cookson Company FIREFLY II PLUS Time Delay Release
More informationCommercial and Light Industrial Fire Alarm Control Panel
FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel Features Easily expandable. All new plug-in board design Two supervised audible circuits Lamp and system trouble circuit test Ground
More informationThe system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.
FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001
More informationSpecification/ Data Sheet
Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)
More informationCAREL heatersteam Electric Element Steam Humidifiers
Suggested Engineering Specifications Section 23 84 13 CAREL heatersteam Electric Element Steam Humidifiers 1. GENERAL SCOPE 1. Furnish and install as indicated on the drawings and plans, in-duct [space]
More informationIF-L/RF Protection Switch
Instruction Manual Model 1582-1152 IF-L/RF Protection Switch August 2014, Rev. 0 CH1 HISTORY ALARM LINE HISTORY RESET AUTO MANUAL SELECT CH2 HISTORY ALARM LINE RESET MANUAL REMOTE AUTO ALARM PS1 PS2 MODEL
More informationNGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW
NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The nvent RAYCHEM NGC-40 is a multipoint
More informationGalaxy Pulsar Plus Digital Battery Plant Controller
Galaxy Pulsar Plus Digital Battery Plant Controller Features Supports up to 60 Power Modules rectifiers and converters Supports dual voltage plants, with rectifiers and converters Auto-sensing dual voltage
More informationSECTION AUTOMATIC TRANSFER SWITCHES
SECTION 26 36 23 AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationWindow facia fault annunciators
Window facia fault annunciators WAP Window Annunciator Panel 15.08.2017 Annunciators for panel mounting with 24 signal inputs Storage of the last state of inputs and sequence in the case of power failure
More informationelite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems
5/25/16 rev 6 elite Model ELN General Specification 550 W to 1.5 KW elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems 1.0 General General Specification This specification
More informationTrueAlarm Fire Alarm Systems
OPERATOR OPERATOR OR TROUBLE CONDITION: TO : FIRE PRIORITY 2SYSTEM SYSTEM SIGNALS POWER INDICATOR. SUPERVISORYTROUBLE SILENCED ON D. TO SILENCE SIGNALS: - PRESS " SILENCE". SUPV TBL SYSTEM ACK ACK ACK
More informationNov 08 PRODUCT SPECIFICATION SHEET
Honeywell UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 Nov 08 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL
PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Minimum lighting control (base scope of work) shall include all corridors. The lighting in all the corridors shall be turned on (if not already on) if
More informationNGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3
NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The Raychem NGC-40 is a multipoint electronic
More informationTHE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL
S S S S S S S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED U 99Y9 RESET L RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE
More informationACTIVE INFRARED BARRIER
Although PROTECH provides high security indoor intrusion sensors for the military and government markets, our specialty is outdoor protection. Since we first introduced our PIRAMID outdoor dual technology
More informationINSTALLATION INSTRUCTIONS
TT-1343 5/06b INSTALLATION INSTRUCTIONS Original Issue Date: 8/03 Model: Automatic Transfer Switches Equipped with Series 1000 Programmable Controller Market: ATS Subject: Remote Annunciator Kits GM28938-KP1,
More informationRELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:
RELEASE DEVICES MADE IN THE U.S.A. RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION: S/N: The "WPS" World Power Series, Time Delay Release
More informationCTT8 TEMPERATURE MONITOR DEVICE
INSTRUCTION MANUAL IM302-U v2.3 CTT8 TEMPERATURE MONITOR DEVICE GENERALITY The device of control temperatures CTT8 is used in the control of electric machine, transformer, motor, etc. where it s possible
More informationBurner Company. Flame Safeguard Systems. Bulletin IG-1. Bulletin FS-1
Burner Company Flame Safeguard Systems Bulletin IG-1 Bulletin FS-1 Flame Safeguard Systems Flame Safeguard Model Identification (Example of a typical spec): FSG - E110/E300 - UV - NFPA/IRI/FM - W3 - FC
More informationRELEASE DEVICE CONTROLS
RELEASE DEVICE CONTROLS RELEASE DEVICE MODEL C+ INSTALLATION MANUAL UL LISTED CANADIAN LISTED CSFM: 7300-48:00 GENERAL DESCRIPTION: MADE IN THE U.S.A. S/N: The LM0-C+ Release Device/Control Panel is a
More informationINDUSTRIAL GRADE WATER SOFTENERS LWT INDUSTRIAL SERIES
INDUSTRIAL GRADE WATER SOFTENERS LWT INDUSTRIAL SERIES 1,200,000 TO 3,000,000 GRAINS CAPACITY WATER SOLUTIONS * CUSTOM ENGINEERING * INDUSTRIAL PERFORMANCE (Single, Twin, Triple or Quadruple Demand Systems)
More informationTYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM
2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40
More informationRS485 MODBUS Module 8AI
Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationModBus DE-1 INSTALLATION AND USER MANUAL
ModBus DE-1 INSTALLATION AND USER MANUAL INTESIS Software, SL Distributed by DURAN ELECTRONICA S.L Tomás Bretón 50 28045 MADRID, España duran@duranelectronica.com www.duranelectronica.com 2 2010 DURAN
More information