B4512 Control Panels. Intrusion Alarm Systems B4512 Control Panels.

Size: px
Start display at page:

Download "B4512 Control Panels. Intrusion Alarm Systems B4512 Control Panels."

Transcription

1 Intrsion Alarm Systems B4512 Control Panels B4512 Control Panels Spports p to 28 points sing a combination of hardwired or wireless points for installation flexibility and 2 areas with perimeter and interior control On-board Ethernet port for Conettix IP alarm commnication and remote programming, compatible with modern IP networks inclding IPv6/ IPv4, Ato-IP and Universal Plg and Play Installer-friendly featres inclding on-board USB for easy on-site RPS programming, pls plg-in PSTN and Celllar commnication modles for simple installation and ftre proof pgrades Notifications with and text messaging, and the Remote Secrity Control app for Android and ios mobile devices Programmable keypad shortcts, sitation sensitive on-screen help, and a bilingal ser interface make system operation simple and easy The B4512 Control Panel integrates intrsion and residential fire, providing one simple ser interface for both systems. The B4512 provides p to 28 individally identified points that can be split into 2 areas. The control panel incldes a bilt-in Ethernet port for IP network commnications, and is compatible with modles that send events to selected pblic switched telephone network (PSTN), IP network, or celllar network destinations throgh for programmable rote grops. With the B4512, yo can monitor doors, windows, and motion within areas like showrooms or those that hold inventory. Each ser can have a personalized passcode, a wireless keyfob, and a credential to control the system. Use programmable athority levels with restricted privileges to provide service, secrity, and cleaning personnel with fll or limited access. Use the three programmable otpts (expandable p to 27) to trn on lights or open and lock doors. Users can: Trn on the system to secre the stock room while yo condct daily bsiness. Perform tests to ensre yor system is working properly. Set yor system to alarm immediately if a door opens. Activate the Watch featre so a tone sonds whenever a cstomer enters. Set a schedle for yor system to atomatically trn on at closing time. Use wireless secrity options to cstomize yor system.

2 2 B4512 Control Panels Central monitoring stations provide 24-hor system monitoring with access to vital services. Professional secrity personnel can test the system, monitor system activity, and alert the police, fire department, or other emergency response teams if necessary. Fnctions Programmable otpts 500 ma not to exceed 1.3 A total crrent for a brglary system, or not to exceed 1.0 A total crrent for hosehold fire applications 800 ma axiliary power at 12 VDC For alarm-otpt patterns Programmable bell test Three programmable otpts; one high crrent sing a relay, and two trigger otpts Otpt A contact rating is 3 Amps System response High-performance micro-controller provides indstry leading system response 20 cstom point indexes Selectable point response time Cross point capability Fire alarm verification Dangeros gas indicator incldes carbon monoxide (NFPA 720) Watch mode Schedled events (SKEDs) perform several fnctions, sch as trn on (arm) the system, trn off (disarm) the system, bypass and nbypass points, and control relays User interface Spervision of p to 8 keypads Cstom keypad text is flly programmable throgh RPS Fll fnction men inclding cstom fnctions Athority by area and 32 character name for each ser 14 cstom athority levels control ser s athority to change, add, or delete passcodes to disarm or bypass areas; and to start system tests Programmable primary and secondary langage by ser and keypad; select from English, Spanish, French, and Portgese Area programming offers a wide selection of different system configrations. Make area arming conditional on other areas (master or associate), if desired. Yo can configre any area for perimeter and interior arming, not reqiring a separate area for this fnction. For higher secrity applications, the Area Re-Arm featre garantees that areas are always rearmed, and are disarmed for no longer than a specific, configrable, amont of time (for example, service time). Cstom fnctions For added convenience, the installer can program cstom fnctions that allow cstomers to complete complex tasks with fewer keystrokes. For example, a cstom fnction can bypass a grop of points and arm the system, allowing the ser to perform this fnction with one easy command. Installers can se cstom fnctions to control a particlar room. Cstomers activate cstom fnctions with a keypad, with a keyfob, by falting a point, or atomatically as a schedled event (SKED). Passcode secrity Two-Man Rle - Reqires two people with two niqe passcodes to be present at the time of opening. Early Ambsh - Allows sers to verify that the facility is safe by reqiring two passcodes. The control panel sends a dress event if the ser does not enter the passcode a second time after inspecting the premises. Easy exit control The control panel changes from one On (armed) state to another On (armed) state withot trning off (disarming) the system. For example, if yo change the state from Part On (Perimeter Arm) to All On (Master Arm), the control panel complies and reports the change. Easy Exit Control redces the nmber of keystrokes, simplifying system operation. Programmable passcode-controlled men list Passcode-controlled shortcts provide sers only with the options and information pertinent to them, simplifying system operation. Flexible control The system provides the flexibility to choose added convenience or high secrity. For example, yo can restrict to a keypad's immediate local area trning on (arming) and trning off (disarming) the system with a passcode, even if the ser has access to other areas. This is particlarly sefl for high secrity areas, where a ser may have access to the area, bt wold prefer to only trn off (disarm) the area individally rather than with the rest of the system. Another option is to program the system to trn off all areas the ser can access from any keypad. Monitor Delay While disarmed, this featre sends a brg spervisory report to the central station receiver if a point is falted for a configrable amont of time (for example, a door left open). System sers The system spports p to 32 sers. Each ser can have a personalized passcode, a wireless keyfob, and a credential to control the system. User passcodes contain three to six digits. Yo can assign passcodes to one of 14 cstomized athority levels in each area and can be restricted to operate only dring certain times. Programmable primary and secondary langage by ser and keypad; select from English, Spanish, French, and Portgese. Commnication formats The control panel prioritizes and sends reports to for rote grops. Network commnication ses the Modem4 commnication format, whereas phone

3 3 B4512 Control Panels commnication ses Contact ID or Modem4 commnications formats. Each grop has a programmable primary and backp destination. The control panel provides flexible commnications for most central stations with reporting capabilities sch as: Individal point nmbers Opening or closing reports by ser and area nmber Remote programming attempts Diagnostic reports IP commnication The control panel ses the optional on-board Ethernet connector, B440 Conettix Plg-in Celllar Commnicator, B441 Conettix Plg-in CDMA Celllar Commnicator, B442 Plg-in GPRS Celllar Commnicator (Latin America), B443 Plg-in HSPA+ Celllar Commnicator (Canada), or B426 Conettix Ethernet Commnication Modle to commnicate with a Conettix D6600 or a Conettix D6100IPv6 Commnications Receiver/Gateway. Using Conettix IP commnication offers a secre path that incldes antireplay/anti-sbstittion featres and provides enhanced secrity with AES 256-bit encryption. The control panel spports Domain Name System (DNS) for both remote programming and central station commnication. DNS provides ease of se, eliminating the need to se static IP addresses as yor reporting destination, and accommodates a simple soltion for central station disaster recovery. IP Setp is available via the keypad Installer men and the remote programming software, eliminating the need to se complicated internet programming tools sch as ARP and Telnet. The control panel spports both IPv6 and IPv4 networks. For more information on the enhanced commnications capabilities, refer to RPS Help or the control panel's Program Entry Gide. Commnication paths The control panel accommodates p to for separate phone and for separate network paths to the central station receiver. When resetting alarms or trning a system on and off, the ser is identified by name and nmber. Personal notification The control panel can send text messages and s for personal notification over Ethernet or sing a celllar commnicator. Yo can configre p to 16 destinations sing a combination of celllar phone nmbers and addresses. Firmware pdates The system allows remote firmware pdates throgh Remote Programming Software (RPS) sing the RPS Firmware Update Wizard. The Firmware Update Wizard ses the on-board USB connection or optional IP connection (on-board Ethernet connection, B426 Conettix Ethernet Commnication Modle, B440 Conettix Plg-in Celllar Commnicator, B441 Conettix Plg-in CDMA Celllar Commnicator, B442 Plg-in GPRS Celllar Commnicator (Latin America), B443 Plg-in HSPA+ Celllar Commnicator (Canada)) to transmit the pdates. Control panel pdates. Remotely pdate the control panel firmware for easy featre enhancements withot replacing ROM chips. Modle pdate spport. Remotely pdate the firmware on connected SDI2 modles for easy featre enhancements withot visiting each individal modle. A wide variety of inpt options Each point: Accommodates normally open (NO) and normally closed (NC) devices with end of line (EOL) resistor spervision. Accepts programming for fire, gas, fire spervisory, or intrsion applications. Spports hardwired and wireless devices. Spports IP cameras by Bosch as point sorces. Secrity and fire detection The control panel provides eight on-board points, and p to 20 additional off-board points (depending on model and expansion interfaces). Yo can program individal points to monitor some types of brglar alarms, fire alarms, and spervision devices. Event log The event log stores local and reported events. The event log incldes time, date, event, area, point, and ser. View the event log from a keypad or se RPS to remotely retrieve event information. When the event log reaches a programmed threshold of stored events, it can send an optional report to a receiver. The log stores p to 127 local and reported events. Schedled events (SKEDs) The internal clock and calendar start individally schedled events (SKEDs). SKEDs perform fnctions sch as trn on or off, relay control, or point bypassing. The control panel offers: The control panel offers: Five schedled events with p to 25 different fnctions Two opening windows and two closing windows Two ser windows Day-of-week, date-of-month, or holiday only schedles One holiday schedle of 366 days (leap year) Programming Installers can perform limited programming on-site with a keypad (critical parameters; sch as accont IDs, central station and RPS IP addresses and phone nmbers, reporting formats, and more). They can also do fll programming on-site or remotely (attended or nattended) with RPS. A programmable system passcode prevents nathorized remote programming. Diagnostics Keypads and RPS offer diagnostic help for monitoring and trobleshooting. The diagnostics featres allow yo to view the stats of the on-board Ethernet

4 4 B4512 Control Panels connection, plg-in commnicators, and SDI2 devices, inclding inpts, otpts, and RF. The featres provide the stats of the control panel and its connected devices, sch as firmware version, power, and missing conditions. View the stats of each area. Diagnostics also inclde connection data for connected wireless and Ethernet devices. Certifications and approvals Region US UL Police Station Connected Brglar Alarm Units and Systems UL Local Brglar Alarm Units and Systems UL Holdp Alarm Units and Systems UL Hosehold Fire Warning System Units Transformers CX4010 Plg-in Transformer (18 VAC 22 VA 60 Hz) ICP TR1822 CAN Plg in Transformer (110 VAC primary, 18 VAC 22 VA secondary) Enclosres B10 Medim Control Panel Enclosre B11 Small Control Panel Enclosre B12 Monting Plate for D8103 Enclosre D2203 Enclosre D8103 Universal Enclosre (reqires a B12) D8108A Attack Resistant Enclosre (reqires a B12) D8109 Fire Enclosre (reqires a B12) Canada UL Hosehold Brglar Alarm System Units UL Proprietary Brglar Alarm Units and Systems UL Central Station Brglar Alarm Units FCC Part 15 Class B CP Control Panel Standard - Featres for False Alarm Redction CAN/ULC S303 - Local Brglar Alarm Units and Systems CAN/ULC S304 - Signal Receiving Centre and Premise Alarm Control Units CAN/ULC S545, Residential Fire Warning System Control Units ULC-ORD C Hosehold Brglar Alarm System Units Accessories B56 Keypad Srface Mont Box B96 Keypad Trim Bezel B99 USB Direct Connect Cable B Interconnect wiring cables (pack of 10) Detectors D285/TH Photoelectric Smoke Detector Heads FCC-380 Carbon Monoxide Detector Bosch conventional detectors, inclding Professional Series, Ble Line Gen2, Ble Line, Classic Line, Commercial Line, and Ceiling Mont motion detectors, as well as glass break, seismic, reqest-to-exit, photoelectric, heat, and smoke detectors. Region ULC-ORD C Proprietary Brglar Alarm Units and Systems CP Control Panel Standard - Featres for False Alarm Redction Certification USA UL S1871 CSFM see or website Canada ULC S1871 Installation/configration notes Compatible prodcts Keypads B942/B942W Toch Screen Keypad B930 ATM Style Alphanmeric Keypad (SDI2) B921C Two-line Capacitive Keypad B920 Two-line Alphanmeric Keypad (SDI2) B915 Basic Keypad Modles B201 2-wire Powered Loop Modle B208 Octo-inpt Modle B308 Octo-otpt Modle B426 Conettix Ethernet Commnication Modle B430 Plg-in Telephone Commnicator B440 Conettix Plg-in Celllar Commnicator B441 Conettix Plg-in CDMA Celllar Commnicator B442 Plg-in GPRS Celllar Commnicator (Latin America) B443 Plg-in HSPA+ Celllar Commnicator (Canada) B450 Conettix Plg-in Commnicator Interface B520 Axiliary Power Spply Modle B810 wireless receiver (RADION) B820 SDI2 Inovonics Interface Modle D113 Battery Lead Spervision Modle D125B Dal Class B Initiating Modle

5 5 B4512 Control Panels D129 Class A Initiating Modle D130 Axiliary Relay Modle D132A Smoke Detector Reversing Relay Modle D133/D134 Relay Modle D185 Reverse Polarity Signaling Modle D192G Class B, Style Y Bell Circit Spervision Programming Remote Programming Software (RPS or RPS LITE) v5.17 or higher Conettix receivers (Managed and configred with Conettix D6200 Programming/ Administration Software v2.00) Conettix D6600 Commnications Receiver/Gateway (with only D6641 line cards installed) with CPU version Conettix D6100IPv6 Commnications Receiver/Gateway with CPU version Conettix D6100i Commnications Receiver/Gateway with CPU version RADION wireless from Bosch B810 wireless receiver (RADION) RFBT-A bill trap RFDL-11-A TriTech motion detector RFDW-RM-A recessed mont door/window contact RFDW-SM-A srface mont door/window contact RFGB-A glass break detector RFIN-A inertia detector RFKF-A two-btton keyfob RFKF-FB-A for-btton keyfob RFKF-TB-A two-btton keyfob RFPB-SB-A single-btton panic RFPB-TB-A two-btton panic RFRP-A repeater RFSM-A smoke detector RFPR-12-A PIR motion detector RFPR-C12-A PIR crtain motion detector RFUN-A niversal transmitter Inovonics Wireless B820 SDI2 Inovonics Interface Modle ENKIT-SDI2 SDI2 Inovonics Interface and Receiver Kit. Incldes B820 and EN4200 EN1210 Universal Transmitter (Single-inpt) EN1210EOL Universal Transmitter with EOL Resistor EN1210W Door-Window Transmitter with Reed Switch EN1215EOL Universal Transmitter with Wall Tamper, Reed Switch, and EOL Resistor EN1223D Water resistant Pendant Transmitter (Doble btton) EN1223S Water resistant Pendant Transmitter (Single btton) EN1224-ON Mltiple-Condition Pendant Transmitter EN1233D Necklace Pendant Transmitter (Doble-btton) EN1233S Necklace Pendant Transmitter (Single-btton) EN1235D Beltclip Pendant Transmitter (Doble-btton) EN1235DF Fixed-location Transmitter (Doble-btton) EN1235S Beltclip Pendant Transmitter (Single-btton) EN1235SF Fixed-location Transmitter (Single-btton) EN1247 Glass-break Detector Transmitter EN1249 Bill Trap Transmitter EN1242 Smoke Detector Transmitter EN1260 Wall Mont Motion Detector EN1261HT High Traffic Motion Detector EN1262 Motion Detector with Pet Immnity EN Ceiling Mont Motion Detector EN4200 Serial Receiver EN5040-T High Power Repeater with Transformer Parts inclded The B4512 incldes the following: Qant. Component 1 B4512 board 1 Literatre pack UL Installation Instrctions Owner s Manal Release Notes SIA Qick Reference Gide 1 Literatre CD containing prodct literatre The B4512E is available only in kits. Refer to Ordering information. Each B4512E control panel kit incldes the following: Qant. Component 1 B4512E board (withot on-board Ethernet port) 1 Plg-in commnicator (telephone or celllar, depending on the kit) 1 Plg-in Transformer (18 VAC 22 VA 60 Hz) 1 Control panel enclosre (kit dependent)

6 6 B4512 Control Panels 1 Literatre pack UL Installation Gide Owner s Manal Release Notes SIA Qick Reference Gide For kits, refer to Special (B Series Kits) on the Docments tab of the control panel s Prodct Page at s.boschsecrity.com. Order nmber B4512 (for individal B4512 control panels) 1 Literatre CD containing prodct literatre Technical specifications Commnications Ethernet One on-board Ethernet connector* Environmental considerations Relative hmidity 5% to 93% at +90 (+32 ), non condensing Temperatre (operating) +32 F to +122 F (0 C to +49 C) Nmber of Areas 2 Cstom fnctions 2 Events Up to 127 Passcode sers 32, pls 1 Installer passcode Points 28 (8 on board, p to 20 off board) Programmable otpts 27 (3 on board, p to 24 off board) RF points 20 SKEDs 5 Power Reqirements Crrent draw (maximm) Otpt (alarm) Otpt (axiliary, continos power, and switched axiliary combined): Voltage (operating): Idle 125 ma; Alarm 155 ma 1.3 A at 12 VDC 800 ma at 12 VDC nominal 12 VDC nominal Voltage (AC): CX4010 UL Listed Class 2 Transformer 18 VAC 22 VA 60 HZ *The E control panels do not inclde an on-board Ethernet connector. Trademarks All hardware and software prodct names sed in this docment are likely to be registered trademarks and mst be treated accordingly. Ordering information B4512/B4512E The B4512 is available individally or in kits. The B4512E is available only in kits.

7 7 B4512 Control Panels Represented by: Americas: Erope, Middle East, Africa: Asia-Pacific: China: America Latina: Bosch Secrity Systems, Inc. Bosch Secrity Systems B.V. Robert Bosch (SEA) Pte Ltd, Secrity Bosch (Shanghai) Secrity Systems Ltd. Robert Bosch Ltda Secrity Systems Division 130 Perinton Parkway Fairport, New York, 14450, USA Phone: Fax: P.O. Box BA Eindhoven, The Netherlands Phone: Fax: emea.secritysystems@bosch.com Systems 11 Bishan Street 21 Singapore Phone: Fax: apr.secritysystems@bosch.com Bilding, No. 333 Fqan Road North IBP Changning District, Shanghai China Phone Fax: Via Anhangera, Km 98 CEP Campinas, Sao Palo, Brazil Phone: Fax: latam.boschsecrity@bosch.com Bosch Secrity Systems 2014 Data sbject to change withot notice en, V19, 04. Nov 2014

B3512 Control Panels. Intrusion Alarm Systems B3512 Control Panels.

B3512 Control Panels. Intrusion Alarm Systems B3512 Control Panels. Intrsion Alarm Systems B3512 Control Panels B3512 Control Panels www.boschsecrity.com Spports p to 16 points sing 8 on-board and 8 wireless points for installation flexibility with perimeter and interior

More information

B5512 Control Panels. Intrusion Alarm Systems B5512 Control Panels.

B5512 Control Panels. Intrusion Alarm Systems B5512 Control Panels. Intrsion Alarm Systems B5512 Control Panels B5512 Control Panels www.boschsecrity.com Spports a combination of p to 48 hardwired or wireless points for installation flexibility and p to 4 areas with perimeter

More information

B5512 Control Panels. Intrusion Alarm Systems B5512 Control Panels.

B5512 Control Panels. Intrusion Alarm Systems B5512 Control Panels. Intrsion Alarm Systems B5512 Control Panels B5512 Control Panels www.boschsecrity.com Spports p to 48 points sing a combination of hardwired or wireless points for installation flexibility and p to 4 areas

More information

B3512 Control Panels. Intrusion Alarm Systems B3512 Control Panels.

B3512 Control Panels. Intrusion Alarm Systems B3512 Control Panels. Intrsion Alarm Systems B3512 Control Panels B3512 Control Panels www.boschsecrity.com Spports p to 16 points sing 8 on-board and 8 wireless points for installation flexibility with perimeter and interior

More information

B5512 Control Panels. Intrusion Alarm Systems B5512 Control Panels.

B5512 Control Panels. Intrusion Alarm Systems B5512 Control Panels. Intrsion Alarm Systems B5512 Control Panels B5512 Control Panels www.boschsecrity.com Spports p to 48 points sing a combination of hardwired or wireless points for installation flexibility and p to 4 areas

More information

B9512G Control Panels

B9512G Control Panels Intrsion Alarm Systems B9512G Control Panels B9512G Control Panels www.boschsecrity.com Flly integrated intrsion, fire, and access control allows sers to interface with one system instead of three Spports

More information

B9512G Control Panel. Intrusion Alarm Systems B9512G Control Panel.

B9512G Control Panel. Intrusion Alarm Systems B9512G Control Panel. Intrsion Alarm Systems B9512G Control Panel B9512G Control Panel www.boschsecrity.com Flly integrated intrsion, fire, and access control allows sers to interface with one system instead of three Spports

More information

D7212GV4 Series Control Panels

D7212GV4 Series Control Panels Intrsion Alarm Systems D7212GV4 Series Control Panels D7212GV4 Series Control Panels www.boschsecrity.com Flly integrated intrsion and fire, allows sers to interface with one system instead of two Conettix

More information

B440 Conettix Plug-in Cellular Communicator

B440 Conettix Plug-in Cellular Communicator Intrsion Alarm Systems B440 Conettix Plg-in Celllar Commnicator B440 Conettix Plg-in Celllar Commnicator www.boschsecrity.com Secre Conettix IP commnication from compatible Bosch panels to Bosch receivers

More information

B4512 Control Panels. Intrusion Alarm Systems B4512 Control Panels.

B4512 Control Panels. Intrusion Alarm Systems B4512 Control Panels. Intrsion Alarm Systems B4512 Control Panels B4512 Control Panels www.boschsecrity.com Provides p to 28 points sing a combination of hardwired or wireless points for installation flexibility and 2 areas

More information

B465 Universal Dual Path Communicator

B465 Universal Dual Path Communicator Intrsion Alarm Systems B465 Universal Dal Path Commnicator B465 Universal Dal Path Commnicator www.boschsecrity.com The B465 Conettix Universal Dal Path Commnicator converts the Pblic Switch Telephone

More information

B5512 Control Panels. Intrusion Alarm Systems B5512 Control Panels.

B5512 Control Panels. Intrusion Alarm Systems B5512 Control Panels. Intrsion Alarm Systems B5512 Control Panels B5512 Control Panels www.boschsecrity.com Provides p to 48 points sing a combination of hardwired or wireless points for installation flexibility and p to 4

More information

B6512 IP control panel, 96 points

B6512 IP control panel, 96 points Intrsion Alarm Systems B6512 IP control panel, 96 points B6512 IP control panel, 96 points www.boschsecrity.com Provides p to 96 points sing a combination of hardwired or wireless devices for installation

More information

B6512 IP control panel, 96 points

B6512 IP control panel, 96 points Intrsion Alarm Systems B6512 IP control panel, 96 points B6512 IP control panel, 96 points www.boschsecrity.com Provides p to 96 points sing a combination of hardwired or wireless devices for installation

More information

B465 Universal Dual Path Communicator

B465 Universal Dual Path Communicator Intrsion Alarm Systems B465 Universal Dal Path Commnicator B465 Universal Dal Path Commnicator www.boschsecrity.com The B465 Conettix Universal Dal Path Commnicator converts the Pblic Switch Telephone

More information

AMAX panel Intrusion Alarm Systems AMAX panel hardwired zones / 2 areas / 64 user codes

AMAX panel Intrusion Alarm Systems AMAX panel hardwired zones / 2 areas / 64 user codes Intrsion Alarm Systems AMAX panel 2100 AMAX panel 2100 www.boschsecrity.com 8 hardwired zones / 2 areas / 64 ser codes 3 x 256 events log stamped with date and time On-board voice dialer Macro fnctionality

More information

ICP-AMAX2-P2-EN Intrusion panel, fr/de/nl/pt

ICP-AMAX2-P2-EN Intrusion panel, fr/de/nl/pt Intrsion Alarm Systems ICP-AMAX2-P2-EN Intrsion panel, fr/de/nl/pt ICP-AMAX2-P2-EN Intrsion panel, fr/de/nl/pt www.boschsecrity.com 8 hardwired zones / 2 areas / 64 ser codes On-board voice dialer Macro

More information

ICP-AMAX3-P2-BE Intrusion panel, fr/de/nl/pt

ICP-AMAX3-P2-BE Intrusion panel, fr/de/nl/pt Intrsion Alarm Systems ICP-AMAX3-P2-BE Intrsion panel, fr/de/nl/pt ICP-AMAX3-P2-BE Intrsion panel, fr/de/nl/pt www.boschsecrity.com 32 zones / 8 areas / 128 ser codes On-board voice dialer Macro fnctionality

More information

ICP-AMAX3-P2-EN Intrusion panel, fr/de/nl/pt

ICP-AMAX3-P2-EN Intrusion panel, fr/de/nl/pt Intrsion Alarm Systems ICP-AMAX3-P2-EN Intrsion panel, fr/de/nl/pt ICP-AMAX3-P2-EN Intrsion panel, fr/de/nl/pt www.boschsecrity.com 32 zones / 8 areas / 128 ser codes On-board voice dialer Macro fnctionality

More information

B465 Universal Dual Path Communicator

B465 Universal Dual Path Communicator Intrsion Alarm Systems B465 Universal Dal Path Commnicator B465 Universal Dal Path Commnicator www.boschsecrity.com Compatible with control panels sing Contact ID, SIA, Plse 3/1 or Plse 4/2 commnication

More information

D2212BE Control Panel

D2212BE Control Panel Intrsion Alarm Systems DBE Control Panel DBE Control Panel www.boschsecrity.com Eight (maximm) on-board points Eight sers and passcodes with three athority levels Two programmable on-board relay otpts

More information

D9412GV2 Control Panel

D9412GV2 Control Panel Intrsion Alarm Systems D9412GV2 Control Panel D9412GV2 Control Panel www.boschsecrity.com Flly integrated intrsion, fire, and access control allows sers to interface with one system instead of three Conettix

More information

GEC Low-frequency Horn Strobes

GEC Low-frequency Horn Strobes Fire Alarm Systems GEC Low-freqency Horn Strobes GEC Low-freqency Horn Strobes Silence the horn while strobes flash Evacation tone Use the SperSlide featre for easy testing Wide voltage range; 16 to 33

More information

ICP-AMAX4-P3-EN Intrusion panel, en/es/pl/sv

ICP-AMAX4-P3-EN Intrusion panel, en/es/pl/sv Intrsion Alarm Systems ICP-AMAX4-P3-EN Intrsion panel, en/es/pl/sv ICP-AMAX4-P3-EN Intrsion panel, en/es/pl/sv www.boschsecrity.com 64 zones / 16 areas / 250 ser codes On-board voice dialer Macro fnctionality

More information

D7412GV3 Control Panel

D7412GV3 Control Panel Intrsion Alarm Systems D7412GV3 Control Panel D7412GV3 Control Panel www.boschsecrity.com Flly integrated intrsion, fire, and access control allows sers to interface with one system instead of three Conettix

More information

AMAX panel Intrusion Alarm Systems AMAX panel zones / 8 areas / 128 user codes. On-board voice dialer

AMAX panel Intrusion Alarm Systems AMAX panel zones / 8 areas / 128 user codes. On-board voice dialer Intrsion Alarm Systems AMAX panel 3000 AMAX panel 3000 www.boschsecrity.com 32 zones / 8 areas / 128 ser codes On-board voice dialer Macro fnctionality USB direct connection This hybrid panel is designed

More information

D7412GV3 Control Panel

D7412GV3 Control Panel Intrsion Alarm Systems D7412GV3 Control Panel D7412GV3 Control Panel www.boschsecrity.com Flly integrated intrsion, fire, and access control allows sers to interface with one system instead of three Conettix

More information

D2212B Control Panel. Intrusion Alarm Systems D2212B Control Panel. Eight on-board points. Up to 24 wired or wireless points

D2212B Control Panel. Intrusion Alarm Systems D2212B Control Panel.   Eight on-board points. Up to 24 wired or wireless points Intrsion Alarm Systems DB Control Panel DB Control Panel www.boschsecrity.com Eight on-board points Up to wired or wireless points Eight sers and passcodes with three athority levels Two programmable on-board

More information

CC600PB Solution 144 Control Panel

CC600PB Solution 144 Control Panel Intrsion Alarm Systems CC600PB Soltion 144 Control Panel CC600PB Soltion 144 Control Panel www.boschsecrity.com 16 on-board zones (expandable to 144 wired or wireless), partitionable to 8 areas with 256

More information

Blue Line Gen2 TriTech Motion Detectors

Blue Line Gen2 TriTech Motion Detectors Intrsion Alarm Systems Ble Line Gen2 TriTech Motion Detectors Ble Line Gen2 TriTech Motion Detectors www.boschsecrity.com Pet friendly Selectable model available optimize installation for pet (45 kg [00

More information

Blue Line Gen2 TriTech Motion Detectors

Blue Line Gen2 TriTech Motion Detectors Intrsion Alarm Systems Ble Line Gen2 TriTech Motion Detectors Ble Line Gen2 TriTech Motion Detectors www.boschsecrity.com Pet friendly Selectable model available optimize installation for pet (45 kg [00

More information

Loudspeakers Line Isolator System

Loudspeakers Line Isolator System Commnications Systems Lodspeakers Line Isolator System Lodspeakers Line Isolator System www.boschsecrity.com Provides redndant lodspeaker loops for pblic address and voice alarm systems Dramatically redces

More information

AMAX3-P2ENG Intrusion kit, fr/de/nl/pt, GPRS

AMAX3-P2ENG Intrusion kit, fr/de/nl/pt, GPRS Intrsion Alarm Systems AMAX3-P2ENG Intrsion kit, fr/de/nl/pt, GPRS AMAX3-P2ENG Intrsion kit, fr/de/nl/pt, GPRS www.boschsecrity.com This kit incldes the following: One AMAX panel with langage package 2:

More information

ISC PPR1 WA16x Professional Series PIR Detectors with Anti mask

ISC PPR1 WA16x Professional Series PIR Detectors with Anti mask Intrsion Alarm Systems ISC PPR WA6x Professional Series PIR Detectors with Anti mask ISC PPR WA6x Professional Series PIR Detectors with Anti mask www.boschsecrity.com 6 m x m (5 x 7) standard coverage;

More information

Professional Series LSN TriTech+ Motion Detectors with Anti mask

Professional Series LSN TriTech+ Motion Detectors with Anti mask Intrsion Alarm Systems Professional Series LSN TriTech+ Motion Detectors with Professional Series LSN TriTech+ Motion Detectors with www.boschsecrity.com 8 m x 5 m (60 ft x 80 ft) standard coverage; 8

More information

LBB 1990/00 Plena Voice Alarm Controller

LBB 1990/00 Plena Voice Alarm Controller Commnications Systems LBB 1990/00 Plena Voice Alarm Controller LBB 1990/00 Plena Voice Alarm Controller www.boschsecrity.com Heart of the Plena Voice Alarm System EN 54 16 certified and EN 60849 compliant

More information

Commercial Series TriTech+ Motion Detectors with Anti-mask

Commercial Series TriTech+ Motion Detectors with Anti-mask Intrsion Alarm Systems Commercial Series TriTech+ Motion Detectors with Anti-mask Commercial Series TriTech+ Motion Detectors with Anti-mask www.boschsecrity.com GHz Active infrared anti-mask - Detects

More information

LBB 1990/00 Plena Voice Alarm Controller

LBB 1990/00 Plena Voice Alarm Controller Commnications Systems LBB 1990/00 Plena Voice Alarm Controller LBB 1990/00 Plena Voice Alarm Controller www.boschsecrity.com Heart of the Plena Voice Alarm System EN 54 16 certified and EN 60849 compliant

More information

FMC 420RW Single Action Call Points LSN improved

FMC 420RW Single Action Call Points LSN improved Fire Alarm Systems FMC 420RW Single Action Call Points LSN improved FMC 420RW Single Action Call Points LSN improved www.boschsecrity.com Alarm triggering by pressing the black marking or breaking the

More information

FPA 1000 UL Analog Addressable Fire Panel

FPA 1000 UL Analog Addressable Fire Panel Fire Alarm Systems FPA 1000 UL Analog Addressable Fire Panel FPA 1000 UL Analog Addressable Fire Panel www.boschsecrity.com Spport for p to 508 points on two analog addressable loops Bilt in Ethernet connector

More information

Fireray5000-EN. Fire Alarm Systems Fireray5000-EN. Extended monitoring range. Up to 2 detectors per system controller

Fireray5000-EN. Fire Alarm Systems Fireray5000-EN.  Extended monitoring range. Up to 2 detectors per system controller Fire Alarm Systems Fireray5000-EN Fireray5000-EN www.boschsecrity.com Extended monitoring range Up to 2 detectors per system controller Two pairs of fire and falt relays (one per detector) Transmitter

More information

LA1 UMx0E Metal Column Loudspeakers

LA1 UMx0E Metal Column Loudspeakers Commnications Systems LA1 UMxE Metal Colmn Lodspeakers LA1 UMxE Metal Colmn Lodspeakers www.boschsecrity.com Good speech intelligibility and backgrond msic reprodction For applications where directivity

More information

FMC 420RW Single Action Call Points LSN improved

FMC 420RW Single Action Call Points LSN improved Fire Alarm Systems FMC 420RW Single Action Call Points LSN FMC 420RW Single Action Call Points LSN Alarm triggering by pressing the black marking or breaking the glass pane Protection against injry throgh

More information

Professional Series TriTech+ Motion Detectors with Anti mask

Professional Series TriTech+ Motion Detectors with Anti mask Intrsion Alarm Systems Professional Series TriTech+ Motion Detectors with Anti mask Professional Series TriTech+ Motion Detectors with Anti mask www.boschsecrity.com 8 m x 5 m (60 ft x 80 ft) standard

More information

LH1 UC30E Music Horn Loudspeaker

LH1 UC30E Music Horn Loudspeaker Commnications Systems LH1 UC3E Msic Horn Lodspeaker LH1 UC3E Msic Horn Lodspeaker www.boschsecrity.com Excellent speech and msic reprodction Two way system Attractive ABS hosing Provisions for internal

More information

LA1 UMx0E 1 Metal Column Loudspeakers

LA1 UMx0E 1 Metal Column Loudspeakers Commnications Systems LA UMxE Metal Colmn Lodspeakers LA UMxE Metal Colmn Lodspeakers www.boschsecrity.com Good speech intelligibility and backgrond msic reprodction For applications where directivity

More information

FPA 1000 Analog Addressable Fire Panels

FPA 1000 Analog Addressable Fire Panels Fire Alarm Systems FPA 1000 Analog Addressable Fire Panels FPA 1000 Analog Addressable Fire Panels www.boschsecrity.com Spport for p to 508 points on two analog addressable loops Bilt-in Ethernet connector

More information

LC4 Ceiling Loudspeaker Range

LC4 Ceiling Loudspeaker Range Commnications Systems LC4 Ceiling Lodspeaker Range LC4 Ceiling Lodspeaker Range www.boschsecrity.com Innovative CosCone fll range driver Excellent speech and msic reprodction Unrivalled opening angle for

More information

System Sensor L-series indoor horn/ strobes

System Sensor L-series indoor horn/ strobes Fire Alarm Systems System Sensor L-series indoor horn/strobes System Sensor L-series indoor horn/ strobes www.boschsecrity.com Plg-in design with minimal intrsion into the back box Field-selectable candela

More information

Integrated Security Solutions

Integrated Security Solutions Integrated Security Solutions Table of Contents Control Panels 4 Keypads 8 Communication Modules 16 I/O Expanders 20 Door Control 24 Home Automation 25 RF Receivers 26 3 Our integrated security solutions

More information

FAP 520 Automatic Fire Detectors LSN improved version

FAP 520 Automatic Fire Detectors LSN improved version Fire Alarm Systems FAP 520 Atomatic Fire Detectors LSN improved version FAP 520 Atomatic Fire Detectors LSN improved version www.boschsecrity.com Modern, ltra-flat design Smooth, easily-cleaned detector

More information

LSN RF Fire Detection System

LSN RF Fire Detection System 17 19 18 34 3 50 49 21 20 36 35 52 51 23 2 38 37 54 53 24 10 26 25 40 39 5 57 56 13 12 28 27 42 41 59 58 15 14 30 29 4 43 61 60 16 32 31 46 45 63 62 48 47 64 Fire Alarm Systems LSN RF Fire Detection System

More information

LBC 3011/x1 Panel Loudspeakers

LBC 3011/x1 Panel Loudspeakers Commnications Systems LBC 311/x1 Panel Lodspeakers LBC 311/x1 Panel Lodspeakers High-qality speech and msic reprodction Two-way system Simple power setting Flsh-monting in walls, ceilings, or frnitre Srface-monting

More information

LBC 3200/00 Line Array Indoor Loudspeaker

LBC 3200/00 Line Array Indoor Loudspeaker Commnications Systems LBC 3200/00 Line Array Indoor Lodspeaker LBC 3200/00 Line Array Indoor Lodspeaker www.boschsecrity.com Extended listening area Excellent intelligibility of speech and msic Uniform

More information

Integrated Security Solutions

Integrated Security Solutions Integrated Security Solutions Table of Contents Control Panels 4 Keypads 8 Communication Modules 16 I/O Expanders 20 Door Control 24 Home Automation 25 RF Receivers 26 2 Our integrated security solutions

More information

FMC 210 DM Double Action Call Points

FMC 210 DM Double Action Call Points Fire Alarm Systems FMC 10 DM Doble Action Call Points FMC 10 DM Doble Action Call Points www.boschsecrity.com Adjstment after alarm triggering Individal identification thanks to atomatic or manal detector

More information

BIS - Overview and basic package V3.0

BIS - Overview and basic package V3.0 Engineered Soltions BIS - Overview and basic package V3.0 BIS - Overview and basic package V3.0 www.boschsecrity.com Complete enterprise management for efficient, integrated bilding and secrity management

More information

LBC 3201/00 Line Array Indoor Loudspeaker

LBC 3201/00 Line Array Indoor Loudspeaker Commnications Systems LBC 3201/00 Line Array Indoor Lodspeaker LBC 3201/00 Line Array Indoor Lodspeaker www.boschsecrity.com Extended listening area Excellent intelligibility of speech and msic Uniform

More information

Conettix D6100IPv6 Communications Receiver/Gateway

Conettix D6100IPv6 Communications Receiver/Gateway Intrsion Alarm Systems Conettix D6100IPv6 Commnications Receiver/Gateway Conettix D6100IPv6 Commnications Receiver/Gateway www.boschsecrity.com Up to 3,200 acconts for local-area network (LAN) or wide-area

More information

B8512G Control Panels

B8512G Control Panels Intrusion Alarm Systems B8512G Control Panels B8512G Control Panels www.boschsecurity.com u u u u u Fully integrated intrusion, fire, and access control allows users to interface with one system instead

More information

FAS 420 Series Aspirating Smoke Detectors LSN improved version

FAS 420 Series Aspirating Smoke Detectors LSN improved version Fire Alarm Systems FAS 420 Series Aspirating Smoke Detectors LSN improved version FAS 420 Series Aspirating Smoke Detectors LSN improved version www.boschsecrity.com Connectable to the fire panels FPA

More information

B9512G Control Panels

B9512G Control Panels Intrusion Alarm Systems B9512G Control Panels B9512G Control Panels www.boschsecurity.com The B9512G Control Panel and the B8512G Control Panel are the new premier commercial control panels from Bosch.

More information

AMAX Intrusion Alarm Systems System overview

AMAX Intrusion Alarm Systems System overview Operating and Programming Extensions Alarm A-Link Keypads 8 Zone Input Module * Output Module IP communicator Wired IP/GPRS transmission Monitoring Center (Communications Receiver/Gateway) Option Bus GPRS

More information

LH1 UC30E Music Horn Loudspeaker

LH1 UC30E Music Horn Loudspeaker Commnications Systems LH1 UC3E Msic Horn Lodspeaker LH1 UC3E Msic Horn Lodspeaker www.boschsecrity.com Excellent speech and msic reprodction Two way system Attractive ABS hosing Provisions for internal

More information

LBC 3210/00 Line Array Indoor/Outdoor Loudspeaker

LBC 3210/00 Line Array Indoor/Outdoor Loudspeaker Commnications Systems LBC 3210/00 Line Array Indoor/Otdoor Lodspeaker LBC 3210/00 Line Array Indoor/Otdoor Lodspeaker www.boschsecrity.com Extended listening area Excellent intelligibility of speech and

More information

FPA 1000 Analog Addressable Fire Panels

FPA 1000 Analog Addressable Fire Panels Fire Alarm Systems FPA 1000 Analog Addressable Fire Panels FPA 1000 Analog Addressable Fire Panels www.boschsecrity.com Spport for p to 508 points on two analog addressable loops Bilt-in Ethernet connector

More information

LC4 Ceiling Loudspeaker Range

LC4 Ceiling Loudspeaker Range Commnications Systems LC4 Ceiling Lodspeaker Range LC4 Ceiling Lodspeaker Range www.boschsecrity.com Innovative CosCone fll range driver Excellent speech and msic reprodction Unrivalled opening angle for

More information

LB1 UMx0E Premium sound Cabinet Loudspeaker Range

LB1 UMx0E Premium sound Cabinet Loudspeaker Range ommnications Systems LB1 UMxE Premim sond abinet Lodspeaker Range LB1 UMxE Premim sond abinet Lodspeaker Range High-fidelity msic and speech reprodction Spplied with adjstable wall monting bracket Self

More information

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version Fire Alarm Systems FAP-420/FAH-420 Atomatic Fire Detectors LSN improved version FAP-420/FAH-420 Atomatic Fire Detectors LSN improved version www.boschsecrity.com Combination of optical, thermal and chemical

More information

Control Panels D9412GV4/D7412GV4 v2.03. Installation and System Reference Guide

Control Panels D9412GV4/D7412GV4 v2.03. Installation and System Reference Guide Control Panels D9412GV4/D7412GV4 v2.03 en Installation and System Reference Guide D9412GV4/D7412GV4 v2.03 Installation and System Reference Guide Certifications and Approvals Certifications and Approvals

More information

FPA 5000 With Functional Modules

FPA 5000 With Functional Modules Fire Alarm Systems FPA 5000 With Fnctional Modles FPA 5000 With Fnctional Modles www.boschsecrity.com Modlar configration allowing for easy extension nterconnection of p to 32 Panel Controllers, Remote

More information

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation. G SERIES: Security INTEGRATION as you want it Greater expansion, communication, video integration, system resilience, and automation. G Series Integrated Security Solution Fire Intrusion Access Greater

More information

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version Fire Alarm Systems FAP-420/FAH-420 Atomatic Fire s LSN improved version FAP-420/FAH-420 Atomatic Fire s LSN improved version www.boschsecrity.com Combination of optical, thermal and chemical sensors with

More information

Integrated Security Solutions. B and G Series Control Panels

Integrated Security Solutions. B and G Series Control Panels Integrated Security Solutions B and G Series Control Panels 1 Table of Contents Control Panels 3 Keypads 7 Communication Modules 13 Power 18 I/O Expanders 19 Door Control 23 Home Automation 24 RF Receivers

More information

FCS-8000-VFD-B Video-based fire detection

FCS-8000-VFD-B Video-based fire detection Fire Alarm Systems FCS-8000-VFD-B Video-based fire detection FCS-8000-VFD-B Video-based fire detection www.boschsecrity.com Very fast fire and smoke detection Robst against false alarms Covers large monitoring

More information

Designed for integration. B Series and G Series Control Panels

Designed for integration. B Series and G Series Control Panels Designed for integration B Series and G Series Control Panels 1 Table of contents Intelligent Control Panels 3 Keypads 7 Communication Modules 13 Power 18 I/O Expanders 19 Door Control 23 Home and Business

More information

WARNING Important Safety Information

WARNING Important Safety Information 2 Installation Premier Series Non-Programmable Thermostats MODEL 3300 Mlti-Stage 3 Heat / 2 Cool Ato Changeover Conventional and Heat Pmp Before Installing or Operating, PLEASE READ ALL INSTRUCTIONS 1

More information

Control Panel. D9412GV4/D7412GV4 v2.00. en UL Installation Instructions

Control Panel. D9412GV4/D7412GV4 v2.00. en UL Installation Instructions Control Panel D9412GV4/D7412GV4 v2.00 en UL Installation Instructions Control Panel Table of Contents en 3 Table of contents 1 Introduction 4 1.1 About documentation 4 1.2 Determine Bosch Security Systems,

More information

G Series Control Panels Quick Guide. September 2017

G Series Control Panels Quick Guide. September 2017 G Series Control Panels Quick Guide September 2017 1 Control Panels GV4 G Series Commercial Type Number D7212GV4 D7412GV4 D9412GV4 B8512G B9512G Integration Residential Fire Access Control, Residential

More information

B Series Quick Reference Guide Intrusion Small Commercial/Retail/Banking

B Series Quick Reference Guide Intrusion Small Commercial/Retail/Banking B Series Quick Reference Guide Intrusion Small Commercial/Retail/Banking B3512/B4512/B5512 Conventional Devices D125B Dual Class B Initiating Reversing Relay Control Mobile App G100 Z-Wave Home Control

More information

TETRA Secury System funkwerk TSS: The future of professional mobile communication.

TETRA Secury System funkwerk TSS: The future of professional mobile communication. TETRA Secry System fnkwerk TSS: The ftre of professional mobile commnication. The TETRA-based radio alarm system with telephony integration and precise localisation Fnkwerk Secrity Commnications Secrity.

More information

Control Panel-Based Alarm System

Control Panel-Based Alarm System Control Panel-Based Alarm System Installation Programming Operating Keep this manal safe for reference and ftre maintenance Introdction Contents Thank yo for choosing the Yale Wireless Alarm System. This

More information

Professional Series Intrusion Detector Knows when to alarm. Knows when not to. Back. Now Featuring Multi-Point Anti-Mask with Spray Detect

Professional Series Intrusion Detector Knows when to alarm. Knows when not to. Back. Now Featuring Multi-Point Anti-Mask with Spray Detect Professional Series Intrsion Detector Knows when to alarm. Knows when not to. Back Now Featring Mlti-Point Anti-Mask with Spray Detect Intelligent motion detection with nmatched versatility If yo cold

More information

B and G Series Integrated Security Solution

B and G Series Integrated Security Solution B and G Series Integrated Security Solution Integrated Security Solution Greater protection B and G Series Control Panels are approved for combination burglar and fire alarm applications (UL certified),

More information

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2 Architectural & Engineering Specifications Control Panel 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality assurance...

More information

DS7400Xi Addressable Control/ Communicator

DS7400Xi Addressable Control/ Communicator DS7400Xi Addressable Control/ Communicator DS7400Xi DS7400Xi-EXP 110VAC operation 220VAC operation Remotely Programmable WDSRP (Windows Detection Systems Remote Programming Software), allows the systems

More information

MODEL FTGF2P (240 VAC)

MODEL FTGF2P (240 VAC) SUMMARY MODEL FTGF2P (240 VAC) OPTIONS SELECTION At the back of the thermostat, there are two selection switches to set yor preference. 1 2 Temperatre in C or F. Time in 12 or 24 hors. TO SET TIME AND

More information

G Series Control Panels Quick Guide. February 2017

G Series Control Panels Quick Guide. February 2017 G Series Control Panels Quick Guide February 2017 1 Control Panels GV4 G Series Commercial Type Number D7212GV4 D7412GV4 D9412GV4 B8512G B9512G Applications Access Control Access Control IP Video, Access

More information

Easy Series Control Panel ICP-EZM2

Easy Series Control Panel ICP-EZM2 Easy Series Control Panel ICP-EZM2 en Quick Installation Guide Easy Series Control Panel Table of contents en 3 Table of contents 1 Install the Enclosure 4 2 Wire the Control Panel 6 3 Configure the System

More information

Control/Communicator

Control/Communicator Architectural & Engineering Specifications Control/Communicator 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality

More information

Buderus Oil Boilers. Buderus G115 & G215.

Buderus Oil Boilers. Buderus G115 & G215. Bders Oil Boilers Bders G115 & G215 Bders residential oil boilers are designed to extract and deliver more heat from every fel dollar, and are available in higher otpts at less cost per BTU. www.boschheatingandcooling.com

More information

Control Panels B9512G/B8512G (B9512G E/B8512G E) Installation Manual

Control Panels B9512G/B8512G (B9512G E/B8512G E) Installation Manual Control Panels B9512G/B8512G (B9512G E/B8512G E) en Installation Manual Control Panels Table of contents en 3 Table of contents 1 Certifications, approvals, listings, and safety 9 1.1 Listings and approvals

More information

6 Advanced Programming

6 Advanced Programming 6 Advanced Programming 6.1 Program Codes This chapter provides the Program Codes table which smmarizes the wide variety of available programming operations, along with a description and comments. Additional

More information

UltraSync Modular Hub

UltraSync Modular Hub Intrusion UltraSync Modular Hub UM-5000-CPU OVERVIEW The UltraSync Modular Hub is a smart security system ideal for residential installations requiring hardwired and/or wireless intrusion systems, as well

More information

UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers

UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers Intrusion Systems UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers Up to 6 UEZ LSNs can be networked with system loop technology (SRT) Fire

More information

D3D Wi-Fi GSM Smart Alarm System -User Manual

D3D Wi-Fi GSM Smart Alarm System -User Manual D3D Wi-Fi GSM Smart Alarm System -User Manual D3D Wi-Fi / GSM Smart Alarm system (Model : D10). Please read all instructions carefully & follow steps for easy home installation. 1 P a g e D3D Wi-Fi / GSM

More information

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0 User s Guide SUB-MA7240O-0001.OG.Solution40-111.doc Created: 6/05/03 Last Updated: 23/09/03 MA7240AO-0001 Version 1.0 2 Table Of Contents User List...6 Quick Reference..7 Features...7 Keypad User's Guide...8

More information

Quick Selection Guide Intrusion Detectors

Quick Selection Guide Intrusion Detectors Quick Selection Guide Intrusion Detectors www.boschsecurity.com Detection you can depend on Table of contents Residential and small commercial Blue Line Gen2 Series 2 Small to medium commercial Commercial

More information

GNTX FPS. VfOV. HfOV 9.2. Vision Matters CAMERAS DISPLAYS ALERTS TRANSCEIVERS ELECTRONICS

GNTX FPS. VfOV. HfOV 9.2. Vision Matters CAMERAS DISPLAYS ALERTS TRANSCEIVERS ELECTRONICS 1 8 3 2 3 4 2 4 GNTX FPS 6 3 6 2 8 8 2 6 1 VfOV 9.2 2 4 1 2 HfOV 43 1 4 2 2 2 1 6 Vision Matters CAMERAS DISPLAYS ALERTS TRANSCEIVERS ELECTRONICS Gentex Corporation Gentex is a long-time spplier of electro-optical

More information

CAMERAS DISPLAYS ALERTS TRANSCEIVERS ELECTRONICS

CAMERAS DISPLAYS ALERTS TRANSCEIVERS ELECTRONICS 1 8 3 4 2 GNTX FPS 6 3 2 4 3 6 2 8 8 2 6 1 VfOV 9.2 2 4 1 2 HfOV 43 1 4 2 2 2 1 6 Today s Featres» Tomorrow s Technology CAMERAS DISPLAYS ALERTS TRANSCEIVERS ELECTRONICS Gentex Corporation Gentex is a

More information