Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor
|
|
- Shanon James
- 5 years ago
- Views:
Transcription
1 Report No EC FM Approvals Ltd 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT Product: Model and/or Type Reference: Flame Detector IPES-IR3 Description of the Product: As described on Page B. Date of Assessment and Test: 25 July 2011 Name of Report Holder: Address of Report Holder: Name of Manufacturer: Address of Manufacturer: ATEX Certification Code: Electronstandart-pribor No. 35/2 Slavy Avenue Saint Petersburg Russian Federation As above 120 th Gatchinskoy divizii str, Promzona-2, Gatchina, Leningradskaya oblast Russian Federation II 2 G Ex d IIC T4 Gb Ta = -40 C to +85 C; IP66 The above product has been assessed against, and found to be in conformity with, the Essential Health and Safety Requirements (EHSR s) of the ATEX Directive as identified herein. This report has been established by a body notified to the Member States and Commission of the European Communities according to the provisions of Article 9 of the ATEX Directive 94/9/EC of 23 March This report comprises: this front sheet + 8 pages and attachments. Only integral reproduction of this Report, or reproductions of this page accompanied by any page(s) on which are stated the assigned rated characteristics of the apparatus tested, are permitted without written permission from FM Approvals Ltd, 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS FM Approvals...Engineer Marlon Mitchell Verified &...Authorised by Andrew Lozinski...25 July Date F ATEX 090 (Jun/10)
2 Record of Proving Tests & Assessments Report No EC Description of the Product: The IPES-IR3 Flame Detector is a nominal 24 Vdc (18 to 32 Vdc range) device intended for connection to a compatible controller that provides separate power and alarm initiating circuits. Output options include dry Form C relay contacts (rated 10 ma to 5 A at 32 Vdc), a 4-20 ma analog output and RS-485 digital signal protocol output. The IPES-IR3 Flame Detector enclosure is a cylindrical shaped housing constructed of aluminum alloy. Both ends of the housing are closed by covers. The base cover is solid and contains the external grounding lug, wiring entry and bracket mounting post. The window cover contains one sapphire lens cemented in place and externally protected by permanent guards. The window cover also contains the mounting holes for the electronics. The base cover is provided with one ¾ inch - 14 NPT conduit entry. O-rings are provided on the covers for environmental protection. The maximum free internal volume of the apparatus is approximately 452 cm 3. All applicable testing of the IPES-IR3 Flame Detector was conducted under FM Approvals Project IDs , , and Product Listing: IPES-IR3 Flame Detector. FM11ATEX0045X II 2 G Ex d IIC T4 Gb Ta = -40 C to +85 C; IP66 Special Conditions of Use: 1. Consult the manufacturer if dimensional information on the flameproof joints is necessary. 2. The manufacturer specifies the cover fasteners to be M5 x 16 hexagon socket head cap screws of A2-70 stainless steel quality or better. THIS REPORT MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE FM Approvals. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS T: +44 (0) F: +44 (0) atex@fmapprovals.com F ATEX 090 (Jun/10) Page B
3 Record of Proving Tests & Assessments Report No EC Test and Assessment Procedure and Conditions: This Test and Assessment Report is the result of testing of a sample of the product submitted, in accordance with the provisions of the relevant specific standard(s), and assessment of supporting documentation. It does not imply an assessment of the whole production. The manufacturer of the equipment referred to in this report has the responsibility to ensure that the apparatus conforms to the specification laid down in this report and has satisfied the routine verifications and tests referred to therein. This Test and Assessment Report has been issued in accordance with FM Approvals ATEX Certification Scheme and may be supported by subsequent supplementary reports. Compliance with the Essential Health and Safety Requirements (EHSR s): The product, as identified herein, has been assessed against and found to be in conformity with, the Essential Health and Safety Requirements (EHSR s) of the ATEX Directive. The record of the EHSR assessment has been retained by FM Approvals Ltd. Conditions Relating to Compliance with other Applicable EU Directives: Whilst CE Marking is referred to in the body of this certificate, FM Approvals accepts no responsibility for the compliance of the equipment against all applicable Directives in all applications. Observations and Comments Identified during Test & Assessment: None. THIS REPORT MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE FM Approvals. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS T: +44 (0) F: +44 (0) atex@fmapprovals.com F ATEX 090 (Jun/10) Page C
4 Record of Proving Tests & Assessments Report No EC Test & Assessment Reports: The following documents are appended to this report: Report Number Issued by Date (dd/mm/yy) No. of Pages Title / Description FM Approvals 25/07/11 5 IPES-IR3 FLAME DETECTOR Submitted Drawings, Documents and Datasheets: The manufacturer has submitted drawings, documents and datasheets, (including where applicable, information on software control) in relation to the product(s) described within this report. These submitted drawings, documents and datasheets, (including where applicable, information on software control,) have been identified within the attached FM Approvals report and copies retained by FM Approvals. THIS REPORT MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE FM Approvals. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS T: +44 (0) F: +44 (0) atex@fmapprovals.com F ATEX 090 (Jun/10) Page D
5 Not to be distributed outside of FM Approvals and its affiliates except by Customer TEST AND ASSESSMENT REPORT IPES-IR3 FLAME DETECTOR Test and Assessment Report Prepared by: FM Approvals LLC 1151 Boston-Providence Turnpike Norwood, MA USA Test and Assessment Report Prepared for: FM Approvals Ltd 1 Windsor Dials Windsor, Berkshire SL4 1RS UK On behalf of: Electronstandart-pribor No. 35/2 Slavy Avenue Saint Petersburg Russian Federation Report By: Reviewed By: Marlon Mitchell, Advanced Engineer Andrew Lozinski, Technical Team Manager Class: FMA Date of Approval: 25 July 2011 Page 1 of 5
6 FM APPROVALS I INTRODUCTION 1.1 Electronstandart-pribor (manufacturer) requested FM Approvals perform examination and testing of their IPES-IR3 Flame Detector listed in Section 1.3 to be in compliance with the applicable requirements of the standards listed in Section 1.2 for the issue of an EC-Type Examination Certificate as Group II Category 2 for use in Gases (II 2 G) Ex d IIC with Ingress Protection IP Standards for ATEX Certification Title Author-Number Issue Date Explosive atmospheres Part 0: Equipment General Requirements EN Explosive atmospheres Part 1: Equipment protection by flameproof EN enclosures d Degrees of protection provided by enclosures (IP code) EN A European (ATEX) Listing - The equipment described in this report will appear in the FM Approval Guide, an online resource of FM Approvals, as follows: IPES-IR3 Flame Detector. FM11ATEX0045X II 2 G Ex d IIC T4 Gb Ta = -40 C to +85 C; IP66 Special Conditions of Use: 1. Consult the manufacturer if dimensional information on the flameproof joints is necessary. 2. The manufacturer specifies the cover fasteners to be M5 x 16 socket head cap screws of A2-70 stainless steel quality or better. II DESCRIPTION 2.1 General - The IPES-IR3 Flame Detector is a nominal 24 Vdc (18 to 32 Vdc range) device intended for connection to a compatible controller that provides separate power and alarm initiating circuits. Output options include dry Form C relay contacts (rated 10 ma to 5 A at 32 Vdc), a 4-20 ma analog output and RS-485 digital signal protocol output. 2.2 Construction - The IPES-IR3 Flame Detector enclosure is a cylindrical shaped housing constructed of aluminum alloy. Both ends of the housing are closed by covers. The base cover is solid and contains the external grounding lug, wiring entry and bracket mounting post. The window cover contains one sapphire lens cemented in place and externally protected by permanent guards. The window cover also contains the mounting holes for the electronics. The base cover is provided with one ¾ inch - 14 NPT conduit entry. O- rings are provided on the covers for environmental protection. The maximum free internal volume of the apparatus is approximately 452 cm 3. Page 2 of 5
7 FM APPROVALS III EXAMINATION AND TESTS 3.1 All applicable testing of the IPES-IR3 Flame Detector was conducted under FM Approvals Project IDs , , and All documents and correspondence applicable to this program is on file at FM Approvals. 3.2 Flameproof Ex d Examination and Testing Against EN and EN The IPES-IR3 Flame Detector was satisfactorily assessed against IEC standards :2007 Ed. 5 and IEC :2007 Ed. 6 as flameproof Ex d IIC T4 Gb Ta = -40 C to +85 C as described in IECEx Test Report US/FMG/ExTR /00 (FM Approvals Project ID ). As the EN and EN standards are harmonized with the IEC and IEC standards, the assessment in the referenced IECEx test report is considered to be satisfactory for flameproof for II 2 G Ex d IIC T4 Gb Ta = -40 C to +85 C. 3.3 The following additional marking has been added for compliance with the ATEX Directive 94/9/EC The specific marking for explosion protection,, along with the associated 0470 for the Notified Body responsible for the surveillance of the quality system (per Annex VII of 94/9/EC) The address of the manufacturer The category marking II 2 G supplements the Equipment Protection Level marking Gb. IV MARKINGS The manufacturer's steel nameplate is permanently secured to the exterior of the enclosure. The markings, as depicted on drawing GSKF FM Rev , are shown below. V REMARKS Installation shall be in accordance with the manufacturer's instructions and EN , as applicable. VI SPECIAL CONDITIONS OF USE / SCHEDULE OF LIMITATIONS 1. Consult the manufacturer if dimensional information on the flameproof joints is necessary. 2. The manufacturer specifies the cover fasteners to be M5 x 16 socket head cap screws of A2-70 stainless steel quality or better. Page 3 of 5
8 FM APPROVALS VII MANUFACTURER'S RESPONSIBILITIES 7.1 The manufacturer shall advise FM Approvals of all proposed changes to the documents listed in Section IX. No changes of any nature shall be made unless notice of the proposed changes has been submitted and written authorization obtained from FM Approvals. The Approved Product-Revision Report, FM Approvals Form 797, shall be forwarded to FM Approvals as notice of proposed changes. 7.2 On 100% of production, the manufacturer shall inspect the protective grounding system. VIII FACILITIES AND PROCEDURES AUDIT The manufacturer's design control and manufacturing facilities located in Gatchina, Leningradskaya oblast, Russian Federation is subject to follow-up audit inspections. The facilities and quality control procedures in place have been found to be satisfactory to manufacture product identical to that examined and tested as described in this report. IX DOCUMENTATION FILE The following drawings depict the design of the equipment identified in Section 1.3 and are on file at FM Approvals, blueprint file Drawing No. Drawing Title Revision GSKF Cover, Parts List GSKF AD Cover, Assembly 1 GSKF Base, Parts List GSKF AD Base, Assembly GSKF Controller Board, Parts List GSKF E3 Controller Board, Electrical Schematic GSKF AD Controller Board, Assembly GSKF Signal Board, Parts List GSKF AD Signal Board, Assembly GSKF E3 Signal Board, Electrical Schematic GSKF Flame Detector IPES-IR3 Parts List GSKF OM Operating Manual IPES-IR3 MAY GSKF AD Flame Detector IPES-IR3 Assembly 2 GSKF E6 Flame Detector IPES-IR3 Electrical Schematic GSKF Interconnecting Board Parts List GSKF AD Interconnecting Board Assembly GSKF E3 Interconnecting Board Electrical Schematic GSKF Switching Board IPES-IR3 Parts List GSKF AD Switching Board IPES-IR3 Assembly GSKF E3 Switching Board IPES-IR3 Electrical Schematic GSKF E4 Switching Board IPES-IR3 Wiring Layout Page 4 of 5
9 FM APPROVALS GSKF AD Supply Board Assembly GSKF E3 Supply Board Electrical Schematic GSKF SP Supply Board, Parts List GSKF Installation Board Parts List GSKF AD Installation Board Assembly GSKF E3 Installation Board Electrical Schematic GSKF Protecting Window GSKF Cover 1 GSKF Base 1 GSKF Case 2 GSKF AD Case Assembly GSKF SP Case Parts List GSKF FM Nameplate X CONCLUSION On the basis of the described test and assessment, it is concluded that the equipment identified in Section 1.3 of this report meets the requirements for the issue of an EC-Type Examination Certificate by FM Approvals Ltd. as requested in the application. Effective date is the issue date of the EC-Type Examination Certificate. EXAMINATION BY: M. Mitchell ORIGINAL DATA: Project Data Records *, , and (*PDR contains EHSR and Directive Compliance Statement) ATTACHMENTS: None Page 5 of 5
IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Certificate history: Status:
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBG15E and BExBG10E Flameproof / Increased Safety Xenon Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG15E and BExBG10E beacons are flameproof
More informationCertificate of Compliance
FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The
More informationFINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,
FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. ON FLOW MONITOR, GPE3000 SERIES, REPORT NO. TRA-015825-33-00A ExTR Reference No. TRA-015825-33-00A
More informationCertificate of Compliance
FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296
More informationSUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE)
SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE) SCS/SF/053-8 Issue 1 Sira Certification Service INTRODUCTION One of the conditions placed on all holders of Sira
More informationCertificate of Compliance
Certificate of Compliance This certificate is issued for the following: KS103SSF, KS103MSF, AND KS110CTF PANELS AS CLASS 1 INTERIOR WALL AND CEILING PANELS FOR INSTALLATION WITH NO HEIGHT RESTRICTION Prepared
More informationOPTIBAR DP 7060 Supplementary Instructions
OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,
More informationINSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon
INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate IECEx
More informationApprovals, Certificates and Conditions
PROCESS ANALYSERS SERVOTOUGH SpectraExact (2500 series) Process Gas Analysers Approvals, Certificates and Conditions Part Number: Revision: Language: 02500008C 4 UK English This page intentionally blank
More informationErik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories
Hazardous Locations: Understanding the Basics of Global Compliance Requirements Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories DISCLAIMER/ TERMS OF USE: THE INFORMATION
More informationVERSAFLOW VORTEX Supplementary instructions
VERSAFLOW VORTEX Supplementary instructions Vortex flowmeter Equipment category II 2G CONTENTS VERSAFLOW VORTEX 1 Safety instructions 3 1.1 General notes... 3 1.2 EC conformity... 3 1.3 Approval according
More informationINSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER
INSTRUCTIONS FOR SAFE OPERATIONS LM000 EXPLOSION PROOF LASER DISTANCE METER www.cord-ex.com CONTENTS READ THIS FIRST Read This First Liability Trademark Information Product Information Special Conditions
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-d Edition 09/208 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4
More informationHazardous Areas - EXPLOSIONPROOF SOLENOIDS
Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExTS110D Flameproof Sontel 1) Introduction The BExTS110D is a flameproof Sontel telephone sounder which is certified to the meet the requirements of the ATEX directive
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MNUL (TEX / IECEx) ExG21D Flameproof Xenon eacon For use in Flammable Gas and Dust tmospheres 1) Introduction The ExG21D is a flameproof beacon certified to meet the requirements of the TEX
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:2 Status: Current Date of Issue: 2014-05-14
More informationIECEx Certificate of Conform ity
IECEx Certificate of Conform ity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationApproval of Ex (Electrical) Equipment for use/installation in Hazardous Areas.
Approval of Ex (Electrical) Equipment for use/installation in Hazardous Areas. Requirement under Rule 102 of the Petroleum Rules, 2002 lays down that no electrical wiring shall be installed and no electrical
More informationCertification Supplement Manual
PROCESS ANALYSERS SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 2 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EC DECLARATION OF CONFORMITY
More informationIECEx Certificate of Conformity
Certificate of Conformity: IECEx SIR 09.0111 http://iecex.iec.ch/iecex/iecexweb.nsf/fc034777969a786bc1256d42005bd791/f076962... Page 1 of 3 22/01/2010 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:2 Status: Current Certificate history:
More informationNON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS
NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS The ATEX Directive consists of two EU Directives, ATEX Directive 2014/34/EU and ATEX Directive 99/92/EC. ATEX Directive 2014/34/EU embodies the European minimum
More informationDräger Polytron 5100 EC Detection of toxic gases and vapors
Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT
More informationFixed Gas Detection System/Meridian CERTIFICATION
The marking shall include 2 Wire Aluminum Transmitter 3/4 Wire Aluminum Transmitter 2 Wire Stainless Steel Transmitter (PN: 096-3521) (PN: 096-3522) (PN: 096-3525) Ex db [ia Ga] IIC T4 Gb Ex db [ia Ga]
More informationVQ600 Datasheet. Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) FEATURES TECHNICAL SPECIFICATION OPERATION
SGX Europe Sp. z o.o. VQ600 Datasheet Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) The VQ600 Series is designed to detect and monitor various gases in the range 0 to 100% LEL for combustible
More information4) Intrinsic Safety Certification
INSTRUCTION MANUAL Minialert Intrinsically Safe Round Combined Unit Section Volume Control Tone Generator S2 S3 Tone Selection Switches Fig 1 Simplified block diagram The combined unit is CE marked for
More informationINSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres
INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG05D-SIL is a flameproof beacon which is certified
More informationHazLoc Essential Guides:
HazLoc Essential Guides: Intertek Deeside Lane, Chester, CH1 6DD UK hazloc@intertek.com 01244 882590 www.intertek-hazloc.com Introduction This white paper aims to clarify ATEX Technical Files. As a Notified
More informationIECEx Certificate of Conformity
Page 1 of 5 INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:1 Status: Current Certificate
More informationNot to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT. BU-110 and BV-110 Loop Based Displays
Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT Project No: 0003053331 Supplements Project No.: 3034449 Class: 3010 Product Name: BU-110 and BV-110 Loop
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 17065:2012 to provide product conformity certification Unit 16-18 Abenbury Way Wrexham Industrial Estate Wrexham LL13 9UZ United Kingdom Contact:
More informationCertificate Surveillance audit
Certificate Surveillance audit The quality management System of the Company Manufacturer: R. STAHL Schaltgeräte GmbH Address: Am Bahnhof 30, 74638 Waldenburg, Germany 7 Site(s) of manufacture: R. STAHL
More informationIECEx Certificate of Conformity
Page 1 of 4 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate
More informationCertification Supplement Manual
SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 5 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EU DECLARATION OF CONFORMITY 3 EUROPEAN
More informationEC TYPE EXAMINATION (MODULE B) CERTIFICATE
EC TYPE EXAMINATION (MODULE B) CERTIFICATE This is to certify that: LLOYD'S REGISTER VERIFICATION LIMITED (LRV), specified as a notified body under the terms of The Merchant Shipping (Marine Equipment)
More informationCertification Supplement Manual
PROCESS ANALYSERS SERVOTOUGH Oxy Gas Analyser Certification Supplement Manual Part Number: 01910008B Revision: 9 Language: UK English This page intentionally blank SERVOTOUGH Oxy Certification Supplement
More informationEUROPUMP ATEX Guideline Part II
EUROPEAN ASSOCIATION OF PUMP MANUFACTURERS ASSOCIATION EUROPÉENNE DES CONSTRUCTEURS DE POMPES EUROPÄISCHE VEREINIGUNG DER PUMPENHERSTELLER EUROPUMP ATEX Guideline Part II Application of the EC-Guidelines
More informationReport on the activities of the ATEX consultant. Xavier Lefebvre. Contract : CENELEC/NA Consultant/2013-1
Report on the activities of the ATEX consultant Xavier Lefebvre Contract : CENELEC/NA Consultant/2013-1 Period covered: from 1 January 2013 to 1 July 2013 1. Attended meetings Date Subject Location 2013.01.28
More informationIR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining
IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining FEATURES * Configured for carbon dioxide (IR11BD, IR21BD), hydrocarbons (,,, ) or acetylene
More informationATEX/05/1/7. In detail:
ATEX/05/1/7 This paper contains available and signed ExNBG clarification sheets and is subdivided in 4 sections. Please be aware that this item will require a large part of the time available for the meeting.
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationAPPROVAL REPORT. J.l. 3ZOA9.AX
NOT to be distributed outside the FACTORY MUTUAL SYSTEM, except by CLIENT. APPROVAL REPORT MODEL FA-249-HA and FA-250-HA MARINE SIGNAL LANTERN USING MODEL APCL-5 FLASHCHANGER Part Numbers 8087-0122, 8087-0123,
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx UL 08.0012X issue No.:5
More informationAustralian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529
AS 60529 2004 IEC 60529 Ed 2.1:2001 AS 60529 Australian Standard Degrees of protection provided by enclosures (IP Code) This Australian Standard was prepared by Committee EL-026, Protective Enclosures
More informationExp, pressurized systems
Exp, pressurized systems ATEX approved Principle, requirements and recommendation Exp, explosion protected systems The principle of a pressurized apparatus The entry of a surrounding atmosphere into the
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx UL 13.0039U issue No.:1
More information805QS Pressure Switch-Transmitter
805QS Pressure Switch-Transmitter These instructions provide information for installation, process connection, n, electrical connection, operation and maintenance of the 805QS pressure switch-transmitter.
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:0 Certificate history: Status: Current
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: IECEx INE 10.0013X Current
More informationDräger Polytron 5100 EC Detection of toxic gases and vapors
Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen It uses a high performance
More informationOfficine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0
Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:
More informationIECEx Certificate of Conformity
Certificate : IECEx CSA 09.0001X Page 1 of 5 INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue
More informationLamp Supply (Recommended)
SGX Europe Sp. z o.o. IR600 Datasheet Infrared Gas Sensor for Hazardous Areas (Fixed Systems) The IR600 Series gas sensors are designed to detect and monitor the presence of CO 2, hydrocarbons and acetylene
More informationATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC
Quick Introduction to TÛV Denmark TÜV Denmark - is a part of the TÜV NORD Group a global Organisation f Certification and Inspection of: Quality Management Systems, Products, Processes and Qualification
More informationFlexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.
Flexible Schedule of Accreditation SIRA CERTIFICATION SERVICE. Issue No: 072A Issue date 23 rd March 2018 Unit 6 Hawarden Industrial Park Hawarden, CH5 3US, United Kingdom Contact: Mr A Myler Tel: +44
More informationA guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.
A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here Introduction Potentially Explosive Atmospheres exist where there is a risk
More informationGUIDELINES. the Interpretation of
GUIDELINES on the Interpretation of ATEX Directive Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres Directive 94/9/EC for the Valve and Actuator Industry prepared
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No. : Status: Date of Issue: Applicant:
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 17065:2012 to provide product conformity certification Newport Business Park New Port Road Ellesmere Port CH65 4LZ United Kingdom Contact:
More informationHYTEK ATEX APPROVED BUND ALARM
Technical Data HYTEK ATEX APPROVED BUND ALARM BA3A.BP Applies to the following models only: - BA3A.BP - BA3A.BS - BA3A.BSP - BA3A.BAB Please read carefully before commencing installation Registered Office:
More informationCertificate of Compliance
Certificate of Compliance Certificate: 1055868 (LR 44092) Master Contract: 152450 Issued to: Micro Motion Incorporated 7070 Winchester Cir Boulder, CO 80301 USA Attention: Ray C. Stengl The products listed
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-nA Edition 08/207 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Accessories BF 12 Mounting flange, 12 mm Technical Data specifications Switching element function NAMUR, NO Rated operating distance s n 4 mm Installation non-flush
More informationIR15 Dual Gas Series Datasheet
SGX Europe Sp. z o.o. IR15 Dual Gas Series Datasheet Infrared Dual Gas Sensor for Hazardous Environments (Portable and Fixed Systems) The SGX infrared sensors use the proven Non-Dispersive Infrared (NDIR)
More informationRegulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D
Regulated Ex-Heater HEX5-1.08 with internal controller, HEX5-2.08 with external controller II 3 G II 3 D Instruction Manual Version 1.02.00 Dear customer, we have made up this operating manual in such
More informationApproval Standard for Electric Equipment for use in Hazardous (Classified) Locations General Requirements
Approval Standard for Electric Equipment for use in Hazardous (Classified) Locations General Requirements Class Number 3600 November 1998 2002 FM Approvals LLC. All rights reserved. Foreword FM Approvals
More informationEXNBG CLARIFICATION/DECISION SHEETS NOTED BY THE ATEX STANDING COMMITTEE STATUS ON DECEMBER 2009
EXNBG CLARIFICATION/DECISION SHEETS NOTED BY THE ATEX STANDING COMMITTEE STATUS ON DECEMBER 2009 Number ExNB/CS/ DS (1) Edition Subject / Keywords 98/06/001 1.0 Certification of a torch according to EN
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...
More informationDräger Polytron 5700 IR Detection of flammable gases and vapours
Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive
More informationInductive slot sensor
0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output
More informationMAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL
MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL Contents IMPORTANT... 3 General Description... 4 General Operation... 4 Changing Factory Settings... 4 Alarm Type... 4 Check Interval...
More informationDräger Polytron 5200 CAT Detection of flammable gases and vapours
Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion
More informationFlexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.
Flexible Schedule of Accreditation SIRA CERTIFICATION SERVICE. Issue No: 63A Issue date 16 th June 2015 Unit 6 Hawarden Industrial Park Hawarden, CH5 3US, United Kingdom Contact: Mr A Myler Tel: +44 (0)1244
More informationCO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE
CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 PPE-R/00.017 Version 2 RECOMMENDATION FOR USE Number of pages: 5 Approval stage : Approved on : Origin : Horizontal Committee, C2D Ad hoc group
More informationRULEBOOK ON ELECTROMAGNETIC COMPATIBILITY
RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY ("Official Gazette of RS, issue No. 13/2010) I INTRODUCTION Scope Article 1 This Rulebook stipulates the essential requirements that shall be met with regard to
More informationDSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor
Product ID Type # Product # Drawing # DSF 1210.00 SHV Ex-atex (2m) 374Z-05066 110428F1 DSF 1210.00 SHV Ex-atex (5m) 374Z-05176 110428F1 DSF 1210.00 SHV Ex-atex (10m) 374Z-05590 110428F1 DSF 1410.00 SHV
More informationIECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements
ExTR Reference Number...: ExTR Free Reference Number...: 223531 Compiled by + signature (ExTL)...: Reviewed by + signature (ExTL)...: NO/NEM/ExTR12.0018/00 Stig André Norheim Arne Hortman Date of issue...:
More informationFUNCTIONAL SAFETY CERTIFICATE
FUNCTIONAL SAFETY CERTIFICATE This is to certify that the X5000 & S5000 Fixed Gas Detector Range MSA The Safety Company manufactured by General Monitors 1000 Cranberry Woods Drive 26776 Simpatica Cir Cranberry
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK SIRA Certification Service Accredited to ISO/IEC 17065:2012 to provide product conformity Unit 6 Hawarden Industrial Park Hawarden Deeside
More informationINTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME)
INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME) To: Members of the Management Committee ExMC Introductory
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationREGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC
EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or
More informationAnnubar Flowmeter Series
Reference Manual Appendix B Approvals Annubar Flowmeter Series Hazardous Locations Installations.................. page B-1 Rosemount 3051SFA Product Certifications.......... page B-1 Rosemount 3095MFA
More informationVQ600 Series Combustible Gas Sensing Head
VQ600 Series Combustible Gas Sensing Head FEATURES * Designed for fixed gas detection systems * Diffused gas sampling * Accessories available * Rugged construction * LEL and % volume monitoring * Three
More informationINSTRUCTION & SERVICE MANUAL
INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following
More informationImplementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -
TF N 530 Rev.2 2012-04-13 CONSTRUCTION SECTOR STANDARDIZATION GUIDANCE DOCUMENT Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA - 1 Drafting
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:1 Status:
More informationE2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.
E2S Datasheet 1.2.1 v10a ISmA1 ISminialarm The ISmA1 is a compact, 100dB(A) alarm sounder. Approvals include ATEX, IECEx and GOSTR for Zone 0 applications and FM approval for Class I Division 1 and Class
More informationSeat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.
ATEX SOLUTIONS In order to apply a single level for health and safety requirements and to overcome barriers of trade within Europe, national regulations for explosion prevention were harmonized in 1975
More information1510 Side Mounted Level Switch
1510 Side Mounted Level Switch General Instructions The SOR 1510 Level Switch mounts into the side of a vessel. Electric switching action is provided by the float moving a magnet into the field of a hermetically
More informationIR25 Dual Gas Series Datasheet
SGX Europe Sp. z o.o. IR25 Dual Gas Series Datasheet Infrared Dual Gas Sensor for Mining (Portable and Fixed Systems) The SGX infrared sensors use the proven Non-Dispersive Infrared (NDIR) principle to
More informationINFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY
INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY >OLYL >H]LSLUN[O 4H[[LYZ SMOKELESS FLARE MONITOR Smokeless Flare Monitor (FM) Smokeless flares incinerate flammable hazardous
More informationIR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.
IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol. FEATURES Two active gas channels for simultaneous detection of carbon dioxide and methane (or other hydrocarbons)
More informationIR1 Single Gas Series Datasheet
SGX Europe Sp. z o.o. IR1 Single Gas Series Datasheet Infrared Single Gas Sensor for Hazardous Environments (Portable and Fixed Systems) The SGX infrared sensors use the proven Non-Dispersive Infrared
More informationPrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions
PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions Because every life has a purpose PrimaX IR Gas Transmitter Every feature of the SIL 2 engineered PrimaX IR Gas Transmitter
More information