Automatic Waste Water Lifting Unit
|
|
- Dustin Sharp
- 5 years ago
- Views:
Transcription
1 Type Series Booklet /4-EN Ama r -Drainer-Box 021 Automatic Waste Water Lifting Unit Above-floor-Box 021 Fields of Application Single Lifting Unit - Above-floor Box 021 F Automatic drainage of wash-basins, showers, washing-machines, etc. Medium Handled Standard Variant - Particle Size 10 mm Slightly contaminated water, also containing solid particles with aparticlesizeofupto10mm. For aggressive water, use Ama-Drainer C variant. Ama-Drainer-Box is not suitable for sewage from urinals and toilets. For these applications please use our mini-compacta/ Compacta sewage lifting units. Operating Data Standard Variant Q H t Above-floor Box 021 (25 l) upto8m 3 /h, 2.2 l/s up to 6.5 m up to 35 C 1 ) Anlagen mit größeren Leistungen siehe Baureihenheft Ama-Drainer-Box EN. 1 ) Up to 3 minutes for waste water from hot water cycle of washing-machines and dish washers for non-industrial use. Designation Type series Collecting tank 021 = Code number for Ama-Drainer here Ama-Drainer C = Variante für aggressive Medien Design / Variant C Above-floor Box 021: Stable plastic collecting tank with submersible motor pump starting and stopping automatically. DN 50 connection on the suction side, DN 40 connection on the discharge side and integrated swing check valve. Materials Tank Pump -- EN Überflur-Box 021 Acrylonitrile-butadiene-styrene copolymer (ABS) see Ama-Drainer Type Series Booklet CE -- EN
2 Single Lifting Units - Above-floor Box :509 Single Lifting Units (Complete) - Above-floor Box 021 Ama-Drainer-Box Ama-Drainer P 2 50 Hz Power supply Ident. No. cable 1~ V 3~ V H 07 RN-F.G. kw I N A I N A m mm 2 kg ) Above floor 301 SE x /C 1 ) 301 SE/C x ) Supplied completely assembled ex works 2
3 Standard Variant Above-floor Box 021 Inlet A DN 50 pipe (rubber socket) A Connection to washing-machine, horizontal or vertical via Y-drain pipe Inlet B Connection to shower: special pipe part DN 50 (outside Ø 50) as accessory Discharge side C DN 40 pipe (rubber socket) Venting D Carbon filter insert with overflow protection Wherever possible, we recommend to lead the vent pipe out of the roof (max. outside pipe diameter: 40). for floor or wall mounting Connection to shower (accessory) Anti-rotation device 1 ) Switching levels, standard variant 2 ) Switching levels, variant for shower facilities with special float Installation Schematic - Above-floor Box 021 Backwash level Discharge line In case of water levels above the backwash level, a gate valve should be installed on the discharge side. 3
4 Product Features to Our Customers Benefit Above-floor Box 021 Discharge line on the left or right on option; other connections possible on all sides, for example to shower facilities, washing-machine, etc. Great flexibility of piping connection Integrated swing check valve Prevents drainage of the discharge line Pressure-sealed casing of ABS D No bad odours D Thermal and dimensional stability D Fully recyclable Modern low-height design Can be connected directly below the wash-basin -- looks better Extremely smooth, wall-mounted tank D Easy-care surface D Wall- mounting facilitates floor cleaning Venting on option through the roof or through activated carbon filter with integrated overflow protection device D No overflow risk Ready-to- connect mini pumping station D Easy and fast installation D DN 40 and DN 50 connection diameters with self-sealing rubber socket are available Powerful, maintenance-free submersible motor pump Reliable, trouble-free operation 4
5 Accessories Ama-Drainer-Box 021 Shower connection set for above-floor box kg all M 1 alarm contactor Magnetic float switch as contactor for alarm switchgears AS 0, AS 2, AS 4 and AS 5; with 5 m power supply cable Alarm switchgears Alarm switchgear AS _ 230 V~/ with circuit breaker, piezoceramic signal transmitter, 12 V = 85 db(a) at a distance of 1 m and 4.1 khz, 1.2 VA green equipment-on lamp Plastic housing IP 20, 140 x 80 x 57 mm Use float switch (item E 60), moisture sensor F 1 (item E 64) or M 1 alarm contactor as contactor. Ama-Drainer-Box Ident. No. E50 mains-dependent AS 0 X kg E51 mains-dependent AS 2 with volt-free signalling contact E52 mains-independent AS 4 with volt-free signalling contact, self-charging power supply unit for 5 hours operation in case of a mains failure E53 AS 5 alarm switchgear, mains-independent, 230 V~/ with self-charging power supply 12 V = unit for 10 hours operation in case of 5 VA a mains failure, mains pilot LED, fault indicator lamp, horn-off push button, volt-free contact for hook-up to a control station, ready to be plugged in, with 1.8 m cable and plug. X X X ISO housing IP 41, 190 x 165 x 75 mm Use float switch (E 40) as contactor. Horn see accessories E55 AS 1 alarm switchgear, 230 V~/ in ISO plug housing IP 30, mains-independent, 9 V= with self-charging power supply unit for 5 hours 1.5 VA operation in the case of mains failure, acoustic signal 70 db(a) with circuit breaker and integrated signal transmitter with 3 m connection cable. X E 330 Possible application for alarm transmission: Water alarm signal at a water level of only 1 mm (!), by placing the contactor on the floor of rooms at risk of flooding, e.g. the cellar or next to the washing machine in the kitchen or bathroom. KSB washing machine interrupter Alarm triggered, with automatic interruption of power supply to the washing machine if the water level in the collecting tank is too high 230 V AC, 50/60 Hz, max. 16 A resistive load Comprises: -- Housing with socket and plug -- Buzzer -- Automatic re-start -- Contactor with 5 m connection cable X ,7 5
6 Electric Accessories E64 Moisture sensor F 1, as contactor for alarm switchgear AS 0, AS 2 or AS 4, with 3-metre connection cable, max. 40 C, not suitable for steam and condensate. Possible application for alarm transmission: Water alarm signal at a water level of only 1 mm (!), by placing the contactor on the floor of rooms at risk of flooding, e.g. the cellar or next to the washing machine in the kitchen or bathroom. 52 x 21 x 20 mm E70 Horn suitable for indoor and outdoor installation, 12 V= mount in a position where it is protected against direct rain, 105 db(a) enclosure IP W Ama-Drainer-Box Ident. No. kg X ,9 X
7 7
8 /4-EN / Subject to technical modifications without prior notice.
Automatic Waste Water Lifting Unit. Ama-Drainer-Box Mini. Type Series Booklet
Automatic Waste Water Lifting Unit Type Series Booklet Legal information/copyright Type Series Booklet KSB Aktiengesellschaft Pegnitz All rights reserved. Contents provided herein must neither be distributed,
More information50 Hz. Submersible Waste Water Pumps
Type Series Booklet 2337.51--10 Ama-Drainer r N 301/302/303 Submersible Waste Water Pumps 50 Hz Ama-Drainer R N 301 Ama-Drainer R N 302 Ama-Drainer R N 303 Applications F Automatic drainage of pits, shafts,
More informationmini-compacta Type Series Booklet
Floodable Sewage Lifting Unit 60 Hz Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,
More informationSubmersible Waste Water Pump. Ama-Drainer N 301/302/ Hz. Type Series Booklet
Submersible Waste Water Pump Ama-Drainer N 301/302/303 60 Hz Type Series Booklet Legal information/copyright Type Series Booklet Ama-Drainer N 301/302/303 All rights reserved. The contents provided herein
More informationSubmersible Waste Water Pump. Ama-Drainer N 301/302/303/358. Type Series Booklet
Submersible Waste Water Pump Ama-Drainer N 301/302/303/358 Type Series Booklet Legal information/copyright Type Series Booklet Ama-Drainer N 301/302/303/358 All rights reserved. The contents provided herein
More informationLifting Plants Product Overview
Wilo-DrainLift Con Duty chart (-pole, 5 Hz) 5 Wilo-DrainLift Con Lifting Plants Product Overview Wilo-DrainLift Lifting Plants Condensate lifting plants Removal of condensate, can be used in Condensing
More informationSekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS
Sekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS Wastewater is a demanding process, performance, day in day out. Xylem challenges, providing trusted
More informationGRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz
GRUNDFOS DATA BOOKLET Unilift CC, KP, AP Submersible drainage and effluent pumps 50 Hz Contents Product overview General data Performance range 4 Applications 5 Examples of applications 5 Pump overview
More informationCleaning System. Amajet. Type Series Booklet
Amajet Type Series Booklet Legal information/copyright Type Series Booklet Amajet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed
More informationMULTISAN Fully automatic sewage and waste water pump
MULTISAN Fully automatic sewage and waste water pump Multisan is suitable for pumping waste water from toilets, bidets, showers and basins from rooms which are below the sewer level, or conditions where
More informationGRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz
GRUNDFOS DATA BOOKLET Unilift CC, KP, AP Submersible drainage and effluent pumps 50 Hz Contents Product overview Unilift CC, KP, AP 3 General data Performance range 4 Applications 5 Examples of applications
More informationOwners Manual for the Rainmaster Water Recycling System
Owners Manual for the Rainmaster Water Recycling System 22874 Manual.indd 1 4/8/05 8:45:05 AM Rain Master Water Recycling System Welcome! Thank you for purchasing a Rainmaster Water Recycling System. Your
More informationGRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz
GRUNDFOS DATA BOOKLET Unilift CC, KP, AP Submersible drainage and effluent pumps 50 Hz Contents Product overview General data Performance range 4 Applications 5 Examples of applications 5 Wastewater definitions
More informationLS Condensate Removal Pump INSTRUCTION MANUAL REVISION A
LS Condensate Removal Pump INSTRUCTION MANUAL 6-71-075-115 REVISION A CAUTION: Combustible liquids may not be pumped! The condensate pump may not be run dry, as this can destroy the bearings in a very
More informationTechnical data. Unilift KP. CRUNDFOS "~ ozpump.com.au Drainage pumps. Unilift KP
Pumped liquids The pump is suitable for clean, non-aggressive water slightly dirty (grey) wastewater. The open-impeller construction ensures the free passage of solids up to 00 mm. Functions -5 Automatic
More informationTrusted Expertise in Domestic and Commercial Wastewater
Trusted Expertise in Domestic and Commercial Wastewater Any Project, Any Wastewater Application Wastewater poses a complex challenge, no matter whether it originates in a single house or a multifamily
More informationINFO 3/2015. NEWS WC connectors Bronze program Industrial stainless steel drainage system Swimming pool overflow radius gratings.
INFO 3/2015 www.alcaplast.com S WC connectors Bronze program Industrial stainless steel drainage system Swimming pool overflow radius gratings WC CONNECTORS flexible cuff to connect the outlet and WC pans
More informationRC411 Operator Manual
RC411 Operator Manual Page 1 of 14 FOREWORD 1. Read the instructions contained in the enclosed booklet carefully, because it contains important information on installation, operation and maintenance safety.
More information30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw
Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The
More informationOwners Manual For The Rainmaster Water Recycling System
Owners Manual For The Rainmaster Water Recycling System Owners Manual.indd 1 4/8/05 8:58:36 AM Rain Master Water Recycling System Welcome! Thank you for purchasing a Rainmaster Water Recycling System.
More informationProcess engineering. Collection and disposal of commercial food waste ACO Waste-Jet Wet refuse collection system
Collection and disposal of commercial food waste ACO Waste-Jet Wet refuse collection system ACO. The future of drainage. The ACO system chain provides drainage solutions to meet tomorrow s environmental
More informationAlarm Switchgear AS1-M
Installation, Operating and Maintenance Instructions 1/7 Installation, Operating, and Maintenance Manual for Alarm Switchgear AS1-M These installation, operating and maintenance manual must be handed to
More informationJUNG PUMPEN LIFTING STATIONS
JUNG PUMPEN LIFTING STATIONS POWERFUL AND DEPENDABLE RESIDENTIAL TECHNOLOGY LIFTING STATIONS Product overview: Lifting stations the full range: Lifting stations are designed to dispose of wastewater in
More informationLS Condensate Removal Pump Installation, Operation and Service Instructions
Bell & Gossett Instruction Manual 6-71-075-115 LS Condensate Removal Pump Installation, Operation and Service Instructions INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. WARNING: This safety
More informationBrochure EX
BRISE Brochure 2012-2013.EX BRISE Super-power for heating, cooling and ventilation. Brise keeps a tight rein on temperatures and is full of energy, controlling your interior climate with precision through
More informationINSTALLATION AND OPERATING INSTRUCTIONS
INSTALLATION AND OPERATING INSTRUCTIONS KESSEL Grease Separator G, D and D+S versions Certified under Euro-Norm EN 1825-1 For free standing installation in frost free areas KESSEL Grease separators G,
More informationInstruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!
Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 74363 Güglingen Telefon +49 7135-102-0 Service +49 7135-102-211 Telefax +49 7135-102-147 info@afriso.de
More informationSUBMERSIBLE PUMPS For water with particulate matter 2 pole - 50 Hz 2 ranges : SS 304 & SS 316 L
operating limits Flow up to: m /h Head up to: m w.g. Liquid temperature range: + to 5 C* Specific gravity of liquid:.5 max. ph of liquid: - Max. immersion depth: m Free passage: Ø mm ND of discharge port:
More informationInstruction Manual. Electronic gas and smoke detector GRM
Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 DE-74363 Güglingen Telefon +49(0)7135-102-0 Service +49(0)7135-102-211 Telefax +49(0)7135-102-147 E-Mail
More informationCRU 200 and 500 Series Condensate Recovery Units
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationUPZ PUMP POWER FOR TOP PERFORMANCE UNDER
Submersible borehole pump People at KSB we make your world flow round! UPZ PUMP POWER FOR TOP PERFORMANCE UNDER THE TOUGHEST CONDITIONS UPZ is top choice wherever submersible borehole pumps have to satisfy
More informationBRISE. Super-power for heating, cooling and ventilation.
BRISE 2016-2017.EX BRISE Super-power for heating, cooling and ventilation. Brise keeps a tight rein on temperatures and is full of energy, controlling your interior climate with precision through the range
More informationUSER S MANUAL DN-2. Drain pump
USER S MANUAL DN-2 CONTENTS Safety requirements... 2 Purpose... 3 Delivery set... 3 Technical data... 3 Design... 4 Installation and set-up... 5 Connection to power mains... 8 Storage and transportation
More informationBuilding Services. KSB Building Services. A Real Welcome Home.
Building Services KSB Building Services. A Real Welcome Home. 2 Introduction Build the future with KSB. Whether you earn your living by installing or selling pumps, valves and systems, or want to make
More informationNEWS 2017 SANIFLO. Pumps and pumping stations
NEWS 2017 SANIFLO Pumps and pumping stations SFA, WORLD LEADER IN SANITARY FACILITIES MADE IN FRANCE For 60 years, the Société Française d Assainissement [French Sanitation Company] has worked on improving
More informationThe easy solution for waste water removal
The easy solution for waste water removal Wasteflo products provide a solution for waste water removal in a variety of environments. Full technical data sheets are available to download www.stuart-turner.co.uk
More informationHYDROCIAT LW R407C. Water cooled chillers USE RANGE
Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT
More information3. Before switching the equipment on, make sure that the model plate data conforms to that of the electrical and water distribution network.
Manuale di istruzione per lavastoviglie Notice d utilisation pour lave-vaisselle Gebrauchsanweisung für Geschirrspüler Instruction manual for dishwashers Manual de instrucciones para lavavajillas LF315
More informationFEATURES. Other Fed-Flush Arrangements
Brochure # 0710 TYPE TYPE... VSAF SEWAGE EJECTOR SYSTEM Flows to 600 gpm, Heads to 120, 1 thru 40 HP. Discharge size 4, 1750 and 1150 RPM, strainer in discharge pipe. HIGHLIGHTS Installations where rags
More informationComfort Odour free Easy handling. Waterless. Environmentally friendly. Feels like home. Comfort wherever you are.
Comfort Odour free Easy handling Waterless Environmentally friendly Feels like home Comfort wherever you are Separett VILLA 5-year guarantee www.separett.com Separett a complete toilet system for vacation
More informationRL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw
The RL/1 burners series covers a firing range from 107 to 398 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Optimisation
More informationAirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation
mfh systems modern floor heating AirUnit Decentralised domestic ventilation Installation instructions List of contents, Installation instructions Page 1. General information... 03 2. Function / planning
More informationSUPPLEMENTARY INSTRUCTIONS
www.burcam.com 2190 Dagenais Blvd.West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com SUPPLEMENTARY INSTRUCTIONS MODEL 450475 Dear consumer, We thank and congratulate
More informationPUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:
PUDDLE PUMP PUDDLE PUMP MODEL No: PSP125 Part No: 7230692 OPERATION & MAINTENANCE INSTRUCTIONS 1007 SPECIFICATIONS Model number... PSP125 Rated voltage... 230VAC 50Hz Input power... 293 Watts Maximum delivery
More informationTYPE POS Oil Shield Sump Pump
Type POS Oil Shield Provides protection for the environment by preventing oil products from entering sewer systems, environmentally Sensitive River and waterways, while protecting equipment and areas from
More information~256. Ventilator. Float valve. Plugged end (INLET) Straight connection DN kpa: 1.20 l/s (instantaneous value)
Date: 05 May 2009 Doc. 002190-2 TECHNICAL DATA 6543521 UNIT 2L, CONNECTION UPWARDS Mini-check Straight connection DN50 Rubber bend DN40 Connection DN40 83 ~195 35 Max. 3m ~256 Ø90 Evac Noback OUTLET Discharge
More informationLifting Station Type ABS Sanimax
1051-00 15970278EN (11/2015) EN Installation and Operating Instructions www.sulzer.com 2 Installation and Operating Instructions (Original Instructions) : R 202 MF 154 R 202/C MF 154HW MF 324 Contents
More informationZeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017
Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air
More informationPOWER and INTELLIGENCE
POWER and INTELLIGENCE Lifting stations The new lifting station Aqualift F Compact - Sewage lifting station complete basement drainage installation in a slab/floor and free-standing installation Leading
More informationFeels like home. Unlimited Capacity Odour free Easy handling Waterless. Comfort wherever you are. Environmentally friendly
Unlimited Capacity Odour free Easy handling Waterless Environmentally friendly Feels like home Comfort wherever you are Separett VILLA 5-year guarantee www.separett.com 5-year guarantee Child Seat Included
More informationFUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED
FUEL OIL DAY TANKS SST Series - Engineering Submittal SST Series - Advanced Line Day Tanks Construction: UL 142 aboveground steel tank all seam welded, square, atmospheric tank of heavy gauge steel with
More informationInstructions for the fan motor control system, SILVER C
Instructions for the fan motor control system, SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units. The motor control system is
More informationREGISTRATION EXAMINATION, NOVEMBER 2014 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours
Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 9192 REGISTRATION EXAMINATION, NOVEMBER 2014 LICENSED PLUMBER INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time
More informationRAINWATER FILTERS AND REUSE OF RAINWATER
RAINWATER FILTERS AND REUSE OF RAINWATER Rainwater filters to install in front of the tank Rainwater filters to install in the tank Rainwater pumps to install in the house Rainwater pumps to install in
More informationSOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59
SOUND-INSULATED FAN OPERATION MANUAL _v.1(2)-en.indd 1 10.08.2015 15:20:59 CONTENT Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 3 Fan design 4 Delivery
More informationGRUNDFOS PRODUCT GUIDE. Unilift CC, KP, AP. Submersible wastewater pumps 60 Hz
GRUNDFOS PRODUCT GUIDE Submersible wastewater pumps 60 Hz Contents Mission Product overview, Unilift General data, Unilift Performance range 6 Applications 7 Type keys 8 Construction 9 Unilift CC Product
More informationABS lifting station Sanimax
105100 15970278GB (09/2011) GB Installation and Operating Instructions www.absgroup.com Installation and Operating Instructions (Original Instructions) R202 R202/C MF154 MF324 Contents 1 General... 3 1.1
More informationInstructions for use PHPC 6.4F AM X
EN English, 7 Instructions for use PHPC 6.4F AM X 2 3 4 5 6 English GENERAL SAFETY Before any cleaning or maintenance operation, disconnect hood from the mains by removing the plug or disconnecting the
More informationInstallation instructions Danfoss heat pump DHP-R
Installation instructions Danfoss heat pump DHP-R Table of contents DHP-R 1 Important information........................................................... 5 1.1 Refrigerant...5 1.2 Noise and vibrations...5
More informationSL EX.4.51D
GRUNDFOS DATA BOOKLET SL1.1.1.75.EX.4.51D Grundfos pump 962669 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/sl1/962669/sl1-1-1-75-ex-4-51d-c.html
More informationHYGIENE EQUIPMENT INTRODUCTION HYGIENE
EDITION 2015/2016 INTRODUCTION HYGIENE EU directive 64/433 introduced in the food plants the obligation to produce food in a safe way. To meet the requirements regarding hygiene for staff, machinery, equipment
More informationAerFlow at ::rangehoods.com is a division of kitchen::accessories U N L I M I T E D
USA COOKER HOOD USER INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS EFORE PROCEEDING. IMPORTANT: Save these Instructions for the Local Electrical
More informationGRUNDFOS INSTRUCTIONS MSS, MLD. Installation and operating instructions
GRUNDFOS INSTRUCTIONS MSS, MLD Installation and operating instructions Declaration of Conformity We Grundfos declare under our sole responsibility that the products MSS and MLD, to which this declaration
More informationCooking c o l l e c t i o n
Cooking c o l l e c t i o n Instructions for Use and Warranty Details RH60-600mm Fixed Rangehood RH90-900mm Fixed Rangehood ongratulations on the purchase of your new C appliance. This appliance has been
More informationINSTALLATION FB T: +44 (0) F: +44 (0) E: W:
INSTALLATION FB 1 Contents User instructions General Fan installation Maintenance Electrical installation Troubleshooting Technical description General Classification Technical specification Manufacturer
More informationDec Wirsbo CoSy Radio. Installation and Operating Instructions
Dec. 2002 Wirsbo CoSy Radio Installation and Operating Instructions Contents 1. Overview... 3 2. Room thermostat... 3 2.1 Thermostat models... 3 2.2 Function... 4 2.3 Positioning... 4 2.4 Setting and limiting
More informationComfort. Odour free Easy handling. Waterless. Environmentally friendly. Feels like home. Comfort wherever you are.
Comfort Odour free Easy handling Waterless Environmentally friendly Separett FLAME 3-year guarantee Feels like home Comfort wherever you are Separett VILLA 5-year guarantee www.separett.com Separett a
More informationPump WaterVISE, FloVISE
General information It is important that this manual is read carefully by the user and the installer in order to ensure proper functioning and lifespan of the pump. Pahlen pumps are manufactured in accordance
More informationTP /4-A-F-A-BQQE 400D 50HZ
GRUNDFOS DATA BOOKLET TP 15-7/-A-F-A-BQQE D 5HZ Grundfos pump 989838 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/989838/tp-15-7--a-f-a-bqqe.html
More informationWATER, OIL, CONTAMINANTS: SEPARATION AND EVACUATION
drains SEPARATORS, BLEED VALVES AND PROCESSING UNITS WATER, OIL, CONTAMINANTS: SEPARATION AND EVACUATION Condensates collected by filtration or separation along the air network must be quickly and effectively
More informationINSTALLATION GUIDE NZ AU
DISHWASHER DW60U6I & DW60U2I models INSTALLATION GUIDE NZ AU 1 SAFETY AND WARNINGS 100 lb 45 kg! WARNING! Electrical shock hazard Before installing the dishwasher, remove the house fuse or open the circuit
More informationHood Type Combi Dishwasher WD-90 DUO. wit h
Hood Type Combi Dishwasher s e l u n a gr wit h OUR NEW CHALLENGER YOUR NEXT CHOICE For a flexible flow of dishware Wexiödisk s HOOD TYPE COMBI DISHWASHER with plastic granules clean effectively and ensures
More informationGreenleaf 600 Macerator Toilet Waste Pump
Greenleaf 600 Macerator Toilet Waste Pump Website: Contact: www. greenleaftrade.co.nz Introduction The Greenleaf 600 toilet macerator waste pump is suitable for use in domestic waste / sewerage installations.
More informationCombiBloc Close-coupled centrifugal pumps
CombiBloc Close-coupled centrifugal pumps CombiBloc CombiBloc is the premier solution for pumping clean thin liquids in a very cost-effective way. The pump is part of Johnson Pump s Combi-system, a modular
More information> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories
> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base
More informationPilot devices Stacklights Signal beacons
Pilot devices Fast mounting of signal elements using bayonet fixing Easy changing of bulbs for each module without tools Up to 10 light elements possible with 2-sided mounting bracket Flexibility of signal
More informationLicht und Spiegel # LM 9642
Leben im Bad Living bathrooms Licht und Spiegel # LM 964 Installation instructions 350 6,5 5 6,5 350 5 6,5 6,5 80-780 350 / S8 5 0 5,5x50 Instructions for use The bathroom furniture range complies with
More informationTECHNICAL SPECIFICATION
VALLOX-product code: HVAC code: 358500 L 35850 R 79076 L 79077 R SOUND ATTENUATOR (OPTIONAL) IVALLOX 252 WATER OPERATED POST- HEATING UNIT (OPTIONAL) ELECTRICAL POST-HEATING UNIT (OPTIONAL) ELECTRICAL
More informationWISY. Rainwater Harvesting. Installation and Operating Instructions. English. instructions for the. rainwater units. these installation
ion Instructions Installation Instructions Installation I English ons Installation Instructions Installation Instructions ion Instructions Installation Instructions Installation I ons Installation Instructions
More informationELECTRIC PASTA COOKERS
OPTIMUM 700 & 900 ELECTRIC PASTA COOKERS BUILDER S SPECIFICATIONS Part A: Technical characteristics Part B: Technical instructions for the installer - WARNING - Installation and repairs must be carried
More informationT-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N
T-SERIES Air Conditioner T29 Model INSTRUCTION MANUAL Rev. I P/N 89104464 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE
More informationCondensate water pumps
Condensate water pumps Welcome! If reliability is your main concern, then you finally have the right document in your hand. Among our big range of condensate pumps you will certainly find the one matching
More informationEHT10 Electric Hot Water Tap
watersave Catalogue EHT10 Electric Hot Water Tap Hot water in your kitchen at the turn of a tap without the need for storage! Product Code: EHT10 Features include: EHT10 Electric Hot Water Tap Specification
More informationPROPERTY REINSPECTION REPORT
PROPERTY REINSPECTION REPORT Prepared For: Andrew Xia Address: 1078 Great Meadow Dr. Allen, TX 75013 By: Robert Taylor, TREC license # 3619 Date: 10/27/2014 The Three Page Visual Contract Agreement previously
More informationMillo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A
Millo / Millo pro Nr. 1804-x000 / 1805-x000 0609 21-6543 A Ideen für die Dentaltechnik 1 2 3 4 5 6 7 8 9 10 11 12 Millo / Millo pro No. 1804-x000 / 1805-x000 ENGLISH Content Introduction... 15 Symbols...
More informationRhima Deko 190 Washer-disinfector for human waste containers
Rhima Deko 190 Washer-disinfector for human waste containers MEETING THE STANDARDS The DEKO 190 is designed and constructed to meet the standard performance and design requirements stated in ISO 15883-1
More information1 WATERMARK CERTIFICATION SCHEME SCHEDULE OF PRODUCTS This document was adopted 1 August 2017 and replaced the WaterMark Schedule of Specifications
1 WATERMARK CERTIFICATION SCHEME SCHEDULE OF PRODUCTS This document was adopted 1 August 2017 and replaced the WaterMark Schedule of Specifications Product type Application Specification Appliances Bedpan
More informationCR A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR45-12-2 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 96122818 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96122818/cr-45-12-2-a-f-a-e-hqqe.html
More informationElectric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features
Electric Pumps Introduction W4100, W4200 & W4300 Condensate Pumps Watson McDaniel s Condensate Return and Boiler Feed Pumps are equipped with Cast Iron bodies and Bronze Impellers. The pump receiver tanks
More informationDewatering Solutions for the Real World In the real world time is money, and worksites have no time for unwanted water. Sulzer has the solutions in a
2 Dewatering Solutions for the Real World In the real world time is money, and worksites have no time for unwanted water. Sulzer has the solutions in a complete pump range for reliable dewatering. This
More informationSpecifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1
Specifications Rated voltage (V) AC 110-120V or 220-240V / 50-60Hz Vacuum motor power consumption(w/hp) 1200 / 1.6 Exhaust water pump power consumption(w/hp 800 / 1.1 Exhaust water pump flow (GPH/LPH)
More informationGRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz
GRUNDFOS DATA BOOKLET Grundfos booster systems with two or three CM, CMV or CR pumps 50 Hz Table of contents 1. Product introduction 3 2. Performance range 4 with CM pumps 4 with CMV pumps 4 with CR pumps
More informationPROFESSIONAL HAIR STYLER
PROFESSIONAL HAIR STYLER HS 8980 ENGLISH A 2 B C D G E F 1 3 4 5 2 ENGLISH SAFETY Please note the following instructions when using the appliance. 7 This appliance is intended for domestic use only. 7
More informationThe Hood Type Concept
The Hood Type Concept BECAUSE WE DO CARE The new green Hood Type Concept saves more than just water... Wexiödisk introduces an innovative and environmentally friendly solution for your dishwashing operation.
More informationcondensate pumps For air conditioning and refrigeration technology eckerle.com
condensate pumps For air conditioning and refrigeration technology eckerle.com Condensate pumps in air conditioning technology Condensation is the change of state of the physical state of matter from gas
More informationSL S.S.N.51D
GRUNDFOS DATA BOOKLET SL1.8..265.2.52S.S.N.51D Grundfos Pump 9814549 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/seslfam/9814549/sl1-8--265-2-52s-s-n-51d.html
More informationOperation Manual. Trash Water Pump ARTICLE Image similar
Operation Manual Trash Water Pump ARTICLE 50781 Image similar Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Due to further
More informationInstruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data
Instruction manual Submersible sump pump Safety instructions Application Electrical connection Installation Maintenance Technical data U 3 K /2 U 3 KS /2 U 3 K spezial /2 U 3 KS spezial /2 U 5 K /0 U 5
More informationMODEL INSTALLATION INSTRUCTIONS GRINDER PUMP
www.burcam.com 2190 Dagenais Blvd. West LAVAL (QUEBEC) CANADA H7L 5X9 TEL: 514.337.4415 FAX: 514.337.4029 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.
More informationINLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL
INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL CONTENT 3 Introduction 3 General 3 Safety rules 3 Storage and transportation rules 3 Manufacturer s warranty 4 Fan design 4 Delivery set 5 Technical data
More information