50(394) IEC. ore content meter ore sorting equipment overvoltage (of a Geiger-Müller county tube)...

Size: px
Start display at page:

Download "50(394) IEC. ore content meter ore sorting equipment overvoltage (of a Geiger-Müller county tube)..."

Transcription

1 INDEX A (absorbed) dose ratemeter absorption band (of a scintillator) acceptance test accident monitor activator actuated equipment actuation device ADC (abbreviation) airborne dust or Articulates monitor air-equivalent ionization chamber air-equivalent scintillation detector air sampler albedo neutron dosemeter all or nothing radiation relay alpha-cup amplifier amplifying semiconductor detector amplitude-to-time converter analogue offset analogue signal analogue-to-digital converter anticoincidence apparatus assembly (of nuclear instrumentation) audio-radiation prospecting indicator automatic power cutback system automatic test avalanche breakdown (of a junction) avalanche voltage B back-scatter soil density meter back-scatter thickness meter background level (of a measuring assembly) beryllium prospecting meter beta-gamma doorway monitor bin binary signal (body) radiocartograph boron coated semiconductor detector boron trifluoride ionization chamber boron trifluoride proportional counter tube boron-lined counter tube boron-lined ionization chamber Bragg-Gray cavity Bragg-Gray cavity ionization chamber breakdown (of a reverse biased PN junction) bubble chamber burn-up life (of a neutron detector) burst (in an ionization chamber) bus C calorimetric detector CAMAC CAMAC crate-controller Campbell system for neutron monitoring capacitor ionization chamber carbon to hydrogen ratio meter Cerenkov detector Cerenkov effect failed element monitor channel activity comparator characteristic curve (of a Geiger-Müller counter tube) charcoal radon cup charge carrier charge collection time (of a semiconductor detector) charge emission detector checking source chemical detector clad temperature computer clipping time cloud chamber coarse control element coarse control member coaxial semiconductor detector coefficient of variation coincidence circuit coincidence resolving time collecting electrode collection efficiency (of a photomultiplier tube) compensated ionization chamber compensated semiconductor compensated semiconductor detector compensation factor (of a compensated ionization chamber) compensation ratio (of a compensated ionization chamber) Compton continuum computer log conductivity meter container load activity meter container sorting mine-head equipment control member control member drive mechanism (of a nuclear reactor) control rod conventionally true value of a quantity conversion quantum efficiency (of a photocathode) converter (for neutron detectors) coolant gross activity monitor coolant leakage measuring assembly corona counter tube count counter tube counting assembly counting loss (of a counting assembly) counting rate crate (for nuclear instrumentation) critical field (of a counter tube) criticality (risk) monitor cross-over walk crystal conduction detector current ionization chamber D DAC (abbreviation) dark current (of a photomultiplier tube) dead layer (of a semiconductor detector) dead time (for analyzer) dead time (of a Geiger-Müller counter tube) dead time correction

2 delayed neutron failed element monitor density meter depletion layer (in a semiconductor detector) detection efficiency detection limit detection threshold detector efficiency difference ionization chamber differential de/dx semiconductor detector differential non-linearity (of a measuring assembly) diffused junction detector diffusion chamber digital offset digital signal digital-to-analogue converter digitized signal dip counter tube dip detector discharge noise (of a corona counter tube) discriminator discriminator curve dose equivalent meter dose equivalent monitor dose equivalent ratemeter dosemeter dosemeter charger dosemeter charger-reader dosemeter reader dosimeter driven device dynamic range dynode E effective range of measurement electret ionization chamber electric penetration assembly (of a nuclear reactor) electrometer electron collection pulse chamber electron collection time electron multiplier electron semiconductor electrostatic collector failed element monitor emergency shutdown rod emergency shut-down safety system emission band (of a scintillator) emission spectrum (of a scintillator) end effect (of a counter tube) energy conversion efficiency (of a scintillator) energy resolution (of a radiation spectrometer) environmental radioactive aerosol monitor equipment equivalent noise charge error of indication escape peak etched track detector evaporated sample liquid activity meter external cathode counter tube v9-15 extrapolation ionization chamber extrinsic semiconductor F fading failed element indicator failed element monitor false coincidence FASTBUS film dosemeter fine control element fine control member fission counter tube fission ionization chamber fission product separator failed element monitor fission products poisoning predictor fission semiconductor detector flat counter tube fluid flowmeter fluorescence following level meter forward current (of a junction) forward direction (of a PN junction) forward voltage (of a junction) free air ionization chamber full width at half maximum function unit FWHM (abbreviation) G gain (of a photomultiplier tube) gain (of an electron multiplier in a photomultiplier tube) gas-flow detector gas-flow ionization chamber gas-flow neutron fluence rate measuring assembly gas multiplication gas multiplication factor gas radioactivity meter Geiger-Müller counter tube Geiger-Müller region Geiger-Müller threshold grid ionization chamber guard ring guard-ring semiconductor detector H hand or foot contamination warning assembly hand-foot-clothing radioactive contamination monitor heavy-light water heat exchanger leak monitor heavy water content meter helium counter tube high purity semiconductor detector hole hole semiconductor I I-type semiconductor implanted junction detector in-core neutron fluence rate mapping system in-core temperature measuring sensor in-core temperature measuring system instantaneous availability instrument efficiency (for a source)

3 integral non-linearity (of a measuring assembly) integrating ionization chamber internal gas detector intrinsic background level intrinsic semiconductor inversion layer ion collection pulse chamber ion collection time ionisation chamber π ionization chamber π ionization chamber ionization chamber with internal gas source ionization current ionisation detector ionization track J junction L latency time leakage current level meter light guide light sensitivity (of a photomultiplier) light sensitivity non-uniformity (of a photomultiplier) (linear) conversion gain linear detector liquid counter tube liquid radioactivity meter liquid-wall ionisation chamber lithium coated semiconductor detector lithium drifted semiconductor detector live time M mass spectrometer maximum acceptable irradiation rate (of a detector) minimum detectable quantity (of a radiation measuring assembly) mobility (of a charged particle) module mosaic semiconductor detector multifunction semiconductor detector multiplier phototube N N-type semiconductor neutron thermopile NIM noble gas effluent monitor for accident conditions noise diagnostic system (of a nuclear reactor) non-linear detector normal shut-down safety assembly nuclear emulsion nuclear instrumentation nuclear magnetic resonance spectrometer nuclear reactor instrumentation O off-line on-line "on-off" level indicator ore content meter ore sorting equipment overvoltage (of a Geiger-Müller county tube) P P-type semiconductor paralysis time particle fluence rate indicator particle fluence rate monitor particle fluence ratemeter peak-to-compton ratio peak-to-total ratio period meter personal dosemeter phosphorescence photocathode sensitivity photoelectric peak photofraction photographic dosemeter photoluminescence dosemeter photomultiplier tube photon emission curve (of a scintillator) pile-up (in a counting assembly) planar semiconductor detector plateau plateau relative slope PMT (abbreviation) PN junction pole-zero cancellation position-sensitive semiconductor detector potential alpha energy meter potential alpha energy monitor power measuring assembly based on activation probe (of a radiation meter) programmed action safety assembly proportional counter tube proportional region protection system (of a nuclear reactor) pulse coincidence pulse ionization chamber pulse ionisation detector (pulse) selector pulse shaper Q qualification test quenching quenching circuit quenching gas R (radiation) analyser radiation bore-hole logging meter (radiation) charge meter radiation compensated semiconductor detector radiation detection assembly radiation detection sub assembly radiation detector π radiation detector π radiation detector (radiation) exposure indicator (radiation) exposure meter (radiation) exposure monitor (radiation) exposure rate indicator

4 (radiation) exposure ratemeter radiation gauge (radiation) indicator radiation meter (radiation) monitor radiation prospecting meter radiation protection instrumentation (radiation) spectrometer (radiation) warning apparatus radioactive aerosol meter radioactive air contamination indicator radioactive air contamination meter radioactive air contamination monitor radioactive surface contamination indicator radioactive surface contamination meter radioactive surface contamination monitor radioactive well logging (radio)activity meter radio-bioassay meter radiochromatograph radio-defect detector radioluminescent detector (radio) thermoluminescence radon content meter random coincidence rapid shut-down system ratemeter reactivity meter reactor safety fuse reader for photoluminescence dosemeter reader for thermoluminescence dosemeter real time recoil nuclei counter tube recoil nuclei ionisation chamber recoil proton counter tube recoil proton ionisation chamber recovery time redundancy (of means) reference point of an assembly reference source region of limited proportionality relative error relative intrinsic error reliability residual current (of a detector) resolution (of a radiation measuring assembly) resolving time resolving time correction response (of a radiation measuring assembly) response pulse duration (of a photomultiplier tube) response time (of a measuring assembly) reverse current (of a junction) reverse direction (of a PN junction) reverse voltage (of a junction) rise time (of a measuring assembly) routine test S safety actuation system (safety) a arm system safety element safety group (of a nuclear reactor) (safety) interlock system safety logic assembly safety mechanism (of a nuclear reactor) safety member safety monitor safety parameter display system safety system (of a nuclear reactor) safety system support features sampling monitor sampling time (of a detection assembly) saturation current (of an ionization chamber) saturation curve (of a current ionization chamber) saturation voltage (of an ionisation chamber) scaler scaling factor (of a scaler) scinteblock scintillating material scintillation scintillation chamber scintillation decay time scintillation detector scintillation duration scintillation fall time scintillation integrated block scintillation rise time scintillator selectivity (of a detector) self-powered detector self-quenched counter tube semiconductor semiconductor detector sensitive lining (of a neutron detector) sensitive material (of a neutron detector) sensitive time (of a track chamber) sensitive volume (of a detector) sensitivity (of a measuring assembly) settling time (of a measuring assembly) shim element shim member single channel analyzer spark chamber spark detector SPDS (abbreviation) spectral response curve (of a photocathode) spectral sensitivity (of a photomultiplier) spectrum stabilizer spurious count stability (of a radiation measuring assembly) sub-assembly surface battier detector surface-barrier contact system (of nuclear instrumentation) T test duration test initiation (in nuclear instrumentation) test input test interval test termination (in nuclear instrumentation) thermal power measuring assembly thermoluminescence dosemeter thermoluminescence dosimetry system thermoluminescent detector thermoluminescent material thickness meter thimble ionisation chamber thin wall counter tube threshold of response (to pulses)

5 time-of-flight (of a particle) time-to-amplitude converter time-to-digital converter tissue activity meter tissue-equivalent ionization chamber tissue-equivalent scintillation detector TLD (abbreviation) total absorption detection efficiency total absorption detector efficiency total absorption peak total depletion voltage (of a semiconductor detector) totally depleted semiconductor detector Townsend avalanche track chamber transfer function meter transit time (in a photomultiplier tube) transit time jitter (in a photomultiplier tube) transmission density meter transmission semiconductor detector transmission soil density meter transmission thickness meter true coincidence U useful life (of a detector) (U.V.) photoluminescent detector W wall effect wall-less ionization chamber warning system (of a nuclear reactor) wavelength shifter well-type detector well-type ionization chamber whole-body gamma spectrum analyzer whole-body internal contamination meter Wilson cloud chamber window (of a detector) window counter tube windowless multiplier phototube windowless photomultiplier tube X X-ray fluorescence thickness meter

LECTURE 11. Dr. Teresa D. Golden University of North Texas Department of Chemistry

LECTURE 11. Dr. Teresa D. Golden University of North Texas Department of Chemistry LECTURE 11 Dr. Teresa D. Golden University of North Texas Department of Chemistry C. Detectors Properties of Detectors -quantum counting efficiency -linearity -energy proportionality -resolution C. Detectors

More information

Today s Outline - September 12, C. Segre (IIT) PHYS Fall 2016 September 12, / 21

Today s Outline - September 12, C. Segre (IIT) PHYS Fall 2016 September 12, / 21 Today s Outline - September 12, 2016 C. Segre (IIT) PHYS 570 - Fall 2016 September 12, 2016 1 / 21 Today s Outline - September 12, 2016 Detectors C. Segre (IIT) PHYS 570 - Fall 2016 September 12, 2016

More information

Experimental Particle Physics PHYS6011 Joel Goldstein, RAL

Experimental Particle Physics PHYS6011 Joel Goldstein, RAL Experimental Particle Physics PHYS6011 Joel Goldstein, RAL 1. Introduction & Accelerators 2. Particle Interactions and Detectors (1/2) 3. Collider Experiments 4. Data Analysis Charged Particle Detectors

More information

Portable Survey Instruments NISP-RP-01

Portable Survey Instruments NISP-RP-01 NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection NISP-RP-01 This is an industry document for standardizing radiation protection processes used by supplemental radiation protection technicians.

More information

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection Level 3 Information Use NISP-RP-001 Industry Approval Date: September 14, 2018 This is an industry document for standardizing radiation protection

More information

Gaseous detectors. 1

Gaseous detectors.  1 Gaseous detectors Very important class of detectors with many applications charged particle, x- & gamma rays, visible light detection applications in many areas of research, & commercial particle & nuclear

More information

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S)

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S) LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S) Ganibu Dambis 26, P.O.Box 33 Riga, LV-1005, LATVIA Tel. (+371)6738-3947 Fax:(+371)6738-2620 office@bsi.lv www.bsi.lv CONTENTS INTRODUCTION...

More information

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE LEARNING OBJECTIVES: 2.19.01 Describe the features and specifications for commonly used laboratory counters or scalers: a. Detector type b. Detector shielding c. Detector window d. Types of radiation detected

More information

Identify the following features and specifications for the ESP1

Identify the following features and specifications for the ESP1 LEARNING OBJECTIVES: 2.17.01 List the factors which affect an RCT's selection of a portable contamination monitoring instrument, and identify appropriate instruments for contamination monitoring. (Also

More information

February 12, PHY357 Lecture 11. Experimental Methods. Accelerators. Particle Interactions. Particle Detectors. Full experiment (eg.

February 12, PHY357 Lecture 11. Experimental Methods. Accelerators. Particle Interactions. Particle Detectors. Full experiment (eg. PHY357 Lecture 11 Experimental Methods Accelerators Particle Interactions Particle Detectors Full experiment (eg. ATLAS) Introduction! Several different general classes of particle detectors (sensors)!

More information

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES:

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES: LEARNING OBJECTIVES: 2.17.01 List the factors which affects an RCT's selection of a portable contamination monitoring instrument. 2.17.02 Describe the following features and specifications for commonly

More information

Technical Manual Ionisation Chamber MUSIC80

Technical Manual Ionisation Chamber MUSIC80 Technical Manual Ionisation Chamber MUSIC80 Entwicklungsbüro Dr. R. Schneider Lärchenstraße 9 85640 Putzbrunn Tel: 089 608 533 71 Fax: 089 608 533 72 E-Mail: robert@schneider.net Entwicklungsbüro Andreas

More information

Measurement Devices. Topic 5 - Audio 56

Measurement Devices. Topic 5 - Audio 56 Topic 5 - Audio 56 Other Classifications Passive devices: Air diffuses in No power required for sampling Active devices: Requires power Pumps air through filter Key Points - Devices What lab sees: Different

More information

Using downhole probing for real-time grade estimation for uranium exploration and mining

Using downhole probing for real-time grade estimation for uranium exploration and mining February 2015 Using downhole probing for real-time grade estimation for uranium exploration and mining Andrew Fitzpatrick Chief Geophysicist cameco.com Radiation 101 2 Using downhole probing for Uranium

More information

Detecting Radiation. Protection through Detection. February Animations in this training work best in Windows XP

Detecting Radiation. Protection through Detection. February Animations in this training work best in Windows XP Saudi Arabia : info_ksa@magusintl.com U.A.E : info_uae@magusintl.com Detecting Radiation Animations in this training work best in Windows XP February 2006 Why Detect Radiation Today? Medicine Imaging Cancer

More information

Measurement system for detection of Radon in building

Measurement system for detection of Radon in building Measurement system for detection of Radon in building Outline Properties of Radon Detection of ionised particles Measurement system for radon Properties of Radon Radon is a gaseous isotope ( 222 Rn) with

More information

Radiation Control and Monitoring System on the HTTR

Radiation Control and Monitoring System on the HTTR Radiation Control and Monitoring System on the HTTR Y. Minowa, T. Nakazawa, H. Kikuchi, T. Nomura and N. Sato Japan Atomic Energy Research Institute Oarai Research Establishment, Oarai-machi, Ibaraki-ken

More information

HEALTH AND SAFETY MANUAL

HEALTH AND SAFETY MANUAL HEALTH AND SAFETY MANUAL Title: Ionizing Radiation Approved by: Greg Savoy Rev. 3/1/13 1.0 Purpose The purpose of this safety policy is to establish guidelines for the protection and safety of Compay employees

More information

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor FEATURES: HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS WORLD S ONLY PAG-LEVEL WATER MONITOR MEASURES AT OR BELOW EPA/DHS PAG LEVELS (EPA s PROTECTIVE ACTION GUIDELINE LEVELS) REAL TIME, IN-LINE, CONTINUOUS

More information

Semiconductor Radiation Detectors

Semiconductor Radiation Detectors Gerhard Lutz Semiconductor Radiation Detectors Device Physics With 167 Figures and 11 Tables Contents 1. Introduction 1 Part I: Semiconductor Physics 5 2. Semiconductors 7 2.1 Crystal Structure 7 2.2 Energy

More information

dewar or an electrically powered cooler. The sensitive detector surfaces are thus protected from moisture and condensable contaminants.

dewar or an electrically powered cooler. The sensitive detector surfaces are thus protected from moisture and condensable contaminants. Germanium Detectors The Company Canberra Industries is the world's largest manufacturer of nuclear radiation detection and analysis systems. In order to better serve our customers worldwide, Canberra operates

More information

EVALUATION OF A NEUTRON-PHOTON SHIELD FOR TRANSURANIC (TRU) WASTE CONTAINERS

EVALUATION OF A NEUTRON-PHOTON SHIELD FOR TRANSURANIC (TRU) WASTE CONTAINERS EVALUATION OF A NEUTRON-PHOTON SHIELD FOR TRANSURANIC (TRU) WASTE CONTAINERS M. Gallegos, R. Ruby, E. J. Sullivan, R. J. Wishau Los Alamos National Laboratory ABSTRACT The Los Alamos National Laboratory

More information

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110 TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110 APPLICATION NOTE CC-107 Introduction This purpose of this document is to detail the advanced, state of the art features TSI has incorporated in the design

More information

Maximize safety and productivity. Thermo Scientific Nuclear Power Radiation Detection and Monitoring Solutions

Maximize safety and productivity. Thermo Scientific Nuclear Power Radiation Detection and Monitoring Solutions Maximize safety and productivity Thermo Scientific Nuclear Power Radiation Detection and Monitoring Solutions Monitoring solutions to optimize safety, efficiency and compliance Our years of expertise and

More information

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System FEATURES: HIGH GAMMA SENSITIVITY MULTI-CHANNEL ANALYZER (MCA) WORKS WITH VARIETY OF PROBES RADIONUCLIDE LIBRARY TAILORED TO CUSTOMER REQUEST SIMULTANEOUSLY MEASURES ; DISPLAYS; ALARMS 1-3 SEPARATE DETECTORS

More information

A Continuous Air Monitoring Sampler for 125 I - RIS-125

A Continuous Air Monitoring Sampler for 125 I - RIS-125 A Continuous Air Monitoring Sampler for 125 I - RIS-125 S.Levinson, I.Belaish, T.Kravchik, U.German, O.Pelled, Y. Laichter, Y.Mazor, U.Wengrowicz, E.Dolev, H.Assido, D.Tirosh Nuclear Research Center Negev,

More information

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions. Personal Alpha/Beta Continuous Air Monitor (CAM) The pocamon (personal online continuous air monitor) monitors continuously the breathing air to detect airborne radioactive aerosols (LLRD). Typical application

More information

22 Radiological and Environmental Monitoring Systems Functions, Basic Configuration, and Interfaces

22 Radiological and Environmental Monitoring Systems Functions, Basic Configuration, and Interfaces 22 Radiological and Environmental Monitoring Systems 22.1 Functions, Basic Configuration, and Interfaces 22.1.1 Functions 22.1.1.1 Radiological Monitoring and Protection System The primary function performed

More information

J. S. Baker J. A. Smith

J. S. Baker J. A. Smith % 2 ESTMATNG RADUS OF COVERAGE OF THE Y-12 PLANT CRTCALTY ACCDENT ALARR.. SYSTEM FRQM EXPEQMENTS AT %HELOS ALAMOS CRTCAL EXPERMENTS FACLTY J. S. Baker J. A. Smith Nuclear Criticality Safety Department

More information

TIMS TIMS. Thermal Ionisation Mass Spectrometry.

TIMS TIMS. Thermal Ionisation Mass Spectrometry. TIMS Thermal Ionisation Mass Spectrometry www.nu-ins.com Incorporating our field-proven Zoom lens multi-collector technology, the TIMS improves the versatility and overall performance of this long established

More information

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points Topic 4 - Audio 46 Key Points : Measures taken to increase confidence in results. Quality Assurance: Program that assures that measures are being done and in a timely manner. Precision: How close measurements

More information

LEARNING SPECIAL HAZARD DETECTION TYPES

LEARNING SPECIAL HAZARD DETECTION TYPES LEARNING SPECIAL HAZARD DETECTION TYPES JUNE 2013 COPYRIGHT CLIMATEC SPECIAL HAZARDS DETECTION TYPES EXPLAINED STAGE ONE DETECTION - ACTIVE AIR SAMPLING\\INCIPIENT AND IN- VISIBLE SMOKE STAGE AIR SAMPLING

More information

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES FEATURES: MOVING AIR FILTER AIRBORNE ALPHA LESS RADON AND BETA/GAMMA PARTICULATES RUGGED, 100% DUTY CYCLE SETTABLE ALARM HIGH THROUGH-PUT UNATTENDED OPERATION 12 WEEKS PRINTED RECORD (Optional) 4 CHANNEL

More information

Environmental Radiation Monitoring System

Environmental Radiation Monitoring System Environmental Radiation Monitoring System Toshihiro Takagi Osamu Kimura Atsushi Minagoshi 1. Introduction In order to ascertain conditions near the perimeter of a supervised area at a nuclear power plant

More information

Unattended Radiation Sensor Systems for Remote Terrestrial Applications and Nuclear Nonproliferation

Unattended Radiation Sensor Systems for Remote Terrestrial Applications and Nuclear Nonproliferation Unattended Radiation Sensor Systems for Remote Terrestrial Applications and Nuclear Nonproliferation Lodewijk van den Berg, Alan E. Proctor, Ken R. Pohl, Alex Bolozdynya and Raymond DeVito Constellation

More information

Instrumental technique (MCP detectors) - Kamalesh ( )

Instrumental technique (MCP detectors) - Kamalesh ( ) Instrumental technique (MCP detectors) - Kamalesh (02-03-2012) Schematic of a MCP detector MCP as an assembly of millions miniature SEMs Schematic of a MCP detector Microchannel Plates have a combination

More information

COMPANY PROFILE. DETECTION & MEASUREMENT OF IONIZING RADIATIONS RADIOLOGICAL MONITORING SYSTEMS HEALTH AND ENVIRONMENTAL SAFETY

COMPANY PROFILE.   DETECTION & MEASUREMENT OF IONIZING RADIATIONS RADIOLOGICAL MONITORING SYSTEMS HEALTH AND ENVIRONMENTAL SAFETY monitoring for safety COMPANY PROFILE DETECTION & MEASUREMENT OF IONIZING RADIATIONS RADIOLOGICAL MONITORING SYSTEMS ENVIRONMENTAL MONITORING HEALTH AND ENVIRONMENTAL SAFETY www.rtsinstruments.com 2 monitoring

More information

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14 FEATURES: THREE to SIX CHANNEL SIMULTANEOUS MEASUREMENT OF: BETA-GAMMA PARTICULATE IODINE NOBLE GAS ALPHA PARTICULATE TRITIUM CARBON-14 DETECTORS MORE SENSITIVE BY FACTORS OF 5-500 THAN REQUIRED BY NRC

More information

Solid State Detectors. T. Bowcock

Solid State Detectors. T. Bowcock Solid State Detectors T. Bowcock Schedule 1 Time and Position Sensors 2 Principles of Operation of Solid State Detectors 3 Techniques for High Performance Operation 4 Environmental Design 5 Measurement

More information

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

Portable Alpha/Beta Continuous Online Air Monitor (CAM) Aer 5000 Desktop Portable Alpha/Beta Continuous Online Air Monitor (CAM) The Aer5200 monitors the ambient air continuously to detect airborne radioactive aerosols (LLRD). Typical application fields are

More information

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor NEX-BETA-ABG FACILITY Drinking Water Safety Monitor FEATURES: DETECTS ALPHA, BETA AND GAMMA RADIATION AVAILABLE IN PORTABLE OR INSTALLED VERSION MEASURES AT OR BELOW EPA/DHS PAG LEVELS PROTECTIVE ACTION

More information

ORTEC DSPEC LF. High-Performance Digital Signal Processor for Gamma Spectroscopy. ... in a compact package at an economical price.

ORTEC DSPEC LF. High-Performance Digital Signal Processor for Gamma Spectroscopy. ... in a compact package at an economical price. ORTEC High-Performance Digital Signal Processor for Gamma Spectroscopy Full-featured, digital spectrometer for HPGe and NaI detectors Automatic optimization for best detector performance (patented) ORTEC

More information

Comprehensive applications of the gas flow proportional counters for Radiological Surveillance

Comprehensive applications of the gas flow proportional counters for Radiological Surveillance Comprehensive applications of the gas flow proportional counters for Radiological Surveillance D.A.R.Babu, Anand Raman, Ashokkumar P and D.N.Sharma Radiation Safety Systems Division, Bhabha Atomic Research

More information

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA - FEATURES: MOVING AIR FILTER AIRBORNE ALPHA LESS RADON AND BETA/GAMMA PARTICULATES RUGGED, 100% DUTY CYCLE SETTABLE ALARM HIGH THROUGH-PUT UNATTENDED OPERATION Up to 6 WEEKS PRINTED RECORD (Optional)

More information

Energy and Angular Responses of the Criticality Accident Alarm System Using Current-mode-operated Scintillation Detector

Energy and Angular Responses of the Criticality Accident Alarm System Using Current-mode-operated Scintillation Detector Energy and Angular Responses of the Criticality Accident Alarm System Using Current-mode-operated Scintillation Detector N. Tsujimura 1, T. Yoshida 1 and S. Mikami 1 1 Japan Nuclear Cycle Development Institute,

More information

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate Environmental and Food Measurements Lab & Individual monitoring lab Yemen Republic Population : 22 million

More information

CURRENT STATE OF THE ART IN MEASURING ENVIRONMENTAL RADON. Abstract

CURRENT STATE OF THE ART IN MEASURING ENVIRONMENTAL RADON. Abstract CURRENT STATE OF THE ART IN MEASURING ENVIRONMENTAL RADON A.C. George and N. Bredhoff Radon Testing Corporation of America Elmsford, New York Abstract According to the US EPA, radon is the leading cause

More information

W.E.T. (Water Extraction Techniques) Lab

W.E.T. (Water Extraction Techniques) Lab SNO-STR-90- /? Report on Activities W.E.T. (Water Extraction Techniques) Lab M.-Q. Liu, H. Lee and A.B. McDonald January 9, 1990 The following is a summary of work to date at Queen s on the Lucas cell

More information

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are *Instruments for optical spectroscopy: Optical spectroscopic methods are based on 6 phenomena: 1) Absorption, 2) Fluorescence, 3) Phosphorescence, 4) Scattering, 5) Emission and 6) Chemiluminescence. Typical

More information

Alpha Attenuation Due to Dust Loading. Amber E. Dailey Francis Marion University Savannah River Site

Alpha Attenuation Due to Dust Loading. Amber E. Dailey Francis Marion University Savannah River Site Alpha Attenuation Due to Dust Loading Amber E. Dailey Francis Marion University Savannah River Site Purpose The purpose of this experiment was to properly correct for the attenuation of the energy of alpha

More information

Temperature dependent Components within the Pyroelectric Detector

Temperature dependent Components within the Pyroelectric Detector 1 Introduction This application note is offered to provide some insight into how temperature affects the various components of a typical pyroelectric detector and how the effects of ambient temperature

More information

Sensors and. Transducers. D. Patranabis. Second Edition

Sensors and. Transducers. D. Patranabis. Second Edition Sensors and Transducers Second Edition D. Patranabis Sensors and Transducers Second Edition ion D. PATRANABIS Professor Department of Instrumentation and Electronics Engineering Jadavpur University Salt

More information

POSITRON EMISSION TOMOGRAPHY (PET) CENTER MONITORS

POSITRON EMISSION TOMOGRAPHY (PET) CENTER MONITORS RADIATION MONITORING SYSTEMS POSITRON EMISSION TOMOGRAPHY (PET) CENTER MONITORS Featuring: Radiological Assessment Display and Control Software (RADACS) Answers And Reports At Your Fingertips Aptec-NRC

More information

Beam Loss Position Monitoring with Optical Fibres at DELTA

Beam Loss Position Monitoring with Optical Fibres at DELTA Beam Loss Position Monitoring with Optical Fibres at DELTA Frank Rüdiger M. Körfer (DESY) W. Göttmann (HMI Berlin) G. Schmidt (DELTA) K. Wille (DELTA) 24. June 2008 Frank Rüdiger 1 Table of Content 1.

More information

American Nuclear Society (ANS)

American Nuclear Society (ANS) What s New... American Nuclear Society (ANS) Project Initiation Notification System (PINS) ANS Standards Before work on a draft can begin, a Project Initiation Notification System (PINS) form must be approved

More information

WM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA

WM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA Implementation and Performance Testing of a Sensitive Bulk Laundry Monitor for Use in Nuclear Power Stations -14004 Erik Lindberg*, Richard DelPizzo*, Tom Donohoue*, Ryan Lee**, Marc R. Looman*, E. Ray

More information

Aer 5200/5300. Data Sheet Aer 5200/5300. Portable Alpha/Beta Continuous Online Air Monitor (CAM) Closer to your application

Aer 5200/5300. Data Sheet Aer 5200/5300. Portable Alpha/Beta Continuous Online Air Monitor (CAM) Closer to your application Aer 5200/5300 Portable Alpha/Beta Continuous Online Air Monitor (CAM) The Aer5200 monitors continuously the ambient air to detect airborne radioactive aerosols (LLRD). Typical application fields are nuclear

More information

DEVELOPMENT OF LARGE AREA PLASTIC SCINTILLATION DETECTOR FOR RADIOACTIVE CONTAMINATION MONITOR

DEVELOPMENT OF LARGE AREA PLASTIC SCINTILLATION DETECTOR FOR RADIOACTIVE CONTAMINATION MONITOR DEVELOPMENT OF LARGE AREA PLASTIC SCINTILLATION DETECTOR FOR RADIOACTIVE CONTAMINATION MONITOR Katsuhito Ito, Ryohei Yanagishima, Daisuke Inui*, Tomoya Minagawa Fuji Electric Systems Co., Ltd. Fuji-machi

More information

Radiation Monitoring Equipment

Radiation Monitoring Equipment Radiation Monitoring Equipment Sharon Paulka Regional Training Course RAF 3007-1 Namibia, 17-21 August 2009 International Atomic Energy Agency Types of Monitoring Both Occupational & Environmental Require

More information

Mission 份有限公司 wwwom 先锋科技股份有限公司 www Working with our customers we identify, design and deliver low light detection solutions which solve customer probl

Mission 份有限公司 wwwom 先锋科技股份有限公司 www Working with our customers we identify, design and deliver low light detection solutions which solve customer probl 份有限公司 wwwom 先锋科技股份有限公司 份有限公司 wwwom 先锋科技股份有限公司 www Radiation detection solutions for miniaturized pager and handheld markets sensl: light detection and measurement October - 2009 www.sensl.com 1 Mission

More information

APPLICATION FOR UNITED STATES PATENT. Shieldless Detector with Two-Dimensional Directionality INVENTOR:: David E. Newman DATE:: November 9, 2018

APPLICATION FOR UNITED STATES PATENT. Shieldless Detector with Two-Dimensional Directionality INVENTOR:: David E. Newman DATE:: November 9, 2018 APPLICATION FOR UNITED STATES PATENT TITLE:: Shieldless Detector with Two-Dimensional Directionality INVENTOR:: David E. Newman DATE:: November 9, 2018 ABSTRACT Disclosed is a directional gamma ray or

More information

Maximizing safety and productivity. Nuclear Power Radiation Detection and Monitoring Solutions

Maximizing safety and productivity. Nuclear Power Radiation Detection and Monitoring Solutions Maximizing safety and productivity Nuclear Power Radiation Detection and Monitoring Solutions Growing portfolio You can depend on Thermo Scientific radiation detection and monitoring solutions to optimize

More information

Lasers Technical Seminar at Bruno Events Center on March 27 th, Next generation of SPADs - Single Photon Avalanche Detectors

Lasers Technical Seminar at Bruno Events Center on March 27 th, Next generation of SPADs - Single Photon Avalanche Detectors Lasers Technical Seminar at Bruno Events Center on March 27 th, 2012 Next generation of SPADs - Single Photon Avalanche Detectors LASER COMPONENTS, 2012 Lasers Technical Seminar, Tel Aviv March 27 th,

More information

FPD - Flame Photometric Detector

FPD - Flame Photometric Detector FPD - Flame Photometric Detector FPD Overview - The FPD detector is can be configured for 2 modes of operation, one is highly selective for Sulfur compounds and the other mode highly selective for Phosphorus

More information

Radiation Monitoring Systems

Radiation Monitoring Systems Radiation Monitoring Systems Certificate No. 3250 Contents A guide to Southern Scientific radiation monitoring systems Area Gamma & Interlock Systems (page 3) AGM3 AUTOMESS 6150 Contamination Monitors

More information

Status Report about the TPC Detector and Module at CEPC

Status Report about the TPC Detector and Module at CEPC Status Report about the TPC Detector and Module at CEPC Huirong QI On behalf of CEPC TPC subgroup, IHEP, CAS 2016.01.19, IAS, HK Content Goals and options Some considerations Preliminary simulation Hybrid

More information

The LHCb Outer Tracker: Production & Ageing studies

The LHCb Outer Tracker: Production & Ageing studies The LHCb Outer Tracker: Production & Ageing studies Kaffeepalaver MPI-K Physikalisches Institut Physikalisches Institut 1 LHC at CERN p-p collisions beam energy 7 TeV 8.6km Four experiments: Atlas, CMS,

More information

Radiation Safety and Equipment Considerations. Bonnie Meilner Regional Sales Manager LAURUS Systems Inc.

Radiation Safety and Equipment Considerations. Bonnie Meilner Regional Sales Manager LAURUS Systems Inc. Radiation Safety and Equipment Considerations Bonnie Meilner Regional Sales Manager LAURUS Systems Inc. bonnie.meilner@laurussystems.com COPYRIGHT LAURUS SYSTEMS INC - 2013 Why do you need Radiation Detectors

More information

Portable Instruments For First Response & In-Situ Analysis of Radiation

Portable Instruments For First Response & In-Situ Analysis of Radiation WWW.NATS-USA.COM Portable Instruments For First Response & In-Situ Analysis of Radiation North American Technical Services Bridging Technology With Latest in Radiation Detection Systems & Solutions The

More information

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS EML-624 A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS FOR HOMELAND SECURITY PURPOSES Paul Bailey Environmental Measurements Laboratory U.S. Department of Homeland Security 201 Varick Street,

More information

Investigation report. Radiation resistance of fire detectors under the influence of radioactive gamma radiation

Investigation report. Radiation resistance of fire detectors under the influence of radioactive gamma radiation Radiation resistance of fire detectors under the influence of radioactive gamma radiation Page 1 ST FIR/PRM1 Contents 1. Introduction.................................. 4 2. Fire detectors tested..........................

More information

Detection of Ionizing Radiation using Solar Blind Air Fluorescence

Detection of Ionizing Radiation using Solar Blind Air Fluorescence Detection of Ionizing Radiation using Solar Blind Air Fluorescence M. D. Roberts 1 Human Protection and Performance Division Defence Science and Technology Organisation DSTO TR 8 ABSTRACT This report looks

More information

Aging Analysis of Micromegas Detectors for ATLAS New Small Wheel

Aging Analysis of Micromegas Detectors for ATLAS New Small Wheel Aging Analysis of Micromegas Detectors for ATLAS New Small Wheel Melissa Quinnan August 15, 2015 Supervisor: Michele Bianco Abstract In preparation for the coming High Luminosity Large Hadron Collider

More information

Thermo Scientific Aerosol Monitor FHT 58 S Technical Specification ZT-221E

Thermo Scientific Aerosol Monitor FHT 58 S Technical Specification ZT-221E Thermo Scientific Aerosol Monitor FHT 58 S Technical Specification ZT-221E Thermo Fisher Scientific Messtechnik GmbH Frauenauracher Straße 96 91056 Erlangen Germany www.thermo.com info.rmp.erlangen@thermofisher.com

More information

DSP EC Pro. Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems

DSP EC Pro. Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems DSPEC Pro: Advancing the Art of Digital Gamma-Ray Spectroscopy The immense versatility of DSPEC Pro, brought about by the number of unique

More information

LAUNDRY MONITORING SYSTEM Model # LIM-64S

LAUNDRY MONITORING SYSTEM Model # LIM-64S LAUNDRY MONITORING SYSTEM FEATURES: HIGH SENSITIVITY EVEN TO LOW ENERGY GAMMAS 6 EACH 8 X 8 SCINTILLATORS ABOVE 4 EACH 2 X 12 NaI(Tl) BELOW AUTOMATIC CONVEYOR FOR LAUNDRY AUTOMATICALLY SEPARATES CLOTHES

More information

Antoine Drouart DSM/DAPNIA/SPhN. Köln, 5 th of December,

Antoine Drouart DSM/DAPNIA/SPhN. Köln, 5 th of December, Köln, 5 th of December, 2007 1 Basic CATS/BTD mechanics Köln, 5 th of December, 2007 2 Beam Tracking Today -Detector able to cope with a few 10 5 pps -Spatial resolution (FWHM) : 0.7mm -Time resolution

More information

Silicon Sensors S. MIDDELHOEK S.A. AUDET

Silicon Sensors S. MIDDELHOEK S.A. AUDET Silicon Sensors S. MIDDELHOEK S.A. AUDET Department of Electrical Engineering Delft University of Technology Delft, The Netherlands ACADEMIC PRESS Harcourt Brace Jovanovich, Publishers London San Diego

More information

Advanced Radiation Measurement Solutions

Advanced Radiation Measurement Solutions GE Energy Advanced Radiation Measurement Solutions Reuter Stokes Radiation Measurement Solutions GE Energy, Edison Park in Twinsburg, OH, USA World-class research and development Beginning with the first

More information

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS Steve Glander: Senior Sales Engineer All Weather, Inc. 1165 National Dr. Sacramento, CA

More information

LUDLUM MODEL AND LUDLUM MODEL ALPHA, BETA, & GAMMA DETECTORS

LUDLUM MODEL AND LUDLUM MODEL ALPHA, BETA, & GAMMA DETECTORS LUDLUM MODEL 44-9-18 AND LUDLUM MODEL 44-9-19 ALPHA, BETA, & GAMMA DETECTORS January 2018 Serial Number PR254331 and Succeeding Serial Numbers LUDLUM MODEL 44-9-18 AND LUDLUM MODEL 44-9-19 ALPHA, BETA,

More information

Relevant Radon properties

Relevant Radon properties Relevant Radon properties Radon is a natural gas and has a half life of 3.8 days. This means that if a box was full of radon gas, half of it would have decayed into something else after 3.8 days. It has

More information

Steve Kilmartin Director, Products & Markets E/One, Utility Systems Business

Steve Kilmartin Director, Products & Markets E/One, Utility Systems Business Steve Kilmartin Director, Products & Markets E/One, Utility Systems Business Generator Condition Monitor for Hydrogen Cooled Generators (GCM-X) Generator Condition Monitor for Air Cooled Generators

More information

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE Release January 2001 CONTENTS 1.0 GENERAL CHARACTERISTICS... 4 1.1 MAIN CHARACTERIS TICS... 4 2.0 USER INTERFACE (CODE C5121230)... 5 2.1 DISPLAY... 5 2.2 MEANING OF THE LEDS...

More information

White paper on the Dielectric Barrier Discharge Detectors. Introduction:

White paper on the Dielectric Barrier Discharge Detectors. Introduction: White paper on the Dielectric Barrier Discharge Detectors. Introduction: This paper is a discussion of the dielectric barrier discharge detector. As such, it is intended to provide insight into the operating

More information

MODEL AND MODEL GAS PROPORTIONAL DETECTORS. December 2016 Serial No and Succeeding Serial Numbers

MODEL AND MODEL GAS PROPORTIONAL DETECTORS. December 2016 Serial No and Succeeding Serial Numbers MODEL 43-37 AND MODEL 43-37-1 GAS PROPORTIONAL DETECTORS Serial No. 086152 and Succeeding Serial Numbers MODEL 43-37 AND MODEL 43-37-1 GAS PROPORTIONAL DETECTORS Serial No. 086152 and Succeeding Serial

More information

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR FEATURES: WORLD S ONLY PAG-LEVEL WATER MONITOR MEASURES AT OR BELOW EPA/DHS PAG LEVELS Protective Action Guideline Levels and Military Drinking Water Limits REAL TIME, IN-LINE, CONTINUOUS DETECTS ALPHAS,

More information

Victoreen. Operator Manual. Current Mode Beta Scintillation Detector, Model

Victoreen. Operator Manual. Current Mode Beta Scintillation Detector, Model Victoreen Current Mode Beta Scintillation Detector, Model 943-27 Operator Manual February 2007 Manual No. 943-27-31-1, Rev. 3 2007 Fluke Corporation, All rights reserved. Printed in U.S.A. All product

More information

COMPACT RADIOACTIVE AEROSOL MONITORING DEVICE FOR EARLY WARNING NETWORKS

COMPACT RADIOACTIVE AEROSOL MONITORING DEVICE FOR EARLY WARNING NETWORKS COMPACT RADIOACTIVE AEROSOL MONITORING DEVICE FOR EARLY WARNING NETWORKS Denis GLAVIČ-CINDRO Toni PETROVIČ Drago BRODNIK Matjaž VENCELJ Jožef Stefan Institute Ljubljana, Slovenia Steven James BELL Lindsey

More information

The End Of 3 He As We Know It

The End Of 3 He As We Know It The End Of 3 He As We Know It Richard Kouzes Pacific Northwest National Laboratory BES Detector Workshop August 1-3, 2012 PNNL-SA-89037 3 He Applications 3 He is a rare isotope with important uses in:

More information

Victoreen & 660-8

Victoreen & 660-8 Victoreen 660-6 500-100 6000-100 660-7 & 660-8 CT Probes and Phantoms Operators Manual March 2005 Manual No. 660-6-1 Rev. 3 2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A. All product

More information

2.18 Air Sampling Equipment RCT Study Guide Identify the factors that affect the operator's selection of an air sampling system.

2.18 Air Sampling Equipment RCT Study Guide Identify the factors that affect the operator's selection of an air sampling system. Learning Objectives: 2.18.01 Identify the factors that affect the operator's selection of an air sampling system. 2.18.02 Define the terms "fixed-head air sampling" and "continuous air monitoring" (CAM).

More information

Radiation Alert Frisker INTERNATIONAL

Radiation Alert Frisker INTERNATIONAL Radiation Alert Frisker INTERNATIONAL S.E. International, Inc. P.O. Box 39, 436 Farm Rd. Summertown, TN 38483 USA 1.800.293.5759 931.964.3561 Fax: 1.931.964.3564 www.seintl.com radiationinfo@seintl.com

More information

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes Measure every pulse at pps! Our new mach 5 Digital Joulemeter is designed to measure laser pulse energy up to 130,000 pps with

More information

2008 JINST 3 S The CMS experiment at the CERN LHC THE CERN LARGE HADRON COLLIDER: ACCELERATOR AND EXPERIMENTS.

2008 JINST 3 S The CMS experiment at the CERN LHC THE CERN LARGE HADRON COLLIDER: ACCELERATOR AND EXPERIMENTS. PUBLISHED BY INSTITUTE OF PHYSICS PUBLISHING AND SISSA RECEIVED: January 9, 2008 ACCEPTED: May 18, 2008 PUBLISHED: August 14, 2008 THE CERN LARGE HADRON COLLIDER: ACCELERATOR AND EXPERIMENTS The CMS experiment

More information

Alpha Analyst. Integrated Alpha Spectrometer. Radiation Safety. Amplified.

Alpha Analyst. Integrated Alpha Spectrometer. Radiation Safety. Amplified. Radiation Safety. Amplified. Alpha Analyst Integrated Alpha Spectrometer Table Top Nuclear Healthcare Homeland Security & Defense Labs and Education Industrial and Manufacturing Cabinet KEY FEATURES Completely

More information

Instruments and Consumables

Instruments and Consumables Instruments and Consumables for Academic Research Applications www.southernscientific.co.uk Contents Portable Radiation Monitoring Radhound Multi-purpose Digital Radiation Meter 3 Radhound X/E and X/I

More information

LUDLUM MODEL 44-2 GAMMA SCINTILLATOR. February 2018 Serial Number PR and Succeeding Serial Numbers

LUDLUM MODEL 44-2 GAMMA SCINTILLATOR. February 2018 Serial Number PR and Succeeding Serial Numbers LUDLUM MODEL 44-2 GAMMA SCINTILLATOR February 2018 Serial Number PR361009 and Succeeding Serial Numbers LUDLUM MODEL 44-2 GAMMA SCINTILLATOR February 2018 Serial Number PR361009 and Succeeding Serial

More information

TECHNICAL LEAFLET. The proposed instrument is an extended version of the computerized Geiger-Muller indicator PT

TECHNICAL LEAFLET. The proposed instrument is an extended version of the computerized Geiger-Muller indicator PT PROJECT 01109-4 PRELIMINARY DOCUMENT 01109-4-SD-0001-EN PT01109-4 Fast acquisition time and high sensitivity gamma and beta spectrometer to survey everyday nutrition, hygienic and household goods for radionuclides

More information

for Photonics Advanced phosphor and glass technologies for high performance alignment, detection, imaging and spectroscopy applications

for Photonics Advanced phosphor and glass technologies for high performance alignment, detection, imaging and spectroscopy applications for Photonics Advanced phosphor and glass technologies for high performance alignment, detection, imaging and spectroscopy applications custom scintillation at the core of your optical system High sensitivity

More information