CR-39 SAMPLING OF INDOOR RADON IN SOUTHERN ROMANIA *

Size: px
Start display at page:

Download "CR-39 SAMPLING OF INDOOR RADON IN SOUTHERN ROMANIA *"

Transcription

1 CR-39 SAMPLING OF INDOOR RADON IN SOUTHERN ROMANIA * ANGELA VASILESCU Horia Hulubei National Institute for Nuclear Physics and Engineering (IFIN), P.O.Box MG-6, RO Bucharest-Magurele, Romania, angela@.nipne.ro Received November 15, 2012 The paper presents studies associated with the implementation of the indoor radon measurement technique using CR-39 nuclear track detectors and an automatic Radosys set-up in the Applied Nuclear Physics Department of the Horia Hulubei National Institute for Physics and Nuclear Engineering and new, in-situ, indoor radon data in various locations in South/South-East Romania. Key words: indoor radon, solid-state nuclear track detectors, CR INTRODUCTION The new Solid State Nuclear Track Detector (SSNTD) Indoor Radon Laboratory of the Applied Nuclear Physics Department at the Horia Hulubei National Institute of Physics and Nuclear Engineering (IFIN) employs CR-39 plastic detectors and a Radosys set-up [1]. It is mainly aimed at the regional coverage of the necessities of indoor radon measurements especially in the Southern part of Romania, but also to become a reliable member of a National Radon network. The implementation of this technique brought along a series of tests for the better understanding of this already well established method, and was doubled by indoor sampling measurements at various sites. The geographical region covered by our study was expected to be of reasonably low impact, compared to radon prone areas in the country (e.g. Crucea in Moldova, Stei in Transylvania), however, as to our present knowledge, the statistic of existing measurements for this region is low and any new data are welcome. Radon originates from the 238 U Ra natural decay series and escapes into air easily from the material in which it is formed (be it soil, rocks, water or building materials). The air we inhale (outdoors or indoors) contains radon. Average radon * Paper presented at the First East European Radon Symposium FERAS 2012, September 2 5, 2012, Cluj-Napoca, Romania. Rom. Journ. Phys., Vol. 58, Supplement, P. S311 S319, Bucharest, 2013

2 S312 Angela Vasilescu 2 levels are of 8 Bq/m 3 for continental outdoors, at 1m from the soil, and only 0.04 Bq/m 3 above the sea. Indoor radon concentrations reach orders of magnitude higher values, typically Bq/m 3 up to maximum values of several thousands of Bq/m 3 in radon prone areas [2]. In temperate climate, heat conservation and reduced ventilation habits increase the radon levels, especially in the cold months, determining, e.g. for Romania, an increase of the measured levels by a factor of about 2 [3]. Published data show e.g. values in the limits of Bq/m 3, with an arithmetic mean of (115±48) Bq/m 3 for measurements performed in winter, spring and summer for several sites in Transylvania [4-5]. 2. EQUIPMENT AND PROCEDURE The implementation of the CR-39 SSNTD technique in IFIN was started by A. Danis with the development of a state-of-art radon probe and calibration chamber [6], and continued in our new Radon lab [7]. Presently we use Radosys equipment [1], 10x10 mm 2 CR-39 detector chips in RSKS type chambers, with 4.5 h etching in 25% NaOH at 90ºC in the Radobath RSB4 unit. The reading of the tracks and the calculation of track density is done automatically with Radometer 2000, employing routine or slightly modified counting programs for small round tracks, provided by the manufacturer. The exposure and radon volume concentration is evaluated using calibration factors provided by the manufacturer of the chips. In the routine field measurements, we used automatic reading, repeated three times, with calibration for each measurement. In the intercomparison tests we read the detector chips five to ten times and applied the Chauvenet exclusion test for outliers. We also used a modified slower reading routine, with repeated focalization on the surface of the chip, both in separate individual calibration at one reading and in a version of repeated measurement three to five times at the same focalization, in order to reduce the spread between readings. The final choice for the routines adopted for the procedures to be used in our lab was to apply the fast routine for the field measurements (repeated five times), while for intercomparison and quality control exercises we decided for the modified slow method, and check also all the other options. At each site ( point of measurement ) we installed two Radosys detectors, and for each session we kept two blank background chips, to monitor the CR-39 set used. The conditions for the experimental tests performed during the implementation of this radon measuring system will be described together with the discussion of the results.

3 3 CR-39 sampling of indoor radon in Southern Romania S RESULTS AND DISCUSSION In the process of evaluation of our procedures and their standardization, we performed several exercises, including comparative readings by human operator with an optical microscope, comparisons of our previous manual scanning technique [7] with the automatic Radosys system measurements, parallel counting and measurement. We also included some field measurements in our comparisons. The following evaluation tests were the most significant to define our working procedures: Intercomparison exercises with CR-39 automatic and operator reading Repeatability and reproducibility tests, and Background survey of unexposed (blank) detectors. Automatic reading is a sensitive issue in the very low density region (for background studies in particular), where various program variations have been tested, with operator supervision of the accuracy in the identification of α tracks. A problem which cannot be neglected at very low densities is the misidentification of various unavoidable defects (etching defects, impurities, scratches) as tracks, which transfer mainly into higher final values. But also some real α tracks can be lost, especially in the fast (standard) routine. If such a background correction is then applied in the lower radon concentration domain, it can lead to underestimation of the actual radon exposure. Several trial tests in state-of-art calibration vessels both in the IFIN and in the Cluj-Napoca labs and parallel reading of detector sets etched in both laboratories were performed in order to compare our results with the Environmental Radioactivity and Nuclear Dating group at Babes-Bolyai University (UBB). Both laboratories used Radosys systems, but of different generations and, accordingly, slightly different etching recipes (5h at UBB) and evaluation software versions. In the most elaborate test, we used 20 detectors, and 10 background detectors (all from one batch). The detectors were exposed in the UBB radon chamber, and then divided between the two labs (two sets of 10), together with the background detectors (5 blanks to each lab), for etching. The read-out was done for both (10+5) detector sets in both laboratories, and the final results were compared. The difference in the results obtained in the two laboratories was within 3.6%. As a general rule, the IFIN results were somewhat lower, but with better reproducibility of the track density for both etching conditions: σ n (IFIN)/σ n (UBB)= 0.28/0.34 (etch IFIN); σ n (IFIN)/σ n (UBB)=0.39/0.57 (etch UBB).

4 S314 Angela Vasilescu 4 The repeatability of the measurements at IFIN was tested for track density evaluation on ten repeated measurements on a set of twelve chips in the tracks/mm 2 range, and was better than 99%. The reproducibility of the measurements was tested on two sets of ten detectors exposed in the same conditions, and it varied between %. Our first participation at an international intercomparison exercise (2011 Intercomparison exercise in field conditions Saelices el Chico, Spain) yielded good results [8]: of the three domains of exposure, our results were situated both in the low (110 kbq/m 3 ) and high (3800 kbq/m 3 ) exposure region within 1σ of the average, and within 2σ for the intermediate exposure (700 kbq/m 3 ). The final report [8] situated the IFIN results in class A (better than 10% from the overall average of the participants) for the low and high exposure and class B (better than 15%) for the intermediate exposure. This exercise used three sets of 15 detectors for the three exposure values and a set of 15 transit detectors (mounted chips), which accompanied the devices sent to Spain and back, and were etched in the same session. We also monitored this batch with four unexposed chips, for our background evaluation. This was not imposed by the intercomparison exercise, but is an internal checking routine of our detector batches BACKGROUND STUDIES We performed a study of the background for the CR-39 chips from two batches of detectors we used for measurements during the years The background detectors were etched in each measurement session together with the field detectors, and were used in the evaluation of the background corrections. In between the sessions, the detectors were stored packaged in a freezer, they were extracted from the original packaging at the same time with the field detectors and kept wrapped firmly and packaged, in the laboratory, at room temperature. We used a minimum of two (unmounted) CR-39 chips as background detectors at each etching session. The timeline for the detectors can be reconstructed from the laboratory logbook (from arrival in the lab to unpacking and etching). During the monitored time, we used two different batches, series J (until 2010) and series T, manufactured by Radosys Ltd. Due to the fact that the lab did not fulfill yet the necessary legal conditions for authorization for third party measurements (e.g. intercomparison results, elaboration and approval of all quality assurance procedures needed), during this time, only tests and field sampling measurements were performed as research. (The number of detectors used was

5 5 CR-39 sampling of indoor radon in Southern Romania S315 therefore also limited.) Figure 1 shows the track density values obtained on batches J and T. The average Poisson uncertainty for background was ~19%. A batch is delivered in several sheets, packaged individually in radon free aluminized bags, with cut and marked chips glued on a foil, from which the chips are extracted with tweezers and mounted in the radon (monitor) device (or wrapped as blanks, as already mentioned). The background detectors were selected randomly from the set of unexposed chips taken for a measurement session (field or other test). The time dependence (time is correlated with the number of the detector, as the bags were opened in increasing order of the numbers) is not evident, and we see rather random local non-uniformities in the batch (more evident for the already used-up J series). Fig. 1 CR-39 background track density variation in two detector series (batches). Differences in the background densities up to 50% have been seen even within the set used in the same session. In the cases when only a pair of detector was used, the decision is difficult: the chips had to be analyzed carefully, checked by microscope, to see whether the discrepancy was not due to the program or some material or etching defects. In most cases, the differences could not be explained by the presence of an accidentally bad chip. The background results on the T series are lower and less spread.

6 S316 Angela Vasilescu 6 Fig. 2 Frequency distribution of background track density for the J and T CR-39 chips. Fig. 2 presents the frequency distribution of background track densities measured on both detector series. The background correction can amount in the typical (2 3 months) exposures up to Bq/m 3, which is definitely high, representing about 10% of the warning level at 100 Bq/m 3 recommended by the World Health Organization (WHO) [9]. This aspect might need further investigation, and a reasonable decision in the acceptance of a measurement especially in the low track density region, where the background correction could be of significant impact, leading to the underestimation of the radon risk FIELD MEASUREMENTS As the final goal is actually the measurement in field conditions, we used CR-39 RSKS detectors in the cold season (late autumn/winter/early spring) in pairs of two, installed in various locations, in homes mainly, in Bucharest and in Ilfov county (Magurele, Ciorogarla, Copaceni, Buftea, Corbeanca), in Giurgiu (Giurgiu), Fetesti (Ialomita), Cernavoda (Constanta), Busteni (Prahova), Mogosesti, Stilpeni and Corbsori (Arges). (The location of the sites is presented on an edited Google map, see Fig. 3). Some of these sites were only temporarily inhabited, so, in those cases, the results correspond to a worst case scenario as to ventilation conditions.

7 7 CR-39 sampling of indoor radon in Southern Romania S317 Fig. 3 Location of field measurements by CR-39 SSNTD (black squares on an edited Google map). The measurements were performed in several campaigns, starting with 2007 to Some sites were measured several times, especially those where the home owners responded to our first results with changes. We noticed an improvement in a few cases after repairs or changing ventilation habits, but in some cases the new measurement did not show any change or even an increase above the 200 Bq/m 3 level shown in the plot in Fig. 4a. Figure 4 summarizes the data on the field measurements: the plot (a) shows the measured values for each location, and the histogram (b) presents the frequency distribution of the radon concentration in Bq/m 3. All the experimental values in the plot are averages over two detectors put in the same location with one exception, when a detector was broken by accident. The time of exposure was typically 2-3 months, and the transit times were minimized (from a few hours to a few days - less than one week). The volunteers participating in the survey were instructed to keep the devices in radon free condition, as much as possible (e.g. in open air), until they could be returned to the lab. Action levels recommended by ICRP [10] for indoor radon levels are between Bq/m 3, and the value accepted is a political decision for every country, depending on the local geology and affordable costs. The latest recommended (WHO) warning level of 100 Bq/m 3 is also shown in Fig. 4a [9].

8 S318 Angela Vasilescu 8 a) b) Fig. 4 CR-39 sampling in various locations in Southern Romania, between 2007 and 2011/2012, in the cold season (a); frequency distribution of radon concentration (b). 4. CONCLUSIONS The IFIN Indoor radon lab can perform reliable measurements employing CR-39 detectors and a Radosys system.

9 9 CR-39 sampling of indoor radon in Southern Romania S319 Different sets of detectors can have variations of background track densities, but differences can be seen within the same set as well. With careful handling, storing and monitoring, their lifetime can be prolonged after the one stated by the manufacturer. Due to the automatic statistical counting routine, it is reasonable to evaluate whether the background correction should be taken into account at each measurement or not at all, or its impact on the result discussed separately, depending on the character of the measurement (research, accuracy evaluation of the method or routine mapping measurements). The field measurements showed reasonably low values, with a few exceptions, to confirm our expectations for the Southern part of Romania. Acknowledgements. Financial support for this work was ensured by the National Agency for Scientific Research ANCS, in part by the 2CEX and PN projects. The very good collaboration and useful discussions with the members of the Environmental Radioactivity and Nuclear Dating group led by Professor Constantin Cosma at the Babes-Bolyai University (Professor Cosma and Ms. Kinga Szacsvai, in particular) during the implementation of the CR-39/Radosys system at IFIN are acknowledged by the author. Thanks go also to all the volunteers participating in the field survey. REFERENCES 1. RADOSYS LTD., Technical information, 2. IAEA - Radiation protection against radon in workplaces other than mines, Safety Reports Series No. 33, Vienna, C. Cosma, D. Ristoiu, A. Poffijn, G. Messen, Radon in various environmental samples in the Herculane spa, Cerna Valley, Romania, Env. International 22, Suppl.1 (1996) C. Cosma, K. Szacsvai, A. Dinu, D. Ciorba, T. Dicu, L. Suciu, Preliminary integrated indoor radon measurements in Transylvania (Romania), Isot. Env. Health Studies 45:3 (2009) C. Cosma, D. Ciorba, A. Timar, K. Szacsvai, A. Dinu, Radon exposure and lung cancer risk in Romania, Journ. Env. Prot. Ecol., ISSN , book 1 (2009) Danis et al., System for calibration of track detectors used in gaseous and solid alpha radionuclides monitoring, Rad. Meas. 34 (2001) I.A. Ghita, A. Vasilescu, Radon assessment with solid-state nuclear track detectors in Bucharest and its surrounding region, Rom. Rep. Phys. 63:4 (2011) J.L. Gutierrez-Villa et al., International Intercomparison Exercise on Natural Radiation Measurements under Field Conditions, Saelices el Chico Spain), May 2011, PubliCan, Ediciones de la Universitad de Cantabria (2012), ISBN , WHO Handbook on Indoor Radon: A Public Health Perspective, WHO Press, Geneva, ICRP, Protection against Radon-222 at Home and at Work, Publ.65, Pergamon Press, Oxford, 1994.

INTERNATIONAL INTERCOMPARISON EXERCISE ON NATURAL RADIATION MEASUREMENTS UNDER FIELD CONDITIONS (IFC11) *

INTERNATIONAL INTERCOMPARISON EXERCISE ON NATURAL RADIATION MEASUREMENTS UNDER FIELD CONDITIONS (IFC11) * INTERNATIONAL INTERCOMPARISON EXERCISE ON NATURAL RADIATION MEASUREMENTS UNDER FIELD CONDITIONS (IFC11) * BOTOND PAPP 1, ALEXANDRA CUCOŞ (DINU) 1*, MIRCEA MOLDOVAN 1, ROBERT BEGY 1, TIBERIU DICU 1, DAN

More information

INTERNATIONAL INTERCOMPARISON EXERCISE OF ACTIVE RADON DEVICES AND PASSIVE DETECTORS AT THE FIRST EAST EUROPEAN RADON SYMPOSIUM (FERAS 2012)

INTERNATIONAL INTERCOMPARISON EXERCISE OF ACTIVE RADON DEVICES AND PASSIVE DETECTORS AT THE FIRST EAST EUROPEAN RADON SYMPOSIUM (FERAS 2012) INTERNATIONAL INTERCOMPARISON EXERCISE OF ACTIVE RADON DEVICES AND PASSIVE DETECTORS AT THE FIRST EAST EUROPEAN RADON SYMPOSIUM ( 2012) BOTOND PAPP *, CONSTANTIN COSMA, ALEXANDRA CUCOŞ (DINU) Environmental

More information

BRUNILDA DACI INSTITUTE OF APPLIED NUCLEAR PHYSICS TIRANA-ALBANIA. KOZETA BODE Responsible person for Radon Measurement in Albania

BRUNILDA DACI INSTITUTE OF APPLIED NUCLEAR PHYSICS TIRANA-ALBANIA. KOZETA BODE Responsible person for Radon Measurement in Albania BRUNILDA DACI INSTITUTE OF APPLIED NUCLEAR PHYSICS TIRANA-ALBANIA KOZETA BODE Responsible person for Radon Measurement in Albania Tallinn, Estonia, 23-27 May 2016 1 CONTENT OF THE PRESENTATION INTRODUCTION

More information

Radon situation in workplaces in Romania. Ioan Encian National Commission for Nuclear Activities Control - Bucharest

Radon situation in workplaces in Romania. Ioan Encian National Commission for Nuclear Activities Control - Bucharest Radon situation in workplaces in Romania Ioan Encian National Commission for Nuclear Activities Control - Bucharest Radon in workplaces - Systematic measurements of indoor radon only in workplaces from

More information

HISTORY OF SOIL-GAS RADON CONCENTRATION MEASUREMENTS IN THE CZECH REPUBLIC

HISTORY OF SOIL-GAS RADON CONCENTRATION MEASUREMENTS IN THE CZECH REPUBLIC HISTORY OF SOIL-GAS RADON CONCENTRATION MEASUREMENTS IN THE CZECH REPUBLIC Martin Neznal & Matěj Neznal RADON v.o.s. Novákových 6, 180 00 Praha 8, Czech Republic radon@comp.cz www.radon.eu LATIN AMERICAN

More information

METHODOLGY FOR RADON PRESENCE INVESTIGATION IN MINE GALLERIES. CASE STUDY: BĂIŢA BIHOR REPOSITORY

METHODOLGY FOR RADON PRESENCE INVESTIGATION IN MINE GALLERIES. CASE STUDY: BĂIŢA BIHOR REPOSITORY U.P.B. Sci. Bull., Series C, Vol. 76, Iss. 4, 2014 ISSN 2286-3540 METHODOLGY FOR RADON PRESENCE INVESTIGATION IN MINE GALLERIES. CASE STUDY: BĂIŢA BIHOR REPOSITORY Alin-Ionuţ PETRESCU 1, Ilie Constantin

More information

Design and Fabrication of New Radon Chamber for Radon Calibration Factor of Measurement

Design and Fabrication of New Radon Chamber for Radon Calibration Factor of Measurement International Journal of Scientific & Engineering Research, Volume 3, Issue 10, October-2012 1 Design and Fabrication of New Radon Chamber for Radon Calibration Factor of Measurement Murtadha S. Al-Nafiey,*

More information

MetroRADON project and its potential impact on mitigation practices Dobromir Pressyanov Sofia University St. Kliment Ohridski Bulgaria

MetroRADON project and its potential impact on mitigation practices Dobromir Pressyanov Sofia University St. Kliment Ohridski Bulgaria MetroRADON project and its potential impact on mitigation practices Dobromir Pressyanov Sofia University St. Kliment Ohridski Bulgaria Wolfgang Ringer Austrian Agency for Health and Food Safety (AGES)

More information

RADON CONCENTRATIONS AFFECTED BY DIFFERENT FACTORS IN TWO OFFICE BUILDINGS. Raimo Halonen, Pirjo Korhonen, Pentti Kalliokoski and Helmi Kokotti

RADON CONCENTRATIONS AFFECTED BY DIFFERENT FACTORS IN TWO OFFICE BUILDINGS. Raimo Halonen, Pirjo Korhonen, Pentti Kalliokoski and Helmi Kokotti Radon in the Living Environment, 25 RADON CONCENTRATIONS AFFECTED BY DIFFERENT FACTORS IN TWO OFFICE BUILDINGS Raimo Halonen, Pirjo Korhonen, Pentti Kalliokoski and Helmi Kokotti Department of Environmental

More information

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points Topic 4 - Audio 46 Key Points : Measures taken to increase confidence in results. Quality Assurance: Program that assures that measures are being done and in a timely manner. Precision: How close measurements

More information

Radon and Thoron Measurements at Special Underground Circumstances

Radon and Thoron Measurements at Special Underground Circumstances Radon and Thoron Measurements at Special Underground Circumstances Tibor Kovács a*, Norbert Kávási b, Csaba Németh c, János Somlai a, Tamás Vigh d, Gábor Szeiler a, and Shinji Tokonami e, Hiroyuki Takahashi

More information

Sensitivity to Thoron on Passive Radon Detectors

Sensitivity to Thoron on Passive Radon Detectors Sensitivity to Thoron on Passive Radon Detectors S. Tokonami 1, H. Yonehara 1, T. Sanada 2, M. Yang 3, M. Furukawa 1 and Y. Yamada 1 1 National Institute of Radiological Sciences, Chiba 263-8555, Japan

More information

A new passive integrating detector for measurement of individual radon exposure at working places.

A new passive integrating detector for measurement of individual radon exposure at working places. A new passive integrating detector for measurement of individual radon exposure at working places. G. Sciocchetti, G. Cotellessa, E. Soldano, M. Pagliari and A. Ceccatelli (*) ENEA-ION-IRP, Centro Ricerche

More information

ENVIRONMENTAL RADON MONITORING IN DWELLINGS NEAR THE RADIOACTIVE SITES

ENVIRONMENTAL RADON MONITORING IN DWELLINGS NEAR THE RADIOACTIVE SITES ENVIRONMENTAL RADON MONITORING IN DWELLINGS NEAR THE RADIOACTIVE SITES B.S BAJWA and H.S. VIRK Deptt. of Physics, Guru Nanak Dev University Amritsar-143005, India. In view of the of the fact that radon

More information

CURRENT INDOOR RADON SITUATION IN LITHUANIA

CURRENT INDOOR RADON SITUATION IN LITHUANIA CURRENT INDOOR RADON SITUATION IN LITHUANIA Rima Ladygienė, PhD Radiation Protection Centre LEGISLATION National policy on radon is based on the appropriate recommendations of International Commission

More information

RADON SURVEY IN KALAMATA (GREECE) Medicine, London SW7 2AZ U.K. Greece. Republic

RADON SURVEY IN KALAMATA (GREECE) Medicine, London SW7 2AZ U.K. Greece. Republic Radon in the Living Environment, 132 RADON SURVEY IN KALAMATA (GREECE) A. Geranios 1, M. Kakoulidou 1, Ph. Mavroidi 2, M. Moschou 3, S. Fischer 4, I. Burian 5 and J. Holecek 5 1 Nuclear and Particle Physics

More information

STUDY #3 IN A SERIES OF REPORTS ON RADON IN BC HOMES. Castlegar: COMMUNITY-WIDE RADON TESTING RESULTS AS PART OF ITS. PROGRAm

STUDY #3 IN A SERIES OF REPORTS ON RADON IN BC HOMES. Castlegar: COMMUNITY-WIDE RADON TESTING RESULTS AS PART OF ITS. PROGRAm STUDY #3 IN A SERIES OF REPORTS ON RADON IN BC HOMES Castlegar: COMMUNITY-WIDE RADON TESTING RESULTS AS PART OF ITS PROGRAm BC Lung Association The British Columbia Lung Association (BCLA) is one of the

More information

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date: LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: ALPHA TRACK Method Number: ELAP method number 7035 SOP Number: Revision Number: SOP Date: Personnel / Data Records observed: Page 1 of 6 RADON IN AIR

More information

Designing and construction of a new radon calibration facility in Romania

Designing and construction of a new radon calibration facility in Romania Designing and construction of a new radon calibration facility in Romania Aurelian Luca a*, Leonardo Şerbina a, Carmen Varlam b, Maria Sahagia a, Dorin Schitea b, Ionuţ Făurescu b, Octavian Sima a,c, Mihail-Răzvan

More information

SEASONAL VARIATION OF RADON CONCENTRATION - MEASUREMENTS IN SOME EUROPEAN COUNTRIES

SEASONAL VARIATION OF RADON CONCENTRATION - MEASUREMENTS IN SOME EUROPEAN COUNTRIES Radon in the Living Environment, 169 SEASONAL VARIATION OF RADON CONCENTRATION - MEASUREMENTS IN SOME EUROPEAN COUNTRIES Gilbert Jönsson a, Carmen Baixeras b, Lluis Font b, Diego Albarracin b, Giuseppe

More information

PH.D. THESIS (SUMMARY)

PH.D. THESIS (SUMMARY) BABEŞ-BOLYAI UNIVERSITY, CLUJ-NAPOCA FACULTY OF ENVIRONMENTAL SCIENCE PH.D. THESIS (SUMMARY) USE OF SOLID STATE TRACK DETECTORS IN RADON STUDY: RESIDENTIAL AND INSTITUTIONAL EXPOSURE Scientific coordinator:

More information

THE NATIONAL RADON SURVEY IN IRELAND. S.G. Fennell, G.M. Mackin, J.S. Madden and A.T. McGarry

THE NATIONAL RADON SURVEY IN IRELAND. S.G. Fennell, G.M. Mackin, J.S. Madden and A.T. McGarry Radon in the Living Environment, 136 THE NATIONAL RADON SURVEY IN IRELAND S.G. Fennell, G.M. Mackin, J.S. Madden and A.T. McGarry Radiological Protection Institute of Ireland, 3 Clonskeagh Square, Clonskeagh

More information

CURRENT STATE OF THE ART IN MEASURING ENVIRONMENTAL RADON. Abstract

CURRENT STATE OF THE ART IN MEASURING ENVIRONMENTAL RADON. Abstract CURRENT STATE OF THE ART IN MEASURING ENVIRONMENTAL RADON A.C. George and N. Bredhoff Radon Testing Corporation of America Elmsford, New York Abstract According to the US EPA, radon is the leading cause

More information

Ohio Department of Health, Bureau of Environmental Health and Radiation Protection, Radon Licensing Program. School Radon Testing Checklist

Ohio Department of Health, Bureau of Environmental Health and Radiation Protection, Radon Licensing Program. School Radon Testing Checklist Ohio Department of Health, Bureau of Environmental Health and Radiation Protection, Radon Licensing Program School Radon Testing Checklist Purpose: This checklist has been prepared to provide school employees

More information

A study of Indoor Radon / Thoron Levels in Some Dwellings by using Solid State Nuclear Track Detectors

A study of Indoor Radon / Thoron Levels in Some Dwellings by using Solid State Nuclear Track Detectors International Journal of Pure and Applied Physics ISSN 0973-1776 Volume 6, Number 2 (2010), pp. 157 164 Research India Publications http://www.ripublication.com/ijpap.htm A study of Indoor Radon / Thoron

More information

International Requirements for the Control of Radon

International Requirements for the Control of Radon Tenth Irish National Radon Forum Thursday 17 January 2013 International Requirements for the Control of Radon Trevor Boal, -NSRW International Atomic Energy Agency Content Safety Standards Requirements

More information

Co-60 irradiator for therapy level calibrations at SSDLs

Co-60 irradiator for therapy level calibrations at SSDLs SPECIFICATION Co-60 irradiator for therapy level calibrations at SSDLs Prepared by: Igor Gomola, Technical Officer for TC Project ISR6021 Date: 2014-Aug-04, Rev.08 Page 1 1. Scope and Background This document

More information

Radon in thermal waters and radon risk in chosen thermal water spas in V4 countries - preliminary results

Radon in thermal waters and radon risk in chosen thermal water spas in V4 countries - preliminary results Radon in thermal waters and radon risk in chosen thermal water spas in V countries - preliminary results Karol Holý, Pavol Blahušiak, Dominik Grządziel, Tibor Kovács, Krzysztof Kozak, Jadwiga Mazur, Monika

More information

European Commission approach with regard to radon

European Commission approach with regard to radon European Commission approach with regard to radon Åsa Wiklund National Expert in DG TREN/H.4 Radiation Protection EUROPEAN COMMISSION 1 Radon at the European Commission DG TREN DG RTD DG SANCO Joint Research

More information

C-NRPP Quality Assurance Guidance for Radon Test Devices

C-NRPP Quality Assurance Guidance for Radon Test Devices C-NRPP Quality Assurance Guidance for Radon Test Devices Table of Contents: 1. Purpose 2. Definitions 3. Quality Assurance Plan 4. Calibration 5. Spikes/Performance Tests 6. Duplicates 7. Blanks 8. Cross-Checks

More information

Via Umberto Giordano, Padova Tel Fax VERSIONS ACCURACY

Via Umberto Giordano, Padova Tel Fax VERSIONS ACCURACY DOWNLOADS DESCRIPTION BATTERY LIFE Approximately 1.5 years of continuous monitoring 3 replaceable AAA batteries DISPLAY 1-day, 7-day, and long-term average radon level FUNCTIONS Reset button Mode button

More information

Outdoor radon concentration in China

Outdoor radon concentration in China NUKLEONIKA 2016;61(3):373 378 doi: 10.1515/nuka-2016-0062 ORIGINAL PAPER Outdoor radon concentration in China Qifan Wu, Ziqiang Pan, Senlin Liu, Chunhong Wang Abstract. A nationwide survey was conducted

More information

IFIN-HH, Hadron Physics Department infrastructure for ALICE TPC upgrade

IFIN-HH, Hadron Physics Department infrastructure for ALICE TPC upgrade Hadron Physics Department IFIN-HH, Hadron Physics Department infrastructure for ALICE TPC upgrade M. Petris, M. Petrovici, V. Aprodu, D. Bartos, A. Bercuci, Gh. Caragheorgheopol, V. Catanescu, V. Duta,

More information

A new personal dosemeter for the individual monitoring of exposure to radon gas

A new personal dosemeter for the individual monitoring of exposure to radon gas A new personal dosemeter for the individual monitoring of exposure to radon gas Rosabianca Trevisi a*, Paolo Orlando b, Giuseppe Arcovito b, Francesco Cardellini c, Elisabetta Fonti b, Claudia Orlando

More information

C-NRPP Quality Control and Quality Assurance Manual for Radon Sampling and Analysis conducted by Radon Measurement Professionals and Laboratories

C-NRPP Quality Control and Quality Assurance Manual for Radon Sampling and Analysis conducted by Radon Measurement Professionals and Laboratories C-NRPP Quality Control and Quality Assurance Manual for Radon Sampling and Analysis conducted by Radon Measurement Professionals and Laboratories October 2018 C-NRPP/PNCR-C 1 (855) 722-6777 c-nrpp.ca Canadian

More information

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc. Commercial Radon Survey Report Client: Community Consolidated School District 181 Site Address: Monroe School 210 N Madison Hinsdale, IL 60521 Survey Date: May 7, 2012 to May 9, 2012 Initial Test RDS-R-002

More information

Sergey Kiselev. SRC Federal Medical Biophysical Center

Sergey Kiselev. SRC Federal Medical Biophysical Center Sergey Kiselev SRC Federal Medical Biophysical Center Uranium Thorium 1940s -uranium/thorium geological maps. Epidemiological studies U-mine cohort studies Place Zheltoreche nsk Uchkuduk Country Type of

More information

RADPAR: Radon Prevention and Remediation ( )

RADPAR: Radon Prevention and Remediation ( ) RADPAR: Radon Prevention and Remediation (2009 2012) Prof. John G. Bartzis University of Western Macedonia Greece RADPAR is funded by : Executive Agency for Health and Consumers (EAHC) of Directorate General

More information

What you need to know

What you need to know What you need to know What RADON is The health effects How to test your home How to reduce your risk Protect your health. Test your home. www.regionofwaterloo.ca/radon RADON information What is radon?

More information

RADON TESTING: HEALTH GUIDELINES

RADON TESTING: HEALTH GUIDELINES RADON TESTING: HEALTH GUIDELINES What is the Health Canada recommended action level for radon mitigation? The Health Canada recommended action level [also known as the reference level] is 200 Bq/m 3. What

More information

National strategy for radon in Norway

National strategy for radon in Norway National strategy for radon in Norway Jelena Mrdakovic Popic, Maria Larsson and Bård Olsen Radon national action plan workshop Paris, 30. sept. -2. oct. 2014 Content Radon in Norway National strategi for

More information

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc. Commercial Radon Survey Report Client: Community Consolidated School District 181 Site Address: Prospect School 130 N Prospect Clarendon Hills, IL 60514 Survey Date: April 23, 2012 to April 25, 2012 Initial

More information

Intercomparison s working group:

Intercomparison s working group: Radon passive detectors intercomparison in the field: radiometric characterisation of the sites Enrico Chiaberto - ARPA Piemonte Intercomparison s working group: Filippo Berlier, Francesco Cardellini,

More information

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc. Commercial Radon Survey Report Client: Community Consolidated School District 181 Site Address: Walker School 120 S Walker Clarendon Hills, IL 60514 Survey Date: April 25, 2012 to April 27, 2012 Initial

More information

Paul Kotrappa, Ph.D. and Carolyn Allen. Rad Elec Inc., 5714-C Industry Lane, Frederick, MD USA

Paul Kotrappa, Ph.D. and Carolyn Allen. Rad Elec Inc., 5714-C Industry Lane, Frederick, MD USA 177 REVIEW OF QA\QC ASPECTS OF ELECTRET ION CHAMBERS- MANUFACTURING PRACTICES AND PERFORMANCE IN WORLDWIDE INTER-COMPARISON EXERCISES IN THE PAST EIGHT YEARS Paul Kotrappa, Ph.D. and Carolyn Allen Rad

More information

Radon Detection Specialists, Inc. Love the Lungs You re With

Radon Detection Specialists, Inc. Love the Lungs You re With 630-325-4443 800-244-4242 kws@radonresults.com Commercial Radon Survey Report Client: Pleasantdale School District 107 8100 School Street La Grange, Illinois 60525 Survey Date: October 20 2014 to October

More information

Radon Detection Specialists, Inc. Love the Lungs You re With

Radon Detection Specialists, Inc. Love the Lungs You re With 630-325-4443 800-244-4242 kws@radonresults.com Commercial Radon Survey Report Client: Pleasantdale School District 107 8100 School Street La Grange, Illinois 60525 Survey Date: August 27, 2014 to August

More information

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc. Commercial Survey Report Client: Community Consolidated School District 181 Site Address: Elm School 6010 S Elm St Hinsdale, IL 60521 Survey Date: April 9, 2012 to April 11, 2012 Initial Test RDS-R-002

More information

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc. Commercial Radon Survey Report Client: Community Consolidated School District 181 Site Address: The Lane School 500 N Elm St Hinsdale, IL 60521 Survey Date: April 17, 2012 to April 19, 2012 Initial Test

More information

Certificate of Completion

Certificate of Completion Love the Lungs You re With 630-325-4443 800-244-4242 Certificate of Completion Every parent or guardian is notified that this facility has performed radon measurements to ensure the health and safety of

More information

Bethel School District Radon Testing Plan

Bethel School District Radon Testing Plan The 2015 Oregon Legislature passed House Bill (HB) 2931 so that elevated radon levels in Oregon schools would be known. House Bill 2931 later became Oregon Revised Statute (ORS) 332.166-167. As directed

More information

Radon monitoring system in the Kamioka mine

Radon monitoring system in the Kamioka mine Radon monitoring system in the Kamioka mine Guillaume Pronost on behalf of the Super-Kamiokande collaboration Kamioka Observatory, ICRR, The University of Tokyo JPS Miyazaki conference, September 21th

More information

Comprehensive Short-Term Radon Survey Report

Comprehensive Short-Term Radon Survey Report Environmental Works, LLC 2634 SE Steele St. Portland, OR. 97202 Phone: 503-719-6715 Fax: 503-972-1866 Email: Sebastian@eworksnw.com Comprehensive Short-Term Radon Survey Report Test Performed At: Trillium

More information

R&D for the improvement of O&M in CSP plants. Dr. Marcelino Sánchez. - November,

R&D for the improvement of O&M in CSP plants. Dr. Marcelino Sánchez. - November, R&D for the improvement of O&M in CSP plants. Dr. Marcelino Sánchez - November, 2015 - í n d i c e 1 Need of R&D for O&M improvement in CSP Plants 2 Current R&D activities in O&M improvement carried out

More information

Standard ECMA th Edition - December Declared Noise Emission Values of Information Technology and Telecommunications Equipment

Standard ECMA th Edition - December Declared Noise Emission Values of Information Technology and Telecommunications Equipment Standard ECMA-109 4 th Edition - December 1996 Standardizing Information and Communication Systems Declared Noise Emission Values of Information Technology and Telecommunications Equipment Phone: +41 22

More information

Radon Measurements in Argentina

Radon Measurements in Argentina AUTORIDAD REGULATORIA NUCLEAR (ARN) Radon Measurements in Argentina Juan Pablo Bonetto a, Analia Canoba, Fabio López Gerencia de Apoyo Científico técnico ARN a E-mail: jbonetto@arn.gob.ar Introduction

More information

RAMSES: THE LHC RADIATION MONITORING SYSTEM FOR THE ENVIRONMENT AND SAFETY

RAMSES: THE LHC RADIATION MONITORING SYSTEM FOR THE ENVIRONMENT AND SAFETY 10th ICALEPCS Int. Conf. on Accelerator & Large Expt. Physics Control Systems. Geneva, 10-14 Oct 2005, TH3B.1-3O (2005) RAMSES: THE LHC RADIATION MONITORING SYSTEM FOR THE ENVIRONMENT AND SAFETY G. Segura

More information

Certificate of Completion

Certificate of Completion Love the Lungs You re With 630-325-4443 800-244-4242 Certificate of Completion Every parent or guardian is notified that this facility has performed radon measurements to ensure the health and safety of

More information

Certificate of Completion

Certificate of Completion Love the Lungs You re With 630-325-4443 800-244-4242 Certificate of Completion Every parent or guardian is notified that this facility has performed radon measurements to ensure the health and safety of

More information

Development of high sensitivity radon detectors

Development of high sensitivity radon detectors Nuclear Instruments and Methods in Physics Research A 421 (1999) 334 341 Development of high sensitivity radon detectors Y. Takeuchi *, K. Okumura, T. Kajita, S. Tasaka, H. Hori, M. Nemoto, H. Okazawa

More information

Comprehensive applications of the gas flow proportional counters for Radiological Surveillance

Comprehensive applications of the gas flow proportional counters for Radiological Surveillance Comprehensive applications of the gas flow proportional counters for Radiological Surveillance D.A.R.Babu, Anand Raman, Ashokkumar P and D.N.Sharma Radiation Safety Systems Division, Bhabha Atomic Research

More information

835 S. Canyon Blvd., John Day, OR 97845 Phone: (541) 575-1349 Fax: (541) 575-3601 Robert Waltenburg-Superintendent waltenburgr@grantesd.k12.or.us Stacie Holmstrom Deputy Clerk holmstroms@grantesd.k12.or.us

More information

ELECTRICAL IMPEDANCE TOMOGRAPHY

ELECTRICAL IMPEDANCE TOMOGRAPHY Appendix I ELECTRICAL IMPEDANCE TOMOGRAPHY Philip Church, Neptec Design Group BASIC PRINCIPLES Electrical impedance tomography (EIT) is a technology developed to image the electrical conductivity distribution

More information

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting Method Number: ELAP method number 7036 SOP Number: Revision Number:

More information

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science The world leader in serving science Instrumentation Post RDD Event Urban Reoccupancy James P. Menge PE Perception In the aftermath of a radiological emergency the public will see radiation and its potential

More information

Radon in (Greek) workplaces GREECE

Radon in (Greek) workplaces GREECE Radon in (Greek) workplaces GREECE Maria Kolovou Department of Environmental Radioactivity Control www.gaec.gr Measurement of radon Radon measurements are performed according to the terms of ISO 11665

More information

RADON PLAN. Eugene School District 4J Facilities Management 715 West Fourth Avenue Eugene, OR

RADON PLAN. Eugene School District 4J Facilities Management 715 West Fourth Avenue Eugene, OR RADON PLAN The 2015 Legislature passed House Bill (HB) 2931 so that if elevated radon levels in Oregon schools existed they would be known. House Bill 2931 later became Oregon Revised Statute (ORS) 332.166-167.

More information

Department of State Health Services

Department of State Health Services Page I of 10 Pursuant to the Texas Radiation Control Act and Texas (Agency) regulations on radiation, and in reliance on statements and representations heretofore made by the licensee, a license is hereby

More information

Environmental radioactivity surveillance system of ANPA

Environmental radioactivity surveillance system of ANPA NUKLEONIKA 2001;46(4):137 141 PROCEEDINGS Environmental radioactivity surveillance system of ANPA Anna Alonzi, Sergio Mancioppi, Massimo Notaro, Paolo Zeppa Abstract No nuclear power station are operative

More information

Detectors used in the intercomparison

Detectors used in the intercomparison Detectors used in the intercomparison The second radon-in-field international intercomparison for passive measurement devices: dwellings and workplaces 21 22 september 2017 Campus Bovisa Politecnico di

More information

Radon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 417 Fifth Street Aurora, Illinois 60505 Survey Dates: May 9, 2018 thru May 11, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

J. R. Qualey III, L. Desmarais, J. Pratt Simplex Time Recorder Co., 100 Simplex Drive, Westminster, MA 01441

J. R. Qualey III, L. Desmarais, J. Pratt Simplex Time Recorder Co., 100 Simplex Drive, Westminster, MA 01441 J. R. Qualey III, L. Desmarais, J. Pratt Simplex Time Recorder Co., 100 Simplex Drive, Westminster, MA 01441 Response-Time Comparisons of Ionization and Photoelectric/Heat Detectors 1. Introduction Despite

More information

Guide for Radon Measurements in Residential Dwellings (Homes)

Guide for Radon Measurements in Residential Dwellings (Homes) Guide for Radon Measurements in Residential Dwellings (Homes) Health Canada is the federal department responsible for helping Canadians maintain and improve their health. We assess the safety of drugs

More information

Radon Measurement Survey Report. Krug Elementary School 240 Melrose Avenue Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Krug Elementary School 240 Melrose Avenue Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 240 Melrose Avenue Aurora, Illinois 60505 Survey Dates: May 1, 2018 thru May 3, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate Environmental and Food Measurements Lab & Individual monitoring lab Yemen Republic Population : 22 million

More information

Radon Testing and Reporting Plan. Tillamook School District #9 Tillamook, Oregon

Radon Testing and Reporting Plan. Tillamook School District #9 Tillamook, Oregon Radon Testing and Reporting Plan Tillamook School District #9 Tillamook, Oregon Introduction: In 2015, the Oregon Legislature passed Oregon Revised Statute (ORS) 332.166-167 which, in part, requires school

More information

INTERNATIONAL JOURNAL OF RESEARCH SCIENCE & MANAGEMENT

INTERNATIONAL JOURNAL OF RESEARCH SCIENCE & MANAGEMENT [Kim* et al., 4(2): February, 17] ISSN: 234-97 PERFORMANCE IMPROVEMENT OF RADON COUNTERS 1 Yong-Cheol Kim, *2 Gyu-Sik Kim 1,2 Professor, Dept. of Electrical and Computer Eng., University of Seoul, Korea

More information

Guidance Document Design, Testing and Performance of Exposure Devices RD/GD-352

Guidance Document Design, Testing and Performance of Exposure Devices RD/GD-352 Guidance Document Design, Testing and Performance of Exposure Devices RD/GD-352 December 2010 Design, Testing and Performance of Exposure Devices Draft Guidance Document RD/GD-352 Published by the Canadian

More information

THE EFFECT OF BUILDING CODES AND HOUSE AGE ON RADON CONCENTRATIONS IN MINNESOTA

THE EFFECT OF BUILDING CODES AND HOUSE AGE ON RADON CONCENTRATIONS IN MINNESOTA THE EFFECT OF BUILDING CODES AND HOUSE AGE ON RADON CONCENTRATIONS IN MINNESOTA Daniel J. Steck Physics Department, St. John's University Collegeville, MN 5632 1 ABSTRACT Many public radon reduction programs

More information

Environmental Radiation Monitoring System

Environmental Radiation Monitoring System Environmental Radiation Monitoring System Toshihiro Takagi Osamu Kimura Atsushi Minagoshi 1. Introduction In order to ascertain conditions near the perimeter of a supervised area at a nuclear power plant

More information

David F. Metzger 121 N. Leavitt Rd. #313, Amherst, OH Certified Radon Tester Ohio License #: RS340 & RC213; NRPP ID#: RT

David F. Metzger 121 N. Leavitt Rd. #313, Amherst, OH Certified Radon Tester Ohio License #: RS340 & RC213; NRPP ID#: RT Contract #: per D. Boyer/ C. Fredrichs for Radon Testing Services Report of Radon Measurement Survey Date: November 16, 2018 Site: Shaker Schools, Shaker Heights, Ohio Onaway Elementary School and Woodbury

More information

Assessment of Radon-222 Concentrations in Buildinps, Building Materials, Water and Soil in Jordan

Assessment of Radon-222 Concentrations in Buildinps, Building Materials, Water and Soil in Jordan Assessment of Radon-222 Concentrations in Buildinps, Building Materials, Water and Soil in Jordan Mahmoud Kullab Physics Department, Yarmouk University, Irbid 2 1 1-63, Jordan E-mail: mkullab@yu.edu.jo

More information

Radon Measurement Survey Report. Oak Park Elementary School 1200 Front Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Oak Park Elementary School 1200 Front Street Aurora, Illinois Prepared For: Radon Measurement Survey Report Site:July 5, 2018 1200 Front Street Aurora, Illinois 60505 Survey Dates: May 9, 2018 thru May 11, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora,

More information

EC - RADON Latest strategies and draft regulations

EC - RADON Latest strategies and draft regulations EC - RADON Latest strategies and draft regulations European Commission Radiation Protection Participation in EARST WORKSHOP 2013, International and National RADON Regulations & Strategies EC-DG-ENER-D3

More information

A CONTINUOUS RADON MONITORING SYSTEM BASED ON A SOLID- STATE SILICON DETECTOR

A CONTINUOUS RADON MONITORING SYSTEM BASED ON A SOLID- STATE SILICON DETECTOR Applying the logo environment: learning, doing and discovering through computerized learning projects, M. A. Murray-Lasso, 3-18 A CONTINUOUS RADON MONITORING SYSTEM BASED ON A SOLID- STATE SILICON DETECTOR

More information

Radon Measurement Survey Report. Rollins Elementary School 950 Kane Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Rollins Elementary School 950 Kane Street Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 950 Kane Street Aurora, Illinois 60505 Survey Dates: May 15, 2018 thru May 18, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

RADON: IS IT IN YOUR HOME?

RADON: IS IT IN YOUR HOME? RADON: IS IT IN YOUR HOME? WHAT IS RADON? Radon is a radioactive gas that occurs naturally when the uranium in soil and rock breaks down. It is invisible, odourless and tasteless. When radon is released

More information

Design, Testing and Performance of Exposure Devices RD/GD-352

Design, Testing and Performance of Exposure Devices RD/GD-352 Design, Testing and Performance of Exposure Devices RD/GD-352 January 2012 Design, Testing and Performance of Exposure Devices RD/GD-352 Minister of Public Works and Government Services Canada (PWGSC)

More information

Radon Reference Facility at Bowser-Morner, Inc. AMUG Meeting Las Vegas May 4, 2010 Phillip H. Jenkins, PhD, CHP

Radon Reference Facility at Bowser-Morner, Inc. AMUG Meeting Las Vegas May 4, 2010 Phillip H. Jenkins, PhD, CHP Radon Reference Facility at Bowser-Morner, Inc. AMUG Meeting Las Vegas May 4, 2010 Phillip H. Jenkins, PhD, CHP Radon Reference Facility What We Do Calibration of Rn and RDP measuring devices Spiking of

More information

Relevant Radon properties

Relevant Radon properties Relevant Radon properties Radon is a natural gas and has a half life of 3.8 days. This means that if a box was full of radon gas, half of it would have decayed into something else after 3.8 days. It has

More information

THE RELIABILITY OF RADON REDUCTION TECHNIQUES. CB Howarth

THE RELIABILITY OF RADON REDUCTION TECHNIQUES. CB Howarth Radon in the Living Environment, 052 THE RELIABILITY OF RADON REDUCTION TECHNIQUES CB Howarth National Radiological Protection Board Chilton, Didcot, Oxon, OX11 0RQ, UK Tel: +44 1235 822796, Fax: +44 1235

More information

RADON LAZERWEB SERVICES

RADON LAZERWEB SERVICES RADON LAZERWEB SERVICES WWW.LAZERWEBSITES.COM Contents Overview...2 Radon is estimated to cause thousands of lung cancer deaths in the U.S. each year...2 Radon is a cancer causing, radioactive gas...2

More information

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date: LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: ELECTRET by Voltametry Method Number: ELAP method number 7034 SOP Number: Revision Number: SOP Date: Personnel / Data Records observed: General LLD:

More information

Radon Measurement Survey Report. Waldo Middle School 56 Jackson Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Waldo Middle School 56 Jackson Street Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 56 Jackson Street Aurora, Illinois 60505 Survey Dates: May 8, 2018 thru May 10, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

Status of Texas active target data manager development. S. Ahn, G.V. Rogachev, E. Koshchiy, J. Hooker, and S. Upadhiajula

Status of Texas active target data manager development. S. Ahn, G.V. Rogachev, E. Koshchiy, J. Hooker, and S. Upadhiajula Status of Texas active target data manager development S. Ahn, G.V. Rogachev, E. Koshchiy, J. Hooker, and S. Upadhiajula In order to address questions in nuclear structure, nuclear reactions and nuclear

More information

Application Note. Application Note for BAYEX

Application Note. Application Note for BAYEX Application Note Application Note for BAYEX Preface This application note provides the user a more detailed description of the Bayesian statistical methodology available in Version 8.05 and above, of the

More information

Remote Monitoring of Offshore Structures using Acoustic Emission.

Remote Monitoring of Offshore Structures using Acoustic Emission. 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic Remote Monitoring of Offshore Structures using Acoustic Emission. More Info at Open Access Database

More information

Request for tender regarding the validation of ammonia testing methods as supplement to pren 16516

Request for tender regarding the validation of ammonia testing methods as supplement to pren 16516 Secretariat: Nederlands Normalisatie-instituut doc.nr. Vlinderweg 6 P.O. Box 5059 2623 AX DELFT 2600 GB DELFT date The Netherlands The Netherlands 2015-10-01 Telephone: +31 15 2 690 280 CEN/TC 351 N 0644

More information

Fundamentals is subdivided into Sources of Radiation, Biological Effects, Mathematics, Chemistry, Physics, and Units and Terminology.

Fundamentals is subdivided into Sources of Radiation, Biological Effects, Mathematics, Chemistry, Physics, and Units and Terminology. NRRPT Exam Review Class - an intensive 5-day class designed to prepare the candidate to successfully pass the NRRPT Exam. The course concentrates on the basic tools the candidate needs to successfully

More information

A Study into the Standardization of Using Fire Detectors in Rail Vehicles for China

A Study into the Standardization of Using Fire Detectors in Rail Vehicles for China Available online at www.sciencedirect.com Procedia Engineering 52 ( 2013 ) 240 244 A Study into the Standardization of Using Fire Detectors in Rail Vehicles for China LIU Xiao-lu *, WANG Wen-qing Shenyang

More information