3kW 6kW, QUBE Fiber Lasers
|
|
- Sharyl Carter
- 5 years ago
- Views:
Transcription
1 3kW 6kW, QUBE Fiber Lasers CONTENTS 1.1 SCOPE OPTICAL SPECIFICATION BEAM DELIVERY FIBER SPECIFICATION SHARE UNITS ALIGNMENT LASER POWER DISTRIBUTION WATER COOLING REQUIREMENTS CONTROL SAFETY FUNCTIONS PHYSICAL ENVIRONMENT COMPLIANCE DIMENSION DRAWING 8 Page 1 of 8
2 1.1 Scope High Power Fiber Lasers mounted in a floor standing cabinet, containing one or more 1.5kW OEM modules with a High Power Combiner (HPC) unit, comprehensive FiberView Control Unit and mains AC-DC power supplies Applicable Product Code Families SP-3000-F-W-xxx, SP-4500-F-W-xxx, SP-6000-F-W-xxx 1.2 Optical Specification Laser Powers 3000W, 4500W, 6000W At the Output Connector. Efficiency 28% Typical SOL, AC to optical Wavelength 1080nm ±2nm Polarisation Laser Bandwidth Random <10 nm Thermal Focus Shift 0.5 Z R / kw (Rayleigh length per kw) At the output connector Pulse Duration 10µs - CW Rise Time <5µs 10% to 90% Fall Time <6µs 90% to 10% Pulse Frequency 50kHz Maximum frequency for zero interpulse power Output Power Range 10%-105% Normal operation. Relative to specified output power Low Power Mode 30W 300W Needs separate control mode activated Warm Up Time <10mins To reach specified power stability from cold Short Term Power Stability (1Hz 1MHz) Long Term Power Stability (1 Sec 10 Hours) Fiber Laser Design Lifetime Laser Life Expectancy <2.0% RMS ±2.0% peak >40,000hrs After warm up time, under constant coolant conditions. At specified output power After warm up time, under constant coolant conditions. At specified output power MTBF, Mean Time Between Failures. Assuming 25 C coolant temp SPI s fiber lasers are designed using active and passive components including active and passive fibers. The optical characteristics of the passive components do not age appreciably over time or with use, nor do the characteristics of the active fibers. The life expectancy of the fiber laser is therefore set by its other active components, and primarily by the pump diodes. The design lifetime for the pump diodes (an ensemble of fiber coupled laser diodes) is typically 100,000 hours MTBF. This MTBF is not until catastrophic failure, but to the time at which the current required to maintain output power exceeds a design limit. The quoted MTBF is for the ensemble of all individual laser diodes. For individual laser diodes, the MTBF is considerably longer, of the order of 1,000,000 hours, but it is the ensemble MTBF that is important when considering the product lifetime. Other active components within the QUBE fiber laser have shorter predicted MTBF s but these items are considered replaceable service items. Page 2 of 8
3 1.3 Beam Delivery Fiber Specification Output Fiber Beam Quality, BPP, (mm.mrad) Beam Divergence 86% power enclosed Beam Divergence % power enclosed Output Fiber Length Options 50µm (3kW Only) 100µm enhanced 100µm PIPA-Q Output Connector As defined ISO mrad 130mrad 180mrad <280mrad <240mrad <280mrad 5m, 10m, 15m & 20m Full angle at specified power Full angle at specified power Conduit may have occasional blemishes of purely cosmetic nature. 1.4 Share Units Time Share and Energy Share Units available as Option which will be fitted into additional case fixed to top of the laser cabinet. Input Fiber Type PIPA-Q Output Fiber Type PIPA-Q LLK-D as Option Max number of output ways on integral share unit Extra Cabinet Height Time Share switching time 4 225mm 50ms 1.5 Alignment Laser Power 1mW (max) Class 2 Fitted as standard Wavelength Red ( nm) Supply Voltage 24V +/-10% Page 3 of 8
4 1.6 Power Distribution Parameter Value Output Power 3000W 4500W 6000W Frequency Voltage Range (V AC) 47-63Hz Option 1: ±10%, 3 Phase + Neutral. Option 2: V, 3 Phase + Neutral. Option 3: V, 3 Phase only Current Range (A) Water Cooling Requirements Output Power 3000W 4500W 6000W Cooling Capacity (W) (Heat Load to be removed) At EOL for specified output Coolant Temperature C. Non condensing Coolant Max Pressure Coolant Min Differential Pressure Coolant Connection Diameter TBC TBC 40mm Coolant Flow Rate (l/min) Coolant Materials Compatibility External Water Specification Appearance Minimum Clear & without sediment Copper & Plastic Maximum Particle size μm Hardness (mg CaCO 3 per litre) Electrical conductivity at 25 C mg/l 22 μscm μscm -1 DI Water NOT to be used Drinkable tap water is likely to meet these requirements, and water meeting the requirements of VDI3803. additives for prevention of corrosion, scaling and microbial growth are available commercially, for example from NALCO and Optishield, and may be used if the manufacturer s instructions are followed ph Page 4 of 8
5 1.8 Control Customer interface GUI Serial RS-232, Ethernet, CAN bus Parallel Digital (24V nominal) Analogue (0-10V) signals FiberView CAN bus uses proprietary protocol 1.9 Safety Functions Prevention of unauthorised use PLc Keyswitch Prevention of unexpected start-up PLd Reset Button Emergency stop Work enclosure interlock Fiber continuity monitoring PLe PLd PLc 1.10 Physical Please see Dimension Drawings in Section 1.13 Parameter Value Power 3000W 4500W 6000W Width Depth 793mm 945mm Height 875mm 1235mm Weight (kg) <250kg <300kg 1.11 Environment Parameter Value IP Rating Range of ambient Humidity Max Operating Altitude Storage IP52 (excluding Power Input / Control Interface which is IP50) 5-45 C 5-85% RH 35 C Max Dew Point 2000m 0 70 C 0-95% RH Storage Drain coolant below 2 C Page 5 of 8
6 1.12 Compliance Legal For legal compliance the cased laser component shall comply with the following European Union (EU) directives: EU Directive Harmonised Standard Notes 2011/65/EU 2014/35/EU 2012/19/EU EN 50581:2012 EN :2006+A1:2009 EN 60529:1989 EN :2007 EN 61140:2002/A1:2006 EN 61293:1995 None RoHS Directive Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances Low Voltage Directive Safety of machinery Electrical equipment of machines Part 1: General Degrees of protection provided by enclosures (IP code) Insulation coordination for equipment within low-voltage systems Part 1: Principles, requirements and tests (sections as required by EN60204 above) Protection against electric shock Common aspects for installation and equipment (sections as required by EN60204 above) Marking of electrical equipment with ratings related to electrical supply WEEE Directive No Harmonised Standards apply For legal compliance cased laser component shall comply with the following United States (US) Regulations: US Regulation Title 21, Chapter I, Subchapter J, Rule (a)(3) Title 47, Chapter 1, Subchapter A, Title 47, Chapter 1, Subchapter A, Note FDA - Product listing regulation FCC EMC Conducted Emissions, Class A, digital device, limits, verification only. FCC EMC Radiated Emissions, Class A, digital device, limits, verification only. Page 6 of 8
7 Marketing For Marketing proposes the relevant sections of the following Harmonised Standards shall be applied to the QUBE Fiber Laser Harmonised Standard EN :2008 EN :2013 EN :2015 EN :2012 EN11554:2008 EN 12100:2010 EN :2000+A1:2008 EN :2002+A1:2008 EN :2002+A1:2008 EN :2014 EN :2006+A2:2011 EN :2005 EN 55011:2009+A1:2010 EN :2014 Title Safety of machinery - Laser processing machines - Part 1: General safety requirements Safety of machinery - Laser processing machines - Part 3: Noise reduction and noise measurement methods for laser processing machines and hand-held processing devices and associated auxiliary equipment Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design Safety of machinery - Safety-related parts of control systems - Part 2: Validation Optics and photonics - Lasers and laser-related equipment - Test methods for laser beam power, energy and temporal characteristics Safety of machinery - General principles for design - Risk assessment and risk reduction Safety of machinery Assessment and reduction of risks arising from radiation emitted by machinery Part 1: General principles. Safety of machinery Assessment and reduction of risks arising from radiation emitted by machinery Part 2: Radiation emission measurement Procedure Safety of machinery Assessment and reduction of risks arising from radiation emitted by machinery Part 3: Reduction of radiation by attenuation or screening Safety of laser products Part 1: Equipment classification and requirements Safety of laser products Part 4: Laser guards Electromagnetic compatibility (EMC) Product family standard for machine tools Part 1: Emission Industrial, scientific and medical equipment Radio-frequency disturbance characteristics Limits and methods of measurement Electromagnetic compatibility (EMC) - Part 3-2: Limits Limits for harmonic current emissions (equipment input current 16 A per phase) Page 7 of 8
8 1.13 Dimension Drawing kW Dimension Drawing kW & 6kW Dimension Drawing Page 8 of 8
Important Safety Notice
Date: 27 th April 2015 Page 1 of 12 SPI Lasers UK Limited Safety Information High Power OEM Fibre Lasers Important Safety Notice This notice outlines important safety related information and must be read
More information9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series
COMMERCIAL LASERS 9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series Key Features Diffraction-limited light delivered through fiber termination module Single transverse mode, collimated beam
More informationG4 Pulsed Fiber Laser
G4 Pulsed Fiber Laser OEM Safety and System Integration Manual Module types C1 and C2 Module type C1 - fitted with IBeam1 delivery optic Module type C2 - fitted with IBeam2 delivery optic 1 1 Preface Definition
More informationHigh-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305
High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305 The new high-power Q305 laser is an expansion of the existing Q-Series that provides a solution for demanding applications requiring faster throughput.
More informationEnhancing Cutting Productivity by utilising Pierce Detection capability
Enhancing Cutting Productivity by utilising Pierce Detection capability March 2018 Marking Cutting Welding Micro Machining Additive Manufacturing Slide: 1 02/10/2017 CM-F00003 Rev 6 What is Piercing? Pierce
More informationG4 Pulsed Fiber Laser
G4 Pulsed Fiber Laser OEM Safety and System Integration Manual Module types B1 and B4 Module type B1 - fitted with ILLK beam delivery optic Module type B4 - fitted with ILOC beam delivery optic 1 1 Preface
More informationSPECIFICATIONS PARTICLE SENSOR KS-41B Higashimotomachi, Kokubunji, Tokyo , Japan
SPECIFICATIONS PARTICLE SENSOR KS-41B 3-20-41 Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan No. 11025-4E 18-01 Printed in Japan Outline The KS-41B is a sensor which uses the light scattering method
More informationSetting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES
L i t r o n T o t a l L a s e r C a p a b i l i t y Setting the New Standard in Chiller Technology ±0. C ZEROPOINT CHILLER SERIES Litron s Zeropoint Series Setting the New Standard in Advanced Chiller
More informationDiode-Pumped Solid-State Blue Lasers
Diode-Pumped Solid-State Blue s 58 BLD Series 58 BSD Series Our diode-pumped solid-state blue lasers provide high power output in a compact air-cooled package. They are ideal for use in semiconductor,
More informationLaser Distance Sensor Type M Analog-Output
Laser Distance Sensor Type M Analog-Output Operating Manual Version 2.3, May 2009 ELAG Elektronik AG l Stegackerstrasse 14 l CH-8409 Winterthur Contents 1. Safety 1.1 Laser safety 1.2 Electrical safety
More informationSurface Mount 905 nm Pulsed Semiconductor Lasers High Power Laser-Diode Family for Commercial Range Finding
DATASHEET Photon Detection Surface Mount 905 nm Pulsed Semiconductor Lasers Near field profile Key Features Multi cavity lasers concentrate emitting source size Quantum well structure High peak pulsed
More informationNLC C61 Air-Cooled Argon-ion Laser
NLC C61 Air-Cooled Argon-ion Laser User s Manual Complete with Operating Instructions for the 9470 and 2270 Power Supply TABLE OF CONTENTS CHAPTER 1: INTRODUCTION 1 CHAPTER 2: LASER SAFETY 2 CENTER FOR
More informationFTIR-OEM IR source, interferometer & detector modules for modular and OEM applications
FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications The ARCoptix FTIR OEM modules have been developed for system integrators and people looking for a custom FTIR measurement
More informationGuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces
Highly Visible Alignment Lasers for Visually Demanding Surfaces The Guideline 2 Range The provides a reliable and robust industrial alignment laser for a wide range applications including the alignment
More informationCCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800
SENSORS & SYSTEMS Authority in Displacement Measurement CCD-Precision high accuracy and resolution compact sensor design 5 khz frequency N ILD 1800 TRIANGULATOI PRINCIPLE OPTO NCDT Intelligent Laser-Optical
More informationControl and Indicating Equipment
VdS Guidelines for Fire Detection and Fire Alarm Systems VdS 2540en Requirements and Test Methods VdS 2450en : 2018-12 (03) Publisher and publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174
More informationLZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12
EN LZR -I30 LASER SCANNERS FOR INDUSTRIAL DOORS max. detection range of 30 ft x 30 ft 75.5667.07 LZR-I30 0509 Page of SAFETY The device contains IR and visible laser diodes. IR laser: wavelength 905nm;
More informationHazard Analysis, Mitigation, and Operating Procedures for (Laser name) Laser
Hazard Analysis, Mitigation, and Operating Procedures for (Laser name) Laser Prepared by: Date: Rev. 6/24/2016 Page 1 of 6 Table of contents Summary of identified hazards and hazards mitigation: 1. General
More informationLZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more
EN LZR -I00/ -I0 LASER SCANNERS for industrial doors I00: max. detection range of 9.9 m x 9.9 m I0: max. detection range of 5.0 m x 5.0 m User s Guide for product version 0600 and more SAFETY The device
More informationNLC 210 Air-Cooled Argon-ion Laser
NLC 210 Air-Cooled Argon-ion Laser User s Manual Complete with Operating Instructions for the 9470 and 2270 Power Supply TABLE OF CONTENTS CHAPTER 1: INTRODUCTION 1 CHAPTER 2: LASER SAFETY 2 CENTER FOR
More informationAnalisi del Focus-shift su sorgenti multikw. Luca Porcelluzzi Ophir Spiricon Europe GmbH
Analisi del Focus-shift su sorgenti multikw Luca Porcelluzzi Ophir Spiricon Europe GmbH Content Content Ophir Spiricon Europe GmbH Beam Characterization Applications Summary 2 Ophir Spiricon Europe GmbH
More informationORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P
ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P Contents Description Data Sheet No. Page Overview P-1.50.001E 117-118 Technical Data SFI-plus P-1.50.002E-1, 2 119-120 Dimensions
More informationTechnical Data Sheet 1.5mm Side Face Infrared LED
Technical Data Sheet 1.5mm Side Face Infrared LED Features High reliability High radiant intensity Peak wavelength λp=940nm 2.54mm Lead spacing Low forward voltage Pb free This product itself will remain
More informationCCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800
SENSORS & SYSTEMS Authority in Displacement Measurement CCD-Precision high accuracy and resolution compact sensor design 5 khz frequency N ILD 1800 TRIANGULATOI PRINCIPLE OPTO NCDT Intelligent Laser-Optical
More informationISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly
INTERNATIONAL STANDARD ISO 22827-1 First edition 2005-10-15 Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Part 1: Laser assembly Essais de réception pour
More informationLaser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)
Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112) The spectral range of lasers vary from a few nanometer up to some hundred micrometers and is mostly
More informationLaboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka
Last Amended on 07.10.2015 Page 1 of 18 I. EMC Test Facility 1. Electrical and Electronic Products, Process Control Devices, Lighting Control Products, Sensing and Control Devices, Electromechanical Products,
More informationOPERATOR S MANUAL. Infinity Series Ceramic CO2 Laser: Models 15XXSB
92-3031 OPERATOR S MANUAL Infinity Series Ceramic CO2 Laser: Models 15XXSB www.iradionlaser.com Table of Contents Table of Contents... 2 Hazard Information... 3 Terms... 3 General Hazards... 4 Label Locations...
More information64 Max IR Thermometer
64 Max IR Thermometer Instructions PN 4861406 January 2017 2017 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective
More informationProduct Tests Report
TO WHOM IT MAY CONCERN Page: 1 of 5 Product name: Model number and description: MIC IP starlight 7000i Product Tests Report MIC-7502-Z30B, PTZ camera 2MP HDR 30x IP68 IK10, black MIC-7502-Z30W, PTZ camera
More informationTEST REPORT IEC , 2 nd Edition Part 1: Equipment classification and requirements
Test Report issued under the responsibility of: TEST REORT IEC 60825-1, 2 nd Edition art 1: Equipment classification and requirements Report Reference No....: EFSH15041135-IE-01-L01 Date of issue...: May
More informationClass 1 laser beam sensor safe for your eyes
1129 PHOTO PHOTO PARTICUR Sensor SERIES Related Information General terms and conditions... F-3 About laser beam... P.193~ guide... P.121~ General precautions... P.19 Conforming to FDA regulations (-11
More information760nm Single mode VCSEL with Peltier Element and Thermistor in TO510
760nm Single mode VCSEL with Peltier Element and Thermistor in TO510 APC11010108xy Features: Laser Enterprise s 760nm VCSELs are designed to meet the requirements for the optical measurement of oxygen
More informationLORAIN CIP 4890/48120 DC Power System
DC Power for Business-Critical Continuity Key Features Compact flexibility provides rectifiers, distribution, and controller in one shelf Constant power delivers more current at lower voltages to meet
More informationTest Report. Report No.: AGC SS01. Attestation of Global Compliance (Shenzhen) Co., Ltd.
age 1 of 14 Test Report Report o.: AGC10737170807SS01 RODUCT DESIGATIO : Laser pointer touch pen BRAD AME : /A MODEL AME : MO8097, MO8193 CLIET : Mid Ocean Brands B.V DATE OF ISSUE : Aug.18, 2017 STADARD(S)
More informationLaser Collimated Beam Sensor
SERIES Laser Collimated Beam Sensor Class 1 Laser Beam Sensor Safe for Your Eyes Marked Conforming to EMC Directive (Excluding LA-C1) Safe Laser Beam This laser collimated beam sensor conforms to the Class
More informationClass 1 laser beam sensor safe for your eyes
113 Sensor SERIES Related Information General terms and conditions... F-7 About laser beam... P.199~ Sensor selection guide... P.1~ General precautions... P.11 PHOTO PHOTO PARTICUR MEASURE ITY panasonic.net/id/pidsx/global
More informationOTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL
OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL Phone: (209) 586-022 (800) 545-022 Fax: (209) 586-026 E-Mail: salessupport@olsontech.com www.olsontech.com OTEB-CO-B (No SNMP) Rev. X7 /7/200 SAFETY WARNINGS
More informationXGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more
EN XGUARD-0/-5 LASER SCANNERS for industrial doors XGUARD-0: max. detection range of 9.9 m x 9.9 m XGUARD-5: max. detection range of 5.0 m x 5.0 m User s Guide for product version 0600 and more SAFETY
More informationOWNERS MANUAL OPERATION GUIDE
OWNERS MANUAL OPERATION GUIDE Built in Redmond Oregon USA www.laserlinemfg.com P/N 1700-0041 REV. 7.24.17 PRODUCT OVERVIEW The GL1700 Laser Guide was designed from the ground up to provide precise start-stop
More informationM7100 Pressure Transducer
SPECIFICATIONS Performance standard on and off highway engine and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless steel wetted surfaces
More informationRules for Intruder Alarm Systems
Rules for Intruder Alarm Systems Opening detectors (Magnetic contacts) Part 1: Requirements VdS 2120en 03/96 (03) Subject 44 1 General; 2 Terms and definitions; 3 Classification 1 General 1.1 Scope These
More informationLORAIN CSP DC Power System
DC Power for Business-Critical Continuity Key Features Compact flexibility provides more space for revenue generating equipment Constant power delivers more current at lower voltages to meet load or recharge
More informationUC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011
UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011 GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) UC INSTRUMENTS GM8036
More informationClass 1 laser beam sensor safe for your eyes
13 Sensor SERIES Related Information General terms and conditions... F-17 About laser beam... P.13~ Sensor selection guide... P.967~ General precautions... P.1 PHOTO PHOTO Conforming to EMC Directive Conforming
More informationMX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA
MX1A and MX1B: Laser Displacement Detection MX1A and MX1B: Laser Displacement Detection Built-in math capabilities available (MX1B only) Digital display on amplifier; easy setting and monitoring (MX1B
More informationTitle: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7
Environmental Health and Safety Manual Policy Number: EH&S 6-8 Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7 PURPOSE: SCOPE: To protect University employees against health
More informationLaser Series. Highly Visible Alignment Lasers For Visually Demanding Surfaces
Guideline Laser Series Highly Visible Alignment Lasers For Visually Demanding Surfaces Red / Green long visible lines Equal brightness across length of the line Uniform Line (no fading at ends of the line)
More informationTechnical Data Sheet 5mm Infrared LED, T-1
Technical Data Sheet 5mm Infrared LED, T-1 Features High reliability 2.54mm lead spacing Low forward voltage Good spectral matching to Si photodetector Pb free The product itself will remain within RoHS
More informationDatasheet: K-22 LO Sensor
Datasheet: K-22 LO Sensor The K- 22 LO is a CO2 sensor module designed to be built- in into stationary ventilation equipment, such as window vent or duct exhaust actuators, serving as a linear transmitter
More informationAgilent 81663A DFB Laser 8165xA Fabry-Perot Lasers
DFB Laser 8165xA Fabry-Perot Lasers Data Sheet Introduction The high power DFB Laser Source modules are best suited for optical amplifier test and DWDM system test applications. The Fabry-Perot Laser Sources
More informationStony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual. EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6
Title: Laser Safety Stony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6 PURPOSE: SCOPE: To protect University
More informationPENALTIES. All imported products are required to meet the same standards as domestic goods. National Safety Requirements. Customs Requirements
1 of 15 Short Course On: Importation Requirements of Laser Products ICALEO 2006 Version 11-01-06wbkgrd Course Topics Discuss the penalties associated with improperly or illegally importing a laser product.
More informationNX8601BF-AA. Data Sheet R08DS0109EJ0100 Rev.1.00 Apr 19, 2013 LASER DIODE DESCRIPTION FEATURES
A Business Partner of Renesas Electronics Corporation. NX8601BF-AA LASER DIODE 1 625 nm InGaAsP MQW-DFB LASER DIODE COAXIAL MODULE FOR OTDR APPLICATION Data Sheet R08DS0109EJ0100 Rev.1.00 DESCRIPTION The
More informationOperating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content
8 Appendix 8.1 Wiring examples...4 8.2 Start configuration...4 8.3 Sensor configuration...4 8.4 Actuator configuration...5 Operating instructions.............pages 1 to 6 Original 9 EU Declaration of conformity
More informationModular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights
Product Overview LED SOLUTIONS COBRA Slim Line lights Intensity: Now up to 2900 klux Design: Slim and compact Field adjustable: focusing distance and diffusers Chip-On-Board: Extreme brightness and high
More informationSonoSelect and SonoSafe energy meters
energy meters 03/2016 Danfoss VUIGB402 1 Danfoss A/S DK-6430 Nordborg Denmark CVR nr.: 20 16 57 15 Telephone: +45 7488 2222 Fax: +45 7449 0949 EC/EU DECLARATION OF CONFORMITY Danfoss A/S Danfoss Energy
More informationCM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications
Cooled 980nm Pump Laser Module Features High output power, >1.0W kink free Fiber Bragg grating stabilization for wavelength locking over the entire operating conditions Hermetically sealed 10pin mini-butterfly
More informationDescription. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1
Description The DFB-1XXX-BF-XX-CW-Fx-Hx-N127 series of Multi-Quantum Well (MQW) Distributed Feedback (DFB) lasers have been designed specifically to satisfy the requirements of the sensor application.
More informationAll pulses < 4Hz (>0.25sec) BLUE>400mW. As measured under IEC measurement conditions for classification.
THUNDERBOLTB NON-INTERLOCKED HOUSING WARNING This unit contains high power laser devices internally. Do not open the laser housing, due to potential exposure to unsafe levels of laser radiation. The laser
More informationCat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE
Cat. N STOP & GO automatic resetting 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat. N (s) : 4 062 88 / 4 062 89 CONTENTS PAGE 1. Description - Use... 1 2. Product
More informationJBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER
JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER JBE LED Dimming Controller for 110V* & 220V/ 240V AC LED Systems Thank you for purchasing high quality
More informationSpecification for Rising Bollards Control System
Traffic Systems and Signing TR 2207 Issue A March 2002 Specification for Rising Bollards Control System Crown Copyright 2002 Applications to reproduce this material should be made to The Controller of
More informationOur photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.
PHOTO DETECTORS BEAM DIAGNOSTICS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER SOLUTIONS POWER DETECTORS ENERGY DETECTORS MONITORS PRESENTATION OVERVIEW OF THE DIFFERENT MODELS
More informationXUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m
Characteristics photo-electric sensor - XUB - thru beam - laser - Sn 100m - 12..24VDC - cable 2m Buy online Complementary Enclosure material Lens material Blind zone Output type Status LED [Us] rated supply
More informationModels S310 & S310D Laser Power and Energy Meters Setup and Operating Procedures
Models S310 & S310D Laser Power and Energy Meters Setup and Operating Procedures Serial Number P/N 10190M Thank you for choosing a Scientech laser power and energy meter. Scientech, an ISO 9001 registered
More informationREA 105 Arc Protection Module. Operator s Manual
REA 105 1MRS 751005-MUM Issued: 20.04.1998 Version: B2/26.5.2000 Checked: Approved: REA 105 We reserve the right to change data without prior notice. Contents: 1. General...4 1.1. Features...4 2. Safety...5
More information2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.
SYNRAD, Inc. 4600 Campus Place Mukilteo, WA 98275 tel 1.425.349.3500 fax 1.425.349.3667 e-mail synrad@synrad.com web www.synrad.com Power Wizard PW-250 Operating Instructions Important Power Wizard power
More informationEVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector
EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR instruction manual Ref No: NISM/EVC-P/03 Date: Jan 2010 Issue: 3 Quality System Certificate No. 041 Assessed to BS EN ISO 9001:2000 NITTAN (UK) LTD. Hipley
More informationUsed as indicators of indicating the Degree, Functions, Positions etc, in electronic instruments
Features Low power consumption High efficiency and low cost Good control and free combinations on the colors of LED lamps Good lock and easy to assembly. Stackable and easy to assembly Stackable vertically
More informationOptical Multitester 500 450 OTDR EMEA & APac Edition Issue 1 Page 1 of 10 Description The 450 OTDR is a PC based state-ofthe-art OTDR designed for field applications. It is a dedicated OTDR which offers
More informationDescription. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications
Description The DFB-XXX-BF-10-EC-Fx-Hx-N126 laser modules are designed for fiber optic sensor applications. The narrow linewidth and the option of using polarization maintaining optical fiber made it specially
More information2 OZONFILT And Bono Zon Ozone Plants
2.4 OZONFILT OZMa P_PMA_OF_0010_SW Ozone plants of the type series OZONFILT OZMa are pressure systems which generate ozone using compressed air or oxygen under medium-frequency high voltage. The electronic
More informationOur photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.
BEAM DIAGNOSTICS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER SOLUTIONS POWER DETECTORS ENERGY DETECTORS MONITORS PRESENTATION OVERVIEW OF THE DIFFERENT MODELS Our photo detectors
More informationLHCb Rich Detectors Control and High Voltage Systems
LHCb Rich Detectors Control and High Voltage Systems Mario Sannino On behalf of LHCb RICH Group Rich 2007 Trieste 19.10.2007 1 Rich 2007 Trieste 19.10.2007 LHCb Rich Detectors Control and High Voltage
More informationAll personnel working in experimental areas at Jefferson Lab must have completed the EH&S Orientation at Jefferson Lab.
1. Introduction Room 206A of the Free-electron laser Facility at Jefferson Lab (hereafter referred to as the Drive Laser Enclosure, or DLE) contains a Class IV laser 1 which drives the IR Demo injector
More informationA214B/SUG/S400-X6 LAMP. Features. Description. Applications. Revision 1. Expired Period: Forever. LifecyclePhase: Low power consumption
Features Low power consumption High efficiency and low cost Good control and free combinations on the colors of LED lamps Good lock and easy to assembly. Stackable and easy to assembly Stackable vertically
More informationFT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series
FT702LT Turbine control wind sensor......gives durability a new meaning FT702LT series Proven High Availability The FT702LT ultrasonic anemometer is the result of FT Technologies 10 years of experience
More informationEU Declaration of Conformity Annex
2017 / 9C1- The conformity of the designated product(s) with the provisions of the European Low Voltage Directive is given by the compliance with the following European Standard(s) or other specifications.
More informationCompressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture
meas. according to ISO 8573 Residual oil content - particles - moisture DS 500 - the intelligent chart recorder of the next generation. The centerpiece of compressed air quality measurement is the chart
More informationElectro Optical Components, Inc Skylane Boulevard, Santa Rosa, CA Toll Free: 855-EOC
Electro Optical Components, Inc. 546 Skylane Boulevard, Santa Rosa, CA 9543 Toll Free: 855-EOC-63 www.eoc-inc.com info@eoc-inc.com PROFILE BEIJING REALLIGHT TECHNOLOGY CO., LTD Address:3rd Floor, #1 Building,
More information/ / 2018
Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) with IP69K protective tube Protected area width (range) 0...10 m OY4xxS UK 704859 / 05 02 / 2018
More informationMore Precision. thicknesssensor // The sensor for precise thickness measurements
More Precision thicknesssensor // The sensor for precise thickness measurements 2 The sensor for precise thickness measurements thicknesssensor - Immediately ready for use due to perfectly harmonized components
More informationCATALOGUE LASER POINTERS
CATALOGUE LASER POINTERS SM.PROX SRL Via della Beverara 13/A - 40131 Bologna - Italy Tel. +39 051 6350755 - Fax +39 051 6353462 Edition October 2014 With the publication of this catalogue all former editions
More informationLASER SAFETY BARRIER
LASER SAFETY BARRIER 5' x 6' Portable Laser Barrier No-Trip Base Design High CW and Pulsed Damage Thresholds SB5X6 All Contents Stored In Base OVERVIEW Features Portable 5' x 6' (1.5 m x 1.8 m) Barrier
More informationI/A Series 716C 1/16 DIN Temperature Controller
Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of
More informationCertificate: _01 / 22 March 2013
Test report: 936/21219384/A of 27 September 2012 Initial certification: 20 July 2012 Expiry date: 19 July 2017 Publication: BAnz AT 05 March 2013 B10, chapter I, No. 1.6 Approved application The tested
More informationG155PU001S. Pigtailed 14-PIN DIL Laser Diode with TEC. FLMS Min. Typ. Max.
G155PU001S TECHNICAL DATA Pigtailed 14-PIN DIL Laser Diode with TEC Features 1 mw 1550 nm MQW Laser Diode Module with cooler 14pin DIL package with single mode fiber output Applications Optical Communication
More informationFT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m
series Fiber type / CMD Self-check feature provided Within detecting distance 40 m with fiber length 2 m Transmitter and receiver as a set; dimensions same for both The sensor is composed of an optical
More informationSENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -
The sensor is designed for frequent washdowns with a corrosion-resistant AISI316L stainless steel case IP69K rated, compliant to test environments like indicated by Diversey and Ecolab. However, all models
More informationDownlight ENCORE DL6 15W 2700K
Downlight ENCORE DL6 15W 2700K Version 1.08 E² Energy Saving Solutions GmbH Industriestrasse 11 D 69234 Dielheim Telephone: +49 (0) 6222 950 6301 Fax: +49 (0) 6222 950 6385 e mail: info@e2powersave.com
More informationLaser & Ultraviolet Light Sources Safety
1. Purpose and Scope Laser & Ultraviolet Light Sources Safety 1.1. This procedure describes methods for the safe use of lasers and ultraviolet light sources. It applies to the use of lasers and ultraviolet
More informationSPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw
SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:
More informationELLA ID. High CRI, High lm/w OptoDrive LED-module
ELLA ID ELLA ID High CRI, High lm/w OptoDrive LED-module Page 2 of 24 Pages for reference: Pages for reference:... 2 Introduction... 3 Short form Characteristics... 4 Wiring diagram:... 6 Accessories to
More informationSonoSelect and SonoSafe Energy Meters
Installation & User Guide Energy Meters 09/2017 Danfoss VUIGB802 1 www.heating.danfoss.com Danfoss A/S DK-6430 Nordborg Denmark CVR nr.: 20 16 57 15 Telephone: +45 7488 2222 Fax: +45 7449 0949 EU DECLARATION
More informationFour channel video link For low cost video transmission
User Manual Four channel video link For low cost video transmission CFO First Mile series consist of fi bre optic modems which provide a high quality and losless video transmission for variety of CCTV
More informationThis is a preview - click here to buy the full publication
TECHNICAL REPORT IEC TR 61000-4-1 Edition 1.0 2016-04 BASIC EMC PUBLICATION Electromagnetic compatibility (EMC) Part 4-1: Testing and measurement techniques Overview of the IEC 61000-4 series INTERNATIONAL
More informationTHE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:
THE HIGH PERFORMANCE LED Luminaire Series for Stairwells, Bathrooms, Passageways, and General Illumination KEY FEATURES INCLUDE: Multiple Color Options Three color options ensure that the new lighting
More informationModel LTN-3R Outdoor Rated Uninterruptible Power System Single Phase
Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase General Specification 550 VA/Watts 1300 VA/Watts 1.0 GENERAL This specification defines the electrical and mechanical characteristics
More informationUltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW
12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes
More information