1 FIRE SUPPERSSION SYSTEM WITH ALARM M.Dinakaran ¹, Cha.ArunPrakaash², P.Deepak kumar², S.Manikandaprabhu²,K.Maheswaran² ¹Associate Professor,² UG Students Department of Automobile Engineering, KSR College of Engineering, Tiruchengode Tamil Nadu, INDIA. Abstract: The recent occurrence rate of car fires is high at 12% of the total number of fire incidents, ranking second only to residential fires. Early extinction of car fires is difficult and car fires can result in complete destruction of the vehicle and significant material damage and loss of life. Various countries including the India are in process of obligating the installation of an automatic extinguishing system to protect against car fires. The automatic extinguishing system applied to automobiles needs to operate when the vehicle is in motion, so research on methods of fire detection is necessary. Therefore, in this study, an automatic extinguishing system structure is proposed for car fires in commercial automobiles. I. INTRODUCTION According to 2011 statistical data on fires compiled by the National Emergency Management Agency (NEMA), the occurrence rate of car fires was high, responsible for 12% of the total number of fire incidents, and only out ranked y residential fires. Also, as to the causes of car fires, mechanical causes (302%) are declining with electrical causes (23.7%) are increasing and are predicted to continue to increase. With the fire extinguisher equipped within automobiles law, car fires are virtually impossible to extinguish in the early phases due to flammable substances and engine overheating. Further, it is difficult to extinguish car fires by the dispatch of a fire truck within the golden time, this usually still results in massive material damage and loss of life due to complete destruction of the vehicle. A representative car fire case was the chain collision of 29 automobiles on the Seohae Grand Bridge in October 2006, which resulted in 12 burnt cars. The mandatory installment of automatic extinguishing system in building but their installment in vehicle is not obligatory. However, as car fires continue to increase in frequency, multilateral efforts centered on NEMA are being made to make such installments compulsory through legislation. International and domestic studies on automatic extinguishing systems for automobiles have been conducted on a basic level. Research on automobile related automatic extinguishing systems is being carried out by differentiating policy-related and technical-related studies. Numerous domestic studies are focused on legally mandating automatic automobile extinguishing systems. Also, the subject of technical studies on automatic extinguishing systems has mostly been fixed buildings or smart homes, rather than automobiles. Meanwhile, research overseas is being conducted on automatic extinguishing system that can automatically extinguish car fires. In this study, a system is proposed that can automatically extinguish fires in commercial automobiles. Moreover, the structure and operation method of the automatic extinguishing system have been presented considering the characteristics of commercial vehicles. Lastly, the performance of lab scale equipment simulating the proposed method was evaluated to verify its actual applicability. II. LITERATURE REVIEW & BACKGROUND The FSAI set a strategic goal to reduce by 20 percent the rate of death caused by fire related incidents from the 1998 rate by Since the Commission s inception, it has been investigating the causes of and damages resulting from residential fires. In recent years, the CPSC has conducted research into vehicle fires. Case work has been done in the fire and security association of India by CPSC field investigators. This background chapter contains information on relevant studies of past vehicle fires, means of detecting and extinguishing these fires, and current attempts to prevent the fires through education and legislation, which will help in formulating recommendations to the CPSC on the issue of vehicle fire safety. III. CLASSES OF FIRE Class A - fires involving solid materials such as wood, paper or textiles. Class B - fires involving flammable liquids such as petrol, diesel or oils.

2 Class C - fires involving gases. Class D - fires involving metals. Class E - fires involving live electrical apparatus. (Technically Class E doesn t exists however this is used for convenience here) Class F - fires involving cooking oils such as in deep-fat fryers. IV. CAUSES OF FIRE The biggest causes of vehicle fires are fuel (gasoline) related. Types of extinguishers Fuel Related Car Fires. Vehicle Fires due to Electrical Causes. Car Fires Related to the Exhaust System. Car Fires Caused by Petroleum Based Fluids. Fig. 1 types of extinguisher Water extinguishers Water extinguishers are one of the most costeffective ways to fight Class A fires, those fuelled by solid materials such as paper, wood and textiles. There are four different types of water extinguishers: water jet, water spray, water with additives and water mist or fog. Water jet extinguishers work by spraying a jet of water at the burning materials, cooling them and preventing reignition. They should not be used on live electrical equipment. Water extinguishers with additives are water extinguishers with foaming chemicals added. The water loses its natural surface tension meaning that it can soak into the burning materials more effectively. Adding the chemicals to the water means that a smaller extinguisher can produce the same fire rating as a larger, water only, extinguisher. All water extinguishers have a red label. Foam extinguishers Foam fire extinguishers can be used on Class A and B fires. They are most suited to extinguishing liquid fires such as petrol or diesel and are more versatile than water jet extinguishers because they can also be used on solids such as wood and paper. The foam extinguishes liquid fires by sealing the surface of the liquid, preventing flammable vapors reaching the air and starving the fire of fuel. They are not suitable for use on free flowing liquid fires. Foam extinguishers have a cream label. Powder extinguishers Powder extinguishers are a good multi-purpose fire extinguisher because they can be used on Class A, B and C fires. They can also be used on fires involving electrical equipment however; they do not cool the fire so it can re-ignite. Powder extinguishers can also create a loss of visibility and may create breathing problems. They are not generally recommended for use inside buildings unless there is absolutely no alternative. Powder extinguishers have a blue label. Carbon dioxide extinguishers (CO₂) CO₂ extinguishers are ideal for places with a lot of electrical equipment such as offices or server rooms because they are safe to use on fires involving electrical apparatus. Carbon dioxide extinguishers do not leave any residue, unlike a foam extinguisher. They can also be used on Class B fires, those involving flammable liquids such paraffin or petrol. CO₂ extinguishers work by smothering the fire and cutting off the supply of air. Carbon Dioxide Extinguishers (CO₂) have a black label.

3 Wet chemical extinguishers Wet chemical extinguishers are suitable for use on Class F fires involving cooking oils and fats, such as lard, olive oil, sunflower oil, maize oil and butter. They are extremely effective, when used correctly. The wet chemical rapidly knocks the flames out, cools the burning oil and chemically reacts to form a soap-like solution, sealing the surface and preventing re-ignition and they are primarily designed for use on Class F fires, cooking oils and deep fat fryers. They can also be used on Class A fires (wood, paper and fabrics) and Class B fires (flammable liquids). Wet chemical extinguishers have a yellow label. Fire blankets Fire blankets are primarily for use on hot oil fires such as frying pans or small deep fat fryers. They can also be used on someone whose clothing has caught fire. They work by smothering the fire, stopping access to the oxygen fuelling it and extinguishing it. V. HARDWARE REQUIRED 5.1.Flame sensor There are multiple sources that can detect fire in a vehicle like Ionization detectors it work on the principle that burning materials release many different products of combustion. Sense the presence of invisible charged particles (ions) Small amount of radioactive material. Smoke particles enters the chamber, they neutralize the charged particles and interrupts the current flow. This interruption activates the alarm it is more common & less expensive. React more quickly to fast burning fires. Fumes, dust and steam trigger unwanted alarms. Photoelectric smoke detectors it use a light beam & a photo cell to detect larger visible particles of smoke. Operate by reflecting a light beam, into or away from the photocell, depending on the design. When visible particles reflect in or away from the photocell, the alarm is activated. More responsive to slow-burning or smoldering the fires. Less prone to fumes, dust and steam unwanted alarms. Both types are acceptable life-safety devices. Combination ionization/ photoelectric smoke alarms look very similar to each other. Only way to identify correct type is to read the label on the back of the case. But these devises are not that fast active or that much accurate. As fire can spread to the entire vehicle in nothing more than two minutes or it cannot be approachable in less than one minute it becomes unavoidable that we need a much more modern and effective system that can detect fire in beginning stage. So we use flame detection sensor, Flame Detection Sensor Module is sensitive to the flame, but also can detect ordinary light. Usually used as a flame alarm. Detect a flame or a light source of a wavelength in the range of 760nm-1100 nm. Detection points of about 60 degree, particularly sensitive the flame spectrum. Sensitivity is adjustable, stable performance. So we can detect fire in starting stage. Fig. 2 flame sensor 5.2 Solenoid valve A solenoid valve is an electromechanically operated valve. The valve is controlled by an electric current through a solenoid: in the case of a two-port valve the flow is switched on or off; in the case of a three-port valve, the outflow is switched between the two outlet ports. Multiple solenoid valves can be placed together on a manifold. Solenoid valves are the most frequently used control elements in fluidics. Their tasks are to shut

4 off, release, dose, distribute or mix fluids. They are found in many application areas. Solenoids offer fast and safe switching, high reliability, long service life, good medium compatibility of the materials used, low control power and compact design. Besides the plunger-type actuator which is used most frequently, pivoted-armature actuators and rocker actuators are also used. Fig. 4 solenoid valve While there are multiple design variants, the following is a detailed breakdown of a typical solenoid valve design. A solenoid valve has two main parts: the solenoid and the valve. The solenoid converts electrical energy into mechanical energy which, in turn, opens or closes the valve mechanically. A direct acting valve has only a small flow circuit, shown within section E of this diagram (this section is mentioned below as a pilot valve). In this example, a diaphragm piloted valve multiplies this small pilot flow, by using it to control the flow through a much larger orifice. Solenoid valves may use metal seals or rubber seals, and may also have electrical interfaces to allow for easy control. A spring may be used to hold the valve opened (normally open) or closed (normally closed) while the valve is not activated. The diagram to the right shows the design of a basic valve, controlling the flow of water in this example. At the top figure is the valve in its closed state. The water under pressure enters at A. B is an elastic diaphragm and above it is a weak spring pushing it down. The diaphragm has a pinhole through its center which allows a very small amount of water to flow through it. This water fills the cavity C on the other side of the diaphragm so that pressure is equal on both sides of the diaphragm; however the compressed spring supplies a net downward force. The spring is weak and is only able to close the inlet because water pressure is equalized on both sides of the diaphragm. Fig. 3 function of solenoid valve A- Input side B- Diaphragm C- Pressure chamber D- Pressure relief passage E- Electro Mechanical Solenoid F- Output side Once the diaphragm closes the valve, the pressure on the outlet side of its bottom is reduced, and the greater pressure above holds it even more firmly closed. Thus, the spring is irrelevant to holding the valve closed. The above all works because the small drain passage D was blocked by a pin which is the armature of the solenoid E and which is pushed down by a spring. If current is passed through the

5 solenoid, the pin is withdrawn via magnetic force, and the water in chamber C drains out the passage D faster than the pinhole can refill it. The pressure in chamber C drops and the incoming pressure lift the diaphragm, thus opening the main valve. Water now flows directly from A to F. When the solenoid is again deactivated and the passage D is closed again, the spring needs very little force to push the diaphragm down again and the main valve closes. In practice there is often no separate spring; the elastomer diaphragm is molded so that it functions as its own spring, preferring to be in the closed shape. From this explanation it can be seen that this type of valve relies on a differential of pressure between input and output as the pressure at the input must always be greater than the pressure at the output for it to work. The pressure at the output, for any reason, rise above that of the input then the valve would open regardless of the state of the solenoid and pilot valve. Solenoid valve is activated by relay circuit with flame sensor. It generates power to valve to extinguish fire. Flame sensor detect fire and send information to relay that supply power to valve so extinguisher is activate to suppress fire in vehicle. In our application, the liquid is essentially incompressible and of low viscosity, and only The following factors need be considered in sizing a valve CV = Flow factor of valve Q = Flow expressed in U.S. gallon per minute (GPM) P = Pressure drop across the valve (= P1-P2) P1 = Inlet Pressure (psig) P2 = Outlet Pressure (psig) G = Specific Gravity of the fluid (G = 1.0 for water at 16 C (60 F)) These factors are related according to the equation 5.3 Relay module The relay module is a separate hardware device used for remote device switching. With it you can remotely control devices over a network or the Internet. Devices can be remotely powered on or off. You can control computers, peripherals or other powered devices from across the office or across the world. The Relay module can be used to sense external On/Off conditions and to control a variety of external devices. The PC interface connection is made through the serial port. The Relay module houses two SPDT relays and one wide voltage range, optically isolated input. These are brought out to screw-type terminal blocks for easy field wiring. Individual LED s on the front panel monitor the input and two relay lines. The module is powered with an AC adapter. Relays are switches that open and close circuits electromechanically or electronically. Relays control one electrical circuit by opening and closing contacts in another circuit. As relay diagrams show, when a relay contact is normally open (NO), there is an open contact when the relay is not energized. When a relay contact is Normally Closed (NC), there is a closed contact when the relay is not energized. In either case, applying electrical current to the contacts will change their state. Relays are generally used to switch smaller currents in a control circuit and do not usually control power consuming devices except for small motors and Solenoids that draw low amps. Nonetheless, relays can "control" larger voltages and amperes by having an amplifying effect because a small voltage applied to a relays coil can result in a large voltage being switched by the contacts. Fig. 5 relay module

6 Protective relays can prevent equipment damage by detecting electrical abnormalities, including overcurrent, undercurrent, overloads and reverse currents. In addition, relays are also widely used to switch starting coils, heating elements, pilot lights and audible alarms. Electromechanical Relays Basic parts and functions of electromechanical relays include: Frame: Heavy-duty frame that contains and supports the parts of the relay. Coil: Wire is wound around a metal core. The coil of wire causes an electromagnetic field. Armature: A relays moving part. The armature opens and closes the contacts. An attached spring returns the armature to its original position. Contacts: The conducting part of the switch that makes (closes) or breaks (opens) a circuit. Break: This is the number of separate places or contacts that a switch uses to open or close a single electrical circuit. All contacts are either single break or double break. A single break (SB) contact breaks an electrical circuit in one place, while a double break (DB) contact breaks it in two places. Single break contacts are normally used when switching lower power devices such as indicating lights. Double break contacts are used when switching high-power devices such as solenoids. Pole: This is the number of completely isolated circuits that relays can pass through a switch. A single-pole contact (SP) can carry current through only one circuit at a time. A double-pole contact (DP) can carry current through two isolated circuits simultaneously. The maximum number of poles is 12, depending upon a relays design. Throw: This is the number of closed contact positions per pole that are available on a switch. A switch with a single throw contact can control only one circuit, while a double-throw contact can control two. 5.4 Buzzer A buzzer or beeper is an audio signaling device, which may be mechanical, electromechanical, or piezoelectric (piezo for short). Typical uses of buzzers and beepers include alarm devices, timers, and confirmation of user input such as a mouse click or keystroke. Electromechanical Early devices were based on an electromechanical system identical to an electric bell without the metal gong. Similarly, a relay may be connected to interrupt its own actuating current, causing the contacts to buzz. Often these units were anchored to a wall or ceiling to use it as a sounding board. The word "buzzer" comes from the rasping noise that electromechanical buzzers made. 5.5.Solenoid control circuit Fig. 6 control circuit Working As per the circuit diagram sensor, relay module, buzzer and batteries are connected. Solenoid valve is connected in co₂ extinguisher then the pipe is connected to solenoid valve. When fire or flame occurs sensor sense that and transmit that signal to relay module, relay switched the way path (NC to NO) of current so it activate the solenoid valve then the gas co₂ is released from extinguisher to suppression the fire. This whole process is done within 3 second so it is very useful for fire suppression in vehicle it can save passenger from injuries and dead. VI. ASSESSMENT The firefighting system can detect fire in 2 meter, so it has to be used in a vehicle to detect the position of the fire. So a single unit with four sensors is enough to cover a whole vehicle. It is

7 enough for a car to be protected. This system can be used not only for vehicle but also for industrial domestic and commercial purpose. Structures like large heavy vehicle would require more than one unit. Normally the standard length of a car is average 4 meters. So for a 4 meters length vehicle we have calculated that we need 1 firefighting system with four flame sensors and CO₂ extinguisher. The amount of the system is low in compare to other fire extinguisher. 6.1 Cost The cost of our project is more than a normal extinguisher. By a survey it is proved that by using fire extinguisher the safety of the people are increasing but at the same time the price of the fire extinguisher are also increased at the same rate. In compare to that fire suppression system our automatic fire extinguisher system is not costlier. So it is more profitable than any other fire extinguisher. 6.2 Safety: The firefighting system is automated. So it can works automatically, no one has to operate the system or use it at risky position when fire hazard occurs. So it is too much safe in compare with other fire extinguisher. We know that firefighting is a very risky occupation. Many people are becoming injured by using fire extinguisher, but automated firefighting system can ensure us a safe environment without destroying anyone s life VII. CONCLUSION In our daily life, whether it s a vehicle or domestic, the most common and fatal accidents occurred are due to fire. This results in both human loss and property loss. Fires claim the lives of innocent people around the world every single day. A small amount of fire is able to damage a huge part of a society. Although smoke detectors and fire alarms alert people of danger, they often have few choices other than escaping from a building and calling the fire department. Although waiting for fire fighters to rescue people may not always be the best choice. The modern day home and business should be equipped with at least one fire extinguisher. Using modern fire extinguisher is not so easy and only a professional user can use it. Firefighting is a highly technical profession which needs a lot of training and education to become a professional. So using a fire extinguisher is not at all suitable for people s residence. For those purpose automated firefighting system will be the best choice. In this study, a system that automatically extinguishing fires in commercial automobiles was proposed. The structure and the operational method of the automatic extinguishing system were proposed considering the characteristics of commercial vehicles. Lab scale simulation of the proposed method was employed to determine its performance: the following conclusions were obtained. However, the performance of the automatic extinguishing system proposed in this study was assessed only in lab environment. Thus, research on product testing and a mass production design process for commercialization is necessary. Furthermore, study on fire extinguishing medium or extinguishing method that does not affect the engine parts is necessary in order to resolve the issue of completely replacing automobile engine par VIII. REFERANCE [1] Anis Ahmed & Ruma Paul "More than 100 die in garment factory fire, the deadliest in Bangladesh's history". The Christian Science Monitor. Archived from the original on 25 November 2012.Retrived 3 may 2013 [2] A. Bardshaw, The UK security and firefighting advanced robot project, in IEE Coll. on Advanced Robotic Initiatives in the UK, London,UK, [3] Shafkat Hossain (9 April 2014). Fire detection two Source [4] Solenoid valve for processing applications,

Intelligent monitoring system for automobiles

Intelligent monitoring system for automobiles RESEARCH ARTICLE OPEN ACCESS Intelligent monitoring system for automobiles M.PADMA LALITHA 1, M.MUNI KUMAR 2, K.NAGENDRA BABU 3, K.RAVI TEJA 4 Dept. of Electrical and Electronics Engineering, Annamacharya

More information

Employers Responsibilities

Employers Responsibilities Why? Fire Kills! Each year 700 people die as a result of fires in their own homes A further 14000 are injured The best way to avoid danger is to prevent fire starting in the first place Legislation Fire

More information

Fire Safety. Version 1.0

Fire Safety. Version 1.0 This document is intended to provide basic safety guidelines for the Physical Plant Department at Community College of Allegheny County. The information provided in this guide may vary by site. Version

More information

Fin-Fan Control System

Fin-Fan Control System IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 02, 2014 ISSN (online): 2321-0613 Fin-Fan Control System Pankaj Shah 1 Jignesh Vaghela 2 1, 2 Student 1, 2 Instrumentation

More information

II. METHODS AND MATERIALS

II. METHODS AND MATERIALS Smart Home using PLC Naveen Kumar P 1, Naveen Kumar K 2, Arvind M 3, Senthilraja S 4 1,2,3 U.G. Student, 4 Assistant Professor Department of Mechanical and Automation Engineering, Mahendra Engineering

More information

Detection, and Suppression Systems

Detection, and Suppression Systems Fire Detection, Protection, ti and Suppression Systems Objectives (1 of 5) Explain why all fire fighters should have a basic understanding of fire protection systems. Describe the basic components and

More information

INSTRUCTOR GUIDE COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 1 TOPIC: ORIENTATION AND FIRE BEHAVIOR LEVEL OF INSTRUCTION:

INSTRUCTOR GUIDE COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 1 TOPIC: ORIENTATION AND FIRE BEHAVIOR LEVEL OF INSTRUCTION: COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 1 INSTRUCTOR GUIDE TOPIC: ORIENTATION AND FIRE BEHAVIOR LEVEL OF INSTRUCTION: TIME REQUIRED: THREE HOURS MATERIALS: APPROPRIATE AUDIO VISUAL AIDS REFERENCES:

More information

Leader s Guide 2007 CLMI Training

Leader s Guide 2007 CLMI Training C3585 FIRE EXINGUISHERS: Ready To Respond Leader s Guide 2007 CLMI Training FIRE EXTINGUISHERS:Ready To Respond This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation.

More information

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE Worldwide Safety Services Fire Extinguisher Training D 1 Objectives Understand the combustion process and different fire classes. Understand d fire extinguisher i types, operating procedures, capabilities,

More information

Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015

Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015 Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015 Fire Protection I. INTRODUCTION II. GENERAL GUIDELINES III.

More information

E4218 Fire Extinguisher Basic Training. Leader s Guide

E4218 Fire Extinguisher Basic Training. Leader s Guide E4218 Fire Extinguisher Basic Training Leader s Guide FIRE EXTINGUISHER BASIC TRAINING This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation. Featured are: INTRODUCTION

More information

Cadet Entry Level Award(ELA) Part Four. Fire Safety

Cadet Entry Level Award(ELA) Part Four. Fire Safety Cadet Entry Level Award(ELA) Part Four Fire Safety By the end of this ELA module you will Have an understanding of Fire Be able to reduce Fire risk at Work Know what to do when the Fire Alarm sounds Know

More information

TIMOTHY R. SZYMANSKI Instructor

TIMOTHY R. SZYMANSKI Instructor Fire & Life Safety TIMOTHY R. SZYMANSKI Instructor 44 years experience as a firefighter serving in every position from firefighter/paramedic to fire chief. Nationally and State Certified Fire & Life Safety

More information

Microcontroller based design for Tele-sensing and extinguishing fire

Microcontroller based design for Tele-sensing and extinguishing fire Microcontroller based design for Tele-sensing and extinguishing fire Hany abdelhady Almedhegi 1, Ameen babekr abdelnaby 2, Abdelrasoul Jabar Alzubaidi 3 1 Sudan Academy of Sciences (SAS); Council of Engineering

More information

Safety Manual Section 7 Fire/Life Safety

Safety Manual Section 7 Fire/Life Safety 7. FIRE/LIFE SAFETY The following sections provide fire/life safety guidelines and procedures. This section covers the following topics: Topic Page 7.1 General... 7-2 A. The Effects of a Fire... 7-2 B.

More information

FIRE SAFETY. This easy-to-use Leaders Guide is provided to assist in conducting a successful presentation. Featured are:

FIRE SAFETY. This easy-to-use Leaders Guide is provided to assist in conducting a successful presentation. Featured are: FIRE SAFETY This easy-to-use Leaders Guide is provided to assist in conducting a successful presentation. Featured are: INTRODUCTION: A brief description of the program and the subject that it addresses.

More information

Basic Fire Safety Awareness Training.

Basic Fire Safety Awareness Training. Basic Fire Safety Awareness Training Training Syllabus Session 1 Causes of fire in the workplace Session 2 Classes of fire and types of fire extinguisher Session 3 Practical fire extinguisher training

More information

2. How to trace out fault in an electrical circuit? Step 1 - Power Down

2. How to trace out fault in an electrical circuit? Step 1 - Power Down 1. What is the difference between series and parallel circuit? In a series circuit, the current through each of the components is the same, and the voltage across the circuit is the sum of the voltages

More information

Evaporation The process in which a liquid dissipates or emits vapor, fumes, or invisible minute particles.

Evaporation The process in which a liquid dissipates or emits vapor, fumes, or invisible minute particles. 35 Evaporation of waste wash water occurs during normal operation of the pressure, steam or automatic vehicle wash system. It is generally assumed that 10-30% of wash water is lost to evaporation. Accelerated

More information

FIRE AND FIRE FITTING By Mr. Prashant Sansare

FIRE AND FIRE FITTING By Mr. Prashant Sansare FIRE AND FIRE FITTING By Mr. Prashant Sansare What is mean by fire? CASE STUDY What Happened? Late one evening, a large storage tank containing a flammable liquid began to overflow. It was not detected

More information

Fire Safety. Presenter, Kevin V Coleman September 14 th 2016

Fire Safety. Presenter, Kevin V Coleman September 14 th 2016 Fire Safety Presenter, Kevin V Coleman September 14 th 2016 Fire is a significant risk WHAT IS FIRE? To start or continue to burn, a fire requires: Heat; Fuel (Combustible materials); Oxygen. This is known

More information

A comprehensive systems-level approach in cabin design minimizes fire potential and helps ensure passenger safety. aero quarterly qtr_04 11

A comprehensive systems-level approach in cabin design minimizes fire potential and helps ensure passenger safety. aero quarterly qtr_04 11 A comprehensive systems-level approach in cabin design minimizes fire potential and helps ensure passenger safety. 18 aero quarterly qtr_04 11 Fire Protection: Passenger cabin the cabins on all boeing

More information

Portable Fire Extinguishers

Portable Fire Extinguishers Portable Fire Extinguishers Workbook Activities The following activities have been designed to help you. Your instructor may require you to complete some or all of these activities as a regular part of

More information

Fire Safety Handbook

Fire Safety Handbook Fire Safety Handbook For Faculty, Staff, and Teaching Assistants Public Safety Emergency Numbers: Washington Square 212-998-2222 Dental Center 212-998-9828 IFA 212-772-5808 School of Engineering 718-260-3537

More information

Consumer Product Safety Commission Smoke Alarms Why, Where, and Which CPSC Document #559

Consumer Product Safety Commission Smoke Alarms Why, Where, and Which CPSC Document #559 Consumer Product Safety Commission Smoke Alarms Why, Where, and Which CPSC Document #559 A smoke alarm is critical for the early detection of a fire in your home and could mean the difference between life

More information

LPG GAS LEAKAGE DETECTION, MONITORING AND CONTROL USING LabVIEW

LPG GAS LEAKAGE DETECTION, MONITORING AND CONTROL USING LabVIEW LPG GAS LEAKAGE DETECTION, MONITORING AND CONTROL USING LabVIEW M.J.Kesavan 1, R.Rajesh Kannan 2,S.Vijay vishwanath 3, P.Sathya 4. UG Students, Instrumentation & control engg, Asst. professor, Instrumentation

More information

Android Controlled Fire Fighting Robot

Android Controlled Fire Fighting Robot IJSTE - International Journal of Science Technology & Engineering Volume 3 Issue 09 March 2017 ISSN (online): 2349-784X Android Controlled Fire Fighting Robot S. Sakthi Priyanka R. Sangeetha Department

More information

WELCOME TO ROSEVILLE UNIVERSITY

WELCOME TO ROSEVILLE UNIVERSITY WELCOME TO ROSEVILLE UNIVERSITY HOME FIRE PREVENTION Welcome All about home fires Smoke alarms & CO alarms Home escape plan Fire safety at home Where do Home Fires Start? According to NFPA, 42% of the

More information

Chapter 7 Fire Protection

Chapter 7 Fire Protection Chapter 7 Fire Protection 7.1 Risk and Fire Protection Planning 140 7.2 Fire Detection System 142 7.3 Fire Alarm Center and Systems Engineering 143 7.4 Alarm and Evacuation 144 7.5 Fire Extinguishing Systems

More information

Element C3.4 Fire Fighting Equipment

Element C3.4 Fire Fighting Equipment .4 Fire Fighting Equipment Classification of Fires Class A Solids. Wood, paper, plastics Class B Liquids Petrol oil, paint Class C Gases LPG, natural gas Classification of Fires Class D Metals Zinc, sodium,

More information

KRISHNAMURTI FOUNDATION TRUST FIRE SAFETY POLICY. Last Review Date 30 June Next review date 30 August Health and Safety Officer

KRISHNAMURTI FOUNDATION TRUST FIRE SAFETY POLICY. Last Review Date 30 June Next review date 30 August Health and Safety Officer KRISHNAMURTI FOUNDATION TRUST FIRE SAFETY POLICY Last Review Date 30 June 2015 Policy endorsed by Policy is maintained by ISI reference Trustees Co-Principals/Directors A9, B6, B9 Next review date 30 August

More information

Guide to choosing the right portable Fire Extinguisher. Produced in association with the UK Fire Association

Guide to choosing the right portable Fire Extinguisher. Produced in association with the UK Fire Association Guide to choosing the right portable Fire Extinguisher Produced in association with the UK Fire Association How to choose the right portable Fire Extinguisher It is vitally important to select extinguishers

More information

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

S12 Fire Safety Risk Assessment H&SFS01-1 / 9 S12 Fire Safety Risk Assessment H&SFS01 Risk ratings The following risk ratings are based on two factors: The overall fire risk rating for the site The risk rating for the individual recommendations /control

More information

InstrumentationTools.com

InstrumentationTools.com Author: Instrumentation Tools Categories: Fire & Gas System Overview of Fire/Smoke/Flame/Heat/Gas Detectors Fire Detectors Fire detectors are available for residential, commercial, and industrial use.

More information

These are just basic training slides, may vary from standards. Fire Safety. 1

These are just basic training slides, may vary from standards. Fire Safety.   1 These are just basic training slides, may vary from standards Fire Safety www.askmaaz.com 1 Most common causes of fire faulty or misused electrical equipment a build-up of rubbish or waste material (poor

More information

Cooker Hood LA-72-CAN.

Cooker Hood LA-72-CAN. Cooker Hood LA-72-CAN EN www.luxairhoods.com WARNINGS Safety This equipment can be used by children aged 8 or more, people with physical, mental and sensory disabilities or inexperienced users it they

More information

Design and Development of Industrial Pollution Monitoring System using LabVIEW and GSM

Design and Development of Industrial Pollution Monitoring System using LabVIEW and GSM Design and Development of Industrial Pollution Monitoring System using LabVIEW and GSM Dr. Channappa Bhyri¹, Eliyaz Ahmed² 2 Student, Dept. of Electronics and Instrumentation, PDACE, Kalaburgi, Karnataka,

More information

Portable Generator Safety Lloyd Shank, P.E. Director of Electric and Gas Utilities 4/12/2005

Portable Generator Safety Lloyd Shank, P.E. Director of Electric and Gas Utilities 4/12/2005 Portable Generator Safety Lloyd Shank, P.E. Director of Electric and Gas Utilities 4/12/2005 Page 1 of 10 Portable Generator Safety During the process of restoring electric power to a neighborhood Line

More information

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. 2 MistMax Low pressure WaterMist fire suppression skid Our modular fire skid is customised to suit your specific

More information

"USING FIRE EXTINGUISHERS"

USING FIRE EXTINGUISHERS PRESENTER'S GUIDE "USING FIRE EXTINGUISHERS" Part of the "SAFETY MEETING KIT" Series Quality Safety and Health Products, for Today...and Tomorrow OUTLINE OF MAJOR PROGRAM POINTS The following outline summarizes

More information

LEARNING SPECIAL HAZARD DETECTION TYPES

LEARNING SPECIAL HAZARD DETECTION TYPES LEARNING SPECIAL HAZARD DETECTION TYPES JUNE 2013 COPYRIGHT CLIMATEC SPECIAL HAZARDS DETECTION TYPES EXPLAINED STAGE ONE DETECTION - ACTIVE AIR SAMPLING\\INCIPIENT AND IN- VISIBLE SMOKE STAGE AIR SAMPLING

More information

guide to fire safety

guide to fire safety guide to fire safety Fire safety should be a vital issue for everyone living in rented accommodation, yet some tenants still tamper with fire safety equipment and risk their lives. If you are living in

More information

WHEN a fire starts, the first few seconds are critical. Thus, fire

WHEN a fire starts, the first few seconds are critical. Thus, fire Extinguishing Fires in Agricultural Mechanics WHEN a fire starts, the first few seconds are critical. Thus, fire extinguishers must be easily accessible. Knowledge of how to use a fire extinguisher correctly

More information

Emergency Action and Fire Prevention

Emergency Action and Fire Prevention Emergency Action and Fire Prevention History Triangle Shirtwaist Factory Fire New York City: March 25, 1911 8 th, 9 th and 10 th floor of Asch building Shirtwaists (women s blouses) Fire broke out at 4:40

More information

Using Fire Extinguishers. Leaders Guide and Quiz

Using Fire Extinguishers. Leaders Guide and Quiz ! Using Fire Extinguishers Leaders Guide and Quiz 3578 INTRODUCTION TO THE PROGRAM Structure and Organization Information in this program is presented in a definite order so that employees will see the

More information

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES CHAPTER 18 SECTION 1801 GENERAL 1801.1 Scope. Semiconductor fabrication facilities and comparable research and development areas classified as Group H-5 shall comply with this chapter and the International

More information

EXTINGUISHING SYSTEM DETECTION AND CONTROL

EXTINGUISHING SYSTEM DETECTION AND CONTROL GAP.13.0.1 A Publication of Global Asset Protection Services LLC EXTINGUISHING SYSTEM DETECTION AND CONTROL INTRODUCTION Extinguishing systems require prompt detection systems so they operate quickly and

More information

Special solution KS marine. Kitchen protection system KS marine Fire prevention for galleys

Special solution KS marine. Kitchen protection system KS marine Fire prevention for galleys Special solution KS 2000-8 marine Kitchen protection system KS 2000-8 marine Fire prevention for galleys RiskDeep fat fryer fire Safety requirements for passengers and crew are especially high at sea.

More information

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971 INDEPENDENT FIRE EXTINGUISHER SALES & Your First Line of Defense Since 97 Suppression Sales i Installation i Service ABOUT IFESSAR In business since 97 Serve over 4000 customers Service Arkansas and Mississippi

More information

Safe Fire Extinguisher Use

Safe Fire Extinguisher Use Safe Fire Extinguisher Use Otis College of Art and Design Health and Safety Training Series Peter Zaretskiy Environmental Health & Safety Manager pzaretskiy@otis.edu Fire Extinguishers Basic Information

More information

Three elements of fire. Heat Oxygen Fuel. Remove one of the three and the fire is extinguished.

Three elements of fire. Heat Oxygen Fuel. Remove one of the three and the fire is extinguished. ABC s Three elements of fire Heat Oxygen Fuel Remove one of the three and the fire is extinguished. Fires are classified based on type of fuel. Extinguishers are also classified on the type of fire they

More information

Fire is No Accident Fire is No Accident It can be prevented.

Fire is No Accident Fire is No Accident It can be prevented. 1 Fire is No Accident It can be prevented. 2 3 States of Matter Solid Liquid Gas 3 What is Fire? Answer: Fire is a phenomena that occurs when a substance combines with fuel and has adequate oxygen. Typically

More information

Fire Prevention. Risk Management Services. October 7-13, 2012 National Fire Prevention Week National Fire Protection Association

Fire Prevention. Risk Management Services. October 7-13, 2012 National Fire Prevention Week National Fire Protection Association Fire Prevention October 7-13, 2012 National Fire Prevention Week National Fire Protection Association Have TWO Ways Out! 2012 NFPA Fire Prevention Week Theme Make an Emergency Plan & Practice it! Almost

More information

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6 BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6 1. Purpose This policy sets forth requirements for preventing and detecting fires, sounding an alarm, and suppressing fires. Fire protection

More information

Essentials of Fire Fighting 6 th Edition Firefighter I

Essentials of Fire Fighting 6 th Edition Firefighter I 1 Essentials of Fire Fighting 6 th Edition Firefighter I Chapter 5 Fire Behavior Replace with manual graphic on slide master Learning Objective 1 2 Explain the science of fire as it relates to energy,

More information

SECURITY BLANKET Foam Fire Protection Products

SECURITY BLANKET Foam Fire Protection Products SECURITY BLANKET Foam Fire Protection Products REAL DANGERS DEMAND REAL SOLUTIONS If your business manufactures, stores, or transports flammable liquids, the thought of a devastating fire always burns

More information

Design & Control of an Elevator Control System using PLC

Design & Control of an Elevator Control System using PLC Design & Control of an Elevator Control System using PLC Prof. Omkar M. Shete 1, Ms. Amrita A. Vitekar 2, Ms. Ashwini N. Patil 3 Assistant Professor, Electrical Engineering Department, NBN Sinhgad School

More information

Sprinklers Modeling for Tunnel Road Fire Fighting

Sprinklers Modeling for Tunnel Road Fire Fighting Sprinklers Modeling for Tunnel Road Fire Fighting P. Ciambelli, M.G. Meo, P. Russo, S. Vaccaro Department of Chemical and Food Engineering, University of Salerno - ITALY 1. INTRODUCTION Loss of lives and

More information

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES CHAPTER 18 SEMICONDUCTOR FABRICATION FACILITIES SECTION 1801 GENERAL 1801.1 Scope. Semiconductor fabrication facilities and comparable research and development areas classified as Group H-5 shall comply

More information

Carbon Monoxide Alarms Smoke and Carbon Alarms Upgrade Requirements for Single and Two Family Dwellings

Carbon Monoxide Alarms Smoke and Carbon Alarms Upgrade Requirements for Single and Two Family Dwellings Planning and Building Department INFORMATIONAL GUIDE Updated: 2017 July 31 Smoke Alarms This brochure explains the requirements for smoke alarms in new or renovated buildings. It provides information to

More information

User Guide. * Depending on model. EN 1. TE_FRYERS_FILTRA-ONE_UK_NC _Mise en page 1 06/12/13 15:36 PageC1.

User Guide. * Depending on model. EN 1. TE_FRYERS_FILTRA-ONE_UK_NC _Mise en page 1 06/12/13 15:36 PageC1. TE_FRYERS_FILTRA-ONE_UK_NC00122287_Mise en page 1 06/12/13 15:36 PageC1 EN 1 2 3 4 5 6 7 8 9 Réf. NC00122287 12/2013 ESPACE GRAPHIQUE User Guide www.tefal.com 12 13 * Depending on model. 10 11 TE_FRYERS_FILTRA-ONE_UK_NC00122287_Mise

More information

DOMESTIC SMOKE ALARMS AND SPRINKLERS. Introduction. Materials and methods. Frank SWANN 1. Legislative impact. Review article

DOMESTIC SMOKE ALARMS AND SPRINKLERS. Introduction. Materials and methods. Frank SWANN 1. Legislative impact. Review article DOMESTIC SMOKE ALARMS AND SPRINKLERS Frank SWANN 1 Abstract: Key words: Making further inroads into the reduction of fire deaths and injuries in the home is a clear ambition of the UK Chief Fire Officers

More information

Fire Prevention Plan Program

Fire Prevention Plan Program Fire Prevention Plan Program Effective Date: Revision #: Reference Standard Purpose Occupational Safety and Health Administration (OSHA) standard, 29 CFR 1910.39 Subpart E, Fire Prevention Plan This procedure

More information

Fire Detection and Fire Fighting Testing and Approval on Railway Vehicles

Fire Detection and Fire Fighting Testing and Approval on Railway Vehicles Fire Detection and Fire Fighting Testing and Approval on Railway Vehicles Peter Stahl Wagner Schweiz AG, Wallisellen, Switzerland Abstract Fire detection system and firefighting solutions are getting a

More information

SUPPRESSION SALES I INSTALLATION I SERVICE

SUPPRESSION SALES I INSTALLATION I SERVICE SUPPRESSION SALES I INSTALLATION I SERVICE ABOUT FESSAR In business since 1973 Serve over 4000 customers Service Arkansas and Mississippi Trained and certified suppression technicians Technicians are Arkansas

More information

Frequently Asked Smoke Alarm Questions

Frequently Asked Smoke Alarm Questions Frequently Asked Smoke Alarm Questions Why should my home have smoke alarms? Most fire deaths are caused by smoke not flames. Most fire deaths and injuries occur between midnight and 8 a.m. when people

More information

Fire Safety Awareness Workbook

Fire Safety Awareness Workbook Fire Safety Awareness Workbook For All Staff Please ensure you read the workbook thoroughly and complete the assessment at the end Version 2. Introduction Fire safety training is a mandatory element of

More information

Fire extinguishers. Amicus guide

Fire extinguishers. Amicus guide Fire extinguishers Amicus Hayes Court, West Common Road, Hayes, Bromley, Kent BR2 7AU Tel: 020 8462 7755 Fax: 020 8315 8234 Website: www.amicustheunion.org Amicus guide October 2005 Amicus guide to fire

More information

EN User Guide

EN User Guide EN User Guide www.tefal.com 1 2 3 4 5 6 7 11 9 8 10 * Depending on model. fig 1 fig 2 fig 3 fig 4 fig 5 fig 6 fig 7 fig 8 fig 9 1 min. 30 sec 0L fig 10 fig 11 fig 12 Click X1 Click fig 12a fig 13 fig 14

More information

So what is a fire hazard?

So what is a fire hazard? So what is a fire hazard? A situation where there is a greater than normal risk of a fire starting. For a fire to start there have to be three components: fuel, ignition and oxygen. If all three are present,

More information

Intelligent Fire Detection and Visual Guided Evacuation System Using Arduino and GSM

Intelligent Fire Detection and Visual Guided Evacuation System Using Arduino and GSM Intelligent Fire Detection and Visual Guided Evacuation System Using Arduino and GSM Naresh Kumar 1,Poonam Kumari 2 1 M.Tech(Instrumentation), UCIM, Panjab University, Chandigarh, India 2 Assistant Professor,

More information

Based on NFPA 1001: Standard for Fire Fighter Professional Qualifications, 2013 Edition.

Based on NFPA 1001: Standard for Fire Fighter Professional Qualifications, 2013 Edition. Based on NFPA 1001: Standard for Fire Fighter Professional Qualifications, 2013 Edition. Revised 02/10/2017 Alabama Fire College Firefighter II Instructional JPR Verification Sheet Full Name: Fire Department:

More information

Institute for Plasma Research Welcomes you all on

Institute for Plasma Research Welcomes you all on Institute for Plasma Research Welcomes you all on Presented By: D.V.MODI, Safety Officer, IPR Compiled by: SAFETY COMMITTEE, IPR WHAT IS FIRE? The self-sustaining process of rapid oxidation of a fuel,

More information

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas Intrinsic Safety Intrinsically Safe Solutions Accurate Weighing in Hazardous Areas Accidents in hazardous areas can have dramatic consequences for businesses in terms of both human life and profit. Intrinsically

More information

HEALTH AND SAFETY CONSIDERATIONS FOR THE MANAGEMENT OF BROWN GREASE

HEALTH AND SAFETY CONSIDERATIONS FOR THE MANAGEMENT OF BROWN GREASE HEALTH AND SAFETY CONSIDERATIONS FOR THE MANAGEMENT OF BROWN GREASE Presented by: Brian N. Polk Health & Safety Consultant II NC Division of Waste Management Presentation Topics Is your restaurant experiencing

More information

User Manual. 110 Cup (55 Cup Raw) Gas Rice Cooker. Model: 177GRCLP, 177GRCNAT 12/2018. Please read and keep these instructions. Indoor use only.

User Manual. 110 Cup (55 Cup Raw) Gas Rice Cooker. Model: 177GRCLP, 177GRCNAT 12/2018. Please read and keep these instructions. Indoor use only. 110 Cup (55 Cup Raw) Gas Rice Cooker Intertek 5010781 Conforms to ANSI STD Z83.11-2016 Model: 177GRCLP, 177GRCNAT 12/2018 FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids

More information

To understand FIRE and how to EXTINGUISH it, we first need to know: What is FIRE?

To understand FIRE and how to EXTINGUISH it, we first need to know: What is FIRE? To understand FIRE and how to EXTINGUISH it, we first need to know: What is FIRE? It is the rapid oxidation of a material, in the chemical process of combustion, releasing heat, light, and various reaction

More information

LP GAS LEKAGE ALARM. M. G.. D. D. Wickramasinghe 1*, N. Abhayasinghe 2

LP GAS LEKAGE ALARM. M. G.. D. D. Wickramasinghe 1*, N. Abhayasinghe 2 - 32 - LP GAS LEKAGE ALARM M. G.. D. D. Wickramasinghe 1*, N. Abhayasinghe 2 1* Corresponding Author, Department of Electronic and Computer Engineering, Sri Lanka Institute of Information Technology (SLIIT),

More information

TEXAS A&M UNIVERSITY EMERGENCY MANAGEMENT. Home Safety. Smoke Alarms

TEXAS A&M UNIVERSITY EMERGENCY MANAGEMENT. Home Safety. Smoke Alarms Smoke Alarms If you have a fire, smoke alarms can cut nearly in half your risk of dying in a fire. Smoke alarms sense abnormal amounts of smoke or invisible combustion gases in the air. They can detect

More information

USER S MANUAL LINCOLN PF Manufactured by: Planika Sp. z o.o. ul. Bydgoska Brzoza Poland

USER S MANUAL LINCOLN PF Manufactured by: Planika Sp. z o.o. ul. Bydgoska Brzoza Poland USER S MANUAL LINCOLN PF-0917-0075-000 Manufactured by: Planika Sp. z o.o. ul. Bydgoska 38 86-061 Brzoza Poland Edition i1266#00 as of 25.04.2017 Serial number greater than P5660 17 IT IS OBLIGATORY TO

More information

XBee Based Industrial And Home Security System

XBee Based Industrial And Home Security System XBee Based Industrial And Home Security System Introduction: Home security is one of the essential requirements for everyone nowadays due to the high rate of crimes. People are intended to take certain

More information

Please read this sheet as it contains important information

Please read this sheet as it contains important information Important Please read this sheet as it contains important information Before commencing installation please familiarise yourself to the equipment by reading the comprehensive installation instructions.

More information

Minifog PressProtect Fire protection solutions for industrial presses BRANCH SOLUTION

Minifog PressProtect Fire protection solutions for industrial presses BRANCH SOLUTION Minifog PressProtect ire protection solutions for industrial presses BRANCH SOLUTION RISKS detect During the production of OSB, PB, MD and HD boards with continuous or multi-opening presses, combustible

More information

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES CHAPTER 18 SEMICONDUCTOR FABRICATION FACILITIES SECTION 1801 GENERAL 1801.1 Scope. Semiconductor fabrication facilities and comparable research and development areas classified as Group H-5 shall comply

More information

FIRE TETRAHEDRON. Consists of 4 Sides. Oxygen. Fuel. Chain of reaction

FIRE TETRAHEDRON. Consists of 4 Sides. Oxygen. Fuel. Chain of reaction FIRE SAFETY FIRE TETRAHEDRON Triangle is out. Tetrahedron is in Consists of 4 Sides Oxygen Heat Fuel Chain of reaction WAYS TO EXTINGUISH FIRE By eliminating any one element from the fire Tetrahedron,

More information

FIRE SAFETY FOR OFFICE WORKERS

FIRE SAFETY FOR OFFICE WORKERS 2746 FIRE SAFETY FOR OFFICE WORKERS Leader s Guide ERI Safety Videos FIRE SAFETY FOR OFFICE WORKERS This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation. Featured

More information

Museum Towers EVACUATION PROCEDURE IN CASE OF FIRE

Museum Towers EVACUATION PROCEDURE IN CASE OF FIRE Museum Towers SP 40414 267-277 Castlereagh Street, Sydney, NSW 2000 Ph: 9267 1832 Fax: 9267 9485 Email: info@museumtowers.com.au Web: www.museumtowers.com.au EVACUATION PROCEDURE IN CASE OF FIRE Fire prevention

More information

OXYGEN. 21% in air. Does not burn - Supports combustion. Increased oxygen will intensify burning

OXYGEN. 21% in air. Does not burn - Supports combustion. Increased oxygen will intensify burning FIRE Rapid self-sustaining oxidation of a fuel and oxygen in the presence of heat usually with the production of heat, light, and combustion byproducts OXYGEN 21% in air Does not burn - Supports combustion

More information

THE FIRE SAFETY GUIDE FOR BUSINESS OWNERS

THE FIRE SAFETY GUIDE FOR BUSINESS OWNERS THE FIRE SAFETY GUIDE FOR BUSINESS OWNERS 0800 2211 8034 Table of Contents Part 1: Introduction Part 2: Who is Responsible? Part 3: What is Required? Fire Risk Assessments Appointment of Competent Persons

More information

Preventative Maintenance Tables

Preventative Maintenance Tables Preventative Maintenance Tables Table of Contents I. Table : Gas Fired Domestic Hot Water Heater II. III. IV. Table : Circulating Pump Table : Convectors Table 4: Grille and Diffusors V. Table 5: Unit

More information

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants Branch Solution Wood based panel plants Fire protection solutions for wood based panel plants afety throughout the production process R The versatility of wood as a raw material and the fact that it is

More information

Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE

Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE TERM highly protected risk (HPR) is commonly used in

More information

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified Thank you for purchasing our fully-automatic gas-fired tankless water heater. Please completely read this Manual

More information

FIRE SOLUTIONS >> FIRE EXTINGUISHERS DRY POWDER WATER CARBON DIOXIDE FOAM FEATURES

FIRE SOLUTIONS >> FIRE EXTINGUISHERS DRY POWDER WATER CARBON DIOXIDE FOAM FEATURES PRODUCT CATALOGUE FIRE SOLUTIONS >> FIRE EXTINGUISHERS There are basically four different types of fire extinguishers each of which extinguishes specific type of fire. Extinguishers use picture/labeling

More information

"FIRE PREVENTION AND SAFETY IN THE OFFICE"

FIRE PREVENTION AND SAFETY IN THE OFFICE MAJOR PROGRAM POINTS "FIRE PREVENTION AND SAFETY IN THE OFFICE" Part of the "GENERAL SAFETY SERIES" Quality Safety and Health Products, for Today...and Tomorrow Outline of Major Points Covered in the

More information

Directories. B.1 Keyword Directory B.2 Tables B.3 Figures B.4 End Notes Fire Safety Guide / Siemens Switzerland Ltd

Directories. B.1 Keyword Directory B.2 Tables B.3 Figures B.4 End Notes Fire Safety Guide / Siemens Switzerland Ltd B Directories B.1 Keyword Directory...326 B.2 Tables...329 B.3 Figures...330 B.4 End Notes...332 325 B.1 Keyword Directory A addressing (collective) 93, 125 addressing (individual) 93 aerosol 69, 70, 95

More information

LOCAL STORM DATA SHEET

LOCAL STORM DATA SHEET LOCAL STORM DETECTION > Storm detection: who is involved? > Regulations, storm phases and classification of detectors > ATSTORM local thunderstorm detector by measurement of electric field > STORM DETECTION:

More information

Risk Management Department. Fire Extinguishers

Risk Management Department. Fire Extinguishers Risk Management Department Fire 1 Introduction to Fire Every school facility is equipped with fire extinguishers for staff to use to suppress fires. Used properly, a fire extinguisher can be an effective

More information

Carbon Monoxide Safety Information

Carbon Monoxide Safety Information Aurora Fire Rescue City of Aurora Fire Administration 15151 E. Alameda Parkway, Suite 4100 Aurora, Colorado 80012 303.326.8999 Worth Discovering auroragov.org Carbon Monoxide Safety Information Aurora

More information

(Material correct at 1/11/2011)

(Material correct at 1/11/2011) NEBOSH International Diploma in Occupational Health & Safety Unit IC INTERNATIONAL WORKPLACE AND WORK EQUIPMENT SAFETY element IC3 WORKPLACE FIRE RISK ASSESSMENT Sample material (Material correct at 1/11/2011)

More information