Marine Fire Protection. Kidde Residential and Commercial Division 1394 South Third Street, Mebane, NC Tel

Size: px
Start display at page:

Download "Marine Fire Protection. Kidde Residential and Commercial Division 1394 South Third Street, Mebane, NC Tel"

Transcription

1 Marine Fire Protection 1

2 D I S P O S A B L E FIRE EXTINGUISHER Marine 210D MPWC Fire Extinguisher Part number 43 Regular use UL Rated 5-B:C Suitable for use on Class B (liquids & gases) and Class The PWC unit is fitted with a one touch pressure check device to ensure reliable performance. It is manufactured from bilingual nameplate Pressure check device to determine fire s readiness status Easy-to-pull safety clip 2.0 lb of fire extinguishing 2 year limited warranty UL approved Model MPWC Regular Dry Chemical UL rated 5-B:C Sodium Bicarbonate 2 year limited warranty Suitable for use on liquid & energized electrical fires 2.0 lb 3.1 lb 2.9 inches inches 8-10 seconds feet UPC:

3 FIRE EXTINGUISHER Mariner 10 Fire Extinguisher Part number 428 Regular use UL Rated 10-B:C D I S P O S A B L E Suitable for use on Class B (liquids & gases) and Class The Mariner 10 unit is fitted with a pressure gauge that provides at-a-glance status, is manufactured from bilingual nameplate fire is charged 2.9 lb of fire extinguishing UL approved strap retention supplied mounting Model Mariner 10 Regular Dry Chemical UL rated 10-B:C U.S.C.G, DOT approved Supplied with retention strap Sodium Bicarbonate Suitable for use on liquid & energized electrical fires 2.9 lb 3.9 lb 3.25 inches inches 8-12 seconds -8 feet UPC:

4 FIRE EXTINGUISHER Mariner 110 Fire Extinguisher Part number 427 Multipurpose use UL Rated 1-A, 10-B:C D I S P O S A B L E Suitable for use on Class A (trash, wood & paper), Class B (liquids & gases) and Class The Mariner 110 unit is fitted with a pressure gauge that provides at-a-glance status, is manufactured from bilingual nameplate fire is charged 2.5 lb of fire extinguishing UL approved strap retention supplied mounting Model Mariner 110 Multipurpose Dry Chemical UL rated 1-A,10-B:C U.S.C.G, DOT approved Supplied with retention strap Monoammonium Phosphate Suitable for use on most common fires 2.5 lb 3.9 lb 3.25 inches inches 8-12 seconds -8 feet UPC:

5 FIRE EXTINGUISHER Mariner 5 Fire Extinguisher Part number 435 Regular use UL Rated 5-B:C D I S P O S A B L E Suitable for use on Class B (liquids & gases) and Class The Kitchen/Garage unit is fitted with a pressure gauge that provides at-a-glance status, is manufactured from bilingual nameplate fire is charged 2 lb of fire extinguishing UL approved strap retention supplied mounting Model Mariner 5 Regular Dry Chemical UL rated 5-B:C U.S.C.G, DOT approved Supplied with retention strap Sodium Bicarbonate Suitable for use on liquid & energized electrical fires 2 lb 2.85 lb 3.25 inches inches 8-12 seconds 4- feet UPC:

6 R E C H A R G E A B L E FIRE EXTINGUISHER Mariner 340 Fire Extinguisher Part number Multipurpose use Rechargeable UL Rated 3-A, 40-B:C Suitable for use on Class A (trash, wood & paper), Class B (liquids & gases) and Class The Mariner 340 unit is fitted with a pressure gauge that provides at-a-glance status, is manufactured from tough metal valve assembly. bilingual nameplate fire is charged Tough impact resistant metal valve, handle & lever 5 lb of fire extinguishing UL approved wall hanger supplied metal mounting Supplied with U.S.C.G. approved Model Mariner 340 Multipurpose Dry Chemical UL rated 3-A, 40-B:C Supplied with metal strap Monoammonium Phosphate Suitable for use on most common fires 5.0 lb 9.0 lb 4.5 inches 1.07 inches seconds feet 195 psi UPC: PALLET 9

Fire Control Fire Extinguisher (FC5)

Fire Control Fire Extinguisher (FC5) Fire Control Fire Extinguisher (FC5) Part number 44010 Regular use Disposable UL Rated 5-B:C D I S P O S A B L E Suitable for use on Class B (liquids & gases) and Class The Fire Control FC5 unit is status,

More information

Fire, extreme heat, smoke, toxic fumes, noise, falling objects, uneven terrain, debris,

Fire, extreme heat, smoke, toxic fumes, noise, falling objects, uneven terrain, debris, Policy Sponsor: Assistant Vice President Facilities Management Approval Date: February 2010 Facilities Management Fire Extinguishers and Fighting Fires Safe Work Instructions Responsible Unit: Facilities

More information

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE Worldwide Safety Services Fire Extinguisher Training D 1 Objectives Understand the combustion process and different fire classes. Understand d fire extinguisher i types, operating procedures, capabilities,

More information

PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers

PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers MODEL 5 The Model 5 has a slim design for use on vehicles and machinery where space is limited. Typical applications include small trucks,

More information

Three elements of fire. Heat Oxygen Fuel. Remove one of the three and the fire is extinguished.

Three elements of fire. Heat Oxygen Fuel. Remove one of the three and the fire is extinguished. ABC s Three elements of fire Heat Oxygen Fuel Remove one of the three and the fire is extinguished. Fires are classified based on type of fuel. Extinguishers are also classified on the type of fire they

More information

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 7 Extinguisher Types Revised

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 7 Extinguisher Types Revised Engine Module Page 1 of 7 EXTINGUISHER TYPES Pressurized Water Extinguishers The stored pressure 2 1/2-gallon water extinguisher is rated at 2A. The extinguisher weighs about 30 LBS. The stream range is

More information

Fire Extinguisher Training

Fire Extinguisher Training Fire Extinguisher Training The Fire Triangle Fire Safety, at its most basic, is based upon the principle of keeping fuel sources and ignition sources separate. The Fire Triangle Three things must be present

More information

Data/ Specification Sheet

Data/ Specification Sheet Data/ Specification Sheet MONARCH Dry Chemical Automotive Paint Spray Booth Fire Suppression System TM 1. Fixed temperature mechanical or thermal detectors 2. Electrical conduit protecting stainless steel

More information

A. Section Includes: Fire extinguishers and cabinets including necessary accessories.

A. Section Includes: Fire extinguishers and cabinets including necessary accessories. SECTION 10522 FIRE EXTINGUISHERS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Fire extinguishers and cabinets including necessary accessories. B. Related Sections: 1. 09900 - Painting 2. 10400 - Identifying

More information

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS ANSUL Twin-Agent Fire Fighting/Securing Systems Specifications Models 450/50-B, 450/100-B, 900/100-B INDEX 1.0 GENERAL 1.1 References 1.2 Submittals 1.3 System Capabilities 1.4 Quality Control 1.5 Warranty,

More information

Twin-Agent Fire Fighting/Securing Systems Specifications

Twin-Agent Fire Fighting/Securing Systems Specifications Twin-Agent Fire Fighting/Securing Systems Specifications Models 450/50, 450/100, 900/100 & 1350/200 INDEX 1.0 GENERAL 1.1 References 1.2 Submittals 1.3 System Capabilities 1.4 Quality Control 1.5 Warranty,

More information

Extinguishers. Commercial Industrial High rise buildings

Extinguishers. Commercial Industrial High rise buildings Commercial Industrial High rise buildings Extinguishers Design, Supply, Installation, Testing, Commissioning, Maintenance, and Service of Firefighting and Fire Protection Systems Think fire protection......thank

More information

BCP ULC Classified BC Dry Chemical, 50lb pail BC SS ULC Classified BC Dry Chemical, 1200lb bulk sack 1,230.00

BCP ULC Classified BC Dry Chemical, 50lb pail BC SS ULC Classified BC Dry Chemical, 1200lb bulk sack 1,230.00 STEEL FIRE Model 750 & Model SUPER90 ABC Dry Chemical Agent STEEL FIRE EQUIPMENT manufactures ULC listed (ULC File #EX5581) dry chemical at our facility located in Mississauga (Greater Toronto Area), Canada.

More information

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND 1. GENERAL SPECIFICATION 1.1 A pre-engineered, fixed pipe, automatic dry chemical fire suppression system shall be provided and installed for the hazard including work area, plenums and all exhaust ventilation

More information

2007 Fire Equipment Product Catalog

2007 Fire Equipment Product Catalog BuckeyeCOMPLETE:Layout 1 5/24/07 4:06 PM Page 1 BUCKEYE FIRE EQUIPMENT American Made Since 1968 2007 Fire Equipment Product Catalog www.buckeyef.com BuckeyeCOMPLETE:Layout 1 5/24/07 4:06 PM Page 2 Company

More information

FIRE EXTINGUISHERS & CHEMICAL

FIRE EXTINGUISHERS & CHEMICAL FIRE EXTINGUISHERS & CHEMICAL 1 8 1 FIRE EXTINGUISHERS & CHEMICAL For Offices, Warehouses, & More! Amerex ABC DRY CHEMICAL FIRE EXTINGUISHERS use a monoammonium phosphate dry chemical to insulate Class

More information

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL NO. 05602 FOR AMEREX STORED PRESSURE, HAND PORTABLE DRY CHEMICAL FIRE EXTINGUISHERS. ABC (Ammonium Phosphate Base)

More information

FIRE AND FIRE FITTING By Mr. Prashant Sansare

FIRE AND FIRE FITTING By Mr. Prashant Sansare FIRE AND FIRE FITTING By Mr. Prashant Sansare What is mean by fire? CASE STUDY What Happened? Late one evening, a large storage tank containing a flammable liquid began to overflow. It was not detected

More information

Product Catalog MADE IN THE USA

Product Catalog MADE IN THE USA Product Catalog MADE IN THE USA 1 Hand Held Fire Extinguishers Page 5-14 ABC Dry Chemical Page 5 Standard Dry Chemical Page 6 Purple K Dry Chemical Page 7 Halotron Page 8 High Flow Page 9 Heavy Duty High

More information

Chapter 26 FIRE PROTECTION

Chapter 26 FIRE PROTECTION Chapter 26 FIRE PROTECTION 26-Title Page 1 INTENTIONALLY LEFT BLANK 26-Title Page 2 LIST OF EFFECTIVE PAGES Chapter Section Page No. Date 26 26-Title 1 2 26-LOEP 1 2 26-TOC 1 2 26-20 1 July 28, 2008 2

More information

June 2018 Safety Meeting Fire Extinguishers Part I

June 2018 Safety Meeting Fire Extinguishers Part I June 2018 Safety Meeting Fire Extinguishers Part I The portable fire extinguisher, one of the most common fire protection appliances in use today, is found in fixed facilities and on propane vehicles.

More information

SERT FIRE ELEMENTS & HAZ MAT

SERT FIRE ELEMENTS & HAZ MAT SERT FIRE ELEMENTS & HAZ MAT Fire Triangle Needed elements to sustain burning Firefighter / EMT Casey McIntosh Fire Tetrahedron Added 4 th element to Fire Triangle. The Combustion Process THE FIRE TETRAHEDRON

More information

HIGH PERFORMANCE HEAVY DUTY INDUSTRIAL STORED PRESSURE

HIGH PERFORMANCE HEAVY DUTY INDUSTRIAL STORED PRESSURE HIGH PERFORMANCE HEAVY DUTY INDUSTRIAL STORED PRESSURE ABC (AMMONIUM PHOSPHATE BASE),Regular (SODIUM BICARBONATE BASE), PURPKE K (POTASSIUM BICARBONATE BASE) OWNERS SERVICE MANUAL NO. 0566 INSTALLATION,

More information

OWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE

OWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE FOAM FIRE EXTINGUISHERS MODEL 254-6 LITER AFFF FOAM WITH SPRAY NOZZLE Model 250 2 ½ GAL.LON AFFF FOAM WITH ASPIRATED NOZZLE MODEL 252 2 ½ GAL.LON FFFP (ALCOHOL RESISTANT) FOAM WITH ASPIRATED NOZZLE OWNER'S

More information

smoke alarms carbon monoxide alarms fire extinguishers safety products productcatalog

smoke alarms carbon monoxide alarms fire extinguishers safety products productcatalog smoke alarms carbon monoxide alarms fire extinguishers safety products productcatalog safety RECONSIDERED Are you offering the most advanced line of safety products to your consumers? Today s homeowners

More information

TRAINING BULLETIN TOOLS 1 May 27, 2011 PRESSURIZED WATER EXTINGUISHER

TRAINING BULLETIN TOOLS 1 May 27, 2011 PRESSURIZED WATER EXTINGUISHER TRAINING BULLETIN TOOLS 1 May 27, 2011 1. DESCRIPTION Weight is approximately 30 lbs. Water 2½ gallons. Operating Pressure: 100 psi @ 70 degrees F. Note: Water expelled in 55 seconds. Stainless Steel Cylinder

More information

TYPES OF EXTINGUISHING AGENTS

TYPES OF EXTINGUISHING AGENTS 96 FIRE ENGINEERING S HANDBOOK FOR FIREFIGHTER I & II Fire extinguisher design and types All portable fire extinguishers use pressure to expel their extinguishing agents, but there are a few different

More information

What are the four things that must be present at the same time to produce fire?

What are the four things that must be present at the same time to produce fire? What are the four things that must be present at the same time to produce fire? Enough oxygen to sustain combustion, Enough heat to raise the material to its ignition temperature, Some sort of fuel or

More information

1. Portable fire extinguishers. 2. Fire-protection cabinets for portable fire extinguishers.

1. Portable fire extinguishers. 2. Fire-protection cabinets for portable fire extinguishers. SECTION 10 44 13 - FIRE-PROTECTION SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Portable Fire Extinguishers

Portable Fire Extinguishers Portable Fire Extinguishers Objectives (1 of 2) State the primary purposes of fire extinguishers. Define Class A fires. Define Class B fires. Define Class C fires. Define Class D fires. Define Class K

More information

NOTE: THIS DOCUMENT IS FOR INFORMATIONAL PURPOSES ONLY. THIS IS NOT AN OFFICIAL BID DOCUMENT.

NOTE: THIS DOCUMENT IS FOR INFORMATIONAL PURPOSES ONLY. THIS IS NOT AN OFFICIAL BID DOCUMENT. ANNUAL MAINTENANCE CONTRACT TO COVER FIRE EXTINGUISHER SERVICE FROM JULY, 208 THROUGH JUNE 30, 209 Supply labor and materials to perform annual maintenance service, inspection and certification for campus

More information

WHERE TO USE HOW TO USE

WHERE TO USE HOW TO USE WHERE TO USE Amerex manufactures an extensive variety of hand portable and wheeled fire extinguishers, both compliance (code required) and specialty types. Specialty type extinguishers are intended for

More information

Progressive Safety Services LLC 2

Progressive Safety Services LLC 2 Progressive Safety Services LLC 2 Oxygen - to sustain combustion Heat - to raise material to ignition temperature Fuel or combustible material Chemical - exothermic reaction Progressive Safety Services

More information

OWNERS SERVICE MANUAL NO INSTALLATION, OPERATING & SERVICING INSTRUCTIONS

OWNERS SERVICE MANUAL NO INSTALLATION, OPERATING & SERVICING INSTRUCTIONS STORED PRESSURE, WHEELED & STATIONARY 50 POUND DRY CHEMICAL FIRE EXTINGUISHERS ABC (AMMONIUM PHOSPHATE BASE), REGULAR (SODIUM BICARBONATE BASE), PURPLE K (POTASSIUM BICARBONATE BASE) OWNERS SERVICE MANUAL

More information

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING THE MOST ADVANCED TECHNOLOGY FOR PROTECTING SPECIAL HAZARDS There are numerous hazards where the use of dry chemical is the best option for firefighting, and where the use of portable fire extinguishers

More information

Environmental Guidance Fire Fighting Powder and Powder Fire Extinguishers

Environmental Guidance Fire Fighting Powder and Powder Fire Extinguishers Fact File 26 Environmental Guidance Fire Fighting Powder and Powder Fire Extinguishers Environmental Guidance Fire Fighting Powder and Powder Fire Extinguishers INTRODUCTION... 3 TYPES OF FIRE EXTINGUISHING

More information

Flammable liquids, gasoline, oil etc. Advantages. 21 B. Ø 920 mm 21 B. Ø 920 mm

Flammable liquids, gasoline, oil etc. Advantages. 21 B. Ø 920 mm 21 B. Ø 920 mm 1370 14133 14133 Powder Wheeled Fire Extinguisher kg 25 Approved EN 166-1:200, Marina MED, higest rate achieved - A IVB C CSI Certificate MED/0497/126/09 Organic solid materials, wood rubber, textiles

More information

CFSAC REGULATORY REFORM SUBCOMMITTEE RECOMMENDATION REPORT

CFSAC REGULATORY REFORM SUBCOMMITTEE RECOMMENDATION REPORT March 1, 2018 CFSAC REGULATORY REFORM SUBCOMMITTEE RECOMMENDATION REPORT SUBJECT: EVALUATION OF EXISTING COAST GUARD REGULATIONS, GUIDANCE DOCUMENTS, INTERPRETATIVE DOCUMENTS, AND COLLECTIONS OF INFORMATION

More information

Salt Lake Community College FIRE EXTINGUISHER TRAINING

Salt Lake Community College FIRE EXTINGUISHER TRAINING Salt Lake Community College Legal Basis for Training Occupational Safety and Health Administration (OSHA) Occupational Safety and Health Standards 29 CFR Part 1910 Subpart L Fire Protection Standard 1910.157

More information

P3HAFEX. System Description

P3HAFEX. System Description P3 P3 5B- extinguisher with Standard bracket P3 engineering GmbH Blohmstraße 12 21079 Hamburg Germany Compiled Checked Approved Date: Date: Date: Name: Name: Name: Signature: Signature: Signature: Page:

More information

Product Catalog. Your Source for World Class Fire Protection Equipment. Hand Held Extinguishers. Restaurant Fire Suppression Systems

Product Catalog. Your Source for World Class Fire Protection Equipment. Hand Held Extinguishers. Restaurant Fire Suppression Systems Product Catalog Your Source for World Class Fire Protection Equipment Foam Concentrates & Hardware Restaurant Fire Suppression Systems Hand Held Extinguishers Wheeled & Specialty Fire Extinguishers 1 Hand

More information

Superior by Design The Kidde ADS TM FM-200 System

Superior by Design The Kidde ADS TM FM-200 System A UTC Fire & Security Company Superior by Design The Kidde ADS TM FM-200 System Engineered to Provide Exceptional Performance The Kidde ADS FM-200 System is an innovative system developed by Kidde engineers

More information

FIRE SAFETY (But Were Afraid To Ask)

FIRE SAFETY (But Were Afraid To Ask) Broward College Emergency, Safety & Security Office Everything You Wanted To Know About FIRE SAFETY (But Were Afraid To Ask) 1. Pull fire alarm box 2. Call Campus Safety 954-201 HELP (4357) 3. Dial 9-911

More information

DC-1000 DECAL WORLD KIT. Part # Description Qty Part # Description Qty DECAL KIT

DC-1000 DECAL WORLD KIT. Part # Description Qty Part # Description Qty DECAL KIT DC-00............... American Flag () DC-00.................. No Riders () DC-00............ Finger pinch point () DC-00......... Warning serious injury () DC-005.............. Fasten seat belt () DC-006.....

More information

& Fire Extinguisher Training

& Fire Extinguisher Training & Fire Extinguisher Training D The fire is an exothermic reaction. Ignition Flammable material + air (O2) ----------> CO 2 +H 2 O+Heat Temperature The evolved heat will further promote the reaction to

More information

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

S12 Fire Safety Risk Assessment H&SFS01-1 / 9 S12 Fire Safety Risk Assessment H&SFS01 Risk ratings The following risk ratings are based on two factors: The overall fire risk rating for the site The risk rating for the individual recommendations /control

More information

Tel Web: dyayan.com

Tel Web: dyayan.com 1 Our Products DYAYAN specializes in three main areas: - Manufacturing of Dry Chemical Powders - Manufacturing of Foam Concentrates - Project designing, assembly and maintenance of Fire Safety Systems.

More information

Extinguisher Chemical Refill

Extinguisher Chemical Refill Halotron I Clean Agent For A, B & C Fires The most broadly tested and approved 1211 replacement product available that s safe, environmentally friendly, effective and easy-to-use! Halotron is a clean fire

More information

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers READY FOR ACTION WHEN YOU ARE. Every year, cooking accidents, unattended candles, electrical failures, careless smoking and other incidents

More information

Product Catalog. Electrical Distributor SMOKE ALARMS CO ALARMS HEAT ALARMS FIRE EXTINGUISHERS. Volume 14

Product Catalog. Electrical Distributor SMOKE ALARMS CO ALARMS HEAT ALARMS FIRE EXTINGUISHERS. Volume 14 Product Catalog Electrical Distributor Volume 14 SMOKE ALARMS CO ALARMS HEAT ALARMS FIRE EXTINGUISHERS 1 Cost Effective Retrofit & Remodel Solutions Wireless interconnect technology eliminates the need

More information

HALOTRON I CLEAN AGENT FOR A, B & C FIRES REGULAR B:C FIRE EXTINGUISHERS PURPLE K B:C POTASSIUM BICARBONATE EXTINGUISHERS

HALOTRON I CLEAN AGENT FOR A, B & C FIRES REGULAR B:C FIRE EXTINGUISHERS PURPLE K B:C POTASSIUM BICARBONATE EXTINGUISHERS HALOTRON I CLEAN AGENT FOR A, B & C FIRES Halotron I clean fire extinguishing agent discharges as a rapidly evaporating liquid, which is non-conductive, non-corrosive, and leaves behind no residue. Determined

More information

FIRE-FIGHTING POWDERS. John Dowling. Kidde PLC

FIRE-FIGHTING POWDERS. John Dowling. Kidde PLC FIRE-FIGHTING POWDERS John Dowling. Kidde PLC FOAM UNDER FIRE. A workshop organised by IFE. 20th December 2004. The Reebok Stadium, Greater Manchester. Fire-Fighting Powders. WHAT ARE THEY? Powdered Chemicals

More information

Product Catalog. Product Catalog Electrical Market Volume 11

Product Catalog. Product Catalog Electrical Market Volume 11 Product Catalog Product Catalog Electrical Market Volume 11 1 Residential Placement Guide for AC 120-volt Interconnectable BRK & First Alert Products Agency Recommendations: NFPA 72 recommends a smoke

More information

Quality is Behind the Diamond

Quality is Behind the Diamond Quality is Behind the Diamond Amerex manufactures an extensive variety of hand portable and wheeled fire extinguishers, both compliance (code required) and specialty types. Specialty type extinguishers

More information

E4218 Fire Extinguisher Basic Training. Leader s Guide

E4218 Fire Extinguisher Basic Training. Leader s Guide E4218 Fire Extinguisher Basic Training Leader s Guide FIRE EXTINGUISHER BASIC TRAINING This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation. Featured are: INTRODUCTION

More information

Purple K B:C Potassium Bicarbonate Extinguishers

Purple K B:C Potassium Bicarbonate Extinguishers Halotron I Clean Agent For A, B & C Fires Halotron I clean fire extinguishing agent discharges as a rapidly evaporating liquid, which is non-conductive, non-corrosive, and leaves behind no residue. Determined

More information

FIRE EXTINGUISHER SPACING & INSTALLATION GUIDELINES

FIRE EXTINGUISHER SPACING & INSTALLATION GUIDELINES FIRE EXTINGUISHER SPACING & INSTALLATION GUIDELINES Town of Brighton Office of the Fire Marshal October 2018 Fire Extinguisher Spacing & Installation Guidelines Scope The Fire Code of New York specifies

More information

A Guide for Meeting NFPA 10 Subsection

A Guide for Meeting NFPA 10 Subsection TECHNICAL BULLETIN A Guide for Meeting NFPA 10 Subsection 5.5.1.1 Extinguishers for Pressurized Flammable Liquids and Pressurized Gas Fires One Stanton Street / Marinette, WI 54143-2542, USA / +1-715-735-7411

More information

smoke alarms carbon monoxide alarms fire extinguishers safety products productcatalog

smoke alarms carbon monoxide alarms fire extinguishers safety products productcatalog smoke alarms carbon monoxide alarms fire extinguishers safety products productcatalog safety RECONSIDERED Are you offering the most advanced line of safety products to your consumers? Today s homeowners

More information

Portable Fire Extinguishers

Portable Fire Extinguishers Portable Fire Extinguishers Workbook Activities The following activities have been designed to help you. Your instructor may require you to complete some or all of these activities as a regular part of

More information

Leader s Guide 2007 CLMI Training

Leader s Guide 2007 CLMI Training C3585 FIRE EXINGUISHERS: Ready To Respond Leader s Guide 2007 CLMI Training FIRE EXTINGUISHERS:Ready To Respond This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation.

More information

PRODUCT CATALOG FOR ALL INFORMATOIN AND REQUIREMENTS. WEB:

PRODUCT CATALOG FOR ALL INFORMATOIN AND REQUIREMENTS. WEB: PRODUCT CATALOG 2012-2013 FOR ALL INFORMATOIN AND REQUIREMENTS WEB: www.mefasco.com EMAIL: info@mefasco.com WHERE TO USE Amerex manufactures an extensive variety of hand portable and wheeled fire extinguishers,

More information

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM 1. GENERAL SPECIFICATION 1.1 An Engineered Carbon Dioxide Fire Suppression System shall be installed to meet a minimum design concentration of %, by volume in all designated spaces/areas to be protected.

More information

READY FOR CHANGE. A Guide for Meeting the NFPA Compliance Standard for Portable Fire Extinguishers

READY FOR CHANGE. A Guide for Meeting the NFPA Compliance Standard for Portable Fire Extinguishers READY FOR CHANGE A Guide for Meeting the NFPA 10-2010 Compliance Standard for Portable Fire Extinguishers THE CHALLENGES A QUICK REVIEW The NFPA 10 Standard contains many guidelines that may impact you

More information

COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST

COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST 98 Columbus Street, Pointe Claire, QC, Canada H9R 4K4 info@caspaerospace.com www.caspaerospace.com T: 514-630-7777 F: 514-630-9999 HAND PORTABLE AIRCRAFT FIRE EXTINGUISHERS 3.0 lb. Halon 1211 Part No.

More information

UNIT 7: FIRE SAFETY. Fire Chemistry: How fire occurs, classes of fire, and choosing the correct means to extinguish each type of fire.

UNIT 7: FIRE SAFETY. Fire Chemistry: How fire occurs, classes of fire, and choosing the correct means to extinguish each type of fire. In this unit you will learn about: Fire Chemistry: How fire occurs, classes of fire, and choosing the correct means to extinguish each type of fire. Fire Hazards: Potential fire hazards in the home and

More information

"USING FIRE EXTINGUISHERS"

USING FIRE EXTINGUISHERS PRESENTER'S GUIDE "USING FIRE EXTINGUISHERS" Part of the "SAFETY MEETING KIT" Series Quality Safety and Health Products, for Today...and Tomorrow OUTLINE OF MAJOR PROGRAM POINTS The following outline summarizes

More information

COMPONENT MAINTENANCE MANUAL

COMPONENT MAINTENANCE MANUAL MAINTENANCE INSTRUCTIONS WITH ILLUSTRATED PARTS LIST HALON 1/ 1.2/ 2.5 AIR TOTAL List of Portable Fire Extinguishers Part No. Type: 74-00 HAL 1.0 74-20 HAL 1.2 74-21 HAL 1.2 (LH) 74-22 HAL 1.2 (AF) 76-00

More information

ANSUL I-101 INDUSTRIAL FIRE SUPPRESSION SYSTEM TECHNICAL MANUAL VEHICLE PAINT SPRAY BOOTH PROTECTION MANUAL

ANSUL I-101 INDUSTRIAL FIRE SUPPRESSION SYSTEM TECHNICAL MANUAL VEHICLE PAINT SPRAY BOOTH PROTECTION MANUAL ANSUL I-101 INDUSTRIAL FIRE SUPPRESSION SYSTEM TECHNICAL MANUAL VEHICLE PAINT SPRAY BOOTH PROTECTION MANUAL OPEN FACE PAINT SPRAY BOOTH PROTECTION MANUAL GENERAL PURPOSE: TOTAL FLOODING/LOCAL APPLICATION

More information

Using Fire Extinguishers. Leaders Guide and Quiz

Using Fire Extinguishers. Leaders Guide and Quiz ! Using Fire Extinguishers Leaders Guide and Quiz 3578 INTRODUCTION TO THE PROGRAM Structure and Organization Information in this program is presented in a definite order so that employees will see the

More information

Hospitals and Major Medical Centers

Hospitals and Major Medical Centers Hospitals and Major Medical Centers INERGEN Fire Suppression Systems AUTOPULSE Detection and Control Equipment SENTRY Hand Portable Fire Extinguishers Medical centers have special concerns for fire safety

More information

GUILFORD COUNTY SCHOOLS

GUILFORD COUNTY SCHOOLS GUILFORD COUNTY SCHOOLS Fire Extinguisher Plan Policy In accordance with the regulations established by the United States Department of Labor pursuant to the Occupational Safety and Health Act and the

More information

COMPONENT MAINTENANCE MANUAL

COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST HALON 1/ 1,2/ 2,5 AIR TOTAL List of Portable Fire Extinguishers Part No. Type: 74-00 HAL 1,0 74-20 HAL 1,2 74-21 HAL 1,2 (LH) 76-00 HAL 2,5 COMPONENT MAINTENANCE MANUAL TOTAL

More information

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS (By authority conferred on the director of the department of licensing and regulatory affairs by sections

More information

Installation, Operation, Maintenance, & Troubleshooting Model: CLS36-440V Electric Cruise Line Salamander Serial:

Installation, Operation, Maintenance, & Troubleshooting Model: CLS36-440V Electric Cruise Line Salamander Serial: Installation, Operation, Maintenance, & Troubleshooting Model: CLS36-440V Electric Cruise Line Salamander Serial: Lang Manufacturing Company 10 Sunnen Dr, St. Louis, MO 63143 Part No: 2M-W1257, Rev. -

More information

Risk Management Department. Fire Extinguishers

Risk Management Department. Fire Extinguishers Risk Management Department Fire 1 Introduction to Fire Every school facility is equipped with fire extinguishers for staff to use to suppress fires. Used properly, a fire extinguisher can be an effective

More information

FIRE EXTINGUISHER. Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley Extinguishers

FIRE EXTINGUISHER. Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley Extinguishers FIRE EXTINGUISHER Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley U.A.E K.S.A www.nteico.com FIRE EXTINGUISHER Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley Extinguishers INDEX NTEICO

More information

Emergency Operating Procedures for: Fire and Emergency

Emergency Operating Procedures for: Fire and Emergency Serenity Houseboat I. Overview Emergency Operating Procedures for: Fire and Emergency Fire is an infrequent but terrifying occurrence on board a boat. Because of the environment and potential distances

More information

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual 008094 All fire extinguishers should be installed, inspected and maintained in accordance with

More information

MAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems

MAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems MAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems ANSUL PIONEERED DRY CHEMICAL FIRE PROTECTION IN 1939, WHICH HELPED CREATE LARGE DRY CHEMICAL SYSTEMS WITH SUPERIOR FIREFIGHTING CAPABILITIES

More information

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge ENSPECO Recovery/ Recycle/ Evacuate/ Recharge RMS 3012 RMS 3034 Approved by UL/SAE to J-1991 R12 Purity Standards Approved by UL/SAE to J-2210 R134 Purity Standards This semi-automatic machine will recover

More information

OWNERS SERVICE MANUAL NO

OWNERS SERVICE MANUAL NO OWNERS SERVICE MANUAL NO. 05608 INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS for AMEREX STORED PRESSURE WHEELED & STATIONARY 125/150 POUND DRY CHEMICAL FIRE EXTINGUISHERS WHEELED STATIONARY Model

More information

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK STRIKE FIRST CORPORATION AKC SERVICE MANUAL (v1) UL / ULC WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK All fire extinguishers should be installed, inspected

More information

Powder Extinguisher ABC (stored pressure) Portable powder extinguishers

Powder Extinguisher ABC (stored pressure) Portable powder extinguishers Powder Extinguisher ABC (stored pressure) Portable powder extinguishers The Dräger powder extinguisher are an all-purpose fire extinguisher and are especially suited for flammable liquids and fires involving

More information

ADDENDUM #1: MODIFICATIONS AND ADDITIONS TO CONTRACT DOCUMENTS

ADDENDUM #1: MODIFICATIONS AND ADDITIONS TO CONTRACT DOCUMENTS Annex Laundry and Shower Alterations ADDENDUM #1 March 7, 2019 ADDENDUM #1: MODIFICATIONS AND ADDITIONS TO CONTRACT DOCUMENTS A. Invitation to Bid - Call for Bids has been modified as follows: 1. Notice

More information

BROWARD COLLEGE FIRE SAFETY GUIDE

BROWARD COLLEGE FIRE SAFETY GUIDE BROWARD COLLEGE FIRE SAFETY GUIDE An acceptable fire protection program includes those fire protection policies, requirements, technical criteria, analyses, administrative procedures, systems and hardware,

More information

Pre-Engineered Fire Suppression

Pre-Engineered Fire Suppression Marine Fire Pre-Engineered Fire Suppression 727 Series Installation & Maintenance Manual Catef srl - Marine Fire Via Grecale 33 55049 Viareggio (LU) Italy Tel: +39 0584 390609 Fax: +39 0584 397752 E-mail:

More information

For Kidde 10 lb dry chemical fire extinguishers with nylon Zytel (black plastic) valve assemblies & steel cylinders.

For Kidde 10 lb dry chemical fire extinguishers with nylon Zytel (black plastic) valve assemblies & steel cylinders. For Kidde 10 lb dry chemical fire extinguishers with nylon Zytel (black plastic) valve assemblies & steel cylinders. IMPORTANT: MAKE SURE YOU FULLY FAMILIARIZE YOURSELF WITH THE PROCEDURES DESCRIBED IN

More information

PRESTO DRY POWDER FIRE EXTINGUISHERS - AB:E

PRESTO DRY POWDER FIRE EXTINGUISHERS - AB:E - 1 - PRESTO DRY POWDER EXTINGUISHERS - AB:E Certified & Approved to AS/NZS 1841.5 Deep drawn steel cylinder with welded base and robust skirt., giving extra resistance to standard corrosive environments

More information

Institute for Plasma Research Welcomes you all on

Institute for Plasma Research Welcomes you all on Institute for Plasma Research Welcomes you all on Presented By: D.V.MODI, Safety Officer, IPR Compiled by: SAFETY COMMITTEE, IPR WHAT IS FIRE? The self-sustaining process of rapid oxidation of a fuel,

More information

Emergency Action Plans and Fire Prevention Plans. Are employers required to have Emergency Action Plans and/or Fire Prevention Plans?

Emergency Action Plans and Fire Prevention Plans. Are employers required to have Emergency Action Plans and/or Fire Prevention Plans? Emergency Action Plans and Fire Prevention Plans Are employers required to have Emergency Action Plans and/or Fire Prevention Plans? Although employers are required to have an Emergency Action Plan (EAP)

More information

Firefighting. It is the temperature at which a substance will continue to burn, when ignited.

Firefighting. It is the temperature at which a substance will continue to burn, when ignited. Firefighting 1. What is Flash Point? A lowest temperature of a substance, at which there is sufficient vapor to produce a flash momentarily, is called the Flash point of that substance. 2. What is Fire

More information

FIRE PROTECTION. /fireprotection FIRE PROTECTION EDARLEY.COM/FIREPROTECTION HALOTRON I CLEAN AGENT FOR A, B & C FIRES

FIRE PROTECTION. /fireprotection FIRE PROTECTION EDARLEY.COM/FIREPROTECTION HALOTRON I CLEAN AGENT FOR A, B & C FIRES FIRE PROTECTION CO ALARMS GAS DETECTION HYDRANT BOOSTERS MOUNTS SPRINKLER PUMP SOLUTIONS SUPPRESSION SYSTEMS Shop /fireprotection HALOTRON I CLEAN AGENT FOR A, B & C FIRES Halotron I clean fire extinguishing

More information

Explosion Venting and Suppression of Bucket Elevator Legs, G90-990

Explosion Venting and Suppression of Bucket Elevator Legs, G90-990 Page 1 of 6 G90-990 Explosion Venting and Suppression of Bucket Elevator Legs Explosion vents and explosion suppression devices limit the danger and damage associated with grain dust explosions. This NebGuide

More information

OWNERS SERVICE MANUAL

OWNERS SERVICE MANUAL OWNERS SERVICE MANUAL NO. 08220 INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS for AMEREX MODEL 570 30 POUND (13.6 KG) CLASS D SODIUM CHLORIDE, STORED PRESSURE FIRE EXTINGUISHER FOR COMBUSTIBLE METAL

More information

Consult the manufacturer for assistance in editing this guide specification for specific Project applications where necessary.

Consult the manufacturer for assistance in editing this guide specification for specific Project applications where necessary. This guide specification was prepared utilizing 3-part format recommended by the Construction Specifications Institute (CSI), and generally incorporates recommendations from their SectionFormat /Page Format,

More information

Read the instructions label: An emergency is not the time to find out how an extinguishers works.

Read the instructions label: An emergency is not the time to find out how an extinguishers works. Read the instructions label: n emergency is not the time to find out how an extinguishers works. xtinguisher ize For further information, please call It is important to know that fire extinguishers are

More information

FIREWORLD DRY POWDER ABE FIRE EXTINGUISHERS

FIREWORLD DRY POWDER ABE FIRE EXTINGUISHERS - 1 - WORLD DRY POWDER ABE EXTINGUISHERS Certified & Approved to AS/NZS 1841.5 Fireworld Deep drawn steel cylinder with welded base and robust skirt., giving extra resistance to standard corrosive environments

More information

FIRE EQUIPMENT & SAFETY SUPPLIES

FIRE EQUIPMENT & SAFETY SUPPLIES FIRE EQUIPMENT & SAFETY SUPPLIES HANGERS F10695 Red Hanger for 2-1/2 lb. Fire Extinguisher F1069 Red Strap on Hanger for 5 lb. Fire Extinguisher F10696 Red Hanger for 5 lb. Fire Extinguisher F10691 Red

More information