1 SIEMENS Data Sheet Fire Safety & Security Products '08 Series Notification A liances AS I AH & AS - Audible Strobe Appliances and AH Audibles AS-MC-CW AS-MC-R AH-W AH-R Product Overview - Fast installation with In I Out screw terminals using #12 to #18 AWG wires - Synchronization can be accomplished using the Siemens DSC sync modules, FS-250 panel, XLS panel, MXL panel, or PAD-3 power supply with built-in sync protocol - 3 Selectable dba settings of dba Anechoic in both tones - Selectable Continuous Horn or Temporal (Code 3) - Wall mounts are available with field-selectable Candela settings: 15/30/75111 Ocd or 135/185cd - Ceiling-mount models are available with field-selectable Candela settings: /95cd or cd (multi-candela ceiling models) AS R - WP: - Weatherproof models are available for outdoor use - UL Listed & ULC Listed; FM, CSFM & NYMEA Approved - ADA I NFPA I UFC I ANSI compliant Specifications AS = AUDIBLE STROBE 75 = 75cd CURRENT RATING R = RED HOUSING WP =WALL-MOUNT - Notification appliances shall be Siemens Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals - Series AS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired for Indoor Fire Protection Service) - Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling) - All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by the Fire Alarm Control Panel (FACP) - The audible portion of the appliance shall have a minimum of three (3) field-selectable settings for dba Anechoic levels, and shall have a choice of continuous or temporal {Code 3) audible outputs - Strobe portion of the appliance shall produce a flash rate of one ( 1) flash per second over the Regulated Input Voltage Range, and shall incorporate a Xenon flashtube enclosed in a rugged Lexan lens SIEMENS Industry, Inc. Building Technologies Division '08 Series Notification Appliances

2 Specifications- (continued) - Series AS shall be of low-current design Strobe intensity, where Multi-Candela appliances are specified, shall have field-selectable settings, and shall be rated per UL Standard 1971 for: 15/30/75/11 Ocd 135/185cd The appliance, when synchronization is required, shall be compatible with Siemens' DSC Sync Modules or Siemens PAD-3 Power Supplies with built-in Siemens Proprietary Sync Protocol The strobes shall not drift out of synchronization at any time during operation The strobes shall revert to a non-synchronized flash-rate, if the sync module or Power Supply should fail to operate (i.e.- contacts remain closed) The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Siemens synchronization The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 1 OOmm European type backboxes, or the SHBBS Surface Backbox All notification appliances shall listed for Special Applications: Strobes are designed to flash at 1-flash-per-second minimum over their "Regulated Input Voltage Range» Note: NFPA-72 specifies a flash rate of 1-to-2 flashes per second, and ADA Guidelines specify a flash rate of 1-to-3 flashes per second All Candela ratings represent minimum-effective Strobe intensity, based on UL Standard 1971 Mounting Diagram 4 (Shown In Inches) (Shown In Inches) Mounting Options SIEMENS Industry, Inc. Building Technologies Division

3 Technical Data Desctiptlon Model" Contioooos Hom 91 AS-MC *Available in red and white Code3 Hom or \4arch Time~ 69 '*Available in sync mode 011/y Notes: 1. Strobe will produce 1 flash per second over the Input Voltage range. 2. This strobe/horn model meets the required light distribution patterns defined in UL This model is UL Listed for indoor use with a temperature range of +32 F to+ 120 F (0 C to +49 C) and maximum humidity of 93% + 2% RH. The effect of shipping and storage temperatures shall not adversely affect the performance of the appliance when it is stored in the original cartons and not subjected to misuse or abuse. tvlodel AH DC FWR )esctiption ULC Usred Models & Rallngs Maximum RMSCUrrent Lo Med UL Reverl>erant [Per UL Ft] so &0 Continuous Hom &0 & & &0 Code 3 Hom or Medium &0 &5 Vfarch Time.. High & ~ULC Current Rafillgs!for Model AH) cib.it 48 degrees eft 41-6 db.a.: 50 :eft, 58 c rees Note: All models are UL I ULC Listed for indoor use with a temperature range of +0 C to +49 C (+32 F to+ 120 F) and maximum humidity of 93%. SIEMENS Industry, Inc. Building Technologies Division

4 Technical Data- (continued) SJUL Current Ratings ramps} Max1mum RMS Current with Hi dba Setting 15cd 30cd 75cd 95cd I DC I 16-33VDC I FWR I 16-33VRMS UL Gus rent Ratings (AMPS) Max1mum RMS Current w1th ~ dba Setting 15cd 30cd 75cd 95cd I DC I 16-33VDC VDC I FWR I 16-33VRMS VRMS UL Currem Ratings ramps) Note: These notification appliances are UL Listed as "Special Application". They are intended to be used only with Siemens notification appliance circuits. UL Listed Ratings Operating vo:tage (Special Apphc.acon) Stro!>e Model [Per UL 197~ Candela (VDCIVRMS) {cd) I'"S-HMC-U 16.1} /177 UL t1ba Sound Output Reverberant Volume [Per UL 464 ~ 10Ft] Jescription (LEVEL) 16.0VDC 24.0VDC 33.0VDC Low Continuous Hom Medium HiQh Low Code 3 Hom or = Medium \Aarch Time * High "Avaslable m sync mode only Notes: 1. Strobe will produce 1 flash per second over the Input Voltage range. 2. This strobe/horn model meets the required light distribution patterns defined in,!lul This model is UL Listed for indoor use with a temperature range of +32 F to+ 120 F (0 ( to +49 C) and maximum humidity of 93% + 2% RH. The effect of shipping and storage temperatures shall not adversely affect the performance of the appliance when it is stored in the original cartons and not subjected to misuse or abuse. SIEMENS Industry, Inc. Building Technologies Division

5 Technical Data- (continued) UL Cummt Ratings (AMPS} Maximum RMS Current.vith Hi dba Setti~ 135cd 185cd I DC I 16-33VDC I FWR I 16-33VRMS UL Current Ratings (AMPS} Max1mum RMS Current with~ dba Setting 135cd 185cd UL Cummt Ratings (AMPS} Max1mum RMS Current with!:qw dba Setting 135cd!85cd I DC I '16-33VDC I DC I 16-33VDC I FWR I 16-33VRMS I FWR I 16-33VRMS Details for Ordering- (Including Mounting Options & Agency Approvals) Agency Approvals \ Model Part Wall Ceiling Number Number Mount Mount AS-MC-R X AS MC W X - AS-HMC-R X AS-HMC W X - AS MC-CR X AS MC CW X AS HMC-CR X AS-HMC-CW X AS HMC CR WP X AS HMC CW WP X AS-HMC-R-WP X - AS-HMC-W-WP X - AS.75-R-WP X - AS-75-CR-WP X AH-R X X AH-W X X AH R-WP X X Description Mounting Options* UL ULC FM CSFM AS Horn: Multi-Candela, Red A,B,D,E,F,G,J,N,R,X X X X X AS Horn: Multi-Candela, White A,B,D,E,F,G,J,N,R,X X X X X AS Horn: Hi Multi-candela, Red A,B,D,E,F,G,J,N,R,X X X X X AS Horn: Hi Multi-Candela, White A,B,D,E,F,G,J,N,R,X X X X X AS Horn: Multi-Candela Ceiling, Red A,B,D,E,F,G,J,N,R,X X X X X AS Horn: Multi-Candela Ceilinq, White A,B,D,E,F,G,J,N,R,X X X X X AS Horn: Hi Multi-Candela Ceiling, Red A,B,D,E,F,G,J,N,R,X X X X X AS Horn: Hi Multi-Candela Ceiling, White A,B,D,E.F,G,J,N,R,X X X X X AS Horn: Hi Multi-Candela Ceiling Weatherproof, Red I X X X X AS Horn: Hi Multi-Candela Ceiling Weatherproof White I X X X X AS Horn: Hi Multi-Candela Wall Weatherproof, Red I X X X X AS Horn: Hi Multi-Candela Wall Weatherproof, White I X X X X AS. Horn: 75CD Weatherproof, Red I X X X X AS Horn: 75CD Ceiling Weatherproof, Red I X X X X AH Horn, Red A,B,D,E.F,G,J,N,R,X X X X X AH Horn, White A,B,D,E,F,G,J,N,R,X X X X X AH Horn: Weatherproof, Red K X X X X X =listed I approved *=Refer to data sheet#: 2585 for detailed mounting options SIEMENS Industry, Inc. Building Technologies Division

6 Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. SIEMENS Industry, Inc. Building Technologies Division Fire Safety 8 Fernwood Road Florham Park, NJ Tel: Fire Safety 2 Kenview Boulevard Brampton, Ontario (Sill L6T 5E4/ Canada Printed in l SA. Tel: (905) FAX: (905) March 2010 Supersedes sheet dated 12/09 (Rf!v. 1)

7 CONDITION #1 Stucco Door Surround, Painted Brick ~~-~:--~~~-...~~-~ ;3~07;;;~~3~t"" og N. George Ma~s~~-g.,. ~ ~ ~~~;.'..,-.~;. 1~ B.~ : I,~,.. -_...; ;~

8 : CONDITION #l. -. Stucco Door Surround, Painted Bdck 307;:3o9 N. George Mas.g.n; '.. 'ie. 1,~r. ~:~.- -., r..,~-...-,.. ~ :~_ ~..,~

9

10

11 t

12 Condition #5 Door Surround Style N. 4th I

13 '. Stucco Door Surround, Unpainted Brick ~:~~~:~~,.,..._ 320 ~ 4324 N. 4th, 31g:-321 N. Geo. Mason N. Pershing ~--~~~~

14

08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor

08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor s Data Sheet Fire Safety & Security Products 08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor AS-MC-CW AS-MC-R AH-W AH-R Product Overview

More information

s Notification Appliances

s Notification Appliances s Notification Appliances Data Sheet Fire Safety Products AS & AH Audible Horn Strobe / Audible Horn Appliances Application: Indoor / Outdoor AS-MC-CW AS-MC-R AH-R AH-W Product Overview Fast installation

More information

SELECT-A-HORN/STROBE SERIES

SELECT-A-HORN/STROBE SERIES SELECT-A-HORN/STROBE SERIES Features Description Mircom s Select-A-Strobe/Horn Series is designed to comply with the Americans with Disability Act (ADA) and meet UL standard 1971 requirements for emergency

More information

Wheelock RSS & RSSP Series

Wheelock RSS & RSSP Series Wheelock RSS & RSSP Series Single- and Multi-Candela Strobes and Strobe Plates DF-51780:A G-520 General Wheelock s patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current

More information

TrueAlert Multi-Candela Notification Appliances

TrueAlert Multi-Candela Notification Appliances TrueAlert Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved* Features 24 VDC high intensity notification appliance common features: Xenon strobe with intensity selectable as 135,

More information

TrueAlert Notification Appliances

TrueAlert Notification Appliances TrueAlert Notification Appliances UL Listed; FM, CSFM and MEA (NYC) Approved* Non-Addressable Audible/Visible Notification Appliances with SmartSync Operation of Strobes and Horns Features Wall mount audible/visible

More information

L-Series, Emergency Communication Devices

L-Series, Emergency Communication Devices Notification Appliances L-Series, Emergency Communication Devices Description The L-Series Emergency Communications devices and accessories combine application versatility with all of the same time-saving

More information

Speakers and Speaker Strobes

Speakers and Speaker Strobes Kingfisher Company, inc. Speakers and Speaker Strobes Features: Approvals include: UL Standard 1971, UL Standard 1480, New York City (MEA), California State Fire Marshall (CSFM), Factory Mutual (FM), and

More information

MEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL

MEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL March 30, 2000 Section: Audio/Visual Devices G-250 SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL System Sensor SpectrAlert Series strobes, horns, and combination horn/strobes are UL listed

More information

L-Series, Indoor Strobes and Horn Strobes

L-Series, Indoor Strobes and Horn Strobes Notification Appliances L-Series, Indoor Strobes and Horn Strobes Indoor Selectable-Output Strobes/Horn Strobes for Ceiling Applications General The L-Series audible visible notification products offer

More information

CSH24CH. Colored Light Strobe/Horn Series High Candela. Description. Features. Ceiling/Wall Mount Patent Pending. Ordering Information

CSH24CH. Colored Light Strobe/Horn Series High Candela. Description. Features. Ceiling/Wall Mount Patent Pending. Ordering Information OF FIRE CS24C Colored Light Strobe/orn Series igh Candela Ceiling/Wall Mount Patent Pending Description AMSECO's UL listed Colored Light Strobe CS24C series is designed to provide audible and visual signals

More information

Potter Wall Mount Select-A-Strobe

Potter Wall Mount Select-A-Strobe 104 Kenran Industrial Dr. Potter Wall Mount Select-A-Strobe SL-1224 SERIES SELECT-A-STROBE Call for additional listings 12 VDC with 15, 35 or 60 cd setting 24 VDC with 15, 35, 60, 5, 95 or 110 6 distinct

More information

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906 s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones

More information

1 Watt Supervised Self-Amplified Strobe Speakers Round Flush Grille with 75cd Strobe

1 Watt Supervised Self-Amplified Strobe Speakers Round Flush Grille with 75cd Strobe 273 Branchport Avenue Long Branch, N.J. 07740 (800) 631-2148 Thank you for using our products. www.wheelockinc.com INSTALLATION INSTRUCTIONS SUPERVISED SELF-AMPLIFIED STROBE SPEAKERS Use this product according

More information

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet Table 1: Models Description Low frequency (520 Hz) horn, white housing, no FIRE marking, standard output clear strobe light Low frequency (520

More information

TrueAlert Multi-Candela Notification Appliances

TrueAlert Multi-Candela Notification Appliances UL, ULC Approved* TrueAlert Multi-Candela Notification Appliances Non-Addressable Visible Only Amber Lens Strobes for Emergency Communications Features Visible only (V/O) 24 VDC wall mount notification

More information

L-Series, Indoor Strobes and Horn Strobes

L-Series, Indoor Strobes and Horn Strobes Notification Appliances L-Series, Indoor Strobes and Horn Strobes Indoor Selectable-Output Horns, Strobes and Horn Strobes for Wall Applications General The L-Series audible visible notification products

More information

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E SpectrAlert Advance Description System Sensor SpectrAlert Advance offers a variety of devices designed for mass notification, including plain devices for non-fire applications, amber lens strobes and speaker

More information

TrueAlert Addressable Notification Appliances

TrueAlert Addressable Notification Appliances UL, ULC, CSFM Listed, FM Approved TrueAlert Addressable Notification Appliances Audible/Visible Notification Appliances, Wall Mount Multi-Candela Horn/Strobe, Model Series 49AV Features Individually addressed

More information

TrueAlert Addressable Notification Appliances

TrueAlert Addressable Notification Appliances UL, ULC Listed* TrueAlert Addressable Notification Appliances Audible/Visible Notification Appliances; Multi-Tone Horn/Strobe with 520 Hz Output Features Individually addressed and controlled multi-tone

More information

11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies

11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies 11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies Visible Signals Agenda 1. Physics 2. Installation Considerations

More information

Dimensions of the Optional Mounting Box (BB-400R/W)

Dimensions of the Optional Mounting Box (BB-400R/W) Wall and Ceiling Notification Appliances This manual applies to the following models Horn only FH-400-WW and FH-400-RR - wall and ceiling mounted horn Strobe only FS-400-WW and FS-400-RR - wall mounted

More information

Genesis LED G1 Series

Genesis LED G1 Series EDWARDS Catalog u Strobes, Horns, Bells, Chimes LIFE SAFETY INCIDENT MANAGEMENT Genesis LED G1 Series Compact Notification Devices S218, S5389 7125-1657:0506 7135-1657:0502 Overview Genesis LED G1 Series

More information

Field Configurable Horns and Strobes

Field Configurable Horns and Strobes EDWARDS Catalog u Strobes, Horns, Bells, Chimes LIFE SAFETY & INCIDENT MANAGEMENT Field Configurable Horns and Strobes Genesis Series ECS/MNS appliances available with clear or amber lenses. S218, S5389,

More information

Installation Instructions Model ABHW-4S

Installation Instructions Model ABHW-4S Installation Instructions Model ABHW-4S Intelligent Audible Base for Sleeping Area with 520Hz Low Frequency Sounder Introduction Application note The Model ABHW-4S audible base from Siemens Industry, Inc.

More information

Field Configurable Horns and Strobes

Field Configurable Horns and Strobes Vigilant Catalog Strobes, Horns, Bells, Chimes Field Configurable Horns and Strobes Genesis Series MNEC appliances available with clear or amber lenses. Pending Overview The Genesis line of fire alarm

More information

FIRE ALARM Submittal DR. PECK FHM DAYTONA 4TH FL 125 MEMORIAL MEDICAL PARKWAY DAYTONA BEACH, FL 32117

FIRE ALARM Submittal DR. PECK FHM DAYTONA 4TH FL 125 MEMORIAL MEDICAL PARKWAY DAYTONA BEACH, FL 32117 SIEMEN FIRE ALARM Submittal Project Name: DR. PECK FHM DAYTONA 4TH FL 125 MEMORIAL MEDICAL PARKWAY DAYTONA BEACH, FL 32117 Project : DATE SUBMITTED: 11/10/14 WILE COPY SIEMENS Industry Inc. Building Technologies

More information

Life safety notification

Life safety notification LED Wheelock Exceder LED3 Life safety notification Meeting the latest codes with increased energy-efficiency in a compact design Wheelock Exceder LED3 Compliant, compatible, compact, and energy efficient

More information

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions TrueAlert NonAddressable, MultiCandela Notification Appliances Installation Instructions PRODUCT IDENTIFICATION REFERENCE (See Page 4 for Detailed Product Specifications) Type Mount Model Color Operation

More information

Air Duct Housings. Description

Air Duct Housings. Description Air Duct Housings Series IL, and Series 3 Ionization or Photoelectric Detectors Optional Relays for Supplementary Equipment Operation Optional Control Module for Self-contained Operation (Series 3 Detectors

More information

*15cd models are Listed at 15cd and meet 75cd on axis

*15cd models are Listed at 15cd and meet 75cd on axis 273 Branchport Avenue Long Branch, NJ 07740 Thank you for using our products. (800) 631-2148 INSTALLATION INSTRUCTIONS www.wheelockinc.com MULTITONE STROBE APPLIANCES Use this product according to this

More information

Fire Safety. Installation Instructions. Model ADBX-11. Audible Base INTRODUCTION. Model ADBX-11

Fire Safety. Installation Instructions. Model ADBX-11. Audible Base INTRODUCTION. Model ADBX-11 Fire Safety Installation Instructions Model ADBX11 Audible Base INTRODUCTION Model ADBX11 The SIEMENS Model ADBX11 Audible Base consists of a standard Series 11 base combined with an audible device. All

More information

s Notification Appliances Mounting Options

s Notification Appliances Mounting Options s Notification Appliances Mounting Options Mounting Diagrams Mounting Matrixes Mounting Notes Data Sheet Fire Safety Products ARCHITECT AND ENGINEER SPECIFICATIONS 08 Series Notification Appliances 2585

More information

MOUNTING DETAILS. Mounting Matrix / Details ENGINEER AND ARCHITECT SPECIFICATIONS CATALOG SHEET. 2-1/8 Deep

MOUNTING DETAILS. Mounting Matrix / Details ENGINEER AND ARCHITECT SPECIFICATIONS CATALOG SHEET. 2-1/8 Deep MOUNTING DETAILS Mounting Matrix / Details (a) universal mounting plate ENGINEER AND ARCHITECT SPECIFICATIONS (e) 4 square, deep, flush (bo) 2-1/8 Deep AS Mounting (item included with AS series devices)

More information

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS SXL Conventional Zone Fire Alarm Control Panel ENGINEER AND ARCHITECT SPECIFICATIONS 4 Zones Expandable to 8 Zones Microprocessor Based Control Factory Programmed Field Configurable 2 Style Y Notification

More information

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual Fire Safety Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual Siemens Building Technologies, Inc. Siemens Building Technologies, Ltd. 8 Fernwood Road 2 Kenview

More information

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS CSM-4 Controllable Signal/Releasing Module ENGINEER AND ARCHITECT SPECIFICATIONS Supervised Alarm Notification Appliance Circuits Operates Audible or Visual Devices Class A (Style Z) or Class B (StyleY)

More information

Sinorix Engineered Fire Suppression Systems For use with Novec TM 1230 Fire Protection Fluid and HFC-227ea

Sinorix Engineered Fire Suppression Systems For use with Novec TM 1230 Fire Protection Fluid and HFC-227ea s Data Sheet Fire Safety Products Sinorix Engineered Fire Suppression Systems For use with Novec TM 1230 Fire Protection Fluid and HFC-227ea ARCHITECT AND ENGINEER SPECIFICATIONS System Overview Sinorix

More information

Desigo Fire Safety Marine Fire and Detection Equipment Models FH-2071-UM, BP-62 and USCG-HPLATE

Desigo Fire Safety Marine Fire and Detection Equipment Models FH-2071-UM, BP-62 and USCG-HPLATE s Desigo Fire Safety Marine Fire and Detection Equipment s FH-2071-UM, BP-62 and USCG-HPLATE ARCHITECT AND ENGINEER SPECIFICATIONS Marine equipment is used with Desigo 252-point and 504-point addressable

More information

Selectable Output Chimes and Chime/Strobes

Selectable Output Chimes and Chime/Strobes Selectable Output Chimes and Chime/Strobes PRELIMINARY DN-60940:A Audio/Visual Devices General System Sensor L-Series selectable-output chimes and chime/ strobes are rich with features guaranteed to cut

More information

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

Use this product according to this instruction manual. Please keep this instruction manual for future reference. 273 Branchport Avenue Thank you for using our products. Long Branch, NJ 07740 (800) 631-2148 INSTALLATION INSTRUCTIONS www.cooperwheelock.com E50 MULTI-CANDELA SPEAKER STROBES GENERAL: Use this product

More information

LifeAlarm Fire Alarm Controls

LifeAlarm Fire Alarm Controls UL, ULC Approved* LifeAlarm Fire Alarm Controls 4009 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs Features Provides additional notification appliance circuit (NAC) capacity

More information

TrueAlert ES Addressable Notification Appliances

TrueAlert ES Addressable Notification Appliances UL, ULC, CSFM Listed; FM Approved* TrueAlert ES Addressable Notification Appliances Visible Notification Appliances, Wall Mount Multi-Candela Strobes, Model Series 49VO Features Individually addressed

More information

Agent Release Control Panel

Agent Release Control Panel Agent Release Control Panel System Capacity Annunciators: 8 Electrical Specifications RP-2002 (FLPS-7 Power Supply): 120 VAC, 60 Hz, 3.66 amps RP-2002E (FLPS-7 Power Supply): 240 VAC, 50 Hz, 2.085 amps

More information

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card XP6-C Six Circuit Supervised Control Module and SYNC-1 Accessory Card General NOTIFIER s XP6-C six-circuit supervised control module provides intelligent alarm systems with supervised monitoring of wiring

More information

9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE

9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE Cerberus PRO Marine Fire and Detection Equipment s FH-2071-UM, BP-62 and USCG-HPLATE Cerberus PRO Fire Safety Products ARCHITECT AND ENGINEER SPECIFICATIONS Marine equipment is used with Cerberus PRO 252-point

More information

TrueAlert Addressable Notification Appliances

TrueAlert Addressable Notification Appliances UL, ULC Approved* TrueAlert Addressable Notification Appliances Audible Notification Appliances; Multi-Tone Horns with 520 Hz Output Features Individually addressed and controlled TrueAlert ES multi-tone

More information

Desigo TM Fire Safety System A comprehensive fire-protection system

Desigo TM Fire Safety System A comprehensive fire-protection system s Desigo TM Fire Safety System A comprehensive fire-protection system Standard 50-point, 252-point and 504-point-capacity systems Remote viewing for the 252- point and 504-point systems One (1) or (2)

More information

Table 1: dba Ratings for AMT Multitone Signal Typical Anechoic dba at 10 Feet per CAN/ULC S525-07

Table 1: dba Ratings for AMT Multitone Signal Typical Anechoic dba at 10 Feet per CAN/ULC S525-07 273 Branchport Avenue Long Branch, NJ 07740 (800) 631-2148 (USA) Thank you for using our products. (800) 397-5777 (CANADA) www.coopernotification.com GENERAL: INSTALLATION INSTRUCTIONS AMT MULTITONE APPLIANCES

More information

advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize

advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize advanced ideas advancedsolutions At System Sensor, Research and Development is more than a department. It s a way of life. Every day we work to design new products that utilize the most innovative technologies

More information

Fire Safety. Installation Instructions. Model RCC-2/R and RSE-1 Remote Control Centers OPERATION INTRODUCTION INSTALLATION

Fire Safety. Installation Instructions. Model RCC-2/R and RSE-1 Remote Control Centers OPERATION INTRODUCTION INSTALLATION Fire Safety Installation Instructions Model RCC-/R and RSE- Remote Control Centers INTRODUCTI The SIEMENS Model RCC-/R Remote Command Center (See Figure ) provides the option to remotely annunciate and

More information

ELECTRONIC SOUNDER STROBE Model : AVD-C407

ELECTRONIC SOUNDER STROBE Model : AVD-C407 ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an

More information

good things in small packages

good things in small packages FireShield Control Panels good things in small packages life safety for small buildings and shops A perfect arrangement FireShield offers the very best conventional fire alarm technology available, with

More information

AL800ULADA. NAC Power Extender. Installation Guide

AL800ULADA. NAC Power Extender. Installation Guide AL800ULADA NAC Power Extender Installation Guide Rev. 122000 AL800ULADA - NAC Power Extender Overview: The Altronix AL800ULADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery

More information

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system s Data Sheet Fire Safety & Security Products Cerberus TM PRO Fire Safety System A comprehensive fire-protection system Standard 50-point, 252-point and 504-point-capacity systems Remote viewing for the

More information

Addressable Fire Alarm Control Panel

Addressable Fire Alarm Control Panel PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT

More information

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev Installation Guide for AL800UL-ADA NAC Power Extender Rev. 090500 Overview: The Altronix AL800UL-ADA is an extremely cost effective 8 amps voltage regulated remote power supply /battery charger. The AL800UL-ADA

More information

Hazardous Location Supervised Warning Light

Hazardous Location Supervised Warning Light FEDERAL SIGNAL CORPORATION Hazardous Location Supervised Warning Light Model 154XST RUGGED DESIGN FOR USE IN HAZARDOUS LOCATIONS Available in 24VDC Four wires and supervisory diode Six dome colors 10,000-hour

More information

Installation Instructions Model HZM

Installation Instructions Model HZM Installation Instructions Model Remote Conventional Zone Module INTRODUCTION The Model from is an intelligent device that connects a single zone of conventional devices to a DLC (FireFinder-XLS System)

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 031703 Overview: The Altronix AL802ULADA is an extremely cost effective 8 amp voltage regulated

More information

SAFEPATH Mass Notification System (SPMNS)

SAFEPATH Mass Notification System (SPMNS) Supersedes February 2016 SAFEPATH Mass Notification System (SPMNS) SP40S SPB-320 SPB-80/4 SPB-160 PS-8-LP SPMNS-MIC SP4Z-A/B Contents Page SPMNS.... 2-4 SPMNS-MIC...3 Expansion Options SAFEPATH 2-zone

More information

Conventional Releasing Control Panel

Conventional Releasing Control Panel s Data Sheet Fire Safety Products Conventional Releasing Control Panel Pre-Action Deluge Agent-Releasing Fire System Model TXR-320 Remote configurable Up to two (2) hazard areas Operable with the following:

More information

Autonomous control unit

Autonomous control unit Supersedes October 2016 Autonomous control unit Description Eaton s Autonomous Control Unit (), part of the ALERiTY integrated MNS platform, is a supervised in-building emergency communications system

More information

1. POWERPATH Operation

1. POWERPATH Operation 273 Branchport Avenue Long Branch, NJ 07740 (800) 631-2148 www.wheelockinc.com Thank you for using our products. INSTALLATION INSTRUCTIONS MODEL PS-12/24-6 POWERPATH Use this product according to this

More information

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS ECC-50/100(E) Emergency Command Center DF-60734:A4 General Firelite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,

More information

Addressable Detectors & Bases

Addressable Detectors & Bases Edwards Signaling Catalog u Intelligent Initiating Addressable Detectors & Bases Detectors: E-PD, E-PHD, E-HD Bases: B4U, RB4U, IB4U, SB4U Overview Edwards intelligent addressable detectors are meticulously

More information

L-Series Audible Visible Notification PRODUCTS. Accessories Chimes Chime Strobes ECS and MNS Horns Horn Strobes Speakers Speakers Strobes Strobes

L-Series Audible Visible Notification PRODUCTS. Accessories Chimes Chime Strobes ECS and MNS Horns Horn Strobes Speakers Speakers Strobes Strobes L-Series Audible Visible Notification PRODUCTS Accessories Chimes Chime Strobes ECS and MNS Horns Horn Strobes Speakers Speakers Strobes Strobes 2 Simple to install, yet powerful enough to meet any requirement.

More information

GEC Low-frequency Horn Strobes

GEC Low-frequency Horn Strobes Fire Alarm Systems GEC Low-freqency Horn Strobes GEC Low-freqency Horn Strobes Silence the horn while strobes flash Evacation tone Use the SperSlide featre for easy testing Wide voltage range; 16 to 33

More information

AL600ULADA. NAC Power Extender. Installation Guide

AL600ULADA. NAC Power Extender. Installation Guide AL600ULADA NAC Power Extender Installation Guide Rev. 122000 AL600ULADA - NAC Power Extender Overview: The Altronix AL600ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery

More information

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS PXL Conventional Zone Fire Alarm Control Panel ENGINEER AND ARCHITECT SPECIFICATIONS 12 Zone System Expandable to 32 10 Amp Base Power Supply Multiple Power Supplies Available - Local or Remote 4 Notification

More information

ECC-50/100C. Emergency Command Center

ECC-50/100C. Emergency Command Center ECC-50/100C Emergency Command Center Canadian DF-60815:B Emergency Communications General Fire-lite s ECC-50/100C is a multipurpose emergency voice evacuation panel for fire applications, mass notification

More information

31566 Railroad Canyon Road STE 2 Canyon Lake, CA Office Fax

31566 Railroad Canyon Road STE 2 Canyon Lake, CA Office Fax Date 9-10-2016 Project: Field Elementary School Pasadena, CA FIRE ALARM SUBMITAL Devices Used DESCRIPTION MODEL MANUFACTURE CSFM SMOKE DETECTOR FSP-851 NOTIFIER 7272-0559;0129 HEAT DETECTOR FST-851H NOTIFIER

More information

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM Waterflow Alarm Submittal Booklet For MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM 380 South 5th St Monroe, OR 2G CONSTRUCTION PO Box 11735 Eugene, OR Convergint Technologies LLC 16575 SW 72nd Avenue

More information

TrueAlert Addressable Notification Appliances

TrueAlert Addressable Notification Appliances Fire Control ** IS NORMAL ** :0:pm Mon 9-Feb-9 SY S TE M AC SUPERVISORY TROUB LE SILENCED SUPV TROUBLE SILENCE RESET CONTROL DISC ON NEC T POW ER + V ZONE P WR + 0V ZONE P WR - +IDNE T IDC + - IDNE T IDC

More information

The Advance You ve Been Looking For

The Advance You ve Been Looking For The Advance You ve Been Looking For The Power Behind The Products System Sensor was founded in 1984 and today is the largest manufacturer of fire detection and notification appliances in the world. More

More information

SAFEPATH DoD facility communications system & expansion options

SAFEPATH DoD facility communications system & expansion options Supersedes September 2011 SAFEPATH DoD facility communications system & expansion options SP40S-D SPB-320 SPB-80/4 SPB-160 SP4-TZC SPRM SP4Z-A/B SP-SVC Contents Description Page SP40S-D Communications

More information

Signature Series Auto-Sync Output Module (CC1S)

Signature Series Auto-Sync Output Module (CC1S) Signature Series Auto-Sync Output Module (CC1S) Product description Mounting The Signature Series can be mounted in a North American 2-1/2 in (64 mm) deep 2-gang box or a standard 4 in square box 1-1/2

More information

Cerberus PRO A comprehensive fire-protection system

Cerberus PRO A comprehensive fire-protection system Cerberus PRO A comprehensive fire-protection system Cerberus TM ARCHITECT AND ENGINEER SPECIFICATIONS Standard 252-point and 504-point fire systems Remote viewing for the 252- point and 504-point systems

More information

ECC-50/100(E) Emergency Command Center

ECC-50/100(E) Emergency Command Center ECC-50/100(E) Emergency Command Center DF-60734:A9 C-200 General Fire Lite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,

More information

Protect. Alert. Inform.

Protect. Alert. Inform. Life safety & mass notification solutions Product Catalog Protect. Alert. Inform. Leading the industry in advanced technological solutions The performance you rely on Cooper Notification now from Eaton

More information

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION Fire Safety Installation Instructions Model SMB- Main Control Board OPERATION The SIEMENS Model SMB- board in each MXL-IQ System controls operations and monitors input device identity, network communication,

More information

Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations

Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations CEILING 116EX-C 3/ CONDUIT ENTRIES PENDANT 116EX-P 3/ CONDUIT ENTRY 116EX-C (WALL MOUNTED)

More information

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING GENERAL The VEC 25/50 is a state-of-the-art, compact, stand-alone or slave Emergency Voice Evacuation Control. The VEC 25/50 is offered in a self-contained, cost-effective design and includes a 25 Watt,

More information

Desigo TM Fire Safety System A comprehensive fire-protection system

Desigo TM Fire Safety System A comprehensive fire-protection system s Desigo TM Fire Safety System A comprehensive fire-protection system Standard 252-point and 504-point capacity systems Remote viewing for the 252- point and 504-point systems One (1) or (2) two-heightunit

More information

Fire Alarm Devices. Drexel Thrash Laborers Training Center. Supplier: Tri S Controls

Fire Alarm Devices. Drexel Thrash Laborers Training Center. Supplier: Tri S Controls Oh, Lic #26962 Drexel Thrash Laborers Training Center Fire Alarm Devices Supplier: Tri S Controls SHOP DRAWINGS Lake Erie Electric, Inc. FOR DWG. & SPEC. CONFORMITY ONLY D.M.Y 08/17/2016 By ebelba at 11:16

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS 100+ YEARS Federal Signal is recognized as one of the industry s leading suppliers of safety

More information

WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations.

WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations. Cheshire, CT 064 3-699-30 (Ph) 3-699-3365 (Cust. Serv. Fax) 3-699-78 (Tech. Serv. Fax) Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations STANCHION

More information

TrueAlarm ES Analog Sensing

TrueAlarm ES Analog Sensing TrueAlarm ES Analog Sensing UL, ULC, CSFM Listed; FM Approved* Features TrueAlarm addressable sensor base with 520 Hz sounder TrueAlarm sensor bases with 520 Hz tone require a TrueAlarm photoelectric,

More information

SAFEPATH SAFEPATH. Emergency communications system

SAFEPATH SAFEPATH. Emergency communications system SAFEPATH SAFEPATH Emergency communications system ALERiTY Integrated mass notification solutions by Eaton; designed to protect, alert and inform your most critical resources your people ALERiTY /a ler

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 042010 Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864).

More information

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262) PATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262) NAC ETENDER SUPPLIES Installation Instructions 273 Branchport Avenue, Long Branch, NJ 07740-6899 Ph: (800) 631-2148 Fax: (732) 222-8707 Web

More information

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM OSU PROJECT NO. 30-04-15 PAGE 1 PART 1 GENERAL 1.1 WORK INCLUDED A. Provide all labor, materials, and equipment required to provide a complete and operating system of manual and automatic detection devices,

More information

Intelligent Detection Devices

Intelligent Detection Devices Intelligent Detection Devices Multi-Criteria Fire Detector [with ASAtechnology TM ] Advanced multi-criteria fire detector that has dual-optical and thermal sensors Differentiates between deceptive phenomena

More information

Installation Instructions Model SSD-C-REM

Installation Instructions Model SSD-C-REM Installation Instructions Model SSD-C-REM Remote System Status Display with Control ON ALARM SUPERVISORY SECURITY TROUBLE AUDIBLES SILENCED INTRODUCTION The SIEMENS Model SSD-C-REM is an optional FireFinder

More information

June 10, 2002 DF C S2424

June 10, 2002 DF C S2424 GENERAL www.firelite.com The Fire Lite FIRE COMMAND 25/50X is a state-of-theart Emergency Voice Evacuation Control Panel (VECP), with significant technological enhancements that set it apart from other

More information

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM DIVISION 26 ELECTRICAL SECTION 26 81 11 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install all equipment and accessories for a complete local, analog addressable, manually and automatically actuated,

More information

Analog fire panels FPA-1000 Family

Analog fire panels FPA-1000 Family Analog fire panels FPA-1000 Family en NAC Compatibility List Analog fire panels NAC compatibility en 3 1 NAC compatibility 1.1 General notes Bosch Security Systems found the following notification appliance

More information

AL602ULADA AL802ULADA AL1002ULADA

AL602ULADA AL802ULADA AL1002ULADA AL602ULADA AL802ULADA AL1002ULADA NAC Power Extenders Application Guide (See Installation Guide for additional information) Rev. 031703 1. General Information (Use this in conjunction with respective Installation

More information

FireFinder XLSV Digital Emergency Voice Alarm / Communication System

FireFinder XLSV Digital Emergency Voice Alarm / Communication System s Data Sheet Fire Safety Products FireFinder XLSV Digital Emergency Voice Alarm / Communication System ARCHITECT AND ENGINEER SPECIFICATIONS Eight (8) digital audio channels Compatible with Model PMI-3

More information