1 User Manual 120/240/300 Outdoor Motion Detector Swiss Garde 4000

2 Warning! - Any work on the main power supply must only be completed by trained specialists. - The product must be installed in accordance with installation guidelines/standards specific to your country. - Disconnect the 230V power supply before starting the installation process. - As a precautionary measure, the power supply of the light should always be fitted with a (250VAC, 10A) type C fuse in accordance with EN Faulty lamps may cause a short-circuit and thereby permanently damage the device. - Disconnect power prior to replacing a lamp. - To ensure the operational reliability of the detector, keep a minimal distance of 1m to lamps installed on the same height level. - Lamps installed underneath the detector or in the detection area may disturb the functionality. Keep detector away from heating devices. - In case of malfunction, such as continuous lighting, or false triggering please refer to the troubleshooting section on page 9. Function The detector reacts to the motion of heat (positive or negative in relation to the environment). If a person approaches the monitored area, the device will turn on the connected light automatically. If the person leaves the area, the light will be switched off after the preset duration (short impulse, 10 sec. to 20 min.). The connected light will be turned on only when the ambient light value is below the adjusted value. Installation site Install the device protected from weather conditions to maintain operation reliability and product lifetime. Respect a minimum distance of 1 m to lights fitted on the same height level. Lights mounted underneath the detector but within the detection area may impair its function. Please check the trouble shooting section for further details. 2

3 Mounting height 1. Standard mounting height 2.5 m. For efficient pet tolerance functionality, we recommend a mounting height of 2.2 to 3 m. Check range by walking around in the detection area. Depending on site conditions, it might be necessary for the detector head to be tilted down one step or to be rotated by ± 10 from a mounting height exceeding 2.8 m. 2. Tilting detector head towards the ground impairs pet tolerance functionality. Directing the rear view observation lens towards the sky (240 and 300 models only) will not detect persons but will increase probability of malfunctions. In case of such an application, the lens should be covered with the louvre clips included in the scope of supply (see picture on page 4). 360 ceiling mount detection area Swiss Garde SG detection area, ideal in garages, corridors, etc. Pet tolerance functionality deactivated. 3

4 Mounting socket Louvre clips Use to cover up unwanted detection areas Installation Wire the detector as follows: phase/outer conductor (L) brown; neutral/neutral conductor (N) blue; switching output / switched phase/ outer conductor (L ) red The removal of bridge L/D1 makes contact D1/D2 potential free. Optional: remote switching (R) via (supply of the phase) impulse switch (no neon bulbs!). Keep cables short! Capacitive currents at terminal (R) may trigger malfunctions. Earth conduct, earth wire (green/yellow) = not required The device is operational after approx. 1 minute from connecting to mains voltage. After this duration the detector can be programmed either by P-IR remote control or by manipulating potentiometers. No manipulations will become effective during start-up. Remove socket from device: Gently press clips 1+2 to remove device. Corner-mount socket included in 300 version opt. accessories for 240 /120 versions: item no white item no aluminium item no black 4

5 Connecting electrical loads High inrush currents will considerably shorten the lifetime of the detector s in-built relay. Please verify the technical data provided by the lamp or luminaires manufacturer concerning inrush currents, specifically with compact fluorescent, fluorescent lamps, electronic ballast, etc. in order not to overload the internal relay. We recommend connecting a maximum of three to four motion detectors in parallel. If the number of switching cycles is above average or in the event of increased (inductive) loads, we recommend using the short pulse function on the motion detector and switching the load via an external staircase timer switch or contactor. Keep cables lengths to a minimum in order to prevent capacitive standby current. Wiring diagrams Standard installation. Optional push button connection (R) for manual switching. Removing bridge L/D1 makes contact D1/D2 potential free. Several devices in parallel in short impulse mode (max. 3 to 4 devices) connected to a staircase switch or relay. 5

6 Several detectors connected in parallel, with additional wall switch to enable permanent lighting. Installation of an RC element, (between neutral conductor (N) and switched phase L ) in case of interferences by fluorescent lamps (switch-off sparks) or by several detectors connected in parallel (caused by capacitive current in the wires). Varistor (between neutral conductor (N) und phase (L)) to reduce mains voltage peaks. Swiss Garde 4000 end-user remote control standard detection pet tolerance functionality, animals will not be detected, creep zone protection deactivated, sensitivity reduction (see detection area on p. 8) Stage 1: keep button pressed for 0.1 to 2s, max. range 9 m Stage 2: keep button presse for 2 to 5 s, max. range 6 m Auto Test Automatic mode (default) detection area check with short delay time, switches to automatic mode after 5 min. ON/OFF switch light permanently ON/OFF for 6 hours (device automatically returns to automatic mode. Does not work in impulse mode. Operating mode standard/pet tolerance may be activated by remote or manually on the device and will stay intact even if adjusted manually or by remote control. 6

7 Controls LED, flashing once upon detection, three times upon adjusting TIME or LUX values, or receiving a command from the remote control. Accessory: maintenance remote Attention! LUX or TIME value adjustments during a stable working condition will be stored and become valid immediately. Any values adjusted by remote control will be overridden. Either manual values or values by remote control may be active, mixing is not possible Standard/pet tolerance mode will be kept during adjustments. Device control allows for pet tolerance stage 1 only (stage 2 with remote only). SENS (sensitivity/range) Detection range adjustment max = approx. 16 m frontal, 16 m lateral. Should the detector be too sensitive (triggering without movement in the detection range), the sensitivity/range can be reduced. TIME The timer determines for how long the lights will remain on following the last movement in the detection area. Choices are between short impulse (approx. 1 sec, approx. 20 sec. / 60 sec. break, selectable by remote control only) and time delay (approx. 10 s to max. 20 min.). The in-built Eco function will automatically reduce delay time to 3 minutes even if set higher if a movement is detected for less than 30 seconds. LUX (twilight sensor) The twilight sensor regulates the operating threshold (light value) of the detector determining when the device should be activated. Minimum value 5 lux (moon symbol): The detector will turn on the light at night. Maximum value 2000 lux (sun symbol): The detector will turn on the light during daytime as well. Recommendation: approx. 5 lux in staircases, 50 lux outdoors 7

8 Detection range The 300 /240 /120 detection range with 360 creep zone protection as well as the tight detection area allow for an optimal function. The range depends on the installation height and walking direction (high sensitivity when cutting or changing a switching segment). Since the detector reacts to temperature differences between heat source and ambient temperature, the response may vary depending on the installation site (floor heating, hot environment, etc.). top view frontal approach NOT SENSITIVE detection range = ca. -50% tangential approach SENSITIVE side view * creep zone protection deactivated stage 1: 9 m max. range stage 2: 6 m max. range 8

9 Troubleshooting error light does not turn on: cause/amendment - twilight adjustment value too low - connected lamp defective - check mains power / fuses detector triggers without reason - check detection area for potential reason / light never turns off: causes of false triggering: draught, heating, etc. may all provoke faulty switching! - detector is too sensitive, reduce the detec-tion range sensitivity (by remote control or manually) or cover disturbing segments on the lens by adhesive tape. - check distances to lamps (heat reflection or direct light influence) - connect RC element in parallel to transformers, relais, electric ballast light flashes periodically / detector doesn t reach proper working condition: triggers or blocks at mains voltage peaks: light turns off even if motion is detected: turns the light on during daytime: - non-compensated fluorescent lamps need an RC element or compensation condenser installed. - install a Varistor between phase (L) and neutral (N) wires - increase the TIME value (to maximum if needed). - twilight adjustment set too high (set to a lower value). Respect 1 min. start-up! - detector is installed in the shade - consider changing the location of detector After mains connection: the detector takes approx. 1 min. to reach a stable working condition! 9

10 Technical data Nominal power: 230V ± 10 % / 50Hz Switching power: 2000W / 8.7A max. (cos φ = 1) 1000VA / 4.35A max. inductive (cos φ = 0,5) potential-free relay Time adjustment: short impulse approx. 1 sec. (with 20 or 60 sec. break) approx. 10 sec. to 20 min. Twilight switch: 5 to 2000 lux or lux memory (via remote ctrl) IR remote control: AUTO / ON / OFF (4 to 6 m range) pet tolerance function ON/OFF Detector head: rotatable ± 90 vertical; ± 90 horizontal Detection area: 300 /240 /120 horizontal creep zone protection* Detection range: 16 m max. frontal, 16 m max. lateral, Ø 4 m creep zone protection Rec. install. height: 2 to 5 m* (2.5 m recommended) Dimensions: 148 x 105 x 85 mm Temperature range: -20 to +50 C IP protection: IP 54, class II * creep zone protection or pet tolerance function selectable. Tilting the detector head (long range zone pointing towards the ground) impairs pet tolerance function. Electronic Control Induction in long installation wires (if several detectors connected in parallel) may generate a considerable capacitive current on the switched phase. For electric loads using only a small control current, such as staircase timer switches, this may lead to permanent switching or general malfunctions. In order to minimise the capacitive current, an RC element may be connected in parallel to the load. Alternatively, a contactor, which is more tolerant to capacitive currents, may be installed before the load. We recommend a maximum of four detectors connected in parallel. Do not dispose of electrical appliances in your waste bin, use the collecting point of your municipality, or return the old device to your dealer. 10

1. Basic safety information 3 2. Proper use 3

1. Basic safety information 3 2. Proper use 3 310481 01 EN Motion detectors theluxa P220 WH 1010605 theluxa P220 BK 1010606 theluxa P300 WH 1010610 theluxa P300 BK 1010611 1. Basic safety information 3 2. Proper use 3 Disposal 3 3. Description 4 4.

More information

IP 55 (category II) IP 54 (category II) 4. Connection. 1. Basic safety information. 2. Proper use. 5. Installation. 3. Description.

IP 55 (category II) IP 54 (category II) 4. Connection. 1. Basic safety information. 2. Proper use. 5. Installation. 3. Description. EN Motion detectors theluxa P0 WH 0 theluxa P0 BK 0 theluxa P00 WH theluxa P00 BK. Basic safety information WARNING anger of death through electric shock or fire! ¾Installation should only be carried out

More information

1 Safety instructions. 2 Device components. Observer 220. Art.-No.: W 220 WW. Operationsmanual

1 Safety instructions. 2 Device components. Observer 220. Art.-No.: W 220 WW. Operationsmanual Observer 220 Art.-No.: W 220 WW Operationsmanual 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause

More information

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector 307021 3. Proper use EN Motion detector themova P360-100 UP WH 1030600 themova P360-100 UP GR 1030601 The motion detector is intended for interior. The motion detector is eclusively intended for the use

More information

1. Basic safety information 3 2. Proper use 3

1. Basic safety information 3 2. Proper use 3 307146 03 EN Presence detector thepiccola P360-100 DE WH 2090200 1. Basic safety information 3 2. Proper use 3 Disposal 3 3. Device description 4 4. Installation and connection 4 Installing the presence

More information

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42 Presence detector ECO-IR 360C NT Art. Nr. 202 0 400 D F GB E I NL S N FIN DK Bedienungsanleitung 2 Notice d utilisation 22 Installation manual 42 Manual de instrucciones 62 Istruzioni per l uso 82 Gebruikershandleiding

More information

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector EN Motion detector themova S360-101 DE WH 1030565 themova S360-101 DE GR 1030566 themova S360-101 AP WH 1030555 themova S360-101 AP GR 1030556 1. Product characteristics 307067 Passive infra-red motion

More information

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6 307214 1103107701 EN Presence detector theronda S360-101 DE WH 2080565 theronda S360-101 DE GR 2080566 theronda S360-101 AP WH 2080555 theronda S360-101 AP GR 2080556 1. Product characteristics 4 2. Safety

More information

Eco-sensors - PIR. Catalogue number(s): / / Use. 1. Use Technical characteristics (continued)

Eco-sensors - PIR. Catalogue number(s): / / Use. 1. Use Technical characteristics (continued) Page. Use..................................... 2. Technical characteristics................. 3. Dimensions.............................2 4. Connection.............................2 5. Removal................................3

More information

PräsenzLight PräsenzLight PräsenzLight A.. PräsenzLight A..

PräsenzLight PräsenzLight PräsenzLight A.. PräsenzLight A.. Presence detector PräsenzLight 180.. PräsenzLight 360.. PräsenzLight 180-100A.. PräsenzLight 360-100A.. D F GB E I NL S N FIN DK Bedienungsanleitung 2 Notice d utilisation 26 Installation manual 50 Manual

More information

Detector switch - Dual Tech

Detector switch - Dual Tech Page 1. Use.................................... 1 2. Technical characteristics................1 3. Dimensions............................ 2 4. Connection........................... 2 5. Installation...........................

More information

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series Installation Instructions Contents 1.0 Product Range...3 2.0 Principle of Operation...3 3.0 Field of View...3 4.0 System Components

More information

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2 II112918-SL Installation Guide VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2 TECHNICAL DATA Rated voltage: 220V-240V~ 50/60Hz Load: Load 1( /T1) for Lighting Incandescent: Max.

More information

IP65 High Bay Dual Sense Sensor

IP65 High Bay Dual Sense Sensor IP65 High Bay Dual Sense Sensor TM and, Daylight Harvest with Remote Control Technical Data Input Characteristics Sensor Data Model No. Model No. Mains voltage 220-240VAC 50/60Hz Sensor principle High

More information

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm). Flush Mount PIR Motion Sensor PIR 1-10V Dimming with Remote Control Mechanical Structure 70mm 64.7 4 56 68.1 73.3 Ø85 3 (1) Sensor inset (2) Lens pluggable Infrared receiver 1 Photocell LED indicator (3)

More information

compact office 24V compact office 24V Lux

compact office 24V compact office 24V Lux Presence detector compact office 24V compact office 24V Lux Art. Nr. 201 4 000 Art. Nr. 201 4 001 D F GB E I NL S N FIN DK Bedienungsanleitung 2 Notice d utilisation 22 Installation manual 42 Manual de

More information

IP65 High Bay Dual Sense Sensor

IP65 High Bay Dual Sense Sensor IP65 High Bay Dual Sense Sensor TM and, 1-10V Dimming with Remote Control Technical Data Input Characteristics Sensor Data Model No. Model No. Mains voltage 220-240VAC 50/60Hz Sensor principle High Frequency

More information

compact office 24V compact office 24V Lux

compact office 24V compact office 24V Lux Presence detector compact office 24V compact office 24V Lux Art. Nr. 201 4 000 Art. Nr. 201 4 001 D F GB E I NL S N FIN DK Bedienungsanleitung 2 Notice d utilisation 21 Installation manual 40 Manual de

More information

1. Basic safety information 3 2. Proper use 3

1. Basic safety information 3 2. Proper use 3 307274 EN Motion detector theluxa R180 WH 1010200 theluxa R180 BK 1010201 1. Basic safety information 3 2. Proper use 3 Disposal 3 3. Connection 4 4. Installation 5 Installation instructions 5 5. Description

More information

High Frequency Sensor

High Frequency Sensor Model: HF1 Installation & Operating Instructions High Frequency Sensor 1. Specifications: 1. Power: AC 220 ~ 240V 50MHz. 2. Sensor Technology: 5.8GHz High Frequency. 3. Switching capacity: 1000W Incandescent

More information

System 2000 System 2000 automatic control switch Safety instructions. 2 Device components

System 2000 System 2000 automatic control switch Safety instructions. 2 Device components pure white Order-No. : 2270 02 colour aluminium Order-No. : 2270 04 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure

More information

Installation Instructions

Installation Instructions Specifications PW-100 PW-200 PW-100/PW-100-347/PW-200/PW-200-347 v3 Passive Infrared Wall Switch Occupancy Sensor PW-100-347 PW-200-347 Voltages: PW-100 & PW-200................ 120/277VAC, 50/60Hz PW-100-347

More information

Detailed operating instructions

Detailed operating instructions MA00613903 Detailed operating instructions MD 360/8 Basic EB10430404 MD 360i/8 Basic EB10430428 MD 360/24 Basic EB10430848 MD 360i/24 Basic EB10430862 MD 360/8 Basic SMB EB10430497 MD 360i/8 Basic SMB

More information

PresenceLight 180 PresenceLight 360

PresenceLight 180 PresenceLight 360 Presence detector PresenceLight 180 PresenceLight 360 Art. Nr. 200 0 050 Art. Nr. 200 0 000 D F GB E I NL Bedienungsanleitung 2 Notice d utilisation 22 Installation manual 42 Manual de instrucciones 62

More information

Integrated PIR detectors

Integrated PIR detectors EBMINT - Product Guide Integrated PIR detectors Overview The EBMINT series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor ILD Compact control module with ambient light sensor and motion sensor Compact dimensions for luminaire installation For up to 10 DSI or DALI devices (max. 5 per output channel) 2 DALI/DSI output channels

More information

2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS

2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS 2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS SLB2000 PIR LIGHT CONTROLLER - BLACK WEATHERPROOF IP44 PIR SWITCHING 2000w MAXIMUM MANUAL ON/OFF OVERRIDE TIME

More information

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver Product Guide EBDHS-AD-LT30 Ceiling PIR HS presence detector 1-10V, low temperature Overview The EBDHS-AD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads with

More information

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor Product description Compact dimensions for luminaire installation For up to 10 DSI or LI devices (max. 5 per output channel)

More information

False Ceiling HF Sensors

False Ceiling HF Sensors False Ceiling HF Sensors HC009S/EXT HC018V/EXT HC019V/EXT Applications Ideally suited to retrofit projects where the luminaire is too small to accomodate the sensor internally, this motion sensor can be

More information

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1 Compact dimensions for luminaire installation For up to 10 DSI or DALI devices (max. 5 per output channel) DALI/DSI output channels with adjustable negative offset from channel to channel 1 Ambient light

More information

Tri-level Control HF Sensor

Tri-level Control HF Sensor Daylight Monitoring TM Ambient daylight threshold Loop in Loop out Tri-level Control HF Sensor HC403VRC-KD Detached Version with Daylight Monitoring Applications Occupancy detector with tri-level dimming

More information

11,1 30. Ordering data

11,1 30. Ordering data ID Compact control module with ambient light sensor and motion sensor Compact dimensions for luminaire installation For up to 10 DSI or I ballasts I/DSI output channels with adjustable negative offset

More information

LUX Hardwired - Installation Notes

LUX Hardwired - Installation Notes Ness LUX wired PIR with Nightlight Quad element pyro sensor 15m x 15m wide angle coverage Look down Creep Zone Selectable Standard and Pet Aware modes Adjustable sensor mask for No Creep and Pet modes

More information

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR 8. SPECIFICATION LOAD 6 Amps fluorescent and incandescent lighting. 3 Amps compact fluorescent lighting. 3 Amps low energy lighting. 3 Amps low voltage lighting (switch primary of transformer). Switch

More information

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features Product Guide MWS5 Miniature Microwave Presence Detector (standalone) Overview The MWS5 series of miniature microwave presence detectors provide automatic control of lighting loads with optional manual

More information

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Ceiling PIR HS presence detector. Product Guide. Overview. Features Product Guide 796-2047 Ceiling PIR HS presence detector Overview The 796-2047 (passive infrared) presence detector provides automatic control of lighting loads with optional manual control. This is a high

More information

Movement-based energy control

Movement-based energy control 04 Movement-based energy control 94 International catalogue 2015 4.1 Microwave-based movement sensors 4.2 PIR-based movement sensors 4.2.1 Ceiling-mount 4.2.2 Wall-mount 4.3 Twilight switches 4.4 LED lights

More information

12W Round LED Wall/Ceiling Light with Microwave Sensor

12W Round LED Wall/Ceiling Light with Microwave Sensor 12W Round LED Wall/Ceiling Light with Microwave Sensor Model: LEDSR12WHMS Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further

More information

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PPAD-C-HB-DALI-230V Product Guide Ceiling PIR HS presence detector DALI / DSI dimming Overview The PPAD-C-HB-DALI-230V PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

LUXOMAT PD4/M PD4/S. SM Surface mount. FC Ceiling mount. FM Flush mount

LUXOMAT PD4/M PD4/S. SM Surface mount. FC Ceiling mount. FM Flush mount Operating and mounting instruction occupancy detector PD4/Master and Slave less effort, in particular in situations where there is a large number of occupancy detectors in use, such as, for example, in

More information

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER TOCR0 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER SAFETY PRECAUTIONS Be sure to switch off power source before installing. Make sure that the power wiring comes from circuit with an external 16A miniature

More information

60W Multi PIR Bulkhead

60W Multi PIR Bulkhead 60W Multi PIR Bulkhead Model: MLB98 Black Installation & Operating Instructions 1. General information: The unit utilises passive infrared technology to detect heat radiation of moving human bodies. Upon

More information

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR 307079 EN Motion detector themova P360 KNX UP WH 1039600 themova P360 KNX UP GR 1039601 1. Product characteristics 4 2. Safety 5 3. Proper use 6 4. Function 6 5. Detection area 10 6. Installation 13 7.

More information

, ,

, , 796-2028, 796-2021, 796-2025 Batten mount PIR detectors Overview This series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver EBDSPIR-HB-DD Product Guide High bay PIR presence detector DALI / DSI dimming Overview The EBDSPIR-HB-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional

More information

2. Safety. 1. Product characteristics. 3. Proper use. 4. Operation. Function description. Presence detector

2. Safety. 1. Product characteristics. 3. Proper use. 4. Operation. Function description. Presence detector EN Presence detector theprema S360-100 E UP WH 2070600 theprema S360-100 E UP GR 2070601 1. Product characteristics 307184 1103087901 Passive infrared presence detector for ceiling installation Square

More information

FR-A180 FR-A360. Occupancy detector. Use

FR-A180 FR-A360. Occupancy detector. Use 5 488 Occupancy detector with daylight sensor Occupancy detector with integral daylight sensor for demand-based control of HVAC systems and lighting. Adjustable switch-on and switch-off delay Adjustable

More information

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor. Product Guide EBDSM-DD Ceiling PIR presence detector DALI / DSI dimming Overview The EBDSM-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

Connections, displays and operating elements C D E G H. Installing the control unit

Connections, displays and operating elements C D E G H. Installing the control unit 1 2 3 GB Control unit 0-10 V REG-K/3-gang with manual mode Operating instructions Art. no. MTN646991 ¼ DANGER Risk of fatal injury from electrical current. All work on the device should only be carried

More information

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features EBDHS-DD-LT30 Product Guide Ceiling PIR HS presence detector DALI / DSI, low temperature Overview The EBDHS-DD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

ARGUS movement detectors

ARGUS movement detectors ARGUS movement detectors Working principle Almost all movement detectors, including the ARGUS, function according to the principle of passive infrared technology. They measure and compare the infrared

More information

18W Round LED Wall/Ceiling Light with Microwave Sensor

18W Round LED Wall/Ceiling Light with Microwave Sensor 18W Round LED Wall/Ceiling Light with Microwave Sensor Model: LEDMR18WHMS Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further

More information

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MPAD-C-DALI-230V Product Guide Ceiling microwave presence detector DALI / DSI Overview The MPAD-C-DALI-230V microwave presence detector provides automatic control of lighting loads with optional manual

More information

2. Safety. 1. Product characteristics. 3. Proper use. 4. Operation. Function description. Presence detector

2. Safety. 1. Product characteristics. 3. Proper use. 4. Operation. Function description. Presence detector EN Presence detector theprema P360-101 E UP WH 2070105 theprema P360-101 E UP GR 2070106 1. Product characteristics 307175 1103087101 Passive infrared presence detector for ceiling installation Square

More information

PRODUCT INFORMATION. Uses tough, high quality PC diffuser, resistant to fracture and to ultraviolet light to limit discolouring.

PRODUCT INFORMATION. Uses tough, high quality PC diffuser, resistant to fracture and to ultraviolet light to limit discolouring. Ø297mm Packing list in Ceiling Mount Lamp LEDS 96PCS Φ6 Wall plug 3x30 Screw Φ3 Sealing ring 4x12 Y type Stainless Screw Quantity 1X 4X 4X 3X 3X PRODUCT INFORMATION 98.5mm Ideal for energy saving this

More information

Detailed operating instructions

Detailed operating instructions MA00744002 Detailed operating instructions MD-FLAT 360i/8 RW EP10427886 MD-FLAT 360i/8 SW EP10427893 MD-FLAT 360i/8 RB EP10428074 MD-FLAT 360i/8 SB EP10428081 MD-FLAT-E 360i/8 RW GST EP10427862 MD-FLAT-E

More information

LUXOMAT Application examples for electricians and planners

LUXOMAT Application examples for electricians and planners LUXOMAT Application examples for electricians and planners Plan with B.E.G. comfortably and certainly Along with a great number of useful practical tips, in this chapter you will also find many application

More information

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver Product Guide EBDSPIR-HB-AD High bay PIR presence detector 1-10V dimming Overview The EBDSPIR-HB-AD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

LIGHT SYSTEMS CATALOG

LIGHT SYSTEMS CATALOG LIGHT SYSTEMS CATALOG JANUARY 2012 Motion detectors Twilight switches Sensor lights House number lights LED lights Ready-for-use products Rope light systems MOTION DETECTORS Motion detector 360 /180 LBS

More information

LED Compatible Daylight Harvesting and Motion Sensor System

LED Compatible Daylight Harvesting and Motion Sensor System MADE IN GERMANY BY OUR FRIENDS AT EPV DH1 Technical Data MAX. MOUNTING HEIGHT AMBIENT TEMP. CURRENT CONSUMPTION 5m 0 50 C (Indoor) max. 15mA at 24V SWITCHING CAPACITY Occupancy Signal: Max. Dimming Status

More information

GREEN LEAF PROGRAMMABLE THERMOSTAT FOR ELECTRICAL FLOOR HEATING INSTALLATION INSTRUCTIONS. EN-RaychemGreenLeaf-IM-EU0209 THERMAL BUILDING SOLUTIONS

GREEN LEAF PROGRAMMABLE THERMOSTAT FOR ELECTRICAL FLOOR HEATING INSTALLATION INSTRUCTIONS. EN-RaychemGreenLeaf-IM-EU0209 THERMAL BUILDING SOLUTIONS GREEN LEAF PROGRAMMABLE THERMOSTAT FOR ELECTRICAL FLOOR HEATING INSTALLATION INSTRUCTIONS pentairthermal.com/manuals/ THERMAL BUILDING SOLUTIONS EN-RaychemGreenLeaf-IM-EU0209 Rev2 CONTENTS 1. DESCRIPTION...3

More information

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide EBMPIR-MB Batten mount PIR detectors Overview The EBMPIR-MB series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual

More information

System 2000 System 2000 presence detector Comfort top unit. 1 Safety instructions. 2 Device components

System 2000 System 2000 presence detector Comfort top unit. 1 Safety instructions. 2 Device components pure white Order-No. : 0317 02 colour aluminium Order-No. : 0317 04 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure

More information

Data sheet. Function description. Benefits

Data sheet. Function description. Benefits uminaire-integrated modules ENOTEC modular system 110046819 Control CD I 110046818 Control CD CO1 110046814 ensor ED HF1 110046813 ensor ED HF2 110046816 ensor ED PIR Function description The new ENOTEC

More information

Model: MLSA360N. Installation & Operating Instructions. 360º Night Eye PIR Light Controller

Model: MLSA360N. Installation & Operating Instructions. 360º Night Eye PIR Light Controller Model: MLSA360N Installation & Operating Instructions 360º Night Eye PIR Light Controller Motion Sensor Detection Perspective View 5 metre 1 Ceiling Mount Position 0º Sensor Tilt Up 3º 3º 5 metre Sensor

More information

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. Product Guide LPCMPIRDSI Ceiling PIR presence detector DALI / DSI dimming Overview The LPCMPIRDSI PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

1 Safety instructions. 2 Device components. Light Management Universal automatic switch m. Art.-No.: AS Operating instructions

1 Safety instructions. 2 Device components. Light Management Universal automatic switch m. Art.-No.: AS Operating instructions Art.-No.: AS..1280-1.. Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause

More information

5W LED Energy Saver PIR Bulkhead

5W LED Energy Saver PIR Bulkhead 5W LED Energy Saver PIR Bulkhead Model: LED88PIR Black Installation & Operating Instructions 1. General information: The unit utilises passive infrared technology to detect heat radiation of moving human

More information

SECURITY LIGHT MODEL NO: CL6PIR OPERATION INSTRUCTIONS PART NO: GC0215

SECURITY LIGHT MODEL NO: CL6PIR OPERATION INSTRUCTIONS PART NO: GC0215 SECURITY LIGHT MODEL NO: CL6PIR PART NO: 4003535 OPERATION INSTRUCTIONS GC0215 INTRODUCTION Thank you for purchasing this CLARKE Security Light with motion sensor. The motion sensor is a small electronic

More information

Microwave Sensor. Basic Microwave Sensor. Energy Saving Motion Sensor. Introduction Features Technical Specification. 3 Dimensions

Microwave Sensor. Basic Microwave Sensor. Energy Saving Motion Sensor. Introduction Features Technical Specification. 3 Dimensions Energy Saving Motion Sensor Introduction Features Sensor detection pattern 2 3 Dimensions Function Guidelines Installation and Wiring Wiring diagrams Set up guide About One-LUX Get in touch 4 5 6 Introduction

More information

Movement controller comfort, Flush-mounted (Up) xx, xx

Movement controller comfort, Flush-mounted (Up) xx, xx Order no.: 752615xx 752616xx The instabus movement controller comfort is designed for internal use and is pushed onto a flushmounted bus coupling unit (BCU). It reacts to heat movements triggered by persons,

More information

LPCMPIRM65 & LPCMPIRDSI65

LPCMPIRM65 & LPCMPIRDSI65 Product Guide LPCMPIRM65 & LPCMPIRDSI65 Luminaire high mount PIR detectors Overview The LPCMPIR PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

30W LED PIR FLOODLIGHT. Model: LEDX30PIRB Model: LEDX30PIRWH

30W LED PIR FLOODLIGHT. Model: LEDX30PIRB Model: LEDX30PIRWH 30W LED PIR FLOODLIGHT Model: LEDX30PIRB Model: LEDX30PIRWH 1. Designated Use LEDX30PIR is an outdoor motion detector for automatic LED lighting control. Mainly for wall installation. Simple plug in wall

More information

EBMHS (standard & slim-line PSU)

EBMHS (standard & slim-line PSU) Product Guide EBMHS (standard & slim-line PSU) Miniature HS PIR Presence Detector (luminaire fitting) Overview The EBMHS series of miniature PIR (passive infrared) presence detectors provide automatic

More information

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit A Honeywell Company Gas Burner Safety Control For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit Possible flame detectors: - Ionisation probe - Infrared flicker

More information

360º Surface Mount Ceiling PIR Light Controller

360º Surface Mount Ceiling PIR Light Controller 360º Surface Mount Ceiling PIR Light Controller Model: PDRS1500 Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further reference

More information

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide PIR/INT & PIR/INT-D Batten mount PIR detectors Overview The PIR/INT & PIR/INT-D miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional

More information

Presence detector Komfort attachment Installation Instructions

Presence detector Komfort attachment Installation Instructions Presence detector Standard attachment Order no.: 0304 0x Order no.: 0319 0x System information This unit is a product of the Instabus-EIB-System and corresponds to the EIBA Guidelines. Detailed technical

More information

Compact Movement Activated Sensor Installation Instructions

Compact Movement Activated Sensor Installation Instructions MAL540 Instructs. 12/7/06 3:43 PM Page 3 Compact Movement Activated Sensor Installation Instructions MAL540 series 2 Where to fit your Security Sensor To achieve best results for outside use the Arlec

More information

360 Ceiling PIR Light Controller

360 Ceiling PIR Light Controller 360 Ceiling PIR Light Controller Model: SLFM360L Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further reference and maintenance.

More information

SCS motion sensors Surface/wall mounting - PIR

SCS motion sensors Surface/wall mounting - PIR IP55 Page 1. Use.....................................1 2. Technical characteristics................1 3. Dimensions............................1 4. Connection.............................1 5. Removal................................2

More information

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use! Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 74363 Güglingen Telefon +49 7135-102-0 Service +49 7135-102-211 Telefax +49 7135-102-147 info@afriso.de

More information

360 Surface Mount Ceiling PIR Light Controller

360 Surface Mount Ceiling PIR Light Controller 360 Surface Mount Ceiling PIR Light Controller Model: SLW360L Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further reference

More information

A watchdog that never sleeps.

A watchdog that never sleeps. A watchdog that never sleeps. HE WELCOMES VISITORS AND DETERS BURGLARS. HE SEES EVERYTHING AND CAN TURN NIGHT INTO DAY, IF NEEDED. THE NEW GENERATION OF BUSCH-WATCHDOG STANDS FOR STATE-OF-THE-ART, COMPREHENSIVE

More information

The Power To Supply... All Your Electrical Products

The Power To Supply... All Your Electrical Products ENERGY EFFICIENT RETROFIT SOLUTIONS The Power To Supply... All Your Electrical Products www.cef.co.uk All products are subject to availability and are correct at the time of print. Errors and omissions

More information

Product and Applications Description

Product and Applications Description Product and Applications Description The presence detector with a sensing range of 360 allows the automatic execution of control functions in the electrical system by detecting movements. For example,

More information

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS DETECTOR TRANSMITTER Cat No. TLTX2000B INSTALLATION & OPERATING INSTRUCTIONS 1 Introduction The TLTX2000B Controller Transmitter is part of the Timeguard range of PIR products which communicate by radio

More information

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC Product Guide EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC Ceiling PIR presence/absence detector Overview The EBDSPIR-PRM-VFC PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

GI1DPC/B User Guide. Mains tungsten GLS filament or halogen lamp Min 60W Max 300W. Linear fluorescent

GI1DPC/B User Guide. Mains tungsten GLS filament or halogen lamp Min 60W Max 300W. Linear fluorescent GI1DPC/B User Guide Single gang PIR Dimmer Replaces a standard light switch or dimmer Turns off automatically Turns on automatically Security mode Night light mode* Scene setting and soft on/off* * only

More information

Tri-level Control HF Sensor

Tri-level Control HF Sensor Tri-level Control HF Sensor Standard Version Applications Occupancy detector with tri-level control suitable for indoor use. Suitable for building into the fixture: Office / Commercial Lighting Use for

More information

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features Product Guide VITMR-EBDSPIR-PRM PIR Presence/Absence Detector IR with Ceiling Rose Overview The VITMR-EBDSPIR-PRM PIR (passive infrared) presence detector provides automatic control of lighting loads.

More information

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47) DIESEL ENGINE CONTROL UNIT DCU 205 - USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) 64 84 52 00 Fax: (+47) 64 84 52 12 office@auto-maskin.no - 1 - TABLE OF CONTENTS 1. INTRODUCTION TO THE DCU 205...4

More information

INDUCTION COOKER MODEL: EIC-G1810(BK) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference.

INDUCTION COOKER MODEL: EIC-G1810(BK) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference. INDUCTION COOKER MODEL: EIC-G1810(BK) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference. Record model number and serial number of the set. See the

More information

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English Rectifier RC-series Manual RC-series English Manual Wall and 19 English Presentation The RC-series is a rectifier for either directly powering the load or for use together with batteries. It is designed

More information

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols. ACTIV8 ONE OFF USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR 1 Description Cover 2 nd Radar Antenna Radar motion sensor Push-Buttons IR-Presence sensor Radar Antenna clip IR-Prism

More information

B.E.G. LUXOMAT. Find the right detector.

B.E.G. LUXOMAT. Find the right detector. B.E.G. LUXOMAT Find the right detector www.beg-luxomat.com B.E.G. B.E.G. SMARTPHONE APP The new B.E.G. remote control app 92726 Rapid programming by smartphone The B.E.G. remote control app is the easiest

More information

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor TECHNICAL SPECIFICATIONS PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor Basic Features Line voltage version: 120-277VAC, 60Hz Low voltage version: 24VDC, requires separate class 2 power supply PIR sensor

More information

UP 258E11 OPTISENS OFFICE

UP 258E11 OPTISENS OFFICE Product and functional description The UP 258E11 is a presence/motion detector with integrated 2-point light control. The UP 258E11 device communicates via KNX/EIB with actuators or other KNX devices.

More information