ELECTRO-FENCE TM. Fence Protection System. Installation Manual. EF_Install_V2
|
|
- Godwin Walters
- 6 years ago
- Views:
Transcription
1 ELECTRO-FENCE TM Fence Protection System Installation Manual EF_Install_V2 Advanced Perimeter Systems Ltd., 16 Cunningham Road, Springkerse Industrial Estate, Stirling, FK7 7TP Tel: +44 (0) Fax: +44 (0) Web site:
2 Contents Page 1 ZONE END WIRING m Standard Electro-Fence m High Security Electro-Fence m Electro-Fence m High Security Electro-Fence m Standard Wall Top m High Security Wall Top GATE WIRING SINGLE LEAF GATE DOUBLE LEAF GATE ELECTRO-FENCE CONTROLLERS TYPE EF102, EF122 DUAL ZONE Low Voltage (LV) Fence connections. (EF122 only) Type EF106 6 Zone Connections... 12
3 1 ZONE END WIRING m Standard Electro-Fence The Electro-Fence should be wired as shown below. The output from the controller should be connected to the top wire (wire 1) and then wire 24 should be connected to the controller input. All earth wires are connected in parallel at each end of the zone and at each end section or corner section. The warning signs must be fitted across two earth wires. Page 1
4 m High Security Electro-Fence The Electro-Fence should be wired as shown below. The H.V. output from the controller should be connected to wire 1 and the L.V. output should be connected to wire 2. Wire 24 should be connected to the controller H.V. input and wire 25 should be connected to the L.V input. Page 2
5 m Electro-Fence The Electro-Fence should be wired as shown below. The output from the controller should be connected to the top wire (wire 1) and then wire 31 should be connected to the controller input. All earth wires are connected in parallel at each end of the zone and at each end section or corner section. The warning signs must be fitted across two earth wires. Page 3
6 m High Security Electro-Fence The Electro-Fence should be wired as shown below. The H.V. output from the controller should be connected to wire 1 and the L.V. output should be connected to wire 2. Wire 31 should be connected to the controller H.V. input and wire 32 should be connected to the L.V input. Page 4
7 m Standard Wall Top On wall toppings, the top and bottom wires of the Electro-Fence are high voltage wires. Wire 1 connects to the controller output and wire 11 is connected to the controller input m High Security Wall Top The H.V. output from the controller should be connected to wire 1 and the L.V. output connected to wire 2. Wire 11 should be connected the to controller H.V. and wire 10 to the L.V. input. Page 5
8 2 GATE WIRING The gate switch should be fitted as close to the locking bolt as possible as this point should have the least movement when the gate is closed. The gate should be wired as shown below so that when the gate is opened the voltage is removed from the zone except for the top wire which is the feed from the controller. When wiring the earth wire on the gate, it is only necessary to connect the earth wires in parallel at the hinge side of the gate. The earth must be continued from one side of the gate to the other using EF-400 lead out cable fitted in a protective conduit and buried in the ground under the gate. 2.1 SINGLE LEAF GATE 2.2 DOUBLE LEAF GATE Page 6
9 3 ELECTRO-FENCE CONTROLLERS 3.1 TYPE EF102, EF122 DUAL ZONE High Voltage (HV) Fence connections. (EF102 and EF122) Connect the earth stakes to the black Fence Earth terminal. Connect the high voltage fence loop for Zone 1 to terminals HV1 OUT and HV1 IN. Terminal HV1 OUT is the High Voltage Output terminal and this connects to the top high voltage fence wire. Terminal HV1 IN is the High Voltage Input terminal and this connects to the bottom high voltage fence wire. The high voltage fence loop for Zone 2 connects to terminals HV2 OUT and HV2 IN. HV Alarm output connections All the alarm outputs are normally closed volt free relay contacts. HV1 ALARM Alarm relay output for HV Zone 1. HV2 ALARM Alarm relay output for HV Zone 2. TAMPER Box tamper microswitch output. POWER FAIL Mains fail relay output. Note, when the controller is switched off the HV alarm relays will be open and will rest within 3 seconds of the controller being switched on provided that the fence is clear and not in alarm. If the controller is connected to a standard intruder alarm panel then the alarm panel inputs should be set as access zones with a delay time of 5 seconds. This is to allow the HV alarm relays time to close. Page 7
10 Control input (HV on/off) The controller will switch on and start pulsing when 12VDC is applied to the CONTROL INPUT. Make sure that the polarity is correct as the controller will not switch on if the polarity is incorrect. The 12VDC can be supplied from the Set/Unset output of the alarm panel, from the auxiliary 12V output or a separate power supply unit using a key switch. HV Alarm Voltage Setting When the HV voltage on the fence is reduced below the HV alarm voltage setting then the pulse counter starts to count missing pulses. When the set number of missing pulses are counted, the alarm will be activated. Switches 1 and 2 are used to set the voltage as follows: HV VOLTAGE S1 S2 2KV OFF OFF 3KV ON OFF 4KV OFF ON Page 8
11 Pulse Count Setting The number of missing pulses is set using S3 and S4 as follows: PULSES S3 S4 1 ON OFF 2 OFF ON 3 OFF OFF HV LED Indicators There are 6 LED test indicators located on the PCB. The function of each indicator is as follows: HV1 ALARM This will be lit when HV Zone 1 is in alarm and when the controller is switched off. HV2 ALARM This will be lit when HV Zone 2 is in alarm and when the controller is switched off. OK1 This will pulse if the controller is switched on and the voltage on the HV1 In terminal is greater that the alarm voltage setting showing that the fence is working OK. It will not flash if the fence is in alarm. OK2 This will pulse if the controller is switched on and the voltage on the HV2 In terminal is greater that the alarm voltage setting showing that the fence is working OK. It will not flash if the fence is in alarm. Power This will be lit if the mains power is present. If the mains fails then the LED will go out and the Power fail relay will open. Pulse This will pulse when the controller is switched on showing that the energiser is producing the high voltage. The Pulse LED is located near the top right of the PCB. Page 9
12 3.2 Low Voltage (LV) Fence connections. (EF122 only) Connect the LV EARTH wire onto the LV EARTH terminal on the HV PCB. Connect the low voltage fence loop for LV Zone 1 to terminals LV1 OUT and LV1 IN. Terminal LV1 OUT is the Low Voltage Output terminal and this connects to the top low voltage fence wire. Terminal LV1 IN is the Low Voltage Input terminal and this connects to the bottom low voltage fence wire. The low voltage fence loop for Zone 2 connects to terminals LV2 OUT and LV2 IN. LV Alarm output connections All the alarm outputs are normally closed volt free relay contacts. LV1 ALARM Alarm relay output for LV Zone 1. LV2 ALARM Alarm relay output for LV Zone 2. Page 10
13 LV LED Indicators The function of each indicator is as follows: LV1 ALARM This will be lit when LV Zone 1 is in alarm. HV2 ALARM This will be lit when LV Zone 2 is in alarm. The alarm will activate under the following conditions 1. A short between an HV wire and an LV wire 2. An LV wire is cut 3. A short between an LV wire and earth Page 11
14 3.3 Type EF106 6 Zone Connections ALARM VOLTAGE SETTING The fence voltage at which the pulse counter starts to count is set using switches 1 and 2 as follows: VOLTAGE S1 S2 2KV OFF OFF 3KV ON OFF 4KV OFF ON PULSE COUNT SETTING The number of pulses below the alarm voltage is set using switches 3 and 4 as follows: PULSES S3 S4 2 ON OFF 3 OFF ON 4 OFF OFF ALARM OUTPUTS All alarm outputs are normally closed dry contacts. CONTROL INPUT In order to activate the energiser, an external 12VDC input must be applied to the control input. This can be supplied from the auxiliary 12V output of the control panel via a keyswitch. Page 12
ZM1 User Manual JVA TECHNOLOGIES.
ZM1 User Manual JVA TECHNOLOGIES www.jva-fence.com Contents 1 Introduction.... 6 1.1 Equipment Requirements and Options..................... 6 1.1.1 Requirements.....................................6 1.1.2
More informationZLM4 OEM Technical Manual
ZLM4 OEM Technical Manual Version 3, June 2014 JVA Technologies Pty Ltd Page 1 of 32 Issue:1/08/2014 10:49:00 AM Contents INTRODUCTION... 4 Scope and Purpose... 4 DRAFT... 4 Features... 5 Limitations...
More informationZM20 OEM Technical Manual
ZM20 OEM Technical Manual Version 15, January 2016 JVA Technologies Pty Ltd Page 1 of 43 Issue:8/01/2018 10:43:00 AM Contents INTRODUCTION... 4 Scope and Purpose... 4 FEATURES... 5 Limitations... 5 Equipment
More informationELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description
Loop Detector is used to detect metal objects such as motor vehicles, motor bikes or trucks. ELSEMA Features Wide supply range: 12.0 to 24 Volts DC 16.0 to 24 Volts AC Selectable sensitivity Pulse or Presence
More informationPakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504
Remote Monitor PTE0700 SECURITY ELECTRONICS User Manual PTE0700 V2 Series Remote Monitor Pakton Technologies Pty Ltd ABN 66 405 694 842 16 Ferrier Road, Narangba Qld 4504 PO Box 408, Narangba QLD 4504
More informationPTE0705 Electric Fence Monitor
PTE0705 Electric Fence Monitor The JVA logo is a registered trademark of JVA Technologies. JVA Technologies. TABLE OF CONTENTS DESCRIPTION... 2 QUICK START GUIDE... 3 FEATURES... 4 EXPLANATION OF TERMS...
More informationD-Tect 2 GJD300 Quad PIR Movement Detector
D-Tect GJD0 Quad PIR Movement Detector Package Contents 3. Package Contains: x D-Tect x Drilling template for fixing holes x Allen Key 3 x 3.75mm wall plugs 3 x 3.75mm screws x Spare Sliding Curtains x
More informationExit Stopper. STI-6400 Series
Exit Stopper STI-6400 Series Features Alarm helps prevent unauthorized exits/entries through doors. Easy to install. Select volume, alarm duration and delay settings. May be mounted on top, right, left
More informationD-TECT Dual Tech. GJD360 Triple Technology External Detector
D-TECT Dual Tech GJD360 Triple Technology External Detector PACKAGE CONTENTS 1 x Dual Tech 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare Sliding Curtains 2
More informationJVA Electric Security Fence System. perimeter intruder detection system
JVA Electric Security Fence System perimeter intruder detection system Today's society has changed a lot over the previous years. Crime rate have gone up. Criminals have become bolder and more dangerous.
More informationOperating Instructions
D-TEK PCB-1 Vehicle Loop Detector Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment you are connecting this
More informationExit Stopper. STI-6400 Series
Exit Stopper STI-6400 Series Features Alarm helps prevent unauthorized exits/entries through doors. Easy to install. Select volume, duration and immediate or 15 second delay for arming and trip. May be
More informationMovement Detector GJD 300
Movement Detector GJD 300 Installation & Set Up Guide Introduction A CCTV event trigger utilising two independent passive infrared detectors combined in a T05 package. Both sensors have to trigger before
More informationMD12-2 Vehicle Loop Detector
MD12-2 Vehicle Loop Detector Features Supply 12VDC Adjustable sensitivity (8 levels via dip switch) 2 x Relay outputs (each can be configured individually) Power up and loop activation LED indicator. Industry
More informationSecura Pulse Deterrence and detection.
Secura Pulse Deterrence and detection www.betafence.com Secura Pulse, Betafence quality The drive for quality is the common thread running throughout the Betafence product range and is assured day after
More informationExcellence in Level Measurement
Technical Data Sheet No. Novaflo 2000 'Fail-Safe' Level Alarm System Excellence in Level Measurement Afriso Eurogauge Ltd Imberhorne Lane, East Grinstead West Sussex. RH19 1RF Tel: 01342 323641 Fax: 01342
More information1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER
Application The unit is primarily intended for use where there is a requirement to integrate a limited fire protection function into a larger control equipment scheme, or in specialist applications where
More informationRELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:
RELEASE DEVICES MADE IN THE U.S.A. RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION: S/N: The "WPS" World Power Series, Time Delay Release
More informationOperating Instructions
LP D-TEK Vehicle Loop Detector Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment you are connecting this
More informationFirefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL
Firefly II Multi Voltage RELEASE DEVICES Firefly II & IIB-MV INSTALLATION MANUAL GENERAL DESCRIPTION: S/N The The Cookson Company Firefly II-MV time delay release devices are designed for use on rolling
More informationD-TECT 3 IP. GJD260 IP Motion Detector
D-TECT 3 IP GJD260 IP Motion Detector PACKAGE CONTENTS 1 x D-TECT 3 IP 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare sliding curtains 2 x Tamper feet 1 x Tamper
More informationSOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL
S S S S S S LISTED L * PATENT PENDING S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT U 99Y9 RESET RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE
More informationINTREPID Perimeter Intrusion Detection System
TM INTREPID Perimeter Intrusion Detection System Next Generation Perimeter Protection icropoint Cable combines patented Southwest Microwave technology with microprocessor power and laptop computer convenience.
More informationELECTRIC FENCE MONITOR
M1 ELECTRIC FENCE MONITOR Installation and User Manual 2nd Edition, 2013 JVA ELECTRIC FENCE SYSTEMS JVA Z Energizer Range Concept Thank you for choosing our product. The JVA brand is a range of electric
More informationD-TECT 2 IP. GJD230 IP Motion Detector
D-TECT 2 IP GJD230 IP Motion Detector PACKAGE CONTENTS 1 x D-TECT 2 IP 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare sliding curtains 2 x Tamper feet 1 x Tamper
More informationAddendum for STI-6406 with Dual Access Control
Addendum for STI-6406 with Dual Access Control Description: This system contains a STI-6400 with a DPDT key switch to be mounted on one side of a door or wall; and a similar looking housing, also with
More informationACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F
II 1400-2 ACSI 1406-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F INSTALLATION Transformer Model BE31763001 by Basler Electric, Transformer Model 2010028 by Galaxy
More informationGas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1
Gas Safety Products Merlin CT1650+ Gas Interlock System Installation, operating and maintenance 09/05/2016 S&S Northern Ltd 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Panel
More informationDUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3
DUCT AIR HEATER WITH BUILT-IN CONTROLS Installation & User Instructions Stock Ref. 105 31 100 T1 105 31 125 T1 105 31 150 T1 105 31 200 T1 105 31 250 T1 105 31 315 T1 Stock Ref. 105 31 315 T3 105 31 400
More informationRE-PR3-E-27 3-Phase Panel Mount 27kW
Page 1 of 6 RE-PR3-E-27 3-Phase Panel Mount 27kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting
More informationD-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit
D-TECT 2 GJD300 Quad PIR Movement Detector Package Contents Package Contains: 1 x D-Tect 2 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare Sliding Curtains 2
More informationPremier External TD. Installation Manual INS352-3
Premier External TD Installation Manual INS352-3 1. Accessing the Unit 1 2 Remove the top cap and loosen screw (screw retained in wall plate). Push up head unit and remove. 3 Use a flat head screwdriver
More informationRemote NAC Power Supply D7038
Operation and Installation Guide Remote NAC Power Supply D7038 D7038 REMOTE NAC POWER SUPPLY Page 2 2005 Bosch Security Systems Contents Contents 1.0 Overview...5 1.1 Module Control...5 1.1.1 Option Bus
More informationOperation and Maintenance Manual
(FKER Series) Repeater Panel (FKER, FKER, FKER8) Operation and Maintenance Manual Man-9EL Issue June Index Section Page. Introduction.... Safety and mounting.... Technical specification.... Control panel
More informationBX444-Mc Gas Detector
Installation and User Guide Rev.01. BX444-Mc Gas Detector Application Duomo is recognised within the gas industry for providing a comprehensive range of low cost, high reliability gas detection for many
More informationINSTALLATION AND OPERATING INSTRUCTIONS
INSTALLATI AND OPERATING INSTRUCTIS PRODUCTS CMD Series CO Detectors FGD Series Refrigerant Detectors AGD Series Toxic Gas Detectors CGD Series Combustible Gas Detectors (All transmitters are factory set
More informationPERTRONIC INDUSTRIES LTD F4-RMAX Installation Note
Product Overview: The Pertronic F4 Remote LED Mimic / Aux Relay Module F4-RMAX is an optional extra for the Pertronic F4 conventional 4-zone fire alarm panel. This board enables the fire alarm panel to
More informationRevision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual
Revision 1.03 8 November 2013 JVA Technologies Ethernet General Purpose IO Technical Manual www.jva-fence.com.au Table of Contents INTRODUCTION...3 Scope and Purpose...3 Glossary...3 SPECIFICATIONS...4
More informationLUX Hardwired - Installation Notes
Ness LUX wired PIR with Nightlight Quad element pyro sensor 15m x 15m wide angle coverage Look down Creep Zone Selectable Standard and Pet Aware modes Adjustable sensor mask for No Creep and Pet modes
More informationDTS SECURITY P.O.BOX 3399 Base plate-mounting EDENVALE instructions 1610 TELEPHONE
DTS Megashock 5 Energizer 5J (Indoor installation) INSTALLATION MANUAL Comply to: SANS IEC 60 335-2-76 NRCS Ref. no. 7357 10 14 DTS SECURITY P.O.BOX 3399 Base plate-mounting EDENVALE instructions 1610
More informationGeneral Routing Interface
General Routing Interface Features The General Routing Interface Card is an optional module to provide Fire and Fault Routing Outputs compliant with BSEN54-2: 1998 Clauses 7.9 and 8.9 and BS5839-1: 2002.
More informationApplication, Installation, Operation & Maintenance Manual
APPROVED BY:JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL Application, Installation, Operation & Maintenance Manual PAGE 1 of 43 CONTENTS 1. INTRODUCTION... 3 2. GENERAL DESCRIPTION...
More informationConventional Fire Alarm System 2014 V1.2
Conventional Fire Alarm System 2014 V1.2 Product Overview Control Panel 2 Conventional Fire Panel GST102A 2 zone Fire panel GST104A 4 zone Fire panel GST108A 8 zone Fire panel GST116A 16 zone Fire Panel
More informationAQ 100 Series. Arc Flash Protection System
AQ 100 Series Arc Flash Protection System THE CONSEQUENCES OF AN ARC FAULT IN HIGH VOLTAGE SWITCHGEAR THE CONSEQUENCES OF AN ARC FAULT IN OIL-FILLED SWITCHGEAR Arc Phenomena Arc Phenomena Arc fault - facts
More informationAA11 - A SMART SHOCK SENSOR
AA11 - Features of IMPACTOR TM A smart Shock Sensor Normal latching and non-latching setting. Wide dynamic range of sensitivity with High/Low sensitivity settings. Pulse count options, one or two pulses.
More informationREA 105 Arc Protection Module. Operator s Manual
REA 105 1MRS 751005-MUM Issued: 20.04.1998 Version: B2/26.5.2000 Checked: Approved: REA 105 We reserve the right to change data without prior notice. Contents: 1. General...4 1.1. Features...4 2. Safety...5
More informationFor more information, please visit or call toll free at
D-TEK LM Vehicle Loop Detector Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment you are connecting this
More informationIntelligent Security & Fire Ltd
full installation, commissioning and operating manuals can be downloaded from www.haes-systems.co.uk combined addressable / conventional fire alarm control panel User Guide Approved Document No. MFBU-04
More informationOperating Instructions
CS101 CarSense Vehicle Motion Detector Operating Instructions CAUTIONS AND WARNINGS Never use the CS101 as a safety reversing or presence detection system. The CS101 requires that a vehicle be moving for
More informationOperating Instructions
D-TEK Vehicle Loop Detector Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment you are connecting this product
More informationConventional Smoke Detectors KFAPO
Kingfisher Company, inc. Conventional Smoke Detectors KFAPO Features: Wide operating voltage, 9-33 VDC Advanced electronic technology Flashing LED Magnetic test switch Proven detection performance Designed
More information1.4, 2017 JVA ELECTRIC FENCE SYSTEMS
LM4 SECURITY MONITOR Installation and User Manual Edition 1.4, 2017 JVA Z Energizer Range Concept Thank you for choosing our product. The JVA brand is a range of electric fencing products carefully selected
More informationGeneral Purpose IO Technical Manual
General Purpose IO Technical Manual Revision 1.06 8 November 2013 Pakton Technologies PAE222 GPIO Manual.docx Page 1 of 21 Revision 1.06 Last updated 8/11/2013 Table of Contents INTRODUCTION...3 Scope
More informationDEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual
Technical Manual Type EC-2 Engine Control Unit 4189340232D DEIF A/S Technical Manual DEIF A/S Tel.: (+45) 9614 9614 Frisenborgvej 33, DK-7800 Skive Fax: (+45) 9614 9615 Denmark E-mail: deif@deif.com Contents
More informationFlexZone SIX STEPS TO AFFORDABLE PERIMETER PROTECTION EASY TO INSTALL LOW TOTAL COST OF OWNERSHIP HASSLE-FREE OPERATION & MAINTENANCE HOW-TO GUIDE
FlexZone HOW-TO GUIDE SIX STEPS TO AFFORDABLE PERIMETER PROTECTION EASY TO INSTALL LOW TOTAL COST OF OWNERSHIP HASSLE-FREE OPERATION & MAINTENANCE Detect intruders BEFORE they get in By itself, your expensive
More informationOccupancy Sensor LS Descriptions. Product Profile. Technical Specifications
LS-818-3 Descriptions Temco s Passive Infrared Occupancy Sensor is a low cost comercial and residential surface mount occupancy sensor. Advanced filtering reduces false triggering due to air movement and
More informationMD12-1 Vehicle Loop Detector
MD12-1 Vehicle Loop Detector Features Supply 12VDC Adjustable sensitivity (16 levels via a trimpot) 2 x Relay outputs (each can be configured individually) Power up and loop activation LED indicator. Industry
More informationEthernet General Purpose
Ethernet General Purpose Technical Manual Revision 1.03 8 November 2013 Pakton Technologies IO PAE224 Ethernet GPIO Manual.docx Page 1 of 22 Revision 1.03 Last updated 8/11/2013 Table of Contents INTRODUCTION...3
More informationPNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel
PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum
More informationPlease read this sheet as it contains important information
Important Please read this sheet as it contains important information Before commencing installation please familiarise yourself to the equipment by reading the comprehensive installation instructions.
More informationHEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING
-961212-0004 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. ( 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2) Connect
More informationPhotobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide
Photobeam 5000 ISC-FPB-W60QF, ISC-FPB-W0QF, ISC-FPB-W00QF en Installation and Operation Guide Photobeam 5000 Table of Contents en 3 Table of contents Introduction 4. About documentation 4. Bosch Security
More informationD-TEK O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128
O P E R A T I N G I N S T R U C T I O N S D-TEK V E HI C L E L O O P DETECTOR 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com Technical
More informationSENTRY MK2 SOUND LEVEL CONTROL USERS MANUAL
SENTRY MK2 SOUND LEVEL CONTROL USERS MANUAL Sentry MK 2 ENVIRONMENTAL NOISE CONTROL SYSTEM FUNDAMENTALS Noise nuisance legislation requires sound levels to be controlled within limits, for licensed premises
More informationGallagher Perimeter Product Overview
Gallagher Perimeter Product Overview 1 security.gallagher.com Gallagher is a global leader in the innovation, manufacture and delivery of security solutions. Meeting our customers needs inspires us to
More informationThe Remote alarm Panel, TYPE RAPv2
1. Introduction The Remote alarm Panel, TYPE RAPv2 The microprocessor based remote monitor from Metron Eledyne is the latest version of a whole line of successful products, marketed previously under the
More informationNotification Appliance Circuit Module
Notification Appliance Circuit Module D192G en Installation guide Notification Appliance Circuit Module Notices en 3 1 Notices These instructions cover the installation of the D192G Notification Appliance
More informationSANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual
SANDOR QUAD/ESA Double beam Installation And commissioning manual 1 POLITEC s.r.l. Index Main components list Pag. 3 Installation reccomendations Pag. 4 Mounting the bracket Pag. 5 Installation example
More informationHEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING
48ESEP-01 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)
More informationIntegriti - Nemtek Integration Guide
Integriti - Nemtek Integration Guide Integriti - Nemtek Integration The Integriti - Nemtek integration is a powerful TCP/IP based high-level interface which equips the Integriti Security Management System
More informationPerimeter Product Overview. Effective protection for your business
Perimeter Product Overview Effective protection for your business The Gallagher difference Our innovation is driven by the desire to solve problems, meet your needs and provide real business value. We
More informationSENTINEL A - Fault Passage Indicator
SENTINEL A - Fault Passage Indicator AMPEREMETRIC FAULT PASSAGE INDICATORS FOR OVERHEAD MV NETWORKS Installed on poles of overhead lines, the Overhead-Sentinel-A range allows locating the fault arisen
More informationGate Operator. Modfications
Gate Operator Modfications 100va Transformer G90 100 OP1 - Single Phase G90 100 OP3 -Three Phase Upgrades the transformer in the operator enclosure from 40va to 100va. Provides additional control circuit
More informationGas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016
Gas Safety Products Installation, operating and maintenance 05/10/2016 American Gas Safety LLC 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Panel Mounting.... 3 2.2 Mains Supply...
More informationSENTINEL D - Fault Passage Monitoring
SENTINEL D - Fault Passage Monitoring DIRECTIONAL FAULT PASSAGE INDICATORS FOR OVERHEAD MV NETWORKS Installed on poles of overhead lines, the Overhead-Sentinel-D range allows locating the fault arisen
More informationPremier Hazard STC Instructions
PREMIER HAZARD Ltd Bessingby Industrial Estate Bridlington YO16 4SJ Tel: +44 (0) 113 239 1111 Fax: +44 (0) 113 239 1131 www.premierhazard.co.uk info@premierhazard.co.uk Premier Hazard STC Instructions
More informationGas Safety Products. Installation, operating and maintenance 11/26/2015. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1
Gas Safety Products Merlin Gas Detectors Installation, operating and maintenance 11/26/2015 American Gas Safety LLC 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Mounting the Merlin
More informationAL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev
AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 031703 Overview: The Altronix AL802ULADA is an extremely cost effective 8 amp voltage regulated
More informationMODULAR TRACTION SUBSTATIONS CITY ELECTRIC TRANSPORT
CITY ELECTRIC TRANSPORT 2 MODULAR TRACTION SUBSTATION Modular traction substation produced by PrJSC Pluton is an integrated solution for reliable power supply of electric transport catenary. Modular traction
More informationInstallation Guide for models:
140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal3FD - 12VDC @ 4.6 amp or 24VDC @ 5.2 amp. - Sixteen (16) PTC protected power-limited outputs.
More informationInstallation Guide for AL800UL-ADA. NAC Power Extender. Rev
Installation Guide for AL800UL-ADA NAC Power Extender Rev. 090500 Overview: The Altronix AL800UL-ADA is an extremely cost effective 8 amps voltage regulated remote power supply /battery charger. The AL800UL-ADA
More informationORION Mini-Rep INSTALLATION MANUAL
ORION Mini-Rep INSTALLATION MANUAL Orion Mini-Rep - INSTALLATION MANUAL - REVISION 1.0-04/007 The Orion Mini-Rep will provide remote control and system display status from multiple locations to an Orion
More information0$; Installation Instructions. Computerized Control Panel '(6&5,37,21 63(&,),&$7,216 DE5011 1
0$; Computerized Control Panel Installation Instructions '(6&5,37,21 The MAX-5 is a highly reliable, cost effective control panel for residential and commercial applications. Besides being simple to install
More informationOPERATION AND INSTALLATION MANUAL
EX+Plus 2 ZONE, 1AREA EXTINGUISHANT CONTROL PANEL OPERATION AND INSTALLATION MANUAL INTRODUCTION The Premier EX Plus is a 2 zone, single area panel for controlling the release of extinguishing gases in
More informationFratech Multipath-IP STU
Rev 2.41 (September 2008) Installer Manual 1 Fratech Multipath-IP STU P/Nos: Single SIM: 998304OPT/998304TEL Dual SIM: 998307OPT/998307TEL Installer Manual This document contains a product overview, specifications
More informationRota- Spray Instructions (Mega Part & )
Rota- Spray Instructions (Mega Part 500-702 & 500-714) ver. 071604 Please read important unpacking instructions on page 2 1. Carefully consider where the unit will be located. It should be close to any
More informationGas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. Rev: 03 Date:
Gas Safety Products Merlin 1500S Gas Interlock System Installation, operating and maintenance Rev: 03 Date: 08-01-18 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Panel Mounting....
More informationFiber Optic Cable Fence Disturbance Sensor
Architectural & Engineering Specification for Fiber Optic Cable Fence Disturbance Sensor Purpose of document This document is intended to provide performance specifications and operational requirements
More informationSOUNDER CONTROL MODULE SCM-AS4
1 of 9 INTRODUCTION DESCRIPTION The forms part of the Nittan (UK)'s SENSORTEC-ANALOGUE range of Analogue Addressable Devices. This module is designed to control a group of bells or sounders from the detection
More information1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection
Technical Bulletin Arc Fault Monitor 4 Zones, 8 Sensors Features Four independent arc fault tripping zones 1 or 2 arc fault sensors per zone allowing up to 8 arc fault sensors per module Trip indication
More informationSafety Photo Beam UL MONITORED DEVICE
IRB-HB Safety Photo Beam UL325-2010 MONITORED DEVICE Operating Instructions CAUTIONS AND WARNINGS This product is an accessory or part of a system. Always read and follow the manufacturer s instructions
More informationBB TM 508/509 ANTI TWO-BLOCK ALARM SYSTEM HYDRAULIC CRANE INSTALLATION. Greer Company Crane Systems. Greer Company
BB TM 508/509 ANTI TWO-BLOCK ALARM SYSTEM HYDRAULIC CRANE INSTALLATION GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: (714) 259-9702 FAX (714) 259-7626 BB TM 508/509 ANTI TWO-BLOCK ALARM
More informationSecure the other corner. bracket using the remaining screw,
Mount the E-FENCE1 directly to the fabric of the chain link or wire mesh, on the interior side of the protected area as shown in the illustrated examples, at a height of 4 5 feet and 1 foot from a post.
More informationSTANDARD FEATURES SPECIFICATIONS
MAG LOCK P/N 300768 STANDARD FEATURES Holding Force: 1500 lbs.(675 Kg.) Easy Installation: Versatile mounting bracket for new and existing doors and frames. Sensor: Built-in Hall effect crystal affected
More informationAL800ULADA. NAC Power Extender. Installation Guide
AL800ULADA NAC Power Extender Installation Guide Rev. 122000 AL800ULADA - NAC Power Extender Overview: The Altronix AL800ULADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery
More informationThe ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features
990-052, Issue 6 20 March 2006 ID50 Series Single Loop Intelligent Fire Alarm Panels Section: Intelligent Fire Alarm Panels GENERAL The NOTIFIER ID50 series single loop intelligent fire alarm panels, has
More informationDoor Release Power Supply
www.protectingpeople.co.uk Door Release Power Supply Engineer / Installation Manual Document: VI55.1 Protecting People Printed : 04/03/2004-1 - Ventcroft Ltd Door Release Power Supply Engineer / Installation
More informationSensaGuard TM Integrated Latch Installation Instructions
TM Integrated Latch Installation Instructions Certifications IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE Note: Refer to Technical Specifications for Certification information and ratings. 2 TM Installation
More informationSP-1000X. Panic Device Power Controller Installation Guide. Rev
TM SP-1000X Panic Device Power Controller Installation Guide Rev. 120213 Overview: SP-1000X will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed to handle the high current
More informationPower Wave Zone Alarm Panel V8.5. Installation Manual
Power Wave - 8 8 Zone Alarm Panel V8.5 Installation Manual 7 December 2001 Crow (Aust) Electronic Engineering Pty Ltd Corporate Head Office: 429 Nepean Hwy, Brighton East, Vic., 3187 Australia Phone: +61
More information