FIRE EXTINGUISHER. Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley Extinguishers

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "FIRE EXTINGUISHER. Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley Extinguishers"

Transcription

1 FIRE EXTINGUISHER Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley U.A.E K.S.A

2 FIRE EXTINGUISHER Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley Extinguishers

3 INDEX NTEICO FIRE EXTINGUISHER CAR/ HOME MINI FIRE EXTINGUISHERS 04 DRY POWDER FIRE EXTINGUISHERS AUTOMATIC POWDER CO2 FIRE EXTINGUISHERS 09 FOAM/WATER FIRE EXTINGUISHERS 10 AUTOMATIC FOAM UL APPROVED FIRE EXTINGUISHERS 13 WET CHEMICAL EXTINGUISHERS 14 TROLLEY FIRE EXTINGUISHERS 15

4 CAR/HOME MINI FIRE EXTINGUISHERS Colorful & Powerful Flame Fighter: An elegant extinguisher! 1. Color: Black, Silver, Blue, Red 2. Cylinder Size Height: 290mm Diameter: 66mm 3. Base coat color: White 4. Agent: ABC (Ammonium Phosphate Salt) Powder 50% 5. Expellant: Nitrogen 6. Cylinder Material: Aluminium 7. Valid Time: 4years Fire Stop Foam Fire Extinguishers 1. Applications : Class A fires: burning paper, wood, fiber, textiles, plastics etc. Class B 1 fires: gasoline, kerosene, solvents etc. 2. Size: 400ml, 650ml, 1000ml 3. Advantage: spray longer, harmless, easy to use The agents are non flammable, non irritant, and free of air pollutants. 4. Fast Delivery 04

5 DRY POWDER FIRE EXTINGUISHERS Portable dry powder fire extinguisher is made up of ABC dry power, which is applied to extinguish solid materials, inflammable liquids, combustible gases, organic solvents and voltage under the 5KV primary surface of the fire of the electrical equipment. NT-FE-P-5 NT-FE-P-4 NT-FE-P-2 NT-FE-P-1 Technical Data Model No. Capacity (kg) Weight (kg) Diameter Cylinder Length Working Pressure (Bar) Test Pressure (Bar) Wall Thickness Fire Rating NT-FE-P-1 1 Kg 1±5% A21BC NT-FE-P-2 2 Kg 2±3% A34BC NT-FE-P-4 4 Kg 4±2% A70BC NT-FE-P-5 5 Kg 5±2% A113BC 05

6 DRY POWDER FIRE EXTINGUISHERS Portable dry powder fire extinguisher is made up of ABC dry power, which is applied to extinguish solid materials, inflammable liquids, combustible gases, organic solvents and voltage under the 5KV primary surface of the fire of the electrical equipment. NT-FE-P-12 NT-FE-P-10 NT-FE-P-8 NT-FE-P-6 Technical Data Model No. Capacity (kg) Weight (kg) Diameter Cylinder Length Working Pressure (Bar) Test Pressure (Bar) Wall Thickness Fire Rating NT-FE-P-6 6 Kg 6±5% A113BC NT-FE-P-8 8 Kg 8±3% A144BC NT-FE-P Kg 10±2% A183BC NT-FE-P Kg 12±2% A233BC 06

7 AUTOMATIC POWDER Automatic ABC DRY Chemical Extinguisher NTEICO provides highly effective AUTOMATIC ABC DRY CHEMICAL POWDER EXTINGUISHER. It is suitable for most FIRE CLASSES. The extinguishers body is constructed from COLD Rolled Steel (CRS), which is then fabricated by Automatic Metal Insert Gas (MIG) welding process. Each extinguisher body is subjected to Hydrostatic Pressure in order to assure the safety of the end user. Then, the external surface of the body is Shoot Blasted to improve paint adhesion. To give hard wearing, corrosion resistance and paint adhesion, as well as a glossy finish, each extinguisher is Electro-statically Painted using a POLYESTER RESIN, before being baked in the oven. The Dry Chemical Powder is capable of dealing with class A fires involving carbonaceous materials like wood, paper etc. It also deal with class B fires involving flammable gasses and flammable liquids. It also can be applied for Electrical Fires. Other Features of this Range of Extinguisher are: Supplied with a sprinkler type valve with chrome-plated brass body equipped with a standard response glass bulb sensing element contained in a glass bulb & color coded for operation temperature at 68 degree C, (155 F ) so all external valve parts are protected against corrosion. Supplied complete with a dial pressure indicator, a spring operated safety relief valve, and a recharge port. Supplied complete with a ceiling-bracket suitable for vertical mounting. Simple to maintain and Re-fillable. 07

8 AUTOMATIC POWDER Automatic ABC DRY Chemical Extinguisher Technical Data Specifications NT-APE-10B NT-APE-6 NT-APE-10 Nominal Capacity Kg Lbs Extinguishing Agent DCP-ABC DCP-ABC DCP-ABC Shell Material CRS CRS CRS Average Gross Weight Kg Lbs Minimum Discharge Time Sec Average Height mm inches Shell Diameter mm inches Ave.Radius of Coverage m ft m Height Shell Color Red Red Red Electrical Non-Conductivity up to 1KV (1000 Volts) OK OK OK Upper o C Operating Temperature Range o F Lower o C Range o F Operating Pressure bar

9 CO2 FIRE EXTINGUISHERS The Co2 fire extinguisher is beautiful, sealed well, open flexible, safe, highly efficient for dealing with fires, has a wide range of use & does not pollute the environment. Applicable for electrical equipment, some kind of cars gas stations, libraries, and other public areas. NT-CO-2 NT-CO-3 NT-CO-10B NT-CO-7 NT-CO-9 Technical Data Model No. Capacity (kg) Diameter Cylinder Length Working Pressure (Bar) Test Pressure (Bar) Wall Thickness Material Volume (L) NT-CO CrMo4 3 NT-CO CrMo4 4.5 NT-CO-10B CrMo NT-CO Mn2v 10.5 NT-CO Mn2v

10 FOAM/WATER FIRE EXTINGUISHERS Technical Data Model No. NT-F-6 NT-F-9 Capacity (L) 6L 9L Material of Cylinder Inner Painting (Carbon Steel / Stainless Steel) Inner Painting (Carbon Steel / Stainless Steel) Diameter Cylinder Length Work Pressure (Bar) Test Pressure (Bar) Wall Thickness

11 AUTOMATIC FOAM Automatic Foam (AFFF) Extinguishers NTEICO provides highly effective stored pressure portable Automatic Foam Extinguishers. The Extinguisher agent is Aqueous Film Foaming Foam (AFFF) These EXTINGUISHERS can afford extinguishment of both Class A & B fires. The extinguisher body is constructed from COLD Rolled Steel (CRS), which is then fabricated through the Automatic Metal Insert Gas (MIG) welding process. Each extinguisher body is subjected to Hydrostatic Pressure in order to assure the safety of its end user. Then, the internal surface of the body is thoroughly coated with PPA Coating Powder to ensure both optimal electrical and corrosive resistivity, before the external surface of the body is Shoot Blasted to improve paint adhesion. To give hard wearing, as well as a glossy finish, each extinguisher is Electro-statically Painted, using a POLYESTER RESIN, before being baked in the oven. Other Features of this Range of Extinguisher are: Supplied with a sprinkler type valve with chrome-plated brass body that is equipped with a standard response sensing element contained in a glass bulb and color coded for operation temperature at 68 degree C, (155 F ) so all external valve parts are protected against corrosion. Supplied complete with a dial pressure indicator, a spring operated safety relief valve and recharge port. Supplied complete with a ceiling-bracket suitable for vertical mounting. Easy to use, simple to maintain and re-fillable. 11

12 AUTOMATIC FOAM Automatic Foam (AFFF) Extinguishers Technical Data Specifications NT-AFE-4.5 NT-AFE-6 NT-AFE-10 NT-AFE-12 Nominal Capacity L gal Extinguishing Agent AFFF AFFF AFFF AFFF Shell Material CRS CRS CRS CRS Average Gross Weight Kg Lbs Minimum Discharge TIme Sec Average Height mm inches Shell Diameter mm inches Ave.Radius of Coverage m ft m Height Shell Color Red Red Red Red Electrical Non-Conductivity up to 1KV (1000 Volts) OK OK OK OK Upper o C Operating Temperature Range o F Lower o C Range o F Operating Pressure bar

13 UL APPROVED FIRE EXTINGUISHERS Three Sizes: 2.5Lbs, 5Lbs, 10Lbs Standard: UL Standard ABC Fire Extinguishers utilize a specially fluidized and siliconized mono ammonium phosphate dry chemical in the form of a fine pale yellow powder. ABC Fire Extinguishers can be used on Class A, B, or C fires. SPECS UL&ULC Rating: 3A:40B:C Capacity (lbs): 5Lbs Shipping Weight (lbs): 10.2 Height: 15.7 in Width: 7.3 in Depth: 4.3 in Design: Nozzle Range (Initial) : 9 15 ft Discharge time (seconds): 10 Bracket Option: Wall Mounting Bracket or Vehicle Bracket Included Temperature Range 65 F to 120 F UL Rated USCG Approved with Bracket Listed on UL Label 13

14 WET CHEMICAL EXTINGUISHERS This is used for cooking oil / fat fires. The fine spray gives almost immediate flame extinguishment while the wet chemical agent reacts with the oil. This is suitable for class A & F fires. Technical Data Model No. Capacity Fire Rating Type NT-W-6 6 liter s 13A 75F Portable 14

15 TROLLEY FIRE EXTINGUISHERS (DRY POWDER) Size: 25Kgs, 35Kgs, 50Kgs Valid time(s) 30 Nitrogen Pressure Mpa: 1.2 Insulation: 5V NT-TP-25 NT-TP-35 NT-TP-50 TROLLEY FIRE EXTINGUISHERS (CO2) Model No. NT-TC-10 Size 10 Kgs Temperature Range: 30 o C 60 o C Working Pressure(Bar): 174 Test Pressure(Bar): 250 Material: CK45 NT-TC Kgs NT-TC Kgs NT-TC-10 NT-TC-24 NT-TC-50 15

16 FIRE EXTINGUISHER Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley Extinguishers NTEICO FACTORY: Industrial Area #12 Sharjah, United Arab Emirates Tel: Fax: NTEICO DUBAI OFFICE: Tower Business Bay, P.O. Box: , Dubai, United Arab Emirates Tel: Fax:

PORTABLE FIRE EXTINGUISHERS. Fire Safety.

PORTABLE FIRE EXTINGUISHERS. Fire Safety. WHAT THE RATINGS MEAN: The New Zealand Standard for classifiying, rating, and performance testing of Fire Extinguishers (AS/NZ1850:1997), was introduced at the request of manufacturers, who wanted a method

More information

Powder Extinguisher ABC (stored pressure) Portable powder extinguishers

Powder Extinguisher ABC (stored pressure) Portable powder extinguishers Powder Extinguisher ABC (stored pressure) Portable powder extinguishers The Dräger powder extinguisher are an all-purpose fire extinguisher and are especially suited for flammable liquids and fires involving

More information

Twin-Agent Fire Fighting/Securing Systems Specifications

Twin-Agent Fire Fighting/Securing Systems Specifications Twin-Agent Fire Fighting/Securing Systems Specifications Models 450/50, 450/100, 900/100 & 1350/200 INDEX 1.0 GENERAL 1.1 References 1.2 Submittals 1.3 System Capabilities 1.4 Quality Control 1.5 Warranty,

More information

OPTIONAL INFORMATION PORTABLE FIRE EXTINGUISHERS SELF INSPECTION CHECKLIST

OPTIONAL INFORMATION PORTABLE FIRE EXTINGUISHERS SELF INSPECTION CHECKLIST OPTIONAL INFORMATION Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: PORTABLE FIRE EXTINGUISHERS Guidelines: This checklist covers the "Uniform Fire Code" regulations

More information

A full range of UK manufactured portable and wheeled fire extinguishers

A full range of UK manufactured portable and wheeled fire extinguishers NORFOLK WHEELED BRITANNIA P50 BRITANNIA BLAZEX BRITANNIA MONNEX A full range of UK manufactured portable and wheeled fire extinguishers BRITANNIA MARINE EN1866 Hong Kong Fire Service Ref No. ECL/FSD/L/50R1/2012

More information

Flammable liquids, gasoline, oil etc. Advantages. 21 B. Ø 920 mm 21 B. Ø 920 mm

Flammable liquids, gasoline, oil etc. Advantages. 21 B. Ø 920 mm 21 B. Ø 920 mm 1370 14133 14133 Powder Wheeled Fire Extinguisher kg 25 Approved EN 166-1:200, Marina MED, higest rate achieved - A IVB C CSI Certificate MED/0497/126/09 Organic solid materials, wood rubber, textiles

More information

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop STORED PRESSURE 50, 125/150 lb. Stored Pressure These commercial stored pressure extinguishers are available in a choice of two sizes and three chemical options. The carriage design on both sizes provides

More information

Portable wet chemical extinguishers

Portable wet chemical extinguishers Wet Chemical Extinguisher 6 liter AF Portable wet chemical extinguishers Wet chemical extinguishers are the best restaurant kitchen appliance hand portable fire extinguishers you can purchase. Each model

More information

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers READY FOR ACTION WHEN YOU ARE. Every year, cooking accidents, unattended candles, electrical failures, careless smoking and other incidents

More information

Portable & Mobile Fire Extinguishers MARINE EQUIPMENT DIRECTIVE (MED - WHEELMARK) 2017 EDITION 1

Portable & Mobile Fire Extinguishers MARINE EQUIPMENT DIRECTIVE (MED - WHEELMARK) 2017 EDITION 1 Portable & Mobile Fire Extinguishers MARINE EQUIPMENT DIRECTIVE (MED - WHEELMARK) 0029 2017 EDITION 1 CORPORATE PROFILE EVERSAFE EXTINGUISHER SDN. BHD. (053162-V) 1 2 3 About Us: Eversafe Extinguisher

More information

Foam Wheeled Extinguisher AB Movable fire extinguishers

Foam Wheeled Extinguisher AB Movable fire extinguishers Foam Wheeled Extinguisher AB Movable fire extinguishers Wheeled extinguishers are designed for professional use under servere circumstances, resulting in a high level of quality and ease of use. Ease of

More information

Powder Extinguisher ABC - composite Portable powder extinguishers

Powder Extinguisher ABC - composite Portable powder extinguishers Powder Extinguisher ABC - composite Portable powder extinguishers The revolution in portable fire extinguishers: composite extinguishers are the latest development in the quest for durable ccorrosion resistant

More information

Fire Extinguisher Training

Fire Extinguisher Training Fire Extinguisher Training The Fire Triangle Fire Safety, at its most basic, is based upon the principle of keeping fuel sources and ignition sources separate. The Fire Triangle Three things must be present

More information

SPECIALIST IN FIRE SAFETY PRODUCTS PRODUCT GUIDE

SPECIALIST IN FIRE SAFETY PRODUCTS PRODUCT GUIDE PRODUCT GUIDE 1.0KG MEGAFIRE ABE RATING 1A:20B:E ME11ABE 3.6MM 1.0KG 1.0KG 1.8KG WORKING PRESSURE: 1000KPA AT 23 C 90MM 265MM 25668-DC-6321 NICKEL PLATED 8 SECONDS MegaFire s compact 1.0KG extinguisher

More information

Portable Fire Extinguishers

Portable Fire Extinguishers Portable Fire Extinguishers Objectives (1 of 2) State the primary purposes of fire extinguishers. Define Class A fires. Define Class B fires. Define Class C fires. Define Class D fires. Define Class K

More information

Salt Lake Community College FIRE EXTINGUISHER TRAINING

Salt Lake Community College FIRE EXTINGUISHER TRAINING Salt Lake Community College Legal Basis for Training Occupational Safety and Health Administration (OSHA) Occupational Safety and Health Standards 29 CFR Part 1910 Subpart L Fire Protection Standard 1910.157

More information

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL NO. 05602 FOR AMEREX STORED PRESSURE, HAND PORTABLE DRY CHEMICAL FIRE EXTINGUISHERS. ABC (Ammonium Phosphate Base)

More information

Technical Data Sheet No. JS-SM-33 DOCUMENT TITLE. 2.0kg ABE TYPE STORED PRESSURE DRY POWDER PORTABLE FIRE EXTINGUISHER MODEL: R2.

Technical Data Sheet No. JS-SM-33 DOCUMENT TITLE. 2.0kg ABE TYPE STORED PRESSURE DRY POWDER PORTABLE FIRE EXTINGUISHER MODEL: R2. PAGE: ISSUE: DATE: of A 00 0745 DOCUMENT TITLE 2.0kg ABE TYPE STORED PRESSURE DRY POWDER PORTABLE FIRE EXTINGUISHER MODEL: R2.0ABE O 0745 ISSUED FOR USE AS ISSUE A WJJ LRL LHG REV DATE REVISION DESCRIPTION

More information

& Fire Extinguisher Training

& Fire Extinguisher Training & Fire Extinguisher Training D The fire is an exothermic reaction. Ignition Flammable material + air (O2) ----------> CO 2 +H 2 O+Heat Temperature The evolved heat will further promote the reaction to

More information

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual 008094 All fire extinguishers should be installed, inspected and maintained in accordance with

More information

PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers

PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers MODEL 5 The Model 5 has a slim design for use on vehicles and machinery where space is limited. Typical applications include small trucks,

More information

COMPONENT MAINTENANCE MANUAL

COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST HALON 1/ 1,2/ 2,5 AIR TOTAL List of Portable Fire Extinguishers Part No. Type: 74-00 HAL 1,0 74-20 HAL 1,2 74-21 HAL 1,2 (LH) 76-00 HAL 2,5 COMPONENT MAINTENANCE MANUAL TOTAL

More information

Foam Extinguisher AB - composite Portable foam extinguishers

Foam Extinguisher AB - composite Portable foam extinguishers Foam Extinguisher AB - composite Portable foam extinguishers The revolution in portable fire extinguishers: composite extinguishers are durable ccorrosion resistant and low maintenance extinguishers. The

More information

Our Honesty. Our Expertise. Your Safety.

Our Honesty. Our Expertise. Your Safety. Since 2010 Our Honesty. Our Expertise. Your Safety. PROFILE Since 2010, Safe Equipment Trading LLC is rapidly developing as an Industrial equipments trading company in UAE focusing on high quality equipments

More information

TRAINING BULLETIN TOOLS 1 May 27, 2011 PRESSURIZED WATER EXTINGUISHER

TRAINING BULLETIN TOOLS 1 May 27, 2011 PRESSURIZED WATER EXTINGUISHER TRAINING BULLETIN TOOLS 1 May 27, 2011 1. DESCRIPTION Weight is approximately 30 lbs. Water 2½ gallons. Operating Pressure: 100 psi @ 70 degrees F. Note: Water expelled in 55 seconds. Stainless Steel Cylinder

More information

Product Catalog. Your Source for World Class Fire Protection Equipment. Hand Held Extinguishers. Restaurant Fire Suppression Systems

Product Catalog. Your Source for World Class Fire Protection Equipment. Hand Held Extinguishers. Restaurant Fire Suppression Systems Product Catalog Your Source for World Class Fire Protection Equipment Foam Concentrates & Hardware Restaurant Fire Suppression Systems Hand Held Extinguishers Wheeled & Specialty Fire Extinguishers 1 Hand

More information

CO ALARMS GAS DETECTION HYDRANT BOOSTERS MOUNTS PUMP SOLUTIONS SUPPRESSION SYSTEMS. /fireprotection

CO ALARMS GAS DETECTION HYDRANT BOOSTERS MOUNTS PUMP SOLUTIONS SUPPRESSION SYSTEMS. /fireprotection FIRE PROTECTION CO ALARMS GAS DETECTION HYDRANT BOOSTERS MOUNTS SPRINKLER PUMP SOLUTIONS SUPPRESSION SYSTEMS Shop /fireprotection 1.800.323.0244 EDARLEY.COM/FIREPROTECTION FIRE PROTECTION HALOTRON I CLEAN

More information

w w a. m o c. x e r fi. w u

w w a. m o c. x e r fi. w u 1300 246 247 www.firex.com.au sales@firex.com.au Contents 1. About Firex 03 2. Fire Extinguishers 04 3. Fire Hose Reels 10 4. Fire Blankets 11 5. Accessories 12 6. Extinguisher Spare Parts 16 7. Fire Cabinets

More information

PRODUCT MANUAL FIRE EXTINGUISHER

PRODUCT MANUAL FIRE EXTINGUISHER PRODUCT MANUAL FIRE EXTINGUISHER Clean Agent (FE-36) 2, 4 & 6 Kg Capacity Kanadia Fyr Fyter Pvt Ltd Laxminagar, Ghatkopar (E), Mumbai -400 075 Page 1 of 5 INTRODUCTION [KANEX FIRE EXTINGUISHER] Store Pressure

More information

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6 BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6 1. Purpose This policy sets forth requirements for preventing and detecting fires, sounding an alarm, and suppressing fires. Fire protection

More information

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST) TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST) TRUCK, FIRE FIGHTING, 4x4, MODEL 1350 PKP/200 AFFF NSN 4210-00-484-5729

More information

HIGH PERFORMANCE HEAVY DUTY INDUSTRIAL STORED PRESSURE

HIGH PERFORMANCE HEAVY DUTY INDUSTRIAL STORED PRESSURE HIGH PERFORMANCE HEAVY DUTY INDUSTRIAL STORED PRESSURE ABC (AMMONIUM PHOSPHATE BASE),Regular (SODIUM BICARBONATE BASE), PURPKE K (POTASSIUM BICARBONATE BASE) OWNERS SERVICE MANUAL NO. 0566 INSTALLATION,

More information

COGEN CONSULT. Page 1 of 23

COGEN CONSULT. Page 1 of 23 KOJEN FIRE FIGHTING SYSTEMS DESIGN WE DESIGN EXECUTE - AS PER NFPA FOLLOWING SAFETIES METHODS ARE ASSENTIAL FOR INDUSTRIAL-OFFICES-COMMERCIAL-DOMESTIC INSTALLTIONS 1) GENERAL SURVEY AUDIT FOR FIRE TYPES

More information

+91-8048763768 Cease Fire & Electrical Services http://www.ceasefireengineers.com/ We are the supplier, trader and service provider of fire alarm equipment, fire suppression system, fire detection system,

More information

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS FIRE EXTINGUISHER REQUIREMENTS 1. All commercial cooking operations require at least one 2A10BC rated (5 or 6 pound size) fire extinguisher.

More information

"USING FIRE EXTINGUISHERS"

USING FIRE EXTINGUISHERS PRESENTER'S GUIDE "USING FIRE EXTINGUISHERS" Part of the "SAFETY MEETING KIT" Series Quality Safety and Health Products, for Today...and Tomorrow OUTLINE OF MAJOR PROGRAM POINTS The following outline summarizes

More information

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection:

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection: FIRE DEPARTMENT Kitchen Range Hood Fire Suppression System Acceptance Test Project Name: Project Address: Installer Name: Installer Address: Date of Inspection: DOCUMENTATION NO Plans have been reviewed

More information

WSU-TFREC Fire Safety Training

WSU-TFREC Fire Safety Training WSU-TFREC Fire Safety Training WSU-TFREC Locate the nearest exits, alarms and fire extinguishers to your work area Floor plans are available online: Overley Building http://www.tfrec.wsu.edu/pages/safety/overley_building_floor_plan

More information

HALOTRON I CLEAN AGENT FOR A, B & C FIRES REGULAR B:C FIRE EXTINGUISHERS PURPLE K B:C POTASSIUM BICARBONATE EXTINGUISHERS

HALOTRON I CLEAN AGENT FOR A, B & C FIRES REGULAR B:C FIRE EXTINGUISHERS PURPLE K B:C POTASSIUM BICARBONATE EXTINGUISHERS HALOTRON I CLEAN AGENT FOR A, B & C FIRES Halotron I clean fire extinguishing agent discharges as a rapidly evaporating liquid, which is non-conductive, non-corrosive, and leaves behind no residue. Determined

More information

Risk Management Department. Fire Extinguishers

Risk Management Department. Fire Extinguishers Risk Management Department Fire 1 Introduction to Fire Every school facility is equipped with fire extinguishers for staff to use to suppress fires. Used properly, a fire extinguisher can be an effective

More information

Purple K B:C Potassium Bicarbonate Extinguishers

Purple K B:C Potassium Bicarbonate Extinguishers Halotron I Clean Agent For A, B & C Fires Halotron I clean fire extinguishing agent discharges as a rapidly evaporating liquid, which is non-conductive, non-corrosive, and leaves behind no residue. Determined

More information

MSC Guidelines for Foam Fire Suppression Systems

MSC Guidelines for Foam Fire Suppression Systems References: S. T. Brady, CDR, Chief, Engineering Division a. 46 CFR 34.17, Tank Vessel Fixed Foam b. 46 CFR 34.20, Tank Vessel Deck Foam c. 46 CFR 76.17 Passenger Vessel Foam d. 46 CFR 95.17, Cargo Vessel

More information

QUALITY LEADERSHIP. Portable fire extinguishers Minimax Mobile Services. Experts in fire protection MF I 1

QUALITY LEADERSHIP. Portable fire extinguishers Minimax Mobile Services. Experts in fire protection MF I 1 QUALITY LEADERSHIP Portable fire extinguishers Minimax Mobile Services Experts in fire protection MF I 1 Minimax: Quality leadership Minimax Quality leadership in portable fire extinguishers Version: December

More information

FireIce & FireIce Shield F.A.Q.

FireIce & FireIce Shield F.A.Q. Introduction. This document is intended to provide additional information with respect to GelTech s family of FireIce and FireIce Shield products and equipment. It does not replace or supersede the respective

More information

What are the four things that must be present at the same time to produce fire?

What are the four things that must be present at the same time to produce fire? What are the four things that must be present at the same time to produce fire? Enough oxygen to sustain combustion, Enough heat to raise the material to its ignition temperature, Some sort of fuel or

More information

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY Fire Department HEADQUARTERS 4410 Cathedral Oaks Road Santa Barbara, CA 93110-1042 (805) 681-5500 FAX: (805) 681-5563 Michael W. Dyer Fire Chief County Fire Warden Eric Peterson Deputy Fire Chief CODE

More information

SERT FIRE ELEMENTS & HAZ MAT

SERT FIRE ELEMENTS & HAZ MAT SERT FIRE ELEMENTS & HAZ MAT Fire Triangle Needed elements to sustain burning Firefighter / EMT Casey McIntosh Fire Tetrahedron Added 4 th element to Fire Triangle. The Combustion Process THE FIRE TETRAHEDRON

More information

Fire extinguishers. Amicus guide

Fire extinguishers. Amicus guide Fire extinguishers Amicus Hayes Court, West Common Road, Hayes, Bromley, Kent BR2 7AU Tel: 020 8462 7755 Fax: 020 8315 8234 Website: www.amicustheunion.org Amicus guide October 2005 Amicus guide to fire

More information

Basic Vehicle Fire Protection Manual

Basic Vehicle Fire Protection Manual Basic Vehicle Fire Protection Manual Basic Vehicle Fire Protection Manual TABLE OF CONTENTS Introduction... 3 System Operation...... 5 Component Overview.... 7 Operator Controls Control Panel.........

More information

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND 1. GENERAL SPECIFICATION 1.1 A pre-engineered, fixed pipe, automatic dry chemical fire suppression system shall be provided and installed for the hazard including work area, plenums and all exhaust ventilation

More information

OWNER'S OPERATION AND MAINTENANCE MANUAL

OWNER'S OPERATION AND MAINTENANCE MANUAL OWNER'S OPERATION AND MAINTENANCE MANUAL P/N 15064 Amerex Industrial Dry Chemical Fire Suppression System MODELS IS18ABC (18 lb. ABC) / IS35ABC (35 lb. ABC) / IS45ABC (45 lb. ABC) / Manufactured by: AMEREX

More information

Evaporation The process in which a liquid dissipates or emits vapor, fumes, or invisible minute particles.

Evaporation The process in which a liquid dissipates or emits vapor, fumes, or invisible minute particles. 35 Evaporation of waste wash water occurs during normal operation of the pressure, steam or automatic vehicle wash system. It is generally assumed that 10-30% of wash water is lost to evaporation. Accelerated

More information

Osceola County Department of Fire Rescue and Emergency Medical Services

Osceola County Department of Fire Rescue and Emergency Medical Services St. Number Dir Street Name Street Type Inspected Time of Day to be Re-inspected Zip Code Occupancy Type Emergency Contact Phone (Inc. Area Code) Building Owner Building Owner Mailing Address Bldg. Owner

More information

Department of Public Safety

Department of Public Safety Terry E. Branstad Governor Kim Reynolds Lt. Governor Department of Public Safety Roxann M. Ryan Commissioner Liquid Propane Informational guide to submitting plans Plans are to be submitted to: State Fire

More information

Technical Specification For Design and supply of Water Mist cum CAFS (Compressed Air Foam System) Backpack Fire Fighting System

Technical Specification For Design and supply of Water Mist cum CAFS (Compressed Air Foam System) Backpack Fire Fighting System Technical Specification For Design and supply of Water Mist cum CAFS (Compressed Air Foam System) Backpack Fire Fighting System pg. 1 INTRODUCTION : HPCL is in the process of procurement of Water mist

More information

Fire Safety in the Laboratory

Fire Safety in the Laboratory Environmental Health and Safety Fire Safety in the Laboratory There are two kinds of fires in laboratories: planned and unplanned. In the 19 th century, chemical laboratories and college chemistry buildings

More information

Extinguishers. ABC Dry Chemical Fire Extinguisher. Carbon Dioxide Fire Extinguisher. Halotron Fire Extinguisher

Extinguishers. ABC Dry Chemical Fire Extinguisher. Carbon Dioxide Fire Extinguisher. Halotron Fire Extinguisher Extinguishers ABC Dry Chemical Fire Extinguisher ABC or multi-purpose extinguishers utilize a specially fluidized siliconized mono ammonium phosphate dry chemical, it chemically insulates Class A fires

More information

Workplace FIRE SAFETY

Workplace FIRE SAFETY Workplace FIRE SAFETY 18 1 FIRE! Fire claims the lives of over 5,000 people each year in the United States. Fire also causes thousands of disabling injuries, millions of dollars of property damage and

More information

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK STRIKE FIRST CORPORATION AKC SERVICE MANUAL (v1) UL / ULC WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK All fire extinguishers should be installed, inspected

More information

TAMUCC Fire Safety Training

TAMUCC Fire Safety Training TAMUCC Fire Safety Training TAMUCC Fire Safety Meeting Fire Chemistry, Classification, Types Fire Fighting Fire Prevention Fire Detections Fire Safety Activities TAMUCC Fire Safety Meeting Fire: A rapid

More information

Bench Series Ovens Models 21 / 31 / 51 Operating Manual

Bench Series Ovens Models 21 / 31 / 51 Operating Manual Heat cycle HEATER SWITCH RECIRC. FAN Quincy Lab, Inc. Bench Series Ovens Models 21 / 31 / 51 Operating Manual Standard Contents (1) Bench Series Oven (2) Adjustable chrome wire shelf (4) Shelf brackets

More information

A. Section Includes: Fire extinguishers and cabinets including necessary accessories.

A. Section Includes: Fire extinguishers and cabinets including necessary accessories. SECTION 10522 FIRE EXTINGUISHERS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Fire extinguishers and cabinets including necessary accessories. B. Related Sections: 1. 09900 - Painting 2. 10400 - Identifying

More information

McCormick Place Fire Safety Regulations

McCormick Place Fire Safety Regulations CANDLES AND OTHER OPEN FLAME DISPLAYS Any open flame devices used for illumination or decoration, such as candles, gelled alcohol fuel fire bowls, firepots or fireplaces must comply with the following:

More information

FIRE MY11 - FIRE RADIO MY11 SAFETY CABINETS CERTIFIED FOR THE STORAGE OF FLAMMABLE AND RADIOACTIVE PRODUCTS

FIRE MY11 - FIRE RADIO MY11 SAFETY CABINETS CERTIFIED FOR THE STORAGE OF FLAMMABLE AND RADIOACTIVE PRODUCTS FIRE MY11 - FIRE RADIO MY11 SAFETY CABINETS CERTIFIED FOR THE STORAGE OF FLAMMABLE AND RADIOACTIVE PRODUCTS CHEMISAFE FIREMY11 safety cabinet BEFORE fire resistance test. Safety cabinets for the safe storage

More information

Packaged Steam Fired Water Heater

Packaged Steam Fired Water Heater MODEL ST Packaged Steam Fired Water Heater Utilizes Steam To Heat Domestic Water, Semi-Instantaneous or Storage Type Heaters Features Reliable Packaged System Only high grade materials used in construction

More information

COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST

COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST 98 Columbus Street, Pointe Claire, QC, Canada H9R 4K4 info@caspaerospace.com www.caspaerospace.com T: 514-630-7777 F: 514-630-9999 HAND PORTABLE AIRCRAFT FIRE EXTINGUISHERS 3.0 lb. Halon 1211 Part No.

More information

Thermal Fluid Heaters

Thermal Fluid Heaters Thermal Fluid Heaters Vertical Coil, Vertical Tubeless, Electric and Horizontal Sizes from 75,000 to 40,000,000 BTU/HR The heat transfer innovators. THERMAL FLUID FEATURES AND BENEFITS KEY FEATURES No

More information

1. GENERAL SAFETY RULES

1. GENERAL SAFETY RULES ID180 & ID290 Indirect-Fired Diesel/Oil Construction Heaters Sure Flame Products Lethbridge, Alberta, Canada Telephone: (403)328-5353 Fax: (403)328-9956 www.sureflame.ca July 12, 2006 Service and Maintenance

More information

ASME Packaged Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining provides superior protection and tank longevity Heavy duty construction withstands

More information

Fire Hazard Identification Checklist 1

Fire Hazard Identification Checklist 1 Fire Hazard Identification Checklist 1 (Component of a BC Fire Code (BCFC) compliance inspection) Date: BUILDING INFORMATION Company name: Building Name: Address: Street # and name City/Province Postal

More information

DRY CHEMICAL AND CLEAN AGENT HAND PORTABLE FIRE EXTINGUISHERS

DRY CHEMICAL AND CLEAN AGENT HAND PORTABLE FIRE EXTINGUISHERS DRY CHEMICAL AND CLEAN AGENT HAND PORTABLE FIRE EXTINGUISHERS OPERATION, RECHARGE, INSPECTION, AND MAINTENANCE MANUAL 000769 One Stanton Street / Marinette, WI 54143-2542, USA / +1-715-735-7411 Copyright

More information

UL LISTED. SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed. RESPONSE Quick response Standard response

UL LISTED. SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed. RESPONSE Quick response Standard response SPRINKLER HEADS SMOOTHFLOW AUSTRALIA SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed RESPONSE Quick response Standard response COLOURS Natural brass Chromed Power coated white TEMPERATURE

More information

Technical Data Approvals UL Listed and FM Approved. Refer to Tables 1, 2, and 3, as applicable.

Technical Data Approvals UL Listed and FM Approved. Refer to Tables 1, 2, and 3, as applicable. Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Customer Service/Sales: Tel: (215) 362-0700 / (800) 523-6512 Fax: (215) 362-5385 Approved Discharge Devices For Use With Ansul Foam Concentrates

More information

Marine Fire Protection. Kidde Residential and Commercial Division 1394 South Third Street, Mebane, NC Tel

Marine Fire Protection. Kidde Residential and Commercial Division 1394 South Third Street, Mebane, NC Tel Marine Fire Protection 1 D I S P O S A B L E FIRE EXTINGUISHER Marine 210D MPWC Fire Extinguisher Part number 43 Regular use UL Rated 5-B:C Suitable for use on Class B (liquids & gases) and Class The PWC

More information

PHIREX AUSTRALIA CATALOGUE & DATA SHEETS. April 2005, Rev 2. Fogex Water Mist Fire Protection System Components PHX-3064

PHIREX AUSTRALIA CATALOGUE & DATA SHEETS. April 2005, Rev 2. Fogex Water Mist Fire Protection System Components PHX-3064 CATALOGUE & S April 2005, Rev 2 PHX-3064 Fogex Water Mist Fire Protection System Components Fogex F11 Water Mist Nozzle Fogex F11 Water Mist Nozzle Features Al. Bronze construction for added safety and

More information

June 2013 Safety Meeting Fire Extinguishers Part II

June 2013 Safety Meeting Fire Extinguishers Part II June 2013 Safety Meeting Fire Extinguishers Part II Fire safety should be a major concern of all propane employees. It is important that employees be properly trained in the use of extinguishers before

More information

DESIGN, INSTALLATION, OPERATION, AND MAINTENANCE MANUAL DRY CHEMICAL SELF-CONTAINED AUTOMATIC EXTINGUISHER UNIT

DESIGN, INSTALLATION, OPERATION, AND MAINTENANCE MANUAL DRY CHEMICAL SELF-CONTAINED AUTOMATIC EXTINGUISHER UNIT DESIGN, INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR DRY CHEMICAL SELF-CONTAINED AUTOMATIC EXTINGUISHER UNIT Models: 940202-2.5 lbs 940502-5 lbs 941002-10 lbs 942002-20 lbs P/N 800010 U.L. EX5323

More information

>>> FIRE MY11 >>> ACCORDING TO VERSIONS NEW SAFETY CABINETS CERTIFIED TYPE 90 FOR THE STORAGE OF FLAMMABLE PRODUCTS

>>> FIRE MY11 >>> ACCORDING TO VERSIONS NEW SAFETY CABINETS CERTIFIED TYPE 90 FOR THE STORAGE OF FLAMMABLE PRODUCTS >>> FIRE MY11 NEW SAFETY CABINETS CERTIFIED TYPE 90 FOR THE STORAGE OF FLAMMABLE PRODUCTS >>> ACCORDING TO VERSIONS WE OFFER AN INCREASED STORAGE CAPACITY OF 20/25% >>> ADVANTAGE OF PARTS REPLACEMENT IN

More information

Safety & Risk Management Policies and Procedures

Safety & Risk Management Policies and Procedures Title: Date: July 2014 Safety & Risk Management Policies and Procedures Rationale: The fire safety policy plan is necessary to create a campus-wide system for preventing and/or responding to potential

More information

Ceasefire Watermist Hydrant Systems

Ceasefire Watermist Hydrant Systems No fire is too big to beat. Ceasefire Watermist Hydrant Systems Never underestimate a fire. With enough oxygen and other fuels, even the smallest flame can turn into a full-scale blaze, destroying everything

More information

APPENDIX A FEES SECTION FC A01 CERTIFICATES A01.1

APPENDIX A FEES SECTION FC A01 CERTIFICATES A01.1 FEES SECTION FC A01 CERTIFICATES A01.1 Certificate fees. Applicants for certificates required pursuant to the provisions of this code or the rules shall pay the fees specified in this section. Fees for

More information

Item Referenced and Amendments Building 1 Building 2 Analysis, Review and Remarks. Page 1 of 15

Item Referenced and Amendments Building 1 Building 2 Analysis, Review and Remarks. Page 1 of 15 N/A N/A 2015 International Fire Code 2015 International Building Code Codes Jurisdictions for Fire and Building Codes Source of Information Building Fire Plumbing Mechanical Electrical Energy Code Accessibility

More information

SUPPORT EQUIPMENT MODULAR RAPIDLY DEPLOYABLE MOBILE RUGGED RELIABLE VERSATILE

SUPPORT EQUIPMENT MODULAR RAPIDLY DEPLOYABLE MOBILE RUGGED RELIABLE VERSATILE SUPPORT EQUIPMENT MODULAR RAPIDLY DEPLOYABLE MOBILE RUGGED RELIABLE VERSATILE SUPPORT EQUIPMENT Deployable Rapid Assembly Shelter (DRASH) Support Equipment are shelter components that can be used to enhance

More information

GENERAL FIRE REQUIREMENTS SELF INSPECTION CHECKLIST

GENERAL FIRE REQUIREMENTS SELF INSPECTION CHECKLIST OPTIONAL INFORMATION Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: GENERAL FIRE REQUIREMENTS SELF INSPECTION CHECKLIST Guidelines: This checklist covers some

More information

Fire Hazard Identification Checklist 1

Fire Hazard Identification Checklist 1 Fire Hazard Identification Checklist 1 (Component of a BC Fire Code (BCFC) compliance inspection) Date: BUILDING INFORMATION Company name: Building Name: Address: Street # and name City/Province Postal

More information

Corn Flame Energy Corn Stove Model 3000

Corn Flame Energy Corn Stove Model 3000 Corn Flame Energy Corn Stove Model 3000 Installation and Operation Guide Read thoroughly before starting installation Save this manual for future reference SAFETY NOTICE If this stove is not properly installed,

More information

Kitemark Certificate No. KM

Kitemark Certificate No. KM Kitemark Certificate No. KM 668606 This is to certify that: Saudi Factory For Fire Equipment Co. 2nd Industrial City Wasel No.7275 Unit 1, Street 234 Al Kharj Road, PO Box 4441 Riyadh 14334 Kingdom of

More information

ClassNK Technical Information No. TEC-0970 For any questions about the above, please contact: NIPPON KAIJI KYOKAI (ClassNK) Survey Department, Adminis

ClassNK Technical Information No. TEC-0970 For any questions about the above, please contact: NIPPON KAIJI KYOKAI (ClassNK) Survey Department, Adminis Subject Maintenance, inspection and test of Fire-Protection Systems and Appliances on board the Panama-registered ships To whom it may concern Technical Information No. TEC-0970 Date 31 October 2013 The

More information

Portable Fire Extinguishers

Portable Fire Extinguishers Portable Fire Extinguishers 2 Welcome to TOTAL Why TOTAL? When you buy TOTAL portable fire extinguishers, you can be sure you are choosing from a range of top quality products, built on 100 years of experience

More information

City of Cleveland. Division of Fire Fire Prevention Bureau 1645 Superior Avenue Cleveland, Ohio Standard Operating Procedure 18

City of Cleveland. Division of Fire Fire Prevention Bureau 1645 Superior Avenue Cleveland, Ohio Standard Operating Procedure 18 City of Cleveland Division of Fire Fire Prevention Bureau 1645 Superior Avenue Cleveland, Ohio 44114 216.664.6664 Standard Operating Procedure 18 Cleveland Fire Prevention Fire Safety Regulations for Displays

More information

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages MODEL SE Commercial Electric Water Heater 6-119 Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages Features Heavy Duty Construction High Efficiency Polyurethane

More information

ASME Packaged Electric Water Heater

ASME Packaged Electric Water Heater MODEL SH & H ASME Packaged Electric Water Heater 15-1600 KW - All Voltages & Phases, 80-5000 Gallon Capacity Features Reliable Packaged System Only high grade materials used in construction to ensure long

More information

GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems

GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems GAS EXTINGUISHING SYSTEMS Argon Extinguishing Systems Fire Protection Systems EFFECTIVE NATURAL no damage to the atmosphere technology for complex applications EXAMPLE GAS EXTINGUISHING SYSTEMS solution

More information

AS Australian Standard. Portable fire extinguishers Guide to servicing. This is a free 7 page sample. Access the full version online.

AS Australian Standard. Portable fire extinguishers Guide to servicing. This is a free 7 page sample. Access the full version online. AS 3676 1989 Australian Standard Portable fire extinguishers Guide to servicing This Australian Standard was prepared by Committee FP/3, Fire Extinguishers. It was approved on behalf of the Council of

More information

Exploration and extraction can be on land or on offshore platforms. Once extracted, ground transportation is done by means of oil or gas pipelines,

Exploration and extraction can be on land or on offshore platforms. Once extracted, ground transportation is done by means of oil or gas pipelines, Oil & Gas Exploration and extraction can be on land or on offshore platforms. Once extracted, ground transportation is done by means of oil or gas pipelines, FPSO vessels, tankers, LNG carriers, etc. The

More information

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D PL 17819 01 00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 29.06.2017 to 10.08.2019 Holder of certificate: MPA

More information

In the year 1988, Amit Industrial Corporation is a reputed name in the industry for Manufacturing and

In the year 1988, Amit Industrial Corporation is a reputed name in the industry for Manufacturing and +91-8042973396 Amit Industrial Corporation https://www.indiamart.com/amitindustrialcorporation/ In the year 1988, Amit Industrial Corporation is a reputed name in the industry for Manufacturing and Supplying

More information

LP GAS PIZZA OVEN USER MANUAL

LP GAS PIZZA OVEN USER MANUAL LP GAS PIZZA OVEN USER MANUAL To reduce the risk of fire, burn hazard or other injury, read the USER MANUAL carefully and completely before using this appliance FOR OUTDOOR USE ONLY Before Cleaning, make

More information

FUEL. Fire & Flammable Liquids Properties. Flammable & Combustible Liquid Safety. Safety. Practice. Laws: OSHA & NFPA. Safety.

FUEL. Fire & Flammable Liquids Properties. Flammable & Combustible Liquid Safety. Safety. Practice. Laws: OSHA & NFPA. Safety. FLAMMABLE & COMBUSTIBLE LIQUID SAFETY WHAT YOU DON T KNOW CAN BURN YOU! Operations, Department, Health & Safety or Purchasing Managers Compliant with OSHA, NFPA, EPA, and to Industry Best Practices Flammable/Combustible

More information

Mini Spray Dryer B-290 Technical data sheet

Mini Spray Dryer B-290 Technical data sheet Mini Spray Dryer B-290 Technical data sheet The Mini Spray Dryer B-290 is the world leading laboratory scale Spray Dryer since many years. It is designed to visualize your Spray Drying process for wide

More information