V-Line Gen2 V2355. Installation Guide
|
|
- Jade Hunter
- 6 years ago
- Views:
Transcription
1 V-Line Gen2 Installation Guide
2 INTRODUCTION The following installation guide has been assembled to assist in planning, installing and wiring of the V-Line Gen2 Fixture. Please read the following instructions carefully prior to installing the fixtures. Should you have any questions or require project consultation, please contact us prior to specifying or installing any i2systems Product. Available Resources In Addition To This Guide Include: Thank you for your purchase of i2systems V-Line Gen2 LED fixture! V-Line Gen2 Datasheet* V-Line Gen2 Instruction Sheet (included with every fixture shipped) LightLink LL-205 Installation Guide* *Available at PS24V75W-E05P / E05PW Datasheet* PS28V350W-E10P / E10PH Datasheet* i2systems Technical Support (9am - 5pm EST) or support@i2systems.com Questions? We are here to help. Call us directly at ELECTRICAL WARNINGS FIXTURE MAINTENANCE All Products must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations. Do not attempt to install or use a Product until you have read and understand the installation instructions and safety labels. Products have risk of shock and no user-serviceable parts. Do not attempt to disassemble the light fixture in any way. Never exceed the maximum voltage rating of the Product. When installing or servicing the Product, be sure to disconnect the power prior to beginning work. Do not make live connections, also known as hot-swapping. Ensure that power to the Product is off before connecting or disconnecting individual units. Maximum plug together for Standard Output (B) is 50 feet of fixtures. Maximum plug together for High Output (A) is 25 feet of fixtures. Refer to installation diagrams included in this manual for additional information. Clean the fixture with mild soap and water only. Ensure that any cleaning products that you use on the optic do not contain plasticizers as they can damage the optic. Do not clean the fixture with high pressure washers or pointed objects as they can damage the Product and cause potential breaches of seals. Do not submerse the Product when cleaning, or allow to sit in standing water. CERTIFICATIONS Pending IP66 1 2
3 V-Line Gen2 Installation Guide When starting any new project, please be sure the following components have been identified. DIMMING COMPONENTS (OPTIONAL) FIXTURE COMPONENTS V-Line Gen2 Specifications: Watts: Input Voltage: Operating Temp: -20 C to 40 C Max Case Temp (Tc): 50 C Humidity: A: 14 Watts / Foot (High Output) B: 7 Watts / Foot (Standard Output) 20-30V DC, 24V DC Nominal 0 to 95% Non-Condensing LightLink LL V Dims up to 5 es using a 0 to 10V Input (sink or source) per IEC 60929:2006 Annex E V AC Input. LightLink LL-205-TRIAC Dims up to 5 es by reading and buffering most any leading and trailing edge incandescent dimmer. 120V AC Input. Both models include onboard dimming buttons with LED bar graph indicator for standalone dimming. MOUNTING BRACKETS Choose 1 of 2 Styles: CONNECTOR ACCESSORIES VLA-13 Adjustable VLA-9 Fixed POWER BOX (REQUIRED) Aluminum adjustable mounting bracket with stainless steel screws. 180 of On-Center Rotation. Aluminum mounting bracket with stainless steel screws. Mates with dovetail slots on Gen2. Dimming Cable (optional) Indoor 1 foot: feet: Outdoor 1 foot: feet: Power s (required) 6 foot power input cable for hard-wire or connection to power box. Power Extension Cables (optional) 1 foot: foot: foot: Power extension cables with dual waterproof plugs. PS24V75W-E05P / E05PW PS28V350W-E10P/E10PH For plugging between power boxes and/or LightLink dimmers. 120V-277V AC Input Powers up to: 5 Feet of A (High Output) 10 Feet of B (Standard Output) E05P Model: Indoor E05PW Model: Outdoor Powers up to: 25 Feet of A (High Output) 50 Feet of B (Standard Output) E10P Model: V AC Input E10PH Model: V AC Input Install Indoors Only. Contact us for outdoor. End-to-End Connector (optional) Connector allows vertical installation and relamping. End Plug (required) One end plug must be installed in last fixture of each run to properly seal the fixture. 3 4
4 V-Line Gen2 Installation Guide CHOOSING AN INSTALLATION SITE When selecting a site for product installation, as with any LED Lighting Product, be sure to keep in mind that at some point the Products may need to be cleaned, repaired, or replaced. Planning ahead for simple product access will assist in reducing headaches down the road. WET LOCATION / OUTDOOR USE Use Only Wet Location Fixtures For Exterior Applications. Any V-Line Gen2 Fixture Marked I Is Indoor Only And Is Not To Be Used For Exterior Applications. TEMPERATURE CONSIDERATIONS Product is rated for an Operating Temperature range of -20 to 40 C with a rated maximum Case Temperature of 50 C. Case Temperature is measured at a test point located in the center of the back side of the Product s extrusion housing. A-26CAB Outdoor Installation Considerations: A-26CAB I Installations that may lead to Case Temperatures above 50 C include: Installing the Product in an area above 40 C ambient temperature. Operating the Product during daylight hours when installed in direct sunlight in hot climates. Installing the Product in a sealed compartment. Installing the Product between panes of glass or directly behind a glass window. Product is rated for exterior applications; however it is not rated for submersible applications and should not be mounted in conditions where there is, or is a possibility of, standing water. Product should not be installed in extreme locations including, but not limited to, those outside of its temperature/humidity ratings and/or applications where Product is subject to water runoff or downspouts. When installing in wet or damp locations, it is good practice to seal all fixtures and junction boxes with electronics-grade RTV silicone sealant to ensure that moisture cannot enter or accumulate in wiring compartments, cables, or other electrical parts. Installing the Product in a tight and/or insulated space. Product should not be installed in applications that exhibit a greater-than-average ambient temperature variation over a short period of time. Examples include those instances where the Product is rapidly heated or cooled at a rate that occurs faster than that typically found in nature. Should you have any concerns about your installation, contact us. Product is equipped with i2systems Active Thermal Management (ATM). In an overheat condition, ATM reduces Product power in order to reduce Case Temperature. However, ATM should not be relied upon as a means of normal operation. Please be sure the Product is operated at or below these specified Operating and Case Temperature levels. Failure to do so will void the warranty. CONNECTION CONSIDERATIONS When installing, ensure all connector plugs are fully seated. Failure to do so may result in intermittent connection, corrosion, and/or leaking into the main housing. Any Product connector that is not used is to be capped with End Plug, model: The End Plug is commonly used at the end of each Product Run and/or on every Product used Standalone (not plugged into another Product). CAUTION: Failure to install the End Plug may result in corrosion and failure of the product. Please be sure your product installation complies with the above guidelines. Failure to do so will void the warranty. 5 6
5 V-Line Gen2 Installation Guide FIXTURE INSTALLATION VLA-13 Adjustable FIXTURE INSTALLATION VLA-9 Fixed.38" [9mm] Space between fixtures End-to-End Plug, model installs through bracket "window"..84" [21mm] Product Installs to bracket via two dovetail strips. Strips slide freely prior to tightening. Be sure to fully tighten during installation..25" [6mm] Tighten screws to secure fixture 1.13" [29mm].75" [19mm] Ø.26" [6mm] 2.68" [68mm].25" [6mm] 1.85" [47mm] 1.33" [34mm] 1.38" [35mm].83" [21mm] 1.50" [38mm] 1.50" [38mm] For standalone installation, use two VLA-13s per Product. For continuous runs, use one VLA-13 per Product, with the exception that the last light in the run requires two. Refer to the diagram above. In installations where there is risk of fixtures falling, install a safety strap to both ends of the fixture. Use a minimum of two VLA-9 Brackets per Product. Three VLA-9s are recommended for 48" units. In installations where there is risk of fixtures falling, install a safety strap to both ends of the fixture. 7 8
6 SYSTEM LAYOUT The diagram below illustrates a basic system installation with dimming installed. For non-dimming installations, the LL-205, dimming cables, and 3rd party dimmer may be omitted V AC input PS24V75W-E05P Use E05 For Short Runs E05P: Indoor E05PW: Outdoor Install End Plug to last light of each run Max Fixture Plug Together: A (High Output) 25 Feet B (Standard Output) 50 Feet AC input* PS28V350W- E10P / E10PH *E10P: V AC E10PH: V AC Max Wire Distance (including V-Line Gen2 Luminaire Lengths and All Cables) A (High Output) 50 Feet B (Standard Output) 100 Feet 3/8 (.375) gap required between fixtures Install End Plug to last light of each run AC input* PS28V350W- E10P / E10PH *E10P: V AC E10PH: V AC 4 Conductor Cable (optional, supplied by others) to be 12awg minimum Use Junction Box (optional, supplied by others) for Remote Runs from X Extension Cable (Specify Length as: -1, -3, or -10) Patent-pending End-to-End Connector allows vertical installation and relamping. Install End Plug to last light of each run Max Distance: 300 Feet to Last Dimming Cable (optional) V AC input (Optional) LL-205 LL V / -TRIAC Dims up to 5 es (Optional) 3rd Party Dimmer TRIAC or 0 to 10V Control Tip on Locating es & Dimmers For best results, be sure to follow maximum distance and load guidelines as outlined in this installation guide. es are typically installed indoors. To install a outdoors, use PS24V75W-E05PW or contact us for additional Wet Location recommendations. All Gen2 power and extension cables may be used indoor / outdoor. Use X Dimming Cable for es installed outdoors. CAUTION: End Plug must be installed to properly seal the fixture. 9 10
7 TYPICAL INSTALLATIONS 100% Intensity, No Dimming with SYNC Option Using PS28V350W-E10P/PH (recommended for longer runs) PS28V350W-E10P/PH HOT/L1* (BLK) AC FEED* NEUTRAL/L2* (WHT) 480W Industrial-Grade UL-Listed Power Supply 15A 28V DC, 350W MAX LED LOAD Optional Dimming Cable *AC Source Connections E10P Model: V AC Input E10PH Model: V AC Input To next (see Tip on Synchronizing es) Using PS24V75W-E05P (recommended for short runs) PS24V75W-E05P* V AC FEED 100W, UL-Listed Class 2 Power Supply 24V DC, 75W MAX Installation Tip: Synchronizing es To sync multiple power boxes at power on, use i2systems Dimming Cable or Up to 5 may be daisy-chained together. Optional Dimming Cable* *When installing the outdoors: - Use PS24V75W-E05PW - Use Dimming Cable To next (see Tip on Synchronizing es) 11 12
8 TYPICAL INSTALLATIONS Wall Mount, Push-Button Dimming Using PS28V350W-E10P/PH (recommended for longer runs) PS28V350W-E10P/PH HOT/L1* (BLK) 15A 28V DC, 350W MAX LED LOAD AC FEED* 480W Industrial-Grade UL-Listed Power Supply NEUTRAL/L2* (WHT) To next *AC Source Connections E10P Model: V AC Input E10PH Model: V AC Input Dimming Cable 120V-277V AC FEED Non-Switched Circuit LL-205* LED bar graph indicator shows selected dim levels Dim Up and Down buttons for Manual Dimming *The following LL-205 Models may be used for push-button dimming: LL-205-S LL V LL-205-TRIAC Operation: To Dim Up, press and hold the right Dim button. Single-tap to return to previous intensity. Double-tap for 100% intensity. To Dim Down, press and hold the left Dim button. Single-tap to turn lights off. The LED bar graph will show selected dim levels. One LL-205 dims up to 5 es. Use i2systems Dimming Cable X or X to daisy-chain es to a single LL-205. WHT Refer to the LL-205 Installation Guide for additional details and technical specifications
9 TYPICAL INSTALLATIONS Wall Mount, Push-Button Dimming Using PS24V75W-E05P (recommended for short runs) PS24V75W-E05P* 24V DC V AC FEED 100W, UL-Listed Class 2 Power Supply **When installing the outdoors: - Use PS24V75W-E05PW - Use Dimming Cable To next Dimming Cable* Operation: 120V-277V AC FEED Non-Switched Circuit LL-205** LED bar graph indicator shows selected dim levels Dim Up and Down buttons for Manual Dimming **The following LL-205 Models may be used for push-button dimming: LL-205-S LL V LL-205-TRIAC To Dim Up, press and hold the right Dim button. Single-tap to return to previous intensity. Double-tap for 100% intensity. To Dim Down, press and hold the left Dim button. Single-tap to turn lights off. The LED bar graph will show selected dim levels. One LL-205 dims up to 5 es. Use i2systems Dimming Cable X or X to daisy-chain es to a single LL-205. Refer to the LL-205 Installation Guide for additional details and technical specifications. WHT 15 16
10 TYPICAL INSTALLATIONS O to 10V Dimming, Sink or Source Using PS28V350W-E10P/PH (recommended for longer runs) PS28V350W-E10P/PH HOT/L1* (BLK) AC FEED* NEUTRAL/L2* (WHT) 480W Industrial-Grade UL-Listed Power Supply 15A 28V DC, 350W MAX LED LOAD To next *AC Source Connections E10P Model: V AC Input E10PH Model: V AC Input Dimming Cable 120V-277V AC FEED Non-Switched Circuit 3rd Party 0 to 10V Dimmer 10V, SINK / SOURCE LL V LED bar graph indicator shows selected dim levels Dim Up and Down buttons for Manual Dimming VIO BRN WHT Operation: LL V reads 0 to 10V levels and translates them to i2systems dimming protocol. Per IEC 60929:2006 Annex E:Less than 1V = OffGreater than 9V = 100% Intensity Between 1V and 9V, intensity will be adjusted on the Gen2 fixture from 1% to 100%. The LED bar graph will display Dim levels based on the 0 to 10V Levels. To manually override the incoming 0 to 10V signal, press either button on the LL V. Manual operation is described on page 14. One LL V dims up to 5 es. Use i2systems Dimming Cable X or X to daisy-chain es to a single LL V. Refer to the LL-205 Installation Guide for additional details and technical specifications
11 TYPICAL INSTALLATIONS O to 10V Dimming, Sink or Source Using PS24V75W-E05P (recommended for short runs) PS24V75W-E05P* V AC FEED 100W, UL-Listed Class 2 Power Supply 24V DC *When installing the outdoors: - Use PS24V75W-E05PW - Use Dimming Cable To next Dimming Cable* 120V-277V AC FEED Non-Switched Circuit 3rd Party 0 to 10V Dimmer LL V LED bar graph indicator shows selected dim levels Dim Up and Down buttons for Manual Dimming 10V, SINK / SOURCE VIO BRN WHT Operation: LL V reads 0 to 10V levels and translates them to i2systems dimming protocol. Per IEC 60929:2006 Annex E: Less than 1V = Off Greater than 9V = 100% Intensity Between 1V and 9V, intensity will be adjusted on the Gen2 fixture from 1% to 100%. The LED bar graph will display Dim levels based on the 0 to 10V Levels. To manually override the incoming 0 to 10V signal, press either button on the LL V. Manual operation is described on page 14. One LL V dims up to 5 es. Use i2systems Dimming Cable X or X to daisy-chain es to a single LL V. Refer to the LL-205 Installation Guide for additional details and technical specifications
12 TYPICAL INSTALLATIONS Leading / Trailing Edge TRIAC Dimming Using PS28V350W-E10P/PH (recommended for longer runs) PS28V350W-E10P/PH HOT/L1* (BLK) AC FEED* NEUTRAL/L2* (WHT) 480W Industrial-Grade UL-Listed Power Supply 15A 28V DC, 350W MAX LED LOAD To next *AC Source Connections E10P Model: V AC Input E10PH Model: V AC Input Dimming Cable 120V AC 60HZ FEED Non-Switched Circuit Dimmer In 3rd Party TRIAC Dimmer Neutral** Dimmer Out LL-205-TRIAC LED bar graph indicator shows selected dim levels Dim Up and Down buttons for Manual Dimming RED WHT RED/WHT **Optional. Only connect AC Neutral to dimmers with a Neutral wire hookup. Refer to the dimmer manual and/or manufacturer for sample wiring diagrams as wiring varies depending on dimmer type and hookup. Operation: LL-205-TRIAC reads the conventional TRIAC dimmer levels and translates them to i2systems dimming protocol. The TRIAC is not loaded, and in most cases a minimum load will not be required. Input may include both Leading and Trailing Edge 120V AC dimmers. Trailing Edge dimmers (those specified as Low Voltage Dimmers) yield best performance. The LED bar graph will display Dim levels based on the interpreted TRIAC levels (results may vary). Most, but not all, TRIAC dimmers will work and some will yield better results than others. Contact us to preapprove the dimmer you've selected for your project. One LL-205-TRIAC dims up to 5 es. Use i2systems Dimming Cable X or X to daisy-chain es to a single LL-205-TRIAC. Refer to the LL-205 Installation Guide for additional details and technical specifications
13 TYPICAL INSTALLATIONS Leading / Trailing Edge TRIAC Dimming Using PS24V75W-E05P (recommended for short runs) PS24V75W-E05P* V AC FEED 100W, UL-Listed Class 2 Power Supply 24V DC *When installing the outdoors: - Use PS24V75W-E05PW - Use Dimming Cable To next Dimming Cable* 120V AC 60HZ FEED Non-Switched Circuit Dimmer In 3rd Party TRIAC Dimmer Neutral** Dimmer Out LL-205-TRIAC LED bar graph indicator shows selected dim levels Dim Up and Down buttons for Manual Dimming RED WHT RED/WHT **Optional. Only connect AC Neutral to dimmers with a Neutral wire hookup. Refer to the dimmer manual and/or manufacturer for sample wiring diagrams as wiring varies depending on dimmer type and hookup. Operation: LL-205-TRIAC reads the conventional TRIAC dimmer levels and translates them to i2systems dimming protocol. The TRIAC is not loaded, and in most cases a minimum load will not be required. Input may include both Leading and Trailing Edge 120V AC dimmers. Trailing Edge dimmers (those specified as Low Voltage Dimmers) yield best performance. The LED bar graph will display Dim levels based on the interpreted TRIAC levels (results may vary). Most, but not all, TRIAC dimmers will work and some will yield better results than others. Contact us to preapprove the dimmer you've selected for your project. One LL-205-TRIAC dims up to 5 es. Use i2systems Dimming Cable X or X to daisy-chain es to a single LL-205-TRIAC. Refer to the LL-205 Installation Guide for additional details and technical specifications
14 V-Line Gen2 Installation Guide FREQUENTLY ASKED QUESTIONS LIMITED WARRANTY Basic Installation Q: Can I connect the Gen2 directly to line voltage? A: No. Connecting the Gen2 directly to line voltage or any voltage higher than 30V DC will damage the fixture and void the warranty. Use an i2systems to convert line voltage to low voltage. Q: I see the Gen2 is rated from 20-30V DC. Will the intensity vary over the voltage range? A: No. The light output will remain constant over the full range. Based on the Gen2 s constant power design, as the voltage drops, the current will increase proportionally (conversely, it will go down as the voltage rises), adding additional current load in the wiring and on the. Q: Can I load the to the full wattage specified (i.e. 75W or 350W)? A: Yes. The power supplies installed in i2systems es are derated (i.e. a 75W uses a 100W Power Supply). Refer to the Datasheet for additional details. Q: Can I use a 3rd party low voltage power supply? A: While it is possible to use a 3rd party 24V DC power source, we highly discourage this and doing so may void the Gen2's warranty. Not all power supplies exhibit the same characteristics and there is the possibility of the power supply being incompatible or causing damage to the Gen2 fixture. Dimming-Related Q: For installations without dimming, what do I do with the orange and violet wires on the Gen2? A: The orange and violet wires on the Gen2 are for isolated dimming control. These wires are optically isolated to the Gen2 power and may be cut and capped using best industry practices. Alternatively, tie all orange wires to orange wires and violet wires to violet wires to synchronize light turn-on when power is applied. Refer to the diagram on page 11. Q: Is the LightLink LL-205 limited to dimming 5 es? A: No. The LightLink LL-205 is capable of dimming more than 5 es. Please refer to the LL-205 Installation Guide for additional details. Q: When using the LightLink LL-205 Dimming Module, do I need a 3rd Party Dimmer? A: No. The LL-205 is often used as a standalone dimmer. This feature is useful for simple installations and/or troubleshooting dimming installations where the LightLink is able to override the incoming dimming signal to help pinpoint the problem. Q: Can I mix and match i2systems Product series on the same LightLink dimmer? A: Yes. However, contact us prior to doing so, as results may vary, depending on the Product. 1.1 Limited Warranty. Products are warranted to be free from defects in material and workmanship and to conform substantially to Seller s then-current (as of the date of Product shipment) user documentation and specifications for a period of three (3) years from the date of invoice (the Warranty Period ), provided the Products are used under those operating conditions (including electrical values and environmental conditions) described in Seller s then-current user documentation and specifications for such Products. Seller shall not be liable under the foregoing warranty if Buyer fails to provide Seller with notice of the alleged defect during the Warranty Period. 1.2 Remedies. In the event a Product does not comply with the foregoing express warranty, Buyer may notify Seller within the Warranty Period and if so notified Seller will, at Seller s option: (a) provide a replacement for such Product or defective component or part thereof that has caused the warranty claim (such Product or defective component or part thereof that has caused the warranty claim, the Warranty Item ); or (b) refund to Seller the lesser of (1) the amount Seller paid for the Warranty Item, and (2) Seller s cost to replace the Warranty Item, in each case as determined by Seller in its sole and absolute discretion following receipt and inspection by Seller of the Warranty Item. For the avoidance of doubt, provided a replacement for such Product or defective component or part thereof expressly does not include any removal or reinstallation costs or expenses, including without limitation labor costs or expenses. All exchanged Warranty Items shall become the property of Seller. Seller may use either new or remanufactured, reconditioned or refurbished components or parts (if in like-new condition), or functionally equivalent components or parts, in the furnishing of replacement(s) for any Warranty Item. Seller s warranty flows only to Buyer of the products. If the Seller chooses to replace the Product and is not able to do so because it has been discontinued or is not available, the Seller may replace it with a comparable product. 1.3 Limitations. The foregoing warranty is limited, and does not extend to, and Seller shall incur no liability for: (a) lumen maintenance of the Products; (b) color shift of light output of the Products; (c) degradation or discoloration of the Product housing(s); (d) mechanical or cosmetic deterioration of the Products associated with normal wear and tear. For clarity and without limiting the generality of the foregoing, the foregoing warranty does not apply if a Product s light module continuously generates light at any intensity, regardless of whether such intensity has decreased since the date of first use of such Product [(viz., warranty coverage only applies in the event that such light module generates no light or generates light intermittently)]. This limited warranty only applies when the product has been properly wired and installed and operated within the electrical values, operating range and environmental conditions provided in the Specifications. This warranty does not apply to damage or failure to perform arising as a result of any Acts of God or from any abuse, misuse, abnormal use or use in violation of any applicable standard, code, or instructions for use including those contained in the latest National Electrical Code, the Standards for Safety of Underwriters Laboratory, Inc., the Standards for the American National Standards Institute or, in Canada, the Canadian Standards Association. This Warranty shall become void in the event any repairs or alternations not duly authorized by the Seller in writing are made to the Product by any person. Buyer shall convey with each Product distributed to end users this LIMITED WARRANTY, and if Seller determines that the appropriate remedy for a defective product is refund of Buyer s purchase price, Buyer shall refund to the end user (or arrange for the refund to the end user of) the full purchase price paid by the end user for such defective Product. With respect to Products sold to the Buyer by Seller but not bearing the Seller s name or sub-brand name, SELLER MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, but will make available to the Buyer upon request but only to the extent permitted by law and relevant contracts, the warranties of the manufacturer of the relevant product. 1.4 Exclusions; Buyer Indemnification. The foregoing warranty shall be void with respect to defective conditions or non-conformities of the Products resulting from: (a) modifications of Products not authorized by Seller; (b) misuse, neglect, accident or abuse, improper wiring, repairing, splicing, alteration, installation, storage or maintenance; (c) use in a manner not in accordance with Seller s published operating specifications or instructions for the applicable Products; (d) Product defects caused by Buyer s combination of the Products with equipment provided or manufactured by third party vendors (unless Seller is advised, in writing, of such proposed combination and Seller thereafter consents in writing to such combination); (e) breach by Buyer or its employees, partners to whom Buyer sold Product, contractors, representatives, agents or affiliates, (collectively, Buyer Parties ) of any obligation herein; or (f) negligent use, application, installation or implementation of Product by any of the Buyer Parties. Buyer shall indemnify, defend and hold harmless Seller and its officers, directors, agents, employees, affiliates, representatives, successors, and assigns from and against all losses, liabilities, costs, and expenses (including, without limitation, attorneys fees) arising out of out of or in connection with claims by third parties for any loss, damage, or injury (including death) caused by or alleged to be caused by the circumstances described in this Section 5.4. Buyer shall not join, settle or otherwise attempt to affect or dispose of any such claim without Seller s written consent. 1.5 DISCLAIMER. THE EXPRESS WARRANTIES IN THIS SECTION ARE THE ONLY WARRANTIES GRANTED BY SELLER AND THE REMEDIES IN THIS SECTION 5 ARE THE SOLE AND EXCLUSIVE REMEDIES FOR BREACH OF SUCH WARRANTIES. EXCEPT AS EXPRESSLY PROVIDED IN THIS SECTION 1, SELLER MAKES NO OTHER WARRANTIES, EXPRESS, IMPLIED OR STATUTORY, AND SELLER EXPRESSLY DISCLAIMS ALL SUCH OTHER WARRANTIES, INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF QUALITY, CONDITION, TITLE, MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT. No agent, employee, or representative of Seller has any authority to bind Seller to any affirmation, representation or warranty concerning goods sold by Seller and unless an affirmation, representation or warranty is specifically included herein or in Seller s sales acknowledgement, it does not form a part of the basis of any bargain between Seller and Buyer and shall not be enforceable by Buyer. For i2systems complete Terms & Conditions of Sale, please visit our website at B 25 26
15
V-Line Gen3 V3285. Installation Guide
V-Line Gen3 Installation Guide V-Line Gen3 Installation Guide INTRODUCTION The following installation guide has been assembled to assist in planning, installing and wiring of the V-Line Gen3 Fixture. Please
More informationV-Line Gen4 V4295. Installation Guide
V-Line Gen4 V4295 Installation Guide Thank you for purchasing the V-Line Gen4 LED Fixture! 1 Support If you have questions after reading this information or would like our advice on your project, call
More informationV-Line Gen3 V3285. Installation Guide
V-Line Gen3 V3285 Installation Guide Thank you for purchasing the V-Line Gen3 LED Fixture! 1 Support If you have questions after reading this information or would like our advice on your project, call
More informationV-Line Gen3 V3285. Installation Guide
V-Line Gen3 V3285 Installation Guide Thank you for purchasing the V-Line Gen3 LED Fixture! 1 Support If you have questions after reading this information or would like our advice on your project, call
More informationMaxLite LED VAPOR TIGHT LINEAR FIXTURES
A cost effective LED Vapor Tight Fixture features a full length polycarbonate lens and a one-piece white glass reinforced polyester (GRP) body. Designed to meet or exceed seven to 10 foot-candles at 8
More informationMaxLite LED High Bay Fixtures
General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More informationMaxLite LED MICRO-T PANEL
` Installation Instructions General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all
More informationMaxLite Polygon Linear LED Light
General Safety Information For Contractors: WARNING: Light fixtures should only be installed by qualified electricians. Be sure to use proper mounting method and hardware rated for the weight of the light
More informationMaxLite LED Vapor Tight Linear Fixture
General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More informationMaxLite LED Round Pendant Highbay Series
General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More informationSeries: MBC1-TC Mini Benchtop Temperature Controller
User s Guide Series: MBC1-TC Mini Benchtop Temperature Controller Imagine Instruments LLC:: 4500 Williams Drive, Ste 212-318 :: Georgetown, TX 78633 :: p. 855.574.6243 e-mail: info@imagineinstruments.com
More informationInstallation and Maintenance Instructions
Installation and Maintenance Instructions AMERIVENT GAS RELINING KITS MODEL AFL This symbol on the product means the product is listed by Underwriters Laboratories, Inc. GENERAL INSTALLATION GUIDELINES
More informationIN-GROUND SUBWOOFER INSTRUCTION MANUAL LS12T SUB LS15T SUB
IN-GROUND SUBWOOFER INSTRUCTION MANUAL LS12T SUB LS15T SUB Introduction Thank you for purchasing a SLS Subwoofer. When properly installed, this subwoofer will provide you with years of outdoor entertainment
More informationOPERATION & INSTALLATION MANUAL
OPERATION & INSTALLATION MANUAL Model: SIO 14 & SIO 18 Electric Tankless Hot Water Generators Table of Contents SAFETY INFORMATION... 1 INTRODUCTION... 2 Unit Operation:... 2 Unit Freezing:... 3 Maintenance:...
More informationINSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM
INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM D-tect Systems 11814 South Election Road, Suite 200 Draper, UT 84020 www.dtectsystems.com 1 Introduction The mini
More informationUse this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30
273 Branchport Avenue Long Branch, N.J. 07740 (800) 631-2148 Thank you for using our products. www.wheelockinc. com INSTALLATION INSTRUCTIONS HORN SPEAKER WITH MULTI-TAP TRANSFORMER Use this product according
More informationINSTRUCTION MANUAL HS-229G
INSTRUCTION MANUAL HS-229G 510977 STEP 1 - Where to Install the Thermostatic Steam Trap Determine where to install the thermostatic steam trap based on the following information. a. The trap should be
More informationInstallation, Operation & Service Manual
Installation, Operation & Service Manual WARNING Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the Installation, Operation and
More informationOCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters
1200 North Main Street Fostoria, OH 44830 Phone: 800-495-4525 Fax: 419-435-0842 A DIVISION OF www.fostoriaindustries.com OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters *EXCLUDING
More informationModel 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 9001EXP Alarm No. 2080203(24)
More information- User Brochure Programmable Thermostat 510
- User Brochure Programmable Thermostat 510 U 510 09/09 Congratulations on the purchase of your tekmar programmable thermostat. This thermostat combines easy-to-use programming with advanced features to
More informationInstallation & Operation Manual
Humidity & Temperature Sensor 086 Accessories 086_D 08/12 Replaces: New Installation & Operation Manual Introduction The Humidity & Temperature Sensor 086 can be connected to select tekmar thermostats
More informationMaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights
General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More informationMODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET
FOOD WARMING/ MERCHANDISING CABINET MODEL 925W This warmer/merchandiser provides heated circulating air to keep foods fresh and evenly warmed. It is constructed of stainless steel and tempered glass for
More informationCD6102 / CD6102 OC / CD6102-2
PreView Display CD6102 / CD6102 OC / CD6102-2 Operating Manual www.previewradar.com PATENTS Patented under one or more of the following U.S. Patents: 5345471, 5523760, 5457394, 5465094, 5512834, 5521600,
More informationIon Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm
Ion Endeavor Controller Digital Level Control with Alternation Page 1 of 8 General Overview The Ion Endeavor is a pump controller that senses a water level of up to 72", has a configurable water level/pump
More informationAppearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.
Infrared Thermosensor CSM DS_E_3_2 Achieve Low-cost Measurements with an Infrared Thermosensor. The has an electromotive output as high as that of a thermocouple, thus connecting directly to the thermocouple
More informationUSE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle
USE AND CARE GUIDE FOR MODEL MEK1, MEK15 Express Cordless Kettle IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed, including the following: 1. Read
More informationMODEL (Single Door) MODEL (2 Door pass through)
FOOD WARMING/MERCHANDISING CABINET MODEL 680-1 (Single Door) MODEL 680-2 (2 Door pass through) This warmer provides bottom heat to keep crusts crisp. The illuminated shelves are thermostatically controlled
More informationFloorHeat Installation Manual
FloorHeat Installation Manual Transforming frosty floor surfaces into radiant warmth Transforming frosty floor surfaces into radiant warmth Contents Important Instructions!... 3 Safety Instructions:...
More informationELECTRICAL DATA: FEATURES: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET. 15 Width 7 Width
FOOD WARMING/ MERCHANDISING CABINET MODEL 323HH MODEL 323HH-7 15 Width 7 Width With the ability to hold a point-of-purchase advertisement, these sleek, compact warmers are sure to draw eye catching attention.
More information- User Brochure tekmarnet 4 Setpoint Control 161
- User Brochure tekmarnet 4 Setpoint Control 161 U 161 08/07 Congratulations on the purchase of your tekmar setpoint control with communication. The setpoint control combines easy-to-use programming with
More informationLED RETROFIT CONVERSION KITS
Engineered Products Company s LED RetroFit Conversion Kits convert older 4-foot and 8-foot T8 or T12 strip-type fixtures into energy efficient LED luminaires. High quality components and attractive design
More informationBACKUP BATTERY INSTALLATION INSTRUCTIONS
www.tiltlights.com BACKUP INSTRUCTIONS A Lauren International Company www.laurenillumination.com 855 440 8458 LdPE7-2014 SELf-TESTINg EmERgENCY LEd driver RATINGS: Input: 100-277 VAC 50 or 60 Hz Output:
More informationDuct Mount. Installation Instructions
Duct Mount Installation Instructions 00809-0600-4975 Legal Notice The Flame Detector described in this document is the property of Rosemount. No part of the hardware, software, or documentation may be
More informationSFH136-CN TRUSTED FOR OVER 100 YEARS. Sunbeam Heater. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS
TRUSTED FOR OVER 100 YEARS SFH136-CN Sunbeam Heater Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS When using electrical
More informationES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor
Humidity Sensor Temperature/Humidity Sensor ES2-THB CSM ES2-THB_DS_E_3_2 Detect Humidity within an Accuracy of ±3% in a Compact Body. Set Provides Superior Humidity Control and Temperature/ Humidity Control.
More informationinstallation, operation & Maintenance manual Floor-mounted Induction units
installation, operation & Maintenance manual Floor-mounted Induction units built on innovation induction units- fmfby/ fmlby/ fmtby Floor-mounted induction units FMFBY, FMLBY, & FMTBY are designed for
More informationA PROUD HERITAGE OF EXPERIENCE & QUALITY. Beverage Cooler VT-SC-1
A PROUD HERITAGE OF EXPERIENCE & QUALITY Beverage Cooler VT-SC-1 O W N E R S M A N U A L W W W. V I N O T E M P. C O M Your Beverage Cooler This unit can be used for Storage and/or Service. The cooler
More informationXT Series Thermostats
ISO 9001 Explosion-Proof & Moisture Resistant XT Series Thermostats Installation, Operation, & Maintenance Instructions XTWA Thermostat XTWL Thermostat XTB Thermostat Part No.MI133.Rev.2.00 Date of Issue:
More informationIrene-H READ AND SAVE THESE INSTRUCTIONS
Irene-H 60", 52" or 42" CEILING FAN READ AND SAVE THESE INSTRUCTIONS Irene-3H Irene-5H QUICK ASSEMBLY NOTES: * Do not wire in fan while house wires are Live. Turn power off at breaker before installation
More information48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual
8 Vanguard Belt Drive Fans Installation and Operators Instruction Manual Thank You The employees of Chore-Time Equipment would like to thank your for your recent Chore-Time purchase. If a problem should
More information10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!
10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX 77041-4051 VOICE (713) 973-6905 FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN
More informationSilicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual
Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual Read and understand this material before operating or servicing these heating tapes. Failure to understand
More informationELSTON 52 CEILING FAN
ELSTON 52 CEILING FAN MODEL #10290 Español p. 21 Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883, Monday - Thursday, 8 am -
More informationOWNERS MANUAL MODEL EXTERMINATOR VS900 C/R BLACK VAPOR CLEANING SYSTEM SAFETY INSTRUCTIONS OPERATIONS CARE AND MAINTENANCE TROUBLESHOOTING WARRANTY
OWNERS MANUAL MODEL EXTERMINATOR VS900 C/R BLACK VAPOR CLEANING SYSTEM SAFETY INSTRUCTIONS OPERATIONS CARE AND MAINTENANCE TROUBLESHOOTING WARRANTY BEFORE USING THIS VAPOR CLEANING SYSTEM READ THESE INSTRUCTIONS
More informationSOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual
SOLARHOT SuperVox Installation/ Owner s Manual Description / Applications System Overview The SOLARHOT SuperVox solar thermal glycol system. The SuperVox allows for easy installation of large solar water
More informationAir Pump Up to 800 gallons
Air Pump Up to 800 gallons REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. PACKAGE CONTENTS ITEM #PBPAPK40W Questions, problems, missing parts? Before returning to your retailer, call our customer
More informationInstallation and Owner Man u al
T H R E E P H A S E Evaporator Fan Control System Installation and Owner Man u al WARNING The installation of this device should be done only by competent personnel, experienced in electrical wiring, and
More informationChanging the Light Bulb The light bulb is located behind the Temperature control. IMPORTANT: Depending on your model, the light bulb in your new refrigerator may use LED technology. If your model uses
More informationHotPoly Tote Tank / IBC Heaters (TTH Series)
HotPoly Tote Tank / IBC Heaters (TTH Series) Instruction Manual Read and understand this material before operating or servicing these heaters. Failure to understand how to safely operate these heaters
More informationTAILORED S PECTRUM. Commercial Grow Luminaire SQRT670CX1 INSTRUCTION MANUAL
TAILORED S PECTRUM Commercial Grow Luminaire SQRT670CX1 INSTRUCTION MANUAL THANK YOU Thank you for purchasing Sunmaster s SQRT670CX1, spectrally tailored for indoor growing. This state-of-the art fixture
More informationDISCONTINUED VERSION The information in this manual is no longer current. OPERATING & SERVICE MANUAL
BUNN HC-1 HC-2 HC-3 DISCONTINUED VERSION The information in this manual is no longer current. OPERATING & SERVICE MANUAL BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE:
More informationOKB, OKD, & OKH Series
ISO 9001 Infrared Radiant Heaters OKB, OKD, & OKH Series Installation, Operation, Maintenance Instructions & Spare Parts CE Certified HIGH TEMPERATURE, RISK OF FIRE, FIRE/EXPLOSION HAZARD. During operation,
More informationMN908 No. 282C Replaces 282B LB7013
No. 282C Replaces 282B LB7013 Instruction Manual For Baldor Dust Control Units Models DC7, DC7 3, DC8, DC8 3, DC10, DC10 3, DC12, DC12 3 and DC14 3. For use on Grinders mounted to GA16 and GA20 pedestals
More informationion Genesis Pump Controller
High Water Alarm Document No.: IONG_OM Page 1 of 7 Table of Contents Safety Precautions.......................... 1 General Overview.......................... 1 Installation.................................2
More informationIon Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm
Page 1 of 8 General Overview Thank you for purchasing an Ion Genesis controller. Take the time to read the instructions carefully before using this appliance. We strongly recommend that you keep this instruction
More informationLED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS
LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE ITM. / ART. 1165831 Model: LM56123 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY For assistance with assembly or installation,
More information48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual
8 Vanguard Belt Drive Fans Installation and Operators Instruction Manual Thank You The employees of Chore-Time Equipment would like to thank your for your recent Chore-Time purchase. If a problem should
More informationModel AV1LED Audio-Visual LED Light Installation and Maintenance Manual
Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual 2561528A REV. A 810 Printed in U.S.A. Warranty Seller warrants all goods for five years on parts and 2-1/2 years on labor, under
More informationFigure 1. Figure 2. See notes 1 and 2 below.
273 Branchport Avenue Long Branch, N.J. 07740 (800) 631-2148 Thank you for using our products. www.wheelockinc. com INSTALLATION INSTRUCTIONS HORN SPEAKER WITH AMPLIFIER Use this product according to this
More informationPressurized Filter Up to 1250 gallons
Pressurized Filter Up to 1250 gallons REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. ITEM #FP1250UV Questions, problems, missing parts? Before returning to your retailer, call our customer service
More informationTrueClean ToteCleaner
TrueClean ToteCleaner Installation, Operation, and Maintenance Manual www.trueclean.us TrueClean Check Valve Table of Contents Introduction.... 1 About... 1 Warranty... 2 Safety... 3 Important Safety Information....
More informationAMERICA AMERICA 52 CEILING FAN INSTALLATION AND OPERATION MANUAL
AMERICA AMERICA 52 CEILING FAN INSTALLATION AND OPERATION MANUAL Ceiling Fan Weight Including Accessories: 21.00 Lbs. READ AND SAVE THESE INSTRUCTIONS TABLE OF CONTENTS Tools and Materials Required...
More informationInstallation & Operation Manual
Installation & Operation Manual Radiant Thermostat 519 519_D 06/16 Zoning Replaces: 03/13 Introduction The Radiant Thermostat 519 accurately controls the room and/or floor temperature for a hydronic heating
More informationUser s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access
II User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access Part #2139703 Rev. G II Table of Contents Introduction...3 Elevator Overview...4 Description of Features...5-7
More informationWrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)
Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series) Instruction Manual Read and understand this material before operating or servicing these heating tapes. Failure to understand how to safely operate
More informationMODEL HDM-4 AND HDM-6 PERFECT HOLD DELI CASE INSTALLATION/OPERATION MANUAL
An American Tradition Since 1954! MODEL HDM-4 AND HDM-6 PERFECT HOLD DELI CASE INSTALLATION/OPERATION MANUAL Be sure ALL installers read, understand, and have access to this manual at all times. Broaster,
More informationHere is what comes in your box:
Here is what comes in your box: We recommend that you pull everything out of the box and lay it out. We have grouped the drawn components below with the hardware you ll need for those parts. The screws
More informationEliza-H 56 CEILING FAN
Eliza-H 56 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. 60Hz Please do not use any electric or battery powered tools in the assembly and installation of this or any Matthews Fan Company
More informationinstallation, operation & Maintenance manual Floor-mounted Induction units acb 30/35
installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35 built on innovation acb 30 & 35 Active Chilled Beam Models ACB30 & ACB35 are designed for installation in the ceiling
More informationLETTER FROM THE FOUNDERS
LETTER FROM THE FOUNDERS We sleep for one third of our life. Assuming we live 75 years, that s 25 years asleep. This is the time when we recharge our bodies to take on the next day, and refuel our brains
More informationIRENE-HLK 60", 52" or 42" CEILING FAN
IRENE-HLK 60", 52" or 42" CEILING FAN READ AND SAVE THESE INSTRUCTIONS IRENE-3HLK IRENE-5HLK QUICK ASSEMBLY NOTES: * Do not wire in fan while house wires are Live. Turn power off at breaker before installation
More informationModel 400 Series Lights Installation Instructions
Model 400 Series Lights Installation Instructions 256A424G REV. A 610 Printed in U.S.A. Warranty Seller warrants all goods for five years on parts and 2-1/2 years on labor, under the following conditions
More informationDUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION
DUVAL 52 CEILING FAN MODELS #50201, 50206 Español p. 19 LISTED FOR DAMP LOCATION Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883,
More informationEliza Hugger 56 CEILING FAN
Eliza Hugger 56 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. 60Hz Please do not use any electric or battery powered tools in the assembly and installation of this or any Matthews Fan
More informationCOMMERCIAL REFRIGERATOR INSTRUCTION MANUAL
COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL Model No.: TGM-69R FEATURE CHART ADVERTISING PANEL FLOURESCENT SWITCH COOLING FAN FLOURESCENT LAMP EVAPORATOR INNER DRAIN PAN SHELF DOOR HANDLE GLASS DOOR CONDENSER
More informationLV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories
LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories Operating & Instruction Manual 1475 Lakeside Drive Waukegan, Illinois 60085 U.S.A. 847.473.4980
More informationBX Series. Installation, Operation, Maintenance Instructions & Spare Parts
ISO 9001 BX Series Installation, Operation, Maintenance Instructions & Spare Parts WARNING WARNING. The BX convection heater is a heavy duty baseboard designed for use in industrial environments and is
More informationIAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide
Installation Manual and Owner s Guide IAQ Series Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application PCOB-09012-0--A - 9" PCO BULB PCOB-14024-0--A - 14" PCO BULB 67202220344 Revised 07-12
More informationAA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL
AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL Table of Contents Introduction 3 Incoming Inspection 3 General Safety & Warnings 3 Technical Specifications 4 Installation and Operation Instructions
More information(HSTAT Series) Instruction Manual
Silicone Rubber Heating Tapes with Adjustable Thermostat Control (HSTAT Series) Instruction Manual Read and understand this material before operating or servicing these heating tapes. Failure to understand
More informationGASGUARD LEL 3 OPERATING & INSTALLATION MANUAL
GASGUARD LEL 3 Ammonia Sensor OPERATING & INSTALLATION MANUAL GasGuard LEL 3 Operating and Installation Manual 2 Table of Contents 3GasGuard LEL Operating and Instruction Manual General description. 4
More informationTrueClean ToteCleaner
TrueClean ToteCleaner Installation, Operation, and Maintenance Manual www.trueclean.us TrueClean Check Valve Table of Contents Introduction.... 1 About... 1 Warranty... 2 Safety... 3 Important Safety Information....
More information52 CEILING FAN. Owner s Manual Models #50336, 50337
52 CEILING FAN Owner s Manual Models #50336, 50337 If a problem cannot be remedied or you are experiencing difficulty in installation, please contact the Service Department: 1-877-706-3267, 9 a.m.- 5 p.m.
More informationGlass Door Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!
Turbo Air Speed up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Glass Door Merchandiser Installation and Operation Manual Please read this manual completely
More informationSUTTON 52 CEILING FAN
SUTTON 52 CEILING FAN MODELS #50188, 50189, 50190 Español p. 19 Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883, Monday - Thursday,
More informationPatent Pending invent for New Construction
Patent Pending invent for New Construction Users Manual 3.0 2 Introduction Your new invent for New Construction manual register is an energy saving and comfort enhancing device. The unit works by replacing
More informationMODEL 620 ELECTRICAL DATA: FEATURES: DIMENSIONS: SHIPPING INFORMATION: AVAILABLE ACCESSORIES: CONVECTION OVEN 1/4 SIZE PAN
CONVECTION OVEN 1/4 SIZE PAN MODEL 620 Convection is the ideal way to cook convenience foods and this compact oven can bake it all. Heated, circulating air throughout the oven penetrates food quickly.
More informationEliza HLK 56 CEILING FAN READ AND SAVE THESE INSTRUCTIONS
Eliza HLK 56 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. 60Hz For Damp Location QUICK ASSEMBLY NOTES: * Do not wire in fan while house wires are Live. Turn power off at breaker before
More informationHawkins 44 in Ceiling Fan Owner s Manual. Hawkins Ventilador de Techo de 1,12 m Manual del Propietario
117 391 Hawkins 44 in Ceiling Fan Owner s Manual Hawkins Ventilador de Techo de 1,12 m Manual del Propietario 44 Hawkins Ceiling Fan by Hampton Bay Thank you for purchasing our ceiling fan. This product
More information16" and 20" Economy Incandescent Full Hoods Owner s Manual
16" and 20" Economy Incandescent Full Hoods Owner s Manual Central Aquatics 5401 West Oakwood Park Drive Franklin, WI 53132 May 2015 Aquarium Reflector Model 16" New Economy Incandescent fits 5-1/2 Aquariums.
More informationInstallation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5
Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5 Solar Mounting Solutions UNI-SA/21.5 March 2009 www.ironridge.com 2009 IronRidge, Inc. All Rights Reserved Version 2.0 2 Universal
More informationInstallation and Operating Guide Document No Vacuum Chambers Copyright 2017 Terra Universal Inc. All rights reserved.
Document No. 1800-60 Copyright 2017 Terra Universal Inc. All rights reserved. Revised June 2017 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX:
More informationOPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS
Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump Page 1 of 8 biohazard risk exists. Installer(s) and/or service personnel must use proper Personal Protective Equipment and follow handling procedures
More informationUser s Manual and Operating Instructions
User s Manual and Operating Instructions Model Numbers: CL-36-BDF-A, CL-42-BDF-A, CL-48-BDF-A READ AND SAVE THESE INSTRUCTIONS IMPORTANT: Read and understand all of the directions in this manual before
More informationUSE & CARE INSTRUCTIONS 10- SPEED HAND MIXER FSHM100
SPECIAL SELECT USE & CARE INSTRUCTIONS 10- SPEED HAND MIXER FSHM100 IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed, including the following: 1.
More informationDUST FREE CARBON Whole House Air Purifier
DUST FREE CARBON Whole House Air Purifier Installation & Operation Manual This manual covers the following model: DF CARBON 14" - #13052 GENERAL This device is designed to be installed into an existing
More informationINSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER
273 Branchport Avenue Long Branch, N.J. 07740 (908) 222-6880 INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER GENERAL: The Series PA-250 and PA-500 Watt Booster Amplifiers are designed
More informationRoanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario
160 854 Roanoke 48 in Ceiling Fan Owner s Manual Roanoke Ventilador de Techo de 1,22 m Manual del Propietario 48 Roanoke Ceiling Fan by Hampton Bay Thank you for purchasing our ceiling fan. This product
More information