1 Ref. No.: Version: 1.0 IESNA SUSTAINING MEMBER LCGP Date of issue: Mar. 28, 2016 Total pages: 8 Test report of In Situ Temperature Measurement Rendered to: GLL Shenfubao Industry Park, Bonded Area,Futian District,Shenzhen,China For products: 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Models No.: PL-50W TG-05(3000K) Test Date: Mar. 25, 2016 Test Lab.: LCTECH (Zhongshan) Testing Service Co.,Ltd 2/F.,Technology and Enterprise Development Center, Guangyuan Road, Xiaolan, Zhongshan, Guangdong, China Test Note: Complied by: Reviewed by: Bowen Pang ProjectEngineer Richard Li Technical Manager Mar. 28, 2016 Mar. 28, 2016 The duplication of this report or parts of it and its use for advertising purposes is only allowed with permission of the testing laboratory. This report contains the result of the examination of the product sample submitted by the applicant. A general statement concerning the quality of the products from the series manufacture cannot be derived therefore. This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST, or any agency of the Federal Government.

2 Page 2 of 8 Ref. No.: LCGP , V1.0 Table of Contents 1. General Product Information Standards or methods Equipment list Test conducted and method Ambient Condition Temperature Stabilization Thermocouples Thermocouples contact Test Result Summary Electrical data Temperature data Thermocouple contact photo... 7 Appendix 1 Product Photo... 8

3 1. General 1.1 Product Information Brand Name Page 3of 8 Ref. No.: LCGP , V1.0 GLL Trade Mark - Category Type Indoor Primary Use 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model Number PL-50W TG-05(3000K) Rated Inputs V, 50/60Hz Rated Power 50W RatedLight output 5500lm Declared CCT 3000K Power Supply MPU60D-42 LED Package, Array or Module Model: HL-A-2835DW-S1-08-HR3, manufactured by GuangZhou HongLi Opto-Electronic Co., Ltd Receipt Samples 1 unit Date of Receipt Samples Mar. 16, 2016 Note -

4 Page 4of 8 Ref. No.: LCGP , V Standardsor methods The followingstandards are partly or totallyused or referenced fortest: No. Name ANSI/UL 1598:2008 Luminaires (Secs. 19.7, ) IES LM Measuring Lumen Maintenance of LED Light Sources 1.3 Equipment list Instrument ID Model name Cal. date Next cal. Date AC power supply LC-I-989 APW-120N Power analyzer LC-I-977 WT Multimeter LC-I-972 Fluke 17B Wireless temperature transmitter LC-I-980 DWRF-B J thermocouple LC-I-096 TT-J-30-SLE( m/r) Data acquisition/switch unit LC-I A

5 2. Test conducted and method Page 5 of 8 Ref. No.: LCGP , V Ambient Condition Test was conducted in an ambient temperature of 25 5 C. Ambient temperature variationsabove or below 25 Cwas subtracted from or added to temperatures recorded at pointson the luminaire. The ambient temperaturewasmeasured by a thermocouple which was immersed in 15mlof mineral oil in aglasscontainer. 2.2 Temperature Stabilization Temperatures were measured after they have stabilized when the test has been running for a minimum of 7.5 hours, or the test has been running for a minimum of 3hours and three successive reading taken at 15 minutes intervals are with 1 C of another and are not rising. 2.3 Thermocouples Type Jthermocouple was used for temperaturemeasurement. The thermocouplewas 0.05mm 2 (30AWG), and complied with the requirements specified in ASTM MNL 12 and limits of error specified in NIST ITS 90 and ISA MC Thermocouples contact Thermocouples were in contact with the TMP LED location described in LM-80 test report. In order to gain the maximum temperature, if appropriate, more than one thermocouple were contact in these locations. For details information, please refer to clause 3.3 for the photo of thermocouple contact.

6 3. Test Result Summary 3.1 Electrical data Criteria Item InputVoltage & Frequency Page 6of 8 Ref. No.: LCGP , V1.0 Result V~60Hz Input Current(A) Total Power(W) Power Factor Current on eachled 50mA Off-state Power Temperature data Criteria Item Total operatedperiod Ambient temperature Measured maximum LED Maximum LED(Normalized to 25 C) Result 4.2hours 24.0 C 39.2 C 40.2 C Note: N.A.

7 3.3 Thermocouple contact photo Page 7 of 8 Ref. No.: LCGP , V1.0 Picture 1 Part View Picture 2 Overview

8 Appendix 1 Product Photo Page 8 of 8 Ref. No.: LCGP , V1.0 Picture 1 Picture 2 ****End of test report****

Models: LED-8088M40/LED-8088M40C,LED-8088E40/LED-8088E40C,LED-8088M57 /LED-8088M57C,LED-8088E57/LED-8088E57C

Models: LED-8088M40/LED-8088M40C,LED-8088E40/LED-8088E40C,LED-8088M57 /LED-8088M57C,LED-8088E57/LED-8088E57C IESNA SUSTAINING MEMBER Ref. No.: LCGP15060198 Dateof issue July 22,2015 Version 1.0 Total pages: 10 Test report of In Situ Temperature Measurement And Lumen Maintenance Projection Rendered to: LIGHT EFFICIENT

More information

DRAFT. Models: LED-8085M30, LED-8085M30C; LED-8085M42, LED-8085M42C; LED-8085M57, LED-8085M57C

DRAFT. Models: LED-8085M30, LED-8085M30C; LED-8085M42, LED-8085M42C; LED-8085M57, LED-8085M57C IESNA SUSTAINING MEMBER Test report of In Situ Temperature Measurement And Lumen Maintenance Projection Rendered to: LIGHT EFFICIENT DESIGN, DIV OF TADD LLC 188 S. Northwest Highway Cary, IL60013 For products:

More information

NVLAP LAB CODE In Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: AOK)

NVLAP LAB CODE In Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: AOK) In Situ Temperature Measurement Test Report For AOK LED Light Company Limited (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province,

More information

In Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: ) Outdoor Pole/Arm-Mounted Area and Roadway Luminaires

In Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: ) Outdoor Pole/Arm-Mounted Area and Roadway Luminaires In Situ Temperature Measurement Test Report For AOK LED Light Company Limited (Brand Name: ) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province,

More information

NVLAP LAB CODE In Situ Temperature Measurement Test Report. For SHENZHEN SUNPER OPTO CO.,LTD. (Brand Name: SUNPER)

NVLAP LAB CODE In Situ Temperature Measurement Test Report. For SHENZHEN SUNPER OPTO CO.,LTD. (Brand Name: SUNPER) In Situ Temperature Measurement Test Report For SHENZHEN SUNPER OPTO CO.,LTD (Brand Name: SUNPER) 5/F,BLOK C,SANMIN INDUSTRIAL PARK,SHIYAN STREET, BAO AN DISTRICT,SHENZHEN 518108,GUANGDONG,CHINA High-Bay

More information

NVLAP LAB CODE For. Shen Zhen Green Works Lighting Co., Ltd. Floor 4, Bldg. A, No. 36-8, Yingtai Road,Dalang, Longhua, SHENZHEN,China.

NVLAP LAB CODE For. Shen Zhen Green Works Lighting Co., Ltd. Floor 4, Bldg. A, No. 36-8, Yingtai Road,Dalang, Longhua, SHENZHEN,China. In Situ Temperature Measurement Test Report For Shen Zhen Green Works Lighting Co., Ltd (Brand Name: Green Works Lighting) Floor 4, Bldg. A, No. 36-8, Yingtai Road,Dalang, Longhua, SHENZHEN,China. High-bay

More information

NVLAP LAB CODE ISTMT Test Report. For IROCO AOTOM (HUBEI) PHOTOELECTRICITY CO., LTD

NVLAP LAB CODE ISTMT Test Report. For IROCO AOTOM (HUBEI) PHOTOELECTRICITY CO., LTD ISTMT Test Report For IROCO AOTOM (HUBEI) PHOTOELECTRICITY CO., LTD Aotom LED Industrial Park, Qingzhuanzhu Road 268, Huanggang, Hubei, China LED Panel Light Model name(s): 22AP3235A (CLC/WLC FPL22-835-32W-130LW-UNV-DIM1-WH)

More information

Technical-Report for SL Lamp 5 W

Technical-Report for SL Lamp 5 W Technical-Report for SL Lamp 5 W Technical Report No. 68.184.17.478.01 Dated 2017-06-27 Client: Manufacturing place: Name: PHOCOS China Ltd. Address: 3F 1st Bldg. 4A Chang Yi Road, 266021, Qingdao, PEOPLE'S

More information

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 FOR THE SCOPE OF. ACCREDITATION UNDER NVLAP LAB CODE 100402-0.. Project No. G101537614 Date: April 8, 2014 REPORT NO. G101537614CRT-005 TEST OF ONE LED

More information

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 FOR THE SCOPE OF ACCREDITATION UNDER NVLAP LAB CODE 100402-0. Project No. G101030158 Date: February 26, 2013 REPORT NO. 101030158CRT-001 TEST OF ONE LED

More information

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727 REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727 Project No. G101464624CRT-001 Date: January 17, 2104 INTERTEK REPORT NO. G101464624CRT-001 DIALIGHT REPORT NO. L13029 TEST OF ONE LSA ATEX ZONE

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 REPORT 58 COMMERCENTRE DRIVE, LAKE FOREST, CA 963 Project No. G67677 Date: June 6, 4 REPORT NO. 67677LAX- TEST OF ONE FULL ON AT 9 BEAM ANGLE MODEL NO. RAZOR Q ZOOM RENDERED TO ELATION PROFESSIONAL 6 S.

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 FOR THE SCOPE OF ACCREDITATION UNDER A2LA TO ISO/IEC 17025:2005. REPORT 25800 COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 Project No. G101786356 Date: August 19, 2014 REPORT NO. 101786356LAX-001 TEST OF

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 REPORT 58 COMMERCENTRE DRIVE, LAKE FOREST, CA 963 Project No. G119188 Date: March 13, REPORT NO. 119188LAX-4 TEST OF ONE LED WASH MODEL NO. COLOUR CHORUS 4 RENDERED TO ELATION PROFESSIONAL 61 S. EASTERN

More information

Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight

Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight Directional Luminaire Test Report For ELEC-TECH INTERNATIONAL CO LTD No. 1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R.China 519085 LED Downlight Model name(s):

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 REPORT 58 COMMERCENTRE DRIVE, LAKE FOREST, CA 93 Project No. G138456 Date: April, 16 REPORT NO. 138456LA-51 TEST OF ONE CYCLORAMA WALL WASH LUMINAIRE MODEL NO. TVL CYC RGBW RENDERED TO ACCLAIM LIGHTING

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 REPORT 58 COMMERCENTRE DRIVE, LAKE FOREST, CA 96 Project No. G85 Date: April 6, 5 REPORT NO. 85LAX- TEST OF ONE WALL BRACKET JELLY JAR MODEL NO. H-CGU--B LED MODEL NO. BRIDGELUX BXRC-E-C-X DRIVER MODEL

More information

ENERGY STAR Program Requirements

ENERGY STAR Program Requirements Report No.: LCZP17050329 Version: 1.0 Date Of Issue: Jun. 17, 2017 Total Pages: 17 Test Report of ENERGY STAR Program Requirements for Luminaires V2.0- Inseparable SSL Luminaires Applicant: ELEC-TECH INTERNATIONAL

More information

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 . REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102671575 Date: July 27, 2016 REPORT NO. 102671575CHI-002 TEST OF ONE ROADWAY/AREA LUMINAIRE MODEL NO. APL-NW200 LED MODEL NO. SAMSUNG

More information

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 . REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102748333 Date: December 20, 2016 REPORT NO. 102748333CHI-015 TEST OF ONE T8 LED TUBE MODEL NO. T8-NW18F LED MODEL NO. HONGLI OPTO-ELECTRONIC

More information

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 . REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102748333 Date: February 21, 2017 REPORT NO. 102748333CHI-024 TEST OF ONE LED WALL PACK MODEL NO. WPFC-CW70 LED MODEL NO. PHILIPS

More information

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 . REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102748333 Date: January 24, 2017 REPORT NO. 102748333CHI-018 TEST OF ONE LED EPLOSION PROOF LIGHT MODEL NO. EPL-NW200 LED MODEL NO.

More information

ETL Testing Laboratories, Inc.

ETL Testing Laboratories, Inc. Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318 952-448-7377 FAX:952-448-2613 Fire Retardant HOT LINE 1-800-913-9385 e-mail: info@fireretardantsinc.com

More information

REPORT NUMBER: MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015

REPORT NUMBER: MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015 REPORT NUMBER: 101960325MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015 EVALUATION CENTER Intertek Testing Services NA Inc. 8431 Murphy Drive Middleton, WI 53562 TEST REPORT

More information

RF TEST REPORT. ZTE Corporation SRQ-VFD510 ZTE LTE/WCDMA/GSM GPRS RXC RF07

RF TEST REPORT. ZTE Corporation SRQ-VFD510 ZTE LTE/WCDMA/GSM GPRS RXC RF07 RF TEST REPORT Applicant FCC ID Brand Product ZTE Corporation SRQ-VFD510 ZTE LTE/WCDMA/GSM GPRS Model VFD 511 Multi-Mode Digital Mobile Phone Report No. RXC1703-0087RF07 Issue Date May 24,2017 TA Technology

More information

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. FCC MPE REPORT

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. FCC MPE REPORT No. 588 West Jindu Road, Songjiang District, Shanghai, China Telephone: +86 (0) 21 61915666 Fax: +86 (0) 21 61915678 ee.shanghai@sgs.com Page 1 of 8 1 Cover Page Application No.: Applicant: FCC MPE REPORT

More information

Familiarization with the Training System

Familiarization with the Training System Exercise 1-1 Familiarization with the Training System EXERCISE OBJECTIVE In this exercise, you will familiarize yourself with the components of the training system that are used for the measurement and

More information

Refrigerating Appliance ErP Test Report

Refrigerating Appliance ErP Test Report Report Number Test Laboratory Name / Address Applicant Name / Address Manufacturing Name / Address Product Brand Name Description Model(s) (if applicable) Model Similarity Ratings Date of receipt of sample(s)

More information

EN 60529:1991+A1:2000+A2:2013 Measurement and Test Report

EN 60529:1991+A1:2000+A2:2013 Measurement and Test Report EN 60529:1991+A1:2000+A2:2013 Measurement and Test Report For Fujian Juston Electronic Equipment Co.,Ltd No.115,117,119,Yuantai 3rd Road,Jiangnan Hi-tech Park,Licheng District, Quanzhou,Fujian,China 362000

More information

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture PRODUCT SPECIFICATIONS Frame-in Kit HOUSING: Fire and sound-rated housing. Up to 20 minute fire rated L500 (floor-ceiling) & P500 (roof-ceiling) design. Die formed #24 gauge galvanized steel construction.

More information

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight DRD5S & SurfaceFrame Alt/EM Project: Product Code: Type: Date: Spec Sheet V- 11.15.18 Maintains all the standard SurfaceFrame ratings Offers enhanced dimming protocol compatibility including Lutron Hi-Lume

More information

Lamp Circuit Power Test Report

Lamp Circuit Power Test Report Report : 3192007.50P Lamp Circuit Power Report To : GE (Lighting) Co., Ltd. Tel : -- Building E, Longcheer Park,.29, Jinye 1 st Fax : -- Road, 710065, Xi an, China Attn : James Guo Supplier : Sichuan Hongrui

More information

MPE TEST REPORT 2APNR-GW631Q R1805A0254-M1V1

MPE TEST REPORT 2APNR-GW631Q R1805A0254-M1V1 MPE TEST REPORT Applicant FCC ID Product Model Report No. Gosuncn Technology Group Co.,Ltd. 2APNR-GW631Q LTE CPE WF831, WF831+, WF831A, GW631 R1805A0254-M1V1 Issue Date June 6, 2018 TA Technology (Shanghai)

More information

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13 Test Report No. AJHG1501000530FB Date: FEB.17, 2015 Page 1 of 13 ZHEJIANG TERASUN AIR DUCT CO., LTD MAREN VILLAGE, CHONGREN INDUSTRIAL ZONE, CHONGREN TOWN, SHENGZHOU CITY, ZHEJIANG PROVINCE, CHINA The

More information

1.0 INTRODUCTION 2.0 CLASSIFICATION CRITERIA

1.0 INTRODUCTION 2.0 CLASSIFICATION CRITERIA 1.0 INTRODUCTION This report presents the results of an investigation of the external fire resistance characteristics of the VELUX FCM Deck Mounted Skylight roof covering system in general accordance with

More information

DRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light

DRD5S & SurfaceFrame Alt/EM 18 Linear Surface Mount LED Area Light DRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light Project: Product Code: Type: Date: Spec Sheet V- 04.15.19 Maintains all the standard SurfaceFrame ratings Offers enhanced dimming protocol

More information

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date: Energy Report EDR-5391 Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49 Qualification Testing of Nuclear High Voltage Splice (NHVS) Enclosures: Report Number: Date: EDR-5391

More information

Kräftigled Catalogue 2016

Kräftigled Catalogue 2016 Kräftigled Catalogue 2016 Welcome! KraftigLED is an Irish owned and run bespoke LED design and manufacturing company. Set up in 2015 and based in Ireland and China, KraftigLED produce the world s most

More information

Certification Supplement Manual

Certification Supplement Manual PROCESS ANALYSERS SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 2 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EC DECLARATION OF CONFORMITY

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2010-12-01 Page 1 of 16 Report Reference # E252373-A31-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2014-10-14 (Information

More information

FCC COMPLIANCE REPORT. SHENZHEN STARWELL TECHNOLOGY CO., Ltd. AC/DC ADAPTER

FCC COMPLIANCE REPORT. SHENZHEN STARWELL TECHNOLOGY CO., Ltd. AC/DC ADAPTER FCC COMPLIANCE REPORT SHENZHEN STARWELL TECHNOLOGY CO., Ltd. for AC/DC ADAPTER Model Number : SMS-01XXXYYY-S06 XXX Stand for output voltage; YYY Stand for output current Prepared for : SHENZHEN STARWELL

More information

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer TEST REPORT IEC 61000-4-2-2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test Report Reference No....: SQE13090002 R/C: 60520

More information

The product and any acceptable variation thereto is specified in the Annex to this certificate and the documents therein referred to.

The product and any acceptable variation thereto is specified in the Annex to this certificate and the documents therein referred to. CERTIFICATE Issued to Applicant MEAN WELL Enterprises Co., Ltd. No.28, Wuquan 3rd Road, Wugu District 248 New Taipei City, Taiwan Product Trade name(s) Type(s)/model(s) Licensee MEAN WELL Enterprises Co.,

More information

ULT Freezer Performance Testing Emerson Design Services Network Project #

ULT Freezer Performance Testing Emerson Design Services Network Project # ULT Freezer Performance Testing Emerson Design Services Network Project # 111686 Design Services Network Test Performed by: Dan Rice & Don Wenrich Design Services Network Report Prepared by: Robert V.

More information

SECTION INTERIOR LIGHTING

SECTION INTERIOR LIGHTING SECTION 26 51 00 INTERIOR LIGHTING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Cosmetology Lab Redesign

Cosmetology Lab Redesign Cosmetology Lab Redesign Shane A. Semple - 25-4/5/2005 Design Concept: The Cosmetology Lab is a space that will be used for teaching students the trades of cutting hair, applying make-up, and doing manicures.

More information

Refrigerating Appliance DOE Test Report

Refrigerating Appliance DOE Test Report Report Number Test Laboratory Name / Address Applicant Name / Address Manufacturing Name / Address Product Brand Name Description Model(s) (if applicable) Model Similarity Ratings Refrigerating Appliance

More information

Surface Materials. Surface Material Reflectance. Acoustic Ceiling 80% Tile. Painted Gypsum 75% Wall Board. Vinyl Composition 32% Tile

Surface Materials. Surface Material Reflectance. Acoustic Ceiling 80% Tile. Painted Gypsum 75% Wall Board. Vinyl Composition 32% Tile Genetics Laboratory Space Description The Genetics Laboratory is located on the second floor of the laboratory building. The main functions of this space are as a learning and research area. There is a

More information

Safety Certification of Solid-State Lighting Products. September 23, 2009 Todd Straka Director - Lighting Services

Safety Certification of Solid-State Lighting Products. September 23, 2009 Todd Straka Director - Lighting Services Safety Certification of Solid-State Lighting Products September 23, 2009 Todd Straka Director - Lighting Services Discussion Points for Today s Webinar Product Safety Certification Process Overview Key

More information

LHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy.

LHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy. Technical Specifications Description The High Bay luminaire delivers the illumination performance to replace up to a 400W HID fixture one-for-one. Lumecon s unique High Bay design makes this fixture an

More information

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance Page 1 of 157 Report No.: E309264-D1009-1-CB CB - IEC REPORT: Test Report issued under the responsibility of: IEC 60601-1 Medical electrical equipment Part 1: General requirements for basic safety and

More information

CE EMC Test Report EN :2015 EN :2017. Folder with powerbank ZKS E. Lieber Ouyang (Engineer) Lahm Peng (Manager)

CE EMC Test Report EN :2015 EN :2017. Folder with powerbank ZKS E. Lieber Ouyang (Engineer) Lahm Peng (Manager) CE EMC Test Report Test Standard(s): Applicant: Product Name: EN 55032 :2015 EN 55035 :2017 Goya Importacionesy Distribuciones SL B50154293 Folder with powerbank Model: 606090 Report No.: ZKS180800212E

More information

File E Project 08ME October 7, 2008 REPORT. UNLISTED COMPONENT - Attachment Plugs, Fuseless. For Use Only In

File E Project 08ME October 7, 2008 REPORT. UNLISTED COMPONENT - Attachment Plugs, Fuseless. For Use Only In File E170507 Project 08ME09223 October 7, 2008 REPORT ON UNLISTED COMPONENT - Attachment Plugs, Fuseless For Use Only In APPLICANT'S CLASSIFIED, LISTED OR RECOGNIZED PRODUCTS, SYSTEMS OR COMPONENTS Globtek

More information

GUANGDONG XINYU TECHNOLOGY INDUSTRIAL CO., LTD

GUANGDONG XINYU TECHNOLOGY INDUSTRIAL CO., LTD 中国认可国际互认检测 TESTING CNAS L1744 GUANGDONG XINYU TECHNOLOGY INDUSTRIAL CO., LTD Date Received: Jun 20, 2016 Page 1 of 5 GUANGDONG XINYU TECHNOLOGY INDUSTRIAL CO., LTD LAIMEI INDUSTRIAL ZONE, CHENGHAI DISTRICT,

More information

Product Compliance Andy Guest

Product Compliance Andy Guest Product Compliance Andy Guest EDA Forum November 2015 www.thelia.org.uk What do we mean by compliant in lighting? How do we know products are compliant? Its CE Marked That means its OK doesn t it? What

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: Test Report issued under the responsibility of: NCB TÜ V SÜ D PSB Pte Ltd 1 Science Park Drive, Singapore 118221 TEST REPORT IEC 61347-2-13 Part 2: Particular requirements: Section Thirteen d.c. or a.c.

More information

Application for FCC Certificate On Behalf of. TTE Technology, Inc. LCD TV or LED TV. Model Number: 55R80 FCC ID:W8U55R80

Application for FCC Certificate On Behalf of. TTE Technology, Inc. LCD TV or LED TV. Model Number: 55R80 FCC ID:W8U55R80 Application for FCC Certificate On Behalf of TTE Technology, Inc. LCD TV or LED TV Model Number: 55R80 FCC ID:W8U55R80 Prepared for : TTE Technology, Inc. Address : 2455 Anselmo Drive Suite 101 Corona

More information

Listing Constructional Data Report (CDR)

Listing Constructional Data Report (CDR) Listing Constructional Data Report (CDR) 1.0 Reference and Address Report Number HZ12070036-0 Original Portable Electric Luminaires ANSI/UL 153(12th Ed, rev. March 24, 21) Standard(s) Portable Luminaires

More information

DESCRIPTION. SB-C LED Flat Panel Series. Page:1 of 6

DESCRIPTION. SB-C LED Flat Panel Series. Page:1 of 6 Page:1 of 6 DESCRIPTION The SB-C series LED Luminaries, utilizing an aluminium frame, 0.31" ultrathin side emitting design and high transmittance light guide plate, provides uniform light distribution

More information

Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015

Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015 Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015 Version 2.0 January, 2015 Prepared for Pacific Gas and Electric Company San Francisco, California Prepared by Energy Solutions

More information

Test Report. Test Requested : Test for compliance with clauses 8 and 9 of IEC : 1993+A1+A2. Page 1 of 6

Test Report. Test Requested : Test for compliance with clauses 8 and 9 of IEC : 1993+A1+A2. Page 1 of 6 Applicant: Y. Lin Electronics Co., Ltd. No. 3 Xinguang Road, Jinhe The third Industrial Zone, Zhangmutou Town, Dongguan,. Guangdong, China. Number: Date: 11 Feb 2015 15020100HKG-001 Sample Description

More information

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product PERFORMANCE TEST REPORT Rendered to: EVERBLOCK SYSTEMS, LLC PRODUCT: Modular Block Product Report No.: G1320.01-106-31 Report Date: 08/04/16 Test Record Retention Date: 07/29/20 130 Derry Court York, PA

More information

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series) Albeo LED Luminaire Heavy Industrial Low Bay Lighting (ALR1 - Series) Product Features The Albeo ALR1-series LED luminaire is an energy-efficient, low maintenance alternative to traditional fluorescent

More information

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance Test Report issued under the responsibility of: SGS- CSTC TEST REORT Safety of household and similar electrical appliances art 2: articular requirements for massage appliance Report Reference No....: GZES100800181503

More information

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier Page 1 of 27 Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier Test Sponsor Saveguard (UK) Limited Warrington Fire Research Centre Ltd.,

More information

Project Name. Date. Cat. Number. Type

Project Name. Date. Cat. Number. Type Linear Series 2.0 LED linear luminaires and retrofit linear kits The Linear Series delivers ultra-long life and high efficacy. Fixtures can be installed independently or joined together for continuous-run

More information

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol. Process Analysis Systems Chem Energy Pharm Food Water Stratos Eco 2405 CondI Inductive Conductivity Measurement Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement

More information

FIRE RETARDANT ARCHITECTURAL WOOD COATING FIRE SHIELD FS020 FIRE-SHIELD SEALER. FS021 FIRE-SHIELD TOP COAT Available in different gloss

FIRE RETARDANT ARCHITECTURAL WOOD COATING FIRE SHIELD FS020 FIRE-SHIELD SEALER. FS021 FIRE-SHIELD TOP COAT Available in different gloss FIRE RETARDANT ARCHITECTURAL WOOD COATING ASTM E84 CLASS A FIRE SHIELD FS020 FIRE-SHIELD SEALER FS021 FIRE-SHIELD TOP COAT Available in different gloss www.duro-lak.com Easy to apply Water base sealer

More information

MEASUREMENT AND TEST REPORT

MEASUREMENT AND TEST REPORT MEASUREMENT AND TEST REPORT For United GULF GATE Co. Aladel Tower,F21,Fahad Al Salem St., State of KUWAIT Model: XT-60 IP-PBX This Report Concerns: Original Report Equipment Type: IP PBX Test Engineer:

More information

Test Report. Appliance EMF Testing

Test Report. Appliance EMF Testing Project: 11014506A Date: November 6, 2015 Model: 120V_WWF13NW Test Report On Appliance EMF Testing Copyright 2005 UL LLC UL LLC authorizes the above-named company to reproduce this Report provided it is

More information

2016 Title 24, Part 6 Reference Joint Appendices JA8 & JA10 Residential Lighting Test, Certify, & Comply

2016 Title 24, Part 6 Reference Joint Appendices JA8 & JA10 Residential Lighting Test, Certify, & Comply 2016 Title 24, Part 6 Reference Joint Appendices JA8 & JA10 Residential Lighting Test, Certify, & Comply California s High Efficacy Lighting Requirements for Residential Applications Kelly Cunningham Pacific

More information

Issued to: Videl S.r.l. Località Ponti di Pievescola Casole d Elsa (SI)

Issued to: Videl S.r.l. Località Ponti di Pievescola Casole d Elsa (SI) TEST REPORT N. TRP_297_12 CETACE Laboratory in collaboration with Electronic and Telecommunication Department of the University of Florence Title: IP23 test Reports consists of no. 16 pages Result: Pass

More information

Test Report. Test Requested : Test for compliance with clauses 8 and 9 of IEC : 1993+A1+A2. Page 1 of 6

Test Report. Test Requested : Test for compliance with clauses 8 and 9 of IEC : 1993+A1+A2. Page 1 of 6 Applicant: Y. Lin Electronics Co., Ltd. No. 3 Xinguang Road, Jinhe The third Industrial Zone, Zhangmutou Town, Dongguan,. Guangdong, China. Number: Date: 11 Feb 2015 15020097HKG-001 Sample Description

More information

Environment Test Report

Environment Test Report Environment Test Report Product Name: Product Model: Product Type: Power System TP48200A TP48200A-H15A3 TP48200A-H15A5 TP48200A-D15A1 Report Number: SYBH(H) 346052012 Reliability Laboratory of Huawei Technologies

More information

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination THE HIGH PERFORMANCE LED Fixture Series for General, Direct and Indirect Illumination KEY FEATURES INCLUDE: Advanced Thermal Management Industry Leading Deep Fin Heat Sinks with Aircraft Grade Aluminum

More information

Operating Manual MS220DA

Operating Manual MS220DA ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße 13, D 74523 Schwäbisch Hall + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA Mains Monitoring Digital Panel Meters MINIPAN

More information

In accordance with the Radio Waves Act Chapter 58 Article 8(3), the document below is a

In accordance with the Radio Waves Act Chapter 58 Article 8(3), the document below is a Korea Communications Commission Notification 2011-37 In accordance with the Radio Waves Act Chapter 58 Article 8(3), the document below is a guideline for all broadcasting and telecommunications equipment

More information

Certification Supplement Manual

Certification Supplement Manual SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 5 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EU DECLARATION OF CONFORMITY 3 EUROPEAN

More information

BURNING BRAND PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR (Acrylic Dome) VELUX SUN TUNNEL

BURNING BRAND PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR (Acrylic Dome) VELUX SUN TUNNEL BURNING BRAND PERFORMANCE TEST REPORT Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR 022 0000 (Acrylic Dome) VELUX SUN TUNNEL ACCESSORY PRODUCTS: Tubular Skylight with ZTA 022 000090 9" Turrets

More information

SECTION Fluorescent Dissolved Oxygen Measuring System

SECTION Fluorescent Dissolved Oxygen Measuring System SECTION 40 75 43 Fluorescent Dissolved Oxygen Measuring System PART 1 General 1.01 SUMMARY A. Requirements for a high-performance, digital fluorescence sensor for measurement of dissolved oxygen in liquid.

More information

IMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc.

IMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc. CEMS Operating Manual IMR USA S/N: Sample IMR 5000 IMR 400 IMR 400 IMR 5000 Measure MESURE PURGE Purge CALIBRATE Calibrate OFF OFF RESET Measure ON ON Calibrate RESET PUMP Gas Dryer Inside PUMP Sensors

More information

Report Nr

Report Nr Report Nr. 07207334856 Applicant: Fluid Components Ltd. 1755 La Costa Meadows Drive San Marcos, CA 92069 USA Device under test: FLT 93 - Sensor System Testing body: TÜV NORD CERT GmbH Safety Related Services

More information

LHBXD LED Linear High Bay

LHBXD LED Linear High Bay Catalog # : Project : Prepared By : Date : LHBXD The LHBXD is the perfect solution for a wide variety of applications and mounting heights. It s competitive pricing, multiple lumen packages, and high ambient

More information

F, T, L and W Ratings - What are the Code & Testing Requirements?

F, T, L and W Ratings - What are the Code & Testing Requirements? F, T, L and W Ratings - What are the Code & Testing Requirements? Rich Walke Underwriters Laboratories Inc. April 27, 2010 Copyright 1995-2007 Underwriters Laboratories Inc. All rights reserved. No portion

More information

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1 REPORT NUMBER: 101145164COQ-005 ORIGINAL ISSUE DATE: April 25, 2013 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 RENDERED TO udecor Inc.

More information

Technical Report No. CPSA Rev. 00 Dated Test according to the test specification Evaluation and categorization

Technical Report No. CPSA Rev. 00 Dated Test according to the test specification Evaluation and categorization Client: IZEN Co., Ltd. 242, Aegibong-ro, Wolgot-myeon Gimpo-si, Gyeonggi-do 415-873 REPUBLIC OF KOREA Contact Person: ISA AC Kim Tel.: +82-31-999-7300, 070-4705-1878 Fax.: +82-31-997-3147 Manufacturing

More information

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance Page 1 of 170 Report No.: E309264-D1021-1/A1/C0-UL IEC REPORT: Test Report issued under the responsibility of: IEC 60601-1 Medical electrical equipment Part 1: General requirements for basic safety and

More information

Lighting Measurement Solutions

Lighting Measurement Solutions Lighting Measurement Solutions Continuous improvement in lighting demands ever better metrology tools. More and more businesses rely on modern measurement practices to be competitive and outstanding. We

More information

Electric radiator tests

Electric radiator tests Electric radiator tests Carried out for Haverland By P Stonard 16 July 2010 Electric radiator tests Carried out for: Haverland Avda San Martin De Valdeigiesias Km-2,200 Alcorcon MADRID 28925 Spain Contract:

More information

EU-Type Examination Certificate

EU-Type Examination Certificate EU-Type Examination Certificate Measuring Instrument Directive Certificate number: 0200-MID-02784 Issued by FORCE Certification A/S, Denmark EU-notified body number 0200 In accordance with the Directive

More information

Copy of marking plate:

Copy of marking plate: DOGGUA EMTEK CO., LTD. REORT O.: ED140115093S Copy of marking plate: Summery of test: 1. The AC/DC ADATER complied with level V (refer to International Efficiency Marking rotocol ). 2. The EUT was tested

More information

USER APPROVAL OF SAFETY INSTRUMENTED SYSTEM DEVICES

USER APPROVAL OF SAFETY INSTRUMENTED SYSTEM DEVICES USER APPROVAL OF SAFETY INSTRUMENTED SYSTEM DEVICES Angela E. Summers, Ph.D., P.E, President Susan Wiley, Senior Consultant SIS-TECH Solutions, LP Process Plant Safety Symposium, 2006 Spring National Meeting,

More information

Alliance 4 - ALI4 LED 4 Linear High Bay

Alliance 4 - ALI4 LED 4 Linear High Bay Catalog # : Project : Prepared By : Date : Alliance 4 - ALI4 The new Alliance indoor LED high bay was designed to provide flexibility on any project. For use with applications ranging from school gymnasiums

More information

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy REPORT NUMBER: 100900037COQ-002 ORIGINAL ISSUE DATE: October 10, 2012 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, BC V3K 7C1 RENDERED TO Laminam S.P.A.

More information

CLASSIFICATION Constructional Data Report (CDR)

CLASSIFICATION Constructional Data Report (CDR) CLASSIFICATION Constructional Data Report (CDR) 1.0 Reference and Address Report Number 100358381SAT-001 Original Standard(s) Fire Test for Heat and Visible Smoke Release for Discrete Products and Their

More information

ENERGY STAR Program Requirements for Residential Light Fixtures. Eligibility Criteria Version 4.2. Table of Contents

ENERGY STAR Program Requirements for Residential Light Fixtures. Eligibility Criteria Version 4.2. Table of Contents ENERGY STAR Program Requirements for Residential Light Fixtures Eligibility Criteria Version 4.2 Table of Contents Section 1: Definitions II Section 2: Qualifying Products V Section 3: Energy Efficiency

More information

Modules and Accessories. Table of Contents. Theta Optical Tensiometer. I - Mandatory modules 2. II - Accessories 4

Modules and Accessories. Table of Contents. Theta Optical Tensiometer. I - Mandatory modules 2. II - Accessories 4 Theta Optical Tensiometer Modules and Accessories Theta optical tensiometer is modular: you can choose exactly the features that you require for your studies. The minimun setup requires one choice from

More information

Zircomat Oxygen Analyzers

Zircomat Oxygen Analyzers Zircomat Oxygen Analyzers Finally Hassle Free Stack Gas Oxygen Measurement Many of the top fortune 500 companies have already discovered that installing a ZIRCOMAT Oxygen analyzer is the smart way to measure

More information

Fast. Precise. Versatile. UL Lighting Sciences

Fast. Precise. Versatile. UL Lighting Sciences Fast. Precise. Versatile. UL Lighting Sciences As the world turns to LED and SSL technology as a primary source of electric light, UL Lighting Sciences continues to build upon our industry-leading technical

More information

AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING AND TESTING REQUIREMENTS FOR LOW CAPACITY WINDOW TYPE AND SINGLE-SPLIT

AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING AND TESTING REQUIREMENTS FOR LOW CAPACITY WINDOW TYPE AND SINGLE-SPLIT SAUDI ARABIAN STANDARD SASO 2663/2017 والجودة الھيئة السعودية للمواصفات والمقاييس Saudi Standards, Metrology and Quality Org (SASO) SASO 2663:2017 (Draft) AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING

More information