1 EliteA Analog Addressable Fire Control Panels (2 or 4 Loops) (Apollo Protocol) VF1460 (2 Loops) VF1480 (4 Loops) Standard Features UL 864 9th Edition listed MultiLoop 2 Analog Addressable Loops Field upgradable to primary points per loop Powerful, network wide cause and effects (500 total). Fully user programmable by point or zone. 800 points per panel when using devices with subpoints Up to 10,000 ft. wiring length on SLC loop 64 Panels on a network Programmable through a PC connection to the panel, or through keypad Programmable relays 5 Supervised Powered Outputs 3 Programmable Notification Appliance Circuits: 4 Power per NAC: 1.6 Amps Max Programmable outputs on SLC loop Programmable Function button on front display Fire Drill button on front display Day and night sensitivity settings (user programmable) Power Supply: 5.25 Amp, regulated & integrated LCD Display: 8x40 Zonal Mode: Annunciation by zone w/o individual relationships Panel Ring Modes: Common, Zonal, Stage 2 NAC Outputs programmable as Continuous, March, Temporal Program Cause and Effects AND, OR, or Any Two (Cross Zone) Battery size: Up to 17 Ah in standard enclosure; up to 52 Ah with external cabinet Access levels: 3 Access key switch: Yes Recognized for use in High Rise One man walk test Fire Test Mode Available with semi flush trim ring Available in Red or Gray Product Overview The VF1460 and VF1480 analog addressable FACP with networked releasing, supports 2 or 4 SLC loops for a total of 500 primary points or 800 points using subpoints. SLC loop communications uses standard twisted pair cabling, shielded cable is not necessary. The panel may be configured with various communication cards; Communications options support remote programming, central station monitoring, Virtual Panel, and networking. The Panel can be configured as a stand alone panel with just a few devices for a small building, it can also operate as the building system and can be part of a network with a total of 64 nodes serving a multiple building campus or a very large facility. Auto Learn capability provides a convenient method to troubleshoot new installations before final programming is loaded.

2 Added Features: Elite with enet (VF1465/VF1485) Network uses standard RS485 cabling Up to 2,000 ft. between adjacent panels 115 Kbps constant network speed Secure, fault tolerant communication Up to 64 nodes Elite with DACT (VF1464/VF1484) Dual line digital communicator and modem Contact ID and SIA reporting UL 864 9th edition listed Zone or point reporting Backup and duplicate reporting Virtual Panel Capability via Ethernet Also available: 2 loop expansion board VF1053 Trim ring VF1070 Technical Specifications Primary AC: 2 Amps 60hz (Optional 240 VAC 50hz) Output DC: 4 Amps Power Supply: 5.25 Amp regulated and integrated Charger Current: 1.25 Amps max. Dimensions: 14.5 W x 24 H x 5 D Weight: 25 lbs. (without batteries) Color: Red (optional gray) Display: 8 line x 40 character LCD (320 characters total) Zones: 500 Zones per network SLC loops: 2 or 4 (class A or B) Devices per loop: 126 sensors & modules (800 addresses + subaddresses max. per panel) NAC Outputs: (4) VDC (class B) Relay Outputs: (5) Form C 1 30VDC Voltage Outputs: (3) 24VDC, reverse polarity supervised Aux. Power: 24VDC Aux. Inputs: (3) digital pull downs Current Consumption VF1460 VF1480 VF1465 VF ma Standby 650 ma Alarm 455 ma Standby 765 ma Alarm 430 ma Standby 745 ma Alarm 430 ma Standby 730 ma Alarm

3 Elite RSA Analog Addressable Fire Control Panels (1 or 2 Loops) Apollo Protocol VF0850 (1 Loop) VF0860 (2 Loops) Standard Features One full SLC circuit expandable to two 3 programmable relays 5.25A power supply Large graphic display Real time clock Compatible with ematri graphics annunciator Powerful, network wide cause and effects (500 total). Fully user programmable by point or zone. Can be networked with additional RS and/ or Elite control panels Compatible with eview Annunciator Programmable through a PC connection to the panel Same look and feel as Elite range Stores 1000 last events in history log Model ranges include with or without a DualLine internal DACT Product Overview Elite RS is a versatile range of open protocol fire alarm control panels compatible with existing Elite fire alarm panel technology. Available with one or two detection loops capable of hosting up to 600 devices. Elite RS uses leading edge microprocessor based electronics to provide a flexible control system with high reliability and integrity. Suitable for all small to medium sized fire detection systems,elite RS control panels can be expanded and networked to become part of much larger systems if the need arises, therefore providing a future proof solution for any installation. With its large graphical display and ergonomic button and indicator layout, the Elite RS control panel is simple and straightforward to understand for installers, commissioning engineers and end users alike. Compact, stylish enclosure Available in Red or Gray 2 Programmable NAC circuits with internal synchronization support.

4 Added Features: Elite RSA with Internal Modem/DACT (VF0856/VF0866) Dual line digital communicator and modem Central Station reporting; SIA and Contact ID Onboard loop start terminal connections for both primary and secondary Telco lines Elite RSA with Ether/DACT (VF0854/VF0864) Dual line digital communicator and modem Central Station reporting; SIA and Contact ID Phone line jacks RJ11 (two) Modem speed: 33.6 Kbps for program downloading Virtual panel capability via Ethernet Elite RSA with Network Interface Card (VF0852/VF0862) Network uses standard Cat 5 cabling Up to 2,000 ft. between adjacent panels 115 Kbps constant network speed TCP and UPD communications through VESNet Total network delay less than 3 sec. with 127 panels Network jacks RJ45 (VESNet and Ethernet) Mapped Network; Display messages for Any or All nodes Elite RSA with Media Gateway (VF0851/VF0861) All the features of the Ether/DACT and NIC plus: Enables network programming with direct TCP/IP access to each panel Access point for network communications Technical Specifications Construction: 16AWG sheet steel Dimensions: 14.5 W x 18.9 H x 4.25 D Weight (without batteries): 20lb Finish (lid & box): RAL3002 (Red) or BS 00 A 05 (Gray) Finish (product labels): BS 00 A 05 (Gray) Mains voltage supply: 110 or 230V AC 50 or 60 Hz. (specify when ordering, default is 110V) Mains supply fuse: 1.6A 250V Power supply DC rating: 24V 5.25 Amps Aux 24V supply: Fused at 500 milliamps Battery (24 hour standby): 9Ah 12V (2 per panel) (nonnetworked) Fault contact rating: 30V DC 1 Amp Fire contact rating: 30V DC 1 Amp Alarm contact rating: 30V DC 1 Amp NAC output rating: 3.1V across both channels, 2.3V across any one Detection loop: 250 milliamp output Printer port: Serial RS232 Serial expansion port: Serial RS485 PC port: Serial RS232 Network connection: Optional network Cards allow the use of enet networking or VESnet networking NAC Synchronization: Internal Support NAC Protocols: System Sensor, Wheelock, Gentex, Amseco Also available: enet Networking Card VF loop expansion board VF1054 Trim ring VF1071

5 eview VF1172 Analog Addressable Serial Annunciator Red version Gray version Standard Features Available in Red or Gray Up to 15 annunciators can be connected to each Elite or Elite RS fire control panel Large liquid crystal display (240 x 64 pixels) High brightness LED indications Internal sounder Replicates all panel controls (Elite) Simple, twowire serial connection Small, Elite style enclosure Removable electronics for easy installation 24V DC powered Low power consumption Multi language options Connection supervised by Elite fire control panel Recess mounting using optional VF1173 kit Product Overview Designed and manufactured to the highest standards in a quality controlled environment the eview fire alarm annunciator provides a simple and convenient method of extending the controls and indications of the Elite fire alarm control panel to other locations. The large, graphic liquid crystal display and high brightness LED indicators duplicate the indications on the Elite fire alarm control panel at up to 15 additional locations via a simple, twowire serial data connection. The eview is powered by 24V DC (which can be via an additional 2 conductors from the control panel or local 24V DC listed supply). eview is housed in a small enclosure which is styled similarly to the Elite control panel and is ideal for installations where a large control panel would be detrimental to décor such as entrance halls. Up to 15 eview annunciators can be connected to each control panel on the Elite network making eview ideal where multiple points of indication and/or control are required such as nurses stations or shop units.

6 elan or Elite series control panel eview #1 eview #15 Comms Comms In Comms Out 24V In 24V Out Comms In Comms Out 24V In 24V Out Aux 24V Technical Specifications Construction: 18AWG sheet steel Cable entry: 4 knockouts in back of box and 1 in left and right sides Dimensions: 10.4 W x 7.5 H x 1.6 D Weight: 3.5 lbs. Finish : RAL3002 (Red) or BS 00 A 05 (Gray) 24V supply: 21 to 30V DC Maximum ripple current: 200 millivolts Quiescent current of panel in mains fail: 0.03 Amps Serial data connection: 2 core RS485 (Up to 1200 metres total cable length) Maximum terminal capacity: 12AWG The VES trim ring allows the eview annunciator to easily be recess mounted. VES trim rings provides placement tabs that fold behind dry wall. Traditional screw mounting is available by 2 openings in each of the vertical frames. Conduit entry is not blocked by trim ring. Trim Ring Technical Specifications Part number: VF1173 Outter Dimensions: 11.3 W x 8.6 H x 1.3 D Inner Dimensions: 10.3 W x 7.4 Color: Available in Red (VF117310) or Gray (VF117340)

7 ematri Configurable Floor Plan Mimic Annunciator Standard Features Available in Red or Gray Up to 504 LED s can be controlled from any Elite panel Select up to 12 printed colors (not including background and building outline) Available in a range of standard enclosures to suit any applications Custom sized units can be made upon request Choice of Red, Green or Yellow LED s ematri can easily be upgraded on site with minimal cost and effort UL 864 9th edition listed Product Overview The ematri system uses flexible, optic light guides to illuminate areas on a floor plan, laid over a high resolution grid. This unique system dispenses completely with wiring and enables indicators to be moved, removed or added on site without the need for any wiring. All indicators can be configured to operate upon any event type and at point, zone or group level via the powerful and intuitive Loop Explorer configuration or ESP Discovery. ematri can be supplied with or without LEDs and controls. Optional LEDs indicate Power on, Fire, Trouble and Disablement and optional controls are for Alarm silence, Buzzer silence, Lamp test and Reset. Housed in attractive, slimline enclosures to match Elite fire alarm panels and with high quality, full color or floor plans, ematri provides a clear, geographical indication of fire alarm activation enabling speedy identification of the source of an alarm. View showing mimic mounted on inner door View showing LED grid View showing internal layout

8 Technical Specifications Quiescent current: See above Supply voltage: 21 to 30V DC Supply current: See above Terminal capacity: 22 AWG to 12 AWG solid or stranded wire Enclosure Size & mimic area: see Enclosure Size Options Construction: 16 gauge mild steel Finish: epoxy powder coat Mimic: 3mm Clear AntiGlare Acrylic Cabinet locks: CAT30 key Communications interface: RS485 Elite serial I/O bus protocol Maximum distance from control panel: 4000 feet using RS485 data cable IP rating: IP30 Operating temperature: 20F to 120F Number of indicators (standard models): AM2 size up to 40 LED s, AM3 size up to 72 LED s, AM4 size up to 88 LED s Enclosure Size Options (Available in Red or Gray) AM3 11 AM AM Wide x 12.2 High x 3.5 Deep Max. number of LED s = 40 Will house 1 x 8 Red LED driver PCB and 2 x 16 LED extension PCB s (Red, Green or Yellow) 14.5 Wide x 18.9 High x 4.25 Deep Max. number of LED s = 72 Will house 1 x 8 Red LED driver PCB and 4 x 16 LED extension PCB s (Red, Green or Yellow) 14.5 Wide x 24 High x 5 Deep Max. number of LED s = 88 Will house 1 x 8 Red LED driver PCB and 5 x 16 LED extension PCB s (Red, Green or Yellow)

9 enet VF Elite Networking Part No. VF Standard Features Up to 64 nodes High integrity protocol when wired Class A Fully secure against short or open circuit faults Simple 2wire loop connection Supports open ended networks for retrofit applications Network wide test and disablement functions Network wide cause and effect logic Flexible configuration options Panels configurable to act on network events or not as required Product Overview The flexibility of the Elite system can be further enhanced by connecting control panels and repeaters together using a high integrity network. A simple 2wire connection between each panel allows events to be transmitted to other parts of the system to provide indication or control on a system wide basis. Using the Loop Explorer configuration software, up to 64 nodes can be programmed to respond in a variety of ways to any system events as required. This flexibility extends the comprehensive cause and effect programming capability of Elite control panels to the entire network allowing actions, test modes or disablements to be started from any point. The fault tolerance of the network is such that any single open or short circuit fault will not result in any loss of information. Multiple faults are isolated and the network breaks into smaller networks which continue to work autonomously.

10 Two conductor loop wiring ensures network integrity by providing full isolation of faulty wiring segments. 2 Conductor Elite Control Panel Elite Control Panel 2 Conductor (Not fitted on Class B networks) 2 Conductor Flexible network configuration options using simple to follow PC configuration software Elite Control Panel Technical Specifications Protocol: RS485 Connection: Two wire loop Current Consumption: 40mA Integrity: Full isolation of faulty nodes or wiring segments Indicators: Data In and Data Out communications status Cable length: 3900ft to adjacent nodes (subject to cable type) (see technical manual) Cable type: Belden 9271, Belden 9860, FP200 Gold Compatible panels: Elite/ Elite RS (required for networking)

11 GUIDE VF Graphical PC User Interface for Fire Detection Systems Standard Features Choice of text, graphic, event list display when an event occurs Versatile event analysis Total history archive Easy to program Secure system Cost effective compared to other systems Simple to use Unlimited map linking & zoom capability Support for 100 s of graphics Display and control for multiple panels Event history explore and export to text or HTML documents Product Overview Elite fire control panels can send data to, and be controlled by, the Guide system providing a single point of control for all alarms. The powerful 32 bit program features a standard Windows look and feel and runs under Windows P, Vista or Windows 7. The system is highly configurable in terms of the style of presentation so that the end user can be presented with maps, text, photographs, audio or a combination of all as required. User profiles allow the system manager to control the options available to each individual system user. A comprehensive history logging and reporting system allows analysis of events and trends to be identified to reduce unwanted alarms. Easy to program and simple to use, Guide provides a cost effective solution for fire alarm management at many levels. Virtual Panel allows direct control Powerful Event log filtering

12 Technical Specifications Recommended Minimum Notes Processor Intel Pentium 1Ghz The faster the better, 2Ghz will provide future proofing Operating system Windows P/Vista Will operate under Windows 2000 Memory 256MB minimum The larger the better Hard disk 10GB minimum >20GB would be better Graphics 1024 x M colors The driver must allow this mode with large fonts. Separate Graphics card with 256MB graphics memory recommended Sound card Any PC sound card Loudspeaker Any PC speakers More convenient if built into PC Monitor Any that supports above graphics driver 17 inch minimum recommended, the larger the better. (1024 x 768) Pointing device Mouse essential Third button and wheels are supported. Touch screen option supported Printer Optional Any type Parallel port Optional Required if parallel printer to be used Serial ports One RS232 per network Isolated converter supplied for connection to fire alarm system CDROM drive Any Required for installation of software and updates Backup drive CD Writer To back up history Note: Guide will be operating 24 hours a day for many years. It may be desirable to include on site PC maintenance as part of the package. Ordering Codes Part number Description VF GUIDE software 1 node VF GUIDE software 24 nodes VF GUIDE software 58 nodes VF GUIDE software 916 nodes VF GUIDE software 1732 nodes VF GUIDE software 3364 nodes Note: Guide For use with Elite Panels. Dongle fitted Guide System RS485 Elite RS Control Panel Elite Control Panel Elite Control Panel

13 VF5600 Discovery Ionization Smoke Sensor SLC Devices Standard Features Overview Sectional view Ionization Smoke Detector Mode PreAlarm (%/ft) Ionization detector operating modes Alarm (%/ft) Second Alarm Delay No Yes No Yes No Compatible with Elite and Elite RS control panels 5 operating modes Drift compensation Address is set by Pert card and is stored in base User memory Alarm flag for fast alarm reporting Conventional false safe mode Polarity insensitive Fits 4 & 6 low profile base 6 audible base 4 wire relay base Note: Bases and cards are not included with detectors, please order separately. The VF5600 Discovery Ionization Smoke Detector has a molded white polycarbonate case with windresistant smoke inlets. Inside the case is a printed circuit board which has the ionization chamber mounted on one side and the signal processing and communications electronics on the other. The ionization chamber consists of a reference chamber contained inside a smoke chamber. The outer smoke chamber has inlet apertures fitted with insect resistant mesh. Operation The radioactive source holder and the smoke chamber form positive and negative electrodes respectively. An Americium 241 radioactive source mounted within the reference chamber irradiates the air in both chambers, producing positive and negative ions. A voltage across the electrodes produces an electric field. Ions are attracted to the Electrode of the opposite sign to their own charge; many recombine but a small electric current flows between the electrodes. At the junction between reference and smoke chambers, the sensing electrode converts variations in chamber current into voltage hanges. When smoke particles enter the ionization chamber, ions become attached to them with the result that the current flowing through the chamber decreases. This effect is greater in the chamber decreases. This effect is greater in the smoke chamber than in the reference chamber, and the imbalance causes the sensing electrode to become more positive. The analog voltage at the sensor electrode is converted to a digital format which is processed to provide on analog value or transmission to the control panel when the device is polled.

14 Operation continued The VF5600 Discovery Ionization Detector, like all Ionization detectors, has some sensitivity to air movement (wind). The extent to which the analog value will change depends on the wind speed and on the orientation of the detector relative to the wind direction. Relatively small changes in wind direction can cause significant changes in analog value. For wind speeds up to 200 ft/min the change in analog value will not exceed 5 counts. Continuous operation in wind speeds greater than 400 ft/min is not however recommended. It will not under any conditions increase the probability of false alarms. Ionization smoke detectors are supplied in individual packing with a red lid serving as a dust cover which can be left in place after fitting to prevent ingress of foreign material until commissioning of the system takes place. At this point, the covers must be removed. Engineering Specification The Ionization smoke sensor shall be VF5600, where indicated on the plans, with one of the several addressable mounting base options available. The ionization smoke detector shall include compensation for sensor drift as part of the internal signalprocessing algorithm. The ionization sensor head and twistlock mounting base shall be UL Listed and UL Listed as compatible with the Elite Addressable Fire Alarm Control Panels. The base shall permit free interchange of sensor heads without requiring any additional wiring or additional programming of the head or base. The smoke sensor shall contain an integral LED that shall latch in when the unit goes into alarm. RF suppression techniques shall be employed to minimize false alarms. The ionization smoke sensor shall have automatic conventional false safe mode if the detectors polling mechanism fails. Technical Specifications Stand current: 500μA Alarm current: LED Illuminated 3.4mA Radioactive isotope: Americium 241 Operating voltage: 1728 VDC Max. continuous operating temp: 140 F Min. continuous operating temp: 32 F Min. Operating temp: 4 F (no condensation/icing) Storage: 22 F to 176 F Detector weight: 3.68 oz Detector with base weight: 5.62 oz Dimensions: Diameter: 3.93, Height: 1.65, Height in base: 1.96 Ordering Codes Part number Description VF5600 Ionization Smoke Detector VF Mounting Base VF Low Profile Relay Base VF5633 Isolator Base VF EZ Fit Low Profile Base VF Sounder Base VF5650 Blank PERT Cards VF5651 Preaddressed PERT Cards

15 VF5601 Discovery Photoelectric Smoke Sensor SLC Devices Top view Photoelectric Smoke Detector Mode PreAlarm (%/ft) Alarm (%/ft) 30 Second Alarm Delay Standard Features Compatible with Elite and Elite RS control panels 5 operating modes Drift compensation Two status LEDs Address is set by Pert card and is stored in base User memory Alarm flag for fast alarm reporting Conventional false safe mode Polarity insensitive Note: Bases and cards are not included with detectors, please order separately. Overview The VF5601 Discovery Photoelectric detector uses the same outer case as the ionization smoke detector and is distinguished by the indicator LEDs which will flash when the detector is in standby state and steady red in alarm. The housing is white polycarbonate and will not fade. Terminals are nickel plated stainless steel. Operation Within the case is a printed circuit board which, on one side, has the lightproof chamber with integral gauze surrounding the optical measuring system and, on the other, the signal processing and communications electronics. An infrared light emitting diode is arranged at an obtuse angle to the photodiode. The photodiode has an integral daylightblocking filter. The IR LED emits a burst of light every second. In clear air the photodiode receives no light directly from the IR LED, because of the angular arrangement and the chamber Baffles. When smoke enters the chamber it scatters light from the emitter IR LED onto the photodiode in an amount related to the smoke characteristics and density. The photodiode signal is processed to provide an analog value for transmission when the detector is interrogated No Yes No Yes No Photoelectric detector operating modes

16 Engineering Specification The Photoelectric Smoke Sensor shall be VF5601, where indicated on the plans, with one of the several addressable mounting base options available. The Photoelectric Smoke detector shall include compensation for sensor drift as part of the internal signalprocessing algorithm. The Photoelectric Sensor head and twistlock mounting base shall be UL Listed and UL Listed as compatible with the Elite addressable fire alarm control panels. The base shall permit free interchange of sensor heads without requiring any additional wiring or additional programming of the head or base. The smoke sensor shall contain an integral LED that shall latch in when the unit goes into alarm. RF suppression techniques shall be employed to minimize false alarms. The Photoelectric Smoke Sensor shall have automatic conventional false safe mode if the detectors polling mechanism fails. Technical Specifications Stand current: 400μA Alarm current: 3.4mA Operating voltage: 1728 VDC Max. continuous operating temp: 140 F Min. continuous operating temp: 32 F Min. Operating temp: 4 F (no condensation/icing) Storage: 22 F to 176 F Detector weight: 3.68 oz Detector with base weight: 5.62 oz Dimensions: Diameter: 3.93, Height: 1.65, Height in base: 1.96 Ordering Codes Part number VF5601 VF5630 VF5632 VF5633 VF5636 VF5631 VF5650 VF5651 Description Photoelectric Smoke Detector 4 Mounting Base 6 Low Profile Relay Base Isolator Base 6 EZ Fit Low Profile Base 6 Sounder Base Blank PERT Cards Preaddressed PERT Cards

17 VF5602 Discovery Heat Detector SLC Devices Standard Features Overview Compatible with Elite and Elite RS control panels 5 operating modes Fits into addressable 4 bases or 6 EZ Fit bases Addressable sounder alarm base Address is set by Pert card and stored in base User memory The VF5602 Discovery Heat Detector has a common profile with the ionization and photo smoke detector, but has a low air flow resistance case made of self extinguishing white polycarbonate. The VF5602 Analog Addressable Thermal Sensors are designed to provide the highest effectiveness by utilizing the latest technology. The sensor is designed for operation with the Elite addressable fire alarm control panels. Alarm flag for fast alarm reporting Fixed point or rate of rise function Note: Bases and cards are not included with detectors, please order separately. Operation The VF5602 Heat Detector uses a single thermistor to sense the air temperature at the detector position. The thermistor is connected in a resistor network, which produces a voltage output dependent on the temperature. The design of the resistor network, together with processing algorithm in the microcontroller, gives an approximately linear characteristic from 50 F to 176 F. This linearised signal is further processed, depending on the response mode selected, and converted to an analog output. A detector may be given an R or S suffix. The R suffix indicated that the detector has been shown to have a rate of rise characteristic. Such a detector will still give a rapid response even when starting from an ambient temperature well below its typical application temperature. Mode PreAlarm (%/ft) N/A N/A N/A N/A N/A Heat Detector response modes Alarm ( o F) 135 o 150 o 150 o 200 o 200 o Fixed/ ROR Profile FT & ROR FT & ROR FT FT & ROR FT This type of detector is therefore suitable for areas such as unheated warehouses in which ambient temperature may be very low for long periods. The S suffix indicates that the detector will not respond below its minimum static response temperature even when exposed to high rates of rise of air temperature. This type is therefore suitable for areas such as kitchens and boiler rooms where large, rapid temperature changes are considered normal.

18 Engineering Specification The thermal sensor shall be VF5602, where indicated on the plans, with one of the several addressable mounting base options available. The combination sensor head and twistlock mounting base shall be UL listed and UL Listed as compatible with the Elite addressable fire alarm control panels. The base shall permit free interchange of sensor heads without requiring any additional wiring or additional programming of the head or base. The sensor shall contain an integral LED that shall latch in when the unit goes into alarm. Technical Specifications Alarm current: LED Illuminated 3.4mA Radioactive isotope: Americium 241 Operating voltage: 1728 VDC Max. continuous operating temp: 140 F Min. continuous operating temp: 32 F Min. Operating temp: 4 F (no condensation/icing) Storage: 22 F to 176 F Detector weight: 2.3 oz Detector with base weight: 3.5 oz Dimensions: Diameter: 3.94, Height: 1.65, Height in base: 1.96 Ordering Codes Part number VF5602 VF5630 VF5632 VF5633 VF5636 VF5631 VF5650 VF5651 Description Heat Detector 4 Mounting Base 6 Low Profile Relay Base Isolator Base 6 EZ Fit Low Profile Base 6 Sounder Base Blank PERT Cards Preaddressed PERT Cards Sectional view Heat Detector

19 VF5603 Discovery Multisensor Detector SLC Devices Standard Features Compatible with Elite and Elite RS control panels 5 operating modes Combines photo, smoke, and thermal sensor value for enhanced detection performance and false alarm reduction Address is set by Pert addressing and is stored in the sensor base Rate of rise heat signals Drift compensation Polarity insensitive Overview The VF5603 Discovery Multisensor Detector contains a photo smoke sensor and a thermistor temperature sensor whose outputs are combined to give the final analog value. The way in which the signals from the two sensor are combined depends on the response mode selected. The five modes provide response behavior which incorporated pure heat detection, pure smoke detection, and a combination of both. The multisensor is therefore useful over the widest range of applications. The outer smoke chamber has inlet apertures fitted with insect resistant mesh. Sectional view Multisensor Detector Mode PreAlarm (%/ft) No Response Alarm (%/ft) No Response Multisensor Detector operating modes Heat Classification 140 o ROR 140 o ROR 140 o ROR 140 o ROR 135 o FT & ROR Fits 4, 6, or 6 low profile bases 6 audible base 4 relay base Note: Bases and cards are not included with detectors, please order separately. 20 Second Alarm Delay Yes Yes Yes Yes No The Multisensor construction is similar to that of the photo detector but uses a different lid and optical moldings to accommodate the thermistor temperature sensor. The sectional view shows the arrangement of the optical chamber and the thermistor. Operation The signals form the optical smoke sensing element and the temperature sensor are independent, and represent the smoke level and the air temperature respectively in the vicinity of the detector. The detector s microcontroller processes the two signals according to the mode selected. When the detectors is operating as a multisensor (i.e. Modes 1, 3, and 4) the temperature signal processing extracts only rateofrise information for combination with the optical signal. In these modes the detectors will not respond to a slow temperature increase even if the temperature reaches a high level. A large sudden change in temperature can, however, cause an alarm without the presence of smoke, if sustained for 20 seconds. The process algorithms in modes 1 to 4 incorporate drift compensation.

20 Modes The characteristics of the five response modes are summarized below. Mode 1 has a very high smoke sensitivity combined with high temperature sensitivity. This gives a high overall sensitivity to both smoldering and flaming fires. Mode 2 has smoke sensitivity similar to that of a normal photoelectric detector, but has no response to temperature. This mode is therefore equivalent to a standard photo detector. This mode is suitable for applications in which wide temperature changes occur under normal conditions. Mode 3 has moderate smoke sensitivity combined with moderate sensitivity to heat. This combination is considered the optimum for most general applications since it offers good response to both smoldering and flaming fires. Mode 4 has lower than normal smoke sensitivity combined with high heat sensitivity. This makes it suitable for applications in which a certain amount of fumes or smoke is considered normal. Mode 5 has no smoke sensitivity at all, but give a pure heat detector response. In this mode the detector will respond to slowly changing temperature and has a fixed temperature alarm threshold at 135 F. The analog value in this mode will give the approximate air temperature over the range of 59 F to 131 F. In Mode 5, the smoke sensor is still active though it does not contribute to the analog signal. As a consequence, if the detector is used in a dirty or smoky environment the optical sensor drift flag may be activated in the heatonly mode. Engineering Specification The photo/heat multisensor detector shall be VF5603, where indicated on the plans, with one of the several addressable mounting base options available. The combination sensor head and twistlock mounting base shall be UL Listed and UL Listed as compatible with the Elite addressable fire alarm control panels. The photo/heat multisensor detector shell have 5 programmable sensitivity modes. The base shall permit free interchange of sensor heads without requiring any additional wring or additional programming of the head or base. The smoke sensor shall contain an integral LED that shall latch in then the unit goes Into alarm. Technical Specifications Stand current: 500μA Alarm current: 3.5mA Operating voltage: 1728 VDC Max. continuous operating temp: 140 F Min. continuous operating temp: 32 F Min. Operating temp: 4 F (no condensation/icing) Storage: 22 F to 176 F Detector weight: 3.68 oz Detector with base weight: 5.62 oz Dimensions: Diameter: 3.93, Height: 1.65, Height in base: 1.96 Ordering Codes Part number Description VF5603 Multisensor Detector VF Mounting Base VF Low Profile Relay Base VF5633 Isolator Base VF EZ Fit Low Profile Base VF Sounder Base VF5650 Blank PERT Cards VF5651 Preaddressed PERT Cards Note: In testing of the multisensor detector should be carried out as for smoke detector in response modes 14, and for heat detection in response mode 5. Design Note: If the multisensor is to be used in mode 5, heat detector spacing/coverage should be applied.

21 VF5669 P95A Ionization Smoke Sensor SLC Devices Sectional view P95A Ionization Smoke Detector Diagram showing lines of equipotential for the P95A Ionization Smoke Monitor Standard Features Responds well to fast burning, flaming fires Designed to operate in a variety of environments Minimal effects from temperature, humiditty, atmospheric pressure Overview The P95A Ionization Detector uses a low activity radioactive foil to detect fires by irradiating the air in smoke chambers and causing a current flow. If smoke enters the chamber, the current flow if reduced leading to an alarm. Operation The P95A Ionization Smoke Detector has a moulded selfextinguishing white polycarbonate case with wind resistant smoke inlets. Stainless steel wiper contacts connect the detector to the terminals in the mounting base. Inside the detector case is a printed circuit board that has the Ionization chamber mounted on one side and the address capture, signal processing and communications electronics on the other. The ionization chamber system is an inner reference chamber contained inside an outer smoke chamber. The outer smoke chamber has smoke inlet apertures that are fitted with an insect resistant mesh. The radioactive source holder and the outer smoke chamber are the positive and negative electrodes respectively. An Americium 241 radioactive source mounted within the inner reference chamber irradiates the air in both chambers to produce positive and negative ions. On applying a voltage across these electrodes an electric field is formed as shown in the diagram. The ions are attracted to the electrode of the opposite sign, some ions collide and recombine, but the net result is that a small electric current flows between the electrodes. At the junction between the reference and smoke chambers is the sensing electrode that is used to convert variations in the chamber currents into a voltage. When smoke particles enter the Ionization chamber, ions become attached to them with the result that the current flowing through the Ionization chamber decreases. This effect is greater in the smoke chamber than in the reference chamber and the imbalance causes the sensing electrode to go more positive. The voltage on the sensing electrode is monitored by the sensor electronics and is processed to produce a signal that is translated by the A/D converter in the communications ASIC ready for transmission when the device is interrogated. Electrical Description The detector is designed to be connected to a two wire loop circuit carrying both data and a 17V to 28V dc supply. The detector is connected to the incoming and outgoing supply via terminals L1 and L2 in the mounting base. A remote LED indicator requiring not more than 4mA at 5V may be connected between +R and R terminals. An earth connection terminal is also provided, although this is not required for the functioning of the detector. The detector is calibrated to give an analog value of 25±7 counts in clean air. This value increases with smoke density. A count of 55 corresponds to the UL alarm sensitivity level. See graph overleaf. Counts of 8 or less indicate fault conditions. Count levels between 45 counts and 55 counts can be used to provide an early warning of fire.

22 Electrical Characteristics The VF5669 Ionization Smoke Detectors are designed to operate in a wide variety of environments (See graphs). There are only small effects from temperature, humidity, atmospheric pressure and wind. Detectors are well protected against electromagnetic interference over a wide frequency range. TheVF5669 Ionization Detector, like all Ionization Detectors, has some sensitivity to air movement (wind). The extent to which the analog value will change depends on the wind speed and on the orientation of the detector relative to the wind direction. Relatively small changes in wind direction can cause significant changes in analog value. For wind speeds up to 1m/s (200ft/min) the change in analog value will not exceed 5 counts. Continuous operation in wind speeds greater than 2m/s (400ft/ min) is not recommended. However, wind speeds up to 10m/s (2000ft/min) can be tolerated for short periods and will not under any conditions increase the probability of false alarms. Technical Specifications Specifications are typical and given at 73 F and 50% relative humidity unless otherwise stated. Detection Principle: Ionization Chamber Chamber Configuration: Twin compensating chambers using one single sided ionising radiation source Radioactive Isotope: Americium 241 Activity: 33.3kBq, 0.9μCi Sampling Frequency: Continuous Sensitivity: Nominal threshold y value of 0.7 to UL Supply Wiring: Two wire supply, polarity insensitive Terminal Functions: L1&L2 supply in and out connections (polarity insensitive) +R remote indicator positive connection (internal 2.2kΩ resistance to supply +ve) R remote indicator negative connection (internal 2.2kΩ resistance to supply ve) Supply Voltage: 17 to 28 Volts dc Modulation Voltage at Detector: 5 to 9 Volts peak to peak Quiescent Current: 280μA average, 500μA peak Powerup Surge Current: 1mA Alarm Indicator: Red light emitting diode (LED) Alarm LED Current: 2mA Remote LED Current: 4mA at 5V (measured across remote load) Storage Temperature: 22 F to +176 F Operating Temperature: 4 F to +158 F Humidity: (No condensation or icing) 0% to 95% relative humidity Wind Speed: 10m/s maximum Atmospheric Pressure: Automatic compensation by dual chambers to maintain sensitivity up to a height of 6561m above sea level IP Rating: 23D Detector weight: 3.7 oz Detector with base weight: 5.68 oz Dimensions: Diameter: 3.93, Height: 1.65, Height in base: 1.96 Materials: Detector Housing: White polycarbonate V0 rated to UL 94 Terminals: Nickel plated stainless steel Analog Value (Counts) Obscuration in smoke db/m Typical response characteristics VF5669 Ionization Detector Analog Value (Counts) Temperature ( F) Typical temperature response VF5669 Ionization Detector Analog Value (Counts) Height (Ft) above sea level Typical pressure response VF5669 Ionization Detector Analog Value (Counts) Typical wind speed response VF5669 Ionization Detector

23 VF5670 P95A Photoelectric Smoke Sensor SLC Devices Top section P95A Photoelectric Smoke Detector Schematic Diagram P95A Photoelectric Smoke Detector Standard Features UL Listed and FM Approved Wind resistant smoke inlets Insect resistant screen Alarm flag for fast alarm reporting Automatic addressing with the PERT card Electronics free 4 or 6 bases Ease of installation Elegant design Responds well to slow burning, smouldering fires Well suited for bedrooms and escape routes Unaffected by atmospheric pressure Overview The VF5670 Photoelectric Smoke Detector works on the light scatter principle and is ideal for applications where slow burning or smouldering fires are likely. Operation The VF5670 Photoelectric detector uses the same outer case as the ionization smoke detector and is distinguished by the indicator LED which is clear in standby and red in alarm. Within the case is a printed circuit board which on one side has the light proof labyrinth chamber with integral gauze surrounding the optical measuring system and on the other the address capture, signal processing and communications electronics. An infrared light emitting diode within its collimator is arranged at an obtuse angle to the photodiode. The photodiode has an integral daylightblocking filter. The IR LED emits a burst of collimated light every second. In clear air the photodiode receives no light directly from the IR LED because of the angular arrangement and the dual mask. When smoke enters the chamber it scatters photons from the emitter IR LED onto the photodiode in an amount related to the smoke characteristics and density. The photodiode signal is processed by the optical ASIC and passed to the A/D converter on the communications ASIC ready for transmission when the device is interrogated. Electrical Description The VF5670 detector is designed to be connected to a two wire loop circuit carrying both data and a 17V to 28V dc supply. The detector is connected to the incoming and outgoing supply via terminals L1 and L2 in the mounting base. A remote LED indicator requiring not more than 4mA at 5V may be connected between the +R and R terminals. An earth connection terminal is also provided. The detector is calibrated to give an analog value of 25±7 counts in clean air. This value increases with smoke density. A count of 55 corresponds to the UL alarm sensitivity level. See graph overleaf. Environmental Characteristics The VF5670 Photoelectric smoke detector is unaffected by wind or atmospheric pressure and operates over the temperature range 4 F to +140 F. See graph overleaf.

24 Technical Specifications Specifications are typical and given at 73 F and 50% relative humidity unless otherwise stated. Detection Principle: Photoelectric detection of light scattered in a forward direction by smoke particles Chamber Configuration: Horizontal optical bench housing an infrared emitter and sensor arranged radially to detect scattered light Sensor: Silicon PIN photodiode Emitter: GaAs infrared light emitting diode Sampling Frequency: 1 second Sensitivity: Nominal response threshold value of 0.12 db/m when measured in accordance with UL Supply Wiring: Two wire supply, polarity insensitive Terminal Functions: L1&L2 supply in and out connections (polarity insensitive) +R remote indicator positive connection (internal 2.2kΩ resistance to supply +ve) R remote indicator negative connection (internal 2.2kΩ resistance to supply ve) Quiescent Current: 340μA average, 600μA peak Powerup Surge Current: 1mA Alarm Indicator: Clear light emitting diode (LED) emitting red light Alarm LED Current: 4mA Remote LED Current: 4mA at 5V (measured across remote load) Storage Temperature: 22 F to +176 F Operating Temperature: 4 F to +140 F Humidity: (No condensation or icing) 0% to 95% relative humidity Wind Speed: Unaffected by wind Atmospheric Pressure: Unaffected IP Rating: 23D Detector weight: 3.7 oz Detector with base weight: 5.54 oz Dimensions: Diameter: 3.93, Height: 1.65, Height in base: 1.96 Materials: Detector Housing: White polycarbonate V0 rated to UL 94 Terminals: Nickel plated stainless steel Analog Value (Counts) Obscuration in smoke db/m Typical response characteristics VF5670 Photoelectric Smoke Detector Analog Value (Counts) Temperature ( F) Typical temperature response VF5670 Photoelectric Smoke Detector Overheating/thermal combustion Smouldering/ glowing combustion Flaming combustion Flaming with high heat output Flaming clean burning Photoelectric Detector Very Good Moderate/ Good Very Good Very Good Poor Response characteristics of the VF5670 Photoelectric Detector

25 VF5668 P95A Heat Detector SLC Devices Sectional view P95A Heat Detector Schematic Diagram P95A Heat Detector Standard Features UL Listed and FM Approved Electronic temperature sensing Style 4, 6, or 7 communication wiring LED indicator Alarm flag for fast alarm reporting Alarm address for fast location of alarm Automatic addressing with the PERT card Electronics free 4 or 6 bases Slideeasy bases Ease of installation Elegant design Ideal for environments that are dirty or smoky under normal circumstances Well suited for warehouses, loading bays and parking areas Unaffected by wind or atmospheric pressure Overview The P95A series analog addressable heat detector head, model VF5668, is molded from white polycarbonate material with a low air flow resistance design. Stainless steel wiper contacts connect the sensor to the terminals, which are polarity insensitive, in the mounting base. Inside the sensor case is a circuit board with the sensing system on one side and the address capture, signal processing, and communication electronics on the other side. The sensor monitors temperature by using a single thermistor network, which provides a voltage output proportional to the external air temperature. This analog voltage is converted to a digital signal, which is transmitted to the Elite Fire Alarm Control Panel for interpretation. The alarm threshold is programmed into the Elite Fire Alarm Control Panel. Operation The P95A heat detectors have a common profile with ionization and photoelectric smoke detectors but have a low air flow resistance case made of self extinguishing white polycarbonate. The devices monitor heat by using a single thermistor network which provides a voltage output proportional to the external air temperature. The standard heat detectors respond to increasing air temperature in such a way that they are classified as an A2S device. See graph overleaf. Both devices will give 55 counts at 131 F. A high temperature CS heat detector which can be installed in a typical ambient temperature of 131 f is available. See graph overleaf. This device will give 55 counts at 194 F. Electrical Description The detectors are designed to be connected to a two wire loop circuit carrying both data and a 17V to 28V dc supply. The detectors are connected to the incoming and outgoing supply via terminals L1 and L2 in the mounting base. A remote LED indicator requiring not more than 4mA at 5V may be connected between +R and R terminals. An earth connection terminal is also provided. The detector is calibrated to give an analog value of 25±5 counts at 77 F. Environmental Characteristics P95A Standard Heat Detectors operate over the range 4 F to +158 F, the High Temperature Heat Detectors operate over the range 4 F to +248 F. The detectors are unaffected by atmospheric pressure.

26 Technical Specifications Specifications are typical and given at 73 F and 50% relative humidity unless otherwise stated. Detection Principle: Linear approximation over temperature range 77 F to 194 F Sensor: Single NTC Thermistor Sampling Frequency: Continuous Sensitivity: 77 F to 194 F: 38 F/count 4 F returns 8 counts Supply Wiring: Two wire supply, polarity insensitive Terminal Functions: L1&L2 supply in and out connections (polarity insensitive) +R remote indicator positive connection (internal 2.2kΩ resistance to supply +ve) R remote indicator negative connection (internal 2.2kΩ resistance to supply ve) Supply Voltage: 1628VDC Modulation Voltage at Detector: 5 to 9 Volts peak to peak Quiescent Current: 250μA average, 500μA peak Powerup Surge Current: 1mA Alarm Indicator: Red light emitting diode (LED) Alarm LED Current: 2mA Remote LED Current: 4mA at 5V (measured across remote load) Alarm Temperature: 135 F (57 C) (55 counts in 7 bits or 110 counts in 8 bits) UL class Ordinary Style: Styles 4, 6, and 7 Terminations: (Detector Head) Stainless steel wiper contacts EndofLine resistor: None Address Setting: PERT Card Mounting: 4 or 6 round base Termination: Field Wiring/Base Stainless Steel, Nickel Plated Storage Temperature: 22 F to +176 F Operating Temperature: 4 F to +158 F Humidity: (No condensation or icing) 0% to 95% relative humidity Wind Speed: Unaffected in fixed temperature use Atmospheric Pressure: Unaffected IP Rating: 53 Detector weight: 3.7 oz Detector with base weight: 5.54 oz Dimensions: Diameter: 3.93, Height: 1.65, Height in base: 1.96 Materials: Detector Housing: White polycarbonate V0 rated to UL 94 Terminals: Nickel plated stainless steel Analog Value (Counts) Temperature ( F) Typical response characteristics VF5668 Standard Heat Detector Analog Value (Counts) Temperature ( F) Typical response characteristics VF5668 High temperature Heat Detector Heat Detector Overheating/thermal combustion Very Poor Smouldering/ glowing combustion Very Poor Flaming combustion Poor Flaming with high heat output Moderate/ Good Flaming clean burning Moderate/ Good Response characteristics of the VF5668 Heat Detector

27 VF5671 P95A Multisensor Detector SLC Devices Sectional view Multisensor Detector Standard Features Sleek, nonfading white polycarbonate enclosure Zero insertion force base For easier installation and maintenance Alarm flag for accelerated alarm reporting. Evaluates combined signals from ROR heat sensing element and smoke sensing chamber Dual LED s for 360 degree Visibility Sensitive to a wide range of fires Well suited for environments such as hotel bedrooms or warehouse loading bays Unaffected by wind or atmospheric pressure Overview The P95A VF5603 multisensor is basically an optical smoke detector and will therefore respond well to smoke from smouldering fires. The multisensor detector also senses air temperature. This temperature sensitivity allows the multisensor to give a response to fast burning (flame) fires, which is similar to that of an ionization detetctor. The multisensor can therefore be used as an alternative to an ionization detector. Operation The VF5671 Multisensor Detector contains an optical smoke sensor and a thermistor temperature sensor whose outputs are combined to give the final analog value. The Multisensor construction is similar to that of the photoelectric detector but uses a different lid and optical mouldings to accommodate the thermistor temperature sensor. The sectional view shows the arrangement of the optical chamber and thermistor. The signals from the optical smoke sensing element and the temperature sensor are independent, and represent the smoke level and the air temperature respectively in the vicinity of the detector. The detector s microcontroller processes the two signals. The temperature signal processing extracts only rate of rise information for combination with the optical signal. The detector will not respond to a slow temperature increase even if the temperature reaches a high level. A large sudden change in temperature can, however, cause an alarm without the presence of smoke, if sustained for 20 seconds. The processing algorithms in the multisensor incorporate drift compensation. The sensitivity of the detector is considered the optimum for most general applications since it offers good response to both smouldering and flaming fires.

28 Technical Specifications Specifications are typical and given at 73 F and 50% relative humidity unless otherwise stated. Detection Principle: Smoke: Photoelectric detection of light scattered by smoke particles Heat: Temperaturesensitive resistance Supply Wiring: Two wire supply, polarity insensitive Terminal Functions: L1&L2 supply in and out connections (polarity insensitive) +R remote indicator positive connection (internal 2.2kΩ resistance to supply +ve) R remote indicator negative connection (internal 2.2kΩ resistance to supply ve) Operating voltage: 1728V DC Communications protocol: Apollo P95 59V peak to peak Quiescent current: 500μA average 750μA peak Powerup surge current: 1mA Maximum powerup time: 10s Alarm LED current: 3.5mA Remote LED current: 4mA at 5V (measured across remote load) Clean air analog value: 23 +4/0 Alarm level analog value: 55 Alarm indicator: 2 colorless Light Emitting Diodes (LEDs); illuminated red in alarm Optional remote LED Temperature range: Max. continuous operating: +140 F Min. continuous operating: 32 F Min. operating (no condensation/icing): 4 F Storage 22 F to +176 F Humidity: (No condensation) 0 to 95% relative humidity Effect of temperature on optical detector: Less than 15% change in sensitivity over rated range. Slow changes in ambient conditions will automatically be compensated and will not affect sensitivity Effect of atmospheric pressure on optical sensor: None Effect of wind on optical sensor: None IP rating: 23D Detector weight: 3.7 oz Detector with base weight: 5.64 oz Dimensions: Diameter: 3.93, Height: 1.96, Height in base: 2.28 Materials: Detector Housing: White polycarbonate V0 rated to UL 94 Terminals: Nickel plated stainless steel Technical Specifications Smoke element only: Chamber configuration: Horizontal optical bench housing infrared emitter and sensor, arranged radially to detect forward scattered light Sensor: Silicon PIN photodiode Emitter: GaAs infrared light emitting diode Sampling frequency: 1 per second Overheating/thermal combustion Smouldering/ glowing combustion Flaming combustion Flaming with high heat output Flaming clean burning Multisensor Detector Very Good Good Good Very Good Moderate/ Good Response characteristics of the VF5671 Multisensor Detector

29 VF5604 Optical Beam Detector SLC Devices Standard Features Looppowered Compatible with P95 and Discovery Four selectable alarm levels Drift compensation Remote interface Simple wiring Simple alignment Overview P95 Looppowered Beam Detector The P95 beam detector has been designed to protect large open spaces such as atria, museums, churches, warehouses and factories. It is made up of three main parts: the transmitter, which projects a beam of infrared light, the receiver, which registers the light and produces an electrical signal, and the interface, which processes the signal and generates alarm or fault signals. The transmitter and receiver are designed to be fitted on opposite walls approximately 1ft to 2ft below the ceiling. They can protect areas up to 328ft long and 49ft wide, a total of 1794yds 2. If it is difficult to fit the transmitter and the receiver to opposite walls, they may be fitted in retro mode, ie, adjacent to each other on the same wall. A reflector needs to be fitted to the opposite wall to reflect the beam from the transmitter to the receiver. The interface contains the electronic circuitry needed to control the beam detector and communicate with the control panel via the P95 or Discovery loop. In clear air the receiver registers all the light sent by the transmitter. If smoke from an incipient fire is present, it rises and obscures the light to a certain extent. The decrease in the amount of light registered by the receiver causes the beam detector to change to the alarm state. The detector compensates for signal drift and, if the limit of compensation has been reached, a fault signal is generated; the detector may optionally be set to return a fault if the beam is totally and suddenly obscured. Looppowered The P95 beam detector has been developed from designs that have been well proven in countless fire protection systems. A major advance has, however, been made, in that the P95 beam detector is Looppowered and needs no separate 24V supply. This not only eliminates the need for additionalequipment it also saves both cost and time in installation. Compatibility The beam detector operates as a conventional detector, in that it changes to the alarm state at a preset level of smoke obscuration, but is able to communicate with the control panel and return information when interrogated. The interface will operate on both the P95 and the Discovery protocols. Selectable Alarm Levels The P95 beam detector is set on commissioning to one of four levels of obscuration, determined with reference to the environment in which it is installed. The levels are 25%, 35%, 50% and 65%, where 25% is the most sensitive and 65% the least sensitive level. A DIL switch on the interface is used to set the obscuration level. Drift Compensation It is possible that the amount of light registered by the receiver is decreased by factors other than incipient fires. The most obvious cause of such a change is contamination of the lens of the receiver. In order to minimise the risk of unwanted alarms, the P95 beam detector checks its status at regular intervals and compensates for positive drift of signal. The analog value sent to the control panel is preset and cannot be further compensated by the panel. Remote Interface The optical and electronic elements of the P95 beam detector are separate from one another, with the majority of the electronics being housed in the interface. The advantage of this is that the interface may be installed in an accessible position. If it is required to service the electronics of the beam detector, this can be done without the need for access equipment. Simple Wiring The transmitter and the interface of the P95 beam detector can be wired to the nearest point of the loop. No extra wiring is necessary for any purpose. Simple Alignment During commissioning it is necessary to align the transmitter and receiver so that the beam is correctly projected at the receiver. By its nature the beam is invisible to the human eye, so that alignment has traditionally been a complex procedure. The P95 beam detector makes alignment simple a highbrightness LED behind the receiver lens flashes while the transmitter is being aligned. Once alignment is correct, the LED stops flashing.

30 Ordering Codes Part number VF5611 VF5612 VF5613 VF5614 Description Spare Transmitter Spare Interface Spare Reflector Spare Resistor Technical Specifications Supply Voltage: 1728V DC Quiescent 24V DC: 10.5mA (Receiver and Interface), 6.0mA (Transmitter) Alarm 24V DC: 12.0mA (Receiver and Interface), 6.0mA (Transmitter) Fire Alarm Thresholds: 25% Obscuration (1.25dB) 35% Obscuration (1.87dB) 50% Obscuration (3.00dB) 65% Obscuration (4.55dB) Operating Range: 25% Obscuration: 32ft140ft (1042m) 35% Obscuration: 32ft215ft (1064.5m) 50% Obscuration: 70ft328ft (21100m) Retro Mode with relectors: 65% Obscuration: 20ft148ft (645m) Tolerance to Beam Misalignment at 35% obscuration: Transmitter +1.0 o ; Receiver +4 o, 880nm (Optical wavelength) Receiver/ Interface Cable Type and Max. Length: Twin twisted pair 7/31 AWG (7/0.2), 1 pair A&B, 1 pair C&D 328ft (100m) Finish: White IP Rating: 50 Operating Temperature: +16 o F to +131 o F (10 o C to +55 o C) Factory Default Settings Fire Alarm Threshold: 35% Alarm on Total Obscuration: Trouble Alignment Mode/ Normal Operation: Alignment Mode Address: 1

31 VF4991 Duct Smoke Detector SLC Devices Standard Features LowFlow Technology: Both Ionization and Photoelectric models listed for velocities between ft./min Both Ionization and Photoelectric models listed for high temperature applications Units supplied with slidein PERT Card for easy device addressing Patent pending NoTools Required front or rear loading and removing sampling/exhaust tubes Patent pending Test Port Valve allows for aerosol smoke testing without cover removal Clear cover fitted with four captive NoTools Required thumbscrews Instantaneous cover removal trouble indication Vertical terminal block for easier wiring Steady red LED on detector head indicates alarm More wiring space than competitive models Footprint allows easy retrofit in many applications without additional drilling Duct wall gaskets on back of enclosure are preinstalled Compatible with the WP2000 weatherproof enclosure External mounting tabs do not require cover removal to install Colored cover gasket indicates proper cover seal UL, CUL, Listed; CSFM, MEA pending Compact, lightweight size means easy handling, lower shipping costs Large terminal connection screws P95A interchangeable plugin UL268 photoelectric or ionization heads Advanced detector head design yields internal dust filtering No additional screens or filters to clean Compatible with fire alarm systems utilizing Apollo P95 and/or Discovery protocol Ionization and Photoelectric versions available Complete wiring details permanently attached to unit Overview The VF4991 Series Smoke Duct Detector is the latest analog addressable innovation for early detection of smoke and products of combustion present in air moving through HVAC ducts in Commercial, Industrial, and Residential applications. The unit is designed to prevent the recirculation or spread of smoke by air handling systems, fans, and blowers. Complete systems may be shut down via the building s fire alarm control panel (FACP) in the event of smoke detection. The VF4991 is designed and built to meet all local code requirements, as well as the NFPA and ICC standards regarding HVAC supply and return duct smoke detectors. Output terminals are provided for a remote alarm indicator accessory. The VF4991 includes many features that represent true innovations from current generation duct smoke detectors. Our traditional installer/servicerfriendly approach has been closely followed and expanded throughout the VF4991. This philosophy provides a new level of efficiency in afterpurchase value to both the installer/servicer and enduser. Our attention to detail has yielded a host of NoTools Required features, as well as a multiapplication performance level as yet unmatched in the industry. The key features below detail many of the customerdriven innovations incorporated in the VF4991 Series. Innovative product combined with unsurpassed customer service equals the right combination for all of your projects.

32 Technical Specifications Model Number: VF4991 Ionization, VF4991 Photoelectric P95A Detector Model Number: VF4991 Ionization APO, VF4991 Photoelectric APO Sampling Tubes: STN1.0 Sampling tube for 12 or less duct width, STN2.5 Sampling tube for 6 to 2.5 duct width STN5.0 Sampling tube for 2.5 to 5.0 duct width, STN10.0 Sampling tube for 5.0 to 10.0 duct width Accessories: MSRA, RD remote alarm indicators, WP2000 weatherproof enclosure and TG2000 aerosol test gas (All available from Air Products and Controls Inc.) Detector Compatibility: FACP utilizing Apollo P95 and/or Discovery protocols Air Velocity: 100 to 4,000 ft./min. Ambient Temperature: SLDAAN 32ºF to 150ºF (0ºC to 66ºC), SLDAAP 32ºF to 140ºF (0ºC to 60ºC) Humidity: 10 95% RH NonCondensing / NonFreezing Wiring: Solid or stranded: #12 to #22 AWG terminals Approvals: UL & CUL Listed (UL268A, URO, URO7) File # S2829, CSFM Listed ( :115), MEA Accepted (7392E Vol.35) Material: Grey plastic backbox, clear plastic cover (Makrolon 94V0) Dimensions: 13 1/2 L x 4 1/2 W x 2 1/4 H Max. Net Wt.: 2 lbs. Radioactive Element: For SLDAAN (Ionization) Americium 241; 0.9 MicroCurie. Do not expose to corrosive atmospheres Hardware: 7 exhaust tube, sampling tube end cap, mounting template and mounting hardware included Engineers and Architects Specifications Air duct smoke detectors shall be Air Products and Controls Inc. SLDAA Series. For ionization detectors the model number is SLDAAN. For photoelectric detectors the model number is SLDAAP. The detectors shall be listed by Underwriters Laboratories per UL 268A. The detectors shall operate at air velocities from 100 feet per minute to 4,000 feet per minute and at temperatures of no greater than 140 F (60 C). Visual indication of alarm must be provided on the detector. Air handling unit shut down shall be accommodated via the associated FACP. Detector head shall not require additional filters or screens which must be maintained. The housing shall contain a detector base which will accept photoelectric or ionization detector heads as well as a means of detector addressing. Terminal connections shall be of the screw type, a minimum of #6 screw (#12 to #22 AWG compatible). Terminals shall be provided for remote alarm indication. All wiring must comply with local codes and regulations. A method of smoke testing the detector without removing the cover must be provided. All unit and remote accessory connection designations must be permanently affixed to the unit. Cover and sampling/exhaust tube installation or removal must not require the use of tools. Sample and exhaust tubes shall be capable of removal/installation from the front and/or rear of the detector for inspection/ maintenance.

33 VF4992 Duct Smoke Detector SLC Devices Standard Features LowFlow Technology: Both Ionization and Photoelectric models listed for velocities between ft./min Both Ionization and Photoelectric models listed for high temperature applications Operating voltages: 24VAC or 24VDC Units supplied with slidein PERT Card for easy device addressing Patent pending NoTools Required front or rear loading and removing sampling/ exhaust tubes Standard Features Patent pending Test Port Valve allows for aerosol smoke testing without cover removal Clear cover fitted with four captive NoTools Required thumbscrews Instantaneous cover removal trouble indication Inline terminal block for easier wiring Steady red LED on detector head indicates alarm operation More wiring space than competitive models Footprint allows easy retrofit in many applications without additional drilling Over 15 remote accessories available Duct wall gaskets on back of enclosure are preinstalled Compatible with the WP2000 weatherproof enclosure Builtin alarm relay test switch Unit includes green pilot and red alarm visual indicators External mounting tabs do not require cover removal to install Colored cover gasket indicates proper cover seal UL, CUL Listed; CSFM, MEA pending Compact, lightweight size means easy handling, lower shipping costs One set of 15A form C alarm contacts Large terminal connection screws P95A interchangeable plugin UL268 photoelectric or ionization heads Advanced detector head design yields internal dust filtering No additional screens or filters to clean Compatible with fire alarm systems utilizing Apollo P95 and/or Discovery protocol Ionization and Photoelectric versions available Complete wiring details permanently attached to unit Overview The VF4992 Series Smoke Duct Detector is the latest analog addressable innovation for early detection of smoke and products of combustion present in air moving through HVAC ducts in Commercial, Industrial, and Residential applications. The unit is designed to prevent the recirculation or spread of smoke by air handling systems, fans, and blowers. Complete systems may be shut down via the unit s onboard alarm contact in the event of smoke detection. The VF4992 is designed and built to meet all local code requirements, as well as the NFPA and ICC standards regarding HVAC supply and return duct smoke detectors. Output terminals are provided for a wide range of remote accessories such as horns, strobes, remote status indicators and test key switches or push buttons. The VF4992 includes many features that represent true innovations from current generation duct smoke detectors. Our traditional installer/servicerfriendly approach has been closely followed and expanded throughout the VF4992. This philosophy provides a new level of efficiency in afterpurchase value to both the installer/servicer and enduser. Our attention to detail has yielded a host of NoTools Required features, as well as a multiapplication performance level as yet unmatched in the industry. The key features below detail many of the customerdriven innovations incorporated in the VF4992 Series. Innovative product combined with unsurpassed customer service equals the right combination for all of your projects.

34 Terminal Connections UL LISTED COMPATIBLE FACP SLC (LOOP) + L1 L2 C+ T+ P+ AL+ C TB+ NC COM NO 24V N/O FACP SLC SUPERVISED UNSUPERVISED + OUT + IN TEST + OUT PILOT + OUT ALRM REMOTE ACCESSORY OUT Technical Specifications ALARM CONTACT 15A@125VAC 10A@277VAC 7A@30VDC 1/4HP@125/250VAC(NC) 1/3HP@125/250VAC(NO) + OUT TRBL ALARM RELAY AC/+ N/O POWER 24AC/DC Model Number: VF4992 Ionization 24VAC or 24VDC, VF4992 Photoelectric 24VAC or 24VDC Remote Accessory Wiring P95A Detector Model Number: VF4992 Ionization APO, VF4992 Photoelectric APO Detector Compatibility: FACP utilizing Apollo P95 and/or Discovery protocols Sampling Tubes: STN1.0 Sampling tube for 12 or less duct width, STN2.5 Sampling tube for 6 to 2.5 duct width STN5.0 Sampling tube for 2.5 to 5.0 duct width, STN10.0 Sampling tube for 5.0 to 10.0 duct width Accessories: MS and MSR Series Remote accessories,wp2000 weatherproof enclosure and TG2000 aerosol test gas and TPB power supplies (All available from Air Products and Controls Inc.) Control Board Power Requirements (without accessories): Standby 24VAC, 105mA; 24vDC, 26mA: Alarm 24VAC, 195mA; 24VDC 54mA Relay Contact Rating Alarm Contacts: Resistive load: 1 set form C rated at 125VAC, 277VAC, 54mA Inductive Load: 1/4 125/250VAC (NC), 1/3 125/250VAC (NO) Air Velocity: 100 to 4,000 ft./min. Ambient Temperature: SLDA4RN 32ºF to 150ºF (0ºC to 66ºC), SLDA4RP 32ºF to 140ºF (0ºC to 60ºC) Humidity: 10 95% RH NonCondensing / NonFreezing Wiring: Solid or stranded: #12 to #22 AWG terminals Approvals: UL & CUL Listed (UL268A, URO, URO7) File # S2829, CSFM Listed ( :116), MEA Accepted (7392E Vol.36) Material: Grey plastic backbox, clear plastic cover (Makrolon 94V0) Dimensions: 13 1/2 L x 4 1/2 W x 2 1/4 H Max. Net Wt.: 2.25 lbs. Radioactive Element: For SLDA4RN (Ionization) Americium 241; 0.9 MicroCurie. Do not expose to corrosive atmospheres Hardware: 7 exhaust tube, sampling tube end cap, mounting template and mounting hardware included Engineers and Architects Specifications Air duct smoke detectors shall be Air Products and Controls Inc. SLDA4R Series. For ionization detectors the model number is SLDA4RN. For photoelectric detectors the model number is SLDA4RP. The detectors shall be listed by Underwriters Laboratories per UL 268A. The detectors shall operate at air velocities from 100 feet per minute to 4,000 feet per minute and at temperatures of no greater than 140 F (60 C). Visual indication of alarm must be provided on the detector front. A manual alarm relay/test switch located on the front of the device shall be provided. Detector head shall not require additional filters or screens which must be maintained, and control board shall include both a standby and alarm visual indications. The housing shall contain a detector base which will accept photoelectric or ionization detector heads as well as a means of detector addressing. Terminal connections shall be of the screw type, a minimum of #6 screw (#12 to #22 AWG compatible). Terminals shall be provided for remote pilot, remote alarm indications, strobe/horn, and remote test switch. All wiring must comply with local codes and regulations. A method of smoke testing the detector without removing the cover must be provided. All unit and remote accessory connection designations must be permanently affixed to the unit. Cover and sampling/exhaust tube installation or removal must not require the use of tools. Sample and exhaust tubes shall be capable of removal/installation from the front and/or rear of the detector for inspection/maintenance. C+ TR+ P+ AL+ C TB+ SLD4R C+ KEY OR PUSH BUTTON TR+ TEST SWITCH GREEN P+ PILOT LED RED ALARM AL+ LED AND/OR STORBE/HORN C YELLOW TROUBLE LED TB+ MSR SERIES REMOTE ACC. MS SERIES REMOTE ACC.

35 VF3033 Single Action Addressable Pull Station SLC Devices VF3034 Dual Action Addressable Pull Station Standard Features Single or Dual Action Wire head Connections Gold Plated Alarm Contacts Surface or Weatherproof Backbox Optional Auxiliary Alarm Contacts Optional Station Colors Combined with the VF5663 or VF5608 to provide an addressable interface to the Elite SLC loop Application The VF3033 and VF3034 are versatile, highquality, metal Fire Alarm Pull Stations designed to meet any installation demand. Available in both single (VF3033) and dual action (VF3034) configurations. VF3021 and VF3022 pull stations are integrated with the analog single contact module to provide a simpletoinstall addressable pull station. The normally open contact of each station, which closes when the pull station is activated, is rated for 1 Amp, 30VDC. The contacts are gold plated to avoid risk of corrosion. All VF3033 and VF3034 models have been tested by UL and found in compliance to the latest requirements of the American s With Disabilities Act (ADA). VF3033 / VF3034 stations from VES are available with key reset. Key reset models are available for interchangeable keys. All models mount on a standard, single gang backbox, VES VF interior surface metal backbox or model VF weatherproof backbox interior surface metal backbox or model VF weatherproof backbox. Product Overview The VF3033 and VF3034 series pull stations are operated by pulling the handle marked PULL on the front of the station as far down as it will go. At that point, the station will lock in place and is easily visible from up to 50 feet. The activation handle is reset by opening the station with the hex wrench or key, placing the handle in the normal upright position and relocking the station. On the dual action, the push bar rotates inward allowing the PULL handle to be grasped and operated by a single hand. When used with the VF6001 Fast Response Contact Module, each addressable contact monitoring module is programmed with its own unique Signaling Line Circuit (SLC) loop address. Up to 126 devices can be placed on the Elite SLC loop. The module supervises the wiring to the contact with an End Of Line (EOL) resistor. It can be programmed to monitor normally open (NO) or normally closed (NC) contacts. If a fault condition occurs in the wiring, the module sends a trouble status signal to the fire alarm control panel. When a change of status is sensed by the fast response contact module, it sends an interrupt to the control panel indicating that an alarm has occurred. After addressing, Manual Pull Stations are fully configurable through Loop Explorer.

36 Engineering Specification The Dealer shall furnish and install where indicated on the plans, dualchamber ionization sensors, VES part number VF3033 or VF3034, depending on customer or specifier requirements. Stateoftheart communications protocol, DCP, allows multiple system component types to be used concurrently in a system s signal conditioning loop. Technical Specifications Rated voltage DCP powered loop: 1741 VDC Average consumption: 3.5mA Alarm current: 1728 VDC Transmission: DCP Digital Communication Protocol Maximum humidity: 90% RH noncondensing UL ambient installation temperature range: 32 F to 100 F Operating temperature range: 14 F to 122 F Color & case material: Red Typical Wiring Diagram Ordering Codes Part number VF3033 VF3034 VF VF VF VF5608 or 63 Description Single action addressable pull station Dual action addressable pull station Interior surface sheet metal backbox red Weatherproof surface die cast metal backbox and gasket assembly red Scored plastic (acrylic) breakrods (1 dozen per pack) Fast response contact module Note: All models are supplied with one scored, acrylic breakrod & one key

37 VF4990 Multi Flex Sounder Base Analog Addressable Sounder Bases Standard Features Compatible panel silence functions Sync network self tests to ensure synchronized output if upstream sync signal is lost Sounders will operate in failsafe mode if sync network is compromised Sync modules available in MR1 enclosures, snap track or chassis mount for standard 2gang box Intelligent trouble reporting via onboard Trouble LED Overview The MultiFlex family of the smoke detector sounder cases and synchronization modules provide today s most advanced functionality and performance, delivering flexible notification capabilities for Apollo conventional and analog addressable systems. The bases offer selectable steady or temporal pattern output and selectable high or low volume levels. The threepulse temporal pattern is required by NFPA 72 for fire alarm evacuation for commercial and residential applications. Available synchronization modules (SM) allow temporal pattern sounder base circuits to be completely synchronized and installed in almost limitless configurations, and also provide an onboard latching test function. The sounder base requires an external 24VDC power supply. in the absence of a synchronization module, a means for polarity reversal is required for test and general alarm functionality. The connections for the external power supply and the communication loop are optoisolated to prevent electrical interaction between them. Technical Specifications Multi Flex Sounder Base Sounder Base Part Number Compatible Smoke Detectors Sounder Base Operating Voltage Sounder Base Alarm Currents Sounder Base Standby Current Sounder Base Audible Intensity Wiring Environmental Material Dimensions Approvals MDSDRTAA MBSDRTCV Analog Addressable (Discovery or P95A) Conventional (Series 65 or Series 60A) 1730VDC (24VDC nominal) External Supply: 24VDC Assocaited Detector: 24VDC 24VDC High Volume Selection: 10 feet Low Volume Selection: 24VDC Solid or Stranded; #12 to #22 AWG Terminals 32 o F to 100 o F (0 o C to 38 o C) 0% to 85% RH; NonCondensing/ NonFreezing Makrolon 6455 or 6555 (polycarbonate); 94V0 6 L x 6 W x 1.6 D (152mm x 152mm x 41mm) UL Listed File Pending CSFM Pending MEA Pending

38 Technical Specifications Multi Flex Synchronization Module MDSDRTSM/G MBSDRTSM/G/R MBSDRTSM/T MBSDRTSM/C MBSDRTSM/C/R TwoGang Box Mounted (H x W x D) Track Mounted (H x W x D) Enclosure Mounted (H x W x D) Cover Material Enclosure/ Mounting Details Operating Voltage Range Current Requirements Input/ Output Details Intelligent Trouble Reporting Wiring Environmental Approvals White ABS plastic; 94V0 3.3 (83.82mm) 2.6 (66.04mm) 0.77 (19.56mm) Red ABS plastic; 94V0 Metal 2Gang Mounting Chassis with Appropraite Wall Plate Cover 3.4 (87mm) 2.75 (69.85mm) 1.22 (30.99mm) Lowprofile Snap Track with Provided Mounting Screws Gray ABS plastic; 94V (131mm) 3.13 (80mm) 2.5 (64mm) Red ABS plastic; 94V0 18Ga. CRS, Plated with 1/2 Conduit Knockouts, Top and Bottom 1730VDC FWR Unfiltered (24VDC nominal) 24VDC Power Circuit (SM): 16mA Standby; 16mA Alarm SIL NAC Silence Circuit (SM): 7.5mA Standby; 2mA Alarm SYNC IN Synchronization Signal In (SM): 4mA Standby; 15mA Alarm TROUBLE: Always FACP monitored and reported as trouble or supervisory in all program modes. Dry N.O. contact held closed by the Powerower 24VDC input being present and the internal module circuitry being fully operational. Also supervises the presence of a sync in signal when module is programmed in the secondary or sync only modes. It is not used when the module is programmed in the main mode. GENERAL ALARM: 24VDC steady or pulsed, silenceable, polarized FACP NAC Input. This input is used only when the module is programmed in the main or sync only modes. When the connected NAC is in the alarm state the module will provide a general alarm signal to all associated sounder/relay bases, causing them to sound if a horn enable alarm input is also present. HORN ENABLE: 24VDC steady or pulsed, silenceable polarized FACP NAC input. This input is used only when the module is programmed in the main or sync only modes. When the connected NAC is in the alarm state the module will be active and ready to accept a general alarm input. The status of the connected NAC will also be monitored for subsequently being silenced from the FACP and will provide that signal to all associated sounder bases, causing them to silence. Subsequent alarms will resound as signalled from the FACP NAC connected to this input. SYNC IN: 24VDC/protocol feed input from associated module programmed in the main, secondary or sync only mode. This input is always used when the module is programmed in the secondary or sync only modes. It is not used when the module is programmed in the main mode. SYNC OUT: 24VDC/protocol feed output from module in all modes. When the module is programmed in the main or sync only modes, also provides distinct horn enable and general alarm status information to all associated sounder/relay bases and any modules programmed as secondary. POWER 24VDC: 24VDC power feed in always required in all modes. When the module is programmed in the sync only mode this input could be from a shared power supply with the associated main programmed module. When the module is programmed in the secondary mode this input will always be supplied from a new additional power source since that is the only reason it is being installed. Trouble LED: ON Test Mode SINGLE BLINK Sync In (when in main mode) Double Blink No Sync In (when in secondary mode) Triple Blink Output Short Solid or Stranded; #12 to #22 AWG Terminals 32 o F to 100 o F (0 o C to 38 o C) 0% to 85% RH; NonCondensing/ NonFreezing UL Listed File Pending CSFM Pending MEA Pending

39 Sensor Bases VF5635 Low Power Relay Base The VF5635 Low Power Relay Base incorporates a low power relay to control field equipment such as automatic door closers. Gives a set of voltage free contacts controlled by the remote output of a detector Draws negligible current VF5630 Mounting Base 4 VF5636 Mounting Base 6 All detectors fit the VF5630 and VF5636 Mounting Bases which are low insertion force bases with stainless steel contacts for the detector terminals. PERT cards are supplied with all bases. PERT addressing One way fit Locking feature to prevent unauthorized removal VF5632 EZ Fit Base The EZ fit base is a low profile 6 mounting base for ACC detectors. High degree of protection against unauthorized removal VF5640 Blank PERT Card A Universal address card supplied with all bases. Using a coding guide, pips are removed to set the address of the inserted detector. Simplifies and speeds up installation and commissioning Uses patented, proven technology Address remains the same, no matter how often detectors are replaced Flexibility to create any address

40 SLC Isolators VF5633 Isolating Base The VF5633 Isolating Base senses and detects short circuit faults on SLC loops. Up to 20 devices may be installed between isolating bases PERT addressing VF5605 Isolator The VF5605 Isolator is placed at intervals on the loop and ensures that, in the case of a short circuit, only the section between the isolators will be affected. When the short circuit is removed, the isolators automatically restore power and data to the isolated section. Detects wiring shortcircuits using patented technology Minimizes disruption from shortcircuits Automatic deisolation on shortcircuit removal Up to 20 devices may be installed between isolators VF5634 Isolator Base The VF5634 Isolator Base is unique and designed to only accept the Isolator. Only accepts isolators

41 The Mini Priority Switch Monitor is designed to monitor the state of one or more single pole, volt free contacts and to report the status to Apollo compatible analog control equipment. It can also place a signal on the loop to provide early warning if a device such as a pull station is operated. Three input states normal, fault and alarm Visible LED with remote LED connection option Loop powered Designed to fit into equipment with limited space Easy to install Monitors equipment where a fast response is required Interrupt facility Class A or B input capability Mini Input Modules VF5660 Mini Priority Switch Monitor Module VF5661 Mini Switch Monitor Module The VF5661 Mini Switch Monitor Module is designed to monitor the state of one or more single pole, volt free contacts and to report the status to Apollo compatible analog control equipment. Three input states normal, fault and alarm Visible LED with remote LED connection option Loop powered Designed to fit into equipment with limited space Easy to install VF5608 Mini Monitor Module The New Mini Monitor Module is an interface within a entirely new housing. This allows the unit to be fitted onto a standard 35mm DINrail (using a twistclick motion) or mounted within an enclosure, for example a manual call point. It is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables and to report the status to Apollo compatible analog control equipment. Designed for use where space is limited Features a short circuit isolator as standard Interrupt/non interrupt in one unit Prealarm status available LED status indication (Yellow Fault, Green Polling, Red Alarm) DIN Rail mountable

42 VF5662 Switch Monitor Module The VF5662 Switch Monitor Module is designed to monitor the state of one or more single pole, volt free contacts connected and to report the status to Apollo compatible analog control equipment. Three input states normal, Fault, and alarm Visible LED Loop powered VF5663 Priority Switch Monitor Module The Priority Switch Monitor Module is designed to monitor the state of one or more single pole, volt free contacts and to report the status to Apollo compatible analog control equipment. It can also place a signal on the loop to provide early warning if a device such as a pull station is operated. Three input states normal, Fault, and alarm Loop powered Fast response time Interrupt facility Mounts on a 2gang or 4x4 box VF5664 Dual Priority Switch Monitor Module The VF5664 Dual Priority Switch Monitor Module contains two priority switch monitor modules ( ) on a single plate. Loop powered Fast response time Interrupt facility Mounts on a 2gang or 4x4 box Two visible LEDs VF5665 Switch Monitor Input/Output Module The Switch Monitor Input/Output Module provides a voltage free, single pole, changeover relay output, a single, monitored switch input and unmonitored, nonpolarized optocoupled input. It can report fault, switch open and switch closed levels Visible LED Fast Response time Mounts on a 2gang or 4x4 box VF5666 Sounder Control Module The Sounder Control Module monitors and controls the operation of a zone of conventional sounders and reports their status to the control panel. Allows sounders to be operated continuously or be pulsed, 1 second on, 1 second off May be synchronized when in pulsed operation Can also be used for public address speakers Visible LED VF5667 Relay Output Module Modules The Relay Output Module provides a single 2pole changeover relay. Loop Powered Can be placed anywhere on loop Visible LED

43 Horns & Strobes Standard Features Product Overview Model: VF Model: VF Sleek modern aesthetics Finger slide switches Voltage test points Multiple voltages 3 audible settings 90, 95, 99 db 8 Candela Settings Wall 15 / 1575 / 30 / 75 / 95 / 110 / 135 / 185 Ceiling 15 / 30 / 60 / 75 / 95 / 115 / 150 / 177 Universal mounting base Ceiling and wall mounts to 5 backbox types Environmentally friendly Low current draw Compatible with UL Regulated Voltage using filtered DC or unfiltered VRMS input voltage The VES series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The VES series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 db). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. Model: VF Model: VF The VES series of notification appliances feature a snapon base that is designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate mounting base can be prewired so circuit wiring can be fully tested before the appliance is installed and the surface is finished. Once the surrounding work is complete, the appliance can be simply installed by snapping it on to the base. Resettable shorting contacts in the base, which provide continuity for circuit testing, are opened when the appliance is installed. Any removal of the appliance will indicate a trouble condition on that circuit at the control panel that supervises the circuit. The same base is used for all VES series appliances to provide consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation.

44 Technical Specifications & Ordering Codes Model Type Strobe Candela Shape Color Current Draw 24 VDC Mounting VF Horn Strobe 15 / 1575 / 30 / 75 / 95 / 110 / 135 / 185 Square Red UMB * VF Horn Strobe 15 / 1575 / 30 / 75 / 95 / 110 / 135 / 185 Square White UMB * VF Horn Strobe 15 / 30 / 60 / 75 / 95 / 115 / 150 / 177 Round Red UMB * VF Horn Strobe 15 / 30 / 60 / 75 / 95 / 115 / 150 / 177 Round White UMB * VF Strobe 15 / 1575 / 30 / 75 / 95 / 110 / 135 / 185 Square Red UMB * VF Strobe 15 / 1575 / 30 / 75 / 95 / 110 / 135 / 185 Square White UMB * VF Strobe 15 / 30 / 60 / 75 / 95 / 115 / 150 / 177 Round Red UMB * VF Strobe 15 / 30 / 60 / 75 / 95 / 115 / 150 / 177 Round White UMB * VF Horn Square Red UMB * VF Horn Square White UMB * VF Horn Round Red UMB * VF Horn Round White UMB * General Notes * UMB = Universal Mounting Base. 1 Gang, 2 Gang, 4 square, 3.5 octal boxes Strobes are designed to flash at 1 flash per second minimum over their Regulated Voltage Range. All candela ratings represent minimum effective strobe intensity based on UL Standard Strobes are designed to operate under UL Standards 1971 and 464 for indoor use with a temperature range of 32 F to 120 F (0 C to 49 C) and maximum humidity of 85% (± 2%) UL 464 (UL 1971). Horns are designed to operate under UL Standard 464 for audible signal appliances (Indoor use only). Regulated Voltage Range is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology Listed Voltage Range. Voltage test points for quick troubleshooting and easy spot checking 8 candela settings Common base for wall and ceiling with 5 mounting options

45 REFER TO MODEMDACT ETHERNET INSTALLATION MANUAL WITH RELEASING VF162800, Rev. E02. AND MODEMDACT CONFIGURATION AND REPAIR MANUAL VF162400, Rev.E AFD0002FB MAIMUM POWER REQUIREMENT: ma FOR INDOOR DRY USE ONLY JACK J5 ETHERNET IS UNSUPERVISED AND POWER LIMITED JACK 1 TELCO LINE 1 AND LINE 2 ARE SUPERVISED THIS DEVICE COMPLIES WITH PART 68 RULES FCC REG. NO.: VESAL00BVF10xxxx REN = 00B JACK TYPE: RJ11C SIGNALING FIRE ALARM SUBASSEMBLY 3PBS LISTED LBL TESTED TO COMPLY WITH FCC STANDARDS THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. Industry Canada Electromagnetic Compatibility, ICES003: THIS CLASS A DIGITAL APPARATUS COMPLIES WITH CANADIAN ICES003. CET APPAREIL NUMERIQUE DE LA CLASSE A EST CONFORME A LA NORME NMB003 DU CANADA. REFER TO MEDIA GATEWAY INSTALLATION MANUAL WITH RELEASING VF Rev. E AFD0002FB MODEL NO.: VF MEDIA GATEWAY WITH RELEASING SIGNALING FIRE ALARM SUBASSEMBLY 3PBS LISTED LBL MAIMUM POWER REQUIREMENT: 115mA FOR INDOOR DRY USE ONLY JACK J3 VESNet IS SUPERVISED AND POWER LIMITED JACK J5 ETHERNET IS UNSUPERVISED AND POWER LIMITED THE MEDIA GATEWAY WITH RELEASING CONTAINS A DACT AT JACK 1 TELCO LINE 1 AND LINE 2. JACK 1 TELCO LINE 1 AND LINE 2 ARE SUPERVISED TESTED TO COMPLY WITH FCC STANDARDS THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. Industry Canada Electromagnetic Compatibility, ICES003: THIS CLASS A DIGITAL APPARATUS COMPLIES WITH CANADIAN ICES003. CET APPAREIL NUMERIQUE DE LA CLASSE A EST CONFORME A LA NORME NMB003 DU CANADA. THIS DEVICE COMPLIES WITH PART 68 RULES FCC REG. NO.: VESAL00BVF10xxxx REN = 00B JACK TYPE: RJ11C REFER TO NETWORK INTERFACE CARD (NIC) INSTALLATION MANUAL WITH RELEASING VF Rev. E AFD0002FB SIGNALING FIRE ALARM SUBASSEMBLY 3PBS LISTED LBL MAIMUM POWER REQUIREMENT: ma FOR INDOOR DRY USE ONLY JACK J3 VESNet IS SUPERVISED AND POWER LIMITED THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. Industry Canada Electromagnetic Compatibility, ICES003: THIS CLASS A DIGITAL APPARATUS COMPLIES WITH CANADIAN ICES003. CET APPAREIL NUMERIQUE DE LA CLASSE A EST CONFORME A LA NORME NMB003 DU CANADA. THIS DEVICE COMPLIES WITH PART 68 RULES FCC REG. NO.: VESAL00BVF10xxxx REN = 00B JACK TYPE: RJ11C VESNet Communication and Network Options A B VESNET Ethernet Heartbeat POWER J8 VNet A VNet B Comm Active Comm Fault TELCO PRI SEC Line 1 Line 2 J7 DATA VES, LLC 620 ALLENDALE ROAD, SUITE 175 KING OF PRUSSIA, PA PN: HW REV E VF1150 Media Gateway with Releasing Supports networking, remote monitoring, virtual display and remote programming and remote displays. A B VESNET Heartbeat POWER J8 VNet A VNet B Comm Active Comm Fault J7 DATA VF1151 Network Interface Card (NIC) with Releasing Used for interpanel networking and interfaces to other systems. VES, LLC 620 ALLENDALE ROAD, SUITE 175 KING OF PRUSSIA, PA MODEL NO.: VF NETWORK INTERFACE CARD (NIC) WITH RELEASING Heartbeat POWER J8 PN: HW REV E Ethernet VNet A VNet B Comm Active Comm Fault DATA J7 VES, LLC 620 ALLENDALE ROAD, SUITE 175 KING OF PRUSSIA, PA MODEL NO.: VF MODEMDACT ETHERNET WITH RELEASING TELCO PRI SEC Line 1 Line 2 PN: HW REV E VF1153 VESNet Ether/DACT Used for single panel installations. Supports remote monitoring, virtual display, and remote programming. Communications Installation One Communications Card per Panel 1 Plugin Ribbon Cable, 2 CAT5 wired to RJ45 VESNet connectors 2 RJ11 Telephone Jacks 1 RS232 cable to panel Ethernet RJ45 on Media Gateway Powered from Panel VESNet communication is only available on the Media Gateway and NIC. Telephone jacks are only available on the Media Gateway and Ether/DACT. Standard Features Dualline digital communicator with line seizure on Media Gateway and Modem DACT 33.6 Kbps modem for panel downloading Provides networkwide programming with remote and local management Remote programming via esp Discovery Transmits in SIA (SIA 8 and SIA 20) Digital Communications standard (300 bps) and Contact ID communication format All nodes report through a single Media Gateway to a central station and data center VESNet configurable for Class A or B networking Communication speed of 115 Kbps on VESNet and 10BaseT Ethernet interface Builtin Firewall with messaging through LAN connections always from within VESNet Maintenance message logging Virtual Panel ready with Media Gateway Builtin Web Server in the Media Gateway for displaying Virtual Panel Installation diagnostics at startup through esp Onboard Motorola 32 bit, 66 MHz RISC processor RJ45 (Ethernet) port for LAN connection 2 RJ45 VESNet ports for network connections using standard CAT 3,5,5e,6 cable 2 RJ11 Telco ports for phone lines for connection to RJ31 or RJ38 Up to 126 Fire Nodes can be installed on VESNet Up to 2,000 feet between nodes on VESNet Installation diagnostics at startup

46 Added Features: VF1221 Elite with Media Gateway : All the features of the Modem/DACT and NIC: plus Virtual Panel ready with Firewall Enables network programming with direct TCP/IP access to each panel Access point for network communications VF1222 Elite with NIC: Network uses standard Cat 5 cabling Up to 2,000 ft. between adjacent panels 115 Kbps constant network speed TCP and UDP communications through VESNet Total network delay less than 3 sec. with 127 panels Network jacks RJ45 (VESNet and Ethernet) Mapped Network; Display messages for Any or All nodes VF1224 Elite with VESNet Ether/DACT: Virtual Panel ready with Firewall Direct IP programming with esp Discovery Transfer agent Access point for network communications Dual line digital communicator and modem Central Station reporting; SIA and Contact ID Phone line jacks RJ11 (two) Modem speed: 33.6 Kbps for program downloading Technical Specifications DC Input: 24 VDC on all Com Power: Standby current Media Gateway NIC Ether/DACT 100mA 75mA 75mA 115mA 80mA 95mA Dimensions: 2.5 W x 7.5 D x H (includes circuit board with cover) Operating Environment: Low temperature High temperature Relative humidity 32 +/ 3 F (0 +/ 2 C), UL 864, / 3 F (49 +/ 2 C), UL 864, % +/ 90 +/ 3 F (32 +/ 2 C), UL 864, 65.4 Virtual panel capability The VES Elite Panels with a Media Gateway can be connected to a local IT LAN and provides the ability to view a depiction of the FACP display. Virtual Panel may also allow operating the keypad, as if standing in front of the FACP. Can be viewed by all personnel with the correct security logon Presents an exact replica of messages on any connected Elite panel s display Authorized personnel with panel security access can also perform all display keypad functions from Virtual Panel locations. Virtual Panel ships disabled and requires activation Alarm current Internet Explorer 5.5 or higher is required on the desktop PC using Virtual Panel Note: The Energy conversion equipment (ECE) shall be designed to function in an atmosphere having a relative humidity that can vary from 5 percent to 95 percent, noncondensing. NFPA 111, 5.2.7

47 VF Channel Input/Output Board VF Channel Input/Output Board A powerful addition to the Elite system. For LED mimics, plant alarms, plant control, voice evacuation and many other applications. Technical Specifications Supply voltage: 21 30V DC Quiescent current consumption: 20mA Current per input: 3mA (maximum) Current per output: 100mA (maximum) Communications: RS485 two wire Max. distance from panel: 3900 feet (using correct type of cable) PCB size: 7.5 H x 2.4 W Cable capacity: 2.5mm per terminal Operating temperature: 14º F to 122º F ( 10º C to 50º C) Operating humidity: to 95% (non condensing) Standard Features UL approved 16 channels Each channel configurable as input or output Inputs optoisolated Outputs open collector transistor Simple 2 wire connection to control panel Up to 32 boards supported per panel (512 Input/Output Channels) Inputs and outputs configurable as per field devices Full cause and effects on all inputs and outputs Multi drop RS485 communications Can be used with other Elite I/O modules on the same panel Compatible with Elite RS panels Product Overview To add more I/O capablity to the extensive options already offered by the Elite control panel, up to thirty two, sixteen channel I/O boards may be connected. When using a simple two wire RS485 communications protocol, these boards may be mounted locally to the control panel or distibuted on a bus up to 3,900 feet long by using a suitable cable. The flexibility of these boards is further enhanced by the fact that each of the channels is configurable as either an input or and output. Each channel may also be configured to produce a variety of input actions or respond to a varierty of output types. All channels can contribute to, or respond to, system wide cause and effects logic. Typical uses for I/O boards include geographical LED mimic displays and plant alarm inputs. Standard Elite control panels contain fixings for one I/O board, which can easily be connected using four small signal wires to the power and comms bus within the panel. Consideration must be taken as to the loading on the main panel.

48 VF071x Fire Document Enclosure Standard Features Matches design & color scheme for standard Elite control panel ranges Easy to install Key Lockable Designed for versatility Choice of small or large capacity enclosure Product Overview Another addition to the VES range, the document box is designed to complement the design & color of the Elite range of control panels. The standard version Document Box will hold up to 50 A4 sheets of information on the Fire Detection or other security systems within a premises. The deep version will hold up to 100 sheets. The Doc Box also doubles up as a Key Box providing 7 easily accessible formed key hooks inside the enclosure. Available in Gray Panel Options VF0710xx: Standard VF0711xx: Deep VF0712xx: Standard w/ Tamper VF0713xx: Deep w/ Tamper xx = 10 (Red) or 40 (Gray) Technical Specifications Construction: 18AWG sheet steel Dimensions: VF0711 / VF0713: 14.5 W x 12.2 H x 3.4 D VF0710 / VF0712: 14.5 W x 12.2 H x 2.5 D Weight: 6.6lb Finish (lid & box): RAL3002 (Red) or BS 00 A 05 (Gray) Finish (product labels): BS 00 A 05 (Gray) VF4683 Manual Call Point Standard Features Flashing LED option Plug and play terminal connections for fast wiring Allow wiring continuity testing before fitting Reports an alarm in under 0.2 seconds Overview The Discovery Manual Call Point is compliant with EN5411. The Call Point can be addressed at the commissioning stage by means of a sevensegment DIL switch. When operated, the manual call point interrupts the polling cycle for a fast response. Resettable element

49 VF073x Ancillary Enclosure Standard Features Matches design & color scheme for standard Elite control panel ranges Easy to install Key Lockable Designed for versatility Three sizes of enclosure to choose from Product Overview The Ancillary enclosure is designed to provide an organized and secure mounting enclosure for I/O cards and SLC devices. The Ancillary enclosure is manufactured in three different sizes, two different colors and with a tamper option. The Ancillary Enclosure is customized with mounting requirements and multiple conduit entries to fit module configurations depicted in the table below. Technical Specifications Construction: VF073x: 18AWG sheet steel VF073x: 16AWG sheet steel VF073x: 16AWG sheet steel Dimensions: VF0730: 14.5 W x 12.2 H x 3.4 D VF0731: 14.5 W x 18.9 H x 4.25 D VF0732: 14.5 W x 24 H x 5 D Finish (lid & box): RAL3002 (Red) or BS 00 A 05 (Gray) Finish (product labels): BS 00 A 05 (Gray) Panel Options (Modules must be purchased separately) Part No. Enclosure Size I/O Modules SLC Modules 14.5 W x 12.2 H x 3.4 D 0 2 VF0730xx* 14.5 W x 12.2 H x 3.4 D W x 12.2 H x 3.4 D W x 18.9 H x 4.25 D 0 6 VF0731xx* 14.5 W x 18.9 H x 4.25 D W x 18.9 H x 4.25 D W x 18.9 H x 4.25 D W x 24 H x 5 D W x 24 H x 5 D 1 6 VF0732xx* 14.5 W x 24 H x 5 D W x 24 H x 5 D W x 24 H x 5 D 4 0 * xx = 10 (Red) or 40 (Gray)

50

51 VoiceAlert Voice Evacuation System VF9700 Master Panel VF9755 Distributed Panel Voice Alert Panel Options VF9520 Mother Board VF9521 Fire Phone Input Card VF9522 Fire Phone Output Card VF9524 Warden Station VF9535 Extended Input Interface VF9558 Class A Return Module VF9720 Master Panel, 16 Zone, Red VF9722 Master Panel, 32 Zone, Red VF9724 Master Panel, 48 Zone, Red VF9726 Master Panel, 64 Zone, Red VF9728 Master Panel, 80 Zone, Red VF9730 Master Panel, 96 Zone, Red VF9740 Master Panel, 16 Zone, w/phone, Red VF9742 Master Panel, 32 Zone, w/phone, Red VF9744 Master Panel, 48 Zone, w/phone, Red VF9746 Master Panel, 64 Zone, w/phone, Red VF9748 Master Panel, 80 Zone, w/phone, Red VF9750 Master Panel, 96 Zone, w/phone, Red VF9760 Distributed Panel, Single, 25W, Red VF9762 Distributed Panel, Single, 50W, Red VF9764 Distributed Panel, Single, 100W, Red VF9768 Distributed Panel, Single, 50W, w/phone, Red VF9770 Distributed Panel, Single, 100W, w/phone, Red VF9774 Distributed Panel, Dual, 50W, Red VF9776 Distributed Panel, Dual, 100W, Red VF9778 Distributed Panel, Single, 25W, w/phone, Red VF9780 Distributed Panel, Dual, 50W, w/phone, Red VF9782 Distributed Panel, Dual, 100W, w/phone, Red VF9793 Distributed Panel, Dual, 200W, w/phone, Red VF4405 Speaker, Wall Red VF4409 Speaker Ceiling 2 Watt Red Standard Features True Multiplex 6 Channel Distributed Audio Integrated Fire Phone, Area of Rescue and Fan & Damper Control capability Modular System components added as needed Integrated 2 Channel Digital Message Repeater Live Microphone Page to any zone Fast RS485 Communication Protocol Easy Installation and Operation Natural Sound Voice Recordings Built in Alarm and Alert Signals Up to 4 Minute Message Capacity Works with 12VDC or 24VDC Fire Alarm Panel Listed with for use with the Elite FACP 3 Minute Message Restart on Microphone Key Fully Supervised Operation Basic System includes Master Panel (VF9700) Master Mic Control 16 switch control points Dual Channel DMR High speed communication loop Distributed Panel (VF9755)* 4 Output Zones (may be configured for 8) Dual Channel Audio Interface Dual Channel Amplification Optional Integrated Fire Phone AreaofRescue Fan and Damper system control Maximum System Configuration Up to 256 Distributed Panels (VF9755) Up to 2028 monitor and control points *Number of distributed panels to be determined by building specifications Product Overview The VES VoiceAlert High Rise Evacuation System operates in conjunction with the Elite Fire Alarm Control Panel (FACP) in a building to provide automatic response to life safety emergencies. The VoiceAlert system includes all necessary features to provide an effective voice evacuation system. The VoiceAlert can be custom configured to satisfy the needs of any high rise application. Fire department authorities can easily take command of evacuation or relocation procedures and emergencies. Building management and fire brigades can monitor and control emergency response even before the professionals arrive. The VoiceAlert system includes capacity for 6 Channels of simultaneous audio. This provides for evacuation, stayinplace, or other public address announcements and automatic messages. Fire Fighter Phones or Warden Stations may be included as required. Areaof Rescue stations can reassure handicapped occupants that help is on the way. Smoke control, stair pressurization, and HVAC shutdown can be completely automatic, unless controlled manually by management or fire authorities. Military Emergency VoiceAlert Systems DOD Compliant The U.S. Department of Defense is requiring mass notification systems in inhabited buildings. The ability to quickly broadcast prerecorded and live warnings to all personnel is considered essential in reducing casualties in the event of attack on DOD facilities. The VoiceAlert VM supervised emergency voice alert system meets or exceeds DOD Minimum Antiterrorism Standards for Buildings, UFC It is also compliant with UFC , Design and O & M Mass Notification Systems.

52 VoiceAlert Voice Evacuation System Components VF9315 Audio Module Interface Controls two VF9212/9236/9256 amplifier modules in remote distribution panels. One required when adding back up amplification to a Dual channel system. Uses an addition slot on a VF9227. VF9316 Audio System Control Provides digitally stored Message Control. Has two RS232 com ports. VF9546 Backup Amplifier switching relay One required for each Distributed Amp when automatic switching / redundant amplification is needed. On a single Channel system the back up amplifier can be located in any 9755 Series panel. On a Dual Channel system an additional VF9315 card, and Amplifier assembly is required (the # represents the largest power amplifier in the system 25/50/100). VF9547 Backup Amplifier switching relay Class A One required for each Distributed Amp plus the spare amplifier when automatic switching / redundant amplification is needed Class A wiring. On a single Channel system the spare amplifier can be located in any 9755 Series panel. On a Dual Channel system an additional VF9315 card, and Amplifier assembly is required (the # represents the largest power amplifier in the system 25/50/100). VF9525 Break Out Card Used to provide terminal connections from 10 Pin ribbon cable for wiring termination. (2 required) Needed when Dual Channel BackUp Amplification is required. VF9545 Data Communications Controller A VF9545 is located in the Master Panel and each Distributed Panel the VF9545 is the connection point for the NETCOMM communications. The Data loop must be wired style 6 or 7 (Style 7 preferred) (must have return data loop). Replacement Card, typically preprogrammed from the factory. VF9537 Fiber Optic Transceiver Provides termination for Fiber Optic communications between the Master Panel and the Distributed Panels. VF9548 Fiber Optic Style 7 card Master Panel Fiber Optic card (1 per system) required when Style 7 Fiber Optic communications is used. The VF9548 card converts the secondary (style 7) data loop to a data signal that can be sent on the Fiber Optic secondary loop. VF9521 Fire Phone Interface Provides 4 supervised Class B Fire Phone circuits in distributed panel (4max 16 circuits). When more then one is used in a 9755 Series panel a VF9522 card is required for each. VF9522 Fire Phone Output Adapter Extra terminal card that must be used with the 2nd, 3rd & 4th VF9521 cards in a 9755 Series panel. VF9549 Fire Phone Output Adapter Extra break out card that must be used with the 2ND, 3RD & 4TH MFPI cards in a 9755 Series panel. This card aligns all 4 Fire Phone circuits vertically. VF9318 Fire Phone Relay Warden station reverse polarity relay for NYC applications. VF9541 Isolated Network Bridge Network interface when a Master Panel is needed to communicate with remote Master Panels running their own systems. VF9315 VF9546 VF9545 VF9549 VF9547 VF9537 VF9521 VF9316 VF9525 VF9548 VF9522 VF9318 VF9526 VF9541 VF9526 Input Interface Card Hardwired conventional control input interface/trigger. Required when using any triggers other the VES Intelligent Interface. Provides 16 inputs and control for up to 7 additional input cards (128 inputs). System capacity for up to 16 VF9526cards (2048 inputs). TTL or dry contract input. Also accepts a reverse polarity NAC circuit trigger.

53 Description Fire Phone accessories give the VM system twoway communication capability. Fire Phone jacks are mounted on a single gang plate. Fixed telephone and warden stations are available in surface / semiflush mount cabinet with a thumbturnlatch. VF9512 Ordering Information Model Number Description VF9512 VF9511 VF9510 VF9514 VF9517 Telephone Jack Brushed Stainless Steel Single Gang Plate Portable Handset Color Red (6 mount in VF9510 cabinet) Telephone Cabinet Holds 6 VF511 Portable Handset Cabinet: Charcoal Gray std. 10 Red (Surface / SemiFlush Mount / Key Lock 27 x 141/2 x 4 hwd) Fire Phone Station Coil cord / Thumb Turn Latch Cabinet: Red (Surface / SemiFlush Mount 123/4 x 71/4 x 33/4 hwd) Warden Station Armored cable / Thumb Turn Latch Cabinet: Red (Surface / SemiFlush Mount 123/4 x 71/4 x 33/4 hwd) VF9510 VF9511 VF9514 VF9517

54

55 Operation Master Panel Application Fire Phone Station Distributed Panel Fire Phone Jack The VES VoiceAlert High Rise Evacuation System operates in conjunction with the Elite Fire Alarm Control Panel (FACP) in a building to provide automatic response to life safety emergencies. The VoiceAlert system includes all necessary features to provide an effective voice evacuation system. The VoiceAlert can be custom configured to satisfy the needs of any high rise application. Fire department authorities can easily take command of evacuation or relocation procedures and emergencies. Building management and fire brigades can monitor and control emergency response even before the professionals arrive. The VoiceAlert system includes capacity for 6 Channels of simultaneous audio. This provides for evacuation, stayinplace, or other public address announcements and automatic messages. Fire Fighter Phones or Warden Stations may be included as required. AreaofRescue stations can reassure handicapped occupants that help is on the way. Smoke control, stair pressurization, and HVAC shutdown can be completely automatic, unless controlled manually by management or fire authorities. Basic System Master Panel (VoiceAlert) Master Mic Control 16 switch control points Dual Channel DMR High speed communication loop Distributed Panel 4 Output Zones (may be configured for 8) Dual Channel Audio Interface Dual Channel Amplification Optional Integrated Fire Phone AreaofRescue Fan and Damper system control Number of distributed panels to be determined by building specifications Maximum System Configuration Up to 256 Distributed Panels Up to 2028 monitor and control points Standard Features True Multiplex 6 Channel Distributed Audio Integrated Fire Phone, Area of Rescue and Fan & Damper Control capability Modular System components added as needed Integrated 2 Channel Digital Message Repeater Live Microphone Page to any zone Fast RS485 Communication Protocol Easy Installation and Operation Natural Sound Voice Recordings Built in Alarm and Alert Signals Up to 4 Minute Message Capacity Works with 12VDC or 24VDC Fire Alarm Panel Listed with for use with the Elite FACP 3 Minute Message Restart on Microphone Key Fully Supervised

56 System Diagram Basic System Configuration Basic System Master Panel Master Mic 16 Switch Control Module Dual Channel DMR High Speed Communications Loop Distributed Panels 4 Output Zones Dual Channel Audio Interface Dual Channel Amplification Optional Intergrated Fire Phone Areaof Refuge Fan and Damper System Control

57 VF9220 VoiceAlert Voice Evacuation System Features Clean Deadfront Construction Digitally Recorded Automatic Evacuation Message (Up to 4 Minutes of Message Capacity) 50 Watt High Efficiency Digital Amplifier 25 or 70 VRMS Field Selectable 120 VAC Power Supply and Battery Charger Live Microphone Override of Message and Tone Analog Addressable Compatible High Reliability, No Maintenance, Fully Supervised Easy Installation and Operation Natural Sound Recordings Built in Alarm and Alert Signals Up to 4 Minute Message Capacity Works with 12VDC or 24VDC Fire Alarm Panels Works with Analog/Addressable and Microprocessor based Fire Alarm Panels. 3 Minute Message Restart on Microphone Key 24 Hour Backup with two 12V 7AHr Batteries Description The VF9220 Voice Evacuation System provides 50 Watts of speaker power. The VF9220 includes all necessary features to provide an effective voice evacuation system. With the addition of zone splitters, remote microphone panels and expander modules, the VF9220 can be custom configured to satisfy the needs of most applications. The VoiceAlert 50 has its own power supply and battery charger. Panel must be wired with 120VAC and standby batteries connected. A digital message repeater (DMR) is built into the VF9220. The selection of alarm tone and automatic message repeats, as well as the 6 Hour delay of the AC power failure reporting feature are all field configurable. The paging microphone is an integral component. Trouble condition which will be reported locally, as well as through the FACP. Model Number Description VF9220 VF9221 VF9222 VF9223 VF W Voice Evacuation System with Power Supply / Battery Charger Paging Microphone 50W Voice Evacuation System with 4 Speaker Zones 50W Voice Evacuation System with 8 Speaker Zones 50W Voice Evacuation System with 12 Speaker Zones 50W Voice Evacuation System with 16 Speaker Zones

58 Technical Characteristic Engineers Specifications (Continued) The voice evacuation message/signal shall be broadcast until the Fire Alarm Control Panel (FACP) is reset, or until fire emergency personnel interrupt the broadcast with a manual page. On reset system shall automatically return to standby (normal operating) condition. Engineers Specification The Voice Evacuation system shall be VES VF9220 or approved equal. The voice evacuation system shall provide 50 watts signal power and 50 watts voice power, and shall be UL listed. The voice evacuation system shall be microprocessor based, and shall contain an integral microphone, 50 watt audio amplifier, tone generator, digital message repeater, 120VAC power supply and battery charger. A secondary message shall be provided which can be triggered by the closure of a contact from either the FACP or from any normally open contact device. Remote paging microphone (s) will be supported by the system through a supervised circuit. Remote microphone may be mounted up to 5,000 feet away from the voice evacuation panel.

59 VF9240 VoiceAlert Voice Evacuation System Features Clean Deadfront Construction Digitally Recorded Automatic Evacuation Message (Up to 4 Minutes of Message Capacity) 100 Watt High Efficiency Digital Amplifier 25 or 70 VRMS Field Selectable 120 VAC Power Supply and Battery Charger Live Microphone Override of Message and Tone Analog Addressable Compatible High Reliability, No Maintenance, Fully Supervised Easy Installation and Operation Natural Sound Recordings Built in Alarm and Alert Signals Up to 4 Minute Message Capacity Works with 12VDC or 24VDC Fire Alarm Panels Works with Analog/Addressable and Microprocessor based Fire Alarm Panels. 3 Minute Message Restart on Microphone Key 24 Hour Backup with two 12V 7AHr Batteries Made in the USA. VF9240 shown with keylockdoor removed Description The VF9240 Voice Evacuation System provides 100 Watts of speaker power. The VF9240 includes all necessary features to provide an effective voice evacuation system. With the addition of zone splitters, remote microphone panels and expander modules, VF9240 can be custom configured to satisfy the needs of most applications. The VF9240 has its own power supply and battery charger. Panel must be wired with 120VAC and standby batteries connected. A digital message repeater (DMR) is built into the VF9240. The selection of alarm tone and automatic message repeats, as well as the 6 Hour delay of the AC power failure reporting feature are all field configurable. The paging microphone is an integral component. Trouble condition which will be reported locally, as well as through the FACP. Model Number Description VF9240 VF9241 VF9242 VF W Voice Evacuation System with Power Supply / Battery Charger Paging Microphone Digital Message Repeater 100W Voice Evacuation System with 4 Speaker Zones 100W Voice Evacuation System with 8 Speaker Zones 100W Voice Evacuation System with 12 Speaker Zones in a Large Cabinet 14.5 x 27 x 4 w*h*d* VF W Voice Evacuation System with 16 Speaker Zones in a Large Cabinet 14.5 x 27 x 4 w*h*d* Color VF10 for Red and VF 20 for Charcoal

60 Technical Characteristic Engineers Specifications (Continued) The voice evacuation message/signal shall be broadcast until the Fire Alarm Control Panel (FACP) is reset, or until fire emergency personnel interrupt the broadcast with a manual page. On reset system shall automatically return to standby (normal operating) condition. Engineers Specification The Voice Evacuation system shall be VES VF9240 or approved equal. The voice evacuation system shall provide 100 watts signal power and 100 watts voice power, and shall be UL listed. All speaker circuits shall be field selectable for 25 or 70 Vrms and shall be power limited. A secondary message shall be provided which can be triggered by the closure of a contact from either the FACP or from any normally open contact device. Remote paging microphone (s) will be supported by the system through a supervised circuit. Remote microphone (s) may be mounted up to 5,000 feet away from the voice evacuation panel. The voice evacuation system shall be microprocessor based, and shall contain an integral microphone, 100 watt audio amplifier, tone generator, digital message repeater, 120VAC power supply and battery charger.

61 VF9260 and VF9280 VoiceAlert Voice Evacuation System Features Deadfront Construction Digitally Recorded Automatic Evacuation Message (Up to 4 Minutes of Message Capacity) 50/100 Watt BulletProof Amplifier 25 or 70 VRMS Field Selectable 120 VAC Power Supply and Battery Charger Live Microphone Override of Message and Tone Analog Addressable Compatible High Reliability, No Maintenance, Fully Supervised Easy Installation and Operation Natural Sound Recordings Built in Alarm and Alert Signals Up to 4 Minute Message Capacity Works with 12VDC or 24VDC Fire Alarm Panel Works with Analog/Addressable and Microprocessor based Fire Alarm Panels. Description The VF9260 / VF9280panels provide 200W and 150W of speaker power respectively. Speaker zones can be configured for general alarm or alarm by zone operation as required. The VoiceAlert device above is shown with the keylockdoor removed. Digital message repeater, microphone, 120 VAC power supply and battery charger are all built in. VoiceAlert voice evacuation panels can be configured for Churches, Restaurants, Movie Theaters, Auditoriums and High Rise buildings. The VF9260 / VF9280 panels are an attractive surface or semiflush mounted back boxes, with a hinged and key locked door. Model Number Description VF W Voice Evacuation System with 2 Speaker Circuits 1 100W 1 50W Power Supply / Battery Charger Paging Microphone Digital Message Repeater VF W Voice Evacuation System with 8 Speaker Zones 100W / 4Z 50W / 4Z VF W Voice Evacuation System with 12 Speaker Zones 100W / 8Z 50W / 4Z VF W Voice Evacuation System with 16 Speaker Zones 100W/8Z 50W/8Z Model Number Description VF W Voice Evacuation System with 2 Speaker Circuits 100W each Power Supply / Battery Charger Paging Microphone Digital Message Repeater VF W Voice Evacuation System with 8 Speaker Zones 100W / 4Z 100W / 4Z VF9282 VF W Voice Evacuation System with 12 Speaker Zones 100W / 8Z 100W / 4Z 200W Voice Evacuation System with 16 Speaker Zones 100W / 8Z 100W / 8Z Color VF10 for Red, VF20 for charcoal

62 Technical Characteristic 100W VoiceAlert Module Primary Power 2A 24 VDC Battery Power Standby 0.18A Alarm 2.5A Output 50W VoiceAlert Module /70 VRMS Tone and Voice Primary Power 2A 24 VDC Battery Power Standby 0.13A Alarm 1.0A Output Backbox Dim Color 50 25/70 VRMS Tone and Voice 14.5 x 27 x 4 w h d Charcoal Grey std Red optional The specifications listed above are provided per module. Engineers Specification The Voice Evacuation system shall be VES or approved equal. The voice evacuation system shall provide 100 watts signal power and 100 watts voice power, and shall be UL listed. All speaker circuits shall be field selectable for 25 or 70 Vrms and shall be power limited. The voice evacuation system shall provide 200 / 150 Watts of signal and voice power, and shall be UL listed. All speaker circuits shall be field selectable for 25 or 70 Vrms operation and shall be power limited. The voice evacuation system shall be microprocessor based, and shall contain an integral microphone, audio amplifier, tone generator and digital message repeater. A 120 VAC Power Supply and battery charger for standby batteries shall be included. The voice evacuation message/signal shall be broadcast until the FACP is reset, or until fire emergency personnel interrupt the broadcast with a manual page. Remote paging microphone will be supported through a supervised circuit.

63 Speaker and Speaker Strobes Wall Mounted Speakers and Speaker Strobes General Notes Strobes are designed to flash at 1 flash per second minimum over their Regulated Voltage Range. Note that NFPA72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32 F to 120 F (0 C to 49 C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). Regulated Voltage Range is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology Listed Voltage Range. Table1: Average RMS Current Wall mounted Strobe Current Wall Mount Speaker W 24MCW 24MCWH Strobes 15cd 15cd 30cd 75cd 110cd 135cd 185cd 24 vdc UL max* *RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (1633v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For unfiltered FWR ratings, see installation instructions. Standard Features Approvals include: UL Standard 1971, UL Standard 1480, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM) and Chicago (BFP). See approvals by model in Specifications and Ordering Information ADA/NFPA/ANSI compliant Complies with OSHA 29 Part Wall mount speaker strobe models with field selectable candela settings of 15/30/75/110cd or 135/185cd (MultiCandela models), or 1575cd (Single Candela model) Field selectable taps for 25 or 70 VRMS operation from 1/8 watt up to 2 watts High efficiency design for maximum output at minimum wattage across a frequency range of 400 to 4000 HZ 24 VDC strobes produce 1 flash per second with wide UL Regulated Voltage of 16 to 33 volts using filtered DC or unfiltered VRMS input voltage PS12/248CP and PS12/248MP Power Supply with builtin sync protocol Mount to 4 square x 21/8 deep backbox with no extension ring required Snap on grille cover with no visible mounting screws Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires Product Overview The VES Series of wall mounted Speakers and Speaker Strobes feature high efficiency sound output, with dual voltage (25/70 VRMS) capability and field selectable taps from 1/8 to 2 watts. They are designed to provide a sleek, aesthetic appearance for emergency voice/alarm communications systems. All speakers and speaker strobe models mount to standard 4 x 21/8 electrical boxes (with no extension ring required) and incorporate a speaker mounting plate for faster installation. The grille cover snaps on so no mounting screws are visible. Attractive surface boxes are also available for surface installations. The wall mounted Speaker Strobe models use VES low current draw Series RSS strobes for wall mounted applications. Strobe options include patented MCW multicandela strobes with field selectable candela settings of 15/30/75/110 cd or high intensity MCWH strobes with field selectable 135/185 candela. Models with 1575 candela (75 cd on axis) are also offered. These Speakers and Speaker Strobes provide high audio output with clear audibility and are designed to meet the critical needs of the life safety industry for effective emergency voice communications, tone signaling and visible signaling to alert the hearing impaired. The strobe portion of all wall mounted Speaker Strobes may be synchronized when used in conjunction with the VES Sync Modules or the VES PS248MC Power Supply with Patented Sync Protocol. VES Series synchronized strobes offer an easy way to comply with ADA and NFPA regulations concerning photosensitive epilepsy. The wall mounted Speaker Strobes are UL Listed for indoor use under Standard 1971 (Signaling Devices for the HearingImpaired) and Standard 1480 (Speaker Appliances). All inputs employ IN/OUT wiring terminals for fast installation using #12 to #18 AWG wiring and are compatible with FACP line supervision. Color options for the wall mounted Speakers and Speaker Strobes are red or offwhite. Table2: VF4405 UL Reverberant dba 10 Feet** Watts Wall mount Speaker Wall mount Speaker Strobe 1/ / **dba ratings are based on UL testing under UL standard /

64 WALL MOUNTED SPEAKER AND STROBE OPERATE INDEPENDENTLY (NONSYNC OR SYNC) FROM PRECEDING APPLIANCE OR VOICED EVACUATION PANEL FROM PRECEDING STROBE, SYN MODULE, POWER SUPPLY OR FACP STROBE + SPEAKER TO NET APPLIANCE OR EOLR TO NET STROBE OR EOLR WALL MOUNTED SPEAKER STROBE APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS A FACP STROBE NAC CIRCUIT OUT STROBE NAC CIRCUIT RETURN + SYNC + OUT 1 + IN 1 MINUS 1 + AUDIBLE MINUS 2 + IN 2 + OUT 2 WALL MOUNTED SPEAKER STROBES SYNCHRONIZED WITH MULTIPLE DSM MODULES F A C P Strobe NAC Cir. Strobe NAC Cir. Strobe NAC Cir. Sync + Sync + Sync + DSM Interconnecting wiring system shown. Maximum C twenty (20) Note: Figure shows interconnection to strobe through sync module. Speaker portion requires 2 separate conductors to communications system. WALL MOUNTED SPEAKER STROBE APPLIANCES & RSS STROBES SYNCHRONIZED WITH PS12/248CP and PS12/248MP F A C P Series PS12/24 8MP or PS12/248CP OUTPUTS 14 4CLASS B OR 2CLASS A Series PS12/24 8MP or PS12/24 8CP RSS RSS RSS EOLR Technical Specifications and Ordering Information Model Wall Ceiling Strobe Grill Flush Mount Mount Mount Candela Color Backbox Surface Mount Backbox Mounting Options Agency Approvals UL MEA CSFM FM BFP VF VF VF VF VF VF VF VF Red White 4 x 4 x 21/8 4 x 4 x 21/8 15 (75 on axis) Red 15 (75 on axis) White 4 x 4 x 21/8 4 x 4 x 21/8 15/30/75/110 15/30/75/ / /185 Red White Red White 4 x 4 x 21/8 4 x 4 x 21/8 4 x 4 x 21/8 4 x 4 x 21/8 VF VF VF VF VF VF VF VF E,O,P,Q,R,U,Y,AA E,O,P,Q,R,U,Y,AA E,Q,U,BB E,Q,U,BB E,Q,U,BB E,Q,U,BB E,Q,U,BB E,Q,U,BB Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with VES standard terms and conditions. * * * * * * * * * * * * * * * * * Pending Architects and Engineers Specifications The speaker appliances shall be VES Series Wall Mounted Speakers and the speaker strobe appliances shall be VES Series Wall Mounted Series Speaker Strobes or approved equals. The speakers shall be UL Listed under Standard 1480 for Fire Protective Service and speakers equipped with strobes shall be listed under UL Standard 1971 for Emergency Devices for the HearingImpaired. In addition, the strobes shall be certified to meet the requirements of FCC Part 15, Class B. All speakers shall be designed for a field selectable input of either 25 or 70 VRMS, with selectable power taps from 1/8 watt to 2 watts. All models shall have listed sound output of up to 89 dba at 10 feet and a listed frequency response of 400 to 4000 Hz. The speaker shall incorporate a sealed back construction. All inputs shall employ terminals that accept #12 to #18 AWG wire sizes. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall be of low current design. Where MultiCandela Speaker Strobes are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mounting. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela onaxis is required. When synchronization is required, the strobe portion of the appliance shall be compatible with the VES sync modules or VES PS248MC Power Supply with builtin Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a nonsynchronized flash rate. The speaker and speaker strobe appliances shall be designed for indoor flush mounting to 4 x 21/8 electrical boxes without need for an extension ring or surface mounting to VES VF4416 or VF4417 surface boxes. The speaker and speaker strobe shall incorporate a speaker mounting plate with a snapon grille cover. The finish of the VES Series Wall Mounted speakers and speakers strobes shall be white or red.

65 Speaker and Speaker Strobes Ceiling Mounted Speaker and Speaker Strobes General Notes Strobes are designed to flash at 1 flash per second minimum over their Regulated Voltage Range. Note that NFPA72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32 F to 120 F (0 C to 49 C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). Regulated Voltage Range is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology Listed Voltage Range. Table1: Average RMS Current Ceiling Strobe Current Ceiling Mount Mount Speaker 24MCC 24MCCH Strobes 15cd 30cd 75cd 110cd 135cd 185cd 24 vdc UL max* Standard Features Approvals include: UL Standard 1971, UL Standard 1480, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM) and Chicago (BFP) See approvals by model in Specifications and Ordering Information ADA/NFPA/ANSI compliant Complies with OSHA 29 Part Ceiling mount strobe models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd (Multicandela models) Strobes produce 1 flash per second over the regulated voltage range 24 VDC with wide UL Regulated Voltage using filtered DC or unfiltered VRMS input voltage Field selectable taps for 25 or 70 VRMS operation from 1/8 watt up to 2 watts High efficiency design for maximum output at minimum wattage across a frequency range of 400 to 4000 HZ Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires Optional Extender is for mounting to 4 backboxes with no extension ring. *RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (1633v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Product Overview The NEW VES Series of Ceiling Speakers and Speaker Strobes are designed for high efficiency sound output, with dual voltage (25/70 VRMS) capability and field selectable taps from 1/8 to 2 watts. These ceiling Speakers and Speaker Strobes are MultiCandela ceiling appliances are part of the new family of ceiling mount strobe appliances that will also be available on strobes, horns and horn/strobes. Optional Extender (E60 Ext) is for mounting to 4 backboxes with no extension ring. The ceiling mounted Speaker Strobe models incorporate the Low Current draw Series RSS Strobes. These ceiling mount round models are available in Wheelock patented MCC multicandela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The ceiling mounted Speakers and Speaker Strobes provide high audio output with clear audibility and are designed to meet the critical needs of the life safety industry for effective emergency voice communications, tone signaling and visible signaling to alert the hearing impaired. The low profile design incorporates a speaker mounting plate for faster and easier installation. Each model has a builtin level adjustment feature and snapon cover with no visible mounting screws. The strobe portion of all ceiling mounted series Speaker Strobes may be synchronized when used in conjunction with the VES Sync Modules or the VES PS248MC Power Supply with Patented Sync Protocol. VES synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy. The ceiling mounted series of Speaker Strobes are UL Listed for indoor use under Standard 1971 (Signaling Devices for the HearingImpaired) and Standard 1480 (Speaker Appliances), and use a enon flashtube with solid state circuitry enclosed in a rugged Lexan lens to provide maximum reliability for effective visual signaling. All inputs are supervised and employ IN/OUT wiring terminals for fast installation using #12 to #18 AWG wiring. Color options for the ceiling mounted series Speakers and Speaker Strobes are red and white. Table2: Ceiling Mount UL Reverberant dba 10 Feet** Watts Ceiling mount Speaker Ceiling mount Speaker Strobe 1/ / **dba ratings are based on UL testing under UL standard /

66 CEILING MOUNTED SPEAKER AND STROBE OPERATE INDEPENDENTLY (NONSYNC OR SYNC) FROM PRECEDING APPLIANCE OR VOICED EVACUATION PANEL FROM PRECEDING STROBE, SYN MODULE, POWER SUPPLY OR FACP STROBE + SPEAKER TO NET APPLIANCE OR EOLR TO NET STROBE OR EOLR CEILING MOUNTED SPEAKER STROBE APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS A FACP STROBE NAC CIRCUIT OUT STROBE NAC CIRCUIT RETURN + SYNC + OUT 1 + IN 1 MINUS 1 + AUDIBLE MINUS 2 + IN 2 + OUT 2 CEILING MOUNTED SPEAKER STROBES SYNCHRONIZED WITH MULTIPLE DSM MODULES F A C P Strobe NAC Cir. Strobe NAC Cir. Strobe NAC Cir. Sync + Sync + Sync + DSM Interconnecting wiring system shown. Maximum C twenty (20) Note: Figure shows interconnection to strobe through sync module. Speaker portion requires 2 separate conductors to FACP. CEILING MOUNTED SPEAKER STROBE APPLIANCES & RSS STROBES SYNCHRONIZED WITH PS12/248CP and PS12/248MP F A C P Series PS12/24 8MP or PS12/248CP OUTPUTS 14 4CLASS B OR 2CLASS A Series PS12/24 8MP or PS12/24 8CP RSS RSS RSS EOLR Technical Specifications and Ordering Information Model Wall Ceiling Non Mount Mount Sync VF VF VF VF VF VF VF VF /30/75/95 15/30/75/95 115/ /117 Q,U Q,U Q,U,V Q,U,V Q,U,V Q,U,V * * * * * * * * * * ** VF4418 is an extender ring that mounts behind the speaker to permit mounting to a 4 square x 2 1/8 deep electrical box without * Pending need for an extension ring on the box. Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with VES standard terms and conditions. Architects and Engineers Specifications Strobe Sync w/ SM, DSM or PS 12/24 8CP Strobe Candela Model Color White Mounting Options Agency Approvals UL MEA CSFM FM BFP The speaker appliances shall be VES Series Ceiling Mounted Speakers and the Speaker Strobe appliances shall be VES Series Ceiling Mounted Speaker Strobes or approved equals. The speakers shall be UL Listed under Standard 1480 for Fire Protective Service and speakers equipped with strobes shall be listed under UL Standard 1971 for Emergency Devices for the HearingImpaired. In addition, the strobes shall be certified to meet the requirements of FCC Part 15, Class B. All speakers shall be designed for a field selectable input of either 25 or 70 VRMS, with selectable power taps from 1/8 watt to 2 watts. All models shall have listed sound output of up to 87 db at 10 feet and a listed frequency response of 400 to 4000 Hz. The speaker shall also incorporate a sealed back construction. All inputs shall employ terminals that accept #12 to #18 AWG wire sizes. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a enon flashtube enclosed in a rugged Lexan lens. The strobe shall be of low current design. Where MultiCandela Speaker Strobes are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard /30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. When synchronization is required, the strobe portion of the appliance shall be compatible with VES sync modules or the VES PS248MC Power Supply with builtin Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a nonsynchronized flash rate. The speaker and speaker strobe appliances shall be designed for indoor flush mounting. The speaker and speaker strobe shall incorporate a speaker mounting plate with a snapon grille cover with no visible screws for a level, aesthetic finish and shall mount to standard electrical hardware. The finish of the VES Series Ceiling Mounted Speakers and Speaker Strobes shall be white or red. All speaker and speaker strobe appliances shall be backward compatible. Model Color Red

67 Speaker and Speaker Strobes Vandal Proof Speaker and Speaker Strobes Standard Features Approvals include: CAN/ULCS54199 for speaker appliances and CAN/ULCS52602 for visual appliances High efficiency design for maximum output at minimum wattage across a frequency range of 400 to 4000 HZ Field selectable taps for 25 VRMS operation from 1/8 watt to 2 watts Field selectable taps for 70 VRMS operation from 1/8 watt to 8 watts. The Vandal Proof Series of Speaker Strobes models available with 15 candela strobes featuring low current draw and low temperature compensation to reduce power consumption and wiring costs All audio and strobe inputs are compatible with standard reverse polarity type supervisions of circuit wiring by an alarm panel Four attractive package styles for flush, semiflush or surface mounting to low cost electrical backboxes Choice of vandal resistant die cast grilles or general purpose sheet metal grilles. Sealed back speaker construction for extra protection and improved audibility Sealed back speaker construction for extra protections and improved audibility Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires Product Overview VES Vandal Proof Series provides a full range of rugged, high performance speakers and speaker strobe combinations specifically designed to meet the critical needs of the life safety industry for voice and tone signaling. Available in compact, aesthetically pleasing package styles, each vandal proof model covers both 25 or 70 volt audio systems. Their highefficiency design provides improved evacuation signal, such as the slow whoop and code3. The Vandal Proof Series provides unequaled performance and installation flexibility at the job site, while minimizing confusion about mounting and performance capabilities. The Vandal Proof Series of Speaker Strobes use an enon flashtube with solid state circuitry enclose din a rugged Lexan lens to provide maximum reliability for effective visible signaling. All Vandal Proof models have IN and OUT wiring terminals that accept two #12 to #18 American Wire Gauge (AWG) wires at each terminal. Strobe inputs are polarized and audio inputs include a 10 uf blocking capacitor for compatibility with standard reverse polarity DC supervision of NAC circuits. General Notes Strobes are designed to flash at 1 flash per second minimum over their Regulated Voltage Range. VF4412 Speakers are Listed for indoor/ outdoor use with a temperature range of 35 C to 66 C (31 F to 150 F) and maximum humidity of 95% RH. All other ET Speakers and Speaker Strobes are Listed for indoor use with a temperature range of 0 C to 49 C (32 F to 120 F) and maximum humidity of 85%RH.

68 SPEAKER AND STROBE OPERATE INDEPENDENTLY FROM PRECEDING APPLIANCE + OR VOICE EVACUATION PANEL FROM PRECEDING STROBE, SYNC MODULE, POWER SUPPLY OR FACP STROBE SPEAKER + TO NET APPLIANCE OR EOLR TO NET STROBE OR EOLR CEILING FLUSH MOUNTING Circular Backbox for 4 Speaker available in Canada only Vandal Proof Series By Others (BO) Technical Specifications and Ordering Information Model Number VF4412 VF4414 VF4840 Speaker 10 Feet (Rated Watts) 1/8 1/4 1/ * 8* Strobe Voltage (VDC) NOM 24 Strobe Candela 15 Voltage 24 VDC 24 VFWR Rated Average Current LS Rated Peak Current LS Rated Inrush Current LS Note: All VFWR voltages in table are measured with DC Volt meter. Multiply VFWR voltage by 1.11 to convert to VRMS. Architects and Engineers Specifications The speaker appliance shall be a VES Series Vandal Proof speaker and speaker strobe appliance or equivalent. The speaker and strobes shall be ULC Listed under CAN/ULCS54199 and CAN/ULCS52602 for Fire Protective Service.All speakers shall be either 25 or 70 VRMS inputs with field selectable power taps. Strobes shall use filtered power or unfiltered power supply (fullwaverectified). All models shall have provisions for standard reverse polarity type supervision and IN/OUT field wiring using terminals that accept #12 to #18 AWG wiring. Combination speaker strobe appliances signals shall incorporate a enon flashtube enclosed in a rugged Lexan lens or equivalent with solid state circuitry. Strobe shall meet ULC and produce a flash rate of one (1) flash per second minimum over the Listed input voltage range. The strobe intensity shall be rated per ULC for 15 candela. The combination speaker strobe appliances shall be installed indoors and surface or flush mounted. They shall mount to standard electrical hardware requiring no additional trimplate or adapter. The appliance shall be finished in a textured red or white color.

69 Weatherproof appliances Speakers & Strobes Standard Features Approvals include: UL Standards 1971, 1638, 464 and 1480 California State Fire Marshal (CSFM) and New York City (MEA), Factory Mutual (FM) and Chicago (BFP). Compliance with the following requirements: NFPA, UFC, ANSI 117.1, OSHA Part 29, , ADA Weatherproof with extended temperature range of 40 F to 150 F (40 C to 66 C)* Dual Listed strobe models (UL 1638 and UL 1971) Industry s highest strobe candela options Synchronize using the VES Sync Modules or panels with builtin VES Patented Sync Protocol Models with field selectable tone, dba and candela settings Wall or ceiling mounting options Surface of semiflush mounting IN/OUT wiring termination accepting two #1218 AWG wires at each terminal Product Overview Designed for life safety, performance and reliability, VES s cost effective weatherpoof notification appliances includes the following Weatherproof Appliances: Strobes Horn Strobes Multitone Horn Strobes Speaker Strobes Speakers All strobe models are UL dual listed meeting both UL1638 and UL1971 requirements. As dual listed appliances, these weatherproof strobes, horn strobes and speaker strobes are listed for outdoor applications under UL 1638 as well as under UL 1971, the Standard for Safety Signaling Devices for Hearing Impaired. With an extended temperature range of 31 F to 150 F (40 C to 66 C), Wheelock weatherproof appliances meet or exceed UL outdoor test requirements for rain, humidity and corrosion resistance while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 strobe spacing tables (up to 185 candela for wall mounting and 177 candela for ceiling mounting). To enable weatherproof mounting, VES provides the industry s widest choice of mounting options for surface or unique semiflush installation. Models are available for surface mounting to VES weatherproof backboxes on walls or ceilings. The optional VF4987 allows the weatherproof backboxes (VF4966, VF4978 or VF4979) to be mounted to a recessed electrical box for concealed conduit installation. For semiflush installation, the VF4988 kits allow a customer to mount the weatherproof appliances to a recessed electrical box without the need for an external weatherproof backbox. See the Backboxes, Plates and Gaskets Table on page three of this datasheet for a summarization of these mounting options and the required accessories. All models may be synchronized using the VES Sync Modules, VES Power Supplies or other manufacturers panels incorporating the VES Patented Sync Protocol. The horn output of horn strobes can be independently controlled on 2wire circuits using the VES patented sync protocol. VF4607 horn strobe models are 4wire appliances; the strobes can be synchronized while the audible can be connected to a coded fire alarm system or can be set to produce any of eight selectable tones.

70 Wiring Diagrams MTWP FROM PRECEDING + APPLIANCE OR_ FACP RED BLACK + _ TO NET APPLIANCE OR EOLR NAC #1 FACP Sync Module or PS12/248 Power Supply Strobe Circuit Audible Circuit + _ + _ NAC #2 STROBE AUDIBLE FROM PRECEDING APPLIANCE OR FACP + _ + _ TO NET APPLIANCE OR EOLR FACP STROBE NAC CIRCUIT OUT DSM + SYNC +OUT 1 + IN 1 MINUS 1 + AUDIBLE RSSWP ASWP RSS + _ STROBE NAC CIRCUIT RETURN MINUS 2 + IN 2 + OUT 2 RSS ASWP RSS Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with VES standard terms and conditions. Agency Approvals Model Strobe VF4352 VF4604 VF4607 VF4832 UL MEA CSFM FM BFP Ordering Information Model VF VF VF VF VF VF VF Description * * * * * Pending Strobe wall Weatherproof, 75cd, Red Weatherproof Horn/ Strobe, Red (AS) Audible Multi Tone Strobe Weatherproof, 75cd, Red Weatherproof Speaker Strobe, Wall Strobe Wall Weatherproof, 75cd, Red Speaker VandalProof 8 Watt Surface Red Speaker VandalProof 8 Watt Surface White Candela Ratings Series UL 1971 UL 1638 UL 1638 VF4352, VF4832 and F VF4607 UL Max Current (Strobe only) High Med Low VF4352 VF4604 VF4607 VF4832 VF ** General Notes ** Wall Mount Rating only Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. All candela ratings represent minimum effective Strobe intensity based on UL Standards 1971 and 1638 as indicated in candela ratings table.

71 Mounting Accessories VF VF VF VF VF VF Ordering Information Gasket Kit VF Flush Plates VF Red VF White VF Red VF White Backboxes VF Red VF White VF Red VF White VF Red VF White VF Red VF White Mounting Options VF4352 Strobes VF4832 Speaker Strobes VF4604 Horn Strobes VF4412 Speakers VF4607 Multitone Horn Strobes Backboxes, Plates Surface Mount Exposed Conduit Concealed Conduit VF4979 VF4979+ VF4987 VF4966 VF4966+ VF4987 VF4978 VF4978+ VF4987 VF4977 VF4966 VF4966+ VF4987 Flush Mount VF4982 VF4982 VF4988 VF4982 VF4982 Architects and Engineers Specifications General Weatherproof notification appliances shall be UL listed for outdoor use. Weatherproof Strobe appliances shall be listed under UL Standard 1638 (Standard for Visual Signaling Appliances) for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired). The appliances shall be available for optional wall mounting or ceiling mounting to weatherproof backboxes using either exposed conduit or concealed conduit, or semiflush mounting to a recessed electrical box in walls or ceilings using VES mounting accessories. Weatherproof Strobes Weatherproof Strobe appliances shall produce a minimum flash rate of 60 flashes per minute over the UL Regulated Voltage Range of 16 to 33 VDC and shall incorporate a enon flashtube. The weatherproof strobes shall be available with UL 1971 candela ratings up to 185 cd for wall mounting and 177 cd for ceiling mounting. UL 1638 candela ratings up to 180 cd at 77 F shall be available. The strobes shall operate over an extended temperature range of 40 F to 150 F (40 C to 66 C) and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). Weatherproof Audibles and Audible/Strobe Combinations Weatherproof horns and multitone audibles shall be listed for Indoor/Outdoor use under UL Standard 464. The horns shall be able to produce a continuous output or a temporal code3 output that can be synchronized. The horns shall have at least 3 sound level settings. Horn/Strobe combinations shall be able to be synchronized on a single NAC. Multitone audibles shall be able to produce 8 distinct tones selectable by dip switch and shall have at least 2 sound level settings. Multitone Audible/Strobe combinations shall have independent inputs for the audible and strobe. The strobes shall be able to be synchronized. The audibles shall be able to be coded when operated on a separate NAC. Weatherproof Speakers and Speaker/Strobes Weatherproof speakers and speaker/strobes shall be listed for Indoor/Outdoor use under UL Standard All speakers shall provide field selectable taps for 1/8W to 8W operation for either 25 VRMS or 70 VRMS audio systems and shall incorporate a sealed back construction for extra protection and improved audibility. Speakers without strobes shall be VES Series VF4412. They shall be listed to produce up to 94 dba and shall incorporate a vandal resistant grille design. Synchronization Modules When synchronization of strobes or temporal code3 audibles is required, the appliances shall be compatible with the VES Series Sync Modules, VES Power Supplies or other manufacturers panels with builtin VES Patented Sync Protocol. The strobes and audibles shall not drift out of synchronization at any time during operation. Series VF4604 audibles and strobes shall be able to be synchronized on a 2wire circuit with the ability to silence the audible if required. The strobes on Series multitone audible/strobe appliances shall be able to be synchronized and shall be able to be operated on a separate circuit from the audibles while the audible circuit is connected to a coded or continuous NAC. Weatherproof Mounting Accessories Weatherproof mounting options shall include surface mounting or semiflush mounting to walls or ceilings. Surface mounted appliances shall mount to VES VF4966, VF4977, VF4978 or VF4979 weatherproof backboxes using either exposed conduit or concealed conduit. For concealed conduit the weatherproof backbox shall be mounted to a recessed electrical box with VES s VF4987 to provide a weatherproof seal for the electrical box. Semiflush mounted appliances shall mount to a recessed electrical box using VES VF4982 or VF4988 flush plates to provide a weatherproof seal between the electrical box and the appliance.

72

73 VF5350 Electromagnetic Fire Door Holders S2985 R :100 Standard Features Extremely low current draw. Only 20mA at 24V saves on power supplies and backup batteries New recessed mount for lowest profile look Dual voltage inputs in each units reduces stocking requirements Selfadjusting swivel catchplate reduces installation time and adjusts to door alignment changes Optional extension rods make installation faster Low residual magnetism easily releases even on new ADA low pressure door closers Builtin transient protection Overview The DH Series Electromagnetic Fire Door Holders are constructed of the finest materials and workmanship available. Each door holder is made of durable diecast metal and offered in a powdercoated finish. Installation is easy with DH Series installation technique an adhesive template assures alignment without secondary adjustments. No brackets are required for recessed, flush or surface mounting (the surface mounting box has three conduit ready entries). Plus, the new catch plate features two pivot points and two way adjustability to further ensure perfect alignment. Optional extension rods are also available for providing the proper gap distance between the door and wall. MEA approved 20097E APPROVED Floor mount units available The basic units offer superior reliability with builtin transient protection and low residual magnetism so they release easily even on new ADA low pressure door closers.

FIRE DETECTION SYSTEMS. Product Guide

FIRE DETECTION SYSTEMS. Product Guide FIRE DETECTION SYSTEMS Product Guide 2014-2015 FIRE DETECTION SYSTEMS VES was founded with one mission: to give dealers a comprehensive, cost-effective means of providing fire detection networks for corporate,

More information

FIRE DETECTION SYSTEMS. Product Guide

FIRE DETECTION SYSTEMS. Product Guide FIRE DETECTION SYSTEMS Product Guide 2014-2015 FIRE DETECTION SYSTEMS VES was founded with one mission: to give dealers a comprehensive, cost-effective means of providing fire detection networks for corporate,

More information

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator TECHNICAL GUIDE Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator The XPlorer Range XPlorer is a new range of analogue addressable detectors and interfaces developed for all who

More information

Series 65 Product Guide MAN 3036

Series 65 Product Guide MAN 3036 Series 65 Product Guide MAN 3036 TABLE OF CONTENTS Page No. 1 Ionisation Smoke Detector... 1 1.1 Operating Principles:... 1 1.2 Product Codes... 2 1.3 Integrating Version:... 2 1.4 Options:... 2 1.5 Safety

More information

FIRE DETECTION SYSTEMS. Product Guide

FIRE DETECTION SYSTEMS. Product Guide FIRE DETECTION SYSTEMS Product Guide 2016-2017 FIRE DETECTION SYSTEMS VES was founded with one mission: to give dealers a comprehensive, cost-effective means of providing fire detection networks for corporate,

More information

XP95 ENGINEERING PRODUCT GUIDE

XP95 ENGINEERING PRODUCT GUIDE XP95 ENGINEERING PRODUCT GUIDE Ionisation Smoke Detector Optical Smoke Detector Temperature Detector Multisensor Detector Manual Call Point Isolating Base The XP95 range of intelligent fire detectors is

More information

SERIES 65 ENGINEERING PRODUCT GUIDE

SERIES 65 ENGINEERING PRODUCT GUIDE SERIES 65 ENGINEERING PRODUCT GUIDE Wide Voltage Conventional Detectors Series 65 incorporates well-proven sensing technologies, including an Integrated Circuit based on that used in XP95 analogue addressable

More information

XP95 Product Guide MAN 3037

XP95 Product Guide MAN 3037 XP95 Product Guide MAN 3037 TABLE OF CONTENTS Page No. 1 Introduction... 1 2 Application of XP95 Detectors... 1 3 Addressing and Communications... 1 4 Approvals & Regulatory Compliance... 2 5 Protocol

More information

The supplier and installer of the system should be approved by the local civil defence authority.

The supplier and installer of the system should be approved by the local civil defence authority. ANALOGUE ADDRESSABLE FIRE ALARM SYSTEM 1. Scope of Work The contractor shall supply, install, test and commission a modern Analogue Addressable Fire Detection and Alarm System of an approved manufacturer

More information

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices. FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001

More information

SERIES 65 ENGINEERING PRODUCT GUIDE

SERIES 65 ENGINEERING PRODUCT GUIDE SERIES 65 ENGINEERING PRODUCT GUIDE Wide voltage conventional detectors Series 65 incorporates well-proven sensing technologies, including an IC based on that used in XP95 analogue addressable detectors.

More information

Engineering Product Guide Ionisation Smoke Detectors Optical Smoke Detectors Resettable Heat Detectors

Engineering Product Guide Ionisation Smoke Detectors Optical Smoke Detectors Resettable Heat Detectors Engineering Product Guide Ionisation Smoke Detectors Optical Smoke Detectors Resettable Heat Detectors SERIES 60 CONVENTIONAL FIRE DETECTORS Series 60 is a range of conventional fi re detectors, designed

More information

ENGINEERING PRODUCT GUIDE

ENGINEERING PRODUCT GUIDE RDM ENGINEERING PRODUCT GUIDE Radio linked detectors and interfaces CONTENTS Radio Detector Monitoring 1 RDM Ionisation Smoke Detector RDM Radio-linked detectors with base and interfaces Operating Principles

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description MODUL-R FIRE ALARM CONTROL PANELS MR-2900/MR-2920 Addressable Fire Alarm Control Panels Description MR-2900 Fire Alarm Control Panel The MR-2900 fire alarm system control unit is the heart of a sophisticated

More information

Analogue addressable devices

Analogue addressable devices Apollo XP95 Analogue addressable devices from Channel Safety Systems Apollo XP95 Analogue addressable devices The XP95 range of analogue addressable fire detectors is advanced in design, improved in performance

More information

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION Fike s CyberCat 254 (P/N 10-066) is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system.

More information

Laptop / PC Programming Manual

Laptop / PC Programming Manual Laptop / PC Programming Manual Doc. # Fire PC Program rev B 01.07 This Document is property of Evax Systems, Inc. The Evax Fire Solutions Programmer Components 2 1.0 System Setup 4 1.1 Interface Setup

More information

Intelligent Single Loop Fire Alarm Control Panel

Intelligent Single Loop Fire Alarm Control Panel Intelligent Single Loop Fire Alarm Control Panel The CAX-CTL-1L Intelligent Single Loop Fire Alarm Control Panel is a member of the industry leading Axis AX Series Intelligent Fre Alarm Control Panels

More information

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Intelligent 2 & 4 Loop Fire Alarm Control Panels Intelligent 2 & 4 Loop Fire Alarm Control Panels Advanced has combined the latest technology with many years of fire experience, to create the Axis AX Series Intelligent Fire Alarm Control Panels. The

More information

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features 990-052, Issue 6 20 March 2006 ID50 Series Single Loop Intelligent Fire Alarm Panels Section: Intelligent Fire Alarm Panels GENERAL The NOTIFIER ID50 series single loop intelligent fire alarm panels, has

More information

FireNET Plus Wiring Instructions

FireNET Plus Wiring Instructions FireNET Plus Wiring Instructions This manual provides wiring instructions for the 1 loop and 2 loop version of the FireNET Plus panels, which supports our finest Hochiki s DCP protocol. Note: Refer to

More information

TrueAlarm ES Analog Sensing

TrueAlarm ES Analog Sensing TrueAlarm ES Analog Sensing UL, ULC, CSFM Listed; FM Approved* Features TrueAlarm addressable sensor base with 520 Hz sounder TrueAlarm sensor bases with 520 Hz tone require a TrueAlarm photoelectric,

More information

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi 50 (P/N 10-071) is a state-of-the-art true intelligent digital peer-to-peer modular suppression control system.

More information

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum

More information

TrueAlarm Analog Sensing

TrueAlarm Analog Sensing UL, ULC Approved* TrueAlarm Analog Sensing TrueAlarm Analog Sensors Photoelectric and Heat; Standard Bases and Accessories Features TrueAlarm analog sensing provides: Digital transmission of analog sensor

More information

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi (P/N 10-068) is a state-of-the-art true intelligent digital peer-topeer modular suppression control system. It is ideal for

More information

Addressable Fire Alarm Control Panel

Addressable Fire Alarm Control Panel PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT

More information

ALK-V PHOTOELECTRIC SMOKE SENSOR

ALK-V PHOTOELECTRIC SMOKE SENSOR ALK-V PHOTOELECTRIC SMOKE SENSOR APPLICATION The HOCHIKI America ALK-V Photoelectric Smoke Sensor is particularly suited to detecting optically dense smoke typical of fires involving materials such as

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd full installation, commissioning and operating manuals can be downloaded from www.haes-systems.co.uk combined addressable / conventional fire alarm control panel User Guide Approved Document No. MFBU-04

More information

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual Australia Issue 01 April 2012 Contents 1 Introduction 3 2 Safety 3 3 Installation 4 3.1 Mounting the Cabinet 4 4 Specifications

More information

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options

More information

Multi-Point Peripherals

Multi-Point Peripherals UL, ULC Approved* Multi-Point Peripherals TrueAlarm CO Sensor Bases for Smoke, Heat, and Photo/Heat Sensors using IDNet Communications Features Fig 1: TrueAlarm CO Sensor Base with Sounder (shown with

More information

FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL The FireNET 427 control panel is an analog addressable fire alarm panel containing 2 or 4 SLC loops with each loop supporting 27 devices of

More information

The EN54 Part 2, 4 and 13 Fire System

The EN54 Part 2, 4 and 13 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION DOCUMENT CONTROL NUMBER / MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION 1. INTRODUCTION The MR300 range of optical smoke detectors forms part of the M300 series of plug-in

More information

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf Control Panels Analog Addressable Fire Alarm Control Panel Technical Manual TELEFIRE FIRE & GAS DETECTORS LTD PO Box 7036 Petach Tikva 49250 Israel Tel: 972 3 970 0400 Fax: 972 3 921 1816 email: Web: info@telefire.co.il

More information

System 800 Addressable Fire Detection & Alarm System

System 800 Addressable Fire Detection & Alarm System SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools

More information

LifeAlarm Fire Alarm Control Panels

LifeAlarm Fire Alarm Control Panels LifeAlarm Fire Alarm Control Panels UL, ULC Approved* Features Control panel operator convenience features: Wide viewing angle 2 x 20 (40 character) alphanumeric LCD and dedicated LEDs provide convenient

More information

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA CONVENTIONAL FIRE ALARM CONTROL UNITS MR-2300 SERIES Fire Alarm Control Units Description Secutron s MR-2300 Series fire alarm control panels consist of six and twelve zone models which are equipped with

More information

UNC100 Integra Manual

UNC100 Integra Manual UNC100 Integra Manual New Generation Building Security July 30, 2014 V1.2 Copyright Notice Copyright 1995-2014 by All rights reserved Worldwide. Printed in Canada. This publication has been provided pursuant

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection The Hart XL High Sensitivity Smoke Detection system (HSSD) is an aspirating fire detection system designed to give very early indication of an incipient fire condition.

More information

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide Product Overview The IntelliKnight 5820XL is an intelligent addressable fire alarm control panel designed for flexibility and reliability.

More information

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel ACC-25/50ZST Zoned System Voice with Telephone Evacuation Control Panel General The AUDIO COMMAND CENTER 25/50 Zone System with FireFighters Telephone (ACC-25/50ZST) is a state-of-the-art Emergency Voice

More information

Product Data Sheet. Remote Terminals. Features:

Product Data Sheet. Remote Terminals. Features: Remote Terminals Product Data Sheet Features: Based around two core products, the Mx- 4010 Remote Display Terminal (RDT) and the fully functional Mx-4020 Remote Control Terminal (RCT). Both remote terminals

More information

July 14, 1999 DF C-100.

July 14, 1999 DF C-100. www.firelite.com GENERAL The Fire Lite FIRE COMMAND 25/50 is a state-of-theart, compact, stand-alone or slave Emergency Voice Evacuation Control Panel (VECP). The FIRE COMMAND 25/50 is offered in a self-contained,

More information

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel DS9400 Series EN Release Notes for Firmware V2.07 Fire Alarm Control Panel DS9400 Series Release Notes for Firmware V2.07 Trademarks Trademarks Gentex is a trademark of Gentex Corporation, Fire Protection

More information

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906 s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones

More information

An introduction to... Sigma

An introduction to... Sigma An introduction to... Sigma XT+ Sigma XT+ Overview The Sigma XT+ 21000 series are the latest additions to the Sigma family of control equipment from Kentec Electronics Limited. The Sigma XT+ range combines

More information

TrueAlarm Analog Sensing

TrueAlarm Analog Sensing TrueAlarm Analog Sensing UL, ULC Listed* Addressable Duct Sensor Housings with TrueAlarm Photoelectric Sensor; Available with Multiple Relay Features Compact air duct sensor housing with clear cover to

More information

intelligent fire alarm ID60series panels

intelligent fire alarm ID60series panels intelligent fire alarm ID60series panels features LPCB approved to EN54 Parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports advanced detection such as

More information

Addressable Detectors & Bases

Addressable Detectors & Bases Edwards Signaling Catalog u Intelligent Initiating Addressable Detectors & Bases Detectors: E-PD, E-PHD, E-HD Bases: B4U, RB4U, IB4U, SB4U Overview Edwards intelligent addressable detectors are meticulously

More information

Section PERIMETER SECURITY SYSTEMS

Section PERIMETER SECURITY SYSTEMS Section 28 16 43 PERIMETER SECURITY SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Provide and install a perimeter security system as herein specified for the purpose of detecting entry into a designated security

More information

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range Fire Detection MINERVA Marine MX T2000 Panel Range Features: Enhances fire detection and eliminates unwanted alarms using fuzzy logic Assists fire fighting and training by providing on-screen risk management

More information

LF /2. Fire Alarm Control Panel. Features:

LF /2. Fire Alarm Control Panel. Features: LF-6100 1/2 Fire Alarm Control Panel Features: Microprocessor Based System Intelligent Distributed System Structure Quick Response Time Fire Alarm in less than 1 Second Capacity of 200/500 Addressable

More information

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION AnaLASER II Detector High-Sensitivity Smoke Detector (HSSD ) F-89-250 FEATURES Air Sampling Smoke Detector for Early Warning Applications Two Versions Available: Standard Detector and Ultra Detector STANDARD

More information

TrueAlarm Smoke Detectors

TrueAlarm Smoke Detectors UL, ULC Approved* TrueAlarm Smoke Detectors TrueAlarm Photoelectric Smoke Detector with TrueSense Smoke/Heat Detection Features detection. If any of these alarm conditions are experienced, an alarm is

More information

FireNET FN-LCD-S Serial Annunciator Installation and Operation Manual

FireNET FN-LCD-S Serial Annunciator Installation and Operation Manual FireNET FN-LCD-S Serial Annunciator Installation and Operation Manual Hochiki America Corporation 7051 Village Drive, Suite 100 Buena Park, CA 90621-2268 714.522.2246 Corporate Headquarters 800.845.6692

More information

30.45 Electric Release PDRP-2001

30.45 Electric Release PDRP-2001 The PDRP-2001 Fire Alarm Control Panel (FACP) is a six-zone control panel for single and dual hazard deluge and preaction applications. The FACP is compatible with conventional input devices (2-wire or

More information

ID50series. intelligent fire alarm panels

ID50series. intelligent fire alarm panels ID50series intelligent fire alarm panels features LPCB approved to EN54 parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports NOTIFIER advanced range of

More information

Conventional Releasing Control Panel

Conventional Releasing Control Panel s Data Sheet Fire Safety Products Conventional Releasing Control Panel Pre-Action Deluge Agent-Releasing Fire System Model TXR-320 Remote configurable Up to two (2) hazard areas Operable with the following:

More information

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR ED820 24V MODEL fire DETECTOR INSTRUCTION MANUAL Address: Enigma House, Enigma Business Park, Malvern, Worcestershire, WR14 1GD Tel: 44 (0)1684 891500 Fax: 44 (0)1684 891600 Email: sales@electronicdevices.co.uk

More information

Consultant Specification AGILE Wireless Fire Detection System

Consultant Specification AGILE Wireless Fire Detection System Contents Scope of Work... 2 The EN54 Part 2 & 4 Fire System... 2 Standards... 2 Wireless Intelligent Photoelectric Smoke Detector Specification... 4 Wireless Intelligent Thermal Heat Detector Specification...

More information

PSN-1000 & PSN 1000(E) Installation Manual

PSN-1000 & PSN 1000(E) Installation Manual PSN-1000 & PSN 1000(E) Installation Manual Potter Electric Signal Company, LLC St. Louis, MO Customer Service: (866) 240-1870 Technical Support: (866) 956-1211 Fax: (314) 595-6999 www.pottersignal.com

More information

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description CONVENTIONAL FIRE ALARM CONTROL PANELS SFC-200 Series Fire Alarm Control Panels Description Summit s SFC-200 Series fire alarm control panels consist of six and twelve zone models which are equipped with

More information

Fire Product Catalog

Fire Product Catalog Additional Expansion Modules Fire Product Catalog CLEVER FIRE SOLUTIONS MA 1000 / Analog Addressable Fire Alarm Panel 1 Military Industry Public Buildings Industrial & Commercial Company Profile We are

More information

optical detector multisensor detector heat detector mounting bases product guide

optical detector multisensor detector heat detector mounting bases product guide optical detector multisensor detector heat detector mounting bases product guide ...conventional detectors from Apollo orbis is a range of conventional detectors which has been developed and tested to

More information

4007ES Fire Control Panels

4007ES Fire Control Panels UL, ULC, CSFM Listed; FM Approved* Features Flexible standard combination of addressable initiation and addressable notification 4.3 (109 mm) Diagonal color touchscreen display: Convenient and intuitive

More information

The EN54 Part 2 & 4 Fire System

The EN54 Part 2 & 4 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING GENERAL The VEC 25/50 is a state-of-the-art, compact, stand-alone or slave Emergency Voice Evacuation Control. The VEC 25/50 is offered in a self-contained, cost-effective design and includes a 25 Watt,

More information

good things in small packages

good things in small packages FireShield Control Panels good things in small packages life safety for small buildings and shops A perfect arrangement FireShield offers the very best conventional fire alarm technology available, with

More information

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1 Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User

More information

Multi-Point Peripherals

Multi-Point Peripherals Multi-Point Peripherals UL, ULC, CSFM Listed; FM Approved* TrueAlarm CO Sensor Bases for Smoke, Heat, and Photo/Heat Sensors using IDNet Communications Features TrueAlarm addressable CO sensor bases contain

More information

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117 Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel Revision E 61117 CAUTION: (Read This First) This panel has been designed to make it nearly bullet proof to mistakes made when wiring

More information

Public Safety DAS Annunciator Panel

Public Safety DAS Annunciator Panel Public Safety DAS Annunciator Panel 120 VAC Models: 1221-A, 1221-B, 1221-C Revision D 91117 48 VDC Models: 1221-A-48, 1221-B-48, 1221-C-48 24 VDC Models: 1221A-24, 1221-B-24, 1221-C-24 CAUTION: (Read This

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide System Reset Trou ble Silence Ala rm Silence Manual Ala rm ENTER NO YES Letters Numb ers Keyword Radionics System Reset Trouble Silence Alarm Silence Manual Alarm ENTER NO YES Le ters Numbers Keyw ord

More information

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K PEGAsys Multi-Loop Intelligent Suppression Control System A UTC Fire & Security Company Effective: March 2007 K-76-028 FEATURES UL Listed CSFM Approved MEA Approved Peer-to-Peer Networking (to 32 nodes)

More information

Remote NAC Power Supply D7038

Remote NAC Power Supply D7038 Operation and Installation Guide Remote NAC Power Supply D7038 D7038 REMOTE NAC POWER SUPPLY Page 2 2005 Bosch Security Systems Contents Contents 1.0 Overview...5 1.1 Module Control...5 1.1.1 Option Bus

More information

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R Region Project Page 1 PART 1 - GENERAL 1.1 REFERENCES.1 CAN/ULC-S524-2006, Standard for the Installation of Fire Alarm Systems..2 CAN/ULC-S525-2007, Audible Signal Device for Fire Alarm Systems..3 CAN/ULC-S526-2007,

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems OPERATOR OPERATOR OR TROUBLE CONDITION: TO : FIRE PRIORITY 2SYSTEM SYSTEM SIGNALS POWER INDICATOR. SUPERVISORYTROUBLE SILENCED ON D. TO SILENCE SIGNALS: - PRESS " SILENCE". SUPV TBL SYSTEM ACK ACK ACK

More information

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5 Construction Standards Page 1 of 5.1 General Description.1 The University requires that all new fire alarm system control panel, components, and devices, as required for the project, be Secutron 2900 Series

More information

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION 1. GENERAL SPECIFICATION 1.1 The contractor shall provide an Intelligent AlarmLine Linear Heat Detection System to perform the following functionality: A. Fire Alarm, Supervisory and Trouble-Event Initiation

More information

ACP10 & ACP50 Security Systems

ACP10 & ACP50 Security Systems ACP10 & ACP50 Security Systems System Configuration LCD Keypad LCD Keypad LED Keypad LED Keypad 4-wire Bus ACP10 & ACP50 AEX10* AEX10* AEX10* AEX10* * ACP50 Only Control Panels The ACP10 control panel

More information

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS ECC-50/100(E) Emergency Command Center DF-60734:A4 General Firelite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,

More information

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable Protec Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE Protec Protec Algo-TecTM 6100 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL

More information

Analog Room Pressure Monitor RPC Series

Analog Room Pressure Monitor RPC Series Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the

More information

FEC400 Series. Installation Manual

FEC400 Series. Installation Manual FEC400 Series Conventional microprocessor controlled fire detection and alarm panels with extinguishing control Installation Manual Version 2.3 / August 2004 Aritech is a GE Interlogix brand. http://www.geindustrial.com/ge-interlogix/emea

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

Operation and Maintenance Manual

Operation and Maintenance Manual (FKER Series) Repeater Panel (FKER, FKER, FKER8) Operation and Maintenance Manual Man-9EL Issue June Index Section Page. Introduction.... Safety and mounting.... Technical specification.... Control panel

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection Hart XL High Sensitivity Smoke Detection (HSSD) TM is a smoke detection system that is simple to install, commission, service and use yet remains brilliantly capable in

More information

Solution F2. Fire Alarm Control Panels one step ahead.

Solution F2. Fire Alarm Control Panels one step ahead. Solution F2 Fire Alarm Control Panels one step ahead. Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F2 Solution F2 in B2 enclosure (B01090-00) The Concept The Solution

More information

Excel-EN Conventional Fire Control Panel

Excel-EN Conventional Fire Control Panel Available as 2, 4, 6, 8,10 or 12 zones Approved to EN54-2 & 4 Modular expansion zone cards Programmable relays and outputs Optional additional sounder circuits Optional additional programmable outputs

More information

DCS-100. intelligent damper control & monitoring system

DCS-100. intelligent damper control & monitoring system DCS-100 intelligent damper control & monitoring system 02 //DCS-100 Introduction The Disys Technologies DCS-100 is a revolutionary new control system designed specifically for the fire/smoke damper controls

More information

4 wire conventional alarm system

4 wire conventional alarm system Scimitar 4 wire conventional alarm system from Channel Safety Systems Scimitar 4 wire conventional alarm system The Scimitar Fire Alarm Control System is a comprehensive range of high specification conventional

More information

OPEN SPRINKLER SYSTEM

OPEN SPRINKLER SYSTEM OPEN SPRINKLER SYSTEM Introduction Competence and innovation driven by consistent market development and customer requirements have shaped the successful development of the SHIELD Brand. The extensive

More information

Conventional Smoke Detectors KFAPO

Conventional Smoke Detectors KFAPO Kingfisher Company, inc. Conventional Smoke Detectors KFAPO Features: Wide operating voltage, 9-33 VDC Advanced electronic technology Flashing LED Magnetic test switch Proven detection performance Designed

More information

OPERATION AND INSTALLATION MANUAL

OPERATION AND INSTALLATION MANUAL EX+Plus 2 ZONE, 1AREA EXTINGUISHANT CONTROL PANEL OPERATION AND INSTALLATION MANUAL INTRODUCTION The Premier EX Plus is a 2 zone, single area panel for controlling the release of extinguishing gases in

More information

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014 January 16, 2014 Release Control Panel 290a 1. Description The Viking VFR400 is a microprocessor based releasing control panel for use on preaction, deluge, Surefire, Firecycle multicycle sprinkler systems,

More information

4007ES Fire Control Panels

4007ES Fire Control Panels UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved* 4007ES Fire Control Panels 4007ES Hybrid, Fire Detection and Control Panel with Addressable and/or Conventional Initiation Features Satisfies a variety

More information