Committee on NFPA 30A

Size: px
Start display at page:

Download "Committee on NFPA 30A"

Transcription

1 Committee on M E M O R A N D U M TO: FROM: NFPA Technical Committee on Automotive and Marine Service Stations Patti Mucci, Administrative Assistant DATE: February 5, 00 SUBJECT: ROP Letter Ballot The ROP letter ballot for is attached. The ballot is for formally voting on whether or not you concur with the committee s actions on the proposals. Reasons must accompany all negative and abstention ballots. Please do not vote negatively because of editorial errors. However, please bring such errors to my attention for action. Please complete and return your ballot as soon as possible, but no later than Thursday, March 8, 00. As noted on the ballot form, please return the ballot to Patti Mucci either via to pmucci@nfpa.org or via fax to You may also mail your ballot to the attention of Patti Mucci at NFPA, Batterymarch Park, Quincy, MA 069. The return of ballots is required by the Regulations Governing Committee Projects. Attachment: Proposals

2 30A- Log #CP Review entire document to: ) Update any extracted material by preparing separate proposals to do so, and ) review and update references to other organizations documents, by preparing proposal(s) as required. To conform to the NFPA Regulations Governing Committee Projects. 30A- Log #CP8 Revise.7 to read: "Any liquid within the scope of this code and subject to the requirements of this code shall be known generally as either a flammable liquid or a combustible liquid and shall be defined and classified in accordance with this section." Delete.7. through The text of.7. through.7.3. will be relocated to Chapter 3. See Proposal 30A-9 (Log #CP9). The administration chapter of should not contain definitions.

3 30A-3 Log #CP4 Revise Section. to read: "National Fire Protection Association, Batterymarch Park, Quincy, MA NFPA 0, Standard for Portable Fire Extinguishers, edition. NFPA 3, Standard for the Installation of Sprinkler Systems, edition. NFPA 4, Standard for the Installation of Standpipe and Hose Systems, edition. NFPA 30, Flammable and Combustible Liquids Code, 008 edition. NFPA 3, Standard for the Installation of Oil-Burning Equipment, edition. NFPA 33, Standard for Spray Application Using Flammable or Combustible Materials, edition. NFPA 5, Standard for the Design and Installation of Oxygen Fuel Gas Systems for Welding, Cutting, and Allied Processes, 007 edition. NFPA 5B, Standard for Fire Prevention During Welding, Cutting, and Other Hot Work, edition. NFPA 5, Vehicular Fuel Systems Code, edition. NFPA 54, National Fuel Gas Code, edition. NFPA 55, Standard for the Storage, Use, and Handling of Compressed Gases and Cryogenic Fluids in Portable and Stationary Containers, Cylinders, and Tanks, edition. NFPA 58, Liquefied Petroleum Gas Code, edition. NFPA 70, National Electrical Code, 008 edition. NFPA 80, Standard for Fire Doors and Other Opening Protectives, edition. NFPA 8, Standard on Incinerators and Waste and Linen Handling Systems and Equipment, edition. NFPA 85, Boiler and Combustion Systems Hazards Code, edition. NFPA 86, Standard for Ovens and Furnaces, edition. NFPA 90A, Standard for the Installation of Air-Conditioning and Ventilating Systems, edition. NFPA 9, Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and Noncombustible Particulate Solids, edition. NFPA 0, Life Safety Code, edition. NFPA, Standard for Chimneys, Fireplaces, Vents, and Solid Fuel Burning Appliances, edition. NFPA 0, Standard on Types of Building Construction, edition. NFPA 53, Standard Method of Test for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source, edition. NFPA 36, Standard for the Safeguarding of Tanks and Containers for Entry, Cleaning, or Repair, edition. NFPA 385, Standard for Tank Vehicles for Flammable and Combustible Liquids, 007 edition." Update referenced NFPA publications to current and anticipated new editions. 30A-4 Log #CP5 Revise.3. to read: "American Petroleum Institute, 0 L Street, N.W., Washington, DC API 607, Fire Test for Soft-Seated Quarter-Turn Valves, 5th 4th edition, June, 005." Update referenced API publication to current edition.

4 30A-5 Log #CP6 Revise.3. to read: "ASTM International, 00 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA ASTM D 5, Standard Method of Test for Penetration of Bituminous Materials, ASTM D 33, Standard Method of Test for Vapor Pressure of Petroleum Products (Reid Method), " Update referenced ASTM publications to current editions. 30A-6 Log #7 Bob Eugene, Underwriters Laboratories Inc. Revise text to read as follows:.3.3 UL Publications. Underwriters Laboratories Inc., 333 Pfingsten Road, Northbrook, IL UL 87, Standard for Power-Operated Dispensing Devices for Petroleum Products, 00, Revised 008. UL 84, Standard for Valves for Flammable Fluids, UL 080, Standard for Fire Resistant Tanks for Flammable and Combustible Liquids, 000. UL 085, Standard for Protected Aboveground Tanks for Flammable and Combustible Liquids, 997, Revised December 999. UL 45, Standard for Below-Grade Vaults for Flammable Liquid Storage Tanks, Update referenced standards to most recent revisions. 30A-7 Log #CP Adopt the preferred definition from the NFPA Glossary of Terms as follows: 3.3. Basement. A story of a building or a structure having one-half or more of its height below ground level on any side and to which access for emergency incident mitigation purposes is unduly restricted. ( 30B, 007) This definition is the preferred definition from the NFPA Glossary of Terms. Changing the secondary definition to the preferred definition complies with the Glossary of Terms Project. Replace the current definition of "basement" in 3.3. with the following: "3.3. Basement. For the purposes of this code, a story of a building or structure having one-half or more of its height below ground level and to which access for fire-fighting purposes is restricted. [30:008]" The word "unduly" in the preferred definition is nebulous and, within the context of, the definition extracted from NFPA 30 is more accurate. The key issue relative to is safe access to and evacuation from the basement area by emergency responders during an emergency. 3

5 30A-8 Log #CP7 Add an extract identifier at the end of the definition to read: "[30, 008]" This definition is extracted from NFPA 30 and should be identified as such. 30A-9 Log #CP9 Revise to read: "3.3.9* Liquid. Any material that () has a fluidity greater than that of 300 penetration asphalt when tested in accordance with ASTM D 5, Standard Method of Test for Penetration of Bituminous Materials or () is a viscous substance for which a specific melting point cannot be determined but that is determined to be a liquid in accordance with ASTM D 4359, Standard Test for Determining Whether a Material is a Liquid or a Solid. [30, 008] * Combustible Liquid. Any liquid that has a closed-cup flash point at or above 00 F (37.8 C), as determined by the test procedures and apparatus set forth in Section of NFPA 30, Flammable and Combustible Liquids Code. Combustible liquids shall be classified in accordance with [30, 008] (No change to Annex text.) Combustible liquids shall be classified in accordance with the following: () Class II Liquid Any liquid that has a flash point at or above 00 F (37.8 C) and below 40 F (60 C) () Class III Liquid Any liquid that has a flash point at or above 40 F (60 C) (a) Class IIIA Liquid Any liquid that has a flash point at or above 40 F (60 C), but below 00 F (93 C) (b) Class IIIB Liquid Any liquid that has a flash point at or above 00 F (93 C). [30, 008] * Flammable Liquid. Any liquid that has a closed-cup flash point below 00 F (37.8 C), as determined by the test procedures and apparatus set forth in Section of NFPA 30, Flammable and Combustible Liquids Code, and a Reid vapor pressure that does not exceed an absolute pressure of 40 psi (76 kpa) at 00 F (37.8 C), as determined by ASTM D 33, Standard Method of Test for Vapor Pressure of Petroleum Products (Reid Method) [30, 008] Flammable liquids shall be classified in accordance with [30, 008] A Flammable Liquid. For the purposes of this code, a material with a Reid Vapor Pressure greater than 068 mm Hg absolute (40 psia) is considered to be a gas and is, therefore, not within the scope of. See NFPA 58, Liquefied Petroleum Gas Code. See Annex B for information about typical liquids found at motor fuel dispensing facilities Flammable liquids shall be classified in accordance with the following: () Class IA Liquid Any liquid that has a flash point below 73 F (.8 C) and a boiling point below 00 F (37.8 C) () Class IB Liquid Any liquid that has a flash point below 73 F (.8 C) and a boiling point at or above 00 F (37.8 C) (3) Class IC Liquid Any liquid that has a flash point at or above 73 F (.8 C), but below 00 F (37.8 C). [30:4.3.] F (93 C). [30, 008] Flammable Liquid Classification Flammable Liquid Class I. Any liquid that has a closed-cup flash point below 00 F (37.8 C) and a Reid vapor pressure not exceeding an absolute pressure of 40 psi (76 kpa) at 00 F (37.8 C), as determined by ASTM D 33, Standard Test Method for Vapor Pressure of Petroleum Products (Reid Method). Flammable liquids are classified according to Section.7. This amendment essentially relocates to Chapter 3 definitions that appear in Section.7 in the current edition of. Definitions belong in Chapter 3, not the administrative chapter of the code. The text has been further amended by extracting the appropriate liquid classification information from NFPA 30. 4

6 30A-0 Log #CP0 Add an extract identifier to the end of this definition to read: "[30, 008]" This definition is extracted from NFPA 30 and should be identified as such. 30A- Log #CP Delete this definition. The term "portable tank" is not used in the. 30A- Log #CP Change the following references to NFPA 30, as indicated: In 4..4, replace " " with ".3.". In 4.3., replace "Chapters through 3 and 7" with "Chapters and 3". In 4.3., replace "Chapters through 3 and 7" with "Chapters and ". In , replace "..7." with ".7. and Section.". In , replace "5.3" with "7.8.". In , replace ".3.4" with ".3.4". In , replace "4.3..." with "Section.4". In 4.3.4(), replace "[30,.0.]" with "[30, 008]". Correction of errors in referencing text from NFPA A-3 Log #CP0 Revise to read: "Tanks storing liquid motor fuels Class I and Class II liquids at an individual site shall be limited to a maximum individual capacity of 45,400 L (,000 gal) and aggregate capacity of 8,700 L (48,000 gal) unless such tanks are installed in vaults complying with 4.3.3, in which case the maximum individual capacity shall be permitted to be 57,000 L (5,000 gal). This amendment allows the use of alternative liquid fuels that are Class III liquids. 5

7 30A-4 Log #CP Revise to read: "The provisions of this subsection shall not prohibit the dispensing of liquid motor fuels Class I and Class II liquids in the open from..... " (The remainder of the paragraph is unchanged.) This amendment allows the use of alternative liquid fuels that are Class III liquids. 30A-5 Log #CP3 Revise to read: "Vaults Each vault shall be provided with an approved vapor and liquid detection system that is and equipped with on-site audible and visual warning devices with battery back-up. [30, 008:5.5.] This requirement was taken from NFPA 30, but reworded slightly. It is more appropriate to extract the text verbatim. 30A-6 Log #3 Alex Ralston, Petcon, Inc. Revise text as follows: All openings shall be located above the maximum liquid level (for horizontal tanks). Large vertical tanks located at service stations and fleet fueling sites are 0-30 ft. high. It is not practical to fill these tanks from the top or to have manways located on the roof. These large tanks are typically filled at the bottom of the tank and the manway is located near the ground for access to the floor of the tank. Also, define openings. Do you mean any fitting or are you referring to manways? This proposal is not sufficiently specific to identify which vertical tanks are to be exempted: those that are located in a diked area or those that are the secondary containment-type and are NOT situated in a diked area. Other issues include the number and types of connections and tank capacity. The submitter is encouraged to submit an appropriate comment during the public review period. 30A-7 Log #CP4 Change title of section to read: "Corrosion Protection Control". Revise the annex by adding the following sentence at the end: " Other means of internal corrosion protection include protective coatings and linings and cathodic protection." The changes proposed correlate with NFPA 30 from on which the requirement is based. 6

8 30A-8 Log #CP5 Revise to read: "5.6. Vent piping shall meet the requirements of Section , 7.8.., , and of NFPA 30, Flammable and Combustible Liquids Code. [30, 008:5.5.]" It is more appropriate to reference the entirety of Section 7.8 to ensure that none of the vent piping provisions in NFPA 30 are overlooked or ignored. 30A-9 Log #CP Add a new 6..3 to read: "6..3 Fuel-dispensing systems, including dispensers, hoses, nozzles, breakaway fittings, swivels, flexible connectors, dispenser emergency shutoff valves, vapor recovery systems and pumps that are used for alcohol blended motor fuels shall be listed or approved for the specific purpose." This language is necessary to address existing equipment being used in more than 00 existing motor fuel dispensing facilities that dispense E85 fuel (85 percent ethanol / 5 percent gasoline). This amendment also anticipates the Environmental Protection Agency decision now pending to approve the use of alcohol-blended fuels with ethanol concentrations above 0 percent but below 85 percent. 7

9 30A-0 Log #5 Eddie Phillips, Southern Regional Fire Code Development Committee Add new sections and renumber the remaining sections as follows:. Flammable and combustible liquid fuel dispensing equipment, leak detection equipment and secondary containment equipment shall be inspected as required by the AHJ to verify that it is in proper working order and is not subject to leakage or spills. A Qualified Person shall inspect the fuel-dispensing equipment that is located outside the cabinet of the dispenser unit. All the hanging hardware and the exterior of the dispenser shall be included in this route inspection to include the nozzle, hose, breakaway valve, swivel, impact protection, and required signage. The frequency of the inspection shall be determined by the AHJ and shall be documented to show needed maintenance and corrective action. All inspection reports shall be available for review by the code official upon request. (add PEI/RP Inspection Forms from appendix B- through B-3.) A Qualified Person shall inspect the fuel-dispensing equipment that is located inside the dispenser cabinet. The interior of the fuel-dispenser cabinet shall be inspected for signs of leaks, damage, corrosion, or weathering. The frequency of the inspection shall be determined by the AHJ and shall be documented to show needed maintenance and corrective action. All inspection reports shall be available for review by the AHJ upon request. (add PEI/RP Inspection Forms from appendix B-4 through B-5.) The AHJ is authorized to require damaged or unsafe dispensing equipment, leak detection, or secondary containment equipment and to be repaired or serviced in an approved manner. This includes equipment that shows signs of physical damage, internal and external corrosion, brittleness, aging, undo wear and tear, or other damage. When maintenance to dispensing devices is necessary and such maintenance is capable of causing accidental release or ignition of liquid, the following precautions shall be taken before such maintenance is begun: () Only persons knowledgeable in performing the required maintenance shall perform the work. () All electrical power to the dispensing devices, to the pump serving the dispensing devices, and to all associated control circuits shall be shut off at the main electrical disconnect panel. (3) The emergency shutoff valve at the dispenser, if installed, shall be closed. (4) All vehicular traffic and unauthorized persons shall be prevented from coming within 6 m (0 ft) of the dispensing device. This proposal provides basic provisions for the inspection, repair, and servicing of flammable and combustible liquid dispensing system equipment, which are not currently covered in. The need for these requirements has been brought to light due to concerns with potential leakage of E85 dispensing system components, and with reported leakages from other fuel containment system components. Proposed new regulations to part authorizes the fire official to require inspection of equipment on a periodic basis, and identifies that the inspection is to verify the equipment is in proper working order and isn t leaking. The frequency and nature of the inspections is up to the discretion of the fire code official. A Qualified Person shall conduct all inspections. The PEI defines who a qualified person is, but in some locations, state and local laws and rules will define who a qualified person is under the adoption regulation. This is designed to be similar to NFPA 58 for LP gas regulations. This person is someone that has been trained to identify hazardous condition and problems, but may not be trained to the level needed to conduct maintenance as required in The annex notes provide copies of the PEI checklists that can be used as a guide for local official to monitor the inspection of the equipment to a nationally recognized association. If needed the checklists can be modified to stay within the scope of and referenced standards. Additionally, this proposed regulation authorizes the fire code official to require damaged or leaking equipment to be serviced or repaired in an approved manner. Together the new proposed provisions work well with the other requirements under maintenance. In a perfect world, having a comprehensive set of requirements covering the inspection and testing of motor vehicle fuel containment and dispensing system components, similar to requirements in place for fire alarm systems, would be the best way to cover this issue. However, since these requirements are not in place, these provisions provide some 8

10 basic requirements that may eventually lead to a more complete treatment of this area. Add a new to incorporate the existing text to read as follows: "6.3.6 Inspections. Dispensing equipment shall be periodically inspected by a person who is knowledgeable in the operation of the equipment to verify that it is in proper working order and is not leaking Exterior Inspection* A visual inspection of the fuel-dispenser and its associated hanging hardware shall be conducted. Hanging hardware shall include the following dispenser components that may be present: the hose nozzle valve, hose, breakaway valve, and hose swivel. Inspections shall be conducted at least weekly and shall be documented. Documentation shall be available for review by the authority having jurisdiction upon request. A Useful forms for documentation are presented in PEI/RP500-05, Recommended Practices for Inspection and Maintenance of Motor Fuel Dispensing Equipment and are available at Internal Dispenser Cabinet Inspection*. An inspection of the fuel-dispensing equipment that is located inside the dispenser cabinet shall be conducted. The interior of the fuel-dispenser cabinet shall be inspected for signs of leaks, damage, corrosion, or weathering, with particular attention to the sump area and joints and castings of fluid handling components. The inspection shall be conducted at least monthly and shall be documented. Documentation shall be available for review by the authority having jurisdiction upon request. A See A Maintenance. When maintenance to dispensing devices is necessary and such maintenance is capable of causing accidental release or ignition of liquid, the following precautions shall be taken before such maintenance is begun: () Only persons knowledgeable in performing the required maintenance shall perform the work. () All electrical power to the dispensing devices, to the pump serving the dispensing devices, and to all associated control circuits shall be shut off at the main electrical disconnect panel. (3) The emergency shutoff valve at the dispenser, if installed, shall be closed. (4) All vehicular traffic and unauthorized persons shall be prevented from coming within 6 m (0 ft) of the dispensing device. This revised version of the submitter's proposal has been simplified and inspection intervals have been added. 30A- Log # Charles A. Sunderhaus, OPW Fueling Components Add the following paragraph: 6.6.x Aftermarket devices such as message/advertising covers shall not be added to the fuel dispensing nozzles. Problem: These large devices affect the sensitivity of the nozzle on impact with the ground. The use of these devices may cause spills and/or injuries. Fuel dispensing nozzles must be listed, part of the requirements for listing in UL84 is the impact testing where the nozzle valve must close on impact with the ground. Add a new to read: "Any modification of the dispensing nozzle shall be listed or approved by the manufacturer of the nozzle." The submitter's proposed language would prohibit any modification at all, even one that is proved to be safe and to not interfere with the proper functioning of the dispensing nozzle. The Technical Committee's version will allow such modification. 9

11 30A- Log #CP3 Revise 6.6. to read: "6.6. An automatic-closing-type hose nozzle valve, with a latch-open device and, listed in accordance with UL 84, Standard for Valves for Flammable Fluids, with or without latch-open device, shall be provided on island-type dispensing devices used to dispense Class I or Class II liquids. This modification reflects the Technical Committee's action taken on Subsection 6.6. during the prior document revision cycle; i.e., it corrects a long-standing error. 30A-3 Log #0 Charles A. Sunderhaus, OPW Fueling Components Revise text as follows: 6.6. At any installation where the normal flow of product may be stopped other than by the hose nozzle valve, the system shall include listed equipment with a feature that causes or requires the closing of the hose nozzle valve before product flow can be resumed or before the hose nozzle valve can be replaced in its normal position in the dispenser. The vast majority of the dispensers/systems are credit card readers or pay-at-the-pump features and meet this clause. The problem is that nozzles without this device are still being installed on these dispensers causing injuries and spills because the nozzles are returned to the dispenser in the open position. I propose to require one type of nozzle on all dispensers to eliminate confusion. Revise 6.6. to read: "6.6.* At any installation where an automatic closing-type dispensing nozzle is used, the nozzle valve the normal flow of product may be stopped other than by the hose nozzle valve, the system shall include listed equipment with a feature that causes or requires the closing of the hose nozzle valve before product flow can be resumed or before the hose nozzle valve can be replaced in its normal position in the dispenser. This revision to 6.6. ensures that the requirement applies to any situation where an automatic closing-type dispensing nozzle is used. 30A-4 Log #CP5 Revise to read: "6.6.4 Dispensing nozzles used at marine motor fuel dispensing facilities shall be of the listed automatic-closing-type hose nozzle valve without a latch-open device." This revised wording correlates with 6.6., as amended in Proposal 30A- (Log #CP3). 0

12 30A-5 Log #4 Jon Nisja, Northcentral Regional Fire Code Development Committee Revise text to read as follows: Fuel dispensing systems shall be provided with one or more clearly identified emergency shutoff devices or electrical disconnects. Each such disconnect shall be identified by an approved sign stating EMERGENCY PUMP SHUTOFF in in. (50 mm) red capital letters. Such devices or disconnects shall be installed in approved locations but not less than 6 m (0 ft) or more than 30 m (00 ft) from the fuel dispensing devices that they serve. Emergency shutoff devices or electrical disconnects shall disconnect power to all dispensing devices; to all remote pumps serving the dispensing devices; to all associated power, control, and signal circuits; and to all other electrical equipment in the hazardous (classified) locations surrounding the fuel dispensing devices. When more than one emergency shutoff device or electrical disconnect is provided, all devices shall be interconnected. Resetting from an emergency shutoff condition shall require manual intervention and the manner of resetting shall be approved by the authority having jurisdiction. Exception: Intrinsically safe electrical equipment need not meet this requirement. The proposed text is from.5.3. There is no specific guidance on the size of the sign. The text is consistent with current text within and provides specific requirements on the size of the letters on the sign. needed. The submitter has not presented evidence that specific guidance for the sign or its size is 30A-6 Log #6 Jon Nisja, Northcentral Regional Fire Code Development Committee Add a new 6.7. to read: Revise to read: Emergency Electrical Disconnect devices shall be located in an approved location and labeled with an approved sign stating EMERGENCY FUEL SHUTOFF. Shut-offs should be labeled as to their operation so they can be identified by attendants and/or patrons that may be required to use them. The location of these devices should be placed in a readily accessible location outside the building for use in an emergency. The location should be approved by the AHJ. approved location Section 6.7 already requires the device to be "clearly identified" and to be located in an

13 30A-7 Log #4 Jon Nisja, Northcentral Regional Fire Code Development Committee Revise text to read as follows: The occupancy classification of a motor fuel dispensing facility that is located inside a building or structure shall be a low general hazard industrial occupancy as defined in NFPA 0, Life Safety Code. NFPA 0 does not use the term low hazard industrial occupancy. Revise 7.3. to read: "7.3. Occupancy Classification. The occupancy classification of a motor fuel dispensing facility that is located inside a building or structure shall be a special purpose low hazard industrial occupancy as defined in NFPA 0, Life Safety Code." already characterizes motor fuel dispensing facilities as "special purpose industrial" occupancies, for purposes of applying the egress requirements of NFPA 0. The risk addressed by 7.3. is commensurate. 30A-8 Log #9 Jon Nisja, Northcentral Regional Fire Code Development Committee Revise text to read as follows: Fixed Fire Protection. Automatic sprinkler protection installed in accordance with the requirements of NFPA 3, Standard for the Installation of Sprinkler Systems, shall be provided in major repair garages, as herein defined, when any of the following conditions exist: () The building housing the major repair garage is two or more stories levels in height, including basements, and the aggregate area of all levels combined exceeds,000 ft any one of the floors exceeds 930 m (0,000 ft ). () The major repair garage is one story and exceeds 5 m (,000 ft ). (3) The major repair garage is servicing vehicles parked in the basement of the building. Subsection should clarify that the requirement applies to the entire building; the entire building does not have to be used as a repair garage to utilize this requirement. The current language of section would allow a large area without sprinkler protection. (Example: 3 story building, 9,000 ft per floor would not require sprinkler protection.) The submitter has provided no justification or fire incident data to support this amendment. Also, the threshold areas now in are identical to those in the model building codes. The Technical Committee notes that the submitter has submitted two different proposals on 7.4.6, each with different criteria. See Proposal 30A-9 (Log #7).

14 30A-9 Log #7 Jon Nisja, Northcentral Regional Fire Code Development Committee Revise text to read as follows: Automatic sprinkler protection installed in accordance with the requirements of NFPA 3,, shall be provided in major repair garages, as herein defined, when any of the following conditions exist: () The major repair garage is two or more stories in height, including basements, and any one of the floors exceeds 930 m (0,000 5,000 ft ). () The major repair garage is one story and exceeds 5 m (,000 5,000 ft ). (3) The major repair garage is servicing vehicles parked in the basement of the building. Repair garages typical handle, store, and use flammable and combustible liquids at or below their flashpoints. The sprinkler thresholds for requiring automatic fire sprinklers should be lowered to 5,000 square feet. This would contain fires in repair garages and permit occupants to escape from below grade pits or areas with greater safety. The submitter has provided no justification or fire incident data to support this amendment. Also, the threshold areas now in are identical to those in the model building codes. The Technical Committee notes that the submitter has submitted two different proposals on 7.4.6, each with different criteria. See Proposal 30A-8 (Log #9). 30A-30 Log #CP9 Revise to read: "Where major repairs are conducted on the fuel systems of CNG-fueled vehicles or LNG-fueled vehicles, open flame heaters or heating equipment with exposed surfaces having a temperature in excess of 399 C (750 F) shall not be permitted in areas subject to ignitible concentrations of gas. This change clarifies the intent of this requirement. The Technical Committee has determined that this proposed amendment should be directed for action to the Task Group charged with developing amendments to Chapter, as this amendment should also address gaseous and liquid hydrogen fuels. As currently proposed, it is not complete. 3

15 30A-3 Log # Thomas P. Hammerberg, Automatic Fire Alarm Association, Bruce Fraser, Shane M. Clary Revise the accepted text and add a new 7.7.3: The circuits required by 7.7. shall be required to be monitored for integrity in accordance with NFPA 7. Renumber the existing to Due to the nature of this type of system, the circuits required by need to be monitored for integrity so that if there is a fault on the circuit wiring, a trouble signal will be generated at the protected premises. Add a new to read: " The circuits of the detection system required by shall be monitored for integrity in accordance with NFPA 7." This accomplishes the submitters intent without rearranging the current text. 4

16 30A-3 Log # Thomas P. Hammerberg, Automatic Fire Alarm Association, Bruce Fraser, Shane M. Clary Revise the accepted text and add a new 7.7.4: This system shall be electrically supervised by the building's fire alarm system, where present. It shall be a supervisory signal. Renumber the existing as required. This system needs to be electrically supervised by the building's fire alarm system. The proposed text does not require that fire alarm system be installed for this purpose, but if one is present, the Gas Detection System needs to be supervised. The Gas Detection System may be in another part of the protected premises. The action taken on Proposal 30A-3 (Log #) accomplishes the intent of this proposal. 5

17 30A-33 Log #CP7 Revise Section 8.3 to read as follows: "8.3 Installation in Classified Locations Where Class I liquids are stored, handled, or dispensed, electrical wiring and electrical utilization equipment shall be designed and installed in accordance with the requirements for Class I, Division or Division classified locations, as set forth in Table 8.3. and in NFPA 70, National Electrical Code. Exception: The storage, handling, and dispensing of methyl alcohol based windshield washer fluids shall not cause an area to be designated as a hazardous (classified) location. 8.3.* Table 8.3. shall be used to delineate and classify areas for the purposes of installing electrical wiring and electrical utilization equipment where Class I liquids are stored, handled, or dispensed. (See also Figure 8.3..) A designated classified area, as specified in Table 8.3., shall not extend beyond a floor, wall, roof, or other solid partition that has no openings The area classifications given in Table 8.3. shall be based on the premise that the installation meets the applicable requirements of this code in all respects. Should this not be the case, the authority having jurisdiction shall be permitted to determine the extent of the classified area All electrical wiring and electrical utilization equipment that is integral with the dispensing hose or dispensing nozzle shall be approved for use in Class I, Division classified locations Where Class I liquids are stored, handled, or dispensed, electrical wiring and electrical utilization equipment shall be designed and installed in accordance with the requirements for Class I, Division or Division classified locations, as set forth in Table 8.3. and in NFPA 70, National Electrical Code. Exception: The storage, handling, and dispensing of methyl alcohol based windshield washer fluids shall not cause an area to be designated as a hazardous (classified) location." Rest of text remains unchanged. This revision clarifies and emphasizes that Table 8.3. applies only to Class I liquids. 6

18 30A-34 Log #3 Marshall A. Klein, Marshall A. Klein & Associates, Inc. The purpose of this Tentative Interim Amendment is two-fold: it is intended to extend the utility of Table 8.3., which specifies the extent of hazardous (classified) locations in motor fuel dispensing facilities and automotive repair garages, by incorporating the (European) Zone system of designating hazardous (classified) locations and the allowable wiring methods and electrical utilization devices that can be used in them. It is also intended that this be done in a timely fashion, so that this revised table can be proposed for incorporation, as extracted text, into the 0 edition of the (NEC). This latter will be accomplished by means of a public comment to be submitted by the Technical Committee on Automotive and Marine Service Stations to its existing proposal to the NEC. The Technical Committee on Automotive and Marine Service Stations has revised Table 8.3. by adding a new column in which the proper Zone designations are given. Since is used internationally, the Technical Committee considers it important that provide accurate and compatible information in this regard. This will assist users when specifying equipment and devices in the international market. The addition of the Zone designations to Table 8.3. has been done in a manner to correlate with Article 505 of the NEC. The Technical Committee has also taken the opportunity to reorganize and simplify the Table so that it is easier to understand and interpret. For example, the descriptions of Extent of Classified Area have been editorially revised so that they use the same grammatical terminology. The Technical Committee has added several additional footnotes to the Table to further clarify the entries in the table, their application, and their relationship to NEC Articles 5 and 54. The Technical Committee on Automotive and Marine Service Stations considers it imperative that there be no inconsistencies between Table 8.3. of and Table 54.3(B)() of the NEC. The latter is extracted from the 008 edition of. Because the NEC is in the Annual 00 revision cycle and is in the Annual 0 revision cycle, the Technical Committee must process this change as a TIA. Otherwise, the revisions to Table 8.3. cannot be incorporated into the NEC until the 04 edition of that Code. It is the opinion of the Technical Committee that this meets the criterion of 5.(b) of the. The Technical Committee also believes that this TIA meets the criterion of 5.(e) of the by recognizing the use of the Zone concept in motor fuel dispensing facilities and repair garages. The Technical Committee notes that this has already been accomplished in other related documents, such as NFPA 30,, and NFPA 33,. Revise Table 8.3. as follows: ***Insert table Here - 30A_ L3 CA Table 8.3..doc*** The revised Table 8.3. proposed by the submitter originated as a Tentative Interim 7

19 Table 8.3. Extent of Class I Hazardous (Classified) Locations Class I Location Division Zone Extent of Classified Location Dispensing Device (except Overhead Type),3 Under dispenser containment Entire space within and under dispenser pit or containment Dispenser Within 8 in. (450 mm) of dispenser enclosure or that portion of dispenser enclosure containing liquid handling components, extending horizontally in all directions and down to grade level Outdoor Up to 8 in. (450 mm) above grade level, extending 0 ft (6 m) horizontally in all directions from dispenser enclosure Indoor - with mechanical ventilation Up to 8 in. (450 mm) above floor level, extending 0 ft. (6 m) horizontally in all directions from dispenser enclosure - with gravity ventilation Up to 8 in. (450 mm) above floor level, extending 5 ft (7.5 m) horizontally in all directions from dispenser enclosure Dispensing Device Overhead Type 4 Space within dispenser enclosure and all electrical equipment integral with dispensing hose or nozzle Within 8 in. (450 mm) of dispenser enclosure, extending horizontally in all directions and down to grade level Repair Garage, Major 5 where Class I liquids or gaseous fuels are transferred or dispensed 6 (See and 8.3.5) Up to 8 in. (450 mm) above grade level, extending 0 ft (6 m) horizontally in all directions from a point vertically below edge of dispenser enclosure Entire space within any pit, belowgrade work area, or subfloor work area that is not ventilated Entire space within any pit, belowgrade work area, or subfloor work area that is provided with ventilation of at least ft 3 /min/ft (0.3 m 3 /min/m ) of floor area, with suction taken from a point within in. (300 mm) of floor level (See ) Up to 8 in. (450 mm) above floor level of the room, except as noted below, for entire floor area Up to 8 in. (450 mm) above floor level of the room where room is provided with ventilation of at least ft 3 /min/ft (0.3 m 3 /min/m ) of floor area, with suction taken from a point within in. (300 mm) of floor level Within 3 ft (0.9 m) of any fill or dispensing point, extending in all directions specific areas adjacent to classified locations Repair Garage, Minor 5 where Class I liquid or gaseous fuels are not transferred or dispensed (See and 8.3.5) Areas adjacent to classified locations where flammable vapors are not likely to be released, such as stock rooms, switchboard rooms, and other similar locations, shall not be classified where mechanically ventilated at a rate of four or more air changes per hour, or designed with positive air pressure, or where effectively cut off by walls or partitions Entire space within any pit, belowgrade work area, or subfloor work area that is not ventilated Up to 8 in. (450 mm) above floor level, extending 3 ft (0.9 m) horizontally in all directions from opening to any pit, belowgrade work area, or subfloor work area that is not ventilated Entire space within any pit, belowgrade work area, or subfloor work area that is provided with ventilation of at least ft 3 /min/ft (0.3 m 3 /min/m ) of floor area, with suction taken from a point within in. (300 mm) of floor level (See ) specific areas adjacent to classified locations Areas adjacent to classified locations where flammable vapors are not likely to be released, such as stock rooms, switchboard rooms, and other similar locations, where mechanically ventilated at a rate of four or more air changes per hour, or designed with positive air pressure, or where effectively cut off by walls or partitions 30A Table Rec from TIA 956 [SC 30A-08-](A0 ROP)

20 Table 8.3. Extent of Class I Hazardous (Classified) Locations Class I Location Division Zone Extent of Classified Location Repair Garage, Major 5 where lighter-than air gaseous fueled 7 vehicles are repaired or stored Within 8 in. (450 mm) of ceiling, except as noted below Within 8 in. (450 mm) of ceiling where ventilation of at least ft 3 /min/ft of floor area is provided and suction is taken from a point within 8 in. (450 mm) of the highest point in the ceiling specific areas adjacent to classified locations Areas adjacent to classified locations where flammable vapors are not likely to be released, such as stock rooms, switchboard rooms, and other similar locations, where mechanically ventilated at a rate of four or more air changes per hour, or designed with positive air pressure, or where effectively cut off by walls or partitions Remote Pump Outdoor Entire space within any pit or box below grade level, any part of which is within 0 ft (3 m) horizontally from any edge of pump Within 3 ft (900 mm) of any edge of pump, extending horizontally in all directions Up to 8 in. (450 mm) above grade level, extending 0 ft (3 m) horizontally in all directions from any edge of pump Indoor Entire space within any pit Within 5 ft (.5 m) of any edge of pump, extending in all directions Up to 3 ft (900 mm) above floor level, extending 5 ft (7.5) horizontally in all directions from any edge of pump Sales, Storage, Rest Rooms including structures (such as the attendant s kiosk) on or adjacent to dispensers Except as noted below Entire volume, if there is any opening to room within the extent of a Division or Zone location Tank, Aboveground Inside tank 0 Entire volume, if there is any opening to room within the extent of a Division or Zone location Entire inside volume Shell, ends, roof, dike area Entire space within dike, where dike height exceeds distance from tank shell to inside of dike wall for more than 50 percent of tank circumference Entire space within dike, where dike height does not exceed distance from tank shell to inside of dike wall for more than 50 percent of tank circumference Within 0 ft (3 m) of shell, ends, or roof of tank Vent Within 5 ft (.5 m) of open end of vent, extending in all directions Tank, Underground Inside tank 0 Between 5 ft and 0 ft (.5 m and 3 m) from open end of vent, extending in all directions Entire inside volume Fill Opening Entire space within any pit or box below grade level, any part of which is within a Division or Division classified location or within a Zone or Zone classified location Up to 8 in. (450 mm) above grade level, extending 5 ft (.5 m) horizontally in all directions from any tight-fill connection and extending 0 ft (3 m) horizontally in all directions from any loose-fill connection Vent Within 5 ft (.5 m) of open end of vent, extending in all directions Between 5 ft and 0 ft (.5 m and 3 m) from open end of vent, extending in all directions 30A Table Rec from TIA 956 [SC 30A-08-](A0 ROP)

21 Vapor Processing System Pits Table 8.3. Extent of Class I Hazardous (Classified) Locations (continued) Class I Location Division Zone Extent of Classified Location Entire space within any pit or box below grade level, any part of which: () is within a Division or Division classified location; () is within a Zone or Zone classified location; (3) houses any equipment used to transfer or process vapors Equipment in protective enclosures Entire space within enclosure Equipment not within protective enclosure Within 8 in. (450 mm) of equipment containing flammable vapors or liquid, extending horizontally in all directions and down to grade level Up to 8 in. (450 mm) above grade level within 0 ft (3 m) horizontally of the vapor processing equipment - Equipment enclosure Entire space within enclosure, if flammable vapor or liquid is present under normal operating conditions Entire space within enclosure, if flammable vapor or liquid is not present under normal operating conditions - Vacuum assist blower Within 8 in. (450 mm) of blower, extending horizontally in all directions and down to grade level Up to 8 in. (450 mm) above grade level, extending 0 ft (3 m) horizontally in all directions Vault Entire interior space, if Class I liquids are stored within For marine application, grade level means the surface of a pier, extending down to water level. Refer to Figure 8.3. for an illustration of classified areas around dispensing devices. 3 Area classification inside the dispenser enclosure is covered in UL 87, Standard for Power-Operated Dispensing Devices for Petroleum Products. 4 Ceiling-mounted hose reel. 5 The terms repair garage, major and repair garage, minor are intended to correlate with Article 5.3 of NFPA 70, National Electrical Code. For the purposes of application of this table, these terms do not include associated floor space used for offices, parking, or showrooms 6 Includes draining of Class I liquids from vehicle 7 Includes fuels such as hydrogen and natural gas, but not LPG 30A Table Rec from TIA 956 [SC 30A-08-](A0 ROP)

22 Location Dispensing Device (except Overhead Type),3 Table 8.3. Class I Locations Motor Fuel Dispensing Facilities Class I Division Zone (Group D) (Group IIA) Extent of Classified Location Under dispenser containment Entire space within and under dispenser pit or containment Dispenser Within 450 mm (8 in) of dispenser enclosure or that portion of dispenser enclosure containing liquid handling components, extending horizontally in all directions and down to grade level Outdoor Up to 450 mm (8 in) above grade level, extending 6 m (0 ft) horizontally in all directions from dispenser enclosure Indoor - with mechanical ventilation Up to 450 mm (8 in) above floor level, extending 6 m (0 ft) horizontally in all directions from dispenser enclosure - with gravity ventilation Up to 450 mm (8 in) above floor level, extending 7.5 m (5 ft) horizontally in all directions from dispenser enclosure Dispensing Device Overhead Type 4 Space within dispenser enclosure and all electrical equipment integral with dispensing hose or nozzle Within 450 mm (8 in) of dispenser enclosure, extending horizontally in all directions and down to grade level Up to 450 mm (8 in) above grade level, extending 6 m (0 ft) horizontally in all directions from a point vertically below edge of dispenser enclosure Repair Garage, Major 5 where Class I liquids or gaseous fuels are transferred Entire space within any pit, belowgrade work area, or subfloor work area that is not ventilated Log #3 Table 8.3. CA A0 ROP

23 or dispensed 6 (See 33.. and 8.3.5) specific areas adjacent to classified locations Entire space within any pit, belowgrade work area, or subfloor work area that is provided with ventilation of at least 0.3 m 3 /min/m (ft 3 /min/ft ) of floor area, with suction taken from a point within 300 mm ( in) of floor level (See ) Up to 450 mm (8 in) above floor level of the room, except as noted below, for entire floor area Up to 450 mm (8 in) above floor level of the room where room is provided with ventilation of at least 0.3 m 3 /min/m (ft 3 /min/ft ) of floor area, with suction taken from a point within 300 mm ( in) of floor level Within 0.9 m (3 ft) of any fill or dispensing point, extending in all directions Areas adjacent to classified locations where flammable vapors are not likely to be released, such as stock rooms, switchboard rooms, and other similar locations, where mechanically ventilated at a rate of four or more air changes per hour or designed with positive air pressure or where effectively cut off by walls or partitions Repair Garage, Minor 5 where Class I liquids or gaseous fuels are not transferred or dispensed 6 (See 33.. and 8.3.5) specific areas adjacent to classified locations Entire space within any pit, belowgrade work area, or subfloor work area that is not ventilated Up to 450 mm (8 in) above floor level, extending 0.9 m (3 ft) horizontally in all directions from opening to any pit, belowgrade work area, or subfloor work area that is not ventilated Entire space within any pit, belowgrade work area, or subfloor work area that is provided with ventilation of at least 0.3 m 3 /min/m (ft 3 /min/ft ) of floor area, with suction taken from a point within 300 mm ( in) of floor level (See ) Areas adjacent to classified locations where flammable vapors are not likely to be Log #3 Table 8.3. CA A0 ROP

24 released, such as stock rooms, switchboard rooms, and other similar locations, where mechanically ventilated at a rate of four or more air changes per hour or designed with positive air pressure or where effectively cut off by walls or partitions Repair Garage, Major 5 where lighter-than-air gaseous fueled 7 vehicles are repaired or stored Within 450 mm (8 in) of ceiling, except as noted below Within 450 mm (8 in) of ceiling where ventilation of at least 0.3 m 3 /min/m (ft 3 /min/ft ) of floor area, with suction taken from a point within 450 mm (8 in) of the highest point in the ceiling specific areas adjacent to classified locations Areas adjacent to classified locations where flammable vapors are not likely to be released, such as stock rooms, switchboard rooms, and other similar locations, where mechanically ventilated at a rate of four or more air changes per hour or designed with positive air pressure or where effectively cut off by walls or partitions Remote Pump Outdoor Entire space within any pit or box below grade level, any part of which is within 3 m (0 ft) horizontally from any edge of pump Within 900 mm (3 ft) of any edge of pump, extending horizontally in all directions Up to 450 m (8 in.) above grade level, extending 3 m (0 ft) horizontally in all directions from any edge of pump Indoor Entire space within any pit Within.5 m (5 ft) of any edge of pump, extending in all directions Up to 900 mm (3 ft) above floor level, extending 7.5 m (5 ft) horizontally in all directions from any edge of pump Sales, Storage, Rest Rooms Except as noted below 3 Log #3 Table 8.3. CA A0 ROP

25 including structures (such as the attendant s kiosk) on or adjacent to dispensers Entire volume, if there is any opening to room within the extent of a Division or Zone location Entire volume, if there is any opening to room within the extent of a Division or Zone location Tank, Aboveground Inside Tank 0 Entire inside volume Shell, ends, roof, dike area Entire space within dike, where dike height exceeds distance from tank shell to inside of dike wall for more than 50 percent of tank circumference Entire space within dike, where dike height does not exceed distance from tank shell to inside of dike wall for more than 50 percent of tank circumference Vent Within 3 m (0 ft) of shell, ends, or roof of tank Within.5 m (5 ft) of open end of vent, extending in all directions Between.5 m and 3 m (5 ft and 0 ft) from open end of vent, extending in all directions Tank, Underground Inside tank 0 Entire inside volume Fill Opening Entire space within any pit or box below grade level, any part of which is within a Division or Division classified location or within a Zone or Zone classified location Up to 450 mm (8 in) above grade level, extending.5 m (5 ft) horizontally in all directions from any tight-fill connection and extending 3 m (0 ft) horizontally in all directions from any loose-fill connection Vent Within.5 m (5 ft) of open end of vent, extending in all directions 4 Log #3 Table 8.3. CA A0 ROP

26 Between.5 m and 3 m (5 ft and 0 ft) from open end of vent, extending in all directions Vapor Processing System Pits Entire space within any pit or box below grade level, any part of which: () is within a Division or Division classified location; () is within a Zone or Zone classified location; (3) houses any equipment used to transfer or process vapors Equipment in protective enclosures Entire space within enclosure Equipment not within protective enclosure Within 450 mm (8 in) of equipment containing flammable vapors or liquid, extending horizontally in all directions and down to grade level Up to 450 m (8 in) above grade level within 3 m (0 ft) horizontally of the vapor processing equipment Equipment enclosure Entire space within enclosure, if flammable vapor or liquid is present under normal operating conditions Entire space within enclosure, if flammable vapor or liquid is not present under normal operating conditions Vacuum assist blower Within 450 mm (8 in) of blower, extending horizontally in all directions and down to grade level Up to 450 mm (8 in) above grade level, extending 3 m (0 ft) horizontally in all directions Vault Entire interior space, if Class I liquids are stored within For marine application, grade level means the surface of a pier, extending down to water level. Refer to Figure 54.3 for an illustration of classified location around dispensing devices. 3 Area classification inside the dispenser enclosure is covered in UL 87, Standard for Power-Operated Dispensing Devices for Petroleum Products. 4 Ceiling-mounted hose reel. 5 The terms repair garage, major and repair garage, minor are intended to correlate with Article 5 Log #3 Table 8.3. CA A0 ROP

27 5.3 of NFPA 70, National Electrical Code. For the purposes of application of this table, these terms do not include associated floor space used for offices, parking, or showrooms. 6 Includes draining of Class I liquids from vehicles. 7 Includes fuels such as hydrogen and natural gas, but not LPG. 6 Log #3 Table 8.3. CA A0 ROP

28 Amendment to the 008 edition of. This same revision was proposed to Code Making Panel 4 as an update to its extracted version of the table, Table 54.3(B)() of the National Electrical Code (NEC). In the course of CMP-4's adoption of the revisions, some minor changes were effected to meet the needs of the NEC. The version of Table 8.3. being adopted here correlates with the version that will appear as Table 54.3(B)() in the 0 edition of the NEC. 30A-35 Log #CP4 Revise Figure 8.3. by:. Eliminating the Division shading around the dispensers in the plan view.. Aligning the plan and elevation views. 3. Adding the Zone and Zone designations. 4. In the elevation view, show the Division shading as 8 in. above the island. I.e., the Division location should be 8 in. above the island, then "step down" to 8 in. above grade. ***Insert Artwork 30A Log CP4 - Figure 8.3..pdf*** These changes () eliminate erroneous Division classification around the dispenser; () add the proper Zone designations; and (3) show the proper extension of the Division (Zone) classification with respect to the height of the island and grade surface. 30A-36 Log # Donald R. Offerdahl, North Dakota State Electrical Board Revise text to read as follows: Rename figure 8.3. to 8.3.(a) and insert new figure 8.3. (b) ***Insert 30A_L_Figure8.3.(b) here*** The existing figure 8.3. does not cover all types of dispensers. Above ground tank with a dispenser is a common use in United States. There is a misinterpretation of the classified areas. This new figure will help resolve that problem. The proposed classification scheme conflicts with the criteria in Table 8.3. for aboveground tanks. A Task Group has been formed to address this issue and to propose a revised diagram and related text during the comment period. 8

29

30 30A_L_Figure8.3.(b)_R

First Revision No. 1-NFPA 30A-2015 [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

First Revision No. 1-NFPA 30A-2015 [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement of 35 1/21/2016 7:56 AM First Revision No. 1-NFPA 30A-2015 [ Section No. 1.1.3 ] 1.1.3* This code shall not apply to those motor fuel dispensing facilities where only liquefied petroleum gas (LP-Gas),

More information

Committee on NFPA 51A

Committee on NFPA 51A Committee on M E M O R A N D U M TO: FROM: NFPA Technical Committee on Industrial and Medical Gases Patti Mucci, Administrative Assistant DATE: May 6, 2010 SUBJECT: ROC Letter Ballot The ROC letter ballot

More information

Throughout standard remove references to the following and replace with the following:

Throughout standard remove references to the following and replace with the following: of 105 1/21/2016 7:49 AM Public Input No. 2-NFPA 30A-2015 [ Global Input ] Throughout standard remove references to the following and replace with the following: (1) ANSI/UL and replace with UL. (2) ANSI

More information

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot M E M O R A N D U M TO: FROM: NFPA Technical Committee on Building Service and Fire Protection Equipment Gregory Harrington, P.E., Staff Liaison DATE: October 1, 2009 SUBJECT: NFPA 5000 A2011 ROP Letter

More information

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement 1 of 7 3/4/2016 12:02 PM Second Revision No. 5-NFPA 56-2016 [ Section No. 1.1.2 ] 1.1.2 Nonapplication of Standard. This standard shall not apply to the following items: (1)* Piping systems covered by

More information

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content Based on the 2018 International Fire Code, (IFC ) The International Fire Code (IFC ), establishes minimum regulations for fire safety. This handout will identify important changes in the IFC from 2015

More information

M E M O R A N D U M. NFPA Technical Committee on Alternative Approaches to Life Safety. SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle)

M E M O R A N D U M. NFPA Technical Committee on Alternative Approaches to Life Safety. SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle) M E M O R A N D U M TO: FROM: NFPA Technical Committee on Alternative Approaches to Life Safety Linda MacKay DATE: December 28, 2010 SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle) The ROP letter

More information

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input of 280 2/6/2015 12:06 PM Public Input No. 1-NFPA 58-2013 [ Global Input ] NOTE: This public input originates from Tentative Interim Amendment 58-14-1 (TIA 1079) issued by the Standards Council on August

More information

Committee on NFPA 85

Committee on NFPA 85 Committee on NFPA 85 M E M O R A N D U M TO: FROM: NFPA Technical Committee on Single Burner Boilers Patti Mucci, Technical Assistant II DATE: August 5, 2009 SUBJECT: NFPA ROP Letter Ballot The ROP letter

More information

Above Ground Fuel Tank Requirements

Above Ground Fuel Tank Requirements FIRE DEPARTMENT in cooperation with Above Ground Fuel Tank Requirements The purpose of this document is to provide information about general Fire Code requirements for above ground storage within the unincorporated

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Merchant Vessels

More information

Public Comment No. 7-NFPA 30A-2013 [ Section No ]

Public Comment No. 7-NFPA 30A-2013 [ Section No ] Page 1 of 13 Public Comment No. 7-NFPA 30A-2013 [ Section No. 6.4.2 ] 6.4.2 Additional Proposed Changes Each pump shall have installed on the discharge side a listed leak detection device that will provide

More information

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment M E M O R A N D U M TO: FROM: NFPA Technical Committee on Building Services and Fire Protection Equipment Linda MacKay DATE: November 10, 2009 SUBJECT: NFPA 5000 A2011 ROP Letter Ballot Final Results The

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Hot Work Operations

More information

Page 1 of 19 Committee Input No. 14-NFPA 33-2013 [ Global Input ] Type your content here... Supplemental Information File Name IndoorDraftforCI.docx Description This committee input would be added to new

More information

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ] 8 of 93 11/6/2015 7:41 AM Public Input No. 52-NFPA 30-2015 [ Section No. 21.2 [Excluding any Sub-Sections] ] For the purpose of this chapter, the term in this section shall have the definitions given.

More information

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016)

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Solvent Extraction Plants

More information

Page 1 of 37 Public Input No. 1-NFPA 30A-2012 [ New Section after 1.1.2 ] 1.1.3 This code shall not apply to aircraft fuel dispensing facilities. NFPA 30A is commonly referenced, in my opinion, incorrectly,

More information

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical on Laser Fire Protection Kimberly

More information

First Revision No. 20-NFPA [ Section No ]

First Revision No. 20-NFPA [ Section No ] of 25 7/15/2015 8:30 AM First Revision No. 20-NFPA 56-2015 [ Section No. 1.1.2 ] 1.1.2 Nonapplication of Standard. This standard shall not apply to the following items: (1)* Piping systems covered by NFPA

More information

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION CHAPTER 23.45 Sections LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION 23.45.100 Local amendments to the International Fire Code, 2006 Edition... 2 23.45.102.1 Construction and design provisions...

More information

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM 1 of 11 1/18/2016 5:43 PM First Revision No. 2-NFPA 51-2015 [ Global Input ] Throughout standard remove references to the following and replace with the following: (1) CGA C-7 Guide to Precautionary Labelling

More information

CENTRAL STATE HOSPITAL PLAN SAFE USE HANDLING AND STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

CENTRAL STATE HOSPITAL PLAN SAFE USE HANDLING AND STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS Page 1 of 6 CENTRAL STATE HOSPITAL PLAN SUBJECT: SAFE USE HANDLING AND STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS ANNUAL REVIEW MONTH: RESPONSIBLE FOR REVIEW: APRIL CSH SAFETY DIRECTOR LAST REVISION

More information

The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101):

The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101): The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101): 1.1.1 Title. NFPA 101, Life Safety Code, shall be known as the Life Safety Code, is cited as such, and shall

More information

Committee Input No. 60-NFPA [ Sections , ]

Committee Input No. 60-NFPA [ Sections , ] Page 1 of 15 Committee Input No. 60-NFPA 34-2013 [ Sections 3.3.7.1, 3.3.7.2 ] Sections 3.3.7.1, 3.3.7.2 3.3.7.1 Combustible Liquid. A Any liquid that has a closed-cup flash point at or above 100 F (37.8

More information

BUILDING/FIRE CODE REFERENCES 2006 EDITION

BUILDING/FIRE CODE REFERENCES 2006 EDITION BUILDING/FIRE CODE REFERENCES 2006 EDITION This document provides a cross reference with the International Building Code and NFPA 1/Uniform Fire The IBC references the IFC in 97 Code sections. This document

More information

Changes for the New Edition. Senior Engineer, NFPA NFPA

Changes for the New Edition. Senior Engineer, NFPA NFPA Changes for the New Edition Denise Beach Senior Engineer, NFPA NFPA Overview NFPA 58-2014 Substantive Changes TIAs 2017 Edition NFPA 58-2014 Substantive Changes Bulk and Industrial Plants 3.3.10 Bulk Plant.

More information

ERRATA TO THE 2000 INTERNATIONAL FIRE CODE. Fourth Printing, January 2002 Updated March 29, 2002

ERRATA TO THE 2000 INTERNATIONAL FIRE CODE. Fourth Printing, January 2002 Updated March 29, 2002 ERRATA TO THE 2000 INTERNATIONAL FIRE CODE Fourth Printing, January 2002 Updated March 29, 2002 Table 2306.2 General Fire Protection and Life Safety Requirements In column 2 (Size of High Piled Storage

More information

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951) Riverside County Fire Department Office of the Fire Marshal 2300 Market St., Ste. 150, Riverside, CA 92501 Ph. (951) 955-4777 Fax (951) 955-4886 Technical Policy Title: Plant Processing and Extraction

More information

Page 1 of 15 Second Revision No. 8-NFPA 82-2013 [ Section No. 2.2 ] 2.2 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471. NFPA 13, Standard for the Installation

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Mercantile and

More information

Laboratories and Hazardous Materials. Company Overview

Laboratories and Hazardous Materials. Company Overview Laboratories and Hazardous Materials Don E. Contois, P.E. Sam Sinapi Company Overview R.W. Sullivan Engineering (RWS) was established in 1945 and currently has 95 employees. RWS is a full service engineering

More information

Second Revision No. 3-NFPA [ Section No. 2.3 ]

Second Revision No. 3-NFPA [ Section No. 2.3 ] Second Revision No. 3-NFPA 804-2014 [ Section No. 2.3 ] 2.3 Other Publications. 2.3.1 ASME Publications. American Society of Mechanical Engineers, Three Park Avenue, New York, NY 10016-5990. ASME Boiler

More information

TRI-LAKES MONUMENT FIRE PROTECTION DISTRICT

TRI-LAKES MONUMENT FIRE PROTECTION DISTRICT TRI-LAKES MONUMENT FIRE PROTECTION DISTRICT LOCAL AMENDMENTS INTERNATIONAL FIRE CODE 2009 December 5, 2012 1 Chapter 1 Administration Chapter 5 Fire Service Features Chapter 9 Fire Protection Systems Chapter

More information

Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ]

Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ] Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard and shall be considered

More information

National Fire Protection Association M E M O R A N D U M. NFPA Technical Committee on Construction and Demolition

National Fire Protection Association M E M O R A N D U M. NFPA Technical Committee on Construction and Demolition National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Construction

More information

Page 1 of 13 Second Revision No. 1-NFPA 326-2014 [ Section No. 2.3.1 ] 2.3.1 ACGIH Publications. American Conference of Governmental Industrial Hygienists, 1330 Kemper Meadow Drive, Cincinnati, OH 45240-1634.

More information

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] 1.3 Application. 1.3.1 This standard shall apply to all systems for the movement of environmental air in structures that serve the following, except

More information

Report on First Revisions with Statement June 2014 NFPA 101

Report on First Revisions with Statement June 2014 NFPA 101 101 FR6005 SAF-BCF (32.2.1.1.2) Recommendation: 32.2.1.1.2 Where there are sleeping accommodations for more than 16 residents are provided, the occupancy shall be classified as a large facility in accordance

More information

Adobe Connect - Invitation to NFPA 385 Second Draft Web Conference

Adobe Connect - Invitation to NFPA 385 Second Draft Web Conference Matthews, Diane Subject: Location: Start: End: Show Time As: Recurrence: Meeting Status: Organizer: Required Attendees: Adobe Connect - Invitation to NFPA 385 Second Draft Web Conference http://nfpa.adobeconnect.com/rpbmeet/

More information

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region The following sections, paragraphs, and sentences of the 2015 International Existing

More information

Plant Processing and Extraction Facilities

Plant Processing and Extraction Facilities Orange County Fire Authority Community Risk Reduction 1 Fire Authority Road, Building A, Irvine, CA. 92602 www.ocfa.org 714-573-6180 Plant Processing and Extraction Facilities Guideline G-16 Serving the

More information

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES CHAPTER 18 SECTION 1801 GENERAL 1801.1 Scope. Semiconductor fabrication facilities and comparable research and development areas classified as Group H-5 shall comply with this chapter and the International

More information

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010) CHAPTER 1 SCOPE AND ADMINISTRATION 102.7 Referenced codes and standards. The codes and standards referenced in this code shall be those that are listed in Chapter 45 47 and such codes and standards shall

More information

GASEOUS HYDROGEN SYSTEMS

GASEOUS HYDROGEN SYSTEMS CHAPTER 7 GASEOUS HYDROGEN SYSTEMS SECTION 701 GENERAL 701.1 Scope. The installation of gaseous hydrogen systems shall comply with this chapter and Chapters 30 and 35 of the Fire Compressed gases shall

More information

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION CHAPTER 14 FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION SECTION FC 1401 GENERAL 1401.1 Scope. This chapter shall govern fire safety measures during the construction, alteration, or demolition

More information

2012 International Fire Code Significant Changes. IFC Background. Purpose IBC and 2012 NFPA 101 Significant Means of Egress Changes

2012 International Fire Code Significant Changes. IFC Background. Purpose IBC and 2012 NFPA 101 Significant Means of Egress Changes 2012 International Fire Code Significant Changes Andrew M. Schneider, P.E. Senior Fire Protection Engineer aschneider@koffel.com Koffel Associates, Inc. www.koffel.com Expertly Engineering Safety From

More information

ARTICLE 25. FUEL GAS CODE

ARTICLE 25. FUEL GAS CODE ARTICLE 25. Rule 1. Indiana Fuel Gas Code, 2003 Edition (Repealed) (Repealed by Fire Prevention and Building Safety Commission; filed Mar 18, 2008, 2:32 p.m.: 20080423-IR-675070479FRA, eff 90 days after

More information

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item Public Comment No. 23-NFPA 96-2015 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM E84, Standard Test Method

More information

Second Revision No. 36-NFPA [ Detail ] Submitter Information Verification. Committee Statement 5/18/2015 1:01 PM

Second Revision No. 36-NFPA [ Detail ] Submitter Information Verification. Committee Statement 5/18/2015 1:01 PM of 66 5/18/2015 1:01 PM Second Revision No. 36-NFPA 32-2015 [ Detail ] 6.5 Solvents (See Annex C for additional information on solvents) Submittal Date: Tue Mar 17 17:20:03 EDT 2015 Committee Statement:

More information

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES CHAPTER 18 SEMICONDUCTOR FABRICATION FACILITIES SECTION 1801 GENERAL 1801.1 Scope. Semiconductor fabrication facilities and comparable research and development areas classified as Group H-5 shall comply

More information

1 Batterymarch Park, Quincy, MA Phone: Fax: M E M O R A N D U M

1 Batterymarch Park, Quincy, MA Phone: Fax: M E M O R A N D U M National Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: Technical Committee on Industrial and Medical Gases Joanne

More information

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement Second Revision No. 1-NFPA 90A-2016 [ Section No. 2.3.2 ] 2.3.2 ASTM International Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM C411, Standard

More information

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures Please note this is not an all-inclusive list. The type and complexity of your project

More information

Temporary LPG Heat for Construction Sites Information Packet

Temporary LPG Heat for Construction Sites Information Packet Temporary LPG Heat for Construction Sites Information Packet Colorado Springs Fire Department Division of the Fire Marshal February 2014 W:\Packets\Haz Mat\IFC2009_Temp_LPG_Heat_For_Construction.doc TEMPORARY

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 21 ST - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Statute or Rule Type Memo Tag These guidelines are meant solely to provide guidance to surveyors in the survey process. ST - K0300 - Other

More information

New Facilities. Minimum Requirements

New Facilities. Minimum Requirements 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Item Reference Violation General Requirements NFPA 1124-7.1.1 Retail sales of consumer fireworks in both new and existing buildings, structures, and

More information

Amendment A International Fire Code

Amendment A International Fire Code Amendment A-3 2015 International Fire Code Part 5 BUILDING REGULATIONS AND CODES International Fire Code, 2015 Edition (IFC, 2015) Part 5, Chapter 3 International Fire Code The following sections, paragraphs,

More information

Analysis of Changes for the 5 th Edition (2014) of the Florida Codes

Analysis of Changes for the 5 th Edition (2014) of the Florida Codes Analysis of Changes for the 5 th Edition (2014) of the Florida Codes Changes to the Florida Building Code, Fuel-Gas This Analysis of Changes for the 5 th Edition (2014) of the Florida Codes is intended

More information

Remove the "Exception" text to be consistent with direction provided in the MOS.

Remove the Exception text to be consistent with direction provided in the MOS. of 37 1/11/2017 7:38 AM Public Input No. 9-NFPA 88A-2015 [ Global Input ] Remove the "Exception" text to be consistent with direction provided in the MOS. The current language in 88A has numerous section

More information

OUTLINE FOR FIRE PREVENTION ACTIVITY

OUTLINE FOR FIRE PREVENTION ACTIVITY OUTLINE FOR FIRE PREVENTION ACTIVITY Background Buildings under construction present unique fire exposures that require special attention. Fires can result in major losses and long delays in the completion

More information

Page 1 of 190 Public Input No. 22-NFPA 55-2013 [ Global Input ] Throughout the document, delete ANSI from ANSI/ASME B31.3. Current Text: (multiple locations) ANSI/ASME B31.3 (found in Subsections: 2.3.2

More information

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE, 2000 EDITION SECTIONS

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE, 2000 EDITION SECTIONS CHAPTER 23.45 LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE, 2000 EDITION SECTIONS 23.45.100 Local Amendments To The International Fire Code, 2000 Edition 23.45.102.1 Construction and Design Provisions

More information

Report on First Revision June 2014 NFPA 5000

Report on First Revision June 2014 NFPA 5000 5000- Log #12 BLD-BSF Final Action: (55.2 (New) ) NOTE: This proposal appeared as Comment 5000-168 (Log #86) which was held from the A11 ROC on Proposal 5000-239. Submitter: Technical Correlating Committee

More information

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES CHAPTER 18 SEMICONDUCTOR FABRICATION FACILITIES SECTION 1801 GENERAL 1801.1 Scope. Semiconductor fabrication facilities and comparable research and development areas classified as Group H-5 shall comply

More information

2.07 Permit Application Checklist for Diesel Generators, Diesel Fire Pumps, and Fuel Tanks Serving Generators and Fire Pumps (2016)

2.07 Permit Application Checklist for Diesel Generators, Diesel Fire Pumps, and Fuel Tanks Serving Generators and Fire Pumps (2016) 2.07 Permit Application Checklist for Diesel Generators, Diesel Fire Pumps, and Fuel Tanks Serving Generators and Fire Pumps (2016) Reference: Documents referenced for this bulletin are as follows: San

More information

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements Module 3 Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements 1 WATER-BASED SUPPRESSION SYSTEMS-PART TWO This module covers: 1. Ohio Building Code requirements and when and why

More information

NFPA 45 NFPA 211 NFPA 1600

NFPA 45 NFPA 211 NFPA 1600 NFPA 45 NFPA 211 NFPA 1600 Prepared by: William E. Koffel, P.E., FSFPE Expertly Engineering Safety From Fire 1 Objectives Overview of the NFPA process Understand the scope and application of NFPA 45, NFPA

More information

M E M O R A N D U M. Please do not vote negatively because of editorial errors. However, please bring such errors to my attention for action.

M E M O R A N D U M. Please do not vote negatively because of editorial errors. However, please bring such errors to my attention for action. M E M O R A N D U M TO: FROM: NFPA Technical Committee on Fire Marshal Professional Qualifications Stacey Van Zandt DATE: July 13, 2010 SUBJECT: NFPA 1037 ROP TC Letter Ballot (F2011) The ROP letter ballot

More information

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification Public Input No. 1-NFPA 36-2013 [ Global Input ] Revise the document to eliminate the use of "Exception" text. The use of "Exception" text is inconsistent with the Manual of Style. Exception text should

More information

NFPA 37 Public Comment Responses Page 1 of 32

NFPA 37 Public Comment Responses Page 1 of 32 of 30 11/4/2016 3:05 PM Public Comment No. 6-NFPA 37-2016 [ New Section after 1.6 ] TITLE OF NEW CONTENT Type your content here... 1.7 Pressure Measurement. All pressures expressed in this document are

More information

Standard Compared 2012 Changes of the International Building Code and National Fire Protection Association- 101

Standard Compared 2012 Changes of the International Building Code and National Fire Protection Association- 101 Standard Compared 2012 Changes of the International Building Code and National Fire Protection Association- 101 For the Florida Building Commission And the Fire Code Advisory Council Introduction The scope

More information

REPORT OF THE NFPA MOTIONS COMMITTEE* ON FALL 2013 REVISION CYCLE STANDARDS

REPORT OF THE NFPA MOTIONS COMMITTEE* ON FALL 2013 REVISION CYCLE STANDARDS REPORT OF THE NFPA MOTIONS COMMITTEE* ON FALL 2013 REVISION CYCLE STANDARDS I. Introduction. This is the Motions Committee Report on Standards in the Fall 2013 Revision Cycle. The report identifies Certified

More information

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M To: From: NFPA Technical Committee on Helicopter Facilities

More information

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement of 43 10/20/2015 4:02 PM First Revision No. 2035-NFPA 101-2015 [ Global Input ] To 14.3.4.4.1, add an item (4) to read: (4) Carbon monoxide detectors shall be installed centrally located within occupiable

More information

GUIDELINES FOR EMERGENCY PLANNING AND PREPAREDNESS. High-Hazard

GUIDELINES FOR EMERGENCY PLANNING AND PREPAREDNESS. High-Hazard GUIDELINES FOR EMERGENCY PLANNING AND PREPAREDNESS High-Hazard This document shall apply to all Group H, High-Hazard occupancies. GENERAL Scope Reporting of emergencies, coordination with emergency response

More information

MEMORANDUM. NFPA Technical Committee on Fire Code (FCC-AAA) Subject: NFPA 1 Proposed Tentative Interim Amendment (TIA) No.1045

MEMORANDUM. NFPA Technical Committee on Fire Code (FCC-AAA) Subject: NFPA 1 Proposed Tentative Interim Amendment (TIA) No.1045 National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Fire Code (FCC-AAA) Gregory

More information

CUMULATIVE ANALYSIS OF UNIFORM MECHANICAL CODE CHANGES to 2003

CUMULATIVE ANALYSIS OF UNIFORM MECHANICAL CODE CHANGES to 2003 CUMULATIVE ANALYSIS OF UNIFORM MECHANICAL CODE CHANGES 2000 to 2003 The following pages contain comments regarding the changes to the 2000 edition of the UNIFORM MECHANICAL CODE (UMC ) that were made to

More information

FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE COMMITTEE

FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE COMMITTEE FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE COMMITTEE MEMORANDUM TO: FROM: NFPA 30 Technical Committee on Tank Storage and Piping Systems R. P. Benedetti DATE: November 23, 2009 SUBJECT: Agenda for December

More information

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved. Public Input No. 1-NFPA 557-2012 [ New Section after 1.5.3 ] 1.6 Approved Qualifications The design shall be prepared by a person with qualifications acceptable to the AHJ. The term designer is used in

More information

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES CHAPTER 18 SEMICONDUCTOR FABRICATION FACILITIES SECTION FC 1801 GENERAL 1801.1 Scope. This chapter shall govern the design, installation, operation and maintenance of semiconductor fabrication facilities

More information

Department of Public Safety

Department of Public Safety Terry E. Branstad Governor Kim Reynolds Lt. Governor Department of Public Safety Roxann M. Ryan Commissioner Liquid Propane Informational guide to submitting plans Plans are to be submitted to: State Fire

More information

PROPOSED CHANGE TO THE 2007 FIRE CODE (OFC)

PROPOSED CHANGE TO THE 2007 FIRE CODE (OFC) TO THE 2007 FIRE CODE (OFC) OFC Record Division: A Reference Number: 1.4.1.2. (dwelling unit) Corresponding NFC Change Division: A Reference Number: 1.4.1.2.(1) OFC Revise definition for Dwelling unit

More information

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER The 2016 Denver Building and Fire Code includes the following codes except as amendment herein. 2015 IBC (Building) 2015 IFC (Fire)

More information

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document of 79 1/27/2016 2:09 PM Public Input No. 1-NFPA 59-2015 [ Global Input ] Throughout standard remove references to the following and replace with the following: (1) ANSI/API and replace with API. (2) ANSI/UL

More information

Part I Extraction Process Equipment

Part I Extraction Process Equipment 745 West Colfax Avenue Denver, CO 80204 p: 720.913.3474 f: 720.913.3596 www.denvergov.org/fire MARIJUANA EXTRACTION GUIDELINE FOR COMMERCIAL / LICENSED FACILITIES The information contained within this

More information

SAF-BCF SECOND REVISIONS WITH STATEMENTS

SAF-BCF SECOND REVISIONS WITH STATEMENTS Page 196 of 331 32.2.1.3 ] Second Revision No. 153-NFPA 101-2013 [ New Section after 32.2.1.4 Multiple-Level Buildings. For purposes of applying requirements of this chapter that utilize the term level

More information

(h) Pesticide Application.

(h) Pesticide Application. Fire Code Cannabis Amendment Section 13.20.066 is added to the Marysville Municipal Code to read in its entirety as follows: 13.20.066 Cannabis Growing, Processing, or Extraction Facilities (a) Application.

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Mercantile and

More information

Preliminary Agenda Technical Committee on Liquefied Petroleum Gas

Preliminary Agenda Technical Committee on Liquefied Petroleum Gas Preliminary Agenda Technical Committee on Liquefied Petroleum Gas Tuesday, March 10; All Day Wednesday, March 11; All Day DRURY PLAZA HOTEL San Antonio Riverwalk 0. Administrative. A. Meeting Schedule.

More information

Pismo Beach, CA Municipal Code. Chapter 8.08 FIRE PREVENTION REGULATIONS

Pismo Beach, CA Municipal Code. Chapter 8.08 FIRE PREVENTION REGULATIONS Pismo Beach, CA Municipal Code 8.08.010 Amendments; California Fire Code. Chapter 8.08 FIRE PREVENTION REGULATIONS The California Fire Code adopted in Section 8.04.010 is modified, amended and/or supplemented

More information

Mobile Food Units. A definition of mobile food unit added in OFC Rule 2 is as follows:

Mobile Food Units. A definition of mobile food unit added in OFC Rule 2 is as follows: Technical Bulletin #18-002 February 2018 / 2017 OFC Mobile Food Units Referenced Codes and Standards: OAC 1301:7-7-3(T); OFC 320 OAC 1301:7-7-2(B); OFC 202 OAC 1301:7-7-9(F); OFC 906 NFPA 58 (2014) NFPA

More information

ICC Update - Laboratory Issues Code Changes / Proposals / Trends of Interest 10/2005

ICC Update - Laboratory Issues Code Changes / Proposals / Trends of Interest 10/2005 ICC Update - Laboratory Issues Code Changes / Proposals / Trends of Interest 10/2005 Kenneth Kretchman, CIH, CSP Mgr, Industrial Hygiene NC State University Ken_Kretchman@ncsu.edu International Building

More information

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169 7471 Phone: 617 770 3000 Fax: 617 770 0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Furnishings

More information

Report on First Revisions with Statement June 2014 NFPA 101

Report on First Revisions with Statement June 2014 NFPA 101 101 FR3002 SAF-HEA (18.1.3.2) Recommendation: 18.1.3.2 Atrium walls in accordance with 6.1.14.4.6 shall be permitted to serve as part of the separation required by 6.1.14.4.1 for creating separated occupancies

More information

FACT SHEET 2018 National Fuel Gas Code Summary List of Revisions rev

FACT SHEET 2018 National Fuel Gas Code Summary List of Revisions rev This fact sheet provides an overview of the significant revisions in the 2015 National Fuel Gas Code approved by the National Fuel Gas Code Committee, ANSI ASC Z223 and NFPA 54. These revisions are published

More information

First Revision No. 1-NFPA [ Chapter 2 ]

First Revision No. 1-NFPA [ Chapter 2 ] First Revision No. 1-NFPA 499-2014 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this recommended practice

More information

IFC Significant Changes from the 2009 to the 2015 Edition Tier 1

IFC Significant Changes from the 2009 to the 2015 Edition Tier 1 IFC Significant Changes from the 2009 to the 2015 Edition Tier 1 Several medical care definitions were created and revised in Chapter 2 of the 2012 IBC, as well as through the occupancy descriptions, and

More information

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Rancho Cucamonga Fire Protection District Prevention Bureau Standard Rancho Cucamonga Fire Protection District Prevention Bureau Standard Title: Fire Alarm and Monitoring Systems Standard # 9-3 Effective: May 2002 Number of Pages: 7 Updated: December 2016 for consistency

More information

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment February 2017 Alberta Fire Code safety equipment maintenance requirements: The Black Diamond Fire Department has

More information