INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

Size: px
Start display at page:

Download "INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -"

Transcription

1 MARINE CABLES Your Power Partner on the Seas

2 INTRODUCTION We, a member of the Al-Bahja Group of Companies, are an ISO:900:2008 BASEC, UK certified integrated quality producer of LV and MV Cables, Wires& Conductors and 8mm dia. Oxygen Free High Conductivity Continuous Cast Copper Rods based in the Sultanate of Oman. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -» Shipboard» Onshore/Offshore (NEK 606)» Instrumentation» Fire Resistant» Railway &Signalling» Fire Alarm» Mining» LSOH/LSF» Power & Control» Specialty & Custom MV Cables up to 33KV Nuhas Oman Cables & Wires are type tested by British Standard Institute, U.K.,KEMA, Netherlands,ULand DNV, Norway confirming to relevant BS, IEC and other International Specifications. Nuhas is the first and only producer in the Middle East to have been certified by DNV, Norway capable of manufacturing power, control and instrumentation cables forshipboard, high speed/light craft and off-shore/on-shore applications. Our Offshore and Marine Cables - Your Power Partner On The Seas - are capable of operating under the harshest climatic conditions at all times due to their unique characteristic features flame retardance, oil and mud resistant, crush and impact resistant, enhanced flexibility and resistance to moisture, petrochemical fluids, abrasion, oil and sunlight. The cables comply with the global cable industry standards, IEC for electric installations in ships and requirements of IEC , IEC , and IEC & NEK TS 606 for the marine and offshore/onshore applications and are type tested by DNV, Norway. Our cables are ROHS compliant. New Product Developments are a continuing feature at Nuhas Oman and the diverse product range includes cables for special and complex applications produced by adopting latest production technologies and special materials to cater to the everchanging customer requirements.

3 Quality assurance is the prime driving force behind the Company s operations. Our quality cycle encompasses raw material sourcing, in-process production controls andcertification of finished goods. We are committed to excellence in the management of health, safety, environment and labor practices and to promoting and protecting the welfare of our employees through Safety First work practices. Nuhas also ensures compliance with the laws and regulations of the land.it is our endeavor to be a responsible corporate citizen and contribute to the community through various Corporate Social Responsibility initiatives. Our range of Cable products meet the requirements of a broad spectrum of applications including - Ship Building, Offshore Platforms, FPS, FPSO, Petrochemical, Oil & Gas, Aeronautical, Building & Construction, Instrumentation, Hospitals, Hotels,Industrial, Power & Distribution, Entertainment & Security etc. Our global client base extending from Far East Asia, Indian sub-continent, the GCC, Africa to Europe is testimony to customer confidence and satisfaction. The company is committed to meet the challenges of the Domestic& Global markets for supply of world class Cables &Wires, while maintaining the sanctity of our pristine environment. Index page A. Power & Control Cables. TFOI 0.6/ kv BFOI 0.6/ kv TI 0.6/ kv BI 0.6/ kv 4-7 B. Instrumentation Cables. TFOI(i) 250 V TFOI(c) 250 V BFOI(i) 250 V BFOI(c) 250 V C. General Cable Technical Data & Rating Factors 2 3

4 Flame retardant, Halogen-free, Low smoke Armoured Cable TFOI 0.6/ kv Flame retardant, Halogen-free, Low smoke Armoured Cable TFOI 0.6/ kv Construction Voltage Grade Operating temperature : 90 C : CU/XLPE/CWB/SHF : 0.6/.0 (.2) kv Applicable standards : IEC , IEC IEC for Conductor IEC for Insulation & Sheath Special Properties: Flame retardant : As per IEC & IEC /Cat.A Low smoke : As per IEC & -2 Halogen free : As per IEC & -2 Construction Details: Classification Code Details Conductor Annealed Plain Copper, round shaped, class 2 Insulation T 2 Cross-linked Polyethylene, XLPE Lay up Cores laid up in concentric layers Fillers may be applied to make cable circular Suitable tape(s) may be applied Inner covering F 3 Halogen free compound type SHF Armour O 4 Copper wire braid armour sheath I 5 Halogen free compound type SHF sheath colour Black Core Identification: No. of cores Without earth core With earth core C Black - 2C Blue, Brown - 3C Brown, Black, Grey Yellow-green, Blue, Brown 4C Blue, Brown, Black, Grey Yellow-green, Brown, Black, Grey 5C Blue, Brown, Black, Grey, Black Yellow-green, Blue, Brown, Black, Grey 6C & above White with black colour number marking Note:. Tinned copper conductor can be supplied on request. 2. Tinned copper wire braid can be supplied on request. 3. Other colour of insulation & outer sheath can be provided as per customer requirement Dia over No. Inner inner Braid wire sheath Overall Weight of Conductor Insulation covering covering, diameter thickness, diameter, of cable, cores Size thickness thickness approx nominal approx approx No. mm 2 mm mm mm mm mm mm kg/km

5 Flame retardant, Halogen-free, Low smoke Armoured Cable TFOI 0.6/ kv Fire Resistant, Flame retardant, Halogen-free, Low smoke Armoured Cable BFOI 0.6/ kv Dia over No. Inner inner Braid wire sheath Overall Weight of Conductor Insulation covering covering, diameter thickness, diameter, of cable, cores Size thickness thickness approx nominal approx approx No. mm 2 mm mm mm mm mm mm kg/km Construction Voltage Grade Operating temperature : 90 C : CU/MGT/XLPE/CWB/SHF : 0.6/.0 (.2) kv Applicable standards : IEC , IEC IEC for Conductor IEC for Insulation & Sheath Special Properties: Fire resistant : As per IEC 6033 Flame retardant : As per IEC & IEC /Cat.A Low smoke : As per IEC & -2 Halogen free : As per IEC & -2 Construction Details: Classification Code Details Conductor Annealed Plain Copper, round shaped, class 2 Insulation B 2 3 Mica glass tape + Cross-linked Polyethylene, XLPE Lay up Cores laid up in concentric layers Fillers may be applied to make cable circular Suitable tape(s) may be applied Inner covering F 4 Halogen free compound type SHF Armour O 5 Copper wire braid armour sheath I 6 Halogen free compound type SHF sheath colour Black Core Identification: No. of cores Without earth core With earth core C Black - 2C Blue, Brown - 3C Brown, Black, Grey Yellow-green, Blue, Brown 4C Blue, Brown, Black, Grey Yellow-green, Brown, Black, Grey 5C Blue, Brown, Black, Grey, Black Yellow-green, Blue, Brown, Black, Grey 6C & above White with black colour number marking - Note:. Tinned copper conductor can be supplied on request. 2. Tinned copper wire braid can be supplied on request. 3. Other colour of insulation & outer sheath can be provided as per customer requirement

6 Fire Resistant, Flame retardant, Halogen-free, Low smoke Armoured Cable BFOI 0.6/ kv Fire Resistant, Flame retardant, Halogen-free, Low smoke Armoured Cable BFOI 0.6/ kv Dia over No. Inner inner Braid wire sheath Overall Weight of Conductor Insulation covering covering, diameter thickness, diameter, of cable, cores Size thickness thickness approx nominal approx approx No. mm 2 mm mm mm mm mm mm kg/km Dia over No. Inner inner Braid wire sheath Overall Weight of Conductor Insulation covering covering, diameter thickness, diameter, of cable, cores Size thickness thickness approx nominal approx approx No. mm 2 mm mm mm mm mm mm kg/km

7 Flame retardant, Halogen-free, Low smoke Unarmoured Cable TI 0.6/ kv Construction Voltage Grade Operating temperature : 90 C : CU/XLPE/SHF : 0.6/.0 (.2) kv Applicable standards : IEC , IEC IEC for Conductor IEC for Insulation & Sheath Special Properties: Flame retardant : As per IEC & IEC /Cat.A Low smoke : As per IEC & -2 Halogen free : As per IEC & -2 Construction Details: Classification Code Details Conductor Annealed Plain Copper, round shaped, class 2 Insulation T 2 Cross-linked Polyethylene, XLPE Lay up Core Identification: No. of cores Without earth core With earth core C Black - 2C Blue, Brown - 3C Brown, Black, Grey Yellow-green, Blue, Brown 4C Blue, Brown, Black, Grey Yellow-green, Brown, Black, Grey 5C Blue, Brown, Black, Grey, Black Yellow-green, Blue, Brown, Black, Grey 6C & above White with black colour number marking - Cores laid up in concentric layers Fillers may be applied to make cable circular Suitable tape(s) may be applied sheath I 3 Halogen free compound type SHF sheath colour Black 2 3 Flame retardant, Halogen-free, Low smoke Unarmoured Cable TI 0.6/ kv No. sheath Overall Weight of Conductor Insulation thickness, diameter, of cable, cores Size thickness nominal approx approx No. mm 2 mm mm mm kg/km Note:. Tinned copper conductor can be supplied on request. 2. Other colour of insulation & outer sheath can be provided as per customer requirement. 0

8 Flame retardant, Halogen-free, Low smoke Unarmoured Cable TI 0.6/ kv Flame retardant, Halogen-free, Low smoke Unarmoured Cable TI 0.6/ kv No. sheath Overall Weight of Conductor Insulation thickness, diameter, of cable, cores Size thickness nominal approx approx No. mm 2 mm mm mm kg/km No. sheath Overall Weight of Conductor Insulation thickness, diameter, of cable, cores Size thickness nominal approx approx No. mm 2 mm mm mm kg/km

9 Fire resistant, Flame retardant, Halogen-free, Low smoke Unarmoured Cable BI 0.6/ kv Construction Voltage Grade Operating temperature : 90 C : CU/MGT/XLPE/SHF : 0.6/.0 (.2) kv Applicable standards : IEC , IEC IEC for Conductor IEC for Insulation & Sheath Special Properties: Fire resistant : As per IEC 6033 Flame retardant : As per IEC & IEC / Cat.A Low smoke : As per IEC & -2 Halogen free : As per IEC & -2 Construction Details: Classification Code Details Conductor Annealed Plain Copper, round shaped, class 2 Insulation B 2 3 Mica glass tape + Cross-linked Polyethylene, XLPE Lay up Cores laid up in concentric layers Fillers may be applied to make cable circular Suitable tape(s) may be applied sheath I 4 Halogen free compound type SHF sheath colour Black Core Identification: Fire resistant, Flame retardant, Halogen-free, Low smoke Unarmoured Cable BI 0.6/ kv No. sheath Overall Weight of Conductor Insulation thickness, diameter, of cable, cores Size thickness nominal approx approx No. mm 2 mm mm mm kg/km No. of cores Without earth core With earth core C Black - 2C Blue, Brown - 3C Brown, Black, Grey Yellow-green, Blue, Brown 4C Blue, Brown, Black, Grey Yellow-green, Brown, Black, Grey 5C Blue, Brown, Black, Grey, Black Yellow-green, Blue, Brown, Black, Grey 6C & above White with black colour number marking - Note:. Tinned copper conductor can be supplied on request. 2. Other colour of insulation & outer sheath can be provided as per customer requirement. 4 5

10 Fire resistant, Flame retardant, Halogen-free, Low smoke Unarmoured Cable BI 0.6/ kv Fire resistant, Flame retardant, Halogen-free, Low smoke Unarmoured Cable BI 0.6/ kv No. sheath Overall Weight of Conductor Insulation thickness, diameter, of cable, cores Size thickness nominal approx approx No. mm 2 mm mm mm kg/km No. sheath Overall Weight of Conductor Insulation thickness, diameter, of cable, cores Size thickness nominal approx approx No. mm 2 mm mm mm kg/km

11 INSTRUMENTATION CABLES Flame retardant, Halogen-free, Low smoke Individually Screened Armoured Cable TFOI(i) 250 V INSTRUMENTATION CABLES Flame retardant, Halogen-free, Low smoke Individually Screened Armoured Cable TFOI(i) 250 V Construction Voltage Grade Operating temperature : 90 C : CU/XLPE/ISCR/CWB/SHF : 50/250 (300) V Applicable standards : IEC , IEC IEC for Conductor, CR to Table 6 of IEC IEC for Insulation & Sheath Special Properties: Flame retardant : As per IEC & IEC / Cat.A Low smoke : As per IEC & -2 Halogen free : As per IEC & -2 Construction Details: Classification Code Details Conductor Annealed Plain Copper, round shaped, class 2 Insulation T 2 Cross-linked Polyethylene, XLPE Twisting Two insulated cores twisted together to form a pair Individual screening (i) 3 Aluminium backed polyester tape screening with tinned copper drain wire Lay up Screened pairs laid up in concentric layers and wrapped in polyester tape. Inner covering F 4 Halogen free compound type SHF Armour O 5 Copper wire braid armour sheath I 6 Halogen free compound type SHF sheath colour Grey Core Identification: Pairs : Black, White Note:. Tinned copper conductor can be supplied on request. 2. Tinned copper wire braid can be supplied on request. 3. Other colour of insulation & outer sheath can be provided as per customer requirement Dia over No. Inner inner Braid wire sheath Overall Weight of Conductor Insulation covering covering, diameter thickness, diameter, of cable, cores Size thickness thickness approx nominal approx approx No. mm 2 mm mm mm mm mm mm kg/km P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P

12 INSTRUMENTATION CABLES Flame retardant, Halogen-free, Low smoke Collectively Screened Armoured Cable TFOI(c) 250 V INSTRUMENTATION CABLES Flame retardant, Halogen-free, Low smoke Collectively Screened Armoured Cable TFOI(c) 250 V Construction Voltage Grade Operating temperature : 90 C : CU/XLPE/OSCR/CWB/SHF : 50/250 (300) V Applicable standards : IEC , IEC IEC for Conductor, CR to Table 6 of IEC IEC for Insulation & Sheath Special Properties: Flame retardant : As per IEC & IEC / Cat.A Low smoke : As per IEC & -2 Halogen free : As per IEC & -2 Construction Details: Classification Code Details Conductor Annealed Plain Copper, round shaped, class 2 Insulation T 2 Cross-linked Polyethylene, XLPE Twisting Two insulated cores twisted together to form a pair Lay up Twisted pairs laid up in concentric layers Collective screening (c) 3 Aluminium backed polyester tape screening with tinned copper drain wire Inner covering F 4 Halogen free compound type SHF Armour O 5 Copper wire braid armour sheath I 6 Halogen free compound type SHF sheath colour Grey Core Identification: Pairs : Black, White Note:. Tinned copper conductor can be supplied on request. 2. Tinned copper wire braid can be supplied on request. 3. Other colour of insulation & outer sheath can be provided as per customer requirement Dia over No. Inner inner Braid wire sheath Overall Weight of Conductor Insulation covering covering, diameter thickness, diameter, of cable, cores Size thickness thickness approx nominal approx approx No. mm 2 mm mm mm mm mm mm kg/km 2P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P

13 INSTRUMENTATION CABLES Fire resistant, Flame retardant, Halogen-free, Low smoke Individually Screened Armoured Cable BFOI(i) 250 V INSTRUMENTATION CABLES Fire resistant, Flame retardant, Halogen-free, Low smoke Individually Screened Armoured Cable BFOI(i) 250 V Construction Voltage Grade Operating temperature : 90 C : CU/MGT/XLPE/ISCR/CWB/SHF : 50/250 (300) V Applicable standards : IEC , IEC IEC for Conductor, CR to Table 6 of IEC IEC for Insulation & Sheath Special Properties: Fire resistant : As per IEC 6033 Flame retardant : As per IEC & IEC /Cat.A Low smoke : As per IEC & -2 Halogen free : As per IEC & -2 Construction Details: Classification Code Details Conductor Insulation Twisting B 2 3 Annealed Plain Copper, round shaped, class 2 Mica glass tape + Cross-linked Polyethylene, XLPE Two insulated cores twisted together to form a pair Individual screening (i) 4 Aluminium backed polyester tape screening with tinned copper drain wire Lay up Screened pairs laid up in concentric layers and wrapped in polyester tape. Inner covering F 5 Halogen free compound type SHF Armour sheath O I 6 7 Copper wire braid armour Halogen free compound type SHF sheath colour Grey Core Identification: Pairs : Black, White Note:. Tinned copper conductor can be supplied on request. 2. Tinned copper wire braid can be supplied on request. 3. Other colour of insulation & outer sheath can be provided as per customer requirement Dia over No. Inner inner Braid wire sheath Overall Weight of Conductor Insulation covering covering, diameter thickness, diameter, of cable, cores Size thickness thickness approx nominal approx approx No. mm 2 mm mm mm mm mm mm kg/km P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P

14 INSTRUMENTATION CABLES Fire resistant, Flame retardant, Halogen-free, Low smoke Collectively Screened Armoured Cable BFOI(c) 250 V INSTRUMENTATION CABLES Fire resistant, Flame retardant, Halogen-free, Low smoke Collectively Screened Armoured Cable BFOI(c) 250 V Construction Voltage Grade Operating temperature : 90 C : CU/MGT/XLPE/OSCR/CWB/SHF : 50/250 (300) V Applicable standards : IEC , IEC IEC for Conductor, CR to Table 6 of IEC IEC for Insulation & Sheath Special Properties: Fire resistant : As per IEC 6033 Flame retardant : As per IEC & IEC /Cat.A Low smoke : As per IEC & -2 Halogen free : As per IEC & -2 Construction Details: Classification Code Details Conductor Annealed Plain Copper, round shaped, class 2 Insulation B 2 3 Mica glass tape + Cross-linked Polyethylene, XLPE Twisting Two insulated cores twisted together to form a pair Lay up 4 Twisted pairs laid up in concentric layers Collective screening (c) Aluminium backed polyester tape screening with tinned copper drain wire Inner covering F 5 Halogen free compound type SHF Armour O 6 Copper wire braid armour sheath I 7 Halogen free compound type SHF sheath colour Grey Core Identification: Pairs : Black, White Note:. Tinned copper conductor can be supplied on request. 2. Tinned copper wire braid can be supplied on request. 3. Other colour of insulation & outer sheath can be provided as per customer requirement Dia over No. Inner inner Braid wire sheath Overall Weight of Conductor Insulation covering covering, diameter thickness, diameter, of cable, cores Size thickness thickness approx nominal approx approx No. mm 2 mm mm mm mm mm mm kg/km 2P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P

15 GENERAL GENERAL CABLE CABLE TECHNICAL DATA DATA & RATING FACTORS & RATING FACTORS TECHNICAL DATA Power Cables Continuous Current Ratings Installation Conditions Ambient air temperature : 45 C Conductor temperature : 90 C Conductor size Single core Two core Three, Four & Five core mm 2 A A A Correction factors for various ambient air temperatures Ambient air temperatures Correction factors 25 C C.6 35 C. 40 C C C C

16 TECHNICAL DATA Electrical Characteristics of Power & Control Cables TFOI 0.6/ kv TECHNICAL DATA Electrical Characteristics of Power & Control Cables TI 0.6/ kv Conductor Max DC rest. AC rest. of Capacitance Reactance at 50 Hz, approx Short circuit Size of conductor conductor at per core, Single core rating for at 20 C 90 C, approx approx in trefoil Multi core sec mm 2 Ω/km Ω/km µf/km Ω/km Ω/km ka Conductor Max DC rest. AC rest. of Capacitance Reactance at 50 Hz, approx Short circuit Size of conductor conductor at per core, Single core rating for at 20 C 90 C, approx approx in trefoil Multi core sec mm 2 Ω/km Ω/km µf/km Ω/km Ω/km ka BFOI 0.6/ kv Conductor Max DC rest. AC rest. of Capacitance Reactance at 50 Hz, approx Short circuit Size of conductor conductor at per core, Single core rating for at 20 C 90 C, approx approx in trefoil Multi core sec mm 2 Ω/km Ω/km µf/km Ω/km Ω/km ka BI 0.6/ kv Conductor Max DC rest. AC rest. of Capacitance Reactance at 50 Hz, approx Short circuit Size of conductor conductor at per core, Single core rating for at 20 C 90 C, approx approx in trefoil Multi core sec mm 2 Ω/km Ω/km µf/km Ω/km Ω/km ka

17 This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. If any person suffers loss or damage which is proved to have been caused by any negligent act or omission of Det Norske Veritas, then Det Norske Veritas shall pay compensation to such person for his proved direct loss or damage. However, the compensation shall not exceed an amount equal to ten times the fee charged for the service in question, provided that the maximum compensation shall never exceed USD 2 million. In this provision "Det Norske Veritas" shall mean the Foundation Det Norske Veritas as well as all its subsidiaries, directors, officers, employees, agents and any other acting on behalf of Det Norske Veritas. This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. If any person suffers loss or damage which is proved to have been caused by any negligent act or omission of Det Norske Veritas, then Det Norske Veritas shall pay compensation to such person for his proved direct loss or damage. However, the compensation shall not exceed an amount equal to ten times the fee charged for the service in question, provided that the maximum compensation shall never exceed USD 2 million. In this provision "Det Norske Veritas" shall mean the Foundation Det Norske Veritas as well as all its subsidiaries, directors, officers, employees, agents and any other acting on behalf of Det Norske Veritas. TECHNICAL DATA Electrical Characteristics of Instrumentation Cables DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE TYPE APPROVAL CERTIFICATE This is to certify: Certificate No: E-3644 File No: Job Id: TYPE APPROVAL CERTIFICATE This is to certify: Certificate No: E-3645 File No: Job Id: CERTIFICATE NO. E-2237 That the Electric Power Cable That the Electric Power Cable This is to certify that the Low Voltage Cable with type designation(s) RFOU P 0,6/kV, RFOU P/P8 0,6/ kv with type designation(s) BFOU P5 0,6/kV, BFOU P5/P2 0,6/ kv Conductor size Max DC resistance of Max mutual capacitance Max L/R ratio conductor at 20 C mm2 Ω/km nf/km µh/ω with type designation(s) BFOU (c) S4/S8 250 V, BFOU (i+c) S3/S7 250 V Manufactured by Nuhas Oman LLC Sultanate of Oman, Oman is found to comply with Det Norske Veritas' Rules for Classification of Ships, High Speed & Light Craft and Det Norske Veritas' Offshore Standards IEC ( ) IEC (999-04) IEC ( ) IEC /2 (20-) IEC ( ) NEK TS 606 ( ) Application Instrumentation and communication. Fire resistant. Flame retardant Cat. A. Halogen free. Low smoke. Mud resistant. Cold bend & cold impact -40C. Type Voltage class (V) Temp. class ( C) BFOU (c) S4/S8 250 V BFOU (i+c) S3/S7 250 V This Certificate is valid until Issued at H vik on for Det Norske Veritas AS DNV local station: Dubai Approval Engineer: Ivar Bull Marit Laumann Head of Section Issued to Nuhas Oman LLC Sultanate of Oman, Oman is found to comply with Det Norske Veritas' Rules for Classification of Ships, High Speed & Light Craft and Det Norske Veritas' Offshore Standards IEC (20-08) IEC ( ) IEC /2 (20-) IEC6034-/2 ( / ) NEK TS 606 ( ) Application : General power and lighting. Flame retardant in bunch Cat. A. Halogen free. Low smoke. Mud resistant. Cold bend -40 C / Cold impact -35 C. Type Voltage class (kv) Temp. class ( C) RFOU 0,6/ 90 P 0,6/kV RFOU P/P8 0,6/ 0,6/ 90 kv This Certificate is valid until Issued at H vik on DNV GL local station: New Building Dubai Approval Engineer: Ivar Bull for DNV GL Marit Laumann Head of Section This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. If any person suffers loss or damage which is proven to have been caused by any negligent act or omission of the Society, then the Society shall pay compensation to such person for his proven direct loss or damage. However, the compensation shall not exceed an amount equal to ten times the fee charged for the service in question. The maximum compensation shall never exceed USD 2 million. In this provision the Society shall mean DNV GL AS as well as all its direct and indirect owners, affiliates, subsidiaries, directors, officers, employees, agents and any other person or entity acting on behalf of DNV GL AS. Issued to Nuhas Oman LLC Sultanate of Oman, Oman is found to comply with Det Norske Veritas' Rules for Classification of Ships, High Speed & Light Craft and Det Norske Veritas' Offshore Standards IEC (20-08) IEC (999-04) IEC ( ) IEC /2 (20-) IEC6034-/2 ( / ) NEK TS 606 ( ) Application : General power and lighting. Fire resistant. Flame retardant in bunch Cat. A. Halogen free. Low smoke. Mud resistant. Cold bend -40 C / Cold impact -35 C. Type Voltage class (kv) Temp. class ( C) BFOU 0,6/ 90 P5 0,6/kV BFOU P5/P2 0,6/ 0,6/ 90 kv This Certificate is valid until Issued at H vik on DNV GL local station: New Building Dubai Approval Engineer: Ivar Bull for DNV GL Marit Laumann Head of Section This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. If any person suffers loss or damage which is proven to have been caused by any negligent act or omission of the Society, then the Society shall pay compensation to such person for his proven direct loss or damage. However, the compensation shall not exceed an amount equal to ten times the fee charged for the service in question. The maximum compensation shall never exceed USD 2 million. In this provision the Society shall mean DNV GL AS as well as all its direct and indirect owners, affiliates, subsidiaries, directors, officers, employees, agents and any other person or entity acting on behalf of DNV GL AS. DET NORSKE VERITAS AS, Veritasveien, NO-322 H vik, Norway, Tel.: , Org.No. NO MVA. Form No.: TA 4a Issue: December 202 Page of 3 Form code: TA 4a Revision: Page of 3 DNV GL 204. DNV GL and the Horizon Graphic are trademarks of DNV GL AS. Form code: TA 4a Revision: Page of 3 DNV GL 204. DNV GL and the Horizon Graphic are trademarks of DNV GL AS. Installation Guide Minimum bending radius During Installation For fixed installation DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. E-2236 This is to certify that the Low Voltage Cable 8 x O.D. 6 x O.D. with type designation(s) RFOU (c) S2/S6 250 V, RFOU (i+c) S/S5 250V Manufactured by Nuhas Oman LLC Sultanate of Oman, Oman Pulling tension (pulling eye on conductor) is found to comply with Det Norske Veritas' Rules for Classification of Ships, High Speed & Light Craft and Det Norske Veritas' Offshore Standards IEC ( ) IEC ( ) IEC /2 (20-) IEC ( ) NEK TS 606 ( ) Application 70 N/mm2 Instrumentation and communication. Flame retardant Cat. A. Halogen free. Low smoke. Mud resistant. Cold bend & cold impact -40C. Minimum temperature of installation Type Voltage class (V) Temp. class ( C) RFOU (c) S2/S6 250 V RFOU (i+c) S/S5 250V This Certificate is valid until C Issued at H vik on DNV local station: Dubai Approval Engineer: Ivar Bull for Det Norske Veritas AS Marit Laumann Head of Section DET NORSKE VERITAS AS, Veritasveien, NO-322 H vik, Norway, Tel.: , Org.No. NO MVA. Form No.: TA 4a Issue: December 202 Page of 3 Achieving Milestones 30 3

18 NUHAS OMAN LLC P O Box 86, Postal Code 24, Rusayl Industrial Estate, Sultanate of Oman Tel.: , , Fax: marketing@nuhasoman.com, Website: (A Member of the Al Bahja Group) AN ISO 900: 2008 COMPANY

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd. Flexflame Arctic Grade Cables for Extreme Conditions Photo: Sakhalin Energy Investement Company Ltd. Linking the future Draka Norsk Kabel is a part of Prysmian Group, a worldwide leader in the cable industry.

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE TYPE APPROVAL CERTIFICATE Certificate No: TAE00000GG Revision No: 2 This is to certify: That the Data transmission cables and systems with type designation(s) MGD Cat 3, MGD Cat 5, Cat 5e, MGD cat 6, Cat

More information

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Flame Retardant Overall Screened Instrumentation Cables (multicore) Flame Retardant Overall Screened Instrumentation Cables (multicore) RE-2X(St)H RE-2X(St)HSWAH LSZH Outer Sheath Tinned Copper Drain Wire LSZH Inner Sheath XLPE Insulation Plain Annealed Copper Aluminium/polyester

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE TYPE APPROVAL CERTIFICATE Certificate No: E-13480 File No: 822.21 Job Id: 262.1-008042-6 This is to certify: That the Frequency Converter with type designation(s) Emotron FDU 2.0 Issued to CG Drives &

More information

PRODUCT CATALOGUE Norröna

PRODUCT CATALOGUE  Norröna PRODUCT CATALOGUE Norröna WWW.SCANKAB.COM Table of contents MARINE AND OFFSHORE CABLES 1 TOXFREE XZ1-K (AS) - 0.6/1 kv 1 TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V 5 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 -

More information

DNVGL-CP-0399 Edition March 2016

DNVGL-CP-0399 Edition March 2016 CLASS PROGRAMME Type approval DNVGL-CP-0399 Edition March 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

Fire Resistant Cables

Fire Resistant Cables Fire Resistant Cables Ducab (Abu Dhabi) Factory P.O. Box 9171, Abu Dhabi, UAE Tel: (971-2) 502 7777 Fax: (971-2) 502 7888 email: ducab@ducab.com Ducab Connect P.O. Box 11529, Dubai, United Arab Emirates

More information

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class ) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V Class ) PVC Outer Sheath Plain Annealed

More information

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) Caledonian Flame Retardant Power & Control Cables www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/DSTA/LSZH

More information

DNVGL-CP-0401 Edition February 2016

DNVGL-CP-0401 Edition February 2016 CLASS PROGRAMME Type approval DNVGL-CP-0401 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

Shipboard & Offshore Cables

Shipboard & Offshore Cables Shipboard & Offshore Cables Shipboard & Offshore Cables Páge Introduction 3 Power Cables XL / XL-FR 5 XC4L / XC4L-FR 6 XLC4L / XLC4L-FR 7 Instrumentation cables XHL / XHL-FR 8 XOL / XOL-FR 9 XHC4L / XHC4L-FR

More information

Introduction.

Introduction. Introduction The safety of occupants and users of public, commercial and industrial premises is of paramount importance. One important safety feature is the appropriate use of fire performance cables for

More information

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2 FLAME-X 950 TELE-FONIKA KABLE SA (DMCC Branch). Table of Contents is the Regional Middle East Sales Office of Tele-Fonika Kable S.A. from Poland, 4-th largest manufacturer of electric cables and wires

More information

FIRE RESISTANT CABLES FP300

FIRE RESISTANT CABLES FP300 FIRE RESISTANT CABLES FP300 Fire resistant LSOH power cables for fixed wiring FIRE RESISTANT CABLES FP300 LPCB Ref No: 077e/01 FP300 > Prysmian FP300 is designed for cabling essential safety circuits associated

More information

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

OFFSHORE CABLES.   Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain Top Cable Central Headquarters Leonardo Da Vinci, number 1 08191 Rubí (Barcelona) Spain OFFSHORE CABLES Tel +4 9 586 21 78 +4 9 586 21 68 Fax +4 9 586 21 65 sales@topcableoffshoremarine.com http://www.topcableoffshoremarine.com

More information

High Performance LSZH Fire Resistant Cable

High Performance LSZH Fire Resistant Cable High Performance LSZH Fire Resistant Cable www.cavicel.com 104/2 FIRECEL SR 114H is the long and well established CAVICEL fire resistant cable in the market, since many years. These cables are third party

More information

UNIKA Universal Cable Cable Specialist

UNIKA Universal Cable Cable Specialist UNIKA Universal Cable Cable Specialist Committed to Quality At ÜNİKA, quality is an intrinsic part of our Operations. Our comprehensive product and System certification not only are mandatory requirements

More information

DNVGL-CP-0402 Edition February 2016

DNVGL-CP-0402 Edition February 2016 CLASS PROGRAMME Type approval DNVGL-CP-0402 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

BS /1000V XLPE Insulation LSZH Sheath Cables

BS /1000V XLPE Insulation LSZH Sheath Cables BS 8573 600/1000V XLPE Insulation LSZH Sheath Cables Caledonian www.addison-cables.com Company Profile Caledonian & Addison, branded under Caledoniea & Addimax, established in 1978, offers one of the most

More information

GROUNDING AVOIDANCE SYSTEM (GAS)

GROUNDING AVOIDANCE SYSTEM (GAS) STANDARD FOR CERTIFICATION No. 2.9 GROUNDING AVOIDANCE SYSTEM (GAS) JANUARY 2003 Veritasveien 1, N-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD is an autonomous and independent

More information

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. ADDISON Flame Retardant RG59 B/U Coaxial cables Plain copper wire braid PE Solid Bare Copper PVC Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring

More information

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax: STANDARD FOR CERTIFICATION No. 2.9 RADAR REFLECTOR JANUARY 2003 Veritasveien 1, N-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD is an autonomous and independent Foundation with

More information

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7 CONTENTS Page Introduction... 1 Customer Service... 2 BS codes of practice BS 8519... 5 Fire Performance Cable Selection Guide... 7 FlamBICC Introduction...8 FlamBICC 1...10 FlamBICC 2...12 FlamBICC 3...14

More information

Caledonian Flame Retardant Coaxial Cables

Caledonian Flame Retardant Coaxial Cables Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant RG59 Coaxial cables LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape

More information

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Draka, the world s mo When it comes to specifying fire performance cables, zero halogen building wires and power cables, you have to choose products

More information

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Draka, the world s most trusted cable brand When it comes to specifying fire performance cables, zero halogen building wires and power cables, you have

More information

DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE

DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. A-10733 This Certificate consists of 7 pages This is to certify that the Diesel engine safety, control and alarm system with type designations

More information

LV FIRE RESISTANT CABLES

LV FIRE RESISTANT CABLES LV FIRE RESISTANT CABLES CONTENTS 3 GENERAL INTRODUCTION LV FIRE RESISTANT CABLES TECHNICAL INFORMATION 4 9 12 24 26 GENERAL CABLE STRUCTURE ELECTRICAL CHARACTERISTICS CURRENT RATING VOLTAGE DROP SHORT

More information

FIRE RESISTANT CABLES

FIRE RESISTANT CABLES Conducting Value The Last Cable Standing FIRE RESISTANT CABLES 100/7b ISO 9001:2008 Certificate No. CS1-249 MANAGEMENT SYSTEMS Assessed to ISO 9001:2008 Cert/LPCB ref. 217 GOST ISO 9001-2011 (ISO 9001:2008)

More information

QUALITY THROUGH EXPERIENCE

QUALITY THROUGH EXPERIENCE QUALITY THROUGH EXPERIENCE Brief History of ÜNTEL Established in 1972 Partnership of Ünlü and Günan families since then 40 years of manufacturing experience with an extensive production range for various

More information

FIRE RESISTANT CABLES FP200 GOLD

FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1 FP200 GOLD Clause 26.2 > The original highly durable and dressable, easy to terminate and install fire resistant cable. Approved

More information

Caledonian Fire resistant Coaxial Cables

Caledonian Fire resistant Coaxial Cables Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com Fire resistant rg59 b/u Coaxial Cables RG59 B/U FR LSZH Sheath Fire Resistant Tape Copper Clad Steel/Bare Copper

More information

FIRE RESISTANT CABLES FP400

FIRE RESISTANT CABLES FP400 FIRE RESISTANT CABLES FP400 FIRE RESISTANT CABLES FP400 BS7846-F2 CABLE CHARACTERISTICS FP400 APPROVALS INSTALLATION Certificate No 077b Certificate No 517b > Prysmian FP400 is the original fire resistant

More information

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES Cables Limited MADE IN IRELAND SINCE 1934 QUALITY APPROVED CABLES IDH CABLES LIMITED GUARDIANTM MECHANICALLY PROTECTED CABLES The original BS-8436, IS-273 multifunctional, easy to install, connect-and-protect

More information

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by

More information

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index

More information

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB.

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB. Certificate No 077b Certificate No 517b > Prysmian FP400 is the original fire resistant armoured cable providing an easy to install and terminate, robust fire resistant wiring system. In addition to maintaining

More information

FIRE PERFORMANCE CABLE

FIRE PERFORMANCE CABLE FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Double Layer of Aluminium/ Polyester Laminated Tapes / Circuit Protective Conductor

More information

MARINE GYRO COMPASS STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

MARINE GYRO COMPASS STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax: STANDARD FOR CERTIFICATION No. 2.9 MARINE GYRO COMPASS JANUARY 2003 Veritasveien 1, N-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD is an autonomous and independent Foundation

More information

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES CORFLEX TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES INDEX Instrumentation Cables - Pairs and Triads (0V*)... 2 - The Original MC-HL Technology In 1958 Canada Wire and Cable, which s now part of Nexans,

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE TYPE APPROVAL CERTIFICATE Certificate No: E-14378 This is to certify: That the Pilot Device with type designation(s) Pilot device Issued to BARTEC GmbH BAD MERGENTHEIM, Germany is found to comply with

More information

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629) Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Shortest Lead Times Standard 8-10

More information

Catalogue Power Cables

Catalogue Power Cables Catalogue Power Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Power

More information

SHOP PRIMERS FOR CORROSION PROTECTION OF STEEL PLATES AND SECTIONS

SHOP PRIMERS FOR CORROSION PROTECTION OF STEEL PLATES AND SECTIONS STANDARD FOR CERTIFICATION No. 2.9 SHOP PRIMERS FOR CORROSION PROTECTION OF STEEL PLATES AND SECTIONS OCTOBER 2009 Veritasveien 1, NO-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD

More information

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) 600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) FFX400 1SZ1-R(PH60)(CU/SR/LSZH 600/1000V Class 2) FFX400 1SZ1-F(PH60)(CU/SR/LSZH 600/1000V Class 5) Silicone Rubber Insulation Plain

More information

ENHANCED FIRE PERFORMANCE CABLE

ENHANCED FIRE PERFORMANCE CABLE FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Glass Fibre Tape / Tinned Copper Circuit Protective Conductor / Double Layer of Copper/Polyester

More information

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS: PRODUCT DATASHEET & APPLICATIONS GUIDE LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2 ) Additionally tested for

More information

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS: PRODUCT DATASHEET & APPLICATIONS GUIDE BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2 ) Additionally

More information

Catalogue Telecommunication Cables INTRODUCCIÓN

Catalogue Telecommunication Cables INTRODUCCIÓN Catalogue Telecommunication Cables INTRODUCCIÓN Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Conductores Tecnológicos S.A.

More information

FIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation

FIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation FIRE RESISTANT CABLES FP PLUS New Generation Now with enhanced Insudite TM insulation ENHANCED FIRE RESISTANT CABLES FP PLUS BS7629-1:2008 FP PLUS > Certificate No 077g/02 The new generation of FP PLUS

More information

FIRE RESISTANT CABLES FP200 GOLD

FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1:2008 FP200 GOLD FIRE RESISTANT CABLES Key Applications Fire detection and fire alarm systems for buildings Voice alarm systems

More information

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2  Page Power Cables Power Cables Page Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7 ELECWIRES 2 www.elecwires.es INTRODUCTION Power Cables Power cables for electrical installations, domestic & industrial, specifically

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. P-14362 This is to certify that the Ballast Water Management System with type designation(s) NK-O3-BlueBallast Water Management System Manufactured

More information

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES Cables Limited MADE IN IRELAND SINCE 1934 QUALITY APPROVED CABLES IDH CABLES LIMITED FUMEGUARD TM LOW SMOKE HALOGEN FREE CABLES The longest-running original range of low voltage, low smoke, halogen free

More information

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+) Page 1 / 7 Construction and tests. Standards: UNE 211025 Compliance with the Low Voltage Directive (LVD): 2014/35 / EU Construction Products Regulation (CPR) - Regulation (EU) Nº 305/2011: Reaction to

More information

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission ADDISON Flame Retardant CAT5e Data Cables FTX-CAT5e U/UTP4P24 FTX-CAT5e f/utp4p24 FTX-CAT5e sf/utp4p24 LSZH Outer Aluminium/Polyester Tape Solid Copper Conductor PE Insulation Tinned Copper Drain Wire

More information

Photovoltaic Cables EN H1Z2Z2-K

Photovoltaic Cables EN H1Z2Z2-K Photovoltaic Cables EN 50618 H1Z2Z2-K COMPANY PROFILE Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different

More information

Catalogue. Instrumentation & Control Cables

Catalogue. Instrumentation & Control Cables Catalogue Instrumentation & Control Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 Instrumentation VOV 4 VHOV 5 VOVMV 6 VHOVMV 7 Control RV 8 RZ1C3Z1 9 Conductores

More information

LSOH Flexible Cables

LSOH Flexible Cables LSOH Flexible Cables Low Voltage (300/500 V) 3182B, 3183B, 3184B Piresafe TM Flex Cable Approvals Key Applications > Supply leads for medium duty domestic and office appliances, lighting fittings and portable

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ISO/IEC 17065:2012 to provide product conformity certification Presley Way Crownhill Milton Keynes MK8 0ES Contact: Tracie Hunter Tel: +44 (0)1908 267300 Fax: +44 (0)1908 267255 E-Mail: mail@basec.org.uk

More information

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications. FIRE RESISTANT CABLES FP600 FIRE RESISTANT CABLES FP600 BS7346-6 FP600 > Prysmian FP600 is a unique enhanced performance fire resistant power cable, designed specifically to meet the more onerous fire

More information

Tratos Railway Cables

Tratos Railway Cables January 2013 Tratos Railway Cables Cables for a moving world www.tratos.eu Introduction Tratos Cavi is a company specialising in the production of power, signalling, control and telecommunications cables

More information

Lloyd s Register Type Approval System Test Specification Number 3

Lloyd s Register Type Approval System Test Specification Number 3 Working together for a safer world Lloyd s Register Type Approval System Test Specification Number 3 July 2015 Performance Test Specification for Equipment to be used in Marine Applications: Electric Cables

More information

STANDARDS INSTALLATION. Certificate No 077m

STANDARDS INSTALLATION. Certificate No 077m Certificate No 077m > Prysmian FP600 is a unique enhanced performance fire resistant power cable, designed specifically to meet the more onerous fire survival requirements now requested by regulators and

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60092-350 Second edition 2001-06 Electrical installations in ships Part 350: Shipboard power cables General construction and test requirements Installations électriques à bord

More information

Total Fire Solutions. Includes BS 8519 and the updated BS :

Total Fire Solutions. Includes BS 8519 and the updated BS : Total Fire Solutions Includes BS 8519 and the updated BS 5266-1:2011 www.aeicables.co.uk Introduction: Total Fire Solutions Power and control cable systems for life safety and fire-fighting applications

More information

SOUND RECEPTION SYSTEM

SOUND RECEPTION SYSTEM STANDARD FOR CERTIFICATION No. 2.9 SOUND RECEPTION SYSTEM APRIL 2009 Veritasveien 1, NO-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD (DNV) is an autonomous and independent foundation

More information

Power Control Cable Iec

Power Control Cable Iec POWER CONTROL CABLE IEC 60502 1 PDF - Are you looking for power control cable iec 60502 1 Books? Now, you will be happy that at this time power control cable iec 60502 1 PDF is available at our online

More information

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions. Method of test defined in IEC 60331-21 for determining the circuit integrity performance of a cable under fire conditions. WF Report Number: 148371 Test Sponsor: FTC - Fabbrica Trentina Conduttori Srl

More information

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008. BS EN 60332-1-2:2004 Test On Electric And Optical Fibre Cables Under Fire Conditions WF Report Number 177603 Date: 14 th November 2008 Test Sponsor: FTC Fabbrica Trentina Conduttori Srl 0249 Page 2 of

More information

Certificate No PC-NOR-NA This Certificate consists of 6 pages. This is to certify that the product(s) Wireless Intrusion Alarm Equipment

Certificate No PC-NOR-NA This Certificate consists of 6 pages. This is to certify that the product(s) Wireless Intrusion Alarm Equipment DET NORSKE VERITAS CERTIFICATE OF CONFORMITY PRODUCT CERTIFICATION SYSTEM 5 Certificate No. 4609-2014-PC-NOR-NA This Certificate consists of 6 pages This is to certify that the product(s) Wireless Intrusion

More information

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour. 67 POWERFLEX RV-K POWERFLEX RV-K Industrial flexible cable for power transmission. 1 IEC 60502-1 - UNE 21123-2 DESIGN 1. Conductor 2 Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.

More information

Telecommunication Cables

Telecommunication Cables Telecommunication Cables Telecommunication Cables Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Page ELECWIRES 2 www.elecwires.es INTRODUCCIÓN Telecommunication Cables Telephone cables suitable

More information

MED 96/98/EC QUALITY SYSTEM MODULE D CERTIFICATE

MED 96/98/EC QUALITY SYSTEM MODULE D CERTIFICATE Page 1 I 2 Certificate number: SMS.MED.D/92/D.O MARINE DIVISION BUREAU VERITAS Notified Body No 0062 www. veri star.com MED 96/98/EC QUALITY SYSTEM MODULE D CERTIFICATE This certificate is issued under

More information

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V PHOTOVOLTAIC CABLES PHOTOVOLTAIC CABLES INDEX n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1500V....................... 2-3 n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1000V.......................

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61892-4 First edition 2007-06 Mobile and fixed offshore units Electrical installations Part 4: Cables Commission Electrotechnique Internationale International Electrotechnical

More information

Flexible Power Cable DLO

Flexible Power Cable DLO 37-119 Flexible Power Cable DLO 2000 Volts 90 C Diesel Locomotive Cable Limited Smoke (Sizes 2/0 and higher) EP/CPE RHH, RHW-2 Flexible-stranded, tin-coated annealed copper Flame retardant, oil and sunlight

More information

BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions.

BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions. BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions WF Report Number: 147709 Test Sponsor: FTC - Fabbrica Trentina Conduttori

More information

THE MYSORE UNIT OF RPG CABLES MANUFACTURES A RANGE OF INSTRUMENTATION CABLES

THE MYSORE UNIT OF RPG CABLES MANUFACTURES A RANGE OF INSTRUMENTATION CABLES THE MYSORE UNIT OF RPG CABLES MANUFACTURES A RANGE OF INSTRUMENTATION CABLES The Mysore Unit of RPG Cables is the largest and most diversified cables manufacturing facility in the South of India. The unit

More information

The Quality Connection. BETAflam Fire Resistant Safety Cables

The Quality Connection. BETAflam Fire Resistant Safety Cables The Quality Connection BETAflam Fire Resistant Safety Cables BETAflam Contact Your personal customer number To offer you a more efficient service, we kindly ask you to mention your personal customer number

More information

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES INDEX Corflex MC-HL Instrumentation - Pairs and Triads (0V*)... 1 - CORFLEX Cables

More information

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION Fire alarm cables for highest safety requirements TRADITION INNOVATION PASSION Datwyler Datwyler Cabling Solutions is an internationally operating company with its headquarters in Switzerland and affiliates

More information

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards 1. SCOPE This Specification details requirements for General Wiring cables up to and including 450/750V for use on lighting and general power wiring installations complying with BS 7671 but not forming

More information

Certificate No. DNV-2009-OSL-ALARM This Certificate consists of 5 pages. This is to certify that the product PIR / DUAL TECHNOLOGY DETECTORS

Certificate No. DNV-2009-OSL-ALARM This Certificate consists of 5 pages. This is to certify that the product PIR / DUAL TECHNOLOGY DETECTORS DET NORSKE VERITAS CERTIFICATE OF CONFORMITY Certificate No. DNV-2009-OSL-ALARM-55363 This Certificate consists of 5 pages This is to certify that the product PIR / DUAL TECHNOLOGY DETECTORS with name

More information

GLASS FIBRE REINFORCEMENTS

GLASS FIBRE REINFORCEMENTS STANDARD FOR CERTIFICATION No. 2.9 GLASS FIBRE REINFORCEMENTS OCTOBER 2009 Veritasveien 1, NO-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD (DNV) is an autonomous and independent

More information

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com IEC 60331-11-21 Method of test defined in

More information

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES 37-754 FLAME RETARDANT EP/CPE TYPE TC OR TC-ER POWER CABLE Two Five Conductor + Ground (Two, Three & Four Conductor) 600 V Rated 90 C Conductor*

More information

OIL & GAS INDUSTRY OTHER INDUSTRIES

OIL & GAS INDUSTRY OTHER INDUSTRIES For ATEX Areas OIL & GAS INDUSTRY OTHER INDUSTRIES OIL & GAS INDUSTRY POTENTIALLY HAZARDOUS Class I GASES VAPORS LIQUIDS Petrosumsave Zone 0 An area in which an explosive mixture is continuously present,

More information

fire resistant cables

fire resistant cables Building Technology fire resistant cables Special electrical and optical cables www.tecnikabel.com Special electrical and optical cables 2 INTRODUCTION Structured cabling solutions. Tecnikabel can provide

More information

Low Smoke Zero Halogen

Low Smoke Zero Halogen Low Smoke Zero Halogen Cable for Marine Applications 621 Time Saver Avenue Harahan, LA 70123 Call Toll Free: (888) 326-5174 Email: marine@summit.com Marine Division summit.com/marine Power and Control

More information

Bergen Cabling the best from two worlds in one single solution

Bergen Cabling the best from two worlds in one single solution IT infrastructure vendor & systems integrator SOHOME AS Grimstadvegen 93 NO-5252 Søreldgrend Norway Tel.: +47 55 31 27 00 e-mail: salg@sohome.no website: www.sohome.no Bergen Cabling the best from two

More information

Compact Module. Category 6A FTP Cabling System 1.1

Compact Module. Category 6A FTP Cabling System 1.1 Updated 24/09/12 Compact Module Cat 6A performance Suitable for 10-Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro Modules and blanks Individually QA tested Easy

More information

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red OFC-UT-CST Fire resistant Armoured Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU

More information

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Ad-hoc IEC 60331-2 x Ad-hoc investigation

More information

Multi-Core Fire Resistant Cable

Multi-Core Fire Resistant Cable Fire Resistant Cables / Multi-Core Fire Resistant Cable Approved to UL 444, Zeta ZFP series cables have received UL approval for standard applications. Standards Alarm Cable Z UL 444 Approval CMH Rated

More information

LSOH Wiring Cables. LSOH Conduit Wire (HO7Z-R) Low Voltage (450/750 V) Cable Approvals. Key Applications. Conductor. Insulation. Core Identification

LSOH Wiring Cables. LSOH Conduit Wire (HO7Z-R) Low Voltage (450/750 V) Cable Approvals. Key Applications. Conductor. Insulation. Core Identification LSOH Wiring Cables Low Voltage (450/750 V) LSOH Conduit Wire (HO7Z-R) Cable Approvals Cable approved to BS7211 Key Applications > Manufactured to BS EN 50525-3-41 90 C cross linked (previously BS 7211)

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60092-376 Second edition 2003-05 Electrical installations in ships Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) Installations électriques à bord

More information

Caledonian fire Resistant signal & Data cables

Caledonian fire Resistant signal & Data cables fire Resistant signal & Data cables www.addison-tech.com fire Resistant Rs485 Databus cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Mica Glass Tape+PE/PE+Silicone Rubber Insulation

More information

Corporate Presentation. 14 June 2009

Corporate Presentation. 14 June 2009 Corporate Presentation 14 June 2009 History 1979 - Ducab was formed as a joint venture between Government of Dubai and BICC Group of the UK History Quality Systems & Certification Awards 2001 Ducab jointly

More information

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Ad-hoc IEC 60331-2 x Ad-hoc investigation

More information