LYNX CE CENTRAL CONTROL FOR OSMAC. General Specifications
|
|
- Lucy Nichols
- 6 years ago
- Views:
Transcription
1 LYNX CE CENTRAL CONTROL FOR OSMAC General Specifications Number of satellites: Up to 255 Number of satellite stations: up to 16,320 Number of Courses: 3 Number of holes per course: 48 Number of holes per system: 144 Number of areas per system: 99 Number of Area Programs per system: 999 Number of OSMAC satellite stand-alone Smart OSMAC programs: 12 Number of switch controls for automation of non-irrigation functions (lights, fountains, aerators, etc.): Unlimited 26 priorities (A-Z) assigned to Programs 7 Site Code categories with user defined names 1024 Hydraulic branches 6 Precipitation Management Groups (PMG) to refine flow management Up to 900 Instant Programs Supports up to 10 weather stations and up to 10 hydraulic sources Area, Hole, Sprinkler based Program Architecture with Dynamic Drill down to individual stations. Station Based Flow management for optimum system performance and reduce water time window Automated multi-level hydraulic flow and electrical systems management (Electro-Flow) Electro-Flowª simultaneously manages hydraulic and electrical demands in the system for total system efficiency Detailed, color-coded graphing of system projected flow Manual adjustment factors allow for scheduling refinement by station, hole, program, course and for site. Calculates and executes runtimes to the second Automated adjustment factors allow scheduling refinement from 0-900% Programmable weather station and pump station alarms: Up to 99 responses for any alarm Integration with Toro Turf Guard Soil Sensor system. Integration with Flowtronex Pace Pump Station, Flowtronex Pumplog software, Watertronics WaterVision software, Grundfos Pump Station with Toro-Grundfos Integration Service software. User-definable names versus system defaults Advanced multi-manual operations for overseeding, hot spots or fertilizer application (Station Groups and Master Group Multi Manuals) On-line, context-sensitive Help screens Advanced reporting capabilities: Provides informational displays of the central controller status, actual watering times per station, contents of the database, overview of scheduled irrigation activity Allows for graphical presentation of the system projected flow, an analysis of sensor data and water usage by the irrigation system Reports stations that are assigned to more than 1 program Reports for Water Usage, Weather data, Pump Station operation
2 Standard Hand-held radio capability Remote sprinkler activation by hardware address Pause and resume System test by hardware address Optional Hand-held radio capability Remote sprinkler activation by area and hole/area Runtime adjustment by percentage SGMM activation Control Code request Station Test by area Logging of manual irrigation on Course Report Digital paging communication mode Irrigation methods: Basic: daily run times or application amounts assigned to programs Intermediate: run times modified automatically with changes in daily ET, identified by ET source Advanced: run times calculated automatically based on sprinkler data, site parameters and measured ET Microsoft Windows 7 Ultimate operating platform True 100% 64-bit architecture Supports 16 languages: English, Bulgarian, Simplified Chinese, Czech, Danish, Dutch, French, German, Italian, Japanese, Korean, Norwegian, Portuguese, Russian, Spanish and Swedish Supports U.S and metric units of measure Runs on standard or premium computer (contact local distributor for current specifications) Integrated Map software allows: Dynamic, interactive operation Use of a non-scaled graphic image file Use of a scaled CAD generated map Enhanced graphics GPS compatibility for accuracy User Editing of Sprinkler, Satellite, Sensor, and Switch locations Floating of map onto secondary 1080P monitor Standard Weather Software allows: Automatic system adjustment using ET On-site or off-site weather station User-defined alarm thresholds Interactive, automatic response to the central Rain Shut Down and Rain Re-Flow alarm responses
3 Bidding Specifications Central Controller The central controller shall utilize a personal-computer-based, Microsoft Windows 7 Ultimate platform, userfriendly irrigation management and control program. The central controller shall utilize client/server architecture. Computer shall include 2 video outputs and allow map graphic to be floated onto secondary monitor. The central controller shall utilize site graphics with 64-bit software, including site graphics at the station level. The software shall be presented in a flat display, where all of the information needed is available to the user for a given operation, without having to open and close additional windows. The central controller shall have programs based on a hierarchy organized the same as the golf course. Course(s), Areas (greens, tees, fairways, etc.) followed by holes (1 through 48), followed by the individual sprinklers. The central controller shall have the ability to view the system at any of the four levels (course, area, hole, sprinkler) by Dynamic Drill down (simply clicking on a plus/minus box ) to give the user intuitive control. A graphic red Water Drop will identify areas and holes that have stations turned off. A graphic green Water Drop will identify areas, holes and stations set to run automatically. A graphic blue Water Drop will identify areas not scheduled to water. The central controller shall allow the user to schedule areas to irrigate by either entering runtimes in minutes, or by entering the amount of water to apply. If amount is utilized, the corresponding minutes will automatically be calculated and displayed. If minutes are utilized, the corresponding amount of application shall be calculated and displayed. Runtimes shall be calculated and executed to the second. The central controller shall have a Course Report to allow the user to determine the status of each sprinkler station on the golf course. The Course Report shall auto generate after each night s watering to allow confirmation of all sprinkler runtimes at a glance. The Course Report will display all Automatic, Manual, and Group Multi-Manual Irrigation as well as stations that are currently running. Stations that have not operated as scheduled shall be identified with a graphic red Water Drop. The Course Report / Alert Panel shall display feedback from the Base Station to indicate station status. Optional Hand-held Remote Interface (HHRI) will provide feedback for Manual operations. The Course Report will utilize the Area, Hole, Station layout with Dynamic Drill down to quickly navigate to exceptions. The central controller shall support the creation of a customized site map displaying multiple layers. The central controller shall allow the user to quickly create a map from any digital image (jpeg, bmp or tif format). The control system will allow the user to edit the locations of sprinklers, satellites, Turf Guard Sensors, and switches on the map. The central controller shall provide system status at the station level and display changes in status. The central controller shall be capable of creating user-defined work orders. If a CAD map is utilized, the central controller will display area and distance measurements. The central controller shall be capable of graphically displaying projected flow on the map at the station level and displaying station activation utilizing a color-coding system that shows how stations will activate during the next 24 hours. The central controller shall be capable of creating irrigation programs through the map and making station level percentage adjustments. When programming or manually running stations, the map shall be capable of automatically zooming into the stations, holes, and areas selected. The central controller shall have the ability to communicate with and control 255 OSMAC satellites with up to 64 stations for a total of up to 16,320 stations. The central controller shall automatically calculate sunrise and sunset based on longitude, latitude and date, and provide this information for starting or stopping a program in relation to sunrise or sunset.
4 The central controller shall permit true random access of all stations in the system and allow Instant Programs to be constructed with any combination of stations regardless of wiring sequences or satellite designation. The central controller shall have the ability to manually adjust (percentage increase/decrease) by course, area, hole, station, and/or the entire system. System adjustment factors may be input via actual percentage or operational ET. The central controller shall have the ability to connect to a weather station. The weather station will measure and store temperature, relative humidity, dew point, wind speed and direction, and solar radiation for use in the calculation of evapo-transpiration. The central shall have the ability to automatically calculate and adjust watering times based on evapo-transpiration. The central controller shall also have the ability to reduce the automatically calculated runtime by the rainfall measured over the preceding 24 hours. Further, the central controller shall have the ability to adjust calculated runtimes after they have been scheduled utilizing a Rain Re-Flow alarm response. The central controller shall include the Turf Guard Soil Sensor software. Individual sensor data can be assigned to specific sprinklers to allow the user to view current soil moisture on the Watering Plan, allowing the user to choose to skip watering if moisture levels are above user-defined thresholds, or to activate stations if moisture levels are below defined thresholds. The central controller shall employ advanced hydraulic/electrical systems management, allowing the user to specify hydraulic system design (sources and pipes representing mainlines, branches and flow groups) and the hydraulic limits of each entity. The central controller shall manage system flow by automatically generating the appropriate station start times based on the program priority and hydraulic limits set for each source and pipe, and for the electrical limit set for each field controller (satellite). The central controller shall incorporate the ability to use Precipitation Management Groups to specific which stations are allowed to operate simultaneously when hydraulic capacity is available. The central controller shall display projected flow by source, course, area, program and hole using colors to differentiate. The graph will calculate and display the maximum instantaneous flow as well as the total volume. Maximum flow and volume will be displayed in user-selected units. When pump integration is configured, the actual flow reported by the pump station can be displayed simultaneously with the projected flow for up to the last 7 days. The central controller shall have the ability to manually start programs for an entire area, a hole/area or an individual satellite program. Manual programs may be started in normal program time or a manually selected time. The central controller shall have the ability to start a multi-manual cycle in a satellite, running up to 6 stations simultaneously with a run time of up to 8 hrs 59 minutes. OSMAC satellites can run up to 16 stations simultaneously. The central controller shall have the ability to independently suspend, (hold) the automatic operation of an individual station, hole, area or the entire system. The station hold duration shall be programmable for the current irrigation day up to 30 days, or may be permanent. The central controller shall have the ability to control non-irrigation devices through switch outputs. Each switch will have an independent seven-day calendar schedule and start times for up to 12 starts. Switch outputs may run from one minute to 23 hours and 59 minutes (programmable in one-minute increments), with individual start times for each station (switch output). Switches may also be scheduled to run with any program and include the ability to offset the start time prior to or after the start of the program. The central controller shall allow a user-defined response to a weather station or pump station based alarm. The alarm response shall have up to 99 responses for local and globalized control. The OSMAC Base Station can be configured to support a Rain Shut down for the system.
5 The central controller shall provide reports detailing the following information: 1) projected schedule activity, 2) contents of the database constructed while programming the central controller, 3) overview of scheduled irrigation activity including start time, end time, area and satellite information, flow and program, 4) report stations that did not run, 5) stations that are assigned to more than one program. The central controller shall be capable of integrating with up to 10 pump stations manufactured by Flowtronex or up to 10 pump stations manufactured by Watertronics or up to 10 pump stations manufactured by Grundfos. The central controller shall be capable of displaying key pump station data including flow and pressure. The central controller shall be capable of responding to alarm conditions based on data received from the Flowtronex, Grundfos or Watertronics pump stations. When alarms are activated, the irrigation system will respond in one of the following ways: log only no response, pause irrigation, resume irrigation, turn a switch on/off, cancel a program or station, initiate a rain hold or cancel, start a program or initiate a Re-Flow response. The central controller shall have Power Guard, the ability to limit electrical consumption during specified times when integrated with a Flowtronex Pump station equipped with their Pace controls. The central controller will be able to limit flow during specified times with the configuration of a pump profile with or without pump station integration. These features allow savings in markets where the utility companies have adopted tiered electricity rates for peak use periods. The system shall require a personal computer which has been certified by the manufacturer for use with the central control system. The system shall come with a one-year dedicated support program provided by the manufacturer which includes extended warranties, 24-hour component replacement, toll-free help-line support and remote diagnostics by a licensed irrigator. The system shall include NSN Connect for secure remote access to allow the user to operate the Lynx system from any computer connected to the internet. This will also allow NSN to do remote diagnostics and support of the central controller. The system shall include one year of NSN Connect Plus, a service which will allow NSN to remotely monitor the computer 24/7/365 and will alert the user to internal computer hardware and software issues. The system shall include one year of Lynx Mobile, a service which will allow the user to remotely control Lynx 24/7/365 from any web enabled mobile device. This service will provide for manual irrigation, communication diagnostics, viewing of course status and alerts. The central controller shall be developed, manufactured, qualified and released in the USA by an ISO certified facility. The central controller, model number, shall be manufactured by The Toro Company, Irrigation Division, Riverside, California, USA. Note: Lynx, Electro-Flow, NSN, NSN Connect and NSN Connect Plus are trademarks of The Toro Company. Microsoft and Windows are registered trademarks of Microsoft, Inc.
6
LYNX SE CENTRAL CONTROL FOR NETWORK GDC. General Specifications
LYNX SE CENTRAL CONTROL FOR NETWORK GDC General Specifications Number of Gateways: Up to 4, each with up to 2 Station Groups Number of decoder stations: up to 500 Number of Courses: 1 Number of holes per
More informationDeltaV Analyze. Introduction. Benefits. Continuous automated DeltaV System alarm system performance monitoring
DeltaV Distributed Control System Product Data Sheet December 2016 DeltaV Analyze Continuous automated DeltaV System alarm system performance monitoring Trends of alarms, events, and user actions Identification
More informationSystem Description AutroMaster V Presentation System
System Description AutroMaster V Presentation System AMASTERV-SYSTEM/XGB, Rev. B, 2018-05-07, Autronica Fire And Security AS COPYRIGHT This publication, or parts thereof, may not be reproduced in any form,
More informationONYXWORKS AND FIRSTVISION. Version 4
ONYXWORKS AND FIRSTVISION Version 4 Version 4: Next Generation CONNECTED SOLUTIONS ONYXWorks FirstVision 2 ONYXWORKS Version 4 New to ONYXWorks v4.30 Look Ahead Test Monitoring Configuration Tool Display
More informationD-Link Central Management System
D-Link Central Management System This seamless management of digital video, audio and data is a powerful solution for large scale installations The D-Link Central Management System is a powerful system
More informationDeltaV Operate. Product Data Sheet DeltaV Operate December 2006 Page 1. Introduction. Benefits
December 2006 Page 1 You can easily manage your process with. Powerful operator interface, optionally up to four monitors Alarms prioritized by user Secure, standard operating desktop Intuitive graphics
More informationUsing ANM Mobile CHAPTER
CHAPTER 19 Date: 3/22/13 This chapter describes Cisco ANM Mobile, which allows you to access your ANM server or ANM Virtual Appliance and manage your devices using a mobile device such as an iphone or
More informationNetwork VP Sensor Input Kit (SIK) Installation Instructions
Network VP Sensor Input Kit (SIK) Installation Instructions The Sensor Input Kit receives sensor data from status, flow, temperature, rain buckets, and pressure sensors, then relays that data to the Lynx
More informationThermostat Guide Online Guide Brighten Conservation Program. Personal Reference Guide. Brighten ithermostat
Thermostat Guide Online Guide Brighten Conservation Program Personal Reference Guide Brighten ithermostat Thermostat Guide Online Guide Brighten Conservation Program Welcome to your new Brighten ithermostat
More informationPerimeter Product Overview. Effective protection for your business
Perimeter Product Overview Effective protection for your business The Gallagher difference Our innovation is driven by the desire to solve problems, meet your needs and provide real business value. We
More informationPowerWizard Range. Digital Control Systems & Remote Communication Options. PowerWizard Providing Safe Control of Your.
PowerWizard Providing Safe Control of Your Generating Set The Fg Wilson PowerWizard range of digital control panels combine straight forward menu navigation with advanced metering and protection technology.
More informationDigital Control Systems & Remote Communications Options
Digital Control Systems & Remote Options PowerWizard Providing Safe Control of Your Generating Set PowerWizard 1.0 and 2.0 The Olympian PowerWizard range of digital control panels combine straight forward
More informationHikCentral Specification. HikCentral V1.1.1 Specification
HikCentral V1.1.1 Specification Introduction HikCentral is a flexible, scalable, reliable and powerful central video system. HikCentral provides central management, information sharing, convenient connection
More informationTORO SENTINEL APPLICATION NOTE AN04: ACTIVITY / ALARM MONITOR
TORO SENTINEL APPLICATION NOTE AN04: ACTIVITY / ALARM MONITOR Version: 1-26-2011 ACTIVITY / ALARM MONITOR IN SENTINEL Activity / Alarm Monitor Overview The Activity/Alarm Monitor screen combines the separate
More informationIntelligent alarm management
Intelligent alarm management icontrol Web s Advanced Alarm Management enables operators to work together to identify and resolve facility faults to minimize the MTTR. icontrol Web offers Advanced Alarm
More informationArchitectural and Engineering Specification for a Security Management System. StarNet 2
Architectural and Engineering Specification for a Security Management System StarNet 2 Jan 2, 2018 Page 1 of 12 AE-S2-IN-R1-EN-01/18 This document is intended to provide performance specifications and
More informationSamsung SDS BMS Ver.2.0. Technical Specification
Samsung SDS BMS Ver.2.0 Technical Specification Technical Specifications All rights and title, including all intellectual property rights to Samsung SDS BMS" is retained by Samsung SDS Co, Ltd. ("SDS"),
More informationDeltaV Live. Introduction. Benefits. Modern, built-for-purpose operations experience
DeltaV Distributed Control System Product Data Sheet December 2018 DeltaV Live Modern, built-for-purpose operations experience Easily create intuitive displays, with minimal to no scripting required Robust,
More informationMonitoring Software for NPBC-V3M-1 User Manual
Monitoring Software for NPBC-V3M-1 User Manual User Manual ver 1.5 page 1 of 14 Contents: 1. Introduction... 3 2. Requirements... 3 3. Installing the software... 4 4. Connecting the devices... 4 5. Updating
More informationby Honeywell WINMAG THE ULTIMATE VIGILON TEXT AND GRAPHICS SOFTWARE
WINMAG THE ULTIMATE VIGILON TEXT AND GRAPHICS SOFTWARE by Honeywell WINMAG, The Ultimate Vigilon Text And Graphics Software WINMAG offers the best possible integrated visual data and management solution
More informationArla Tank Guard. Technical Specifications For Arla Tank Guard
Technical Specifications For Arla Tank Guard Tank Guard Purpose The purpose of installing a tank guard is to monitor milk cooling and storage for the benefit of both the milk producer and the dairy. The
More informationAdvanced Facility Air-Management Technology
Internet-Enabled HVAC Monitoring & Control Maximum Digital Precision & Total Configuration Flexibility Pure and Simple Solutions Advanced Facility Air-Management Technology AbsolutAire s Facility Air-Management
More informationSmarTemp Control fx 2.0
Digital Timer Interface Installation / Operation Instructions General Thank you for choosing Webasto to meet your heating needs. The Webasto SmarTemp Control fx 2.0 enables you to preset start-up cycles
More informationWiser Air User Interface Guide. Thermostat
Wiser Air User Interface Guide Thermostat 2 User Guide Wiser Air Scope This document outlines the user interface features of the Wiser Air smart thermostat. It is intended to support individual users and
More informationCOMFORT IP: Room Control Unit Radio with Display
COMFORT IP: Room Control Unit Radio with Display The COMFORT IP Room Control Unit Radio with display registers the room temperature and the humidity in the assigned heating zone and regulates it via connected
More informationNo part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic,
No part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic, mechanical, by photocopying, recording or in any other manner
More informationTHX-DL Data Logger USER & INSTALLATION MANUAL V
THX-DL Data Logger USER & INSTALLATION MANUAL V1.2012 www.thermomax-refrigeration.com Contents PRESENTATION Summary of Features 2 INSTALLATION Safety Precautions 4 THX Unit 4 Sensors 4 Alarm Relay 4 Power
More informationTech Data Sheet D01662GB0_Esgraf 4.1 and Configuration Server 30/2011 2/(5)
Tech Data Sheet D01662GB1_Esgraf 4.1 and Configuration Server 30/2011 1/(5) Esgraf 4.1 graphical user interface, configuration server and fire detectors contamination monitoring Esgraf 4.1 ESGRAF is a
More informationDeveloping a Model Irrigation Dissemination Program for Homeowners
Developing a Model Irrigation Dissemination Program for Homeowners Charles Swanson, Extension Program Specialist-Landscape Irrigation Texas A&M AgriLife Extension Service 2117 TAMU, College Station, Texas
More information[ [ ADMIN PANEL USER GUIDE
[ [ ADMIN PANEL USER GUIDE ADMIN PANEL USER GUIDE 2 Contents Logging In & Systems Overview 3 System Details 5 Analytics 6 View Alarms 8 Manage Alarms 9 Create Alarms 10 Device Reporting Alarm 11 Monthly
More informationBoztek Solutions` PLAYSTATE
Boztek Solutions` PLAYSTATE REMOTE MONITORING & CONTROL SYSTEM FOR PLAYING FIELDS & OPEN SPACE Contact Details: Boztek Solutions Pty Ltd PO Box 272, Windsor, NSW 2756 Unit 12/124 Ham Street, South Windsor,
More informationDeltaV Operate. DeltaV Operate. Introduction. DeltaV Product Data Sheet. Robust and secure plant operations
February 2016 Page 1 DeltaV Operate You can easily manage your process with. Robust and secure plant operations Powerful operator interface, optionally up to four monitors Constant visibility and access
More informationApplication description
Application description Application description Hersteller KNX Touch Control Hager Displays Touch Displays ETS Touch Control Order number Product designation Application programme TP product SWDT03 WDT030
More informationGallagher Perimeter Product Overview
Gallagher Perimeter Product Overview 1 security.gallagher.com Gallagher is a global leader in the innovation, manufacture and delivery of security solutions. Meeting our customers needs inspires us to
More informationWS3650IT-MG-SIL. Technical sheet
Technical sheet This professional Weather Center brings weather watching to a new level. Includes touch screen display, indoor and outdoor temperature and humidity, anemometer, rain gauge and PC Connection
More informationRC-1000 and RC-2000 Programmable Communicating Thermostat. User s Guide
RC-1000 and RC-2000 Programmable Communicating Thermostat User s Guide Contents About your thermostat... 1 Features:...1 Getting to know your thermostat s controls... 2 Getting to know your thermostat
More informationLynx Smart Satellite Sensor Kit
Lynx Smart Satellite Sensor Kit Installation and User Guide The Lynx Smart Satellite Sensor (LSSS) Kit receives data from flow, temperature, and pressure sensors, as well as switches and rain buckets.
More informationONYX FirstVision Specification Interactive Firefighters Display
ONYX FirstVision Specification Interactive Firefighters Display NOTIFIER is a registered trademark, and ONYX FirstVision, NOTI FIRE NET, and VeriFire are trademarks of Honeywell International Inc. Microsoft
More informationUSER S GUIDE. AXIS Cross Line Detection
USER S GUIDE AXIS Cross Line Detection User s Guide Rev. 1.00 Copyright Axis Communications AB, 2009 November 2009 Part no. 36687 AXIS Cross Line Detection AXIS Cross Line Detection is a trip-wire application
More information1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...
User Manual Contents 1 DOCUMENT REVISION... 4 2 SOFTWARE VERSION... 4 3 BASIC DESCRIPTION... 4 4 BASIC OVERVIEW OF HYDRAULIC DIAGRAMS... 5 4.1 BOILER NOT CONTROLLED BY THE CONTROLLER:... 5 4.2 BOILER CONTROLLED
More informationMilestone XProtect. Central 3.7 User s Manual
Milestone XProtect Central 3.7 User s Manual Target Audience for this Document This document is intended for end users of the Milestone XProtect Central surveillance system monitoring solution, such as
More informationIDEAL E-NERGY Thermostat Touch type User Manual
67800 03/18 (JRK) IDEAL E-NERGY Thermostat Touch type 203250 User Manual WWW.MFH-SYSTEMS.COM Contents Menu Overview............... 3 Introduction................. 4 Startup Wizard 1/2.............. 5 Startup
More informationCardax System Comparison
System Comparison Hardware FT Series 5 Syst Com 131102 Syst Com 131102 2 Contents 1. Introduction... 5 2. System Diagrams... 7 3. Hardware Comparison... 10 4. Comparison... 11 Syst Com 131102 3 Syst Com
More informationTHERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!
THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world! FOR ALL YOUR TEMPERATURE AND HUMIDITY CONTROLS, PRODUCT TRACKING, TRANSPORT, STORAGE CONTROLS, HACCP! Small, rugged,
More informationA new view on building protection. Cerberus DMS makes building protection smarter, easier and more flexible. Answers for infrastructure.
A new view on building protection Cerberus DMS makes building protection smarter, easier and more flexible. Answers for infrastructure. Safety made easier. As an easy-to-use system with a single point
More informationPowerRouter application guideline
PowerRouter application guideline Software installation tool - version 3.4 Before operating the PowerRouter, you may initialize the PowerRouter by using the PowerRouter software installation tool. The
More informationThe Centron Presidio Monitoring System. Centron. Presidio. Rees Scientific. An ISO 9001:2008 Company
The Monitoring System Rees Scientific An ISO 9001:2008 Company About Rees Scientific Rees Scientific specializes in protecting your valuable assets. Since 1982, Rees Scientific has been the industry standard
More informationPatriot Systems Limited
COPYRIGHT 1997 - The Patriot Systems Ltd. Patriot Alarm Monitoring Automation Package is licensed for use on one computer, by the original person, or company, or organization whose name is registered with
More informationALARM MANAGER. 1. About the Alarm Manager... 4
1. About the Alarm Manager... 4 2. Overview of the Alarm Manager... 5 2.1 Alarms and groups... 5 2.2 Display of alarms... 5 2.3 Triggers... 5 2.3.1 Alarms not yet triggered... 6 2.3.2 Alarm triggered,
More informationINTELLICOMFORT CH180WIFI TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION FOR REMOTE CONTROL
PROGRAMMABLE THERMOSTATS, THERMOSTATS AND TEMPERATURE CONTROLS INTELLICOMFORT CH180WIFI TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION FOR REMOTE CONTROL Weekly program To control the heating
More informationCompact Product Suite Compact HMI 6.0 Overview ABB
Compact Product Suite Compact HMI 6.0 Overview ABB 2 OVERVIEW COMPACT HMI VERSION 6.0 Compact HMI A feature-rich human-machine interface Another feature is the high performance prefabricated, reusable
More informationHMI of the Future with Experion Orion Console and Experion Collaboration Station Andrew Stuart & Annemarie Diepenbroek, Honeywell
1 2014 Honeywell Users Group Europe, Middle East and Africa HMI of the Future with Experion Orion Console and Experion Collaboration Station Andrew Stuart & Annemarie Diepenbroek, Honeywell Challenges
More informationARCHITECTURAL AND ENGINEERING SPECIFICATION
ARCHITECTURAL AND ENGINEERING SPECIFICATION Access Control System ACTpro Vanderbilt Industries, Clonshaugh Business and Technology Park, Dublin, D17 KV84, Ireland TABLE OF CONTENTS PART 1 GENERAL 1.1 System
More informationHI 8001 & HI 8002 Panel-mounted and Wall-mounted Fertigation Controllers
Instruction Manual HI 8001 & HI 8002 Panel-mounted and Wall-mounted Fertigation Controllers Manufacturers since 1978 These Instruments are in Compliance with the CE Directives 1 Dear Customer, Thank you
More informationEnergyMaster. ENEC Monitoring System. An on-site supervision and remote monitoring solution
EnergyMaster ENEC Monitoring System An on-site supervision and remote monitoring solution ENERGYMASTER ENEC MONITORING SYSTEMS AN ON-SITE SUPERVISION AND REMOTE MONITORING SOLUTION Take Control of Your
More informationPatriot Systems Limited
COPYRIGHT 1997 - The Patriot Systems Ltd. Patriot Alarm Monitoring Automation Package is licensed for use on one computer, by the original person, or company, or organisation whose name is registered with
More informationC. The system shall be capable of turning luminaires on/off (where supported by the luminaire) as well as full range dimming.
SECTION 260943 SPECIFICATIONS - Wireless Network Lighting Controls. PART 1 - GENERAL 1.1 RELATED DOCUMENTS 1.2 SUMMARY AND KEY SYSTEM DIFFERENTIATORS A. The lighting control system specified herein shall
More informationEKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual
EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING Manual Contents Introduction...3 Valve compatibility...3 Features...3 Application examples...3 Ordering...3 Operating the EKC 347...4-5
More informationSIMPLIFIED HOME SECURITY AND CONTROL
SIMPLIFIED HOME SECURITY AND CONTROL HOME CONTROLLER USER GUIDE HOME CONTROLLER Mediacom introduces a whole new level of security for the things that matter most in your life. Whether you re home or away,
More informationAUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12
AUTOMATION P R O D U C T S GROUP, INC. Operator s Manual RST-5000 Series Web Enabled Input Module Rev. A2, 1/12 Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com RST-5000
More informationAdvanced Lighting Control for High Building Performance
www.sylvania.com Advanced Lighting Control for High Building Performance Better Buildings by Design Kandice Castellino February 2014 Burlington, VT Why Advanced Lighting Controls? Controls Greater energy
More informationPYROSOFT. Software for DIAS infrared cameras in industry and research & development. Standard and application specific software Overview & Features
PYROSOFT Software for DIAS infrared cameras in industry and research & development Standard and application specific software Overview & Features w w w. d i a s - i n f ra r e d. d e PYROSOFT Compact,
More informationManaging Network Alarms and Events
10 CHAPTER Prime Performance Manager allows you to view alarms and events that occur in your network. The following topics provide information about displaying network alarms and events: Displaying Active
More informationIon Gateway Cellular Gateway and Wireless Sensors
Page 1 of 9 Account & Network Setup If this is your first time using the Ion Gateway online system site you will need to create a new account. If you have already created an account you can skip to the
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL
PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Minimum lighting control (base scope of work) shall include all corridors. The lighting in all the corridors shall be turned on (if not already on) if
More informationFacility Commander Complete, Integrated Command and Control
Facility Commander Complete, Integrated Command and Control 2.0 Facility Commander Complete, integrated command and control Securing your business facilities requires multiple systems, often from different
More informationMADE TO PROTECT INT-TSI. touchscreen keypad. intelligent alarm system control center
MADE TO PROTECT INT-TSI touchscreen keypad intelligent alarm system control center Control center UNLIMITED INTERACTI POSSIBILITIES REMOTE CTROL intelligent alarm system FLEXIBILITY AND VERSATILITY OF
More informationInnovative protection that combines power and flexibility
Innovative protection that combines power and flexibility Desigo Fire Safety Modular outpaces industry standards and includes cutting-edge detection and communication capabilities usa.siemens.com/desigo-fs-modular
More informationRotem One Touch. User Manual PRELIMINARY DOCUMENT. Ag/MIS/UmGB /18 Rev 1.0 P/N:
User Manual Rotem One Touch Rotem One Touch Ag/MIS/UmGB-2603-06/18 Rev 1.0 P/N: 110741 Rotem One Touch User Manual Revision: N.1.0 of 02.2018 Product Software: 7.14 This manual for use and maintenance
More informationMultiRAE Lite. Wireless Portable Multi-Gas Monitor
MultiRAE Lite Wireless Portable Multi-Gas Monitor The MultiRAE Lite is an optimal one-to-six 4 -gas monitoring solution for personal protection (including confined space entry) and multi-gas leak detection
More informationAS950 PORTABLE SAMPLERS
AS950 PORTABLE SAMPLERS Applications Wastewater Collections Industrial Pretreatment Environmental Monitoring Stormwater Sampling has never been this easy. The AS950 Portable Sampler makes programming,
More informationDaily Offsite; 30 days of backup available; Offsite Annual backup maintained for 5 years
The fire and gas mapping software is the most technically sophisticated and accurate application available. The fire and gas engineering and risk analysis experts at have engineered this software tool
More informationEcoView Energy Management System
EcoView Energy Management System EcoView Energy Management System What is it? Energy Management Systems (EMS) reduce energy usage and save money by improving the efficiency of a facilities highest-energydemand
More informationB and G Series Integrated Security Solution
B and G Series Integrated Security Solution Integrated Security Solution Greater protection B and G Series Control Panels are approved for combination burglar and fire alarm applications (UL certified),
More informationPotterNet Fire & Facility Supervising Station
Features Connect up to 1000 Potter panels in a single building, local campus, or multiple sites worldwide using LAN/WAN/Internet Native Ethernet networking connectivity with fire panels and client stations,
More informationDifferent types of Fire Alarm System
Different types of Fire Alarm System Conventional Fire System Generally comes with Zones. Each zone can have max 20 detectors. Addressable Fire Alarm System This comes in loops. Different manufacturer
More informationInteractive Fire Control Panel IFS7002 one signal loop Instruction Manual
Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Revision 4/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...
More informationPM-ANALYZE. Overview 1. System Configuration 2. Operation 3. Analysis of Alarms and process values. User Interface 4
Overview 1 System Configuration 2 Operation 3 Analysis of Alarms and process values User Interface 4 Version 8 Configuration 5 Edition: 04/04/2017 Table of Contents Contents 1 Overview... 1-1 1.1 General
More informationthe connected Moving to home
www.io-homecontrol.com io-homecontrol - 09/2014 BC-EN - Illustrations Orlando Hoetzel - io-homecontrol and the io-homecontrol logo are registered trademarks by the io-homecontrol association - SOMFY.COM141000
More informationFastReporter 2 DATA POST-PROCESSING SOFTWARE
DATA POST-PROCESSING SOFTWARE Consolidated data management and post-processing tool designed to increase the reporting productivity for connector endface inspection and all types of optical-layer testing:
More informationGMS GRAPHICAL MANAGEMENT SYSTEM
GMS GRAPHICAL MANAGEMENT SYSTEM 1 GMS Security management system for multi-site organizations. PACOM Graphical Management System (GMS) is the modular client-server application that integrates all of PACOM
More informationGilian Air Sampling Products. The World s Most Reliable Air Sampling Equipment
Gilian Air Sampling Products The World s Most Reliable Air Sampling Equipment Overview of Sensidyne Established in 1983 Joined the Schauenburg Group in 2008 Major Product Groups: Air Sampling * Fixed Gas
More informationREMOTE MONITORING AND ALARM SYSTEM
FUNCTIONALITY A. The water and wastewater facilities remote monitoring, reporting and alarm notification system shall be comprised of a hosted, Web-based user-interface which communicates to remotely monitored
More informationMilestone XProtect Alarm Matrix Integration 1.0
Milestone XProtect Alarm Matrix Integration 1.0 Milestone XProtect Alarm Matrix Integration 1.0 Target Audience This document is aimed at system users and provides descriptions on how to install, configure
More informationOrganize your security with PSIM + software
Organize your security with PSIM + software WHAT IS PSIM SOFTWARE? Functional scope of a Physical Security Information Management System Application In practice, the WinGuard platform is collecting all
More informationDew point set DS 400
set DS 400 Dew point set DS 400 for stationary dew point monitoring of refrigeration or adsorption dryers. The touch screen graphic display enables an intuitive operation and shows the progress of the
More informationOracle Retail Merchandising System Release Notes Release 12.0 May 2006
Oracle Retail Merchandising System Release Notes Release 12.0 May 2006 Copyright 2006, Oracle. All rights reserved. The Programs (which include both the software and documentation) contain proprietary
More informationPractical Distributed Control Systems (DCS) for Engineers & Technicians. Contents
Practical Distributed Control Systems (DCS) for Engineers & Technicians Contents Chapter 1 Introduction to Computer Based Control Systems 1 1.1 Introduction to computer based measurement and control systems
More information2017/11/16 P a g e 1
2017/11/16 P a g e 1 Contents What s New... 2 Fixes... 3 Driver Updates... 3 New Sensors... 3 New Features... 3 How To... 4 Security... 4 Auditing... 6 Smart UI/MAPS Title 21 CFR Part 11 Auditing... 6
More informationHoneywell Total Connect Remote Services
Honeywell Total Connect Remote Services Basic User Guide With Honeywell Total Connect Remote Services, you can stay connected and in control of your home or business whenever you want, wherever you are.
More informationSmart Energy Programmable Thermostat + Energy Monitor. EE542-1Z I User Manual
Smart Energy Programmable Thermostat + Energy Monitor EE542-1Z I User Manual Contents 1 1.0 Welcome! 2 2.0 Get to Know Your Thermostat 3 3 4 4-5 2.1 Use the Navigation Keypad 2.2 Initiate a Temporary Hold
More informationWelcome to a world where technology flows through the heart of your business environment. Welcome to CDC
Welcome to a world where technology flows through the heart of your business environment Welcome to CDC Introduction to Integra 4 Integra configuration 4 Graphical Supervisor 6 Integra difference 8 Integra
More information- Data Brochure Steam Control 279
- Data Brochure Steam Control 279 D 279 12/07 The tekmar Steam Control 279 can operate a single on-off steam boiler or an on-off steam valve using outdoor reset. The control determines the on time of the
More informationFacility Commander Wnx
Facility Commander Wnx Integrated security management platform for Windows Seamless. Effective. Efficient. Integrate security applications on one versatile platform It s easy and efficient to seamlessly
More informationSmart Hub. Connecting people, connected care. What is it? Who is it for? How does it work?
Smart Hub Connecting people, connected care What is it? The Lifeline Smart Hub is a complete Connected Care monitoring and alarm system for the home. It uses future proof, smart technology to connect service
More informationGE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring
GE Security FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring Version v2-2 / September 2005 Aritech and Kilsen are GE Security brands. http://www.geindustrial.com/ge-interlogix/emea
More informationUtilizing GPS to Increase Performance. Murray Lodge Topcon Positioning Systems
Utilizing GPS to Increase Performance. Murray Lodge Topcon Positioning Systems Using GPS to Increase Productivity Where and how is it used? GPS on the construction jobsite Telematics Mapping Grade management
More informationNetbiter Tank Sensor
For Netbiter Tank Sensor HMS Industrial Networks AB Post address: Box 4126 300 04 Halmstad SWEDEN Visitor s address: Stationsgatan 37 302 45 Halmstad SWEDEN Telephone: + 46 35 17 29 00 Fax: + 46 35 17
More informationThermoControl 0 C - 10 C - 20 C - 30 C
ThermoControl Product and Quality Reliability Alarm Functions & Documentation Global Monitoring 0 C - 10 C - 20 C - 30 C Global monitoring: global temperature measurement and real-time monitoring using
More informationEZT-570S Touch Screen Controller The Next Generation Controller with Smartphone Technology
EZT-570S Touch Screen Controller The Next Generation Controller with Smartphone Technology www.cszindustrial.com EZT-570S Touchscreen Controller The Next Generation Controller with Smartphone Technology
More information