21-light Remote Annunciator. Owner s Manual

Size: px
Start display at page:

Download "21-light Remote Annunciator. Owner s Manual"

Transcription

1 21-light Remote Annunciator Owner s Manual

2 Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With Generator Control System... 1 Relay Outputs (J1 - J8) - 0G5719 & 0G5720 Only... 1 Alarm Relay Output (J9)... 1 Transportation and Storage... 1 Installation and Mounting... 2 Relay Annunciation (J1 - J8)... 2 Parameter Selection Examples... 3 Parameters S1.1 - S1.10 & S2.1 - S Parameter "Generator Run"... 4 Parameter "Generator Power"... 4 Parameter "Line Power"... 4 Parameter "Battery Charger AC Failure"... 4 Generator Stop Indicators... 4 Warning Indicators... 4 Spare Indicator... 5 System Status Indicators... 5 System Ready... 5 Communication OK... 5 System Keypad Switches... 5 Test Switch... 5 Re-arm Horn Switch... 5 Reset Switch... 5 Spare Keypad Switch... 6 Other Functions...6 Graphical User Interface (GUI) or DIP Switches Enabled - DIP Switch S Master/Slave Mode - DIP Switch S Spare Keypad Switch - DIP Switch S Baud Rate Selection (DIP Switch S4)... 6 Alarm Relay (J9)... 7 RS485 Line Termination Resistor... 7 Graphical User Interface (GUI)... 7 RS485 Communications... 7 Serial Interface... 7 Communications Connect Time... 7 Error Handling... 8 Limits of Operation... 8 Terminology & Abbreviations... 8 Troubleshooting Guide... 9 ANNUNCIATOR DESCRIPTION The remote annunciator is available in the following versions: 0G Remote Annunciator has both relays and LEDs/ Keypad (RRP & RAP) 0G RRP version - Remote Relay Panel (Relays with no LEDs/Keypad) 0G RAP version - Remote Annunciator Panel (LED's/ Keypad without relays J1 - J8) The Remote Annunciator provides remote monitoring and annunciation of up to 18 generator parameters using the lights/leds located on the annunciator keypad. Selected generator parameters can be annunciated using the eight Form A relays provided on 0G5719 and 0G5720. The Remote Annunciator also provides two system-level warnings which are System Ready and Communications OK. Multiple annunciators can also be connected to obtain remote monitoring and annunciation of all 18 generator parameters. Power to the remote annunciator is supplied from the generator battery (+12VDC or +24VDC). Communication with the Remote Annunciator is via a RS485 serial data link. The remote annunciator is typically configured for listen only mode (also called slave or passive mode). In this operating mode, the annunciator receives information on the generator status, from the generator controller and activates/deactivates the relay outputs to reflect the status of up to eight selected generator parameters. The remote annunciator can also be configured to request status information from the generator (called master or active mode). The specific faults to be annunciated using the relay outputs (J1 - J8) can be selected using either the DIP switches located on the annunciator printed circuit board, or the Graphical User Interface (GUI) available using a computer via the RS232 connector on the annunciator printed circuit board (see Figure 2). Relays J1 - J8 provides a set of normally open contacts. All relays are energized (contacts closed) when power is applied to the annunciator. The relay selected to annunciate a particular fault will then open during a fault. The terminal block connections (J10), used to connect the battery supply and the RS485 communication lines to the remote annunciator are shown in Figure 1. The location of DIP switches S1, S2, S3 and S4 and the RS232 connector are shown in Figure 2. Figure 1 Connector J10 GND Shield Screen RS485 Data

3 Figure 2 Location of DIP Switches, RS232 Connector & JMP1 JUMPER BETWEEN 1 & 2 = RS485 TERMINATING RESISTOR IN CIRCUIT JUMPER BETWEEN 2 & 3 = TERMINATING RESISTOR OUT OF CIRCUIT JUMPER MISSING = TERMINATING RESISTOR OUT OF CIRCUIT 3 JMP1 1 1 RS232 DB9 CONNECTOR USED WITH THE GRAPHICAL USERINTERFACE (GUI) S1 1 S2 FACTORY USE ONLY J10 J1 J2 J3 J4 J5 J6 J7 J8 J9 S3 S4 1 1 GREEN STATUS LED DETAILED SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS Operating Temperature -25 C (-13 F) to +60 C (140 F) Humidity 0 to 95% Non Condensing POWER SUPPLY REQUIREMENTS Power Supply Source Power Supply Voltage Power Usage Power Supply Cable Generator Battery to comply with NFPA +12 or +24VDC (Annunciator operating range is 6V to 30VDC 6 Watts (typical when all the relays and keypad are energized) 2 wire - Voltage drop across each conductor must be less that 1V. COMMUNICATION WITH GENERATOR CONTROL SYSTEM Communication Link 2 wire RS485 fully isolated. Communication Cable 2 wire RS485 twisted pair with overall shield/screen (i.e. Belden 3105A). Maximum Cable Length 4,000 feet Baud rate Auto-detect at 57.6K, 38.4K, 9600 or 4800 (no parity, 2 stop bits). 1. The RS485 cable should not be run in the same conduit, or in the same wire grouping as any high voltage or high current conductors. 2. The generator control panel Baud Rate should be selected to be compatible with other components that are connected to the RS485 communication line. RELAY OUTPUTS (J1-J8) - 0G5719 & 0G5720 ONLY Contact per Channel Maximum contact rating ALARM RELAY OUTPUT (J9) Contact Type Maximum contact rating TRANSPORTATION AND STORAGE One Normally Open contact. Energized when annunciator is powered and no faults are present. 30VDC/1A SPDT (N.O. & N.C. contacts) Energized when annunciator is powered and no faults are present. 30VDC/1A Temperature -30 C (-22 F) to +80 C (176 F) Humidity 0 to 95% Non Condensing 1

4 INSTALLATION AND MOUNTING 3. For ALL models installation must always comply with applicable codes, standards, laws and regulations. Adhere strictly to local, state and national electrical and building codes. Comply with regulations the Occupational Safety and Health Administration (OSHA) has established. Also, the generator and related components must be installed completely in conformance with the manufacturer s instructions and recommendations. Following proper installation, do nothing that might alter a safe installation and render the unit in non-compliance with such codes, standards, laws and regulations. 4. The plastic knockout that is used to route the wires and cables into the annunciator should be removed with the annunciator firmly supported by placing it on a flat surface. 5. Wire tie-downs are provided in two places on the base of the annunciator to provide strain-relief for the connecting cables and wires (Figure 3). RELAY ANNUNCIATION (J1 - J8) The user can select up to eight of the following 18 generator parameters to annunciate via the relays, when the 10 position (S1) and the 8 position (S2) DIP switches on the annunciator PCB are being used. S1 Parameter S2 Parameter 1 RPM Sensor Loss 1 Battery Charger AC Failure 2 Overcrank 2 Low Battery Voltage 3 Overspeed 3 High Battery Voltage 4 Low Oil Pressure 4 Generator Run 5 High Water Temp/Low 5 Generator Power Water Level 6 Emergency Stop 6 Not in Auto 7 Pre-Low Oil Pressure 7 Line Power 8 Pre-High Water Temp 8 Spare Channel 9 Pre-Low Water Temp 10 Pre-Low Fuel Relay outputs J1 through J8 are assigned to the selected parameters in sequential order. For example, if DIP1-1 through 8 are selected, these faults are assigned to relays 1 through 8 respectively as shown in Figures 4 and 5. Figure 3 Enclosure Mounting Dimensions KNOCKOUT (3 PLCS) FOR 1/2" CONDUIT WIRE TIE-DOWN (2 PLCS) 7 x 12MM SLOT (4X) 2

5 Figure 4 DIP Switch S1 Settings Figure 7 S2 Figure 5 DIP Switch S2 Settings 6. If a unit is wired up and then subsequently an additional DIP switch position is selected or deselected, all the relay outputs are re-assigned sequentially and therefore the annunciator terminals may require re-wiring. Example 2 If subsequently DIP1-3 is removed, and DIP2-5 is added, then relays will be re-assigned (Figures 8 and 9). DIP Parameter Relay 1, 1 RPM Sensor Loss 1 1, 5 High Water Temp/Low Water Level 2 1, 10 Pre-Low Fuel 3 2, 5 Generator Power 4 Figure 8 S1 PARAMETER SELECTION EXAMPLES Example 1 DIP S1-1, 3, 5, 10 are initially selected, these are assigned to relays 1, 2, 3, 4 (Figures 6 and 7). DIP Parameter Relay 1, 1 RPM Sensor Loss 1 1, 3 Overspeed 2 1, 5 High Water Temp/Low Water Level 3 1, 10 Pre-Low Fuel 4 Figure 9 S2 Figure 6 S1 PARAMETERS S1.1 - S1.10 & S2.1 - S2.3 When a remote annunciator (0G5719) or Remote Relay Panel (0G5720) is used in a Modular Power System (MPS), an alarm on any one of the generators causes the associated relay to activate. 3

6 PARAMETER "GENERATOR RUN" This parameter is defined as any one or more generators in the system running. PARAMETER "GENERATOR POWER" This light/led indicates different things depending on the type of system it is attached to. It is defined as whether the Transfer Switch is in the Generator Supply Position. For a PowerManager System Controller (PM-SC with external transfer switch(es)), generator power is defined as any one or more generators in the system running and connected to the generator bus. For a non-paralleling engine controller (PM-GC WITHOUT internal transfer switch), it represents the status of input 4 (TB2-5) to the generator controller. This should be connected to the generator side auxiliary contact of the external transfer switch. A closure to ground will cause the light to illuminate. This shows whether the load is powered by the generator. For an engine controller that is part of an MPS system, generator power represents the state of the internal contactor that the generator is connected to. PARAMETER "LINE POWER" This light/led indicates different things depending on the type of system it is attached to. Is defined as whether the Transfer Switch is in the Utility Supply Position. For a Power Manager System Controller (PM-SC with external transfer switch(es)), line power represents the auxiliary input C (TB6-4). For a non-paralleling engine controller (PM-GC WITHOUT internal transfer switch), it represents the status of input 3 (TB2-4) to the generator controller. This should be connected to the utility side auxiliary contact of the external transfer switch. A closure to ground will cause the light to turn ON. This shows whether the load is power by the utility. For an engine controller that is part of an MPS system, line power is not used. PARAMETER BATTERY CHARGER AC FAILURE This light/led annunciates upon loss of 120VAC power supply to the battery charger and is communicated to the Annunciator by the generator controller. GENERATOR STOP INDICATORS These lights/leds will flash when any alarm occurs and the horn will sound as follows: Annunciator Light Light Color Audible Alarm RPM Sensor Loss Red Yes Overcrank Red Yes Overspeed Red Yes Low Oil Pressure Red Yes High Water Temp Red Yes Low Water Level Red Yes Emergency Stop Red Yes 7. Both the High Water Temp and the Low Water Level LEDs will turn ON if either fault condition is present. The "Re-arm Horn" switch can be used to turn off and re-arm the horn, or the alarms can be fully acknowledged using the "Reset" switch. The "Reset" switch will turn off and re-arm the horn, and any flashing lights will switch to the ON state until the alarms are no longer present at the generator control panel. 8. The alarm condition must be reset at the generator control panel. 9. When this annunciator is used in a Modular Power System (MPS), an alarm on any one of the generators will cause the lights/leds to light, and alarms to sound. WARNING INDICATORS These lights/leds will flash when any alarm occurs and the horn will sound according to the following table: Annunciator Light Light Color Audible Latched Alarm Pre-low Oil Pressure Yellow Yes Yes Pre-high Water Temp Yellow Yes Yes Pre-low Water Temp Yellow Yes Yes Pre-low Fuel Yellow Yes Yes Battery Charger AC Yellow Yes No Failure Low Battery Voltage Yellow Yes No High Battery Voltage Yellow No No Generator Run Yellow No No Generator Power Yellow No No Not in Auto Red Yes No 4

7 These alarms will be latched/not latched by the annunciator according to the above table. They can be acknowledged at the annunciator using the Reset' switch the active lamps will then stop flashing and remain in the ON state until the alarm signal clears from the generator control panel. The "Reset" switch will also turn off and re-arm the horn. 10. These lights can only be fully reset when the alarm state is no longer active and Reset has been pressed at both the generator control panel and the remote annunciator. Alternatively, at any time the horn can be turned OFF and re-armed with the "Re-Arm Horn" switch. 11. When this annunciator is used in a Modular Power System (MPS), a warning on any one of the generators will cause the above lights to light, and alarm to sound (if the warning is audible). SPARE INDICATOR The spare indicator light/led can be activated from the PM-GC or PM-SC by using the Integrated Logic Controller (ILC) feature in the G-panel or H-panel. Also see the section in this manual describing the operation and set-up of the spare keypad switch. Annunciator Light Light Color Audible Alarm System Ready Green Yes Communication OK Green Yes Line Power Green No Spare Green No SYSTEM STATUS INDICATORS These lights/leds are for Status indication only the normal condition is ON. SYSTEM READY The System Ready is defined as ALL in service generators are ready to start, run, and supply power. Any generators manually declared as out of service will not affect this LED. Upon a loss of System Ready, the annunciator will respond as follows: 1. The System Ready LED will begin to flash. 2. The alarm will sound. The Re-arm Horn switch can be used to turn off and re-arm the horn, or the alarm can be fully acknowledged using the reset switch at which time the System Ready LED will turn off and remain off until the System Ready status is returned. COMMUNICATION OK This LED will be ON as long as there is proper communication between the Remote Annunciator Panel and the Generator control system. It typically requires less than a minute for the Annunciator to determine the correct baud rate and connect to the RS485 bus. When communication failure occurs, the Annunciator will flash the communication LED, and sound the horn. The rate of flashing will be indicative of the cause of error. 1. No reply from the generator control system, Frequency = one second ON/one second OFF 2. Consecutive data errors, Frequency = 0.5 second ON/two seconds OFF. This alarm condition can be acknowledged at the Annunciator using the reset switch - the horn will be turned off and re-armed, and the communication OK light will continue to flash until proper communication returns. GREEN STATUS LED (INTERNAL TO UNIT) If the green LED is flashing at a one second on and one second off rate, the unit is operational and is configured from the Windows Graphical User Interface. If the green LED is flashing at a one second off and five seconds on rate, the unit is operational and is configured from the DIP switches. If the green LED is flashing at a half second on and five seconds off rate, the unit is operational but there are no RS485 communications. If the unit is powered for 30 seconds and the Green Status LED does not turn on at all during this time, the circuit board is not functional. SYSTEM KEYPAD SWITCHES TEST SWITCH While the test switch is pressed, all lights/leds will light and the horn will sound. When released the lights/leds will return to their original status. During this test, communication to the generator control system will be suspended. RE-ARM HORN SWITCH The re-arm horn switch will silence the alarm horn and re-arm it for new alarm occurrences. RESET SWITCH The reset switch is used to acknowledge any active alarms. It will re-set any flashing light/led s to a ON (steady) condition (or OFF for normally on lights). If the alarm no longer exists and it has also been latched OFF at the generator control panel (pre-alarm indicators only) the active light will go OFF. It will also silence the horn and re-arm it for new occurrences. 5

8 12. Pre-alarm conditions MUST be reset at the generator set control panel. SPARE KEYPAD SWITCH When DIP Switch S3, Position 4, is in the ON position, it allows the SPARE Keypad Switch to control Relay 8. When this DIP switch is in the ON position, pushing the SPARE keypad Switch will energize Relay 8 and turn on the spare light/led on the keypad. Pushing the SPARE keypad Switch again will de-energize Relay 8 and turn off the spare light/led. 13. The Remote Start capability using the Spare Keypad Switch and Relay 8 is only available when Remote Annunciator version P/N 0G5719 is used. OTHER FUNCTIONS GRAPHICAL USER INTERFACE (GUI) OR DIP SWITCHES ENABLED - DIP SWITCH S3-1 When Position 1 is in the ON position the Graphical User Interface (GUI) must be used to set the relay fault conditions. When Position 1 is in the OFF position the DIP switches on the Annunciator control board must be used to set the relay fault conditions. MASTER/SLAVE MODE - DIP SWITCH S3-3 Position 3 is used to configure the Annunciator as either a Slave (OFF position) or as a Master (ON position). In Slave mode, it is a Modbus slave and must be connected to a master port on the PM-GC or PM-SC. This method allows for the connection of more than one Annunciator. In Master mode, the Annunciator is the Modbus master and will request data from the PM-GC or PM-SC. The PM-GC or PM-SC must be set as a slave port when the Annunciator is configured as the Master (Figures 10 and 11). Figure 10 Annunciator s connected to an H-panel or G-panel Engine Controller PM-GC (Master) Annunciator (Slave) Annunciator (Slave) Figure 11 Annunciator s connected to a System Controller (SC) and Multiple G-panels PM-SC (Master) Annunciator (Slave) Annunciator (Slave) G-panel (Slave) G-panel (Slave) SPARE KEYPAD SWITCH - DIP SWITCH S3-4 Position 4, when it is in the ON position, it allows the SPARE Keypad Switch to control Relay 8. When this DIP switch is in the ON position, pushing the SPARE keypad Switch will energize Relay 8 and turn on the spare LED on the keypad. Pushing the SPARE keypad Switch again will de-energize Relay 8 and turn off the SPARE LED. This feature can be used to implement a Remote Start function. This Remote Start feature is only available with the Remote Annunciator version (0G5719) that has both the Relays and the Keypad. BAUD RATE SELECTION (DIP SWITCH S4) DIP Switch S4 can be used to set the Communications Baud Rate to a pre-determined value (see table). S4-1 S4-2 Baud Rate OFF OFF Auto-Baud Rate detect (max rate is 57600) OFF ON ON OFF 9600 ON ON

9 ALARM RELAY (J9) The Annunciator provides a relay with both a Normally Open contact and a Normally Closed contact. This relay is energized when DC power is provided to the Annunciator so that in the event power to the Annunciator fails the relay contacts will change state. When the Audible alarm is activated this relay will be de-energized. RS485 LINE TERMINATION RESISTOR A 1000 ohm RS485 terminating resistor is installed on the Remote Annunciator PC board via a 3-position jumper (JMP1 in Figure 2). In most applications this 1000 ohm terminating resistor is connected and the jumper (JMP1) is in the closed or 1-2 position. This jumper can also be moved to the open or 2-3 position. GRAPHICAL USER INTERFACE (GUI) A DB9 connector is provided on the Annunciator Control Board for use in setting the Annunciator functions. A GenLink serial cable (P/N 0F7707) should be used to connect a laptop computer s RS232 serial port to the Annunciator DB9 connector. The GenLink cable is a Null-Modem style serial cable with female-to-female DB9 connectors. Shown in Figure 12 is a typical Windows GUI interface as it appears on the computer display. RS485 COMMUNICATIONS In a typical application, the Annunciator monitors (i.e. slave mode) the Generator control system via the RS485 communication line. SERIAL INTERFACE Baud Rate Auto-Detect 57.6K, 38.4K, 9600 or 4800 (No Parity, 2 Stop Bits) COMMUNICATIONS CONNECT TIME When an Annunciator is powered up onto an existing RS485 network, there will be a period of time, during which the unit may report a communication failure. During this time the Annunciator is searching for the correct Baud rate. The Annunciator will typically communicate within one minute after being connected. Figure 12 Annunciator GUI Interface Display 7

10 ERROR HANDLING An error will be reported by flashing the Communication OK light the rate of flashing will be indicative of the cause of the error. 1. No reply from generator control system frequency one second on/one second off. 2. Consecutive data errors frequency 0.5 seconds on/two seconds off. The Annunciator, if configured for auto-baud rate detect, will try several times at each of four different baud rates (57.6K, 38.4K, 9600 and 4800) before reporting a communication error by deenergizing all the relays and then flashing the Communication OK light. LIMITS OF OPERATION The following communication restrictions apply for multiple units on a common RS485 line: A maximum of 15, 1000 ohm RS485 Loads (i.e. 57.6K Annunciator, G-panel, H-panels, etc) can be connected to the RS485 bus at one time. 14. There MUST be only ONE (1) master in the RS485 communication bus. All others must be slaves (PASSIVE). TERMINOLOGY & ABBREVIATIONS GUI - Graphical User Interface for Windows based computers MPS - Modular Power System PM-GC - Power Manager Generator Controller (controls a single Generator) PM-SC - Power Manager System Controller (used to control multiple Generators) LEDs - Light Emitting Diodes GenLink - Generator communication system ILC - Integrated Logic Controller RRP - Remote Relay Panel (Relays with no LEDs/Keypad), 0G5720 RAP - Remote Annunciator Panel (LEDs/Keypad without Relays J1 - J8), 0G5721 8

11 TROUBLESHOOTING GUIDE No Lights/LEDs are Lit. 1. Check for the proper battery supply at terminal block J10 pins 1 and 2. J10 pin 1 should be + Battery (12 or 24 volts). J10 pin 2 should be Battery. Refer to the power supply requirements section at the beginning of the manual for cable specifications. The Communication OK LED is flashing at the rate: second ON/one second OFF. 1. Does the RS485 communications cable meet specifications. Refer to the Communication with generator control system section at the beginning of this manual. 2. Check that the RS485 connections are connected properly. RS485+ connected to J10 pin 5. RS485 connected to J10 pin 6. Is the Shield/screen connected correctly. The shield/screen should be connected at the Generator end only. 3. Check for proper installation of the RS485 cable between the Annunciator and the generator s control panel. Is this cable sharing a conduit or running next to any high voltage or high current electrical lines? 4. Use the Generator Controller GenLink communication diagnostics to check if data is being sent or received via the Tx and Rx check boxes. Go to the pull-down menu for diagnostics and select Com Ports. Select the port the Annunciator is connected to (normally port 0) and look to see if the check boxes change state. If not, data is not being transmitted/ received, check the cabling. If data is being received, check the baud rate settings of all connected equipment. The Communication OK LED is flashing at the rate: 0.5 seconds ON/two seconds OFF. The "Green Status LED" (internal to the unit) is flashing at a 0.5 second ON/5 second OFF rate. 1. Does the RS485 communications cable meet specifications? Refer to the Communication with generator control system section at the beginning of this manual. 2. Is the cable shield connected correctly? The shield/screen should be connected at the Generator end only. 3. Check for proper installation of the RS485 cable between the Annunciator and the generator s control panel. Is this cable sharing a conduit or running next to any high voltage or high current electrical lines? 4. Use Generator Controller GenLink communication diagnostics to check if data is being sent or received via the Tx and Rx check boxes. Go to the pull-down menu for diagnostics and select Com Ports. Select the port the Annunciator is connected to (normally port 0) and look to see if the check boxes change state. If not, data is not being transmitted/received, check the cabling. If data is being received, check the baud rate settings of all connected equipment. 1. The RS485 Communications is not functioning. See items 1-4 above. 9

12 Part No. 0G6960 Revision C (09/14/09) Printed in U.S.A.

20 Light Remote Annunciator

20 Light Remote Annunciator Light Remote Annunciator Owner s Manual Surface Mount Flush Mount 94-95- Standard Annunciator 94-, 94-95-, 95-4- 4- Annunciator w/remote Relay Panel 4-, 4-4-, 4-49-, 49-49-, 49- Time Multiplexed Annunciator

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TT-1343 5/06b INSTALLATION INSTRUCTIONS Original Issue Date: 8/03 Model: Automatic Transfer Switches Equipped with Series 1000 Programmable Controller Market: ATS Subject: Remote Annunciator Kits GM28938-KP1,

More information

M2500 Engine Controller Installation Manual

M2500 Engine Controller Installation Manual M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...

More information

OPERATION / INSTALLATION

OPERATION / INSTALLATION OPERATION / INSTALLATION & PROGRAMMING MANUAL AFP-2800 LCD-80 Fire Alarm Panel Revision 1.01 November 16, 2004 NSW (Head Office) 7 Columbia Court Norwest Business Park Baulkham Hills NSW 2153 Ph: (02)

More information

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE General Description This guide provides a summary for installing and configuring the Centaur TM Cube Slave Alarm Signalling Equipment

More information

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117 Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel Revision E 61117 CAUTION: (Read This First) This panel has been designed to make it nearly bullet proof to mistakes made when wiring

More information

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B PRODUCT BULLETIN SB 8001B Type 8001 ALARM ANNUNCIATOR TYPE8001 FEATURES 16 or 32 alarm points per flush mount enclosure Displays are backlit with long life LEDs and engraved to suit Dimmer controls built

More information

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

LDM Series Lamp Driver Modules For Graphic Annunciation and Control 12 Clintonville Road Northford, CT 06472 (203) 484-7161 FAX: (203) 484-7118 LDM Series Lamp Driver Modules For Graphic Annunciation and Control Used with the System 500, System 5000, AM2020/AFP1010 and

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS www.altronicinc.com INSTALLATION INSTRUCTIONS WARNING: WARNING: DEVIATION DEVIATION FROM THESE FROM INSTRUCTIONS THESE INSTRUCTIONS MAY LEAD MAY TO IMPROPER LEAD TO OP- ERATION OF IMPROPER THE MACHINE

More information

Public Safety DAS Annunciator Panel

Public Safety DAS Annunciator Panel Public Safety DAS Annunciator Panel 120 VAC Models: 1221-A, 1221-B, 1221-C Revision D 91117 48 VDC Models: 1221-A-48, 1221-B-48, 1221-C-48 24 VDC Models: 1221A-24, 1221-B-24, 1221-C-24 CAUTION: (Read This

More information

ACCURATE ELECTRONICS INC

ACCURATE ELECTRONICS INC ACCURATE ELECTRONICS INC Page 1 of 7 Model 108078 2 Sept 09 WWW.ACCURATE.ORG PO BOX 1654 97075-1654 8687 SW Hall Blvd 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 Practice Section 108078 Rev A

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL The LeakMonitor alarm panel is a microprocessor controlled fully adjustable alarm system suitable for multizone

More information

ANNUNCIATOR FIXED MODULE

ANNUNCIATOR FIXED MODULE 12 Clintonville Road Northford, CT 06472 Phone: 203-484-7161 Fax: 203-484-7118 THE ANNUNCIATOR FIXED MODULE Installation Manual for the AFM-16ATF and AFM-32AF Annunciator Modules Document # 15970 3/27/95

More information

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option SM3000 Videographic Recorder User Guide (RTU) Communications Option ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow

More information

DGC-1000 DIGITAL GENSET CONTROLLER

DGC-1000 DIGITAL GENSET CONTROLLER DGC-1000 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-1000) offers a low cost microprocessor based integrated alternative for small to medium sized genset control and monitoring.

More information

USER MANUAL FOR OPERATING SYSTEM

USER MANUAL FOR OPERATING SYSTEM P2262 ALARM PANEL USER MANUAL FOR OPERATING SYSTEM 21765-07 September 1999 Associated Controls (Aust) PTY. LTD. 29 Smith Street, Hillsdale, NSW, 2036. PH (02) 9311 3255, FAX (02) 9311 3779 Page 1 of 177

More information

X11CA COMPUTER ANNUNCIATORS

X11CA COMPUTER ANNUNCIATORS S E R I E S XCA COMPUTER ANNUIATORS E N G I N E E R I N G C O M P A N Y The Ronan Series XCA Computer Annunciators are the latest generation of Ronan s state-of-the-art annunciators offered in window models.

More information

RS485 MODBUS Module 8AI

RS485 MODBUS Module 8AI Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

DGC-500 DIGITAL GENSET CONTROLLER

DGC-500 DIGITAL GENSET CONTROLLER DGC-500 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-500) offers a low cost microprocessor based integrated alternative for the control and monitoring of small to medium sized

More information

RMS/RPX Reader. User Manual

RMS/RPX Reader. User Manual RMS/RPX Reader User Manual Copyright Disclaimer Trademarks and patents Intended use FCC compliance Copyright 2005, GE Security Inc. All rights reserved. This document may not be copied or otherwise reproduced,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS www.altronicinc.com INSTALLATION INSTRUCTIONS WARNING: WARNING: DEVIATION DEVIATION FROM THESE FROM INSTRUCTIONS THESE INSTRUCTIONS MAY LEAD MAY TO IMPROPER LEAD TO OP- ERATION OF IMPROPER THE MACHINE

More information

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps TT-1023 1/97 INSTALLATION INSTRUCTIONS Original Issue Date: 2/94 Model: 6-2000 kw Market: Industrial Subject: Flush- or Surface-Mount Remote Annunciator Kits PA-293991 and PA-293991-SD The remote annunciator

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The nvent RAYCHEM NGC-40 is a multipoint

More information

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment. LED Driver Module Installation Guide 1.0 Notice These instructions are for installing Radionics LED Driver Module in a fire alarm system controlled by Radionics D8024 or D10024 Fire Alarm Control Panels

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The Raychem NGC-40 is a multipoint electronic

More information

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note Product Overview: The Pertronic F4 Remote LED Mimic / Aux Relay Module F4-RMAX is an optional extra for the Pertronic F4 conventional 4-zone fire alarm panel. This board enables the fire alarm panel to

More information

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014) AIS750 Series Alarm Annunciator User Manual (Ver 23 / JUNE 2014) 3-350 John Street, Thornhill, tario L3T 5W6 Phone: 289 597 APEX (2739) Fax: 289 597 2200 Toll Free: 1 866 776 2943 Email: mail@annunciatorca

More information

HRX Technical Manual. Version 1.2

HRX Technical Manual. Version 1.2 HRX 5000 Technical Manual Version 1.2 Contents: Specification...2 Connectors...5 RS-485 Network Connectors (J6 and J7)...5 RS-232 to Printer (J19)...6 RS-232 to PC (J8)...7 TCP/IP...8 Power (J21)...9 Fire

More information

Variable Frequency Drive SERIES MP800 VFD

Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controls and Accessories Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for

More information

Across-the-Line SERIES MP300 Combined Manual and Automatic

Across-the-Line SERIES MP300 Combined Manual and Automatic Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps

More information

P2267 NETWORK INTERFACE

P2267 NETWORK INTERFACE P2267 NETWORK INTERFACE USER MANUAL FOR OPERATING SYSTEMS: 22031-03 23636-01 October 2009 Associated Controls (Australia) Pty. Limited 2-4 Norfolk Road Greenacre, NSW, 2190. PH +61 2 9642 4922, FAX +61

More information

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

La Marche Manufacturing Company   Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual La Marche Manufacturing Company www.lamarchemfg.com Option 46 Series Digital Combined Accessory Package Installation and Operation Manual This manual is subject to change without notice. You may obtain

More information

Model A1700 Series Annunciator

Model A1700 Series Annunciator Seekirk Model A1700 Series Annunciator Applications: For usage in all types of process industries, electric generation, transmission and distribution, gas and water utilities. Features: The Seekirk model

More information

Flair 500 Series Annunciators

Flair 500 Series Annunciators Flair 500 Series s Basics Flair Multi-Zone s (MZAs) are fully functional, flexible, programmable micro controller based alarm control panels. They can be used independently d or in conjunction with other

More information

IF-L/RF Protection Switch

IF-L/RF Protection Switch Instruction Manual Model 1582-1152 IF-L/RF Protection Switch August 2014, Rev. 0 CH1 HISTORY ALARM LINE HISTORY RESET AUTO MANUAL SELECT CH2 HISTORY ALARM LINE RESET MANUAL REMOTE AUTO ALARM PS1 PS2 MODEL

More information

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX Page 1 of 10 Model 10807800 January 2014 ACCURATE ELECTRONICS INC PO BOX 1654 97075-1654 8687 SW HALL BLVD 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 WWW.ACCURATE.ORG Practice Section 10807800

More information

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET Instruction Manual Model 1582-125L 1:1 Switch February 2017, Rev. 0 CH1 HISTORY LINE HISTORY RESET AUTO MANUAL SELECT CH2 HISTORY LINE RESET MANUAL REMOTE AUTO PS1 PS2 MODEL 1582 CROSS TECHNOLOGIES INC.

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

Rig Protector. Multipoint Critical Gas Detection and Monitoring System Rig Protector Multipoint Critical Gas Detection and Monitoring System Rig Protection Device Protecting Personnel from Hazardous Gases RC Systems has engineered and manufactured industrial electronic products

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

PTE0705 Electric Fence Monitor

PTE0705 Electric Fence Monitor PTE0705 Electric Fence Monitor The JVA logo is a registered trademark of JVA Technologies. JVA Technologies. TABLE OF CONTENTS DESCRIPTION... 2 QUICK START GUIDE... 3 FEATURES... 4 EXPLANATION OF TERMS...

More information

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D ASCO 5350 The ASCO 5350 ATS Remote Annunciator is listed under the Underwriter s Laboratories Standard UL-1008 for Automatic Transfer Switch accessories. This stand-alone device provides individual status

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)

More information

Fratech Multipath-IP

Fratech Multipath-IP Rev 2.0 (May 2013) Installer Manual 1 Current Part Numbers: Fratech Multipath-IP E-Link STU PCB & Accessory Kit only In Metal Enclosure with Power Supply 998325-PK 998325-XS Installer Manual This document

More information

Soft Start Series MP700 Solid State, Reduced Voltage

Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s

More information

Model A2100 Series Annunciator

Model A2100 Series Annunciator Seekirk Model A2100 Series Annunciator Applications: For usage within transformers, switchgear, breakers and/or within any processing equipment or control room applications either attended or unattended

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

AIS750 Series Alarm Annunciator

AIS750 Series Alarm Annunciator Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual &

More information

ModBus DE-1 INSTALLATION AND USER MANUAL

ModBus DE-1 INSTALLATION AND USER MANUAL ModBus DE-1 INSTALLATION AND USER MANUAL INTESIS Software, SL Distributed by DURAN ELECTRONICA S.L Tomás Bretón 50 28045 MADRID, España duran@duranelectronica.com www.duranelectronica.com 2 2010 DURAN

More information

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08 GasScanner 4C Four Channel Monitor Operator s Manual MINT-0280-XX Rev. A 02/25/08 Product Warranty Matheson Tri-Gas., warrants gas alarm equipment sold by us to be free from defects in materials, workmanship,

More information

Macurco DVP-120 / DVP-120M Detection and Ventilation Control Panel User Instructions

Macurco DVP-120 / DVP-120M Detection and Ventilation Control Panel User Instructions Macurco DVP-120 / DVP-120M Detection and Ventilation Control Panel User Instructions IMPORTANT: Keep these User Instructions for reference. TABLE OF CONTENTS 1 Introduction 4 1.1 DVP-120 General Information

More information

UNC100 Integra Manual

UNC100 Integra Manual UNC100 Integra Manual New Generation Building Security July 30, 2014 V1.2 Copyright Notice Copyright 1995-2014 by All rights reserved Worldwide. Printed in Canada. This publication has been provided pursuant

More information

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual From urgent alarms to routine messages, the PD141AFO VIGILANTE handles all types of operational messages with simplicity and economy. The VIGILANTE

More information

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R Region Project Page 1 PART 1 - GENERAL 1.1 REFERENCES.1 CAN/ULC-S524-2006, Standard for the Installation of Fire Alarm Systems..2 CAN/ULC-S525-2007, Audible Signal Device for Fire Alarm Systems..3 CAN/ULC-S526-2007,

More information

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device Safety Instructions Used symbols Important Comments Before starting with installation of the MS 10B Alarm Unit, we recommend you to read the important information beneath. Qualification The installation

More information

Oxygen (O2) Single-Point Gas Detection System

Oxygen (O2) Single-Point Gas Detection System Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity

More information

VA301C CONTROLLER WITH BACnet OPTION

VA301C CONTROLLER WITH BACnet OPTION ORDERING INFORMATION VA301C Controller VA301C-DLC VA301C-DLC-BIP Gas detection controller with data logging, display and plastic housing. Gas detection controller with data logging and display, BACnet/IP

More information

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary

More information

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009 Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual Man-1048 Issue 05 October 2009 CONTENTS Contents... Page Safety & Installation...2 Installation - continued...3

More information

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels R 12 Clintonville Road, Northford, CT 06472 Phone: (203) 484-7161 FAX: (203) 484-7118 Instruction Manual for the MS-4012/4024 and CMS-4012/4024 Fire Alarm Control Panels Document 15586 5/11/93 Revision:

More information

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training PowerWizard Level 1.0 & Level 2.0 Control Systems Training New Systems Current Systems Systems Comparison Level 1 Level 2 Level 3 Level 4 PowerWizard Level 3.0 PowerWizard Level 4.0 Overview Common parts

More information

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes

More information

REPEATER FS5200R INSTRUCTION MANUAL

REPEATER FS5200R INSTRUCTION MANUAL REPEATER FS5200R INSTRUCTION MANUAL Instruction Manual Page1 CONTENTS 1. Introduction... 3 2. Function... 3 3. Technical data... 3 4. Contents of delivery... 4 5. General information... 5 6. Duty Mode...

More information

Cimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2

Cimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2 Series 21 - Specifications INDEX Description Page Operational Specification 2 Analog Operational Specification - Communications Options 3 Digital Operational Specification - Communications Options 4 Hardware

More information

ATS Annunciator - MODBUS

ATS Annunciator - MODBUS GE Zenith Controls ATS Annunciator - MODBUS Model 150047443 Quick Start Guide ATS Annunciator monitors and controls up to 8 Automatic Transfer Switches equipped with the MX150/250 Controller. Before getting

More information

System 9000TS Sequence of Events Recorder

System 9000TS Sequence of Events Recorder System 000TS Sequence of Events Recorder ms Event Recorder and combined Annunciator Modular, rack mounting design expandable to over 000 inputs ms time stamping of events across the whole system Up to,000

More information

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation PS6 SERIES Power Supplies PS6 SERIES Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation and Specifications Manual ISDPS6_SERIES 08121590 PCN15016 R05/15GR

More information

1 INTRODUCTION NOTICE WARNINGS AND CAUTIONS NATIONAL APPROVALS EMC COMPATIBILITY UNPACKING...

1 INTRODUCTION NOTICE WARNINGS AND CAUTIONS NATIONAL APPROVALS EMC COMPATIBILITY UNPACKING... ZXA / ZXE FIRE ALARM CONTROL PANEL MORLEY-IAS Table of Contents 1 INTRODUCTION...1 1.1 NOTICE... 1 1.2 WARNINGS AND CAUTIONS... 1 1.3 NATIONAL APPROVALS... 2 1.4 EMC COMPATIBILITY... 2 2 UNPACKING...3

More information

M1000 Alarm Annunciator

M1000 Alarm Annunciator Data Sheet Alarm Annunciator Reliable Supervision and Control 10 inputs with LED indications Supports both NO/NC input contacts 10 open collector outputs Built-in siren relay Text label for alarm descriptions

More information

RTD-10 Installation Instructions

RTD-10 Installation Instructions LED3 SW1 LED4 LED5 LED6 RTD-10 Installation Instructions +V S5 S6 POWER 15-24VDC English RTD-10 Installation Instructions 100.00 RTD-10 Control Interface realtime Control Systems 24VAC/3DC, 1A REMC P1

More information

ME 3011C / Alarm Indication / Quick Reference Guide

ME 3011C / Alarm Indication / Quick Reference Guide Tables of Contents Page Application 1 Features 1 Important Safety Information! 2 Note to this Guide 2 Further Information 2 Device Variants 2 General Functions 3 Annunciator Sequences - ISA 18.1 3 Plan

More information

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features. CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse

More information

HRX3000. Technical Manual

HRX3000. Technical Manual HRX3000 Technical Manual Contents: Specification...2 Connectors...3 Power (J21)...3 RS-485 Network Connectors (J6 and J7)...4 RS-232 to PC (J8)...5 Printer and Fire Alarm Panel (J19)...6 TCP/IP...8 Modem

More information

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum

More information

CTT8 TEMPERATURE MONITOR DEVICE

CTT8 TEMPERATURE MONITOR DEVICE INSTRUCTION MANUAL IM302-U v2.3 CTT8 TEMPERATURE MONITOR DEVICE GENERALITY The device of control temperatures CTT8 is used in the control of electric machine, transformer, motor, etc. where it s possible

More information

AN-3100D Annunciator

AN-3100D Annunciator AN-3100D Annunciator FOR POWER GENERATION, TRANSMISSION & DISTRIBUTION, PETROLEUM, PETROCHEMICAL, AND OTHER PROCESS INDUSTRIES INNOVATIVE ANNUNCIATOR Continuing with the widely successful AN-3100 series

More information

Installation, Operation, and Maintenance Instructions

Installation, Operation, and Maintenance Instructions Installation, Operation, and Maintenance Instructions MEGA 2 Medical Electronic Gas Alarm Andersen Medical Gas 12 Place Lafitte Madisonville, LA 70447 http://www.themedicalgas.com 1-866-288-3783 MAN 01-027

More information

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16 TraceTek TTSIM-1A TraceTek Sensor Interface Module with Relay Installation/OPERATION Instructions Approvals and Certifications TYPE NM General Signaling Equipment 76LJ Only AC versions are UL listed and

More information

FIRECLASS Networking. Addressable Fire Alarm Control Panels From Software version 21. Product Application and Design Information FC-A-FCNET-A

FIRECLASS Networking. Addressable Fire Alarm Control Panels From Software version 21. Product Application and Design Information FC-A-FCNET-A FIRECLASS Networking Addressable Fire Alarm Control Panels From Software version 21 Product Application and Design Information FC-A-FCNET-A Doc. version 1 23. March 2012 FIRECLASS. Hillcrest Business Park,

More information

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA CONVENTIONAL FIRE ALARM CONTROL UNITS MR-2300 SERIES Fire Alarm Control Units Description Secutron s MR-2300 Series fire alarm control panels consist of six and twelve zone models which are equipped with

More information

FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual

FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual Fire Safety FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual Siemens Building Technologies, Inc. Siemens Building Technologies, Ltd. 8 Fernwood Road 2 Kenview

More information

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm Operating & Maintenance Manual Alert-4 Ethernet LCD Master Alarm w w w. a m i c o. c o m Contents User Responsibility 4 Introduction 4 Features 5 Description of the Alarm 5 Shipment Details 5 The Alarm

More information

ESSEX ENGINEERING CORPORATION

ESSEX ENGINEERING CORPORATION WATER/WASTEWATER TREATMENT CONTROL SYSTEMS AND SUBSYSTEMS 2000 SERIES CONTROL SYSTEMS: 2000 series are for surface mounting inside a control cabinet Model 2024 Electronic Alternator Duplex (two pump) pump

More information

R A D I O N I C S. READYKEY K2015A Alarm Event Manager. Installation Data Sheet. Description

R A D I O N I C S. READYKEY K2015A Alarm Event Manager. Installation Data Sheet. Description R A D I O N I C S READYKEY K2015A Alarm Event Manager Installation Data Sheet READER CONTROLLER INPUTS INPUTS RLY 8 RLY 7 RLY 6 RLY 5 RLY 4 RLY 3 RLY 2 RLY 1 8 Supervised Inputs (Normally Open or Normally

More information

KT-100 Door Controller

KT-100 Door Controller WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully

More information

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08 Beacon 200 Gas Monitor Operator s Manual Part Number: 71-2102RK Released: 6/6/08 Table of Contents Chapter 1: Introduction.................................................3 Overview.............................................................3

More information

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power T M User Manual MarinaGuard Ground Fault Monitoring Panel For Marina Shore Power NAE1095810 / 03.2013 T M Bender Inc. USA: 700 Fox Chase Coatesville, PA 19320 Toll-Free: 800-356-4266 Phone: 610-383-9200

More information

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems Honeywell Life Safety Iberia C/Pau Vila 15-19; 08911 Badalona Barcelona T. 902 03 05 45; Internacional:+34932424236 www.honeywelllifesafety.es infohlsiberia@honeywell.com ibox Modbus Server Gateway for

More information

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS GENERAL INFORMATION Please read these instructions and keep them in a safe place. These instructions must

More information

PRYCO, INC. FUEL CONTROL

PRYCO, INC. FUEL CONTROL PRYCO, INC. FUEL CONTROL and MONITORING SYSTEM Page 1 DETAIL SPECIFICATIONS INTRODUCTION PRYCO s FUEL CONTROL and MONITORING (FCM) system is the most sophisticated and powerful control tool available for

More information

OVEN INDUSTRIES, INC.

OVEN INDUSTRIES, INC. OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and

More information

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description MODUL-R FIRE ALARM CONTROL PANELS MR-2900/MR-2920 Addressable Fire Alarm Control Panels Description MR-2900 Fire Alarm Control Panel The MR-2900 fire alarm system control unit is the heart of a sophisticated

More information

MODEL P531, P532 AND P532UI FLAME MONITOR OPERATING MANUAL

MODEL P531, P532 AND P532UI FLAME MONITOR OPERATING MANUAL MODEL P531, P532 AND P532UI FLAME MONITOR OPERATING MANUAL TABLE OF CONTENTS DESIGN FEATURES OVERVIEW... 1 Viewing Head Selection...1 USER INTERFACE OVERVIEW... 1 Default Settings...2 Numerical configuration...2

More information

Beacon 800 Gas Monitor Operator s Manual

Beacon 800 Gas Monitor Operator s Manual Beacon 800 Gas Monitor Operator s Manual Part Number: 71-0037RK Revision: F Released: 4/18/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to be

More information

600 Range Dialer Installation Manual. Version 1.0

600 Range Dialer Installation Manual. Version 1.0 600 Range Dialer Installation Manual Version 1.0 The information contained is supplied without liability for any errors or omissions. No part may be reproduced or used except as authorised by contract

More information

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.

More information

Instruction Manual Model Backup Switch, 1 for 8

Instruction Manual Model Backup Switch, 1 for 8 Instruction Manual Model 2582-282 Backup Switch, 1 for 8 December 2011, Rev. 0 MODEL 2582 SWITCH CROSS TECHNOLOGIES INC. SWITCH ALARM PSA PSB ALARM OFFLINE ONLINE UNIT STATUS 1 2 3 4 5 6 7 8 BU PROT MODE

More information

INTRODUCTION / TABLE OF CONTENTS

INTRODUCTION / TABLE OF CONTENTS 1 2 INTRODUCTION / TABLE OF CONTENTS Step One The LVCN 20 and LVCN 100 Series are general purpose level controllers offered in two configurations for pump and valve control. The LVCN 100 Series features

More information