1 First Revision No. 1-NFPA [ Section No ] The following conditions shall be met when an interior finish material is tested using the test protocol of NFPA 286, Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth : (1) Flames shall not spread to the ceiling during the 40 kw exposure. (2) During the 160 kw exposure, the following criteria shall be met: (a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. (b) Flashover shall not occur. (3) The peak heat release rate throughout the test shall not exceed 800 kw. (4) Where limitations are desired on smoke development, the total smoke released throughout the test shall not exceed 1000 meters (3282 feet squared). Submittal Date: Tue Mar 10 10:38:57 EDT 2015 Committee Statement: The total smoke released requirement from NFPA 286 was missing. It has been added as an optional measurement when smoke limitations are desired. That is the requirement that correlates with the smoke developed index from ASTM E84 and it is included in all codes and standards that assess materials or products to NFPA 286. Response Message: Public Input No. 17-NFPA [Section No ]

2 First Revision No. 2-NFPA [ Section No ] Loose-fill insulation, other than cellulose loose-fill insulation, that cannot be mounted in the ASTM E 84 E84, Standard Test Method for Surface Burning Characteristics of Building Materials, or ANSI/UL 723, Standard for Test for Surface Burning Characteristics of Building Materials, test apparatus without a screen or other artificial support, shall have a flame spread index of 25 or less and a smoke developed index of 450 or less when tested in accordance with CAN/ULC-S102.2-M88, Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings, and Miscellaneous Materials and Assemblies. Submittal Date: Tue Mar 10 10:40:13 EDT 2015 : This simply eliminates the date, since the latest edition is dated 2010 and not Response Message: Public Input No. 20-NFPA [Section No ]

3 First Revision No. 3-NFPA [ Section No ] Cellulose loose-fill insulation that is not spray applied and that complies with the requirements of and shall be required to meet a smoke developed index not exceeding 450 when tested in accordance with ASTM E 84 CAN/ULC S102.2, Standard Test Method for Surface Burning Characteristics of Building Materials Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings, and Miscellaneous Materials and Assemblies, or ANSI/UL 723, Standard for Test for Surface Burning Characteristics of Building Materials. Submittal Date: Tue Mar 10 10:42:20 EDT 2015 Committee Statement: It has now been shown that cellulose loose-fill insulation cannot be tested appropriately using ASTM E84 (or UL 723) and needs to be tested to CAN/ULC S This change has been incorporated into other codes and standards. Moreover, ASTM E84 does not have a mandatory way of testing cellulose loose-fill insulation because it would require a metal grid that is so fine that the result is heavily affected by the metal. Response Message: Public Input No. 19-NFPA [Section No ]

4 First Revision No. 4-NFPA [ Section No ] Cellular or foam plastic materials shall be permitted if they are separated from the interior of a building and from plenums by an approved thermal barrier consisting of either of 1 2 in. (13 mm) gypsum wallboard or equivalent material and the a material that complies with the requirements of the temperature transmission fire test and of the integrity fire test in NFPA 275, and the foam plastic material also exhibits a flame spread index not exceeding 75 and a smoke developed index not exceeding 450 when tested in accordance with ASTM E 84 E84, Standard Test Method of Surface Burning Characteristics of Building Materials, or ANSI/UL 723, Standard for Test for Surface Burning Characteristics of Building Materials The thermal barrier constructed of the equivalent material shall limit the average temperature rise of the unexposed surface to not more than 250 F (121 C) after 15 minutes of fire exposure complying with the standard time-temperature curve of ASTM E 119, Standard Test Method for Fire Tests of Building Construction and Materials, or ANSI/UL 263, Fire Tests of Building Construction and Materials The thermal barrier shall remain in place for 15 minutes when tested in accordance with NFPA 286, Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth, with the acceptance criteria of Submittal Date: Tue Mar 10 10:44:11 EDT 2015 Committee Statement: The requirements in and are already included in NFPA 275, which is the standard that is used for developing and listing thermal barriers. It includes the ASTM E119 and the NFPA 286 testing. NFPA 275 also includes UL 1040, UL 1715 and FM Response Message: Public Input No. 18-NFPA [Section No ]

5 First Revision No. 11-NFPA [ Section No ] All new manufactured homes shall be protected throughout by an approved automatic sprinkler system in accordance with NFPA 13, NFPA 13R, or NFPA 13D. Submittal Date: Tue Mar 10 11:50:12 EDT 2015 Committee Statement: Response Message: NFPA 750 is not an approved automatic sprinkler system and is excluded from this list because it has not been proved to be equivalent to any of the 13 systems.

6 First Revision No. 10-NFPA [ Section No ] Where water mist systems are installed, the systems shall be designed, installed and tested in accordance with NFPA 750, Standard on Water Mist Fire Protection Systems. Submittal Date: Tue Mar 10 11:41:06 EDT 2015 : It has not been demonstrated that a 750 system is equivalent to a 13, 13D or 13R system. Response Message:

7 First Revision No. 14-NFPA [ Section No ] Wood Structural Panel. A panel manufactured from veneers; or wood strands or wafers; or a combination of veneer and wood strands or wafers bonded together with waterproof synthetic resins or other suitable bonding systems, including composite panels, oriented strand board, and plywood. [5000: ] Composite Wood Structural Panel. A structural panel that is made of layers of veneer and wood-based material. [5000: ] Oriented Strand Board (OSB) Wood Structural Panel. A mat-formed wood structural panel product composed of thin, rectangular wood strands or wafers arranged in oriented layers and bonded with waterproof adhesive. [5000: ] Plywood Wood Structural Panel. A wood structural panel comprised of plies of wood veneer arranged in cross-aligned layers. [5000: ] Submitter Full Name: Kristin Bigda Organization: National Fire Protection Assoc Submittal Date: Thu Apr 16 09:59:24 EDT 2015 : Extract update. Response Message:

8 First Revision No. 12-NFPA [ Section No ] 14.2 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA NFPA 13, Standard for the Installatiion of Sprinkler Systems, 2016 edition. NFPA 13D, Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes, edition. NFPA 13R,Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies, 2016 edition. NFPA 31, Standard for the Installation of Oil-Burning Equipment, edition. NFPA 54/ANSI Z 223.1, National Fuel Gas Code, editions. NFPA 58, Liquefied Petroleum Gas Code, edition. NFPA 70, National Electrical Code, edition. NFPA 72, National Fire Alarm and Signaling Code, edition. NFPA 90B, Standard for the Installation of Warm Air Heating and Air-Conditioning Systems, edition. NFPA 225, Model Manufactured Home Installation Standard, edition. NFPA 259, Standard Test Method for Potential Heat of Building Materials, edition. NFPA 275, Standard Method of Fire Tests for the Evaluation of Thermal Barriers Used Over Foam Plastic Insulation, 2017 edition. NFPA 286, Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth, edition. NFPA 720, Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment, edition. NFPA 750, Standard on Water Mist Fire Protection Systems, 2010 edition. Submittal Date: Tue Mar 10 14:22:48 EDT 2015 Committee Statement: Response Message: NFPA 750 was removed from Chapter 5. A reference to NFPA 275 was added during the First Draft.

9 First Revision No. 6-NFPA [ Section No ] ASHRAE Publications. ASHRAE, Inc., 1791 Tullie Circle, N.E. NE, Atlanta, GA ASHRAE Handbook of-fundamentals Handbook Fundamentals, Submittal Date: Tue Mar 10 10:59:48 EDT 2015 : The outdated reference to the ASHRAE Handbook of Fundamentals was updated. Response Message: Public Input No. 9-NFPA [Section No ]

10 0 First Revision No. 7-NFPA [ Section No ]

11 ASTM Publications.

12 2 ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA ASTM A 53 A53/ 53M, Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless, ASTM A 74 A74, Standard Specification for Cast Iron Soil Pipe and Fittings, a. ASTM A 539 A539, Standard Specification for Electric-Resistance-Welded Coiled Steel Tubing for Gas and Fuel Oil Lines, ASTM B 42 B42, Standard Specification for Seamless Copper Pipe, Standard Sizes, ASTM B 43 B43, Standard Specification for Seamless Red Brass Pipe, Standard Sizes, ASTM B 88 B88, Standard Specification for Seamless Copper Water Tube, ASTM B 251 B251, Standard Specification for General Requirements for Wrought Seamless Copper and Copper-Alloy Tube, ASTM B 280 B280, Standard Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service, ASTM B306, Standard Specification for Copper Drainage Tube (DWV), ASTM C 36 C36/ 36M, Standard Specification for Gypsum Wallboard, 2003 (withdrawn, replaced by C1396/C1396M). ASTM C 36 36M, Standard Specification for Gypsum Wallboard, 2003 (withdrawn, replaced by C1396/C1396M). ASTM C 564 C564, Standard Specification for Rubber Gaskets for Cast Iron Soil Pipe and Fittings, ASTM C 920 C920, Standard Specification for Elastomeric Joint Sealants, a. ASTM C1396/C1396M, Standard Specification for Gypsum Board, 2014a. ASTM D 781 D781, Standard Test Methods for Puncture and Stiffness of Paperboard, and Corrugated and Solid Fiberboard, 1968 (1973) (withdrawn 1984 without replacement). ASTM D 2235 D2235, Standard Specification for Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe and Fittings, 2004 ( 2011 ). ASTM D 2239 D2239, Polyethylene (PE) Plastic Pipe, (SDR-PR) Based on Controlled Inside Diameter, a. ASTM D 2564 D2564, Standard Specification for Solvent Cement for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems, ASTM D 2609 D2609, Plastic Insert Fittings for Polyethylene (PE) Plastic Pipe, 2002 ( 2008). ASTM D 2661 D2661, Standard Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe and Fittings, ASTM D 2665 D2665, Standard Specification for Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings, ASTM D 2846 D2846/D2846M, Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot- and Cold-Water Distribution Systems, b e1. ASTM D 3309 D3309, Standard Specification for Polybutylene (PB) Plastic Hot- and Cold-Water Distribution Systems, a (2002) (withdrawn 2010, without replacement). ASTM D 3311 D3311, Standard Specification for Drain, Waste, and Vent (DWV) Plastic Fittings, ASTM D 3953 D3953, Standard Specification for Strapping, Flat Steel, and Seals, 2007a ASTM D 4442 D4442, Standard Test Methods for Direct Moisture Content Measurement of Wood and Wood-Base Materials, ASTM D 4444 D4444, Standard Test Methods for Use and Calibration of Hand-Held Moisture Meters, ASTM D 4635 D4635, Specification for Low-Density Polyethylene Films for General Use and Packaging Applications, 2008a.

13 3 ASTM E 84 E84, Standard Test Method for Surface Burning Characteristics of Building Materials, ASTM E 96 E96 /E96M, Standard Test Methods for Water Vapor Transmission of Materials, ASTM E 119 E119, Standard Test Method for Fire Tests of Building Construction and Materials, ASTM E136, Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 C, ASTM E 773 E773, Standard Test Method for Accelerated Weathering of Sealed Insulating Glass Units, 2001 (withdrawn 2010 without replacement). ASTM E 162 E162, Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source, 2011a ASTM E 773 E773, Standard Test Method for Accelerated Weathering of Sealed Insulating Glass Units, 2001 (withdrawn 2010 without replacement). ASTM E 774 E774, Standard Specification for the Classification of the Durability of Sealed Insulating Glass Units, 1997 (withdrawn 2006 without replacement). ASTM E 970 E970, Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source, ASTM E 1333 E1333, Standard Test Method for Determining Formaldehyde Levels from Wood Products Under Defined Test Conditions Using a Large Chamber, 1996, revised ASTM E 2652 E2652, Standard Test Method for Behavior of Materials in a Tube Furnace with a Cone-shaped Airflow Stabilizer, at 750 C, 2009a ASTM F 438 F438, Socket-Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Sch. 40, ASTM F 439 F439, Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Sch. 80, ASTM F 441 F441/F441M, Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Sch. 40 and 80, e1. ASTM F493, Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe and Fittings, ASTM F 628 F628, Standard Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe with a Cellular Core, 2008 el 2012 e1. ASTM F 628 F628, Standard Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe with a Cellular Core, 2008 el 2012 e1. ASTM F 876 F876, Standard Specification for Crosslinked Polyethylene (PEX) Tubing, a. ASTM F 877 F877, Standard Specification for Crosslinked Polyethylene (PEX) Plastic Hot- and Cold-Water Distribution Systems, a. ASTM F 986 F986, Standard Specification for Suction Strainer Boxes, 1986, revised 1997 (2014). ASTM F 1281 F1281, Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene (PEX-AL-PEX) Pressure Pipe, ASTM F 1282 F1282, Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe, ASTM F 1807 F1807, Metal Insert Fittings Utilizing Copper Crimp Ring for SDR 9 Crosslinked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing, 2011 el ASTM F 1960 F1960, Cold Expansion Fittings with PEX Reinforcing Rings for Use with Crosslinked Polyethylene (PEX) Tubing, ASTM F 1961 F1961, Metal Mechanical Cold Flare Compression Fittings with Disc Springs for Crosslinked Polyethylene (PEX) Tubing, ASTM F 1974 F1974, Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene Composite Pressure Pipe, ASTM F 2080 F2080, Cold-Expansion Fittings with Metal Compression Sleeves for Cross-Linked

14 4 Polyethylene (PEX) Pipe, e1. Submittal Date: Tue Mar 10 11:02:28 EDT 2015 : Update to standards editions. Response Message: Public Input No. 16-NFPA [Section No ]

15 5 First Revision No. 13-NFPA [ Section No ] 14.4 References for Extracts in Mandatory Sections. NFPA 70, National Electrical Code, edition. NFPA 72, National Fire Alarm and Signaling Code, edition. NFPA 5000, Building Construction and Safety Code, edition. Submitter Full Name: Sonia Barbosa Submittal Date: Thu Apr 02 11:31:51 EDT 2015 : Updating edition years. Response Message:

16 6 First Revision No. 8-NFPA [ Section No. A ] A A cooling load (heat gain) calculation is required to determine the required capacity of equipment to cool a home efficiently and economically. The cooling load is dependent on the orientation, location, and structure of the home. Central air conditioners operate most efficiently and provide the greatest comfort when their capacity closely approximates the calculated cooling load. Each home s air conditioner should be sized in accordance with Chapter 27 of the 2004 ASHRAE Handbook of Fundamentals Handbook Fundamentals, once the location and orientation are known. Submittal Date: Tue Mar 10 11:03:22 EDT 2015 Committee Statement: Response Message: The references to the ASHRAE Handbook of Fundamentals are outdated. This proposal seeks to update those references. Public Input No. 10-NFPA [Section No. A ]

17 First Revision No. 9-NFPA [ Chapter D ] Annex D Informational References D.1 Referenced Publications. The following documents or portions thereof are referenced within this standard for informational purposes only and are thus not part of the requirements of this document unless also listed in Chapter 14. D.1.1 NFPA Publications. (Reserved) D.1.2 Other Publications. D ASHRAE Publication. American Society of Heating, Refrigeration and Air Conditioning Engineers, 1791 Tullie Circle, N.E. NE, Atlanta, GA ASHRAE Handbook of Fundamentals Handbook Fundamentals, D ASTM Publication. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA ASTM E 903 E903, Standard Test Method for Solar Absorptance, Reflectance, and Transmittance of Materials Using Integrating Spheres, 1996, reinstated D FEMA Publications. Federal Emergency Management Agency, 500 C Street SW, Washington, DC FEMA 320 P-320, Taking Shelter from the Storm: Building a Safe Room for Your Home or Small Business, FEMA 361 P-361, Design and Construction Guidance for Community Safe Rooms, D ICC Publication. International Code Council, 5203 Leesburg Pike, Suite 600, Falls Church, Virginia ICC 500, Standard for the Design and Construction of Storm Shelters, D.2 Informational References. (Reserved) D.3 References for Extracts in Informational Sections. NFPA 5000, Building Construction and Safety Code, edition. Submittal Date: Tue Mar 10 11:06:09 EDT 2015 : Referenced current editions. Response Message: Public Input No. 14-NFPA [Chapter D] Public Input No. 11-NFPA [Section No. D.1.2.1] 7

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement Second Revision No. 1-NFPA 90A-2016 [ Section No. 2.3.2 ] 2.3.2 ASTM International Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM C411, Standard

More information

First Revision No. 6-NFPA [ Section No. 2.2 ]

First Revision No. 6-NFPA [ Section No. 2.2 ] Page 1 of 18 First Revision No. 6-NFPA 555-2014 [ Section No. 2.2 ] 2.2 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471. NFPA 12, Standard on Carbon

More information

CHAPTER 15 REFERENCED STANDARDS SECTION MC 1502 STANDARDS. Number Title section number Manual D 95 Residential Duct Systems

CHAPTER 15 REFERENCED STANDARDS SECTION MC 1502 STANDARDS. Number Title section number Manual D 95 Residential Duct Systems CHAPTER 15 REFERENCED STANDARDS SECTION MC 1501 GENERAL 1501.1 General. This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the

More information

Public Comment No. 1-NFPA [ Section No ]

Public Comment No. 1-NFPA [ Section No ] Page 1 of 7 Public Comment No. 1-NFPA 556-2014 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA, 19428-2959. ASTM D2859, Standard

More information

CHAPTER 15 REFERENCED STANDARDS. Air-Conditioning, Heating and Refrigeration Institute 4100 North Fairfax Drive, Suite 200 Arlington, VA 22203

CHAPTER 15 REFERENCED STANDARDS. Air-Conditioning, Heating and Refrigeration Institute 4100 North Fairfax Drive, Suite 200 Arlington, VA 22203 CHAPTER 15 REFERENCED STANDARDS This chapter lists the standards that are d in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard

More information

Change all instances of "flame resistant (hypobaric)" to "Limited-Combustible (material)" in all instances in the document.

Change all instances of flame resistant (hypobaric) to Limited-Combustible (material) in all instances in the document. 1 of 9 10/21/2015 1:22 PM First Revision No. 3-NFPA 99B-2015 [ Global Input ] Change all instances of "flame resistant (hypobaric)" to "Limited-Combustible (material)" in all instances in the document.

More information

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM 1 of 11 1/18/2016 5:43 PM First Revision No. 2-NFPA 51-2015 [ Global Input ] Throughout standard remove references to the following and replace with the following: (1) CGA C-7 Guide to Precautionary Labelling

More information

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] 1.3 Application. 1.3.1 This standard shall apply to all systems for the movement of environmental air in structures that serve the following, except

More information

CHAPTER 15 REFERENCED STANDARDS. Air-Conditioning, Heating and Refrigeration Institute 4100 North Fairfax Drive, Suite 200 Arlington, VA 22203

CHAPTER 15 REFERENCED STANDARDS. Air-Conditioning, Heating and Refrigeration Institute 4100 North Fairfax Drive, Suite 200 Arlington, VA 22203 CHAPTER 15 REFERENCED STANDARDS This chapter lists the standards that are d in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard

More information

Second Revision No. 3-NFPA [ Section No. 2.3 ]

Second Revision No. 3-NFPA [ Section No. 2.3 ] Second Revision No. 3-NFPA 804-2014 [ Section No. 2.3 ] 2.3 Other Publications. 2.3.1 ASME Publications. American Society of Mechanical Engineers, Three Park Avenue, New York, NY 10016-5990. ASME Boiler

More information

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item Public Comment No. 23-NFPA 96-2015 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM E84, Standard Test Method

More information

Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ]

Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ] Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard and shall be considered

More information

Read Only Copy Not For Distribution. Chapter 19. Referenced Standards 19.1 REFERENCED STANDARDS 19.2 STANDARDS ORGANIZATIONS

Read Only Copy Not For Distribution. Chapter 19. Referenced Standards 19.1 REFERENCED STANDARDS 19.2 STANDARDS ORGANIZATIONS 19.1 REFERENCED STANDARDS Referenced Standards Chapter 19 Table 19.1 lists the standards that are referenced within the requirements of this Code. Table 19.1 shows the designation number of the standard,

More information

Public Input No. 1-NFPA 99B-2015 [ Section No. 2.3 ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

Public Input No. 1-NFPA 99B-2015 [ Section No. 2.3 ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document 1 of 19 10/21/2015 1:20 PM Public Input No. 1-NFPA 99B-2015 [ Section No. 2.3 ] 2.3 Other Publications. 2.3.1 ASME Publications. American Society of Mechanical Engineers, Three ASME International, Two

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Merchant Vessels

More information

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved. Public Input No. 1-NFPA 557-2012 [ New Section after 1.5.3 ] 1.6 Approved Qualifications The design shall be prepared by a person with qualifications acceptable to the AHJ. The term designer is used in

More information

6/9/ :58 PM. First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement

6/9/ :58 PM. First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement First Revision No. 1-NFPA 259-2016 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM D5865, Standard Test Method

More information

Committee Input No. 5-NFPA [ Chapter 14 ]

Committee Input No. 5-NFPA [ Chapter 14 ] http://submittalsnfpaorg/terraviewweb/contentfetcher?commentpara Committee Input No 5-NFPA 501-2015 [ Chapter 14 ] Chapter 14 Referenced Referenced Publications 14 1 General 1 General The documents or

More information

Standard Compared 2012 Changes of the International Building Code and National Fire Protection Association- 101

Standard Compared 2012 Changes of the International Building Code and National Fire Protection Association- 101 Standard Compared 2012 Changes of the International Building Code and National Fire Protection Association- 101 For the Florida Building Commission And the Fire Code Advisory Council Introduction The scope

More information

CHAPTER 15 REFERENCED STANDARDS

CHAPTER 15 REFERENCED STANDARDS CHAPTER 15 REFERENCED STANDARDS This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the

More information

Throughout standard remove references to the following and replace with the following:

Throughout standard remove references to the following and replace with the following: of 35 12/3/2015 7:13 AM Public Input No. 1-NFPA 90A-2015 [ Global Input ] Throughout standard remove references to the following and replace with the following: (1) ANSI/UL and replace with UL. (2) ANSI/ASHRAE

More information

Public Comment No. 16-NFPA 13D-2014 [ Section No ]

Public Comment No. 16-NFPA 13D-2014 [ Section No ] of 52 9/22/2014 9:20 AM Public Comment No. 16-NFPA 13D-2014 [ Section No. 2.3.3 ] 2.3.3 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM

More information

1/8/ :02 AM. Public Input No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

1/8/ :02 AM. Public Input No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input Public Input No. 2-NFPA 259-2015 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM D 5865, Standard Test Method

More information

2016 Uniform Solar Energy & Hydronics Code Technical Committee Meeting IAPMO World Headquarters, Ontario, CA October 26, 2016 AGENDA

2016 Uniform Solar Energy & Hydronics Code Technical Committee Meeting IAPMO World Headquarters, Ontario, CA October 26, 2016 AGENDA 2016 Uniform Solar Energy & Hydronics Code Technical Committee Meeting IAPMO World Headquarters, Ontario, CA October 26, 2016 AGENDA I. Call to Order II. Chairman Comments III. Announcements IV. Self Introductions

More information

First Revision No. 1-NFPA [ Chapter 2 ]

First Revision No. 1-NFPA [ Chapter 2 ] First Revision No. 1-NFPA 499-2014 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this recommended practice

More information

Adobe Connect - Invitation to NFPA 385 Second Draft Web Conference

Adobe Connect - Invitation to NFPA 385 Second Draft Web Conference Matthews, Diane Subject: Location: Start: End: Show Time As: Recurrence: Meeting Status: Organizer: Required Attendees: Adobe Connect - Invitation to NFPA 385 Second Draft Web Conference http://nfpa.adobeconnect.com/rpbmeet/

More information

Page 1 of 13 Second Revision No. 1-NFPA 326-2014 [ Section No. 2.3.1 ] 2.3.1 ACGIH Publications. American Conference of Governmental Industrial Hygienists, 1330 Kemper Meadow Drive, Cincinnati, OH 45240-1634.

More information

1 of /3/ :03 PM. Public Input No. 1-NFPA 13D-2015 [ Chapter 2 ]

1 of /3/ :03 PM. Public Input No. 1-NFPA 13D-2015 [ Chapter 2 ] 1 of 129 11/3/2016 12:03 PM Public Input No. 1-NFPA 13D-2015 [ Chapter 2 ] 2 of 129 11/3/2016 12:03 PM American Society of Mechanical Engineers Chapter 2 Referenced Publications 2.1 General. The documents

More information

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement 1 of 7 3/4/2016 12:02 PM Second Revision No. 5-NFPA 56-2016 [ Section No. 1.1.2 ] 1.1.2 Nonapplication of Standard. This standard shall not apply to the following items: (1)* Piping systems covered by

More information

12/21/2015 National Fire Protection Association Report

12/21/2015 National Fire Protection Association Report http://submittals.nfpa.org/terraviewweb/viewerpage.jsp?id=232 2012.ditamap&toc=false&draft=true 1/9 Public Comment No. 1 NFPA 232 2015 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents

More information

Review of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings

Review of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings Review of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings Reprinted with permission from NFPA 13D Installation of Sprinkler Systems in One- and two-family Dwellings and Manufactured

More information

CHAPTER 6 [CE] REFERENCED STANDARDS

CHAPTER 6 [CE] REFERENCED STANDARDS CHAPTER 6 [CE] REFERENCED STANDARDS User note: About this chapter: Chapter 6 lists the full title, edition year and address of the promulgator for all standards that are referenced in the code. The section

More information

First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes

First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] 4.3.11.5.5 Materials within a raised floor plenum exposed to the airflow shall be (a) noncombustible or (b) exhibit a maximum flame spread index of 25

More information

Location of Requirements Listed Category I appliances Type B gas vent 12.7 Listed appliances equipped with. Chimney Single wall metal pipe 12.

Location of Requirements Listed Category I appliances Type B gas vent 12.7 Listed appliances equipped with. Chimney Single wall metal pipe 12. 2/18/2016 National Fire Protection Association Report Committee Input No. 70 NFPA 54 2015 [ Section No. 12.5 ] This was a First Revision that failed ballot. 12.5 Type of Venting System to Be Used. 12.5.1

More information

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169 7471 Phone: 617 770 3000 Fax: 617 770 0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Furnishings

More information

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016)

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Solvent Extraction Plants

More information

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification Public Input No. 1-NFPA 36-2013 [ Global Input ] Revise the document to eliminate the use of "Exception" text. The use of "Exception" text is inconsistent with the Manual of Style. Exception text should

More information

Reference to the Smoke Damage Index (SDI) is needed as it is part of the test method.

Reference to the Smoke Damage Index (SDI) is needed as it is part of the test method. Public Input No. 4-NFPA 287-2014 [ Section No. 1.2.3.2 ] 1.2.3.2 Indices resulting from the test methods include critical heat flux (CHF), thermal response parameter (TRP), fire propagation index (FPI),

More information

TABLE OF CONTENTS. Tentative Agenda. Tentative Order of Discussion. A2L Task Group Report III. Uniform Mechanical Code Change Public Comments

TABLE OF CONTENTS. Tentative Agenda. Tentative Order of Discussion. A2L Task Group Report III. Uniform Mechanical Code Change Public Comments TABLE OF CONTENTS I Tentative Agenda II Tentative Order of Discussion III A2L Task Group Report IV Uniform Mechanical Code Change Public Comments 2017 Uniform Mechanical Code Technical Committee Meetings

More information

Revise the metric values throughout the standard to follow the soft conversions provided by the metric task group

Revise the metric values throughout the standard to follow the soft conversions provided by the metric task group of 36 9/22/2014 9:37 AM Second Revision No. 14-NFPA 13D-2014 [ Global Comment ] Revise the metric values throughout the standard to follow the soft conversions provided by the metric task group Supplemental

More information

CHAPTER 6 REFERENCED STANDARDS. American Architectural Manufacturers Association 1827 Walden Office Square Suite 550 Schaumburg, IL

CHAPTER 6 REFERENCED STANDARDS. American Architectural Manufacturers Association 1827 Walden Office Square Suite 550 Schaumburg, IL CHAPTER 6 REFERENCED STANDARDS This chapter lists the standards that are d in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard

More information

Report on Public Input June 2014 NFPA 101

Report on Public Input June 2014 NFPA 101 101 PI# 115 SAF-FUR (10.2.1.2) 10.2.1.2 Materials applied directly to the surface of walls and ceilings in a total thickness of less than 1 / 28 in. (0.9 mm) shall not be considered interior finish and

More information

First Revision No. 7-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

First Revision No. 7-NFPA [ Global Input ] Submitter Information Verification. Committee Statement of 29 6/9/2016 1:42 PM First Revision No. 7-NFPA 289-2016 [ Global Input ] Add comman between "reconstruction or research" throughout the document as follows: "reconstruction, or research" Submittal Date:

More information

PRODUCT SPECIFICATION DRAWING Hydroflame Pro Series Sleeves

PRODUCT SPECIFICATION DRAWING Hydroflame Pro Series Sleeves Cap & Locator Whiskers PRODUCT SPECIFICATION DRAWING Hydroflame Pro Series Sleeves CD Plate (optional) See Dim *"C" (Telescoping) Safety Cap & Locator Whiskers Included (Shown with optional CD Plate) (OSHA

More information

First Revision No. 20-NFPA [ Section No ]

First Revision No. 20-NFPA [ Section No ] of 25 7/15/2015 8:30 AM First Revision No. 20-NFPA 56-2015 [ Section No. 1.1.2 ] 1.1.2 Nonapplication of Standard. This standard shall not apply to the following items: (1)* Piping systems covered by NFPA

More information

STANDARDS TASK GROUP REPORT

STANDARDS TASK GROUP REPORT STANDARDS TASK GROUP REPORT THE SCOPE OF THE STANDARDS TASK GROUP INCLUDES ADDING CROSS- REFERENCES TO TABLE 14-1 AND RECOMMEND WHERE SUCH REFERENCES ARE APPLICABLE TO THE REFERENCED STANDARDS AND TO UPDATE

More information

First Revision No. 15-NFPA [ Chapter 2 ]

First Revision No. 15-NFPA [ Chapter 2 ] Page 1 of 28 First Revision No. 15-NFPA 91-2013 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard

More information

CHAPTER 5 REFERENCED STANDARDS. American Architectural Manufacturers Association 1827 Walden Office Square Suite 550 Schaumburg, IL

CHAPTER 5 REFERENCED STANDARDS. American Architectural Manufacturers Association 1827 Walden Office Square Suite 550 Schaumburg, IL CHAPTER 5 REFERENCED STANDARDS This chapter lists the standards that are d in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard

More information

Internal Use Only INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR

Internal Use Only INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR ELECTRICAL OR HIGH-DENSITY MAGNETIC ANTI-SCALE OR WATER CONDITIONING APPLIANCE IGC 91-2009 1. PURPOSE 1.1 The purpose

More information

MEMORANDUM. NFPA 51 First Draft Technical Committee FINAL Ballot Results (A2017 Cycle)

MEMORANDUM. NFPA 51 First Draft Technical Committee FINAL Ballot Results (A2017 Cycle) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM TO: FROM: Technical Committee on Industrial and Medical Gases

More information

CHAPTER 17 STANDARDS STANDARDS Broadway, New York, NY 10018,

CHAPTER 17 STANDARDS STANDARDS Broadway, New York, NY 10018, STANDARDS Chapter 17, Part II CHAPTER 17 STANDARDS 1701.0 Scope Part I of this chapter covers standards that are hereby declared to be part of this code. Part II of this chapter lists standards which relate

More information

CUMULATIVE ANALYSIS OF UNIFORM MECHANICAL CODE CHANGES to 2003

CUMULATIVE ANALYSIS OF UNIFORM MECHANICAL CODE CHANGES to 2003 CUMULATIVE ANALYSIS OF UNIFORM MECHANICAL CODE CHANGES 2000 to 2003 The following pages contain comments regarding the changes to the 2000 edition of the UNIFORM MECHANICAL CODE (UMC ) that were made to

More information

Second Revision No. 1 NFPA [ Chapter 2 ]

Second Revision No. 1 NFPA [ Chapter 2 ] Second Revision No. 1 NFPA 232 2015 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard and shall be

More information

Committee Input No. 60-NFPA [ Sections , ]

Committee Input No. 60-NFPA [ Sections , ] Page 1 of 15 Committee Input No. 60-NFPA 34-2013 [ Sections 3.3.7.1, 3.3.7.2 ] Sections 3.3.7.1, 3.3.7.2 3.3.7.1 Combustible Liquid. A Any liquid that has a closed-cup flash point at or above 100 F (37.8

More information

NZS 4517:2010. New Zealand Standard. Fire sprinkler systems for houses. Superseding NZS 4517:2002 NZS 4517:2010

NZS 4517:2010. New Zealand Standard. Fire sprinkler systems for houses. Superseding NZS 4517:2002 NZS 4517:2010 New Zealand Standard Fire sprinkler systems for houses Superseding NZS 4517:2002 NZS 4517:2010 NZS 4517:2010 COMMITTEE REPRESENTATION This Standard was prepared under the supervision of the P 4517 Committee,

More information

Second Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 6/23/ :34 AM

Second Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 6/23/ :34 AM of 56 6/23/2016 11:34 AM Second Revision No. 1-NFPA 96-2016 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM

More information

Page 1 of 19 Committee Input No. 14-NFPA 33-2013 [ Global Input ] Type your content here... Supplemental Information File Name IndoorDraftforCI.docx Description This committee input would be added to new

More information

NFPA Technical Meeting (Tech Session) June 24-25, 2015 Agenda*

NFPA Technical Meeting (Tech Session) June 24-25, 2015 Agenda* NFPA Technical Meeting (Tech Session) June 24-25, 2015 Agenda* NFPA Standards presented for Action Wednesday, June 24, 2015 starting @ 2:00pm: NFPA 33, Standard for Spray Application Using Flammable or

More information

WORKING DRAFT OF COMMITTEE MEETING OUTPUT

WORKING DRAFT OF COMMITTEE MEETING OUTPUT WORKING DRAFT OF COMMITTEE MEETING OUTPUT CONTENT NOT FINAL SUBJECT TO REVISION PRIOR TO LETTER BALLOT AND PUBLICATION OF SECOND DRAFT REPORT Document: NFPA 221 Revision Cycle: A2014 Meeting Date: 5/20/2013

More information

CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS PRE-PRINT. STANDARD NumBER STANDARD TiTLE APPLiCATioN

CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS PRE-PRINT. STANDARD NumBER STANDARD TiTLE APPLiCATioN CHAPTER 14 STANDARDS Note: Referenced sections will be updated before publishing. 1401.0 General. 1401.1 Standards. The standards listed in Table 1401.1 are intended for use in the design, testing, and

More information

Public Comment No. 10-NFPA [ Chapter 2 ]

Public Comment No. 10-NFPA [ Chapter 2 ] 1 of 46 12/9/2015 8:16 AM Public Comment No. 10-NFPA 130-2015 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within

More information

First Revision No. 82-NFPA [ Detail ] Submitter Information Verification Submitter Full Name: Organization:

First Revision No. 82-NFPA [ Detail ] Submitter Information Verification Submitter Full Name: Organization: of 176 1/25/2016 3:32 PM First Revision No. 82-NFPA 54-2015 [ Detail ] Title of 7.1: Installation of Underground Piping. Underground Title of 7.2: Installation of Aboveground Piping. Submittal Date: Thu

More information

CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS STANDARD NUMBER STANDARD TITLE APPLICATION

CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS STANDARD NUMBER STANDARD TITLE APPLICATION CHAPTER 14 STANDARDS 1401.0 General. 1401.1 Standards. The standards listed in Table 1401.1 are intended for use in the design, testing, and installation of materials, devices, appliances, and equipment

More information

Report on First Revision June 2014 NFPA 101

Report on First Revision June 2014 NFPA 101 101 FR500 SAF-FUR (10.2.1.2 and 10.2.1.3) Recommendation: 10.2.1.2 The provisions of Section 10.2.1.1 shall not apply to mmaterials having a total thickness of less than 1/28 in (0.9 mm) that are applied

More information

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical on Laser Fire Protection Kimberly

More information

Public Input No. 3-NFPA [ Chapter 2 ]

Public Input No. 3-NFPA [ Chapter 2 ] Public Input No. 3-NFPA 655-2014 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard and shall be considered

More information

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M To: From: NFPA Technical Committee on Helicopter Facilities

More information

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content Based on the 2018 International Fire Code, (IFC ) The International Fire Code (IFC ), establishes minimum regulations for fire safety. This handout will identify important changes in the IFC from 2015

More information

DUCT SYSTEMS CHAPTER 6

DUCT SYSTEMS CHAPTER 6 SECTION 601 GENERAL 601.1 Scope. Duct systems used for the movement of air in air-conditioning, heating, ventilating and exhaust systems shall conform to the provisions of this chapter except as otherwise

More information

Public Comment No. 32-NFPA 90A-2016 [ Section No ] Statement of Problem and Substantiation for Public Comment

Public Comment No. 32-NFPA 90A-2016 [ Section No ] Statement of Problem and Substantiation for Public Comment of 53 11/9/2016 9:07 AM Public Comment No. 32-NFPA 90A-2016 [ Section No. 2.3.2 ] 2.3.2 ASTM International Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA

More information

Page 1 of 15 Second Revision No. 8-NFPA 82-2013 [ Section No. 2.2 ] 2.2 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471. NFPA 13, Standard for the Installation

More information

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM First Revision No. 1-NFPA 1403-2015 [ Section No. 1.2.1 ] 1.2.1 The purpose of this standard shall be to provide a process for conducting live fire training evolutions to ensure that they are conducted

More information

DUCT SYSTEMS CHAPTER 6

DUCT SYSTEMS CHAPTER 6 CHAPTER 6 DUCT SYSTEMS SECTION 601 GENERAL 601.1 Scope. Duct systems used for the movement of air in air-conditioning, heating, ventilating and exhaust systems shall conform to the provisions of this chapter

More information

This standard shall prescribe provisions based on minimum requirements for safety to life and property.

This standard shall prescribe provisions based on minimum requirements for safety to life and property. NFPA STANDARDS DEVELOPMENT SITE FIRST DRAFT REPORT Closing Date: February 22, 2013 NOTE: All Public Comment must be received by 5:00 pm EST/EDST on the published Closing Date. NFPA 90B, Standard for the

More information

Public Comment No. 2-NFPA [ Section No ]

Public Comment No. 2-NFPA [ Section No ] Page 1 of 13 Public Comment No. 2-NFPA 703-2013 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, P.O. Box C700, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959. ASTM D 2898, Standard

More information

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM of 25 7/30/2015 1:35 PM First Revision No. 49-NFPA 17A-2015 [ Detail ] Make the following change to 5.2.1.10.2: 5.2.1.10.2* The manual actuation device shall clearly identify the hazard protected and provide

More information

M E M O R A N D U M. NFPA Technical Committee on Alternative Approaches to Life Safety. SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle)

M E M O R A N D U M. NFPA Technical Committee on Alternative Approaches to Life Safety. SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle) M E M O R A N D U M TO: FROM: NFPA Technical Committee on Alternative Approaches to Life Safety Linda MacKay DATE: December 28, 2010 SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle) The ROP letter

More information

TABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7

TABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7 TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION..............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

The following preprint is based on the First Revision Draft of the 2018 edition of NFPA 54/Z223.1.

The following preprint is based on the First Revision Draft of the 2018 edition of NFPA 54/Z223.1. Copyright 2016 by American Gas Association and the National Fire Protection Association, All Rights Reserved BSR Z223.1 20xx NFPA 54 20xx National Fuel Gas Code 2018 Edition NOTE: This preprint of the

More information

Safety Code Users. Fire Tests for Life SUPPLEMENT 3. Marcelo M. Hirschler FIRE PROPERTIES

Safety Code Users. Fire Tests for Life SUPPLEMENT 3. Marcelo M. Hirschler FIRE PROPERTIES SUPPLEMENT 3 Fire Tests for Life Safety Code Users Marcelo M. Hirschler Editor s Note: This supplement is written to assist the reader in determining the applicability of fire test standards, especially

More information

Analysis of Changes for the 6 th Edition (2017) Florida Codes

Analysis of Changes for the 6 th Edition (2017) Florida Codes Analysis of Changes for the 6 th Edition (2017) Florida Codes Changes to the Florida Building Code, Mechanical This Analysis of Changes for the 6 th Edition (2017) of the Florida Codes is intended to provide

More information

First Revision No. 36-NFPA [ Section No. 1.1 [Excluding any Sub-Sections] ]

First Revision No. 36-NFPA [ Section No. 1.1 [Excluding any Sub-Sections] ] of 71 6/11/2014 8:20 AM First Revision No. 36-NFPA 76-2014 [ Section No. 1.1 [Excluding any Sub-Sections] ] This standard provides requirements for fire protection of telecommunications facilities where

More information

9/23/ :47 AM. Second Revision No NFPA [ New Section after ] Submitter Information Verification. Committee Statement

9/23/ :47 AM. Second Revision No NFPA [ New Section after ] Submitter Information Verification. Committee Statement Second Revision No. 5501-NFPA 5000-2016 [ New Section after 29.2.1.2 ] 29.2.1.3 Bathtubs, bathtub-shower combinations, and nonemergency showers shall be provided with grab bars in accordance with the provisions

More information

Second Revision No. 1-NFPA [ Section No. 2.2 ] Submitter Information Verification. Committee Statement

Second Revision No. 1-NFPA [ Section No. 2.2 ] Submitter Information Verification. Committee Statement Second Revision No. 1-NFPA 1410-2014 [ Section No. 2.2 ] 2.2 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471. NFPA 1500, Standard on Fire Department

More information

Report on First Revision November 2013 NFPA 750

Report on First Revision November 2013 NFPA 750 750 FR1 (Chapter 2) Recommendation: Update the following references: Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard

More information

Public Comment No. 20-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

Public Comment No. 20-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item of 27 9/2/2014 9:27 AM Public Comment No. 20-NFPA 24-2014 [ Section No. 2.3.2 ] 2.3.2 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM

More information

Remove the "Exception" text to be consistent with direction provided in the MOS.

Remove the Exception text to be consistent with direction provided in the MOS. of 37 1/11/2017 7:38 AM Public Input No. 9-NFPA 88A-2015 [ Global Input ] Remove the "Exception" text to be consistent with direction provided in the MOS. The current language in 88A has numerous section

More information

Technical Committee on Record Protection (REA-AAA)

Technical Committee on Record Protection (REA-AAA) Technical Committee on Record Protection (REA-AAA) DATE: September 8, 2015 TO: FROM: M E M O R A N D U M Principal and Alternate Members of the Technical Committee on Record Protection (REA-AAA) Audrey

More information

The distances in shall be reduced to 130 ft (39.7 m) when manual dry standpipes are installed in open parking garages.

The distances in shall be reduced to 130 ft (39.7 m) when manual dry standpipes are installed in open parking garages. of 123 6/10/2014 9:07 AM First Revision No. 117-NFPA 14-2014 [ Global Input ] 7.3.2.7.5 The distances in 7.3.2.2 shall be reduced to 130 ft (39.7 m) when manual dry standpipes are installed in open parking

More information

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating. SECTION 15890 DUCTWORK PART 1 - GENERAL 1.1 SECTION INCLUDES A. Metal ductwork. B. Duct cleaning. 1.2 RELATED SECTIONS A. Section 09900 - Painting: Weld priming, weather resistant, paint or coating. B.

More information

Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification Public Input No. 4-NFPA 496-2014 [ Section No. 5.2.2 ] 5.2.2 Where When the enclosure has been opened or if the protective gas supply has failed to maintain the required positive pressure, the enclosure

More information

Public Comment No. 13-NFPA [ Section No ]

Public Comment No. 13-NFPA [ Section No ] Public Comment No. 13-NFPA 30-2013 [ Section No. 2.3.3 ] 2.3.3 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM A 395/A395M, Standard

More information

Fire Test Methods ASTM NFPA UL ISO IEC

Fire Test Methods ASTM NFPA UL ISO IEC Fire Test Methods ASTM NFPA UL ISO IEC D2859 (Standard Test Method for Ignition Characteristics of Finished Textile Floor Covering Materials) E84 (Standard Test Method for Surface Burning Characteristics

More information

IAS Accreditation Number Applied Research Laboratories of South Florida, LLC 5371 Northwest 161st Street Miami, Florida 33014

IAS Accreditation Number Applied Research Laboratories of South Florida, LLC 5371 Northwest 161st Street Miami, Florida 33014 IAS Accreditation Number Company Name Address Contact Name TL-222 of South Florida, LLC 5371 Northwest 161st Street Miami, Florida 33014 John Lewczak Director of Quality Assurance Telephone (305) 624-4800

More information

CHAPTER 14 MANDATORY REFERENCED STANDARDS TABLE 14-1

CHAPTER 14 MANDATORY REFERENCED STANDARDS TABLE 14-1 CHAPTER 14 MANDATORY REFERENCED STANDARDS AHAM DW-1-92 Household Electric Dishwashers Appliances AHAM DW-2PR-92 Plumbing Requirements for Household Dishwashers Appliances AHAM FWD-1-92 Food Waste Disposers

More information

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5 INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5 5 Tech Notes TESTING PROTOCOL Fire Retardant Gel Coats Issue Date: 4/22/2010 Document ID: TN-TS-05A 2010 Interplastic Corporation Testing Protocol

More information

Public Input No. 16-NFPA [ Section No ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

Public Input No. 16-NFPA [ Section No ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input Public Input No. 16-NFPA 211-2014 [ Section No. 2.3.1 ] 2.3.1 ASHRAE Publications. ASHRAE, Inc., 1791 Tullie Circle, NE, Atlanta, GA 30329-2305. ASHRAE Handbook: HVAC Systems and Equipment, 2008 2012.

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: Technical Committee on Residential Sprinkler

More information

Page 1 of 6 10/19/2016 9:49 AM. Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

Page 1 of 6 10/19/2016 9:49 AM. Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input Public Input No. 4-NFPA 111-2016 [ Section No. 1.1.4.1 ] 1.1.4.1 * This standard shall not cover the following: (1) Application of the SEPSS (2) Distribution wiring (3) Systems having total outputs less

More information

CHAPTER 14 REFERENCED STANDARDS TABLE 14-1 REFERENCED STANDARDS. Floor-Affixed Supports for Off-the-Floor Plumbing Fixtures for Public Use

CHAPTER 14 REFERENCED STANDARDS TABLE 14-1 REFERENCED STANDARDS. Floor-Affixed Supports for Off-the-Floor Plumbing Fixtures for Public Use CHAPTER 14 STANDARDS 1401.0 General. 1401.1 Standards. The standards listed in Table 14-1 are intended for use in the design, testing, and installation of materials, devices, appliances, and equipment