Installation Manual GalaXy G2 / G3 / GD. o Settings GalaXy o Linking with iprotect o Keymap

Size: px
Start display at page:

Download "Installation Manual GalaXy G2 / G3 / GD. o Settings GalaXy o Linking with iprotect o Keymap"

Transcription

1 Installation Manual GalaXy G2 / G3 / GD o Settings GalaXy o Linking with iprotect o Keymap

2 Publication July 2013, Keyprocessor BV Paasheuvelweg BJ Amsterdam, The Netherlands Tel.: This manual reflects the knowledge at the above mentioned time. Keyprocessor works nonstop to improve her products. For the most recent technical information please contact your consultant or dealer. Content overview Publication... 2 Content overview Introduction Sticker i-serie Required version Settings GalaXy If internal RS232 module If external RS232 module Neutralize alarm limitation Settings iprotect Add line Add node Add alarm point Add alarm group Add alarm output Alarm user Group and admittance Card reader Visualization alarm system in keymap Placing Widgets Alarm point status Physical status Logical status Calculated status General Type statuses Numbers Keymap (Floor plan) Event... 18

3 1 Introduction 1.1 Sticker i-serie This manual describes the linking between iprotect and the GalaXy intrusion system. This document is based on iprotect version It is possible that some features cannot be used in older versions of iprotect. 1.2 Required version Attention: deviations from the specified versions, no guarantee can be given concerning the operation of the link. GalaXy G2 G3 Dimension Type Firmware version Combinable with iprotect version From 6.01 From 7.02 From 7.02 External RS232 Necessary module Version Possible, but not necessary NO, internal RS232 module NO, internal RS232 port

4 2 Settings GalaXy 2.1 If internal RS232 module Connect the internal RS232 connection directly to a ipu-8 (PRT2) or Polyx (PRT4). Connection plan: RJ45 Wire color (T568B) RS232 Port G3 RS232 ipu-8 / Polyx 1 White/orange RTS 1 2 Orange CTS 2 3 White/green Blue RX 4 5 White/blue TX 5 6 Green White/brown Brown GND 8

5 Maximal cable length: 15m. Pin order: RJ45 plug RJ45 socket In the GalaXy center you can program at menu option 56 Communication the internal RS232 modul. Choose at menu 56 option 6 (Internal RS232 1). You get a choice out of the next options: Menu structure Internal RS232 Module 01=MODE 1=PRINTER 1=DIRECT 2=MODEM 02=FORMAT 1=SIA CHOOSE SIA NIVO 0(0-4) 2=Microtech 1=SIA MESSAGES 03=CUSTOMER 4 to 6 digits NO 04= COMM SET-UP 1=Baud Rate 2=Data Bits 3=Stop Bits 4=Parity 1=TELEFON NUMBER. 2=Choose type 1=Show 2=Pulse 3=Initialisation string 1=SIA MESSAGES 1=STATUS 2=BLOCKS 1=No parity 2=Uneven parity 3=Even parity 1=STATUS 2=BLOCKS Select option 1: Mode=Direct (press then on <ESC>) Select option 2: Format=SIA (Set here the desired events which have to be received by iprotect ) Select option 3: enter the customer number (4 to 6 digits) Note: If no customer number is entered, no SIA messages will be displayed within iprotect! Choose SIA Level= 4 (*) Baud Rate = Data Bits = 8 Stop Bits = 1 Parity = None

6 (*) Level 0 (default): Basic event information with 4 digit customer number Level 1 : Equal to Level 0, but with 6 digit customer number Level 2 : Equal to Level 1, but with extra event information Level 3 : Equal to Level 2, but with textual description (highest available level for alarm room) Level 4 : Equal to Level 3, but with addition of commands which can be received by the GalaXy. This level cannot be used for the Dutch alarm rooms. After selection of the SIA level, the first trigger will be displayed with the corresponding status (see table underneath). The most messages which can be sent to a receiver by a GalaXy centre are subdivided at the triggers. Use the [A]- or [B]-button or press directly the number for selecting the desired trigger. Press then on the [ent]-button for adapting the settings of this trigger. Nr. Trigger Nr. Trigger 1 Panic 11 Reset 2 Burglary 12 Modules/Comms 3 24-hours VAC errors 4 Security 14 Menu Access 5 Custom Zones 15 Malfunction 6 Fire 16 Memory Zone 7 Error switching on 17 MAX memory 8 Bypassed 18 Zone repair 9 Sabotage 19 RF Supervision 10 Switching on 20 Error Do not the installer menu yet. 2.2 If external RS232 module Install the GalaXy centre according to the manual. For installer codes etc. see also the corresponding manual. Unlink temporarily any possible modem/choosers (if version 1.03 or higher). Connects the ipu-8/polyx of the iprotect system with the RS232 connector JP2 of the RS232 module of the GalaXy centre. See cable plan on next page.

7 Position of connection JP2 on the RS232 module of the GalaXy centre Cable plan JP2 RS232 module 25p SubD Female Pin 2 TXD Pin 3 RXD Pin 7 GND ipu-8/polyx RJ45 Pin 5 - RXD Pin 4 - TXD Pin 7/8 - GND Switch on the net voltage of GalaXy centre. Check at DIP of the RS232 module the correct settings: Switch 1: Off Switch 2: Off Switch 3: Off Switch 4: Off Switch 5: Off

8 Switch 6: On Switch 7: Off Switch 8: On Check the LED s of the RS232 module. LED2 (red) must burn continuously. LED1 (red) states the communication quality. ON (SEC) OFF (SEC) STATUS Good communication Bad communication No communication not configured/recognized In the GalaXy centre you can program at menu option 56 Communication the external RS232 module. Choose at menu 56 option 2 (External RS232 module). You get the choice from these options: 01=MODE Menu structure External RS232 Module 2=MODEM 3=X25 PROT 02=FORMAT 1=SIA CHOOSE SIA NIVO 0(0-3) 2=Microtech 1=SIA MESSAGES 03=CUSTOMER NO 04=COPYOVERWRIT 1=Received Data 05=COMM SET-UP 2=Sent Data 1=DIRECT 1=TELEPHONE NOS 2=Choose type 1=Show 2=Pulse 1=SIA MESSAGES 4 to 6 digits 1=Start 2=Stop 1=Start 2=Stop 3=Data Stored 1=STATUS 2=BLOCKS 1=STATUS 2=BLOCKS Select option 1: Mode=Direct (Press then on <ESC>) Select option 2: Format=SIA (Set here the desired events which must be received each by iprotect) Choose SIA Level= 3 Press then a number of times on <ESC> and leave the Master menu. <Again Master code + <ESC> Select option 3: enter the customer number (4 to 6 digits) Note! If no customer number is entered, no SIA messages will be displayed within iprotect!

9 2.3 Neutralize alarm limitation (This is valid for internal and external RS232 module.) Choose at menu 51 option 48. Set the following three options on 0 : Number of alarms Switch off limit Switch on limit Note! If you do not execute this setting, it can happen that not all alarms will be displayed. Exit the installer menu.

10 3 Settings iprotect 3.1 Add line For being able to make the correct settings for communication between iprotect and a Galaxy alarm centre, the configuration of the Galaxy centre, which is set by the installer, must exactly be taken over in iprotect. Click in iprotect on the menu item Installation Hardware Line. Right-click in the browse window and select Add line. The detail window opens. Enter the following data: Name: Specify a logical name Type: Network device Active: (check) Mode: Keyprocessor/Profibus IP-address: the IP-address of the ipu-8/polyx Encrypted: (check) Compressed: (check) Tolerance: 0 Communication frequency: direct Line sort: local Sun or Ethernet Save the data. 3.2 Add node Click in iprotect on the menu item Installation Hardware Node. Right-click in the browse window and select Add node. The detail window opens. Enter the following data: Name: Specify a logical name Type: Select at Type : Galaxy. Subnumber: 3 or higher Subtype: Select the corresponding subtype : GD (520) or G3 (520) or G2 (512). Password: Enter the password < the Remote Service Code of the Galaxy centre, by default > Baudrate: Set to Address serial port: - ipu-8: scc02: - Polyx: tty02: Check Active. Save the data. Add alarm

11 3.2.1 Add alarm point Click in iprotect on the menu item Installation Hardware Alarm system Third Party Alarm point. Right-click in the browse window and select Add alarm point. The detail window opens. Enter the following data: Name: Specify a logical name (Copy of the name of the GalaXy alarm point) Node: Select the node to which this alarm point belongs Bypassed: No Enter the number of the alarm point Dipswitch 8 (RIO-0): Check if RIO 0 is used (onboard). The alarm point numbers are: iprotect: Alarm point number GalaXy: Alarm point number SIA: Alarm point number Save the data. Note! The name of the alarm point needs to be unique in iprotect. Keep in mind when linking multiple GalaXy intrusion systems to iprotect Add alarm group Click in iprotect on the menu item Installation Hardware Alarm system Third Party Alarm group. Right-click in the browse window and select Add alarm group. The detail window opens. Enter the following data: Name: Specify a logical name (Copy of the name of the GalaXy alarm group) Node: Select the node to which this group belongs Area: Select an access area. This setting is needed when arming and disarming the (secured)area, using a card reader. Number: Enter the desired group number.<block A1=1, A2=2,.. B1=9 Modus: Select switched off at mode. Point changes when group off: Select a time zone (example: Office) < In other words, during which time zone must iprotect monitor the alarm points for e.g. displaying these statuses on the Keymap> Write point events to database: Select a time zone (example: Office) < In other words, during which time zone must iprotect register the alarm points for e.g. logging these statuses as event and triggering procedures> Save the record. Right-click in the treeview on the Alarm group. Add alarm point. < Select the earlier created alarm points at the correct alarm group. Corresponding with the programming in the Galaxy centre > Note! Using a GalaXy G3 or GD, one alarm point can be linked under multiple alarm groups. Using a GalaXy G2, one alarm point can be linked under one alarm group.

12 3.2.3 Add alarm output Click in iprotect on the menu item Installation Hardware Alarm system Third Party Alarm output. Right-click in the browse window and select Add alarm output. The detail window opens. Enter the following data: Name: Specify a logical name (Copy of the name of the GalaXy alarm output) Node: Select the node to which this alarm output belongs Mode: Off Output number: Enter the number of the alarm output Test the link. Note! It is possible to control via iprotect outputs of the Galaxy centre. In account has to be taken then that this is not operating in contradiction to the function as given with the Galaxy centre Alarm user Group and admittance The alarm user Group determines whether the user may arm or disarm the security area. Open in iprotect the menu item Installation Hardware Alarm system Third party Alarm user group. The detail window opens. Enter the following data: Name: Specify a logical name Arm: check if allowed to arm the security area Disarm: check if allowed to disarm the security area Save the record. Click in the browse window and click the plus sign of the alarm user group and select 'Area list'. Check the desired areas and save. Open in iprotect the menu Access Settings Admittance to add the Alarm user group to an existing Admittance Save the record Card reader Open in iprotect the menu item Installation Hardware Reader. Select a card reader which will be used to arm or disarm the security area. The detail window opens. Open the Tab Security Area: Show security area status on LED: Select a desired security area < The LED from the card reader will blink when security area is Armed> Arm security area: Select a desired security area Disarm security area: Select a desired security area Open the Tab APB: Select the undefined access area Outside for access control at From area. Select the access area you enter at To area. Save the record.

13 4 Visualization alarm system in keymap 4.1 Placing Widgets Create under General Settings Keymap a floor map. Click in the frame of the detail window and load a picture of the building or from a floor where detectors are installed. Save the record. The image will now be displayed as a background image for the alarm visualization. Loading the background image for the floor map (Dutch working station) In the treeview underneath the new record of the floor map the record Widget positioning has appeared. Click on this record. The detail window Widget positioning opens. By means of Widgets you can now display each sort status of each / each alarm point. Repeat for each Widget the next steps: 1. Right-click on the background image and choose Security message (third party). Choose alarm point and then the sort status, which you want to have displayed. See for this the next chapter about alarm point statuses. 2. The default symbol for the momentary status of a default alarm point appears. Drag with the mouse the Widget on the desired place and set the size of the Widget. 3. Click on the tab sheet Widget control. Select at column value the alarm point, of which the status has to be shown. You can adapt at column name the status once more (you see here a bigger number statuses and parameters from which you can choose). On top of this on the tab sheets you can set or determine the size and

14 position of the Widget exactly, that the status is not displayed with a symbol, but textual. Placing Widgets on the background image. In this example three statuses are stated by a symbol (e.g. ) and on the right - textual (e.g. sabotage closed ). You can set comparable statuses of alarm groups. Which default symbols represents which value of a alarm point or alarm group status, can you view at General Settings Keymap Icon assignment. Open at General Overviews the new floor map. Check whether changes at the detectors are shown in the right way. 4.2 Alarm point status You can have 3 sorts status of an alarm point (detector) shown: Physical status (or point status in the detail window of the alarm point) Logical status and Calculating status (or alarm status in the detail window of the alarm point) Physical status The physical status states which resistance the system measures in the detector circuit: Resistance Normal (operative low) E.g. Default icon color Physical status message in iprotect Description 0Ω or Sabotage closed Sabotage to detector endless 4.700Ω Loop closed Detector changes resistance regular detector operation

15 Open (operative high) 9.400Ω Loop opened Detector changes resistance regular detector operation unknown Example values are valid for a DEOL 4k7k The physical status can be separated thus into 3 groups: Extreme resistance values which can only be explained by sabotage of the detector ( Sabotage closed / Sabotage opened ), this alarm situation will be notified with the highest priority independent of e.g. the detector operation Unusual resistance values which cannot be explained by normal detector operation and e.g. can hint on cable contact ( Low resistance / High resistance ) Resistance values, which the detector can assume at regular function ( Normal / Open ) Logical status The logical status is a first interpretation of the resistance value based on the sort detector and entered parameters (e.g. bypassed on yes ): Idle: the detector does not notice an insecure situation Active: the detector notices an insecure situation, but his alarm group does not stand on armed Alarm: the detector notices an insecure situation and his alarm group stands on armed Bypassed: the messages of this detector will be ignored by the system Sabotage: e.g. someone opens the housing of the detector without permission Local alarm Hold-up alarm Unknown Calculated status The calculated status is a combination of the logical status of the detector and the en de arming of the alarm group of the alarm point: Idle: the alarm group of the alarm point is not standing anymore on armed and the alarm point does not send an alarm message Activated: the alarm group of the alarm point stands on armed and the alarm point sends no alarm message Active: the alarm group of the alarm point does not stand on armed, the alarm point has passed an alarm message and the alarm group has not been reset Alarm: the alarm group of the alarm point stands on armed, the alarm point has passed an alarm message and the alarm group has not been reset Bypassed: the alarm group of the alarm point stands on bypassed

16 Overview: Calculated status Alarm group armed? Message of alarm point? REST NO NO SWITCHED ON YES NO ACTIVE NO YES ALARM YES YES BYPASSED BYPASSED/NO NO BYPASSED/ SWITCHED ON BYPASSED/YES NO BYPASSED/ACTIVE BYPASSED/NO YES BYPASSED/ALARM BYPASSED/YES YES

17 5 General 5.1 Type statuses Physical status (the real loop status) Open (resistance value) Closed (resistance value) Logical status (the translation of the physical status to an alarm situation) Switched on, in alarm, tamper, etc Calced status The translation of [physical + logical] in combination with the (alarm-) status of the group in which the zone sits. At switching off the block the point which has been in alarm, will automatically be reset. 5.2 Numbers Table Numbers to be defined Alarmgroup 256 Alarmpoint 2500 Alarmgroupalarmpoint 2500 AlarmExternal Keymap (Floor plan) Keymap Widgets Alarm External (MODE) 0) Off; 1) On Alarm External (STATUS) 0) Off; 1) On Alarm Group (STATUS) 0) Switched off; 1) switched on; 2) Partly switched on Alarm Group (MODE) 0) Switch off; 1) switch on; 2) switch partly on Alarm Group (ALARM) 0) Normal; 1) Alarm Alarm point (CALCEDSTATUS) 0) Rest; 1)Switched on; 2)Active; 3)Alarm; 4) Bypassed; 5) Bypassed/switched on; 6) Bypassed/Active; 7) Alarm/Bypassed Alarm point (LOGICALSTATUS) 1) Sabotage; 2) Alarm; 3) Normal 4) holdup alarm; 5) Local alarm; 7) bypassed; 10) Active Alarm point (MODE) 0) No; 1) Yes Alarm point (PHYSICALSTATUS) 1) Sabotage closed; 3) Loop closed; 5) Loop opened (alarm); 6) Sabotage opened

18 5.4 Event Go to the menu: General Settings Event. Click in the search window on Search. Within iprotect the next event types can be used: Alarm point: Status changed Alarm point: Bypass status changed Alarm point: Mode changed Alarm output: Status changed Alarm output: Mode changed Alarm group: Status changed Alarm group: Mode changed Alarm group: Alarm changed

User manual. KNXgal. version

User manual. KNXgal. version User manual version 1.3 gal Management alarm control panels Galaxy from bus powered from bus Communication indication on and with Galaxy control panel DIN rail mount (1 modul) Adjustable address on with

More information

User manual. KNXpar. version

User manual. KNXpar. version User manual version 1.3 KNXpar Management alarm control panels Paradox from KNX bus Powered from KNX bus Communication indication on KNX and with Paradox control panel DIN rail mount (1 module) Adjustable

More information

FST DFS Notifier Onyx 640

FST DFS Notifier Onyx 640 1 DESCRIPTION The NFS-640 Serial driver allows the FieldServer to record data from Notifier Onyx Series NFS-640, NFS2-640 and NFS-320 Fire Panels over RS-232. The FieldServer primarily acts as a Passive

More information

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system. Page : 1 of 17. ELAUSYS JA-KNX KNX Interface for Jablotron alarm system User Manual Document history Version. Date Author Comment 1.00 24-JUN-2017 NDE First issue 1.01 14-NOV-2017 NDE Support for user

More information

Running IGSS as an Operator, Part One

Running IGSS as an Operator, Part One Running IGSS as an Operator, Part One Contents Duration We want to see how a completed IGSS SCADA system appears to plant operator personnel to get an idea of the various elements in the system and how

More information

HRX Technical Manual. Version 1.2

HRX Technical Manual. Version 1.2 HRX 5000 Technical Manual Version 1.2 Contents: Specification...2 Connectors...5 RS-485 Network Connectors (J6 and J7)...5 RS-232 to Printer (J19)...6 RS-232 to PC (J8)...7 TCP/IP...8 Power (J21)...9 Fire

More information

SETTING UP A VIRTUAL KEYPAD WITH A DSC POWERSERIES ALARM SYSTEM

SETTING UP A VIRTUAL KEYPAD WITH A DSC POWERSERIES ALARM SYSTEM DN1902-0909 SETTING UP A VIRTUAL KEYPAD WITH A DSC POWERSERIES ALARM SYSTEM The purpose of this application note is to configure the EntraPass system to interface with the DSC PowerSeries tm alarm systems

More information

Simplex Panel Interface Guide

Simplex Panel Interface Guide Simplex Panel Interface Guide February 2016 SATEON Software Integrations Simplex Panel Interface Guide Issue 1.0, released February 2016 Disclaimer Copyright 2016, Grosvenor Technology. All rights reserved.

More information

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems Honeywell Life Safety Iberia C/Pau Vila 15-19; 08911 Badalona Barcelona T. 902 03 05 45; Internacional:+34932424236 www.honeywelllifesafety.es infohlsiberia@honeywell.com ibox Modbus Server Gateway for

More information

Monitoring Operator Guide. Access Control Manager Software Version

Monitoring Operator Guide. Access Control Manager Software Version Monitoring Operator Guide Access Control Manager Software Version 5.10.10 2018, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACCESS CONTROL MANAGER, ACM, ACM VERIFY AND TRUSTED

More information

FieldServer Driver - Serial FS Notifier NCA

FieldServer Driver - Serial FS Notifier NCA Driver Version: 1.00 Document Revision: 15 Description FieldServer Driver - Serial FS-8700-98 Notifier NCA The NCA (Network Control Annunciator) Serial driver allows the FieldServer to record data from

More information

FCD-wire Contents. List of Figures

FCD-wire Contents. List of Figures FCD-wire Contents FCD-X21 Configuration 1 Introduction... 1 2 Opening the FCD Application... 1 3 FCD Window... 2 4 FCD LEDs... 3 5 Configuration Operations... 4 FCD Info...4 FCD System Info...5 FCD Interface

More information

HRX3000. Technical Manual

HRX3000. Technical Manual HRX3000 Technical Manual Contents: Specification...2 Connectors...3 Power (J21)...3 RS-485 Network Connectors (J6 and J7)...4 RS-232 to PC (J8)...5 Printer and Fire Alarm Panel (J19)...6 TCP/IP...8 Modem

More information

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System MOBILE CALL GSM Alarm System USER S MANUAL System disarmed 00/00/00 00:00 ARM STAY CALL 1 2 3 4 5 6 7 8 9 Power Set Signal Alarm SOS ESC 0 ENTER Profile For a better understanding of this product, please

More information

X64 Wireless Training

X64 Wireless Training X64 Wireless Training IDS Contents 1 Contents Features 3 Wireless Hardware 4 IDS & Duevi integration PCB 5 LED operation 5 Wireless Device Hardware setup 6 Location 260 7 LED Keypad Instructions 7 Adding

More information

Training Manual with Bi-directional Wireless

Training Manual with Bi-directional Wireless Training Manual with Bi-directional Wireless Installer Training Firmware Version 2.7x X16 Stock Code: 860-1-473-X16 X64 Stock Code: 860-1-864-XS 2 IDS X-Series Training v2.7 Contents Contents 3 X-Series

More information

Added password for IP setup page : Password must be in IP format!

Added password for IP setup page : Password must be in IP format! NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP

More information

Paradox Integration Module Settings Guide

Paradox Integration Module Settings Guide Paradox Integration Module Settings Guide List of Terms used in Paradox Integration Module Settings Guide............. 3 Introduction into Paradox Integration Module Settings Guide............... 4 Configuration

More information

CA60Plus. Installation manual

CA60Plus. Installation manual CA60Plus Installation manual WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire

More information

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System MOBILE CALL GSM Alarm System GSM Alarm System System disarmed 11/26/2013 User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. CONTENTS

More information

Grandstream Networks, Inc. GDS3710 Input/output Alarms Configuration Guide

Grandstream Networks, Inc. GDS3710 Input/output Alarms Configuration Guide Grandstream Networks, Inc. Table of Contents INTRODUCTION... 4 GDS3710 WIRING CONNECTION... 5 Powering GDS3710... 5 Power and Data PINs... 5 Connecting Alarm IN and Alarm OUT PINs... 6 Alarm IN Connection

More information

GPS Evaluation Kit EVA1037/1080

GPS Evaluation Kit EVA1037/1080 GPS Evaluation Kit An evaluation system for Tyco Electronics GPS modules A1037-A & A1080-A User s Manual Version 2.0 Hardware Revision 01 This page was intentionally left blank. Revision History Revision

More information

GV2 Series Control Panels

GV2 Series Control Panels GV2 Series Control Panels EN Owner's Manual Supplement System Requirements Minimum system requirements for Classification in accordance with ANSI/SIA CP-01-2000: UL Listed and Classified control unit Model

More information

CBI-064. User Manual. Caddx to KNX-BUS Interface

CBI-064. User Manual. Caddx to KNX-BUS Interface CBI-064 Caddx to KNX-BUS Interface User Manual GDS Intelligence in Buildings El. Venizelou 116 Nea Erithrea 14671 Tel: +30 2108071288 Email: info@gds.com.gr Web: gds.com.gr Contents 1 Device Description...

More information

ELT-KLED EliteSuite LED Keypad Installation Manual

ELT-KLED EliteSuite LED Keypad Installation Manual ELT-KLED EliteSuite LED Keypad Installation Manual ELT-KLED EliteSuite Installation Manual PUBLICATION INFORMATION First Publication Draft Document Release Only Updated fire zone information Second Publication

More information

2000 Series. Program Entry Guide. Control Panels

2000 Series. Program Entry Guide. Control Panels 2000 Series EN Program Entry Guide Control Panels 2000 Series Program Entry Guide About This Manual EN 2 About This Manual This guide describes the programming parameters available to the 2000 Series Control

More information

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document 70072-0125-01 TECHNICAL NOTE NOVEMBER 2006 ION Meter Alerts A PowerLogic ION meter can send alerts to indicate a user specified power system condition such as a power quality problem (including surges,

More information

System. For a better understanding of this product, please read this user manual thoroughly before using it.

System. For a better understanding of this product, please read this user manual thoroughly before using it. GSM Alarm System User s Manual For a better understanding of this product, please read this user manual thoroughly before using it. Chapter 1. Features Chapter 2. Control Panel Introduction Chapter 3.

More information

PBI Manual. Paradox to KNX-BUS Interface

PBI Manual. Paradox to KNX-BUS Interface PBI 64-192 Paradox to KNX-BUS Interface Manual GDS Intelligence in Buildings El. Benizelou 116 Nea Erithrea, 14671 Phone: +30 2108071288 Email: info@gds.com.gr Web: gds.com.gr Contents 1 Device description...

More information

ModBus DE-1 INSTALLATION AND USER MANUAL

ModBus DE-1 INSTALLATION AND USER MANUAL ModBus DE-1 INSTALLATION AND USER MANUAL INTESIS Software, SL Distributed by DURAN ELECTRONICA S.L Tomás Bretón 50 28045 MADRID, España duran@duranelectronica.com www.duranelectronica.com 2 2010 DURAN

More information

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1 Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User

More information

See the table on the following Page for full descriptions of each Pin Type.

See the table on the following Page for full descriptions of each Pin Type. 8 Pin Comms-22-1 8 Pin Comms Task Format IMPORTANT NOTES: Hardware Compatability. The 8 Pin Comms Task can only be used in Type 2 (CE) Control Module Hardware. 22. Firmware Compatablility. INTRODUCTION.

More information

Galaxy Flex V3. User Guide. Honeywell Security. This user manual is located at

Galaxy Flex V3. User Guide. Honeywell Security. This user manual is located at Galaxy Flex V3 User Guide Honeywell Security This user manual is located at www.eaglesecuritysolutions.co.uk Contents Introduction... 5 Controlling your alarm system... 6 Users... 6 Panel control... 6

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

Contents. Glossary

Contents. Glossary Contents Glossary ------------------------------------------------------------------------------------------------------ 6 1. Introduction to the IDS 1632 -------------------------------------------------------------

More information

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide Digiplex System V2.14 / V2.2ACC Control Panel Programming Guide Table of Contents Getting Started...2 What Do I Do First?...2 How Do I Program the Control Panel?...2 Single Digit Entry Method...2 Multiple

More information

Halton SAFE / 7.14 user guide and installation instructions

Halton SAFE / 7.14 user guide and installation instructions Halton SAFE / 7.14 user guide and installation instructions VERIFIED SOLUTIONS BY H A LTO N Enabling Wellbeing Table of contents 1 System description 3 2 User Accounts 4 3 Main menu 7 3.1 Main menu - Change

More information

Ethernet General Purpose

Ethernet General Purpose Ethernet General Purpose Technical Manual Revision 1.03 8 November 2013 Pakton Technologies IO PAE224 Ethernet GPIO Manual.docx Page 1 of 22 Revision 1.03 Last updated 8/11/2013 Table of Contents INTRODUCTION...3

More information

System Galaxy Quick Guide

System Galaxy Quick Guide System Galaxy Quick Guide CONFIGURATION AND OPERATION Integrating CCTV with System Galaxy JAN 2019 SG 11.1.0.2 System Galaxy Quick Guide For CCTV Integration Configuration & Operation Information in this

More information

IntesisBox BACnet/IP Server - Notifier ID3000 series

IntesisBox BACnet/IP Server - Notifier ID3000 series IntesisBox Server - Notifier ID3000 series Gateway for integration of Notifier ID3000, ID3002, ID50 and ID60 fire panels into enabled control systems. Integrate your Notifier fire panels into your BACnet

More information

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0 User s Guide SUB-MA7240O-0001.OG.Solution40-111.doc Created: 6/05/03 Last Updated: 23/09/03 MA7240AO-0001 Version 1.0 2 Table Of Contents User List...6 Quick Reference..7 Features...7 Keypad User's Guide...8

More information

SETTING UP DSC INTEGRATION THROUGH ENTRAPASS

SETTING UP DSC INTEGRATION THROUGH ENTRAPASS DN1914-1005 SETTING UP DSC INTEGRATION THROUGH ENTRAPASS The purpose of this application note is to configure the EntraPass system to integrate with the DSC PowerSeries tm intrusion panel With EntraPass

More information

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual Revision 1.03 8 November 2013 JVA Technologies Ethernet General Purpose IO Technical Manual www.jva-fence.com.au Table of Contents INTRODUCTION...3 Scope and Purpose...3 Glossary...3 SPECIFICATIONS...4

More information

JA-63 Profi User manual

JA-63 Profi User manual JA-63 Profi User manual Contents: 1 Limited warranty... 2 2 Indicators... 3 3 Controlling the system... 4 3.1 Arming... 5 3.2 Disarming... 6 3.3 Panic Alarm... 6 3.4 To stop ALARM... 6 3.5 Home arming...

More information

HERCULES 6 GRAPHICS SYSTEM

HERCULES 6 GRAPHICS SYSTEM HERCULES 6 GRAPHICS SYSTEM USER MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273 Web: www.protec.co.uk

More information

PowerLogic ION Setup Meter Configuration Software Configuration Guide

PowerLogic ION Setup Meter Configuration Software Configuration Guide PowerLogic ION Setup Meter Configuration Software Configuration Guide 70002-0293-03 12/2010 Conventions Used in this Manual This section describes the symbols and terminology used in this guide. Symbols

More information

Training Manual Multi-Language with Wireless

Training Manual Multi-Language with Wireless Training Manual Multi-Language with Wireless Installer Training Firmware Version 2.3 X16 Stock Code: 860-1-473-X16 X64 Stock Code: 860-1-864-XS 2 Contents IDS X Series Training V2.3 Contents Contents 3

More information

IP & SMS Alarm Communicator

IP & SMS Alarm Communicator Models: WGSMSC You deserve to feel safe, secure & protected IP & SMS Alarm Communicator Quick Start Guide Thank you for purchasing a Watchguard IP & SMS Alarm Communicator This Quick Start Guide covers

More information

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual. Page : 1 of 17. ELAUSYS EVO-KNX KNX Interface for Paradox alarm system User Manual Document history Version. Date Author Comment 1.00 14-AUG-2017 NDE First issue Page : 2 of 17 TABLE OF CONTENT 1. INTRODUCTION

More information

1 Application Note Bosch Security Sys Sy tems m Bosch Security Systems Smart Safety Link -

1 Application Note Bosch Security Sys Sy tems m Bosch Security Systems Smart Safety Link - 1 Application Note Public Address Smart Safety Link PAVIRO and FPA configuration Bosch Security Systems Public Address Bosch Security Systems Public Address Application Note Smart Safety Link - PAVIRO

More information

Alarms Updated 03/26/2018

Alarms Updated 03/26/2018 Updated 03/26/2018 Table of Contents Alarms Alarms in OneView...1 Types of Alarms...1 Setting up Alarms...2 Alarm Configuration...4 Customize Alarm Parameters...5 List of Configured Alarms...7 Acknowledging

More information

Version 1.03 January-2002 USER S MANUAL

Version 1.03 January-2002 USER S MANUAL Version 1.03 January-2002 1 USER S MANUAL 2 Version 1.03 January-2002 System Details CUSTOMER:...... PHONE:... FAX:... INSTALLED BY:...... PHONE:... FAX:... MAINTENANCE & SERVICE:...... PHONE:... FAX:...

More information

User Manual. Dryer Controller M720

User Manual. Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009

More information

Other trade names mentioned in this document may be registered trademarks or trademarks of respective product manufacturers or vendor products.

Other trade names mentioned in this document may be registered trademarks or trademarks of respective product manufacturers or vendor products. Attention! Read this user manual carefully. Representative of the company installing the alarm system will explain which security module SP231 functions needs to be activated to ensure proper security

More information

3 User s settings. 3.3 Internal clock setting

3 User s settings. 3.3 Internal clock setting 2.9 Subsystem arming In a large building a sub control panel can be enrolled to the JA-63. The subsystem reports all alarms and failures to the main system. The installer can program if the systems will

More information

Dryer Controller M720

Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,

More information

Avigilon Control Center System Integration Guide

Avigilon Control Center System Integration Guide Avigilon Control Center System Integration Guide with Gallagher Command Centre INT-CARDAX-C-Rev3 Copyright 2013 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation

More information

D1255RB/D1256RB/D1257RB

D1255RB/D1256RB/D1257RB D1255RB/D1256RB/D1257RB EN Installation Instructions Fire Keypads and Fire Alarm Annunciator D1255RB/D1256RB/D1257RB Installation Instructions Listings and Approvals Listings and Approvals UL 365 UL 609

More information

Grandstream Networks, Inc. GDS3710 Input/output Connection Guide

Grandstream Networks, Inc. GDS3710 Input/output Connection Guide Grandstream Networks, Inc. Table of Contents INTRODUCTION... 4 GDS3710 WIRING CONNECTION... 5 Powering and Connecting the GDS3710... 5 Power and Data PINs... 5 Alarm In and Alarm Out PINs... 6 DETECT AND

More information

BURGLAR ALARM PANEL BS-468

BURGLAR ALARM PANEL BS-468 BURGLAR ALARM PANEL BS-468 Contents 1. Description... 3 2. Instructions for the user... 4 2.1Basic operations... 4 Complete system.... 4 Split system.... 4 2.2 Armed system indication... 5 2.3 Advanced

More information

Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren

Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren Quick Start This device is a combination of a Z-Wave sensor (smoke sensor) and a Z-Wave actuator. Pressing the button 'Inclusion Button' for one

More information

BOSCH GV4 Alarm Panel

BOSCH GV4 Alarm Panel System Galaxy Quick Guide CONFIGURATION AND OPERATION BOSCH GV4 Alarm Panel SG 10.2 (or later) NOV 2012 This is a Galaxy Product Interface Guide. Information in this document is subject to change without

More information

GLOBAL. InstallatIon & operation manual

GLOBAL. InstallatIon & operation manual InstallatIon & operation manual INDEX 1. INTRODUCTION... 5 2. FEATURES AND FUNCTIONS 2.1 Reporting Options... 2.2 Interfaces... 2.3 Programming... 2.4 Indicators and Controls...... 6 6 6 6 6 3. INSTALLATION...

More information

S INTRUSION&FIRE ALARM AND ACCESS CONTROL PANEL

S INTRUSION&FIRE ALARM AND ACCESS CONTROL PANEL S2000-4 INTRUSION&FIRE ALARM AND ACCESS CONTROL PANEL Installer s and User s manual S2000-4 INTRUSION&FIRE AND ACCEESS CONTROL PANEL ATTENTION! To modify configuration parameters use the program uprog.exe

More information

Fratech Multipath-IP

Fratech Multipath-IP Rev 2.0 (May 2013) Installer Manual 1 Current Part Numbers: Fratech Multipath-IP E-Link STU PCB & Accessory Kit only In Metal Enclosure with Power Supply 998325-PK 998325-XS Installer Manual This document

More information

Advisor Advanced Mobile Application User Manual

Advisor Advanced Mobile Application User Manual Advisor Advanced Mobile Application User Manual Content Warnings and Disclaimers 2 Advanced Mobile 2 Contact information 2 Description 2 Screen navigation 4 Gestures 4 Menu 4 Help navigation 4 Login 5

More information

rvm4c Installation Guide Remote Video Module

rvm4c Installation Guide Remote Video Module rvm4c EN Installation Guide Remote Video Module rvm4c Installation Guide Installation Diagrams EN 2 Installation Diagrams for the Transmitting Unit rvm4c Installation Guide Basic Hardware Installation

More information

Installation Instructions. Fire Command Center/Fire Alarm Annunciators D1256/D1257

Installation Instructions. Fire Command Center/Fire Alarm Annunciators D1256/D1257 Instructions Fire Command Center/Fire Alarm Annunciators D1256/D1257 74-06925-000-H Page 2 2004 Bosch Security Systems Contents 1.0 Introduction...5 1.1 Before You Begin...5 1.2 Type Styles Used Here...5

More information

AXI LED USER MANUAL (REV. 1.0)

AXI LED USER MANUAL (REV. 1.0) Security & Home Automation System AXI LED USER MANUAL (REV. 1.0) CONTENTS PREFACE FEATURES LED KEYPAD OUTLOOK 1.0 LIGHT INDICATION 1 2 4 6 CHAPTER 1: ALARM SYSTEM CONTROL 1.0 USING LED KEYPAD 1.0.1 ARMING

More information

Program version Alarm Control Panels PROGRAMMING GDAŃSK. versa_p_en 03/09

Program version Alarm Control Panels PROGRAMMING GDAŃSK. versa_p_en 03/09 Alarm Control Panels Program version 1.00 PROGRAMMING GDAŃSK versa_p_en 03/09 The SATEL's goal is to continually upgrade the quality of its products, which may result in alterations of their technical

More information

Protégé EliteSuite Eclipse LED Keypad Installation Manual ELT-KLES

Protégé EliteSuite Eclipse LED Keypad Installation Manual ELT-KLES Protégé EliteSuite Eclipse LED Keypad Installation Manual ELT-KLES The specifications and descriptions of products and services contained in this manual were correct at the time of printing. Integrated

More information

Engineer Reference. EN :2006+A1:2009 EN :2009 EN :2008 EN :2005+A1:2008 Security Grade 2 Environmental Class II

Engineer Reference. EN :2006+A1:2009 EN :2009 EN :2008 EN :2005+A1:2008 Security Grade 2 Environmental Class II EN50131-1:2006+A1:2009 EN50131-3:2009 EN50131-6:2008 EN50131-5-3:2005+A1:2008 Security Grade 2 Environmental Class II Engineer Reference INTERNAL SIREN WARNING The Enforcer 32-WE control panel contains

More information

/10 Rev A

/10 Rev A VISTA-128BPT/ VISTA-250BPT/ VISTA-128BPTSIA Commercial Burglary Partitioned Security System With Scheduling User Guide 800-06905 6/10 Rev A Your Honeywell security system is designed for use with devices

More information

UNC100 Integra Manual

UNC100 Integra Manual UNC100 Integra Manual New Generation Building Security July 30, 2014 V1.2 Copyright Notice Copyright 1995-2014 by All rights reserved Worldwide. Printed in Canada. This publication has been provided pursuant

More information

Control/Communicator

Control/Communicator Architectural & Engineering Specifications Control/Communicator 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality

More information

Avigilon Control Center System Integration Guide

Avigilon Control Center System Integration Guide Avigilon Control Center System Integration Guide with Gallagher Command Centre INT-CARDAX-C-Rev2 Copyright 2011 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation

More information

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160 All-In-One Wireless Security System V3.2 Programming Guide Model # MG6130 / MG6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com

More information

FS Mircom FX2000 Fire Alarm Panel

FS Mircom FX2000 Fire Alarm Panel Driver Manual (Supplement to the FieldServer Instruction Manual) FS-8705-16 Mircom FX2000 Fire Alarm Panel APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after May 1, 2001 Chipkin Automation

More information

Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A

Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A DS1067-062C Mod. 1067 LBT20063 REMOTE CONTROLLABLE ALARM CONTROL PANELS Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A USER MANUAL TABLE OF CONTENTS INTRODUCTION... 6 1 CONTROL DEVICES... 7 1.1 1067/022 keypad

More information

600 Range Dialer Installation Manual. Version 1.0

600 Range Dialer Installation Manual. Version 1.0 600 Range Dialer Installation Manual Version 1.0 The information contained is supplied without liability for any errors or omissions. No part may be reproduced or used except as authorised by contract

More information

VAP304 PRO INSTALLATION & OPERATION MANUAL

VAP304 PRO INSTALLATION & OPERATION MANUAL VAP304 PRO INSTALLATION & OPERATION MANUAL Panic Fire Duress Program Bypass Report Chime Test Memory B A D C Program Chime Panic Duress Exit Fire Report Bypass Memory Test Reset Password Exit Reset Password

More information

QUICK USER MANUAL. Alarm Control Panel. The full user manual and other manuals are available on

QUICK USER MANUAL. Alarm Control Panel. The full user manual and other manuals are available on Alarm Control Panel Firmware Version 1.09 QUICK USER MANUAL The full user manual and other manuals are available on www.satel.eu versa_ip_us_en 11/17 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND

More information

BURGLAR ALARM PANEL BS-468/A

BURGLAR ALARM PANEL BS-468/A BURGLAR ALARM PANEL BS-468/A Contents 1. Description... 4 2. User instructions... 5 2.1. Basic operations... 5 Complete System... 5 Split System... 5 2.2. Armed system indication... 6 2.3. Advanced operations...

More information

Watchguard WGAP864 User Manual

Watchguard WGAP864 User Manual Watchguard WGAP864 User Manual v1.0 Issued September 2016 1 2 Table of Contents Glossary... 5 1. Introduction to your Watchguard WGAP864... 6 2. Before Operating your Alarm System... 6 3. Understanding

More information

1. User features of the GSM dialer

1. User features of the GSM dialer 1. User features of the GSM dialer The JA60GSM dialer offers many useful features described in detail below. The installer should properly demonstrate the use of the system to the user after installation

More information

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68) F A 1 7 0 0 c Testing the System Battery Test When AC power is present, the FA1700C runs a brief battery test every 60 seconds to determine if there is a battery connected, and runs an extended battery

More information

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick CAN OBD READER REFERENCE DESIGN KIT USER GUIDE 1. Standard ToolStick Handling Recommendations The ToolStick Base Adapter and daughter cards are distributed without any protective plastics. To prevent damage

More information

Summit 3208GLD USER MANUAL. Electronics Line

Summit 3208GLD USER MANUAL. Electronics Line Summit 3208GLD USER MANUAL Electronics Line Table of Contents 1: Introduction... 2 2: Overview... 3 3: Keypad Functions... 4 3.1: Keypads... 4 3.2: 3108 LCD Keypad Layout... 4 4: Basic System Operation...

More information

Security System With Scheduling. User Guide. N5943-8V4 7/04 Rev A

Security System With Scheduling. User Guide. N5943-8V4 7/04 Rev A ADEMCO VISTA-120 Security System With Scheduling User Guide N5943-8V4 7/04 Rev A Your Honeywell security system is designed for use with devices manufactured or approved by Honeywell for use with your

More information

Welcome to MultiSight TM Vision Sensor Hands-On Lab

Welcome to MultiSight TM Vision Sensor Hands-On Lab Welcome to MultiSight TM Vision Sensor Hands-On Lab About This Hands-On Lab Welcome to the MultiSight TM Vision Sensor Hands-On Lab! This session provides you with an opportunity to explore the functionality

More information

Operator's Handbook. Interactive Fire Alarm System Release 3. Information Panel, BV-320. Protecting life, environment and property...

Operator's Handbook. Interactive Fire Alarm System Release 3. Information Panel, BV-320. Protecting life, environment and property... Interactive Fire Alarm System Release 3 Operator's Handbook Information Panel, BV-320 Protecting life, environment and property... ASAFE-IN/FE Rev. A, 010531 COPYRIGHT This publication, or parts thereof,

More information

Synergis Master Controller 2.2 Integration Guide for Assa Abloy Aperio- Enabled Locks

Synergis Master Controller 2.2 Integration Guide for Assa Abloy Aperio- Enabled Locks Synergis Master Controller 2.2 Integration Guide for Assa Abloy Aperio- Enabled Locks This guide supplements the Synergis Master Controller Configuration Guide and explains how to configure Assa Abloy

More information

Integrated Security Solutions

Integrated Security Solutions Integrated Security Solutions Table of Contents Control Panels 4 Keypads 8 Communication Modules 16 I/O Expanders 20 Door Control 24 Home Automation 25 RF Receivers 26 3 Our integrated security solutions

More information

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock. Preface Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock. The GSM Security Alarm ( The Alarm ) adopts the most advanced

More information

DESCRIPTION OF KEYPAD (Access module with segments)

DESCRIPTION OF KEYPAD (Access module with segments) DESCRIPTION OF KEYPAD (Access module with segments) For the most convenient control and status indication the JABLOTRON 100 system offers various types of access modules. Controlling (setting, unsetting

More information

PERMACONN PM1030 Includes DI300. Installation Manual

PERMACONN PM1030 Includes DI300. Installation Manual PERMACONN PM1030 Includes DI300 Installation Manual Radio Data Comms Unit 5/20-30 Stubbs Street Silverwater NSW 2128 Telephone: 02 9352 1777 Facsimile: 02 9352 1700 Introduction The PERMACONN system provides

More information

Smoke Detector and Siren. Manual

Smoke Detector and Siren. Manual Smoke Detector and Siren Manual 004001 Smoke Detector and Siren Manual Quick Start... 2 Product Description... 2 Installation Guidelines... 3 Behavior within the Z-Wave Network... 3 Operating the Device...

More information

General Purpose IO Technical Manual

General Purpose IO Technical Manual General Purpose IO Technical Manual Revision 1.06 8 November 2013 Pakton Technologies PAE222 GPIO Manual.docx Page 1 of 21 Revision 1.06 Last updated 8/11/2013 Table of Contents INTRODUCTION...3 Scope

More information

Instruction Manual Model Backup Switch, 1 for 8

Instruction Manual Model Backup Switch, 1 for 8 Instruction Manual Model 2582-282 Backup Switch, 1 for 8 December 2011, Rev. 0 MODEL 2582 SWITCH CROSS TECHNOLOGIES INC. SWITCH ALARM PSA PSB ALARM OFFLINE ONLINE UNIT STATUS 1 2 3 4 5 6 7 8 BU PROT MODE

More information

Sentient. Downloader Manual D4854

Sentient. Downloader Manual D4854 Sentient Downloader Manual D4854 Dycon Ltd Tel: +44 (0)1443 471 060 Fax: +44 (0)1443 479 374 Cwm Cynon Business Park Mountain Ash CF45 4ER - UK www.dyconsecurity.com sales@dyconsecurity.com TABLE OF CONTENTS

More information