OWNER S OPERATION MANUAL

Size: px
Start display at page:

Download "OWNER S OPERATION MANUAL"

Transcription

1 DUTY P P STDBY Run 1 2 Run STDBY P P FAULT Run 3 4 OK: Change mode PUMPCONTROL OWNER S OPERATION MANUAL Advanced Multi Pump Controller Installation and Operating Instructions MODEL: FPC S AUTO: RUNNING 475kPa MAIN ISOLATOR DOC: FPC-1507-S VER 1.0

2 CONTENTS 1. Installation I/O Specifications HMI Operation Operational Modes Alarms Logged Data Edit Parameters HMI Config Settings PIN Number mA Display Modes Multi Pump HMI Menu Structure Functionality Base Operation Auto/Off/Manual Manual Mode Timeout Pump Duty Pump Alternate Timer Staggered Pump Start Staggered Pump Stop Anti-Seize Timer Pump Fault Pump Limiting Prime Loss Fault Maximum Idle Timer Maximum Run Fault System Enable Input Level Operation Float Operation High Level Alarm Low Level Alarm Analogue Input Current Loop Fail Alarm Pressure Operation Static Lead Pump Current Loop Reverse High Pressure Alarm Low Pressure Alarm

3 CONTENTS 5. Parameters Listing Modbus Communications Modbus Settings Modbus Physical Connection Modbus Poll and Timeout Settings Modbus Diagnostic Modbus Supported Function Codes Address Reference Data Types Circuit Diagrams Connection Detail At a glance

4 AUTO: RUNNING 475kPa DUTY P P STDBY Run 1 2 Run STDBY P P FAULT Run 3 4 OK: Change mode MAIN ISOLATOR WELCOME TO DUAL PUMP CONTROL Your Advanced Multi Pump Controller reflects the superior quality and attention to detail in design, engineering and manufacturing that has distinguished MATelec Products for decades. The controller incorporates the very latest in micro-processor technology, ensuring you, the owner/ operator, of many years of functional, reliable and user friendly operation. Please read this manual prior to installation and operation of the controller. 1. INSTALLATION 1.1 MOUNTING 1. Controller enclosure must be FRONT Top SIDE VIEW Top mounted in a vertical position. 2. Ensure mounting method does not compromise enclosure weather proof rating. Mounting Frame/ Wall 3. Ensure access to main isolator is not restricted. 4. Ensure cables/conduits entering Bottom Bottom the panel have mechanical protection and that the penetrations are sealed and do not compromise the weather proof rating of the enclosure. WARNING: All electrical connections must be carried out by a suitably qualified and registered electrician SAFETY Prior to Installation, ensure power supply is isolated. Power supply must be Circuit Breaker Protected. (Qualified Electrician to determine appropriate amp rating.) Electrical connection to the panel must be carried out in accordance with Connection Instructions, see page 3. Addition or modifications to the control panel are not permitted and will void warranty. The controller is not intended for use by children or infirm persons without supervision. Repairs to the Controller must only be carried out by a suitably qualified Electrician 4

5 2. I/O SPECIFICATIONS All operator control including pump auto/off/manual is done using the HMI on the front of the panel, which connects via a dedicated, optically isolated serial port. Although the basic configuration will be for float switch based level detection, the system will optionally be configurable to use a 4-20mA hydrostatic pressure transducer. I/O Name Signal Name Description A0 Low level Input from low level float switch A1 Pump stop Input from pump stop level float switch A2 Duty start Input from duty start level float switch A3 Standby 1 start Input from standby 1 start level float switch A4 Standby 2 start Input from standby 2 start level float switch A5 Standby 3 start Input from standby 3 start level float switch A6 Priming Input from priming sensor (opens on prime loss) B0 Pump 1 OK Input from Pump 1 overload. Opens on fault B1 Pump 2 OK Input from Pump 2 overload. Opens on fault B2 Pump 3 OK Input from Pump 3 overload. Opens on fault B3 Pump 4 OK Input from Pump 4 overload. Opens on fault B4 System enable Close contact to enable automatic operation C0 Pump 1 run Output to Pump 1 contactor C1 Pump 2 run Output to Pump 2 contactor C2 Pump 3 run Output to Pump 3 contactor C3 Pump 4 run Output to Pump 4 contactor C4 Siren Siren output C5 Strobe Strobe output C6 Low Level Low Level output D0 Common Fault Common Fault output AI IN Level in 4-20mA level transducer input (optional) AV OUT Level out 0-10V level reference output. Simply copies the input. Table 1 : I/O Listing for standard configuration. 5

6 3. HMI OPERATION AUTO: RUNNING 475kPa DUTY P P STDBY Run 1 2 Run STDBY P P FAULT Run 3 4 OK: Change mode The HMI When power is applied the HMI immediately starts up, displaying a splash screen with the Matelec logo and software revision is displayed for several seconds. Once the splash screen disappears the HMI will then display the main screen which gives an overview of the system. While the HMI is operating it must always be connected to a controller in order to read the necessary data that it needs to display. If it is unable to communicate with the controller the HMI will begin to flash both indicator LEDs and notify the user on the LCD. The user will be unable to operate the HMI until the communication link is restored. During normal operation the user is able to access many different functions related to both the attached controller and the Modbus interface. The following sections present the various menus used by the HMI and describe their use. Navigation between the menu screens is performed using the left and right arrows, which cycles through each of the screens in the following order: 1. Main screen (pump auto/off/manual control) 2. Alarms 3. Input and 4-20mA states 4. View logged data 5. Reset logged data * 6. Edit functional parameters * 7.Edit configuration settings * 8. System information and serial number * * Lines marked with an asterisk require entry of a PIN number for access. See section 3.6 for more info. Note that many of the menu screens feature a prompt along the bottom of the display which outlines basic button functions. 6

7 3.1 OPERATIONAL MODES The system will have three primary modes of operation, which are selected by pressing the okay button on the main screen and pressing up and down to find the mode and okay to select. These modes are outlined below. AUTO: RUNNING 2.6m Change System Mode: AUTO OK: Change mode Off Mode The controller is disabled and will not activate any of the pumps. All alarm conditions are still valid. Auto Mode When the system is set to Auto each of the four pumps will operate as the level rises in the tank. This can either be by float switches or transducer (4-20mA) input. Transducer is selected by setting parameter current loop en = 1. Upon a pump fault that pump will be locked out and the next available pump will be turned on. AUTO: RUNNING 2.6m DUTY Run STDBY Idle P P 1 2 P P 3 4 OK: Change mode STDBY Run FAULT Manual Mode With the system in protected manual mode each pump will be able to be individually selected to run in manual mode. Despite this manual control of the pumps all pump protection algorithms will still be applicable and a faulty pump will still not run. Manual mode ignores the systems enable input. When in manual mode press the up and down arrows select the pump and the OK button to start and stop pump. To return to auto operation, ensure the selection box is around all the pumps (as pictured above) before pressing OK. SYSTEM MANUAL 2.6m P P OFF 1 2 MANUAL Run OFF P P 3 4 : Select Pump FAULT 7

8 3.2 ALARMS The alarms screen reports any alarm conditions and provides the user with a method to reset them. This provides an opportunity for the operator to trigger an alarm test. Pressing the OK button will cause the controller to activate its siren and strobe outputs, plus all LEDs on a keypad (if used) for 5 seconds. After this alarm test is completed the alarms will return to normal operation. ALARMS No alarms active High level Alarm Pump 1 fault ALARMS Press OK to reset alarms Alarms screen with no alarms Alarms screen with multiple alarms If any alarms are active the alarm screen will appear as shown on the right image above and list up to 5 of the active alarms. When an alarm triggers the controller will activate its siren and strobe outputs. The alarm LED on the HMI will also flash. The siren will silence after 5 minutes of continual sounding, however it can be immediately silenced by pressing the mute button on the HMI. Most alarms in the controller are latching, that is the alarm remains active even if the alarm condition has passed / corrected. In order to reset the alarm the OK button needs to be pressed when the Alarms screen is selected. 3.3 LOGGED DATA The logged data screen displays a list of all logged data values from the controller. The up and down buttons are used to scroll through all of the values a small up or down arrow will appear on the top or bottom of the left side of the screen while there is more data available in that direction. LOGGED DATA Pump 1 start count Pump 2 start count Pump 3 start count Logged data screen 3.4 EDIT PARAMETERS The Edit Parameters screen allows the user to modify any of the function parameters in the controller. The parameter that the user wishes to modify is highlighted using the up and down buttons and then OK is pressed in order to edit the selected parameter. Once a parameter has been selected the screen on the image to the right below will be presented and the up and down arrows can then be used to modify the value. The new value can be accepted by pressing OK, otherwise the operation can be canceled by pressing one of the left or right buttons. PARAMETERS Pump stop level 0.5m Pump start level 0.9m Standby 1 level 1.5m PARAMETERS Maximum idle period: 15 mins Use keys to change OK to commit or to cancel Parameter selection screen Parameter modify screen This screen requires entry of the PIN number for editing.(see section 3.6) 8

9 3.5 HMI CONFIG SETTINGS All of the configuration settings related solely to the HMI can be modified through this screen. The Modbus configuration options are pictured below and there are three additional configuration settings in the list: 1. Set analogue range: this setting specifies the maximum range of the level transducer being used to sense the liquid level, based on the level mode selected. For example, if a 0-10m probe is used, then the range would be set to 10m. Alternately, if a kPa probe is used, then the range would be set to 1000kPa. 2. Set analogue type: this setting specifies the level mode for the system - pressure (kpa), level (m). All references to the transducer input will be displayed based on this parameter. 3. Change PIN: selecting this option will allow the PIN number to be changed. Note: There is no way to reset the PIN number if changed, change at your own risk. HMI CONFIGURATION Modbus slave address 1 Modbus speed Modbus parity baud Even Configuration edit screen 3.6 PIN NUMBER In order to modify anything other than the pump auto/off/manual settings, the operator must enter a 4-digit PIN number. Once the PIN is correctly entered, the system remains unlocked for 15 minutes, after which the PIN will need to be entered once again. While unlocked the PIN number can be modified through the configuration settings edit menu. ENTER PIN NUMBER Enter PIN number to enable editing: 0000 Press OK to accept PIN entry screen To enter the PIN number, simply use the left and right buttons to select the value and the up and down buttons to change the digit. The default PIN number is Note that there is no penalty for entering an incorrect PIN the HMI will simply return to the previous screen and the opportunity to enter the PIN will again be presented mA Display Modes When the current loop mode is enabled the HMI is able to report the current 4-20mA reading (this is shown on the inputs menu screen). In addition, it can convert this reading into one of two types of scale: meters or kpa. The meters scale can be adjusted for a maximum range of 0.1 to 25.0 meters (in 0.1m increments) and the kpa scale can be adjusted for a maximum range of 10 to 2500kPa in 10kPa increments. 9

10 3.8 MULTI PUMP HMI MENU STRUCTURE Pin may need to be set to adjust values - Default If not used for a period of time, the pin will need to be entered again. OK OK OK To reset active faults. NUMBER OF PUMPS PUMP 1 START COUNT 10 SYSTEM AUTO OK OK SYSTEM OFF OFF PUMP 4 MAX 0 Reset logged data MANUAL OK STAND BY 3 LEVEL OK CHANGE VALUE 2.4 OK PUMP 1 OFF OK PUMP 1 MANUAL PUMP 2 OFF OK PUMP 2 MANUAL 10

11 4. FUNCTIONALITY Based on the pump mode, operational state and parameter settings each of the four pumps will operate independently in one of eight states: Pump State Applicable Modes Description Off Off Pump will not run Disabled All Pump is disabled by parameter settings and won t run Fault All The Thermal Overload Relay (TOL) for this pump has indicated a fault and has been shut down Manual Run Manual Pump has been set to run in manual mode Standby Idle Auto Pump is not running but available to run if demand requires Standby Run Auto To meet demand this pump has been started in addition to the duty pump Duty Run Auto Pump is the primary operating pump used to maintain the system pressure about the setpoint. If it is unable to keep up with demand then a standby pump will be started in addition to this pump Duty Sleep Auto This pump is the primary pump operating but has been shut off due to no demand. Table 2: Pump State Descriptions Note that the system can be configured for either 2-4 pumps. If only 3 pumps are used ignore references to the fourth pump and stand by 3 start float. Stand by 2 start float will now have the delay for the high level alarm. 4.1 Base Operation Auto/Off/Manual Auto/off/manual control is performed at a system level. If the system is set to auto then it will operate normally. With the system in off the pumps are not operated (however alarms can still be triggered from fault conditions). If set to manual then each pump can individually be selected for manual running. Again, all alarm conditions are still valid in manual mode. If a pump has been temporarily removed from the system (i.e. for replacement) then it should be disabled via the corresponding pump_enable parameter. Manual Mode Timeout The optional Manual Mode Timeout feature prevents the system from being left in manual mode. If the [manual_timeout] parameter is set to a value other than zero then once the system has been in manual mode for that period (in minutes) it will automatically revert back to automatic mode. Pump Duty In order to distribute wear between pumps the system changes duty whenever the duty pump switches off. Pump selection is done sequentially (wrapping around from 4 to pump 1). 11

12 Pump Alternate Timer The [duty_change_time] parameter specifies the time in minutes of continuous running at which a pump alternate occurs. Alternately, setting [duty_change_time] to 0 disables this feature. Staggered Pump Start An undesired characteristic of starting motors DOL is the high inrush and startup current. Starting more than one motor simultaneously (such as during a high level) can put strain on the power supply and cause nuisance tripping. To avoid this a staggered pump start function is available. The controller will always apply the delay set by the [staggered_start_delay] parameter between starting of pumps. Staggered Pump Stop While the staggered start function is designed to minimise wear on the electrical supply to the system, it also reduces water hammer in the connected pipework. Such water hammer can also occur when switching off all pumps simultaneously. In order to again minimise this, the controller will apply the delay set by the [staggered_stop_delay] parameter (in seconds) between stopping each pump. This parameter must be used with caution as it can enable the pumps to run dry. Ensure that the minimum level has ample water to facilitate the staggered stop times. Anti-Seize Timer Some installations will be subject to extended periods of no operation and in such cases it is beneficial to briefly run the pumps periodically in order to prevent them from seizing. The anti-seize feature facilitates this. When anti-seize is enabled and the system is in auto mode, the anti-seize timer will begin timing from the last time that a pump runs. Each time [antiseize_period] hours elapses, an anti-seize operation will be triggered and the duty pump will run for [antiseize_run_time] seconds. This operation ignores all of the float switch inputs (including the low level) and staggered start/stop timers. Following each antiseize run a change of duty is triggered so that each pump will be given an anti-seize operation over time. Setting either the [antiseize_period] or [antiseize_run_time] parameters to zero will disable the anti-seize operation. Pump Fault The unit has four inputs for connection to an overload auxiliary contact from each pump. These contacts are normally closed and open on fault. When a pump fault is detected that pump is immediately locked out and an alarm triggered. The lockout remains latched until the fault is reset this allows the system to work with overloads set to auto-reset. Pump Limiting Some applications require the redundancy of multiple pumps but cannot handle the pipeline pressure generated if all pumps were to be running simultaneously. The [pump_limit] parameter can be set to 2, 3, or 4 pumps and will limit the maximum number of pumps that can be running simultaneously to this value. 12

13 Prime Loss Fault If a pump fails to prime then it should be shut down to prevent damage. A single pressure/flow sensor is used to detect a prime loss condition and thus it is relevant if only the duty pump is running. If only the duty pump is running and the prime loss input is inactive for [prime_loss_delay] seconds then a prime loss fault will be triggered for the duty pump and the system will then alternate. The pump will remain locked out until the fault is reset. If the [prime_loss_delay] parameter is set to zero then the prime loss function is disabled. Maximum Idle Timer The maximum idle timer ensures that the minimum tank level is maintained. When [max_idle_period] minutes has elapsed since any pumps last run and the pump stop input is active then a pump run will be triggered. The duty pump will run until the pump stop input deactivates. Setting [max_idle_period] to zero will disable this feature. Maximum Run Fault A blockage with a pump can cause damage to the pump or the system. When in auto mode the period each pump runs for is timed. If this exceeds [max_run_period] minutes then the system will react as follows. If there are other idle pumps it will immediately alternate and a maximum run alarm for that pump will be triggered. The pump will not be locked out and will run again when called for, but the alarm will remain active until reset. Setting [max_run_period] to 0 disables this feature. If there are no idle pumps available then it will shut down and lock out that pump, requiring manual reset. System Enable Input The system enable input must be closed before the system will operate in automatic mode. Note however that the system mode can still be changed and pumps can still be run in manual mode when the system enable input is open. 4.2 Level Operation Float Operation Up to 6 float switches are used for the base operation: low level, pump stop, duty start, and standby 1-3 start. High level is shared with standby 1,2 or 3 start depending on the number of pumps selected. When in auto mode the operation is based on an order of priority of these float switches, in the order that follows: If the final standby start input is on (standby 2 start in triplex mode, standby 3 start in quadruplex mode) then after the set delay the high level alarm is triggered. If at least one of the other float switch inputs is on then all pumps will be activated. This requirement prevents the pumps from running dry in the event that the high level float were to become stuck on. If the low level input is off and a pump is running then all pumps are immediately switched off. After the set delay the low level alarm is triggered. If [low_level_lockout_en] is set then the pumps will remain locked out until the low level alarm is reset. If the duty start input is active the current duty pump will be turned on. The standby start inputs will activate the corresponding standby pumps in sequence from the duty pump (wrapping around from pump 4 to 1). Note that each input also overrides the input below it. Once activated, pumps remain latched on until the pump stop input turns off. When the duty pump switches off, duty alternates to the next available pump. 13

14 High Level Alarm If the high level input remains on for the time set by the [high_level_delay] parameter (in seconds) then the high level alarm is triggered. The high level alarm is normally latching, but setting [high_level_alarm_reset] to 1 will allow the system to automatically reset high level alarms once the high level input turns off. Low Level Alarm If the low level input is off and any pump start input is on the system will begin timing a low level alarm delay. If this condition remains for the [low_level_alarm_delay] parameter time (in seconds) then the low level alarm will activate. The low level alarm is latching and can only be manually reset. Additionally, if the [low_level_lockout_en] parameter is set to 1 then the system will shut down until the fault is reset. The low level alarm also applies when pumps are being run in manual mode. Analogue Input As an alternative (or in conjunction with) the float switch inputs, an analogue level transducer can be used with the system. The system accepts a 4-20mA transducer by setting [current_loop_en] to 1. The six fluid levels are set to specific transducer output levels using the following parameters: [low_level_current] [pump_stop_current] [duty_start_current] [standby_1_current] [standby_2_current] [standby_3_current] When the level transducer signal reaches the specified level the controller will translate that the same as if the corresponding digital input was activated. In level mode the float switch inputs still function as normal and can override the level sensor. This will allow for example a backup Low Level and High Level float to be used. Note Low Level input is also required for Low Level current input, if not required then Low Level input must be bridged. Also note however that in level mode the high level interlock rules are disabled, so no inputs in addition to the high level need to be active for the high level condition to be acknowledged. Current Loop Fail Alarm When relying on an analogue level probe for operation it is important to know if the probe is faulty. The [loop_fail_alarm_en] parameter, when enabled, will trigger an alarm if the current loop reading drops below 3.5mA. This will not affect operation of the system, but the resulting alarm will latch until reset. 14

15 4.3 Pressure Operation Static Lead Pump Setting [static_lead_pump_en] to 1 will cause the system to always select Pump 1 as the duty pump. Current Loop Reverse Setting [current_loop_reverse] to 1 will cause the system to operate in the reverse manner, i.e. maintaining a set pressure or filling a vessel rather than emptying a vessel. High Pressure Alarm If [current_loop_reverse] is enabled then high pressure alarm operation will be enabled and high level alarm operation disabled. If the analogue input level exceeds [high_pressure_alarm_level] for the time set by the [high_pressure_alarm_delay] parameter (in seconds) then the high pressure alarm is triggered. The high pressure alarm is normally latching, but setting [high_pressure_alarm_reset] to 1 will allow the system to automatically reset high pressure alarms once the high pressure condition subsides. Low Pressure Alarm If [current_loop_reverse] is enabled then low pressure alarm operation will be enabled and low level alarm operation disabled. If the analogue input level drops below [low_pressure_alarm_level] for the time set by the [low_pressure_alarm_delay] parameter (in seconds) then the low pressure alarm is triggered. The low pressure alarm is normally latching, but setting [low_pressure_alarm_reset] to 1 will allow the system to automatically reset low pressure alarms once the low pressure condition subsides. 15

16 5. PARAMETER LISTING Parameter Description Data Range Units Default Number_of_pumps Number of pumps connected to the system Pump_1_enable Enable use of pump Pump_2_enable Enable use of pump Pump_3_enable Enable use of pump Pump_4_enable Enable use of pump Duty_change_period Duty is changed after the duty pump has run for this period of time Minutes 60 Staggered_start_delay Minimum time between pump starts Seconds 3 Staggered_stop_delay Minimum time between pump stops Seconds 1 High_level_alarm_delay Delay before activating high level alarm Seconds 5x60 High_level_alarm_reset If set to 1 high level alarm will reset when high level input turns off Low_level_alarm_delay Delay before activating low level alarm Seconds 5 Low_level_lockout_en Enable system lockout on low level alarm Antiseize_period Delay after pump run for triggering anti-seize run Hours 7x24 Antiseize_run_time Pump run time for anti-seize operation Seconds 5 Manual_timeout Maximum time system remains in manual mode Minutes 5 Pump_limit Maximum number of pumps that can be run simultaneously Prime_loss_delay Delay for prime loss fault. 0 is disabled Seconds 0 Max_run_period Maximum time that the duty pump can be running for. 0 is disabled Minutes 0 Max_idle_period A pump start is triggered after this period. 0 is disabled Minutes 30 Current_loop_en Enable current loop function Loop_fail_alarm_en Enable current loop failure alarm ANALOGUE ANALOGUE Low_level_current Analogue input setting for low level 0.12m RANGE RANGE Pump_stop_current Analogue input setting for pump_stop 0.37m Duty_start_current Analogue input setting for pump 1 start 0.56m Standby_1_current Analogue input setting for pump 2 start 0.75m Standby_2_current Analogue input setting for pump 3 start 0.93m Standby_3_current Analogue input setting for pump 4 start & high level 1.12m State Lead Pump En Pump 1 will always be the duty pump Current Loop reverse As the level decrease pumps, turn on High Pressure Alarm Level Analogue input for high pressure alarm 0 - ANALOGUE ANALOGUE RANGE RANGE 8.50m High Pressure Alarm Delay Delay before activating high pressure alarm Seconds 5 sec High Pressure Alarm Reset If set to 1 High Pressure will reset when below High Pressure Alarm level Low Pressure Alarm Level Analogue input for low pressure alarm 0 - ANALOGUE ANALOGUE RANGE RANGE 1.00m Low Pressure Alarm Delay Delay before activating low pressure alarm Seconds 5 sec Low Pressure Alarm Reset If set to 1 Low Pressure will reset when above low pressure alarm level

17 6. MODBUS COMMUNICATIONS Modbus is a serial communications protocol originally designed for use PLCs. Simple and robust, it has since become one of the de facto standard communications protocols in the industry, and it is now amongst the most commonly available means of connecting industrial electronic and control devices. Through it s connected ME16 HMI, the ME21 supports Modbus communications as described here. There are several different variations of the Modbus standard based around the transmission mode and data encoding technique. The protocol supported by the ME16 is Modbus RTU, which is a binary format sent over a serial link. The ME16 is configured as a Modbus slave and responds to commands sent to it from the Modbus master. 6.1 Modbus Settings In order to reduce unnecessary complexity, the system will comply only with the BASIC Modbus implementation class but with some additional features, as detailed in the following table. All settings have a default which is valid until the operator changes them via configuration menu. Setting Implemented Default Address Configurable from 1 to Baud Rate 9600, Parity Even, Odd, None Even HMI CONFIGURATION Modbus slave address 1 Modbus speed baud Modbus parity Even 6.2 Modbus Physical Connection The ME16 provides a three pin pluggable terminal for connection of the three RS- 485 connections required for the Modbus interface: A, B and GND. As with the other ME16 connections the wiring information is printed on the rear label of the unit. 6.3 Modbus Poll and Timeout Settings The poll rate is how often the Modbus master requests information from the slave. Since the processor on the ME16 must also operate the user interface and continually operate the communication link with the connected controller, it is only able to cope with a limited number of Modbus transactions per second. The recommended maximum poll period of 500ms (2 polls per second), however a period of 1 second is preferred. Periods as low as 250ms can be achieved but there can be no guarantee as to the ME16 s ability to respond at this rate (particularly with write commands). Certain Modbus operations require the ME16 to initiate further communications with the attached controller and this can take significantly more time than other operations for the controller to respond. For this reason a timeout period of no less than 1000ms should be used. If the Modbus connection is being used for monitoring only (rather than monitoring and control) then the timeout can be reduced to 500ms. 17

18 6.4 Modbus Diagnostics The System Information screen on the HMI can be used to diagnose the Modbus communication channel. Whenever a Modbus packet is received the Modbus Diag line will momentarily report Modbus Diag: Data Rx for 500ms. This will prove that the physical RS-485 connection is functional. If the received packet caused a modbus exception to be generated then it will also be temporarily reported as follows: Parity Error: Parity Error Baud Rate/Serial Port Error: UART Error Function Not Supported: Bad Function Illegal Data Address: Data Bad Addr Illegal Data Value: Bad Data Val Slave Device Failure: Slave Failure The error message is displayed for 20 seconds after the event occurs. 6.5 Modbus Supported Function Codes The Modbus protocol uses function codes to perform actions such as reading and writing the different physical data types. Only a portion of the full range of function codes is used, as outlined in the following table: Function Code Description Valid Address Range 01 Read coils 1 to Read holding registers 1 to Write single register 1 to Write multiple registers 1 to Address Reference The following table lists all valid Modbus coil and register addresses for the ME21 and the data contained within: Logged Values Register Address First Coil Address Data Range Data Type ID_number[0] ASCII ID_number[1] ASCII ID_number[2] ASCII ID_number[3] ASCII ID_number[4] ASCII ID_number[5] ASCII ID_number[6] ASCII ID_number[7] ASCII Number_of_pumps Number Pump_1_enable Number Pump_2_enable Number Pump_3_enable Number Pump_4_enable Number 18

19 Values Register Address First Coil Address Data Range Data Type Duty_change_period Minutes Staggered_start_delay Seconds Staggered_stop_delay Seconds High_level_alarm_delay Seconds High_level_alarm_reset Number Low_level_en Number Low_level_alarm_delay Seconds Antiseize_period Hours Antiseize_run_time Seconds Manual_timeout Minutes Pump_limit Number Prime_loss_delay Seconds Max_run_period Minutes Max_idle_period Minutes Current_loop_en Number Loop_fail_alarm_en Number Low_level_current Current x10 Pump_stop_current Current x10 Duty_start_current Current x10 Standby_1_current Current x10 Standby_2_current Current x10 Standby_3_current Current x10 Spare Logged Values Register Address First Coil Address Data Range Data Type Pump_1_start_count Number Pump_2_start_count Number Pump_3_start_count Number Pump_4_start_count Number Pump_1_run_hours Hours Pump_2_run_hours Hours Pump_3_run_hours Hours Pump_4_run_hours Hours Pump_1_fault_count Number Pump_2_fault_count Number Pump_3_fault_count Number Pump_4_fault_count Number Power_cycle_count Number High_level_count Number Low_level_count Number P1_max_run_count Number P2_max_run_count Number P3_max_run_count Number P4_max_run_count Number P1_prime_fault_count Number P2_prime_fault_count Number P3_prime_fault_count Number P4_prime_fault_count Number Spare

20 System Values Register Address First Coil Address Data Range Data Type System_mode : Off NUMBER 1: Auto 2: Manual Pump_1_man_run NUMBER Pump_2_man_run NUMBER Pump_3_man_run NUMBER Pump_4_man_run NUMBER Fault_reset NUMBER Mute_flag NUMBER Spare System_state : Off 1: Manual 2: Startup 3: Running 4: Lockout 5: Disabled 6: Powerup Delay NUMBER Pump_1_state Pump_2_state Pump_3_state Pump_4_state : Off 1: Disabled 2: Standby Idle 3: Standby Run 4: Duty Idle 5: Duty Run 6: Manual Run 7: Fault 8: Starting 9: Stopping 10: Antisieze Run NUMBER Input_states BINARY Output_states BINARY Analog_in CURRENT x10 Analog_out VOLTAGE x10 Alarm_states BINARY System_lockout BINARY Firmware_rev[0] ASCII Firmware_rev[1] ASCII Firmware_rev[2] ASCII Firmware_rev[3] ASCII System_powerup_timer ASCII Spare Table 3: Modbus registers, firmware revision

21 6.7 Data Types Number Number values are numeric values in the range specified. Current Current values represent any parameter relating to the analogue input. Current is used here as it represents the base format of the analogue input. Because Modbus only supports integer values, the numeric value in these registers represents the measured current multiplied by ten. To convert between the register value and other units please use the following table: Units Convert From Register Value Convert To Register Value Actual Current (ma) register_value 10 actual_current x 10 Pressure (kpa) ( register_value - 40) x sensor_range 160 pressure x 160 sensor_range + 40 Level (m) (register_value - 40) x sensor_range 160 level x 160 sensor_range + 40 Temperature ( C) (register_value - 40) x sensor_range 160 temperature x sensor_range Voltage Voltage values represent parameters relating to the analogue output and pump speed. Voltage is used here because it is the native unit of the analogue output. Because Modbus only supports integer values, the numeric value in these registers represents the measured voltage multiplied by ten. To convert between the register value and other units please use the following table: Units Convert From Register Value Convert To Register Value Actual Voltage (V) Speed (Hz) register_value 10 register_value 10 actual_value x 10 speed x 2 21

22 ASCII These registers contain the ASCII code for characters used in the unit s ID number (or serial number). These ASCII values have a range of 48 to 255 (0x30 to 0xff), however note that the HMI can only display ASCII characters in the range of 48 to 126 (0x30 to 0x7e). The following ASCII table shows these characters: Binary States Input states, output states, alarm states and fault lockout states have information in binary form as shown in the following table. Each of the individual addresses can be accessed as a coil (using the specified coil address) or as an individual bit of that register (bit 0 is the least significant bit, on the right). Register Bit Coil Address Input State A A A A A A A B B B B B Unused 22

23 Register Bit Coil Address Output State C C C C C C C D Unused Register Bit Coil Address Input State Pump 1 fault Pump 2 fault Pump 3 fault Pump 4 fault High Pressure Fault Low Pressure Fault Pump 1 Max Run Pump 2 Max Run Pump 3 Max Run Pump 4 Max Run Current Loop Pump 1 Prime Loss Pump 2 Prime Loss Pump 3 Prime Loss Pump 4 Prime Loss Bad Data Load 23

24 FPC-SERIES 7. CIRCUIT DIAGRAM FPC S Three Phase, Single Pump Controller c/w Floats 415 Vac Supply L1 L2 L3 E N WARNING! MSW1 Main Isolator MAXIMUM OF 10 STARTS PER HOUR FOR EACH PUMP CB2 C1 L1 T1 TOL1 SS1 P1 Circuit Breaker D' Curve 3P L2 T2 L3 T3 Contactor 3P Thermal Overload ABB SOFT STARTER ST A1 A2 P2 P3 P1 415V Pump R1/1 CB1 Circuit Breaker T1 L N PE 24Vdc Power Supply +24 Vdc -24 Vdc + - SS1 COM RUN C1 A1 A2 Contactor 24Vdc R1 PCB1 COM D0 Relay 24Vdc 2P BZ1 Buzzer Common Fault BMS Voltage Free F1 Fuse 1A ST1 X1 X2 Strobe Light COM RX TX +24Vdc -24Vdc PCB1 HMI1 TOL NC Contact Pump 1 Thermals Low Level Stop Level Start Level High Level Float Float Float Float INPUTS 24Vdc 24

25 FPC-SERIES FPC S Three Phase, Single Pump Controller c/w Transducer 415 Vac Supply L1 L2 L3 E N WARNING! MSW1 Main Isolator MAXIMUM OF 10 STARTS PER HOUR FOR EACH PUMP CB2 C1 L1 T1 TOL1 SS1 P1 Circuit Breaker D' Curve 3P L2 T2 L3 T3 Contactor 3P Thermal Overload ABB SOFT STARTER ST A1 A2 P2 P3 P1 415V Pump R1/1 CB1 Circuit Breaker T1 L N PE 24Vdc Power Supply +24 Vdc -24 Vdc + - SS1 COM RUN C1 A1 A2 Contactor 24Vdc R1 PCB1 COM D0 Relay 24Vdc 2P BZ1 Buzzer Common Fault BMS Voltage Free F1 Fuse 1A ST1 X1 X2 Strobe Light Optional Analogue OUT COM RX TX +24Vdc -24Vdc 0-10V PCB1 HMI1 E + - Level Transducer 4-20mA TOL NC Contact Pump 1 Thermals Low Level Float High Level Float INPUTS 24Vdc 25

26 8. CONNECTION DETAIL FPC S Three Phase, Single Pump Controller c/w Floats E A1 A2 A3 SUPPLY 415Vac Connections N T1 T2 Pump 1 T SWITCH Input 1 Low Level Input 2 Stop Level Input 3 Start Level INPUT SWITCHES 24Vdc Connections Input 4 High Level COMMON FAULT BMS VOLT/FREE PUMP 1 Earth P1 P2 PUMP 1 P3 415Vac MAINS POWER SUPPLY BRIDGE IF NOT REQUIRED BLUE NOT REQUIRED COMMON N/O CLOSE ON RISE BLUE NOT REQUIRED COMMON N/O CLOSE ON RISE BLUE NOT REQUIRED COMMON N/O CLOSE ON RISE BLUE NOT REQUIRED COMMON N/O CLOSE ON RISE REMOVE BRIDGING WIRE TO USE LOW LEVEL LOW LEVEL ALARM STOP LEVEL START LEVEL HIGH LEVEL PUMP 1 26

27 FPC S Three Phase, Single Pump Controller c/w Transducer + - E A1 A2 A3 SUPPLY 415Vac Connections N T1 T2 Pump 1 T SWITCH 24Vdc SHIELD EARTH Level Transducer 4-20mA Input 1 Low Level Input 4 High Level INPUT SWITCH 24Vdc Connection COMMON FAULT BMS VOLT/FREE PUMP 1 Earth P1 P2 PUMP 1 P3 BRIDGE IF NOT REQUIRED BLUE NOT REQUIRED COMMON N/O CLOSE ON RISE BLUE NOT REQUIRED COMMON N/O CLOSE COMMON ON RISE 415Vac MAINS POWER SUPPLY SHIELDED TRANSDUCER CABLE Current loop enabled to use transducer (see page 6) LOW LEVEL HIGH LEVEL PUMP 1 HYDROSTATIC LEVEL TRANSDUCER 27

28 AT A GLANCE A quick reference to the controller s HMI and Indicator functions and meanings. AUTO: RUNNING 475kPa DUTY Run P P 1 2 STDBY Run STDBY Run P P 3 4 FAULT OK: Change mode The HMI - Scroll through main pages - Changes digit when adjusting values - Change pump selection 1 or 2 on main page - Scroll through page list - Changes number when adjusting values - Change pump mode on main page OK - Select and saves value 'to be changed' - Access pump mode adjustment on main page - Reset system faults on alarm page MUTE - Mutes active audible alarm. DISTRIBUTED BY: INSTALLATION DATE: SERIAL NUMBER: MANUFACTURED BY MATelec AUSTRALIA info@matelecaustralia.com.au MATelec reserves the right to alter technical specifications without notice 28

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design TOTAL SOLUTIONS Liquid Level Control Product Guide MATELEC innovative by design Liquid Level Control Contents Dual Pump Controllers Section 1 The Range Common Features Operating Data Control Logic Setup

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option SM3000 Videographic Recorder User Guide (RTU) Communications Option ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow

More information

PTE0705 Electric Fence Monitor

PTE0705 Electric Fence Monitor PTE0705 Electric Fence Monitor The JVA logo is a registered trademark of JVA Technologies. JVA Technologies. TABLE OF CONTENTS DESCRIPTION... 2 QUICK START GUIDE... 3 FEATURES... 4 EXPLANATION OF TERMS...

More information

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1 NGC-40 Bridge Overview Raychem-AR-H58862-NGC40BridgeOV-EN-1805 nvent.com 1 Table of Contents 1. NGC-40 Overview... 9 1.1 Example NGC-40 System... 10 2. Legal stuff... 11 3. Protocols... 12 3.1 Data es...

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

RS485 MODBUS Module 8AI

RS485 MODBUS Module 8AI Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS) USER MANUAL Protec Fire Detection plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT, ENGLAND +44 (0) 1282 717171 www.protec.co.uk

More information

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER This manual must be left with owner and should be hung on or adjacent to the boiler for reference. US HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER MODELS CHS-85 through CHS-399 APPENDIX A CONTROLLER

More information

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com FL500 Modbus Communication Operating Manual Order No.: 10193214/00 MSAsafety.com 1000 Cranberry Woods Drive Cranberry Township, PA 16066 A Phone 1-800-MSA-2222 Fax 1-800-967-0398 For your local MSA contacts

More information

ZSC100 Gas Detection and Alarm System Controller

ZSC100 Gas Detection and Alarm System Controller ZSC100 Gas Detection and Alarm System Controller User Guide 1- Introduction... 3 1.1- General description... 3 1.2- Cautions and warnings... 3 2- Control panel... 4 2.1 Control panel overview... 4 2.2

More information

Flopurge TS. Operation Manual

Flopurge TS. Operation Manual Flopurge TS Operation Manual Part Number 079-0204 Spectron Gas Control Systems United Kingdom Unit 4, Herald Court, University of Warwick Science Park, Coventry, CV4 7EZ +44 (0)24 7641 6234 sales@spectron-gcs.com

More information

Ethernet General Purpose

Ethernet General Purpose Ethernet General Purpose Technical Manual Revision 1.03 8 November 2013 Pakton Technologies IO PAE224 Ethernet GPIO Manual.docx Page 1 of 22 Revision 1.03 Last updated 8/11/2013 Table of Contents INTRODUCTION...3

More information

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual Revision 1.03 8 November 2013 JVA Technologies Ethernet General Purpose IO Technical Manual www.jva-fence.com.au Table of Contents INTRODUCTION...3 Scope and Purpose...3 Glossary...3 SPECIFICATIONS...4

More information

user manual Document No , Revision 03 November 2015

user manual Document No , Revision 03 November 2015 user manual Document No. 996-202-600-3, Revision 03 November 2015 Contents 1 Introduction...1 1.1 Notice...1 1.2 Models...1 2 User Control Levels...2 2.1 Level Definition...2 2.2 User Passwords...2 3 Controls

More information

Dryer Controller M720

Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,

More information

Operation Manual. Programmable Logic Controller

Operation Manual. Programmable Logic Controller Operation Manual Programmable Logic Controller Part No. 9983-0000-E01 / January 2018 OPERATION MANUAL TABLE OF CONTENTS CUSTOMER SERVICE 3 CONTACT INFORMATION 3 ORDER INFORMATION 3 INTRODUCTION 4 THE PROCESS

More information

User Manual. Dryer Controller M720

User Manual. Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009

More information

Installation Manual Tracker 221

Installation Manual Tracker 221 Installation Manual Tracker 221 KSR KUEBLER AG Im Kohlstatterfeld 17 D-69439 Zwingenberg / Germany www.ksr-kuebler.com Contents About this Installation Manual...4 Description Tracker 220-series...4 Installing

More information

21-light Remote Annunciator. Owner s Manual

21-light Remote Annunciator. Owner s Manual 21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With

More information

F Technical Bulletin SC 370 SMART Modbus Interface

F Technical Bulletin SC 370 SMART Modbus Interface F7904502 Document Revision History Document Versiosion Modbus Map Ver- Date Author Notes 1 10 9/26/17 JGG Document Created Flash Technology, 332 Nichol Mill Lane, Franklin, TN 37067 www.flashtechnology.com

More information

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08 Beacon 200 Gas Monitor Operator s Manual Part Number: 71-2102RK Released: 6/6/08 Table of Contents Chapter 1: Introduction.................................................3 Overview.............................................................3

More information

Flostop TS D7E and A8E. Operation Manual

Flostop TS D7E and A8E. Operation Manual Flostop TS D7E and A8E Operation Manual United Kingdom Spectron Gas Control Systems Ltd, Unit 4, ATU1, University of Warwick science Park, Coventry, +44 (0) 24 7641 6234 sales@spectron-gcs.com Germany

More information

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems Honeywell Life Safety Iberia C/Pau Vila 15-19; 08911 Badalona Barcelona T. 902 03 05 45; Internacional:+34932424236 www.honeywelllifesafety.es infohlsiberia@honeywell.com ibox Modbus Server Gateway for

More information

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

La Marche Manufacturing Company   Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual La Marche Manufacturing Company www.lamarchemfg.com Option 46 Series Digital Combined Accessory Package Installation and Operation Manual This manual is subject to change without notice. You may obtain

More information

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas User s Manual TIGER S EYE E-Series Mark V Jockey TIGERFLOW Systems, Inc. 4034 Mint Way Dallas, Texas 75237 214-337-8780 www.tigerflow.com TABLE OF CONTENTS Introduction... 4 Sequence of Operation... 5

More information

Lift Station Level Controller

Lift Station Level Controller Lift Station Level Controller Installation and Operation Manual 1 California Motor Controls, Inc. Benicia, CA Table of Contents 1. Features Product Overview... 4-6 Access Security... 7 Optional Features...

More information

Installation and Operation Manual

Installation and Operation Manual SENTRY Protect Plus QUADPLEX PANEL Installation and Operation Manual For Hardwired Pumps Environment e Corporation Table of Contents 1 Overview...3 2 Sentry Protect Plus Quadplex Menu Flowchart...4 3 Wiring

More information

CTT8 TEMPERATURE MONITOR DEVICE

CTT8 TEMPERATURE MONITOR DEVICE INSTRUCTION MANUAL IM302-U v2.3 CTT8 TEMPERATURE MONITOR DEVICE GENERALITY The device of control temperatures CTT8 is used in the control of electric machine, transformer, motor, etc. where it s possible

More information

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA 99336 www.jmcvr.com 1-509-586-9893 Table of Contents TABLE OF FIGURES...1 OVERVIEW OF THE HRC CAPABILITIES...2 INSTALLATION AND

More information

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV CyCLO User Guide Version 2.00 19 th December 2017 REV 2.00 1 Contents 1. Hardware... 3 1.1. Introduction... 3 1.2. Electrical Specification... 3 1.3. Board Overview... 4 1.4. Electrical Installation...

More information

P2267 NETWORK INTERFACE

P2267 NETWORK INTERFACE P2267 NETWORK INTERFACE USER MANUAL FOR OPERATING SYSTEMS: 22031-03 23636-01 October 2009 Associated Controls (Australia) Pty. Limited 2-4 Norfolk Road Greenacre, NSW, 2190. PH +61 2 9642 4922, FAX +61

More information

CLEANROOM MONITOR CR3A Network - Installation Instructions

CLEANROOM MONITOR CR3A Network - Installation Instructions CLEANROOM MONITOR CR3A Network - Installation Instructions INTRODUCTION The CR3 Series Cleanroom Monitor, was developed specifically to allow for monitoring of confined spaces with accuracy and reliability.

More information

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual ZX1e ZX2e ZX5e Document No. 996-130 Issue 01 user manual MORLEY-IAS ZX2E/ZX5E Fire Alarm Control Panels Table of Contents 1 INTRODUCTION... 4 1.1 NOTICE... 4 1.2 WARNINGS AND CAUTIONS... 4 1.3 NATIONAL

More information

725B Configuration Software Manual

725B Configuration Software Manual 725B Configuration Software Manual REV DATED DESCRIPTION AUTHOR APPROVED 0 09-03-10 First Issue P.Cartmell Page 1 of 80 SECTION 1 - SOFTWARE INSTALLATION... 5 725B ConfigurationSoftware Installation...

More information

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504 Remote Monitor PTE0700 SECURITY ELECTRONICS User Manual PTE0700 V2 Series Remote Monitor Pakton Technologies Pty Ltd ABN 66 405 694 842 16 Ferrier Road, Narangba Qld 4504 PO Box 408, Narangba QLD 4504

More information

EasyTronic III MANUAL SERVICE

EasyTronic III MANUAL SERVICE rev.6 EasyTronic III MANUAL SERVICE General characteristics: Power supply 24 Vac ±15% Max consumption at 24Vac 300mA Relay outputs 6 Maximum relay current 8 A res. Serial standard RS232 2 Serial standard

More information

MO n : 12JMC rév A

MO n : 12JMC rév A CTT8 MO n : rév A Page 2 / 18 MODIFICATIONS Rev. Description Date Checked by Approuved by Z Creation 2012/02/12 JMC LA A First issue 2012/02/14 JMC LA INDEX Page 3 / 18 GENERALITY 4 INTRODUCTION 4 ACCESSORIES

More information

COCB_ Circuit Breaker (2 state inputs/ 2 control inputs)

COCB_ Circuit Breaker (2 state inputs/ 2 control inputs) MRS752348-MUM Issued: 0/997 Version: F/23.6.2005 Data subject to change without notice COCB_ Circuit Breaker (2 state inputs/ 2 control inputs) Contents. Introduction... 3. Features... 3.2 Application...

More information

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer Installation and interface must be performed by a qualified controls technician. IMPORTANT: THIS MANUAL CONTAINS INFORMATION REQUIRED FOR INSTALLATION, INTERFACE AND CONFIGURATION OF THIS EQUIPMENT. READ

More information

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training PowerWizard Level 1.0 & Level 2.0 Control Systems Training New Systems Current Systems Systems Comparison Level 1 Level 2 Level 3 Level 4 PowerWizard Level 3.0 PowerWizard Level 4.0 Overview Common parts

More information

Refrigerated air dryers

Refrigerated air dryers Refrigerated air dryers OPERATING AND MAINTENANCE MANUAL Original instructions 38178800319 OPERATING AND MAINTENANCE MANUAL - Contents 1 CONTENTS CONTENTS... 1 Chapter 1 IDRY ELECTRONIC CONTROLLER...

More information

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL USER MANUAL 1 Table of Contents 1 SAFETY INFORMATION...3 1.1 SAFETY PRECAUTIONS DURING NORMAL OPERATION OF PANEL...3 1.3 BATTERY INFORMATION...3

More information

M2500 Engine Controller Installation Manual

M2500 Engine Controller Installation Manual M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...

More information

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd Product Data Sheet Mx-4000 Series User Manual MX-4100, MX-4200, MX-4400, Mx-4400/LE & Mx-4800 Fire Alarm Control Panels The operation and functions described in the manual are available from Software Versions

More information

USER MANUAL FOR OPERATING SYSTEM

USER MANUAL FOR OPERATING SYSTEM P2262 ALARM PANEL USER MANUAL FOR OPERATING SYSTEM 21765-07 September 1999 Associated Controls (Aust) PTY. LTD. 29 Smith Street, Hillsdale, NSW, 2036. PH (02) 9311 3255, FAX (02) 9311 3779 Page 1 of 177

More information

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE General Description This guide provides a summary for installing and configuring the Centaur TM Cube Slave Alarm Signalling Equipment

More information

General Purpose IO Technical Manual

General Purpose IO Technical Manual General Purpose IO Technical Manual Revision 1.06 8 November 2013 Pakton Technologies PAE222 GPIO Manual.docx Page 1 of 21 Revision 1.06 Last updated 8/11/2013 Table of Contents INTRODUCTION...3 Scope

More information

VTI MODEL itc5000 HEAT TRACING CONTROL SYSTEM OPERATIONS MANUAL

VTI MODEL itc5000 HEAT TRACING CONTROL SYSTEM OPERATIONS MANUAL VTI MODEL itc5000 HEAT TRACING CONTROL SYSTEM OPERATIONS MANUAL 1 Operations Manual for the VTI Model itc5000 Heat Tracing Control System Description The VTI Model itc5000 Heat Tracing Control System consists

More information

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Process & TeMPerATUre UniversAl input DigiTAl MeTers Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min

More information

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL The LeakMonitor alarm panel is a microprocessor controlled fully adjustable alarm system suitable for multizone

More information

Instruction Manual Model Backup Switch, 1 for 8

Instruction Manual Model Backup Switch, 1 for 8 Instruction Manual Model 2582-282 Backup Switch, 1 for 8 December 2011, Rev. 0 MODEL 2582 SWITCH CROSS TECHNOLOGIES INC. SWITCH ALARM PSA PSB ALARM OFFLINE ONLINE UNIT STATUS 1 2 3 4 5 6 7 8 BU PROT MODE

More information

Beacon 800 Gas Monitor Operator s Manual

Beacon 800 Gas Monitor Operator s Manual Beacon 800 Gas Monitor Operator s Manual Part Number: 71-0037RK Revision: F Released: 4/18/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to be

More information

HERCULES 6 GRAPHICS SYSTEM

HERCULES 6 GRAPHICS SYSTEM HERCULES 6 GRAPHICS SYSTEM USER MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273 Web: www.protec.co.uk

More information

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL MYRIAD TPC VISIT OUR WEBSITE SIGMACONTROLS.COM MYRIADI&O062705 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING 7,8

More information

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION Environment IMPORTANT INFORMATION It is not anticipated that this equipment will be exposed to adverse environmental conditions without additional protection. Site the equipment in a frost free area. Ensure

More information

RPM1600 Series Room Pressure Monitors

RPM1600 Series Room Pressure Monitors RPM1600 Series Room Pressure Monitors Technical Bulletin LB-RPM1611-0, LB--0 Code No. LIT-12012228 Issued October 2017 Refer to the QuickLIT website for the most up-to-date version of this document. How

More information

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

ECO N DATE DESCRIPTION OF CHANGE CHG

ECO N DATE DESCRIPTION OF CHANGE CHG Model Number: M21E-24-DIN Description: The product is a loop powered device which controls an unsupervised dual pole output channel suitable to manage 24VAC loads. The M21E-24-DIN is micro-controller operated,

More information

PF1000 CONTROLLER. for the. Heateflex Corporation 405 E. Santa Clara St. Arcadia, CA TEL: (626) ; FAX: (626)

PF1000 CONTROLLER. for the. Heateflex Corporation 405 E. Santa Clara St. Arcadia, CA TEL: (626) ; FAX: (626) PF1000 CONTROLLER for the AQUARIUS I/II DEIONIZED WATER HEATING SYSTEM Heateflex Corporation 405 E. Santa Clara St. TEL: (626)599-8566; FAX: (626)599-9567 Rev. 07 10/19/10, (PF1000) 1 2 TABLE OF CONTENTS

More information

Micro-VPAC IIT LSC - Lift Station Controller. User Manual. Version 1.0.2

Micro-VPAC IIT LSC - Lift Station Controller. User Manual. Version 1.0.2 Micro-VPAC IIT LSC Micro-VPAC IIT LSC - Lift Station Controller User Manual Version 1.0.2 Table of Contents ii CHAPTER: Table of Contents Contents Introduction 5 General 6 Control Description 6 Manual

More information

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual Syncro AS Analogue Addressable Fire Control Panel User Manual Man-1100 Issue 02 Nov. 2008 Index Section Page 1. Introduction...3 2. Safety...3 3. Panel Controls...4 3.1 Access Level 1...4 3.2 Access Level

More information

Open Protocol Data Communications

Open Protocol Data Communications MicroTech Series-100 Centrifugal Chiller Open Protocol Data Communications Information Packet Version 3.2 April, 1996 - C O N F I D E N T I A L - This Document may not be copied or reproduced in any way

More information

Q-SMART MODBUS KIT. Modbus Protocol & Parameters. Cod EN rev.a ed.08/2018. Q-SMART Software Version AE17

Q-SMART MODBUS KIT. Modbus Protocol & Parameters. Cod EN rev.a ed.08/2018. Q-SMART Software Version AE17 Q-SMART MODBUS KIT Modbus Protocol & Parameters Cod.001085120EN rev.a ed.08/2018 Q-SMART Software Version AE17 Index 1 Modbus Protocol on Q-SMART... 4 1.1 Broadcasting... 4 1.2 Data Protection... 4 1.3

More information

Watchguard WGAP864 User Manual

Watchguard WGAP864 User Manual Watchguard WGAP864 User Manual v1.0 Issued September 2016 1 2 Table of Contents Glossary... 5 1. Introduction to your Watchguard WGAP864... 6 2. Before Operating your Alarm System... 6 3. Understanding

More information

Planning Elevator Relay Groups Programming Millenium for Windows Software

Planning Elevator Relay Groups Programming Millenium for Windows Software Installation Booklet: Elevator Control Unit (ECU) Introduction The Elevator Control Unit (ECU) is an option in the Millenium for Windows systems. Once you add an elevator in the software, each elevator

More information

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - TriMax prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

APP 721 MODBUS Mapping

APP 721 MODBUS Mapping SUMMARY This document is intended to be a reference for communicating with the Flygt APP721 controller using MODBUS RTU communication. Communication settings to the unit are as follows: MODBUS RTU, 8 data

More information

HTC-915 Installation & operating manual

HTC-915 Installation & operating manual HTC-915 Installation & operating manual 915 SERIES PE N L To external alarm annunciater / DCS or PLC input Max 3A 250V CT input To external alarm annunciater / DCS or PLC input Max 3A 250V 21 20 19 18

More information

Transfer Switch Features

Transfer Switch Features 1-1 Product Description The Automatic Transfer Switch Option may be added to any FD type Fire Pump Controller whenever automatic transfer from normal to alternate power is required. The automatic Transfer

More information

Tri-Stack Smart System

Tri-Stack Smart System Tri-Stack Smart System TM Notes & Warnings - The protection provided by this equipment may be impaired if it is not used in the manner specified herein. - Ensure all wiring meets applicable national and

More information

ALARM SYSTEM USER S MANUAL Rev

ALARM SYSTEM USER S MANUAL Rev ALARM SYSTEM USER S MANUAL Rev.06 890-00011 Manufacturer: Viatron Electronics 3514 1st Street, St-Hubert (Quebec) Canada J3Y 8Y5 WARNINGS the warranty can be void if the Agri-Alert 2400 is used in a manner

More information

DAP III Zone Master User s Guide

DAP III Zone Master User s Guide DAP III Zone Master User s Guide Data Aire, Inc. 230 West BlueRidge Avenue Orange, California 92865 Document Number 600-000-788 March 2010 Revision 1.0 Document # 600-000-788 1 Overview The Data Aire DAP

More information

prestige Control Application Supplement - ACVMax

prestige Control Application Supplement - ACVMax 2015-10 Prestige ACVMax Control Sup 12-14-15_ACVMax_Control 12/15/15 7:36 AM Page 1 prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory

More information

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47) DIESEL ENGINE CONTROL UNIT DCU 205 - USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) 64 84 52 00 Fax: (+47) 64 84 52 12 office@auto-maskin.no - 1 - TABLE OF CONTENTS 1. INTRODUCTION TO THE DCU 205...4

More information

Gas Detection System TOX ALARM DG2000-Garage

Gas Detection System TOX ALARM DG2000-Garage Gas Detection System TOX ALARM DG2000-Garage Gas Detection System 32 independent programmable channels 2 programmable alarm levels for each gas = up to 6 for each channel LCD alphanumeric display of gas

More information

SCAN200E USER S MANUAL

SCAN200E USER S MANUAL SCAN200E USER S MANUAL Code No. 2071 1052 rev. 1.4 Code No. 2071 1052 Rev. 1.4 Page 2/16 SCAN200E User s Manual Foreword This manual is for SCAN200E Controller running software version 2.03 or later. We

More information

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel DS9400 Series EN Release Notes for Firmware V2.07 Fire Alarm Control Panel DS9400 Series Release Notes for Firmware V2.07 Trademarks Trademarks Gentex is a trademark of Gentex Corporation, Fire Protection

More information

Product Manual SZ1145

Product Manual SZ1145 Product Manual SZ114 General Purpose Monitor Communicating Controls Description The SZ114 is a microprocessor-based monitoring and alarm interface designed to monitor up to four 1000 Ω platinum temperature

More information

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...

More information

RTD TEMPERATURE SENSING SYSTEM

RTD TEMPERATURE SENSING SYSTEM General Overview RTD TEMPERATURE SENSING SYSTEM The Prime Technology RTD Temperature System 9219-00-0002 is a three-channel temperature measuring system that utilizes two RTD Temperature Sensor inputs

More information

Control Application. Supplement - ACVMax

Control Application. Supplement - ACVMax prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

1600 Gas Controller. User s Manual. Industrial Scientific Corporation. Version 3.2 September 1, 2006

1600 Gas Controller. User s Manual. Industrial Scientific Corporation. Version 3.2 September 1, 2006 1600 Gas Controller User s Manual Version 3.2 September 1, 2006 Industrial Scientific Corporation 1 INTRODUCTION... 1 1.1 GENERAL OPERATION... 1 1.1.1 Power Up... 1 1.1.2 Viewing Sensors... 2 1.1.3 Acknowledging

More information

Pioneer-R16 Gas Monitor Operator s Manual

Pioneer-R16 Gas Monitor Operator s Manual Pioneer-R16 Gas Monitor Operator s Manual Edition 7/2/97 RKI INSTRUMENTS, INC RKI Instruments, Inc. 33248 Central Ave, Union City, CA 94587 (510) 441-5656 Chapter 1: Description About the Pioneer-R16 Gas

More information

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - TriMax prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

FIRERAY 5000 range USER GUIDE

FIRERAY 5000 range USER GUIDE FIRERAY 5000 range USER GUIDE 0044-003-04 IMPORTANT PLEASE NOTE: The beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal.

More information

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device Safety Instructions Used symbols Important Comments Before starting with installation of the MS 10B Alarm Unit, we recommend you to read the important information beneath. Qualification The installation

More information

Soft Start Series MP700 Solid State, Reduced Voltage

Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s

More information

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual Instruction manual MTL process alarm equipment October 2016 CSM 725B rev 2 MTL RTK 725B Configuration Software Manual SECTION 1 - INTRODUCTION... 5 Basic Requirements... 5 SECTION 2 - SOFTWARE INSTALLATION...

More information

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408 997-060180-5 Installation Instructions / User s Manual TSTAT0406 and TSTAT0408 4 HEAT 2 COOL DUAL FUEL TSTAT0406 & TSTAT0408-4 WIRE CAPABLE THERMOSTAT (NAXA00201DB Daughter Board sold separately) LEFT

More information

ZLM4 OEM Technical Manual

ZLM4 OEM Technical Manual ZLM4 OEM Technical Manual Version 3, June 2014 JVA Technologies Pty Ltd Page 1 of 32 Issue:1/08/2014 10:49:00 AM Contents INTRODUCTION... 4 Scope and Purpose... 4 DRAFT... 4 Features... 5 Limitations...

More information

Fire Command Keypad. XR5 User s Guide

Fire Command Keypad. XR5 User s Guide Fire Command Keypad XR5 User s Guide Silencing an Alarm While the fire alarm horns, strobes, or sirens are sounding use one of the following methods to silence the alarm depending on which type of keypad

More information

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL 6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL USER MANUAL Protec Fire Detection plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0)

More information

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1 Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User

More information

Across-the-Line SERIES MP300 Combined Manual and Automatic

Across-the-Line SERIES MP300 Combined Manual and Automatic Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps

More information

ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling

ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling DataSheet ev 1.12.304/4.0 June 14, 2016 Operating Sequence

More information

Section 9 System Operation

Section 9 System Operation Section 9 System Operation Operation of the control panel is simple. Menus guide you step-by-step through operations. This section of the manual is an overview of the operation menus. Please read this

More information