Field Certification Certificate of Compliance

Size: px
Start display at page:

Download "Field Certification Certificate of Compliance"

Transcription

1 2 Field Certification Certificate of Compliance Certificate: Master Contract: Project: Issued to: SpectraSensors, Inc Arrow Route Rancho Cucamonga, CA USA Attention: Mr. Paul Silva The products listed below are eligible to bear CSA Field Certification Labels, bearing the CSA Mark shown with adjacent indicators 'C' and 'US'. Issued by: Rich Masek, P.E. PRODUCTS CLASS : PROCESS CONTROL EQUIPMENT For Hazardous Locations CLASS : PROCESS CONTROL EQUIPMENT For Hazardous Locations CSA Field Certification Label(s) issued: from serial numbers C to C Class I; Division 1; Group C, D; T6 Model HCD4000 Hydrocarbon Dew Point Analyzer, Rated V, Hz, 150 VA, MWP: 1500 PSI. S/N CSA Label S/N CSA Label S/N CSA Label 5161 C C C C C C C Note: It is the responsibility of the user to install any necessary secondary seals on the conduit.

2 Page 2 Certificate: Project: Master Contract: Date: APPLICABLE REQUIREMENTS C Canadian Electrical Code Part I. C22.2 No 0 M1991 General Requirements Canadian Electrical Code Part II. C22.2 No. 30 M1986 Explosion-Proof Enclosures for Use in Class I Hazardous Locations C22.2 No 142 M1987 Process Control Equipment. NFPA 70:2008 National Electrical Code UL 916 Ed 4 UL 1203:2006 Energy Management Equipment Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Locations MARKINGS Submittor s name, trademark Model designation. Complete electrical rating (Volts, Hertz, and VA). Serial number. Maximum Working Pressure (MAX 1500 PSIG). Hazardous Location designations. CAUTION: KEEP COVERS TIGHT WHILE CIRCUITS ARE ALIVE or the equivalent. INSTALL CONDUIT SEALS WITHIN 3 INCHES OF ENCLOSURE Note - Jurisdictions in Canada may require these markings to also be provided in French language. It is the responsibility of the manufacturer to provide bilingual marking, where applicable, in accordance with the requirements of the Provincial Regulatory Authorities. It is the responsibility of the manufacturer to determine this requirement and have bilingual wording added to the "Markings". METHOD OF MARKING: The markings appear on a laminated paper nameplate that is mounted behind the window of the enclosure.

3 Supplement to Certificate of Compliance Certificate: Master Contract: The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Project Date Description Product Certification History Original Field Certification. Field Certification Labels issued: Serial numbers C to C (total of 7 labels) Report issued.

4 Descriptive and Test Report Edition 1: ; Project Cleveland Issued by Rich Masek, P.E. MASTER CONTRACT: Contents: Certificate of Compliance 2 pages Supplement to Certificate of Compliance 1 page Description and Tests Pages 1 to 8 Descriptive Documents (CSA file only) SUBMITTOR SpectraSensors Arrow Route Rancho Cucamonga, CA Location of Examination Same as submittor Location of Installation TBD PRODUCTS CLASS : PROCESS CONTROL EQUIPMENT For Hazardous Locations CLASS : PROCESS CONTROL EQUIPMENT For Hazardous Locations Class I; Division 1; Group C, D; T6 Model HCD4000 Hydrocarbon Dew Point Analyzer, Rated V, Hz, 150 VA, MWP: 1500 PSI. S/N CSA Label S/N CSA Label S/N CSA Label 5161 C C C C C C C Note: It is the responsibility of the user to install any necessary secondary seals on the conduit. The test report shall not be reproduced, except in full, without the approval of CSA International.

5 Page No: 2 APPLICABLE REQUIREMENTS C Canadian Electrical Code Part I. C22.2 No 0 M1991 General Requirements Canadian Electrical Code Part II. C22.2 No. 30 M1986 Explosion-Proof Enclosures for Use in Class I Hazardous Locations C22.2 No 142 M1987 Process Control Equipment. NFPA 70:2008 National Electrical Code UL 916 Ed 4 UL 1203:2006 Energy Management Equipment Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Locations MARKINGS Submittor s name, trademark Model designation. Complete electrical rating (Volts, Hertz, and VA). Serial number. Maximum Working Pressure (MAX 1500 PSIG). Hazardous Location designations. CAUTION: KEEP COVERS TIGHT WHILE CIRCUITS ARE ALIVE or the equivalent. INSTALL CONDUIT SEALS WITHIN 3 INCHES OF ENCLOSURE Note - Jurisdictions in Canada may require these markings to also be provided in French language. It is the responsibility of the manufacturer to provide bilingual marking, where applicable, in accordance with the requirements of the Provincial Regulatory Authorities. It is the responsibility of the manufacturer to determine this requirement and have bilingual wording added to the "Markings". METHOD OF MARKING: The markings appear on a laminated paper nameplate that is mounted behind the window of the enclosure. ALTERATIONS Markings as described above. FACTORY TESTS none

6 Page No: 3 DESCRIPTION The Model HCD4000 is an automated Hydrocarbon Dew Point Analyzer and consists of an assembly of certified components. The components are mounted within a culus listed Adalet enclosure XCE explosionproof enclosure for use in Class I, Div 1, Groups B, C and D. The enclosure is modified by Adalet to add four ¾ NPT threaded holes (two on each side of the enclosure) and three ½ NPT threaded holes on the bottom. The two holes on the right side of the enclosure are for power entry, the two holes on the left side of the enclosure are for signal entry. Two of the holes on the bottom of the enclosure are for gas entry and exit and the third hole is for a breather/drainer. The maximum enclosure dimensions are approximately 17 by 22 x 9-1/2. The threaded openings for the gas entry and exit are each fitted with a flame arrestor. The Model HCD4000 is rated for -10 to 40 C ambient temperature. Mounted interior to the enclosure are the following critical components: Ground Terminal Block Manufacturer: WAGO Model: Status: ccsaus Electrical Rating: N/A Neutral Terminal Block Manufacturer: WAGO Model: Status: ccsaus Electrical Rating: 600 V, 35 A, AWG wire Supply Terminal Block Manufacturer: WAGO Model: Status: ccsaus Electrical Rating: 600 V, 6.3 A, AWG wire Fused Terminal Block Manufacturer: WAGO Model: Status: ccsaus Electrical Rating: 600 V, 6.3 A, AWG wire Fuse Manufacturer: Littelfuse Model: F1AL Status: CSA, Electrical Rating: 2.5 A, 250 VP 5 Vdc Power Supply Manufacturer: Meanwell Model: MDR-60-5 Status: culus Electrical Rating: Input: Vac, Output 5 V, 10 A, 60 C

7 Page No: 4 5 Vdc Power Supply Manufacturer: Meanwell Model: MDR-20-5 Status: culus Electrical Rating: Input: Vac, Output 5 V, 3.0 A, 50 C 24 Vdc Power Supply Manufacturer: Meanwell Model: MDR Status: culus Electrical Rating: Input: Vac, Output 24 V, 0.42A, 60 C Wiring Manufacturer: SAB Cable Model: UL Style 1015, CSA Type TEW Status: CSA, Electrical Rating: 600 V, 105 C, VW-1, FT1 Digital Output Relay Manufacturer: Omron Model: G6E 134P-ST-US-DC5 Status: CSA, UL Electrical Rating: Coil Vdc; Contacts - 30 Vdc Digital Output Terminal Blocks Manufacturer: Phoenix Contact Model: PITTB 2,5 Status: CSA, Electrical Rating: 300 V/20 A The explosionproof Adalet enclosure is fitted with the following: Breather/Drain Manufacturer: HLS Model: Bd.1/2.S ½ NPT Status: ccsaus certified for Class I, Groups A, B, C, D Flame Arrestor Manufacturer: Adalet Model: XFAX2 Status: CSA, for Class I, Groups B, C, D The hydrocarbon gas measured by the HCD4000 may be at a pressure up to 1500 psi. The following components are used to contain the gas: Flame Arrestor Manufacturer: Adalet Model: XFAX2 Status: CSA, for Class I, Groups B, C, D Rating:

8 Page No: 5 NPT/Compression Fittings Manufacturer: Swagelok Model: SS Rating: 10,000 psi NPT/Compression Fittings Manufacturer: Swagelok Model: SS , SS Rating: 8,000 psi 1/8 Tubing Manufacturer: Swagelok Model: 1/8 Rating: 8,500 psi ¼ Tubing Manufacturer: Swagelok Model: ¼ Rating: 4,700 psi Gas Manifold Manufacturer: Ideal CNC Model: custom Rating: tested Gas Cell Manufacturer: Ideal CNC Model: custom Rating: tested Pressure Transducer Manufacturer: Ashcroft Model: G2 Rating: 0 to 2000 psig; proof pressure: 4000 psig; burst pressure: 10,000 psig DESCRIPTIVE DOCUMENTS Description Document Revision Enclosure Modification HCD4000 Labeling C HCD4000 Analyzer Assembly HCD4000 Outline/Wiring

9 Page No: 6 PHOTOGRAPHS Model HCD4000

10 Page No: 7 HCD4000 Internal View Representative Nameplate

11 Page No: 8 The product is an assembly of certified components. The following tests were performed on the assembly. Ratings: TEST REPORT Measured Voltage: Vac Vac Vac Vac Vac Measured Current: A A A A A Calculated VA: 109 VA 112 VA 114 VA 150 VA 162 VA The 150 VA on the nameplate is acceptable as the VA does not exceed the marked rating by more than 10% Temperature Rise: Temperature rise measurements were made with a representative unit operating at 240 Vac. The internal temperature rise below the power supplies was measured as 11 K, including a 5 K uncertainty. With a rated 40 C ambient temperature, the maximum temperature is calculated as 51 C. The MDR-60-5 and the MDR are rated to 60 C and no derating is required. The MDR-10-5 must be derated from 3 A to 2.9 A. The MDR-10-5 V power supply is used at a maximum of approximately 1 A. The top of the enclosure was measured as having a 11 K rise, including a 5 K uncertainty. This is consistent with a T6 temperature classification. Dielectric Test: Each unit was tested at 1500 Vac for one minute between supply and neutral conductors shorted together and the enclosure. The two power supplies were disconnected during this test. Explosive Seals test: The manifold and piping was tested at 4716 psi for 2 minutes. There was no leakage or rupture at this pressure. This is consistent with a 1500 psi rating. The Ashcroft Pressure Sensor and the flame arrestors were removed during this test based upon their published rating. No further testing was deemed necessary. End of Report

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Certificate: 2385571 Project 2447891 Issued to: Mine Safety Appliances 1000 Cranberry Woods Drive Cranberry Township, PA 16066 USA Issued by: Jocelyn Jens Product Group

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Certificate: 2708418 Issued to: Gems Sensors Inc. 1 Cowles Road Plainville, CT 06062 USA Attention: Mr. Philip I. Draper The products listed below are eligible to bear

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2325079 Issued to: Cooper Crouse Hinds GmbH Neuer Weg Nord 49 69412 Eberbach Germany Attention: Mr Günther The products listed below are eligible to bear the CSA

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2007104 Master Contract: 223077 Issued to: Purge Solutions 2201 North Highway 35 Bypass Suite C Alvin, TX 77511 USA Attention: Wallace Trochesset The products listed

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Certificate: 2792948 Issued to: Siemens Canada Limited 1954 Technology Drive Peterborough, ON K9J 7B1 Canada Attention: Mr. Lee Rogers The products listed below are eligible

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70033893 (166720) Issued to: WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Str 30 Klingenberg, 63911 GERMANY Attention: Uwe Schmidt The products listed below

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2185148 (217005) Issued to: RAE Systems, Inc. 3775 North First St San Jose, California 95134 USA Attention: James Pan The products listed below are eligible to bear

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Certificate: 70009779 Issued to: Pepperl+Fuchs GmbH Lilienthalstrasse 200 Mannheim, 68307 GERMANY Attention: Martin Holdefer The products listed below are eligible to bear

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1655492 (219995) Issued to: R.C. Systems Co., Inc. 8621 Hwy 6 Hitchcock, Texas 77563 USA Attention: Roger Carter The products listed below are eligible to bear the

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70000097 Project: 70125347 Issued to: Thermo Engineering S.r.l Via Giuseppina, 19 26030 Malagnino (CR) Italy Attention: Mr. BOZZETTI The products listed below are

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1238566 Issued to: Rosemount Analytical Inc. Solon Research & Development Ctr 6565-P Davis Industrial Pkwy Solon, OH 44139 USA Attention: Dana Crowley The products

More information

Certification Supplement Manual

Certification Supplement Manual PROCESS ANALYSERS SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 2 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EC DECLARATION OF CONFORMITY

More information

Certificate of Compliance

Certificate of Compliance FF02 Certificate of Compliance Certificate: 70068210 Issued to: Cascade Technologies Ltd Glendevon House, Castle Business Park, Stirling, Scotland. UNITED KINGDOM FK9 4TZ Attention: Mr M Douglas. The products

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Certificate: 70044220 Issued to: Cascade Technologies Limited Glendevon House Castle Business Park Stirling FK9 4TZ UK Attention: Mr. Marcus Douglas The products listed

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70067850 Date Issued: July 28, 2017 Issued to: Otis Instruments, Incorporated 301 S. Texas Ave. Bryan, Texas, 77803 USA Attention: Nicholas Sandera The products listed

More information

Certification Supplement Manual

Certification Supplement Manual PROCESS ANALYSERS SERVOTOUGH Oxy Gas Analyser Certification Supplement Manual Part Number: 01910008B Revision: 9 Language: UK English This page intentionally blank SERVOTOUGH Oxy Certification Supplement

More information

Centro-Matic Automated Lubrication Systems System Controls

Centro-Matic Automated Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

Certification Supplement Manual

Certification Supplement Manual SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 5 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EU DECLARATION OF CONFORMITY 3 EUROPEAN

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2595099 (LR 7189-177) Master Contract: 164196 Project: 2697346 Date Issued: January 28, 2014 Issued to: Tyco Electronics Corporation 2901 Fulling Mill Rd Mail Stop

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1055868 (LR 44092) Master Contract: 152450 Issued to: Micro Motion Incorporated 7070 Winchester Cir Boulder, CO 80301 USA Attention: Ray C. Stengl The products listed

More information

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS 3-VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination of flame proof and dust ignition proof assemblies, where,

More information

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS PENTAIR CLEAN AIR SYSTEMS 3-VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination of flame proof and dust ignition

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1469131 (LR 103134) Master Contract: 184981 Issued to: Industrial Monitoring Instr. (IMI) A Div. of PCB Piezotronics, Inc. 3425 Walden Ave Depew, NY 14043 USA Attention:

More information

ccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page

ccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page Title Page ccsaus certificate: EN 70001999 for EX Meggitt SA Route de Moncor 4 PO Box 1616 CH - 1701 Fribourg Switzerland ccsaus certificate 70001999 www.meggittsensingsystems.com www.vibro-meter.com THIS

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1563164 Issued to: Metal Samples Company, A Div. of Alabama Specialty Products, Inc. 152 Metal Samples Rd PO Box 8 Munford, Alabama 36268 USA Attention: Bala Palanisamy

More information

File E Project 97SC January 21, 1998 REPORT

File E Project 97SC January 21, 1998 REPORT File E135803 Project 97SC15289 January 21, 1998 REPORT ON COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT Condor DC Power Supplies Inc. Oxnord, CA

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2557738 Master Contract: 256526 Issued to: Bartec Varnost d.o.o Cesta 9 avgusta 59 Zagorje ob Savi, 1410 Slovenia Attention: Janez Gajski The products listed below

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2016-01-26 Page 1 of 7 Report Reference # E182560-V4-S52 UL TEST REPORT AND PROCEDURE Standard: ANSI/AAMI ES60601-1 (2005/(R)2012 + A1:2012, C1:2009/(R)2012 + A2:2010/(R)2012) - Amendment 1

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2613175 Master Contract: 162874 Project: 2613175 Date Issued: April 18, 2013 Issued to: Fujitsu Technology Solutions GmbH Product Compliance Center Buergermeister-Ulrich-Str

More information

for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN

for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN Title page CCSAUS certificate: EN 70034691 for EX Meggitt SA Route de Moncor 4 PO Box 1616 CH - 1701 Fribourg Switzerland CCSAUS certificate 70034691 www.meggittsensingsystems.com www.vibro-meter.com THIS

More information

Explosion Proof Line Powered Telephone Ringer

Explosion Proof Line Powered Telephone Ringer Explosion Proof Line Powered Telephone Ringer P7020 CE20 Without Projection Horn P7021 CE20 With Projection Horn P004572 Rev. E 180416 4/16/2018 12:32 PM Ph: 403.258.3100 \ email:info@guardiantelecom.com

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Issued to: Exheat Ltd. Threxton Road Industrial Estate Watton Thetford Norfolk, IP25 6NG UNITED KINGDOM Attention: James Pettman The products listed below are eligible

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70000287 (085005_0_000) Issued to: steute Schaltgeräte GmbH & Co. KG Brueckenstrasse 91 Loehne, 32584 GERMANY Attention: Patrick Keilwerth The products listed below

More information

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. WARNING FOR YOUR SAFETY:

More information

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance Page 1 of 165 Report No.: E309264-D1028-1/A0/C0-UL Test Report issued under the responsibility of: IEC 60601-1 Medical electrical equipment Part 1: General requirements for basic safety and essential performance

More information

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates Note: While this material was originally prepared for presentation in February 1999, it has been updated to reflect the evolving technical requirements now applicable as of April 2003. UL Topic III Converting

More information

UL Electrical Equipment for Measurement, Control, and Laboratory Use; Part 1: General Requirements, Second Edition

UL Electrical Equipment for Measurement, Control, and Laboratory Use; Part 1: General Requirements, Second Edition File E315190 Project 07CA39477 March 5, 2008 REPORT on PROCESS CONTROL EQUIPMENT FOR USE IN HAZARDOUS LOCATIONS Litre Meter Ltd. Buckinghamshire, England Copyright 2008 Underwriters Laboratories Inc. Underwriters

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2011-01-24 Page 1 of 18 Report Reference # E183863-A17-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment

More information

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas UL 1203 CSA C22.2 NO. 30-M1986 The D1xS1 and D1xS2 Alarm Horns also comply with the following standards for signaling

More information

standards: standards:

standards: standards: INSTRUCTION MANUAL D2xB1LD2 LED Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING HAZARD

More information

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System 1. GENERAL 1.1 INTENT OF SPECIFICATIONS A. This specification details the requirements for an engineered inert gas fire suppression system Model Kidde Nitrogen. These requirements, combined with good engineering

More information

ELECTRICAL SAFETY Information Bulletin

ELECTRICAL SAFETY Information Bulletin ELECTRICAL SAFETY Information Bulletin June 2018 CEC-18 [rev-13] Page 1 of 6 CANADIAN ELECTRICAL CODE SUBJECT: Section 18 Hazardous locations Rule 18-006 Locations containing an explosive gas atmosphere

More information

Technical Specification VFD

Technical Specification VFD Technical Specification - 3-6 VFD Pilot valve enclosures suitable for use in hazardous certified environments. These enclosures are designed and tested to contain both flame and the ignition of dust and

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D1xC COMBINED RADIAL HORNS & STROBES For Use In Hazardous Locations - Gas 3) Ratings and Markings The D1xC1 and D1xC2 combined alarm horns and strobes comply with the following

More information

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance

More information

FX5 Series Explosion-Proof Electric Air Heaters

FX5 Series Explosion-Proof Electric Air Heaters FX5 Series Explosion-Proof Electric Air Heaters Ruffneck FX5 heaters are C UL US certified for use in hazardous locations. They are designed for the harshest environments such as: dry indoor industrial

More information

Power Supply Display Module PSDM. Installation and Operation Manual

Power Supply Display Module PSDM. Installation and Operation Manual Power Supply Display Module PSDM Installation and Operation Manual Read this manual before using this product. Failure to follow the instructions and safety precautions in this manual can result in serious

More information

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74 AM54 Instruction Bulletin North American Installation Addendum Document Number PN25016 Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

More information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information INSTRUCTION MANUAL D1xB2XH1 Xenon Beacon For use in Hazardous Locations 2) Rating & Marking Information 2.1 Public Mode Fire Alarm Ratings The D1xB2XH1 is certified for use as public mode visual alarm

More information

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information INSTRUCTION MANUAL D1xB2XH2 Xenon Beacon For use in Hazardous Locations 2) Rating & Marking Information 2.1 Public Mode Fire Alarm Ratings The D1xB2XH2 is certified for use as public mode visual alarm

More information

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series) Stars Management JLT SUBMITTAL EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series) Tel: 00971 (04) 457 2383 Fax: 00971 (04) 457 2382 P.O. Box: 25867 Dubai U.A.E. E-mail: info@starsmanagementjlt.com Website:

More information

Descriptive Report and Test Results

Descriptive Report and Test Results Descriptive Report and Test Results MASTER CONTRACT: 211066 Edition 1: Edition 2: November 4, 2013; Project 2661531 Montréal Issued by Viorel Popovici Eng., Review by: Gabriel Raymond B. En. January 20,

More information

File E Project 05ME Issued: November 1, 2005 Revised: February 27, 2009 REPORT

File E Project 05ME Issued: November 1, 2005 Revised: February 27, 2009 REPORT File E133400 Project 05ME09466 Issued: November 1, 2005 Revised: February, 2009 REPORT On COMPONENT POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT TDK-Lambda Americas

More information

Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request)

Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request) Type Y & Z purge and pressurization system Features Assembly NFPA 70, NFPA 496, ISA 12.4 standards Optional alarm output indicates air lock failure Type Y system certified for Class I and Class II, Division

More information

Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request)

Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request) Type Y & Z purge and pressurization system 1004 Features Assembly NFPA 70, NFPA 496, ISA 12.4 standards Optional alarm output indicates air lock failure Type Y system certified for Class I, Division 1

More information

Installation Requirements for Models:

Installation Requirements for Models: 900 & 9100 Series Refrigerators Installation Requirements for Models: 9162 9163 9182 9183 962 963 982 983 WARNING Improper installation, adjustment, alteration, service, or maintenance can cause injury

More information

PILOT VALVE ENCLOSURES

PILOT VALVE ENCLOSURES PILOT VALVE ENCLOSURES PENTAIR ENVIRONMENTAL SYSTEMS 3-VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination of flame

More information

ELECTRICAL SAFETY Information Bulletin

ELECTRICAL SAFETY Information Bulletin ELECTRICAL SAFETY Information Bulletin October 2007 Page 1 of 11 CANADIAN ELECTRICAL CODE SUBJECT: Section 18 Hazardous Locations Rule 18-006 Division of Class I Locations General For classification requirements

More information

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153 INDEX GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 Model(s) Page(s) Flush Mount Fan/Limit/Attic Fan Control... 152 GAS DRYER VALVES 153 Model(s)

More information

Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request)

Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request) Type Y, Z & Ex [pz] purge and pressurization system 3003 Features Assembly NFPA 496, ISA 12.4, and ATEX standards Optional alarm output indicates air lock failure Optional differential pressure switch

More information

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc MASTER JOCKEY PUMP CONTROLLER Model JPCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page 4 Model

More information

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2 I&M NUMBER: 316-42-15-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

Introduction to Flow Switch

Introduction to Flow Switch Introduction to TM Solutions Flow Detection, Switching & Control Flow switches detect a change in state from flow or no-flow within pipe or ducting. Correspondingly, the sensor inverts a contact to signal

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS I. GENERAL Heatrex Explosion-proof Pipe Thread Mounted Immersion Heaters are CSA approved

More information

NEC Requirement Guidelines 2002 Code Options for the Installation of Listed Less-Flammable Liquid-Filled Transformers

NEC Requirement Guidelines 2002 Code Options for the Installation of Listed Less-Flammable Liquid-Filled Transformers NEC Requirement Guidelines 2002 Code Options for the Installation of Listed Less-Flammable Liquid-Filled Transformers BULLETIN 92046 APPLICATION INFORMATION NOVEMBER 2002 SUPERSEDES August 2002 CONTENTS

More information

Owner s Manual. FX4 Series. Electric Forced Air Heaters for Hazardous Locations

Owner s Manual. FX4 Series. Electric Forced Air Heaters for Hazardous Locations Owner s Manual FX4 Series ISO 9001 Electric Forced Air Heaters for Hazardous Locations This manual covers the installation, maintenance, repair and replacement parts. approved Locations The Electric Forced

More information

Honeywell Durafit LED Retrofit Kit

Honeywell Durafit LED Retrofit Kit Honeywell Durafit LED Retrofit Kit INSTALLATION INSTRUCTIONS LED RETROFIT LUMINAIRE CONVERSION FOR USE ONLY WITH PRODUCTS DESCRIBED AND INSTALLED IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS

More information

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001 SLATE Burner Control Module R8001B2001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform

More information

Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations. Description. Installation WARNING

Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations. Description. Installation WARNING Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations STANCHION 116EX-S CEILING 116EX-C 3/ CONDUIT ENTRIES PENDANT 116EX-P 3/ CONDUIT ENTRY 116EX-C (WALL

More information

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc MASTER PRESSRE MAINTANENCE CONTROLLER Models PMCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page

More information

Installation, Operation, & Maintenance Manual. MODEL: MPRVSS (NGL Sr.), MPRVSSJR (NGL Jr.)

Installation, Operation, & Maintenance Manual. MODEL: MPRVSS (NGL Sr.), MPRVSSJR (NGL Jr.) U.S. Patent No. 9.285.299 Installation, Operation, & Maintenance Manual Mustang Pressure Regulating Vaporizer Sampling System MODEL: MPRVSS (NGL Sr.), MPRVSSJR (NGL Jr.) P (304) 273-5357 F (304) 273-2531

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following

More information

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES PART 1 GENERAL A. The requirements of the Contract, Division 1, and Division 16 apply to work in this Section. 1.01 SECTION INCLUDES A. Lighting and appliance panelboards 1.02 RELATED SECTIONS A. 16475,

More information

Installation Instructions

Installation Instructions WARNING! INSTALLATION SAFETY INSTRUCTIONS Read these instructions completely and carefully. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer

More information

Genie Heated Regulator Installation & Operation Instructions

Genie Heated Regulator Installation & Operation Instructions Genie Heated Regulator Installation & Operation Instructions Manufacturing Contact Information A+ Corporation, LLC Call for expert product application assistance: 41041 Black Bayou Rd. Gonzales, LA 70737

More information

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations INSTRUCTION MANUAL D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations synchronization requirements of UL1971 & UL1638 / CAN/ULCS526. 2.2 NEC & CEC Class / Division Ratings for US / Canada

More information

POWER AND CONTROL PRODUCTS QUICK RESPONSE PROGRAM.

POWER AND CONTROL PRODUCTS QUICK RESPONSE PROGRAM. POWER AND CONTROL PRODUCTS QUICK RESPONSE PROGRAM. CUSTOM CONFIGURED PRODUCTS READY FOR SHIPMENT IN ONE TO TEN BUSINESS DAYS. Appleton s Quick Response Program places select power and control products

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2016-01-22 Page 1 of 9 Report Reference # E182560-V4-S48 UL TEST REPORT AND PROCEDURE Standard: ANSI/AAMI ES60601-1 (2005/(R)2012 + A1:2012, C1:2009/(R)2012 + A2:2010/(R)2012) - Amendment 1

More information

WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations.

WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations. Cheshire, CT 064 3-699-30 (Ph) 3-699-3365 (Cust. Serv. Fax) 3-699-78 (Tech. Serv. Fax) Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations STANCHION

More information

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion

More information

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) T M 1 isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012372 / 03.2015 isopv

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2010-12-01 Page 1 of 16 Report Reference # E252373-A31-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2014-10-14 (Information

More information

Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request)

Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request) Type Y, Z & Ex [pz] purge and pressurization system 3004 Features Assembly NFPA 496, ISA 12.4, and ATEX standards Optional alarm output indicates air lock failure Optional differential pressure switch

More information

Installation Instructions

Installation Instructions 50ES--A, 50EZ--A, 50VG--A, B, 50VL--A, B, 50VR--A, 50VT--A, B 604D-- --A, 607C-- --A, B, 607E-- --A, 704D-- --A, 707C-- --A, B, 707E-- --A PA3G -- -- A, PH3G -- -- A, PA4G, PH4G PAD3, PHD3, PAD4, PHD4,

More information

Installation Instructions. Distinctive Electric Cooktop. Françis : voir page 11 Español: consulte la página Rev. A. Models DECT304, DECT365

Installation Instructions. Distinctive Electric Cooktop. Françis : voir page 11 Español: consulte la página Rev. A. Models DECT304, DECT365 Distinctive Electric Cooktop Models DECT304, DECT365 Installation Instructions 105643 Rev. A Françis : voir page 11 Español: consulte la página 21 Table of Contents Page Special Warnings... Product Dimensions

More information

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \ Ring Detect Relays Installation & Operation P005116 Rev. D 141020 10/20/2014 11:25 AM Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com Table of Contents Package Contents...2

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS T CLASS TSA Series 6 to 20 Ton AIR CONDITIONERS 6 20 TONS 506147 01 06/11 Supersedes 3/11 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT The Clean Air Act

More information

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS APPLICATION INDEECO Explosion proof Electric Immersion Heaters for Hazardous Locations are ccsaus Certified for use in areas (external

More information

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations INSTRUCTION MANUAL E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING

More information

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY Bousquet Technologies Inc. 2121, Nobel, Ste Julie, Quebec, Canada, J3E1Z9 SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL Oil-Fired air heater for industrial and commercial use. FOR YOUR SAFETY Do not

More information

Ultrasonic Point Level Switches

Ultrasonic Point Level Switches see more at SORInc.com Request Quote Ultrasonic Point Level Switches Ultrasonic point level switches are a cost-effective solution for your applications. Installation requires mounting the sensor (threaded

More information

ELECTRICAL SAFETY Information Bulletin

ELECTRICAL SAFETY Information Bulletin ELECTRICAL SAFETY Information Bulletin February 2014 CEC-18 [rev-11] Page 1 of 9 CANADIAN ELECTRICAL CODE SUBJECT: Section 18 Hazardous Locations Rule 18-006 Division of Class I Locations General For classification

More information

Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations

Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations CEILING 116EX-C 3/ CONDUIT ENTRIES PENDANT 116EX-P 3/ CONDUIT ENTRY 116EX-C (WALL MOUNTED)

More information

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM 1. GENERAL SPECIFICATION 1.1. A total flooding, FM-200 fire suppression system, super-pressurized with dry nitrogen shall be installed to meet a minimum design concentration of %, by volume in all designated

More information

Installation Instructions for W2H Series Signals

Installation Instructions for W2H Series Signals Installation Instructions for W2H Series Signals IF1513 A Description and Operation DIMENSIONS W2H A 8 7/8" (225 mm) B 8 1/4" (210 mm) C 13" (330 mm) Figure 1. Speaker/Amplifier Dimensions The W2H signaling

More information

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \ Ring Detect Relays Installation & Operation P005116 Rev. E 180803 8/3/2018 11:19 AM Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com Table of Contents Package Contents... 2 Models

More information

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Brooks MT3600 Series Metal Tube Variable Area Flowmeters Data Sheet Flanged, NPT or socket-welded connections 10% full scale accuracy Disassembly for cleaning without removal from the process line Standard direct reading, detachable scales Permanent magnetic

More information

Q7800H Integrated Burner Control Subpanel

Q7800H Integrated Burner Control Subpanel Q7800H Integrated Burner Control Subpanel INSTALLATION INSTRUCTIONS FEATURES Unique subpanel design eliminates extensive wiring in the OEM control panel. One subpanel design covers multiple applications.

More information