Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

Size: px
Start display at page:

Download "Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document"

Transcription

1 of 79 1/27/2016 2:09 PM Public Input No. 1-NFPA [ Global Input ] Throughout standard remove references to the following and replace with the following: (1) ANSI/API and replace with API. (2) ANSI/UL and replace with UL. (3) API # and replace with API SPEC, STD, or RP #. Related Public Inputs for This Document Related Input Relationship

2 of 79 1/27/2016 2:09 PM Public Input No. 5-NFPA [ Section No ] Liquefied Petroleum Gas Code Additional Proposed Changes File Name Description Approved

3 of 79 1/27/2016 2:09 PM Public Input No. 2-NFPA [ Section No. 2.3 ] SPEC Specifications for Fire Tests for Valves, 3rd edition, 1999, Reaffirmed 2011 STD Fire Test for Quarter-Turn Valves and Valves Equipped with Nonmetallic Seats, 6th Edition, 2010 STD Design and Construction of Large, Welded, Low-Pressure Storage Tanks, 2013, Amendment 1, Minimum Design Loads for Buildings and Other Structures, 10th edition, 2010, Errata, 2011, and Revised Commentary 2013 ASME International Two Boiler and Pressure Vessel Code, 2015 Process Piping, 2014 /A47M Standard Specification for Ferritic Malleable Iron Castings, 1999, Reapproved 2014 /A395M Specification for Ferritic Ductile Iron Pressure-Retaining Castings for Use at Elevated Temperatures, 1999, Reapproved 2014 Specifications for Ductile Iron Castings, 1984, Reapproved Standard on Safety Relief Valves for Anhydrous Ammonia and LP-Gas Revised Publishing Merriam-Webster s Collegiate Dictionary Related Public Inputs for This Document Related Input Relationship

4 of 79 1/27/2016 2:09 PM Statement:

5 of 79 1/27/2016 2:09 PM Public Input No. 10-NFPA [ New Section after ] ACI Publications. American Concrete Institute, P.O. Box 9094, Farmington Hills, MI Code requirements for Design and Construction of Concrete Structures for the Containment of Refrigerated Gases

6 of 79 1/27/2016 2:09 PM Public Input No. 11-NFPA [ Section No ] Specifications for Fire Tests for Valves, Fire Test for Soft-Seated Quarter-Turn Valves, Sixth Edition, September 2010 Design and Construction of Large, Welded, Low-Pressure Storage Tanks, Twelth Edition October 2013 with Addendum 1 November API 625, Tank Systems for Refrigerated Liquefied Gas Storage, First Edition, 2010, with addendum 1, July 1, 2013 Related Public Inputs for This Document Related Input Relationship

7 of 79 1/27/2016 2:09 PM Public Input No. 12-NFPA [ Section No ] Minimum Design Loads for Buildings and Other Structures,

8 of 79 1/27/2016 2:09 PM Public Input No. 13-NFPA [ Section No ] Boiler and Pressure Vessel Code, Process Piping,

9 of 79 1/27/2016 2:09 PM Public Input No. 14-NFPA [ Section No ] Standard Specification for Ferritic Malleable Iron Castings, Specification for Ferritic Ductile Iron Pressure-Retaining Castings for Use at Elevated Temperatures, Specifications for Ductile Iron Castings,

10 0 of 79 1/27/2016 2:09 PM Public Input No. 15-NFPA [ Section No ] Standard on Safety Relief Valves for Anhydrous Ammonia and LP-Gas

11 1 of 79 1/27/2016 2:09 PM Public Input No. 9-NFPA [ Section No ] Standard on Safety Relief Valves for Anhydrous Ammonia and LP-Gas

12 2 of 79 1/27/2016 2:09 PM Public Input No. 19-NFPA [ New Section after ] 3.XXX Component Related Public Inputs for This Document Related Input Relationship

13 3 of 79 1/27/2016 2:09 PM Public Input No. 20-NFPA [ New Section after ] 3.3.XXX Facility Related Public Inputs for This Document Related Input Relationship

14 4 of 79 1/27/2016 2:09 PM Public Input No. 18-NFPA [ New Section after ] 3.3.XX Plant

15 5 of 79 1/27/2016 2:09 PM Public Input No. 16-NFPA [ New Section after ] 3.3 Process Pressure Vessel

16 6 of 79 1/27/2016 2:09 PM Public Input No. 17-NFPA [ New Section after ] Refrigerated Storage Tank System Refrigerated Storage Tank System. Low pressure (less than 15 psi) equipment designed for the purpose of storing refrigerated LPG consisting of one or more containers, together with various accessories, appurtenances, and insulation Related Public Inputs for This Document Related Input Relationship

17 7 of 79 1/27/2016 2:09 PM Public Input No. 59-NFPA [ Section No ] *

18 8 of 79 1/27/2016 2:09 PM Public Input No. 57-NFPA [ Section No ]

19 9 of 79 1/27/2016 2:09 PM

20 0 of 79 1/27/2016 2:09 PM NFPA 70 National Electrical Code Equipment Shall be Approved for National Electrical Code, Part Location Extent of Classified Area a Class I a, Group D b A ) (see Figure

21 1 of 79 1/27/2016 2:09 PM Figure A ) (see (see Figure A ) NFPA 70 National Electrical Code Related Public Inputs for This Document

22 2 of 79 1/27/2016 2:09 PM Related Input Relationship

23 3 of 79 1/27/2016 2:09 PM Public Input No. 21-NFPA [ Section No [Excluding any Sub-Sections] ] Related Public Inputs for This Document Related Input Relationship

24 4 of 79 1/27/2016 2:09 PM Public Input No. 22-NFPA [ Section No ] Related Public Inputs for This Document Related Input Relationship

25 5 of 79 1/27/2016 2:09 PM Public Input No. 6-NFPA [ New Section after ] 4.9 Corrosion Protection Additional Proposed Changes File Name Description Approved

26 6 of 79 1/27/2016 2:09 PM Statement:

27 7 of 79 1/27/2016 2:09 PM Public Input No. 23-NFPA [ Section No ]

28 8 of 79 1/27/2016 2:09 PM Public Input No. 61-NFPA [ Section No ] Statement:

29 9 of 79 1/27/2016 2:09 PM Public Input No. 60-NFPA [ Section No ] 5.8.1

30 0 of 79 1/27/2016 2:09 PM Public Input No. 58-NFPA [ Chapter 6 ] Boiler and Pressure Vessel Code Boiler and Pressure Vessel Code Design and Construction of Large, Welded, Low-Pressure Storage Tanks, Design and Construction of Large, Welded, Low-Pressure Storage Tanks, Construction of Large, Welded, Low-Pressure Storage Tanks, Design and

31 1 of 79 1/27/2016 2:09 PM Tanks Design and Construction of Large, Welded, Low-Pressure Storage Low-Pressure Storage Tanks, Design and Construction of Large, Welded, and Other Structures Minimum Design Loads for Buildings Minimum Design Loads for Buildings and Other Structures

32 2 of 79 1/27/2016 2:09 PM Process Piping

33 3 of 79 1/27/2016 2:09 PM

34 4 of 79 1/27/2016 2:09 PM Design and Construction of Large, Welded, Low-Pressure Storage Tanks

35 5 of 79 1/27/2016 2:09 PM [Please see SUGGESTED Reorganization and rewrite of NFPA 59 Chapter 6 from American Gas Association, Supplemental Gas Committee, Attached]

36 6 of 79 1/27/2016 2:09 PM Water Capacity per Container Aboveground Containers gal m 3 ft m 6. Water Capacity per Container Aboveground Containers gal m 3 ft m Additional Proposed Changes File Name Description Approved

37 7 of 79 1/27/2016 2:09 PM Related Public Inputs for This Document Related Input Relationship Statement:

38 8 of 79 1/27/2016 2:09 PM Public Input No. 24-NFPA [ Section No ] Related Public Inputs for This Document Related Input Relationship

39 9 of 79 1/27/2016 2:09 PM Public Input No. 25-NFPA [ Chapter 7 [Title Only] ] Piping, Valves, Process Pressure Vessels and Equipment Related Public Inputs for This Document Related Input Relationship

40 0 of 79 1/27/2016 2:09 PM Public Input No. 28-NFPA [ New Section after ] Buried flammable liquid or gas piping shall be installed with a minimum of 30 inches of cover in normal soil and a minimum of 18 inches in consolidated rock.

41 1 of 79 1/27/2016 2:09 PM Public Input No. 29-NFPA [ New Section after ] Buried flammable liquid or gas piping shall be installed with a minimum of 12 inches clearance between the pipe and any other structure not associated with the pipe to allow for proper maintenance

42 2 of 79 1/27/2016 2:09 PM Public Input No. 30-NFPA [ Section No ] Statement:

43 3 of 79 1/27/2016 2:09 PM Public Input No. 27-NFPA [ Section No ] Valves Fire Test for Soft-Seated Quarter-Turn Valves Specifications for Fire Tests for Statement:

44 4 of 79 1/27/2016 2:09 PM Public Input No. 31-NFPA [ Section No ] Statement:

45 5 of 79 1/27/2016 2:09 PM Public Input No. 32-NFPA [ Section No ] Statement:

46 6 of 79 1/27/2016 2:09 PM Public Input No. 33-NFPA [ Section No ] Statement:

47 7 of 79 1/27/2016 2:09 PM Public Input No. 34-NFPA [ Section No ] Statement:

48 8 of 79 1/27/2016 2:09 PM Public Input No. 35-NFPA [ Section No ] Related Public Inputs for This Document Related Input Relationship

49 9 of 79 1/27/2016 2:09 PM Public Input No. 26-NFPA [ New Section after ] 7.9 * Process pressure vessels shall be designed and fabricated in accordance with the ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, or Division 2, or with the CSA B51, Boiler Pressure Vessel and Piping Code, and shall be code-stamped Related Public Inputs for This Document Related Input Relationship

50 0 of 79 1/27/2016 2:09 PM Public Input No. 36-NFPA [ Section No ] Exception: Such anchorage shall not be required for the tank car side. Related Public Inputs for This Document Related Input Relationship

51 1 of 79 1/27/2016 2:09 PM Public Input No. 37-NFPA [ Section No ] Statement:

52 2 of 79 1/27/2016 2:09 PM Public Input No. 38-NFPA [ Section No [Excluding any Sub-Sections] ] Related Public Inputs for This Document Related Input Relationship

53 3 of 79 1/27/2016 2:09 PM Public Input No. 39-NFPA [ Section No ] Fuel Gas Code 101 Life Safety Code National Statement:

54 4 of 79 1/27/2016 2:09 PM Public Input No. 62-NFPA [ Section No ] * Exposure Minimum Distance Required Between Vaporizer and Exposure ft m (see Section 9.5) Additional Proposed Changes File Name Description Approved

55 5 of 79 1/27/2016 2:09 PM Public Input No. 63-NFPA [ Section No ]

56 6 of 79 1/27/2016 2:09 PM Public Input No. 40-NFPA [ Section No ] Statement:

57 7 of 79 1/27/2016 2:09 PM Public Input No. 41-NFPA [ Section No ]

58 8 of 79 1/27/2016 2:09 PM Statement:

59 9 of 79 1/27/2016 2:09 PM Public Input No. 42-NFPA [ Section No ] Related Public Inputs for This Document Related Input Relationship

60 0 of 79 1/27/2016 2:09 PM Public Input No. 43-NFPA [ New Section after 12.7 ]

61 1 of 79 1/27/2016 2:09 PM Public Input No. 48-NFPA [ Section No [Excluding any Sub-Sections] ] Related Public Inputs for This Document Related Input Relationship

62 2 of 79 1/27/2016 2:09 PM Public Input No. 44-NFPA [ New Section after ]

63 3 of 79 1/27/2016 2:09 PM Public Input No. 45-NFPA [ Section No ] 13.2 Fire Alarm and Signaling Code NFPA 72 National Related Public Inputs for This Document Related Input Relationship

64 4 of 79 1/27/2016 2:09 PM Statement:

65 5 of 79 1/27/2016 2:09 PM Public Input No. 46-NFPA [ New Section after ] *Where utilized, leak detection should be used to compliment fire and gas detection and is not intended to replace fire and gas detection Related Public Inputs for This Document Related Input Relationship

66 6 of 79 1/27/2016 2:09 PM Public Input No. 49-NFPA [ Section No ] NFPA 25, Systems Standard for the Installation of Sprinkler Systems Standard for the Installation of Standpipe and Hose Systems Standard for Water Spray Fixed Systems for Fire Protection Standard for the Installation of Stationary Pumps for Fire Protection Standard for Water Tanks for Private Fire Protection Standard for the Installation of Private Fire Service Mains and Their Appurtenances Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Standard on Fire Hose Standard for the Care, Use, Inspection, Service Testing, and Replacement of Fire Hose, Coupling, Nozzles, and Fire Hose Appliances. Standard for Fire Hose Connections Related Public Inputs for This Document Related Input Relationship Statement:

67 7 of 79 1/27/2016 2:09 PM

68 8 of 79 1/27/2016 2:09 PM Public Input No. 8-NFPA [ Section No ] Affilliation: Statement:

69 9 of 79 1/27/2016 2:09 PM Public Input No. 50-NFPA [ Section No ] Standard for Portable Fire Extinguishers Standard for Low-, Medium-, and High-Expansion Foam Standard on Carbon Dioxide Extinguishing Systems Standard on Halon 1301 Fire Extinguishing Systems Standard for the Installation of Foam-Water Sprinkler and Foam-Water Spray Systems Standard for Dry Chemical Extinguishing Systems Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems Standard on Clean Agent Fire Extinguishing Systems Related Public Inputs for This Document Related Input Relationship Statement:

70 0 of 79 1/27/2016 2:09 PM Public Input No. 51-NFPA [ Section No ] Statement:

71 1 of 79 1/27/2016 2:09 PM Public Input No. 52-NFPA [ Section No ] Related Public Inputs for This Document Related Input Relationship

72 2 of 79 1/27/2016 2:09 PM Public Input No. 53-NFPA [ New Section after A ] A When classifying the extent of an entire facility or a specific portion of the facility, consideration should be given to increasing the extent of the hazardous area location above those stated in the NEC and NFPA 59 Table based on higher flow rates and pressures utilized within larger facilities. Additional guidance for extending electrical area classifications can be found in NFPA 497 Electrical Installations in Chemical Atmospheres Involving Flammable Liquids, Gases, or Vapors. Statement:

73 3 of 79 1/27/2016 2:09 PM Public Input No. 54-NFPA [ New Section after A ]

74 4 of 79 1/27/2016 2:09 PM Public Input No. 55-NFPA [ Sections A.10.1, A ] Sections A.10.1, A Guide for Pressure-Relieving and Depressuring Systems and Containers for Entry, Cleaning, or Repair Standard for the Safeguarding of Tanks Purging Principles and Practice Related Public Inputs for This Document Related Input Relationship

75 5 of 79 1/27/2016 2:09 PM Statement:

76 6 of 79 1/27/2016 2:09 PM Public Input No. 47-NFPA [ New Section after A ] A Leak detection used to compliment gas detection systems, leak detection may include but not limited to acoustic (ultrasonic)? which, detects small leak rates (mass/time), vapor cloud video surveillance cameras? which, detects gas cloud size, Low Temperature Detectors, including Resistant Temperature Detectors (RTD), and Linear Leak Detection (such as fiber optic leak detection technology). Related Public Inputs for This Document Related Input Relationship

77 7 of 79 1/27/2016 2:09 PM Public Input No. 56-NFPA [ New Section after A ] Statement:

78 8 of 79 1/27/2016 2:09 PM Public Input No. 3-NFPA [ Section No. F.1.2 ] Interchangeability of Other Fuel Gases with Natural Gas, Interchangeability What it Means, Introduction to LPG Safety for Propane Air Plant Operators, Purging Principles and Practice, 2014 STD Guide for Pressure-Relieving and Depressuring Systems, 6th edition, Protection Against Ignitions Arising out of Static, Lightning, and Stray Currents, ASME Internationl Two Boiler and Pressure Vessel Code, 2015 NACE Systems 2013, Park Ten Place Control of External Corrosion of Underground or Submerged Metallic Piping NACE Control of Corrosion Under Thermal Insulation and Fireproofing Materials A Systems Approach NACE Protection Corrosion Control of Underground Storage Tank Systems by Cathodic Publishing Related Public Inputs for This Document Related Input Relationship

79 9 of 79 1/27/2016 2:09 PM

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document of 78 9/22/2015 11:20 AM Public Input No. 1-NFPA 59-2015 [ Global Input ] Throughout standard remove references to the following and replace with the following: (1) ANSI/API and replace with API. (2) ANSI/UL

More information

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM 1 of 11 1/18/2016 5:43 PM First Revision No. 2-NFPA 51-2015 [ Global Input ] Throughout standard remove references to the following and replace with the following: (1) CGA C-7 Guide to Precautionary Labelling

More information

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ] 8 of 93 11/6/2015 7:41 AM Public Input No. 52-NFPA 30-2015 [ Section No. 21.2 [Excluding any Sub-Sections] ] For the purpose of this chapter, the term in this section shall have the definitions given.

More information

First Revision No. 1-NFPA 30A-2015 [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

First Revision No. 1-NFPA 30A-2015 [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement of 35 1/21/2016 7:56 AM First Revision No. 1-NFPA 30A-2015 [ Section No. 1.1.3 ] 1.1.3* This code shall not apply to those motor fuel dispensing facilities where only liquefied petroleum gas (LP-Gas),

More information

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement 1 of 7 3/4/2016 12:02 PM Second Revision No. 5-NFPA 56-2016 [ Section No. 1.1.2 ] 1.1.2 Nonapplication of Standard. This standard shall not apply to the following items: (1)* Piping systems covered by

More information

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification Public Input No. 1-NFPA 36-2013 [ Global Input ] Revise the document to eliminate the use of "Exception" text. The use of "Exception" text is inconsistent with the Manual of Style. Exception text should

More information

Preliminary Agenda Technical Committee on Liquefied Petroleum Gas

Preliminary Agenda Technical Committee on Liquefied Petroleum Gas Preliminary Agenda Technical Committee on Liquefied Petroleum Gas Tuesday, March 10; All Day Wednesday, March 11; All Day DRURY PLAZA HOTEL San Antonio Riverwalk 0. Administrative. A. Meeting Schedule.

More information

Standard Compared 2012 Changes of the International Building Code and National Fire Protection Association- 101

Standard Compared 2012 Changes of the International Building Code and National Fire Protection Association- 101 Standard Compared 2012 Changes of the International Building Code and National Fire Protection Association- 101 For the Florida Building Commission And the Fire Code Advisory Council Introduction The scope

More information

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016)

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Solvent Extraction Plants

More information

Adobe Connect - Invitation to NFPA 385 Second Draft Web Conference

Adobe Connect - Invitation to NFPA 385 Second Draft Web Conference Matthews, Diane Subject: Location: Start: End: Show Time As: Recurrence: Meeting Status: Organizer: Required Attendees: Adobe Connect - Invitation to NFPA 385 Second Draft Web Conference http://nfpa.adobeconnect.com/rpbmeet/

More information

Department of Public Safety

Department of Public Safety Terry E. Branstad Governor Kim Reynolds Lt. Governor Department of Public Safety Roxann M. Ryan Commissioner Liquid Propane Informational guide to submitting plans Plans are to be submitted to: State Fire

More information

Above Ground Fuel Tank Requirements

Above Ground Fuel Tank Requirements FIRE DEPARTMENT in cooperation with Above Ground Fuel Tank Requirements The purpose of this document is to provide information about general Fire Code requirements for above ground storage within the unincorporated

More information

Temporary LPG Heat for Construction Sites Information Packet

Temporary LPG Heat for Construction Sites Information Packet Temporary LPG Heat for Construction Sites Information Packet Colorado Springs Fire Department Division of the Fire Marshal February 2014 W:\Packets\Haz Mat\IFC2009_Temp_LPG_Heat_For_Construction.doc TEMPORARY

More information

Page 1 of 13 Second Revision No. 1-NFPA 326-2014 [ Section No. 2.3.1 ] 2.3.1 ACGIH Publications. American Conference of Governmental Industrial Hygienists, 1330 Kemper Meadow Drive, Cincinnati, OH 45240-1634.

More information

This standard applies to new installations and to those portions of existing equipment and installations that are modified

This standard applies to new installations and to those portions of existing equipment and installations that are modified NFPA STANDARDS DEVELOPMENT SITE SECOND DRAFT REPORT Closing Date: July 19, 2013 NOTE: All Public Comment must be received by 5:00 pm EST/EDST on the published Closing Date. NFPA 37, Standard for the Installation

More information

NFPA 30 FLC-FUN Public Inputs Page 1 of 26. Public Input No. 5-NFPA [ Section No. 2.3 ] 11/6/2015 7:41 AM

NFPA 30 FLC-FUN Public Inputs Page 1 of 26. Public Input No. 5-NFPA [ Section No. 2.3 ] 11/6/2015 7:41 AM of 93 11/6/2015 7:41 AM Public Input No. 5-NFPA 30-2015 [ Section No. 2.3 ] 2.3 Other Publications. 2.3.1 API Publications. American Petroleum Institute, 1220 L Street, NW, Washington, DC 20005-4070. API

More information

Flammable Liquid: A liquid whose flashpoint is greaterless than 100 F when tested by closed-cup test methods.

Flammable Liquid: A liquid whose flashpoint is greaterless than 100 F when tested by closed-cup test methods. ANSI/IIAR 2-2014 Addendum A Standard for Safe Design of Closed-Circuit Ammonia Refrigeration Systems Public Review Draft #3 Reviewers of Addendum A are welcome to comment on the changes in the standard,

More information

CHAPTER 45 REFERENCED STANDARDS

CHAPTER 45 REFERENCED STANDARDS CHAPTER 45 REFERENCED STANDARDS This chapter lists the standards that are d in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard

More information

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content Based on the 2018 International Fire Code, (IFC ) The International Fire Code (IFC ), establishes minimum regulations for fire safety. This handout will identify important changes in the IFC from 2015

More information

First Revision No. 20-NFPA [ Section No ]

First Revision No. 20-NFPA [ Section No ] of 25 7/15/2015 8:30 AM First Revision No. 20-NFPA 56-2015 [ Section No. 1.1.2 ] 1.1.2 Nonapplication of Standard. This standard shall not apply to the following items: (1)* Piping systems covered by NFPA

More information

ARTICLE 25. FUEL GAS CODE

ARTICLE 25. FUEL GAS CODE ARTICLE 25. Rule 1. Indiana Fuel Gas Code, 2003 Edition (Repealed) (Repealed by Fire Prevention and Building Safety Commission; filed Mar 18, 2008, 2:32 p.m.: 20080423-IR-675070479FRA, eff 90 days after

More information

CHAPTER 45 REFERENCED STANDARDS

CHAPTER 45 REFERENCED STANDARDS CHAPTER 45 REFERENCED STANDARDS Point of Information City of Seattle Ordinance 121524 adopts the 2003 Seattle Fire Code and adds the following three National Fire Protection s, as amended by that same

More information

12/21/2015 National Fire Protection Association Report

12/21/2015 National Fire Protection Association Report http://submittals.nfpa.org/terraviewweb/viewerpage.jsp?id=232 2012.ditamap&toc=false&draft=true 1/9 Public Comment No. 1 NFPA 232 2015 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents

More information

Public Safety [661] Chapter 226, Liquefied Petroleum Gas, Amended for Application within the State of Iowa

Public Safety [661] Chapter 226, Liquefied Petroleum Gas, Amended for Application within the State of Iowa Public Safety [661] Chapter 226, Liquefied Petroleum Gas, Pursuant to the authority of Iowa Code section 101.1, the State Fire Marshal hereby adopts new Chapter 226, Liquefied Petroleum Gas, Iowa Administrative

More information

First Revision No. 82-NFPA [ Detail ] Submitter Information Verification Submitter Full Name: Organization:

First Revision No. 82-NFPA [ Detail ] Submitter Information Verification Submitter Full Name: Organization: of 176 1/25/2016 3:32 PM First Revision No. 82-NFPA 54-2015 [ Detail ] Title of 7.1: Installation of Underground Piping. Underground Title of 7.2: Installation of Aboveground Piping. Submittal Date: Thu

More information

MEMORANDUM. NFPA 51 First Draft Technical Committee FINAL Ballot Results (A2017 Cycle)

MEMORANDUM. NFPA 51 First Draft Technical Committee FINAL Ballot Results (A2017 Cycle) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM TO: FROM: Technical Committee on Industrial and Medical Gases

More information

Change all instances of "flame resistant (hypobaric)" to "Limited-Combustible (material)" in all instances in the document.

Change all instances of flame resistant (hypobaric) to Limited-Combustible (material) in all instances in the document. 1 of 9 10/21/2015 1:22 PM First Revision No. 3-NFPA 99B-2015 [ Global Input ] Change all instances of "flame resistant (hypobaric)" to "Limited-Combustible (material)" in all instances in the document.

More information

Public Input No. 1-NFPA 99B-2015 [ Section No. 2.3 ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

Public Input No. 1-NFPA 99B-2015 [ Section No. 2.3 ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document 1 of 19 10/21/2015 1:20 PM Public Input No. 1-NFPA 99B-2015 [ Section No. 2.3 ] 2.3 Other Publications. 2.3.1 ASME Publications. American Society of Mechanical Engineers, Three ASME International, Two

More information

Throughout standard remove references to the following and replace with the following:

Throughout standard remove references to the following and replace with the following: of 105 1/21/2016 7:49 AM Public Input No. 2-NFPA 30A-2015 [ Global Input ] Throughout standard remove references to the following and replace with the following: (1) ANSI/UL and replace with UL. (2) ANSI

More information

PROPOSED CHANGE TO THE 2007 FIRE CODE (OFC)

PROPOSED CHANGE TO THE 2007 FIRE CODE (OFC) TO THE 2007 FIRE CODE (OFC) OFC Record Division: A Reference Number: 1.4.1.2. (dwelling unit) Corresponding NFC Change Division: A Reference Number: 1.4.1.2.(1) OFC Revise definition for Dwelling unit

More information

Public Input No. 3-NFPA [ Chapter 2 ]

Public Input No. 3-NFPA [ Chapter 2 ] Public Input No. 3-NFPA 655-2014 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard and shall be considered

More information

First Revision No. 22-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

First Revision No. 22-NFPA [ Global Input ] Submitter Information Verification. Committee Statement of 28 2/2/2016 9:39 AM First Revision No. 22-NFPA 37-2015 [ Global Input ] Add the following definitions to chapter 3: 3.3.x Service Regulator. A pressure regulator installed by the serving gas supplier

More information

First Revision No. 1-NFPA [ Chapter 2 ]

First Revision No. 1-NFPA [ Chapter 2 ] First Revision No. 1-NFPA 499-2014 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this recommended practice

More information

North Liberty Fire Department Permit Application Temporary Storage & Use of LPG

North Liberty Fire Department Permit Application Temporary Storage & Use of LPG Application Fee: $50.00 Application Date: Permit Information Have you previously applied for this type of permit? Date of previous application: Owner/Applicant Information Applicant s Last Name: Applicant

More information

Government Gazette Staatskoerant

Government Gazette Staatskoerant Government Gazette Staatskoerant REPUBLIC OF SOUTH AFRICA REPUBLIEK VAN SUID AFRIKA Regulation Gazette No. 10177 10701 Regulasiekoerant Regulation Gazette Vol. 621 24 March Maart 2017 No. 40713 PART 1

More information

Nfpa 85 Download or Read Online ebook nfpa 85 in PDF Format From The Best User Guide Database

Nfpa 85 Download or Read Online ebook nfpa 85 in PDF Format From The Best User Guide Database Nfpa 85 Free PDF ebook Download: Nfpa 85 Download or Read Online ebook nfpa 85 in PDF Format From The Best User Guide Database 400-499. 500-599. 600-699. 700-799. 800-899. 900-999. 900 Building Energy

More information

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document National Fire Protection Association Report of 113 http://submittals.nfpa.org/terraviewweb/contentfetcher?commentpara... 2/9/2016 10:50 AM Public Input No. 1-NFPA 87-2015 [ Global Input ] Throughout standard

More information

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input of 280 2/6/2015 12:06 PM Public Input No. 1-NFPA 58-2013 [ Global Input ] NOTE: This public input originates from Tentative Interim Amendment 58-14-1 (TIA 1079) issued by the Standards Council on August

More information

OUTLINE FOR FIRE PREVENTION ACTIVITY

OUTLINE FOR FIRE PREVENTION ACTIVITY OUTLINE FOR FIRE PREVENTION ACTIVITY Background Buildings under construction present unique fire exposures that require special attention. Fires can result in major losses and long delays in the completion

More information

Liquefied Petroleum Gas Facility Written Fire Safety Analysis

Liquefied Petroleum Gas Facility Written Fire Safety Analysis Liquefied Petroleum Gas Facility Written Fire Safety Analysis For INDEX Page Introduction 2 Conducting the WFSA 2 WFSA CHECKLIST Section I Facility Information 3 Section II Facility Storage Container Information

More information

MODULE 2. Water-Based Suppression System Basics

MODULE 2. Water-Based Suppression System Basics MODULE 2 Water-Based Suppression System Basics Based on the Ohio Building Code (OBC) National Fire Protection Association (NFPA) & Ohio Fire Code (OFC) 1 WATER-BASED SUPPRESSION SYSTEM BASICS-PART ONE

More information

Liquefied Petroleum Gas Facility Written Fire Safety Analysis

Liquefied Petroleum Gas Facility Written Fire Safety Analysis Liquefied Petroleum Gas Facility Written Fire Safety Analysis For Completed by Facility manager Received by Fire Department/Emergency Response representative Date Date INDEX Page Introduction 2 Conducting

More information

The following preprint is based on the First Revision Draft of the 2018 edition of NFPA 54/Z223.1.

The following preprint is based on the First Revision Draft of the 2018 edition of NFPA 54/Z223.1. Copyright 2016 by American Gas Association and the National Fire Protection Association, All Rights Reserved BSR Z223.1 20xx NFPA 54 20xx National Fuel Gas Code 2018 Edition NOTE: This preprint of the

More information

NFPA 54 UPDATE. Paul Cabot American Gas Association

NFPA 54 UPDATE. Paul Cabot American Gas Association NFPA 54 UPDATE Paul Cabot American Gas Association PRESENTATION TOPICS Summary Listing Schedule Revisions Definitions/General Piping Appliances and Appliance Installation Venting 2015 Edition Revision

More information

Remove the "Exception" text to be consistent with direction provided in the MOS.

Remove the Exception text to be consistent with direction provided in the MOS. of 37 1/11/2017 7:38 AM Public Input No. 9-NFPA 88A-2015 [ Global Input ] Remove the "Exception" text to be consistent with direction provided in the MOS. The current language in 88A has numerous section

More information

Second Revision No. 1 NFPA [ Chapter 2 ]

Second Revision No. 1 NFPA [ Chapter 2 ] Second Revision No. 1 NFPA 232 2015 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard and shall be

More information

The distances in shall be reduced to 130 ft (39.7 m) when manual dry standpipes are installed in open parking garages.

The distances in shall be reduced to 130 ft (39.7 m) when manual dry standpipes are installed in open parking garages. of 123 6/10/2014 9:07 AM First Revision No. 117-NFPA 14-2014 [ Global Input ] 7.3.2.7.5 The distances in 7.3.2.2 shall be reduced to 130 ft (39.7 m) when manual dry standpipes are installed in open parking

More information

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: NEC Code-Making Panel 14 From: Kimberly Shea, Project Administrator

More information

2009 NFPA Text 2009 International Building Code Text Recommendation. NFPA IBC 2009 IBC is most recent

2009 NFPA Text 2009 International Building Code Text Recommendation. NFPA IBC 2009 IBC is most recent 2009 Changes of the Referenced Standards of the National Fire Protection Association- 101 Compared to the International Building Code- 2009 Referenced Standards For the Florida Building Commission And

More information

First Revision No. 36-NFPA [ Section No. 1.1 [Excluding any Sub-Sections] ]

First Revision No. 36-NFPA [ Section No. 1.1 [Excluding any Sub-Sections] ] of 71 6/11/2014 8:20 AM First Revision No. 36-NFPA 76-2014 [ Section No. 1.1 [Excluding any Sub-Sections] ] This standard provides requirements for fire protection of telecommunications facilities where

More information

California Fire Code (CFC) Part III contains requirements. Building and Equipment Design Features PART. Chapters 5 through 19

California Fire Code (CFC) Part III contains requirements. Building and Equipment Design Features PART. Chapters 5 through 19 PART 3 Building and Equipment Design Features Chapters 5 through 19 Chapter 5 Fire Service Features No changes addressed Chapter 6 Building Services and Systems Chapter 7 Fire-Resistance-Rated Construction

More information

GASEOUS HYDROGEN SYSTEMS

GASEOUS HYDROGEN SYSTEMS CHAPTER 7 GASEOUS HYDROGEN SYSTEMS SECTION 701 GENERAL 701.1 Scope. The installation of gaseous hydrogen systems shall comply with this chapter and Chapters 30 and 35 of the Fire Compressed gases shall

More information

CENTRAL STATE HOSPITAL PLAN SAFE USE HANDLING AND STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

CENTRAL STATE HOSPITAL PLAN SAFE USE HANDLING AND STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS Page 1 of 6 CENTRAL STATE HOSPITAL PLAN SUBJECT: SAFE USE HANDLING AND STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS ANNUAL REVIEW MONTH: RESPONSIBLE FOR REVIEW: APRIL CSH SAFETY DIRECTOR LAST REVISION

More information

August Process Industry Practices Electrical. PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification

August Process Industry Practices Electrical. PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification Electrical Engineering Guide for Determining Electrical Area Classification PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice

More information

SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Water heaters B. Packaged water heating systems C. Water storage tanks D. Water softeners E. Pumps F. Circulators 1.2 REFERENCES SECTION 22 30 00 PLUMBING EQUIPMENT

More information

Fire Prevention Plan Program

Fire Prevention Plan Program Fire Prevention Plan Program Effective Date: Revision #: Reference Standard Purpose Occupational Safety and Health Administration (OSHA) standard, 29 CFR 1910.39 Subpart E, Fire Prevention Plan This procedure

More information

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM 1 of 213 10/20/2016 11:02 AM Committee Input No. 2505-NFPA 72-2016 [ Global Input ] Change the term visible to visual where appropriate Submitter Information Verification Submitter Full Name: SIG-NAS Organization:

More information

Completed Projects / Projets terminés

Completed Projects / Projets terminés Completed Projects / Projets terminés New Standards New Editions Special Publications Gas Technician Training 2 Module 10, 3rd edition Piping and Tubing Systems for Industrial and Commercial Applications...

More information

NFPA 30 FLC-SWC First Revisions Page 1 of 10 11/6/2015 9:21 AM. First Revision No. 208-NFPA [ Section No ]

NFPA 30 FLC-SWC First Revisions Page 1 of 10 11/6/2015 9:21 AM. First Revision No. 208-NFPA [ Section No ] of 46 11/6/2015 9:21 AM First Revision No. 208-NFPA 30-2015 [ Section No. 9.3.3.1 ] 9.3.3.1 Storage of liquids shall not physically obstruct a means of egress. Submittal Date: Wed Sep 09 18:24:20 EDT 2015

More information

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951) Riverside County Fire Department Office of the Fire Marshal 2300 Market St., Ste. 150, Riverside, CA 92501 Ph. (951) 955-4777 Fax (951) 955-4886 Technical Policy Title: Plant Processing and Extraction

More information

Level I Chapter 1 Worksheet

Level I Chapter 1 Worksheet Chapter 1 Worksheet 1. When the present code requires certain safety to life requirements for existing buildings, those requirements shall. a. be void b. apply c. be approved d. be grand-fathered 2. The

More information

Smoke detection in hazardous areas:

Smoke detection in hazardous areas: WHITE PAPER Smoke detection in hazardous areas: What you need to know Smoke detection in hazardous areas requires detectors that operate effectively and safely in explosive environments. Having the correct

More information

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item Public Comment No. 23-NFPA 96-2015 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM E84, Standard Test Method

More information

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM SECTION 21 10 00 PART 1 - GENERAL 1.1 CODES A. Work shall conform to NFPA 13 Sprinkler Systems, 2002 Edition and NFPA 24 Outside Protection, 2002 Edition. NFPA 14 Standpipe Systems, 2000 Edition and International

More information

RAGAGEP: Codes, Standards, and Good Engineering Practice PETER THOMAS, P.E. PRESIDENT AND ENGINEER RESOURCE COMPLIANCE

RAGAGEP: Codes, Standards, and Good Engineering Practice PETER THOMAS, P.E. PRESIDENT AND ENGINEER RESOURCE COMPLIANCE RAGAGEP: Codes, Standards, and Good Engineering Practice PETER THOMAS, P.E. PRESIDENT AND ENGINEER RESOURCE COMPLIANCE PTHOMAS@RESOURCECOMPLIANCE.COM Introduction PSM RAGAGEP References Title 29 1910.119(d)(3)(ii)

More information

Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ]

Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ] Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard and shall be considered

More information

BUILDING/FIRE CODE REFERENCES 2006 EDITION

BUILDING/FIRE CODE REFERENCES 2006 EDITION BUILDING/FIRE CODE REFERENCES 2006 EDITION This document provides a cross reference with the International Building Code and NFPA 1/Uniform Fire The IBC references the IFC in 97 Code sections. This document

More information

Page 1 of 37 Public Input No. 1-NFPA 30A-2012 [ New Section after 1.1.2 ] 1.1.3 This code shall not apply to aircraft fuel dispensing facilities. NFPA 30A is commonly referenced, in my opinion, incorrectly,

More information

Standards Manager Web Standards List ULC-Underwriters Laboratories of Canada

Standards Manager Web Standards List ULC-Underwriters Laboratories of Canada Standards Manager Web Standards List ULC-Underwriters Laboratories of Canada Id Number Title Year Organization Page 1 ANSI.CAN.UL. NULL 2016 ULC 64 1201 2 CAN.ULC- NULL 2016 ULC 176 60839-11-1-2016 3 CAN.ULC-IEC

More information

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Design and Construction Standards SECTION PLUMBING EQUIPMENT SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES: A. Water heaters. B. Packaged water heating systems. C. Water storage tanks. D. Water softeners. E. Pumps. F. Circulators. 1.2 REFERENCES

More information

NFPA 77 Public Inputs with Responses Page 1 of 15

NFPA 77 Public Inputs with Responses Page 1 of 15 Public Input No. 46-NFPA 77-2016 [ Global Input ] Type your content here... Make universal change from "bonding and grounding" to "bonding or grounding". While "grounding and bonding" is ok in some context

More information

ERRATA TO THE 2000 INTERNATIONAL FIRE CODE. Fourth Printing, January 2002 Updated March 29, 2002

ERRATA TO THE 2000 INTERNATIONAL FIRE CODE. Fourth Printing, January 2002 Updated March 29, 2002 ERRATA TO THE 2000 INTERNATIONAL FIRE CODE Fourth Printing, January 2002 Updated March 29, 2002 Table 2306.2 General Fire Protection and Life Safety Requirements In column 2 (Size of High Piled Storage

More information

Temporary LPG Heat for Construction Sites Work At Risk and Inspection Information Packet

Temporary LPG Heat for Construction Sites Work At Risk and Inspection Information Packet Temporary LPG Heat for Construction Sites Work At Risk and Inspection Information Packet Colorado Springs Fire Department Division of the Fire Marshal December 2013 W:\Packets\Haz Mat\IFC2009_Work_At_Risk_Temp_LPG_Heat

More information

SECTION FUEL-FIRED, DOMESTIC WATER HEATERS

SECTION FUEL-FIRED, DOMESTIC WATER HEATERS SECTION 22 34 00 FUEL-FIRED, DOMESTIC WATER HEATERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Petroleum Gas Systems - 1 -

Petroleum Gas Systems - 1 - Petroleum Gas Systems - 1 - PHMSA's mission is to protect people and the environment by advancing the safe transportation of energy and other hazardous materials that are essential to our daily lives.

More information

Second Revision No. 3-NFPA [ Section No. 2.3 ]

Second Revision No. 3-NFPA [ Section No. 2.3 ] Second Revision No. 3-NFPA 804-2014 [ Section No. 2.3 ] 2.3 Other Publications. 2.3.1 ASME Publications. American Society of Mechanical Engineers, Three Park Avenue, New York, NY 10016-5990. ASME Boiler

More information

Report on First Revision November 2013 NFPA 750

Report on First Revision November 2013 NFPA 750 750 FR1 (Chapter 2) Recommendation: Update the following references: Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard

More information

DuPont Formacel Z-2. Safety and Handling of DuPont Formacel Z-2: Thermoplastic* Foam Extrusion Applications FOAM EXPANSION AGENT TECHNICAL INFORMATION

DuPont Formacel Z-2. Safety and Handling of DuPont Formacel Z-2: Thermoplastic* Foam Extrusion Applications FOAM EXPANSION AGENT TECHNICAL INFORMATION DuPont Formacel Z-2 FOAM EXPANSION AGENT TECHNICAL INFORMATION Safety and Handling of DuPont Formacel Z-2: Thermoplastic* Foam Extrusion Applications Flammability of Formacel Z-2 and Other Alternative

More information

Public Comment No. 7-NFPA 30A-2013 [ Section No ]

Public Comment No. 7-NFPA 30A-2013 [ Section No ] Page 1 of 13 Public Comment No. 7-NFPA 30A-2013 [ Section No. 6.4.2 ] 6.4.2 Additional Proposed Changes Each pump shall have installed on the discharge side a listed leak detection device that will provide

More information

Safety Considerations for Hydrogen Installations

Safety Considerations for Hydrogen Installations Safety Considerations for Hydrogen Installations Nick Barilo PNNL Hydrogen Safety Program Manager Northeast Outreach - April 2016 1 Hydrogen Properties and Behavior A gas at ambient conditions Hydrogen

More information

Handling Petroleum Products & Static Ignition Hazards Introduction

Handling Petroleum Products & Static Ignition Hazards Introduction Handling Petroleum Products & Static Ignition Hazards Introduction Static electricity in one form or another is a phenomenon of nature and often results in electrostatic discharges that can cause fires

More information

ELECTRICAL SAFETY Information Bulletin

ELECTRICAL SAFETY Information Bulletin ELECTRICAL SAFETY Information Bulletin June 2018 CEC-18 [rev-13] Page 1 of 6 CANADIAN ELECTRICAL CODE SUBJECT: Section 18 Hazardous locations Rule 18-006 Locations containing an explosive gas atmosphere

More information

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION CHAPTER 14 FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION SECTION FC 1401 GENERAL 1401.1 Scope. This chapter shall govern fire safety measures during the construction, alteration, or demolition

More information

Plant Processing and Extraction Facilities

Plant Processing and Extraction Facilities Orange County Fire Authority Community Risk Reduction 1 Fire Authority Road, Building A, Irvine, CA. 92602 www.ocfa.org 714-573-6180 Plant Processing and Extraction Facilities Guideline G-16 Serving the

More information

Committee Input No. 60-NFPA [ Sections , ]

Committee Input No. 60-NFPA [ Sections , ] Page 1 of 15 Committee Input No. 60-NFPA 34-2013 [ Sections 3.3.7.1, 3.3.7.2 ] Sections 3.3.7.1, 3.3.7.2 3.3.7.1 Combustible Liquid. A Any liquid that has a closed-cup flash point at or above 100 F (37.8

More information

NFPA 37 Public Comment Responses Page 1 of 32

NFPA 37 Public Comment Responses Page 1 of 32 of 30 11/4/2016 3:05 PM Public Comment No. 6-NFPA 37-2016 [ New Section after 1.6 ] TITLE OF NEW CONTENT Type your content here... 1.7 Pressure Measurement. All pressures expressed in this document are

More information

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1 TO CONTRACT DOCUMENTS ENTITLED: PROJECT MANUAL FOR: Women s and Children s Hospital New Water Service Main PROJECT NUMBER: CP172631 ADVERTISEMENT DATE: July

More information

Page 1 of 19 Committee Input No. 14-NFPA 33-2013 [ Global Input ] Type your content here... Supplemental Information File Name IndoorDraftforCI.docx Description This committee input would be added to new

More information

CHAPTER 45 REFERENCED STANDARDS. number Title section number HB Specification for Highway Bridges, 17th Edition

CHAPTER 45 REFERENCED STANDARDS. number Title section number HB Specification for Highway Bridges, 17th Edition CHAPTER 45 REFERENCED STANDARDS This chapter lists the standards that are d in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard

More information

Second Revision No. 36-NFPA [ Detail ] Submitter Information Verification. Committee Statement 5/18/2015 1:01 PM

Second Revision No. 36-NFPA [ Detail ] Submitter Information Verification. Committee Statement 5/18/2015 1:01 PM of 66 5/18/2015 1:01 PM Second Revision No. 36-NFPA 32-2015 [ Detail ] 6.5 Solvents (See Annex C for additional information on solvents) Submittal Date: Tue Mar 17 17:20:03 EDT 2015 Committee Statement:

More information

The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101):

The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101): The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101): 1.1.1 Title. NFPA 101, Life Safety Code, shall be known as the Life Safety Code, is cited as such, and shall

More information

FIXED PROTECTION FOR OIL AND CHEMICAL PLANTS

FIXED PROTECTION FOR OIL AND CHEMICAL PLANTS GAP.12.2.1.2 A Publication of Global Asset Protection Services LLC FIXED PROTECTION FOR OIL AND CHEMICAL PLANTS INTRODUCTION Fixed water spray, deluge, foam-water and sprinkler systems are essential parts

More information

DOE STANDARD FIRE PROTECTION

DOE STANDARD FIRE PROTECTION NOT MEASUREMENT SENSITIVE DOE-STD-1066-2012 December 2012 Supersedes DOE-STD-1066-99 DOE STANDARD FIRE PROTECTION U.S. Department of Energy Washington, DC 20585 AREA FIRP DISTRIBUTION STATEMENT. Approved

More information

Small LP Gas Jurisdictional Systems. Kim Lapierre Technical Training Manager John Minchew Area Safety Manager West

Small LP Gas Jurisdictional Systems. Kim Lapierre Technical Training Manager John Minchew Area Safety Manager West Small LP Gas Jurisdictional Systems Kim Lapierre Technical Training Manager John Minchew Area Safety Manager West NFPA 58, the Liquefied Petroleum Gas Code standard has been the guidance in the LP Gas/Propane

More information

ELECTRICAL SAFETY Information Bulletin

ELECTRICAL SAFETY Information Bulletin ELECTRICAL SAFETY Information Bulletin February 2014 CEC-18 [rev-11] Page 1 of 9 CANADIAN ELECTRICAL CODE SUBJECT: Section 18 Hazardous Locations Rule 18-006 Division of Class I Locations General For classification

More information

Suggested Specifications Prestige Excellence 110

Suggested Specifications Prestige Excellence 110 Suggested Specifications Prestige Excellence 110 General Requirements A. Furnish and install (qty) completely assembled, modulating, sealed combustion, high efficiency, combination gas-fired boiler(s)

More information

2010 FIRE CODE OF NEW YORK STATE

2010 FIRE CODE OF NEW YORK STATE 2010 FIRE CODE OF NEW YORK STATE CHAPTER 14 FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION SECTION 1401 GENERAL 1401.1 Scope. This chapter shall apply to structures in the course of construction, alteration,

More information

ICC CODE CORNER 2015 International Fire Code

ICC CODE CORNER 2015 International Fire Code SECTION 609 COMMERCIAL KITCHEN HOODS [M] 609.1 General. Commercial kitchen exhaust hoods shall comply with the requirements of the International Mechanical Code. [M] 609.2 Where required. A Type I hood

More information

First Revision No. 15-NFPA [ Chapter 2 ]

First Revision No. 15-NFPA [ Chapter 2 ] Page 1 of 28 First Revision No. 15-NFPA 91-2013 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard

More information

Page 1 of 65 1/29/2016 3:12 PM. Committee Input No. 39-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

Page 1 of 65 1/29/2016 3:12 PM. Committee Input No. 39-NFPA [ Global Input ] Submitter Information Verification. Committee Statement of 36 1/29/2016 3:12 PM Committee Input No. 39-NFPA 1-2015 [ Global Input ] Extracts from the following standards to be updated at the second draft stage: NFPA 10, Standard for Portable Fire Extinguishers,

More information