Built-on speed controller

Size: px
Start display at page:

Download "Built-on speed controller"

Transcription

1 Air Comfort air comfort Centriflow 3D Plug fan GMPM, GMEB Built-on speed controller» Installation and Operation BUILT-ON FREQUENCY CONVERTER FW02 FOR CENTRIFLOW 3D PLUG FAN WITH PERMANENT MAGNET AND ASYNCHRONOUS MOTOR Content Page 1. Introduction Features Installation Functions Built-in protection Alarms Modbus Maintenance Troubleshooting Disposal Technical specification... 16

2 2 Installation and Operation 1. Introduction This frequency controller is used with permanent magnet synchronous motors (PM) or asynchronous motors (AC). Speed can be controlled with a 0-10 V DC signal, potentiometer, Modbus RTU or hand terminal. The hand terminal (PAN-08-0) is not automatically included in the delivery but can be ordered as an accessory. Main voltage requirement is 3-phase 400 VAC. Frequency controller is equipped with an EMC filter. Built-on means that the frequency controller is mounted at the side of the fan. If the fan service side is on the other side, the drive can easily be moved there by opening four screws. Cabling between motor and drive is already done. Built-on version is ready to be used and needs only power from mains and control signals. They can be easily connected to the terminals under the drive s plastic cover. 3. Installation 3.1. Mechanical installation The built-on frequency converter is factory mounted to left side of the fan (when looking from behind of the fan). If needed, the frequency converter can be removed to the right hand side of the fan according to the following instructions. Otherwise please use the cable tie (delivered with the fan) to attach the motor cable to the motor bracket/mounting plate, see point Frequency controller cooling ribs are in the air flow. Surplus heat is removed by active ventilation. 2. Features As standard, frequency controller has the following built-in features Modbus RTU 0-10 V analogue input for controlling speed Control via external hand terminal Indication relays for alarm and running Flying start Alarms for overload, over-voltage and under-voltage Motor and cable protector with built-in current limiter Short-circuit protection against phase to phase short circuiting on motor output terminals Digital input for Start/stop Digital input for Alarm reset or Fire mode Built-in EMC filter Automatic speed reduction in the event of over temperature inside the drive or lacking phase on the supply input Loosen the upper bolts and remove lower fixing bolts (M6) of the frequency converter mounting plate. You might need a 10 mm wrench with the upper front bolt. Upper bolt Lower bolt

3 Installation and Operation Slide off the mounting plate Put the upper bolts (removed from the left hand side) on their places on the right hand side of the motor bracket. Bolts shall be loose enough to get the mounting plate slided to its place. After that, attach lower bolts (also removed from the left hand side) and tighten all bolts Attach the cable tie to motor bracket / mounting plate Electrical installation Frequency converter must only be installed and commissioned by trained and qualified personnel. Incorrect electrical installation may cause risk of severe or fatal personal injury. If natural draught through the duct system causes the fan to rotate even when it has not received an operating signal, there is a risk that the motor will induce voltage on the frequency converter motor terminals, making them dangerous to touch Short circuit protection Correct short-circuit protection must always be used with the frequency converter in accordance with local and international regulations. Short-circuit protection is supplied by the installer Supplementary protection Direct earthing or TN or TT system earthing can be used for supplementary protection Frequency converter must always be supplementary protected with an earthing wire connected to the protective earth terminal (PE). If an RCD/HPFI (TT system) is used, it must be specifically intended for use with motor controllers Potential equalisation There is a risk of electrical interference if the ground potential between the frequency converter and the air handling unit or duct differ from each other. In the event of potential differences between system components, an equalisation conductor must always be fitted. Recommended cable cross section is 10 mm 2. Lugs should be used, and the equalisation conductor should be attached to the frequency converter enclosure via one of the screws used to mechanically install the unit Earth connection (PE) Frequency converter must be earthed in accordance with applicable local and international standards and directives. In power cable, please use an earthing lead which is suitable for the purpose. Frequency converter must be earthed singly and must therefore never be earthed in series. Keep earth connection wires as short as possible.

4 4 Installation and Operation Cable requirements All cables and leads used in connection with the frequency converter must comply with local and national rules and regulations. Shielded cable is not necessary for I/O and Modbus communication. Generally, cable types with copper wires are recommended. For recommended cable dimensions, see table 3.1 below Opening the frequency converter Check that the voltage supply to the frequency converter has been disconnected before opening the cover. Wait approx. 3 minutes after disconnecting mains voltage before removing the cover. Frequency converter is opened by loosening the six Torx20 screws holding the plastic cover in place. Carefully remove the loosened cover. Power Cable gland Cable diameter Cable size, min. Cable size, max. Core sleeve/stripped min. Power supply cable 1,5-3,0 kw M mm 4x1,5 mm² 4x2,5 mm² 10 mm 4,0-7,5 kw M mm 4x1,5 mm² 4x4 mm² mm 11, 15 kw M mm 4x2,5 mm² 4x10 mm² mm A/D control cable 1,5-15 kw M mm 2x2x0,7 mm² 10x2x0,7 mm² 10 mm Modbus round cable 1,5-15 kw M mm 3x2x0,7 mm² 10x2x0,7 mm² 10 mm Modbus round cable 1,5-15 kw Telecommunication cable/ribbon cable, 6-core, unshielded, 30 AWG/0,066 mm² Table Terminal and connector overview M V 50/60 Hz U V WPE BR BR + Alarm Relay 1 Running Relay 2 L1 L2 L3PE Hand terminal Motor 11 NC 12 C 13 N0 14 NC 15 C 16 N0 Supply Reset Start/Stop Modbus 01 Bus A 02 Bus B 03 GND VDC Vln 06 GND 07 Din2 08 Din1 09 Dout1 10 GND A B C

5 Installation and Operation Mains voltage connection 3~400V, 50Hz Connect power cable to terminals L1, L2, L3 and PE It is recommended that the PE wire is 20 mm longer than the other wires in the cable Remember to re-tighten the cable glands to ensure ingress protection and strain relief mm MAINS L1 L2 L3 PE Modbus connection Frequency converter is equipped with four connectors for Modbus connection. It also features 3 x RJ12 connectors and one strip of spring terminals. On the terminal strip with spring terminals for control signals (A/D I/O), the terminals for connecting Modbus are marked Bus A, Bus B and GND. If wanted, a round cable can be used for Modbus communication, connected to terminals marked Bus A and Bus B on the frequency converter terminal strip. The Modbus terminals are internally connected in parallel to the Modbus pins in the RJ12 connectors marked A and B. The three 3 RJ12 connectors are marked A, B and C. A : Modbus connection, slave, +24V voltage supply in connector. B : Modbus connection, slave, no voltage supply in connector. C : Modbus connection, master, external equipment, e.g. PTH/ VOC. A 6-core, unshielded, 30 AWG/0.066 mm² telecommunications cable or similar type of ribbon cable can also be used for Modbus communication. Attach RJ12 connectors to both ends by using a special-purpose tool. Bus A Bus B GND +10V DC Same colour sequence

6 6 Installation and Operation A/D control signal connections Connect A/D control signals to the terminal strips The function/programming of A/D inputs and outputs can be changed via Modbus. Digital inputs Din2 = Alarm reset (factory setting) Din1 = Start/Stop (factory setting) Potentiometer control +10VDC = Constant + 10VDC 0-10V In = Analogue 0-10V control input for speed o Potentiometer, electrical connection. (Potentiometer: min. 500 Ω, recommended 4.7 kω) GND = Ground (-) Digital output Dout1 = Alarm Out; Open Collector (factory setting) Max. pull-up voltage 24 V, max. current 20 ma External controller, electrical connection 0-10V In = Analogue 0-10V GND = Ground (-)

7 Installation and Operation 7 Relay outputs Relay output 1: Alarm Relay 1 (terminals 11, 12, 13) can be used to send an alarm signal to an external device. The signal output is a changeover relay which is closed between terminals 11 and 12 in idle position and otherwise closes between terminals 12 and 13. If the frequency converter has stopped due to a critical alarm, the relay will switch position and close between terminals 12 and 13. The relay is simultaneously opened between terminals 11 and 12. When the alarm is reset / acknowledged, the relay returns to its original position, closing between terminals 11 and 12. Max. 30VAC/24VDC/1A Alarm Relay 1 NC C NO NC Running Relay 2 C NO Relay output 2: Running indication Relay 2 (terminals 14, 15, 16) can be used to send an operating signal to an external device. The signal output is a changeover relay which is closed between terminals 14 and 15 in idle position and otherwise closes between terminals 15 and 16. When the frequency converter receives a start signal, the relay changes position, closing between terminals 15 and 16. The relay is simultaneously opened between terminals 14 and 15. When the start signal to frequency convert is removed, the relay returns to its starting position, closing between terminals 14 and Hand terminal (PAN-08) connection and functions The FWD-02 frequency converter can be connected to a PAN-08 hand terminal via Modbus RJ12 connector A. If a PAN-08 is connected, the hand terminal will act as master and the frequency converter as slave. Only one master at a time can be connected to the RJ12 connectors marked A and B. It is thus not possible to connect both a hand terminal to connector A and an active Modbus communication cable to connector B at the same time. PAN-08 has the following menu options: Status: Control and operating parameters for connected frequency converter Setup: Setting application parameters Alarm: Read-out of alarm log for connected frequency converter Modbus: Changing Modbus settings for frequency converter About: Read-out of software version no. and type for connected frequency converter Config: Changing frequency converter / motor settings

8 8 Installation and Operation 4. Functions Frequency controller can be controlled via: Analogue/digital (A/D) inputs Modbus RTU Local hand terminal PAN-08-0 Potentiometer The factory setting is Analogue/digital (A/D) control 4.1. Analogue/digital control Frequency/revolutions Max. Hz/Rpm Min. Hz/Rpm Max. Speed Min. Speed 0% 100% 0V 9.5V Speed out Setpoint 100% 0% Up ramp Down ramp Setpoint Frequency controller can be controlled by external input signals. Before the frequency controller can be started, it must be given a start/stop signal. It is given by short-circuiting terminals GND and Din1. Speed is controlled by connecting the control signal (0-10V DC) to terminals 0-10V In and GND. Relation between control signal (0-10 V In) and speed see fig. The control signal regulates motor speed between the set minimum and maximum speeds (AC motor = Hz; PM motor = rpm) Time Time 4.2. Modbus control Frequency converter can be controlled via Modbus commands according to the Modbus protocol. Control of motor speed via Modbus communication is factory disabled. If the ffrequency converter is to be controlled via Modbus, Coil Stat Bit register 8 must be set to 0 = Modbus control. Other functions, such as alarm read-out and acknowledgement, are still possible via Modbus even though Modbus control is not activated. See more detailed description of Modbus in chapter 7. Modbus Switching frequency Switching frequency is crucial in determining the amount of audible acoustic noise emitted by the frequency converter. The higher the switching frequency, the less audible noise will be emitted by the frequency converter. At the same time, however, internal losses will be increased, reducing efficiency. The frequency converter can be set to operate constantly with a switching frequency of either 4 khz or 8 khz, or it can be set to change switching frequency automatically depending on motor speed (AUTO setting). Switching frequency (switching mode) is set via Modbus: Setting 4kHz = Constant 4kHz switching frequency Setting 8kHz = Constant 8kHz switching frequency Setting AUTO = Switching frequency is changed automatically: At motor speeds higher than 70% of rated speed, switching frequency is changed to 4 khz At motor speeds lower than 60% of rated speed, switching frequency is changed to 8 khz 4.4. Fire mode Fire mode designates a function in which the frequency converter is kept operating by an emergency program which disables the alarm monitor. Among other things, the function can be used in connection with smoke extraction from a burning property. When fire mode is activated, an extraction fan will continue to remove smoke from the property for as long as possible. In fire mode, the frequency converter is able to maintain operation for at least an hour even when the frequency converter and the fan motor are overheated (max. 70 C). In fire mode, the overheating protection built into the frequency converter is disabled and the motor is not stopped if communication is lost. In fire mode, the fan is not stopped in case of faults or other alarms from either the fan or the frequency converter. Speed is controlled to the actual setting, determined by an external 0-10V signal, a potentiometer or via Modbus from a Modbus master controller. Fire mode can be activated via Modbus.

9 Installation and Operation 9 5. Built-in protection If the temperature inside frequency converter exceeds +95 C, the frequency converter will attempt to reduce its internal heat generation by reducing motor speed (rpm). Frequency converter has built-in current limitation for the protection of motor and cables and cannot therefore supply more current than it is set to. In the event of lacking phase on the supply input, the frequency converter will reduce speed and activate a non-critical alarm. The frequency converter motor output terminals are short circuit protected against phase-to-phase short circuiting. 6. Alarms Frequency converter has a built-in alarm monitor, which monitors optimal fault-free operation and triggers an alarm if operating or performance problems are observed. Alarms are either Critical alarms or Non-critical alarms. Critical alarms stop the motor. Non-critical alarms reduce motor performance. The built-in alarm monitor stops the frequency converter. If the alarm situation passes, the alarm is automatically reset and frequency converter restarted. If the maximum number of restarts (5 times/60 min) is exceeded, the alarm must be reset manually. The alarm can be reset by means of a Modbus command. The alarm is automatically reset if the power is disconnected for longer than 60 seconds. Alarms can be read via Modbus, see Modbus protocol. Alarm overview, see table 6.0 below Alarm overview Alarm Motor operation/ priority response Insufficient supply voltage NC RP Excessive supply voltage C SA5 Excessive power consumption by motor C SA5 Excessive temperature inside FWD-02 (> 95 C) NC RP Phase fault; one or more phases disconnected (L1, L2, L3) C SA5 Blocked motor C SA5 Motor current has reached its limit NC RP Internal hardware fault C SA5 Wrong direction of rotation C SA5 Fault in internal EEPROM circuit NC RP Stopped after 5 attempted restarts within 60 min C S Fault in braking chopper NC RP Phase fault on motor power supply (U, V, W) C SA5 Internal communication error C SA5 Excessive ripple voltage NC RP External 24VDC power supply overloaded NC RP Table 6.0 Abbreviations: C = Critical alarm NC = Non-critical alarm RP = Reduced performance SA5 = Motor stops after 5 restarts caused by same fault within 60 min S = Motor stops immediately LED indications Frequency converter is equipped with a two-colour LED which indicates operating status. The LED is located on the underside of the frequency converter beside the entry for the mains cable. LED lights constantly green when mains voltage is connected. LED flashes green when Modbus communication is active. LED lights constantly red when at least one critical alarm is active- LED flashes red when at least one non-critical alarm is active. 7. Modbus 7.1. Introduction This protocol contains the Modbus addresses and registers which are available in the frequency converter. Modbus can access single addresses or several addresses simultaneously, either by reading or writing 1-bit or 16-bit values. A Modbus address contains either a 1-bit value or a 16-bit integer. Values in this protocol are to be changed at your own risk. It is your own responsibility that changing of values and settings does not cause any overload or damage to the product, motor or fan Modbus register types: Modbus Type Description Reference Coil Status (R/W) Discrete Output 0x Input Status (R) Discrete Input 1x Input Register (R) 16-bit Input Register 3x Holding Register (R/W) 16-bit Output Register 4x R=Read only, R/W = Read/Write LED

10 10 Installation and Operation 7.3. Supported Modbus commands Function code Description 1 Read Coil Status 2 Read Input Status 3 Read Holding Registers 4 Read Input Registers 5 Force Single Coil 6 Preset Single Registers Diagnostics. Sub-function 00 Only - Return Query 8 Data (loop back). 15 Force Multiple Coils 16 Preset Multiple Registers 7.4. Modbus addressing Modbus addressing of frequency converter can be accomplished in three different ways. Via PC Tool by writing to Modbus Holding Register 4x0017 Via Hand Terminal, where frequency converter can be set to other Modbus addresses. Via the addressing pins of the A or B connectors see figure in chapter The addressing pins can be used to assign the frequency converter controls the address range: 0x36 (dec.54), 0x37 (dec.55), 0x38 (dec.56) and 0x39 (dec.57), see table below. Add. Oin no. Add. Pin1 Add. Pin2 0X36 (54 dec) 0X37 (55 dec) 0X38 (56 dec) 0X39 (57 dec) = No connection between GND and add. Pin1/Add. Pin 2 = Connection between GND and add. Pin1/Add. Pin Communication parameters Communication parameters can be set using the Hand Terminal or via a PC Tool. You can always connect frequency converter with these fixed values: Parameter Range Unit Factory setting Address n/a 54 dec Baud rate 9.600, , , bps Parity None, even, odd n/a None Stop bit(s) 0, 1, 2 n/a 1 Communication timeout Sec. 0 Table n/a = not applicable You can set alternate communication parameters to Holding registers 4x x0025. See table Coil Stat Bits - Available Coil Stat Bits are shown in the table below. Standard Modbus (RTU) Coil Stat Bits: 11 (R/W) 0x01: Read 0x05: Write Single Coil (NOTE: ON => output value = 0xFF00) 0x0F: Write Multiple Coils Register Address Function Range Active state 0x Motor ON/OFF = ON 0x Reset Alarms = Reset 0x Fire Mode = Active 0x Rotation = Clockwise 0x Disable V_Ripple = Disable protection 0x Control = Modbus 1 = 0-10 V 0x Autodetect = Enable communication 0x Analog start = Enable signal 0x Inverter analog = Invert speed input 0x Allow using = Allow FW field weakening 0x Allow using = Allow BC brake chopper 0x Allow using cooling fan = Allow fan 0x Undervoltage config. Table = UV value from CCF 1 = Fixed value for 3x230V

11 Installation and Operation 11 Input Stat Bits - Available input Stat Bits are shown in the table below: Input Stat Bits 24 (R), 0x02: Read Register Address Function Range Active state 1x V LO Alarm = Alarm 1x V HI Alarm = Alarm 1x I HI Alarm (Motor out short) = Alarm 1x Temperature high = Warning 1x Input phase error = Error 1x Rotor Blocked = Error 1x Limit = Warning 1x Internal HW Fault = Alarm 1x Rotor direction = Alarm 1x EEPROM Error = Warning 1x Internal Stop = Alarm (Stop) 1x Brake Chopper Fault = Warning 1x Motor Phase Error = Alarm 1x Communication error MOC = Alarm 1x V Ripple = Warning 1x Digital input = Hi 1x Digital Input = Hi 1x Ext. 24 V supply overload = Overload 1x MOC in bootloader = Alarm 1x Digital input 3 (IOM) = Hi 1x Digital input 4 (IOM) = Hi 1x Communication error (IOM) = Warning 1x Motor Overheat (IOM) = Alarm 1x Windmilling = Warning 1x Rotation OK = Rotation OK Table Input Registers - Available Input Registers are shown in the table below. Input Registers: 28 (R), 0x04: Read Register Address Function Range PM-motor AC-motor Resolution Unit Resolution Unit 3x Drive type 1000-? 1 n/a 1 n/a 3x AOC SW version 0 -? 0,01 n/a 0,01 n/a 3x MOC SW version 0 -? 0,01 n/a 0,01 n/a 3x PrcOut ,01 % 0,01 % 3x RPMOut RPM 0,01 Hz 3x Intern Temp ,01 C 0,01 C 3x V In V 1 V 3x I Out ma 1 ma 3x Power In W 1 W 3x I Ripple ma 1 ma 3x Operation minutes min 1 min 3x Operation days Days 1 Days 3x V Ripple V 1 V 3x Config. File Variant AA-ZZ 2 ASCII characters 2 ASCII characters 3x Config. File Version ,01 n/a 0,01 n/a 3x ExtermSet mv 1 mv 3x AOC SW Variant n/a n/a n/a n/a n/a 3x AOC Boot SW 0 -? 0,01 n/a 0,01 n/a 3x MOC Boot SW 0 -? 0,01 n/a 0,01 n/a 3x Motor config. Variant n/a 1 n/a 3x Motor config. Version ,01 n/a 0,01 n/a 3x Fan config. Variant n/a 1 n/a 3x Fan config. Version ,01 n/a 0,01 n/a 3x User Data Varioant n/a 1 n/a 3x User Data Version ,01 n/a 0,01 n/a 3x IOM SW version 0 -? 0,01 n/a 0,01 n/a 3x V DC Bus (Peak) V 1 V 3x V Motor (Peak) V 1 V Table 7.5.4

12 12 Installation and Operation Holding Registers Available Holding Registers are shown in the table below Holding Registers: 32 (R/W) 0x03: Read 0x06: Write Single 0x10: Write Multiple Register Address Function PM-motor AC-motor Range Resolution Unit Range Resolution Unit 4x Setpoint/PrcSet ,01 % ,01 % 4x Min. RPM 0 -? 1 RPM 0 -? 0,01 Hz 4x Max. RPM 0 -? 1 RPM 0 -? 0,01 Hz 4x UpRampTime Sec Sec. 4x DownRampTime Sec Sec. 4x Max I Out 0 -? 1 ma ma 4x I Out Alarm Limit n/a n/a n/a ma 0 Auto 0 Auto 4x Switch Mode 1 4 khz 1 4 khz 2 8 khz 2 8 khz 4x U minhz n/a n/a n/a 0 -? 1 V 4x Freq Umax n/a n/a n/a 0 -? 0,01 Hz 4x Auto SF Change ,01 % ,01 % 4x ExpSet n/a n/a n/a n/a 4x Drive Type ? 1 n/a n/a 4x Modbus ID n/a n/a 4x Number of retries n/a n/a 4x CommTimeout Sec Sec bps bps 4x CommRate bps bps bps bps bps bps 0 None n/a 0 None n/a 4x Parity 1 Odd n/a 1 n/a n/a 2 Even n/a 2 n/a n/a n/a INVALID n/a n/a INVALID n/a 4x Stop Bits 1 1 n/a 1 1 n/a 2 2 n/a 2 2 n/a n/a Disabled n/a n/a Disabled n/a 1 Start/Stop n/a 1 n/a n/a 2 AlarmReset n/a 2 n/a n/a 4x DigIn1 config 3 MB_IDs2 n/a 3 n/a n/a 4 Invert 10V n/a 4 n/a n/a 5 Rotation n/a 5 n/a n/a 6 Firemode n/a 6 n/a n/a 7 Motor Overheat n/a 7 n/a n/a n/a Disabled n/a n/a Disabled n/a 1 Start/Stop n/a 1 n/a n/a 2 AlarmReset n/a 2 n/a n/a 4x DigIn2 config 3 MB_IDs2 n/a 3 n/a n/a 4 Invert 10V n/a 4 n/a n/a 5 Rotation n/a 5 n/a n/a 6 Firemode n/a 6 n/a n/a 7 Motor Overheat n/a 7 n/a n/a 4x DigOut config 0 Disabled n/a n/a Disabled n/a 1 TachoOut n/a 1 n/a n/a 2 Running n/a 2 n/a n/a 3 AlarmOut n/a 3 n/a n/a 4x MotorConfigVar n/a n/a 4x FanConfigVar n/a n/a Table 7.5.5? = Value depends on hardware variant n/a = not applicable Continued on next page.

13 Installation and Operation 13 Holding Registers, Cont. Register Address Function PM-motor AC-motor Range Resolution Unit Range Resolution Unit 0 Disabled n/a 0 Disabled n/a 1 Start/Stop n/a 1 Start/Stop n/a 2 AlarmReset n/a 2 AlarmReset n/a 4x DigIn3 config (IOM) 3 Disabled n/a 3 Disabled n/a 4 Invert 10V n/a 4 Invert 10V n/a 5 Rotation n/a 5 Rotation n/a 6 Firemode n/a 6 Firemode n/a 0 Disabled n/a 0 Disabled n/a 1 Start/Stop n/a 1 Start/Stop n/a 2 AlarmReset n/a 2 AlarmReset n/a 4x DigIn4 config (IOM) 3 Disabled n/a 3 Disabled n/a 4 Invert 10V n/a 4 Invert 10V n/a 5 Rotation n/a 5 Rotation n/a 6 Firemode n/a 6 Firemode n/a 0 Disabled n/a 0 Disabled n/a 1 n/a n/a 1 n/a n/a 4x Relay 1 config (IOM) 2 Running start n/a 2 Running start n/a 3 Alarm out n/a 3 Alarm out n/a 4 Running spin n/a 4 Running spin n/a 0 Disabled n/a 0 Disabled n/a 1 n/a n/a 1 n/a n/a 4x Relay 2 config (IOM) 2 Running start n/a 2 Running start n/a 3 Alarm out n/a 3 Alarm out n/a 4 Running spin n/a 4 Running spin n/a 0 Disabled n/a 0 Disabled n/a 4x AnalogOut1 config (IOM) 1 ActSpeed n/a 1 ActSpeed n/a 2 TBD n/a 2 TBD n/a 0 Disabled n/a 0 Disabled n/a 4x Thermistor config (IOM) 1 Motor Overheat PTC n/a 1 Motor Overheat PTC n/a 2 TBD n/a 2 TBD n/a 0 Disabled n/a 0 Disabled n/a 4x AnalogIn2 config (IOM) 1 TBD n/a 1 TBD n/a 2 TBD n/a 2 TBD n/a 4x Thermistor treshold ohm ohm 4x Max Windmilling Time Sec Sec Table 7.5.5? = Value depends on hardware variant n/a = not applicable 8. Maintenance Frequency converter is maintenance free under normal operating conditions and load profiles. The cooling fins must be kept free of dust, dirt and other foreign matter so that air can pass freely over them. Deposits of dust, dirt or other foreign matter on and between the cooling fins will prevent cooling of the frequency converter and thus impair performance. The cooling fins may become very hot. (Max. +95 C under normal operating conditions) Frequency converter cannot be repaired on site. Never attempt to repair a defective unit. Contact your supplier to obtain a replacement. Additional technical data are available on request from Fläkt Woods Oy.

14 14 Installation and Operation 9. Troubleshooting Before opening the frequency converter, the mains voltage must be disconnected for at least 3 minutes to ensure there is no risk of dangerous residual currents in electronic circuits or capacitors. If natural draught through the duct system cause the fan to rotate even though it has received no operating signal, there is a risk that the motor will induce voltage on the frequency converter motor terminals, making them dangerous to touch. Troubleshooting when frequency converter is controlled via A/D signals: Symptom Cause Action Lacking supply voltage Check voltage 400V in frequency controller terminals L1, L2 and L3 Check whether short-circuit protection has been activated. Check that the voltage supply to frequency converter has not been cut off by other components. Poor electrical connections Check electrical connections Wrong motor for frequency converter setup Check that the correct motor settings have been read into and stored in the frequency converter setup. Lacking operating signal A/D control: Short-circuit frequency controller terminals Din 1 (START) and GND Motor inoperative No 0-10 V DC control signal Check that 0-10 VDC signal is connected correctly to frequency controller terminals 0-10Vin and GND With potentiometer control : Check that the potentiometer is connected correctly to frequency controller terminals +10V dc, 0-10V In and GND. Active alarm Read out active alarms and remedy their cause. The motor has been stopped by the built-in motor protector 5 times because of overload or other alarm. Reset the alarm by short-circuiting frequency controller terminals DIn 2 and GND. The alarm can also be reset by disconnecting the power supply to the frequency controller and reconnecting it after approx. 60 seconds Defective frequency controller Replace frequency controller. Never attempt to repair a defective frequency controller. Contact your supplier for replacement/repair. Defective motor Replace motor Motor running in wrong direction Wrong phase sequence in motor cable Interchange two phase wires on the motor or the frequency converter terminal strip. Motor is noisier than acceptable Switching frequency too low Increase switching frequency 0 = Auto (factory setting), 1 = Low = 4 khz, 2 = High = 8 khz Raising the switching frequency increases energy losses in frequency controller. Switching frequency can be changed using the Hand Terminal. Frequency controller cuts out due to an alarm. At least one alarm active The alarm is re-activated after reset Use Hand Terminal to view the alarm and determine which alarm has stopped the controller/motor. Reset the alarm by short-circuiting frequency controller terminals DIn 2 and GND. The alarm can also be reset by disconnecting the power supply to the frequency controller and reconnecting it after approx. 60 seconds. Use Hand Terminal or PC Tool to view the alarm and determine which alarm has stopped the controller/motor. Remedy the cause of repeated alarm activation.

15 Installation and Operation 15 Troubleshooting when speed is controlled by Modbus Symptom Cause Action Lacking supply voltage Check voltage 400V in frequency controller terminals L1, L2 and L3 Check whether short-circuit protection has been activated. Check that the voltage supply to frequency converter has not been cut off by other components. Poor electrical connections Check electrical connections Wrong motor for frequency converter setup Check that the correct motor settings have been read into and stored in the frequency converter setup. Lacking operating signal Check that the frequency converter can receive an operating signal. Coil Stat Bits Register 0X0001: Motor start/stop (1=On). Motor inoperative Check the Modbus control signal at Modbus address: Lacking % control signal from Modbus controller Holding registers; Register 3X0001: PrcSet (0-100%). Motor running in wrong direction Motor is noisier than acceptable Frequency controller cuts out due to an alarm The motor has been stopped by the built-in motor protector 5 times because of overloading Defective frequency controller Defective motor Wrong phase sequence in motor cable Switching frequency too low At least one alarm active The alarm is re-activated after reset Reset alarm: Coil Stat Bits Register 0X0002: Reset (1 pulse = Reset). The alarm can also be reset by disconnecting the power supply to the frequency converter and reconnecting it after approx. 60 seconds. Replace frequency controller. Never attempt to repair a defective frequency controller. Contact your supplier for replacement/repair. Replace motor Interchange two phase wires on the motor or the frequency converter terminal strip. Increase switching frequency. 0 = Auto 1 = Low = 4 khz 2 = High = 8 khz Increasing switching frequency increases losses within frequency converter, thus reducing efficiency. Frequency converter switching frequency can be changed via Hand Terminal or via Modbus. Use Hand Terminal to view the alarm and determine which alarm has stopped the controller/motor. Reset the alarm by short-circuiting frequency controller terminals DIn 2 and GND. The alarm can also be reset by disconnecting the power supply to the frequency controller and reconnecting it after approx. 60 seconds. Read out the alarm via Modbus registers and determine which alarm has stopped the controller/motor. Remedy the cause of repeated alarm activation. 10. Disposal Frequency converter contains electronic components and must not be disposed of together with household waste. Frequency converter must be disposed of in accordance with applicable local rules and regulations. Frequency converter meets the requirements on marking of electronic waste contained in the European WEEE Directive 2012/19/EU.

16 16 Installation and Operation 11. Technical specification Speed controller Power size kw Efficiency % > 96.5 Power supply Voltage VAC 3 x 400 VAC 50/60 Hz +/-10% Supply current at max. load A Power factor at max. load cos-phi φ > 0.9 Motor output Max output voltage Vrms 3 x VAC Max output current Arms Protection Max. fuse A 16 Motor output Short-circuit protected between phases Motor Protected by current limit Impulse protection Protected against transient voltages by VDR Over-voltage protection Yes. 565 V Overload protection Current and temperature overload protection Enviroment Operating temperature C -40 C to +50 C Starting temperature C -40 C to +50 C Storage temperature C -40 C to +70 C Dimensions mm 185 x 250 x 100 mm 220 x 295 x 110 mm Protection rating IP Enclosure material Aluminium Front cover Plastic Weight kg Humidity % rh 10-95% rh. non-condensing Vibration Stationary: IEC Class 3M6 2.0 Kg Non-stationary: IEC Class 3M Kg Air flow / cooling > 3 m/s full power mounted inside air stream no need for on-board fan < 3 m/s derated output power typically mounted outside direct air stream on-board fan can be added Interfaces Digital communication MODBUS RTU RS485 (baud rate: Kbaud) Digital communication Slave 2 x RJ12 & 2 x spring terminals Digital communication Master 1 x RJ12 connection Analogue In VDC, 9.5 V DC +/-2% Analogue Out1 +10 VDC Digital In1 Start/stop with internal pull-up Digital In2 Alarm res Digital Out1 Alarm signal Relay 1 Alarm signal Relay 2 Running indication Green LED Lit: Power connected Flashing: Active communication Red LED Flashing: Alarm but still running Constantly lit: Critical alarm - stop motor

17 Installation and Operation 17 Features Technology Sinusoidal back-emf signal controlled via FOC (Field Oriented Control) Flying start Yes. typically below 30% of max. speed depending on load and fan weight Ramp-up time sec Ramp-down time sec Alarm Yes Alarm reset Via digital input. Modbus or powering down for more than 60 seconds Fan stop sec. The braking system stops the fan as quickly as possible. Braking time will depend on the inertia of the fan. Service data log Operating hours, alarms, loads, software version, max. temp., max. motor voltage, max. motor current, max. ripple voltage, max. ripple current Software updating Yes, via serial interface Motor parameters Preprogrammed by Fläkt Woods Oy or on-site configuration Fire mode Nominal power for 1 hour at 70 C ambient temperature Field weakening Yes Short-circuit protection Yes EMC filter Integrated Approvals EMC EMC EN (C1 and C2) Safety EN Product standard EN Part 2 RoHS Directive Yes Product approvals CE Data are valid at nominal supply votage, temperature +25 C and sufficient air flow.

18 FWG-OEM Fans Installation & Operation-GB GB Copyright 2016 Fläkt Woods Group Centriflow 3D 9757GB A history of innovation and reliability Fläkt Woods is a global leader in air management. We specialize in the design and manufacturing of a wide range of air climate and air movement solutions. Our product brands such as SEMCO, eq, eq PRIME, Econet, Veloduct, Optivent, Econovent and Cleanvent are well-known and trusted by customers all over the world to deliver Air Comfort and Fire Safety. We are constantly aiming to provide systems that precisely deliver required function and performance, as well as maximum energy efficiency. Manufacturer: Fläkt Woods Oy Kalevantie 39, FI Turku, Finland Tel info@flaktwoods.com

PLUG FAN GMPM, GMEB BUILT-ON SPEED CONTROLLER

PLUG FAN GMPM, GMEB BUILT-ON SPEED CONTROLLER PLUG FAN GMPM, GMEB BUILT-ON SPEED CONTROLLER INSTALLATION AND OPERATION BUILT-ON FREQUENCY CONVERTER FW02 FOR CENTRIFLOW 3D PLUG FAN WITH PERMANENT MAGNET AND ASYNCHRONOUS MOTOR CONTENT PAGE 1. Introduction...

More information

FLÄkT WOOdS BuILT-ON FrEQuENCY CONVErTEr CENTRIFLOW 3D PLUG FAN WITH PERMANENT MAGNET AND ASYNCHRONOUS MOTOR

FLÄkT WOOdS BuILT-ON FrEQuENCY CONVErTEr CENTRIFLOW 3D PLUG FAN WITH PERMANENT MAGNET AND ASYNCHRONOUS MOTOR AIR COMFORT AIR TREATMENT 9932 GB 2016.10.28 FLÄkT WOOdS BuILT-ON FrEQuENCY CONVErTEr CENTRIFLOW 3D PLUG FAN WITH PERMANENT MAGNET AND ASYNCHRONOUS MOTOR» INSTALLATION, MAINTENANCE AND COMMISSIONING INTrOduCTION

More information

Built-on speed controller for GMPM plug fan with permanent magnet motor

Built-on speed controller for GMPM plug fan with permanent magnet motor Air Comfort air comfort Centriflow 3D Plug fan GMPM Built-on speed controller» Installation and Operation Built-on speed controller for GMPM plug fan with permanent magnet motor Content Page 1. Introduction...

More information

Instructions OJ EC-Controller (Translation of the original) BA-ESR_OJ-EC /2013

Instructions OJ EC-Controller (Translation of the original) BA-ESR_OJ-EC /2013 Instructions OJ EC-Controller (Translation of the original) EN BA-ESR_OJ-EC 1.0 02/2013 Contents Contents... 2 1. Revision Index... 2 2. Introduction... 3 3. Features... 4 4. Installation... 4 5. Operation...

More information

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.

More information

Operating Instruction NI-DV Controller (Original) BA-ESR_NI-DV /2015

Operating Instruction NI-DV Controller (Original) BA-ESR_NI-DV /2015 Operating Instruction NI-DV Controller (Original) EN BA-ESR_NI-DV 1.0 11/2015 Contents Contents... EN-2 1. Revision Index... EN-2 2. General... EN-3 3. Installation... EN-9 4. Operation... EN-20 5. Functions...

More information

Instructions for the fan motor control system, SILVER C

Instructions for the fan motor control system, SILVER C Instructions for the fan motor control system, SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units. The motor control system is

More information

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C 1. General The hand-held micro terminal is used for setting the motor parameters of the SILVER C. 2. Installation

More information

INSTRUCTIONS OJ-DV. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS C 12/16 (OSH) 2016 OJ Electronics A/S

INSTRUCTIONS OJ-DV. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS C 12/16 (OSH) 2016 OJ Electronics A/S INSTRUCTIONS OJ-DV 67393C 12/16 (OSH) 2016 OJ Electronics A/S OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS INSTRUCTIONS OJ-DV Contents 1. Product presentation...3 2. Introduction...3

More information

INSTRUCTIONS OJ-DV. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS D 12/17 (PDJ) 2017 OJ Electronics A/S

INSTRUCTIONS OJ-DV. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS D 12/17 (PDJ) 2017 OJ Electronics A/S INSTRUCTIONS OJ-DV 67393D 12/17 (PDJ) 2017 OJ Electronics A/S OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS INSTRUCTIONS OJ-DV Contents 1. Product presentation...3 2. Introduction...3

More information

INSTRUCTIONS. OJ-DV-Relay-Module. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. Optional module for OJ-DV motor controller

INSTRUCTIONS. OJ-DV-Relay-Module. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. Optional module for OJ-DV motor controller INSTRUCTIONS OJ-DV-Relay-Module 67439B 10/16 (OSH) 016 OJ Electronics A/S Optional module for OJ-DV motor controller OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS Contents 1. Product

More information

CENTRIFLOW 3D. >> Installation and Maintenance. air comfort. CentriFlow 3D

CENTRIFLOW 3D. >> Installation and Maintenance. air comfort. CentriFlow 3D CENTRIFLOW 3D Plug fan GMEC >> Installation and Maintenance air comfort CentriFlow 3D 2 Plug Fan CentriFlow 3D GMEC Installation and Maintenance Important Information, Safety notes, Technical Description

More information

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes 50-120 1 General The heat exchanger control system is a control system for 380 W step motors

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

RS485 MODBUS Module 8AI

RS485 MODBUS Module 8AI Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

MODBUS RS485. » Technical instructions. Air Comfort. Housing ventilation

MODBUS RS485. » Technical instructions. Air Comfort. Housing ventilation Air Comfort Air Treatment Housing ventilation MODBUS RS485» Technical instructions 2 Modbus RS485 Technical instructions Description, Connections, Presentation, decimals Description RS485 has two connections,

More information

DMFPM-2R MULTIFUNCTIONAL

DMFPM-2R MULTIFUNCTIONAL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND

More information

M2500 Engine Controller Installation Manual

M2500 Engine Controller Installation Manual M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...

More information

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans Air Comfort Air movement Duct & Box Fans GLEB KITCHEN exhaust FAN >> Installation and Maintenance Kitchen Exhaust Fan GLEB Installation and Maintenance Important Information, Safety notes, Technical Description

More information

GLEC exhaust FAN. Air Comfort. Air movement. Duct & Box Fans

GLEC exhaust FAN. Air Comfort. Air movement. Duct & Box Fans Air Comfort Air movement Duct & Box Fans GLEC exhaust FAN» Technical CATALOUGE Technical catalouge Exhaust Fan GLEC 2 Contents Exhaust fan - GLEC... 3 Performance Data...4 Fan chart-explanation and definitions...

More information

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1- DPR-45 User Manual V-2.0 (2..206) DPR-45 TEMPERATURE PROTECTION RELAY PT00 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT 9-50VDC SUPPLY DESCRIPTION DPR-45 is a precision unit designed for the temperature

More information

M1000 Alarm Annunciator

M1000 Alarm Annunciator Data Sheet Alarm Annunciator Reliable Supervision and Control 10 inputs with LED indications Supports both NO/NC input contacts 10 open collector outputs Built-in siren relay Text label for alarm descriptions

More information

RSGD. Three phase AC motor soft starter. Benefits. Description

RSGD. Three phase AC motor soft starter. Benefits. Description Three phase AC motor soft starter Description Benefits Easy to use. The is equipped with a self-learning algorithm that automatically adjusts the start parameters to optimise the motor starts and stops.

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

Series Digital Controller Instruction Sheet

Series Digital Controller Instruction Sheet 216/3/11 Series Digital Controller Instruction Sheet Thank you very much for purchasing DELTA DTC Series Temperature Controller. Please read this instruction sheet before using your DTC series to ensure

More information

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number Innovation In and Out of Parlour Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual Version - 1.0 Date - June 2016 Part Number - 39-0038 Index Manual Version... 3 About the Remote Vacuum

More information

Table of Contents SECTION PAGE

Table of Contents SECTION PAGE Table of Contents SECTION PAGE SECTION 1 INTRODUCTION................... 1.1 Description.............................. 1.2 Features................................ 1.3 Models.................................

More information

21-light Remote Annunciator. Owner s Manual

21-light Remote Annunciator. Owner s Manual 21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With

More information

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option SM3000 Videographic Recorder User Guide (RTU) Communications Option ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow

More information

Danfoss gas detection unit Type GD Heavy Duty

Danfoss gas detection unit Type GD Heavy Duty Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

USER MANUAL FOR OPERATING SYSTEM

USER MANUAL FOR OPERATING SYSTEM P2262 ALARM PANEL USER MANUAL FOR OPERATING SYSTEM 21765-07 September 1999 Associated Controls (Aust) PTY. LTD. 29 Smith Street, Hillsdale, NSW, 2036. PH (02) 9311 3255, FAX (02) 9311 3779 Page 1 of 177

More information

P2267 NETWORK INTERFACE

P2267 NETWORK INTERFACE P2267 NETWORK INTERFACE USER MANUAL FOR OPERATING SYSTEMS: 22031-03 23636-01 October 2009 Associated Controls (Australia) Pty. Limited 2-4 Norfolk Road Greenacre, NSW, 2190. PH +61 2 9642 4922, FAX +61

More information

CTT8 TEMPERATURE MONITOR DEVICE

CTT8 TEMPERATURE MONITOR DEVICE INSTRUCTION MANUAL IM302-U v2.3 CTT8 TEMPERATURE MONITOR DEVICE GENERALITY The device of control temperatures CTT8 is used in the control of electric machine, transformer, motor, etc. where it s possible

More information

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE General Description This guide provides a summary for installing and configuring the Centaur TM Cube Slave Alarm Signalling Equipment

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The nvent RAYCHEM NGC-40 is a multipoint

More information

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS.  A4741 / Rev.1 DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS User Manual and Menu Map A4741 / Rev.1 www.entes.com.tr ATTENTION -Disconnect all power before connecting the device. -Don t remove

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The Raychem NGC-40 is a multipoint electronic

More information

M2000 Engine Controller

M2000 Engine Controller M2000 Engine Controller Integrated control and protection of diesel and gas engines for all purposes Especially suited for auxiliary generator sets 1 IN OPERATION 1 2 STARTFAIL 2 3 OVERSPEED RPM FAIL 3

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English Rectifier RC-series Manual RC-series English Manual Wall and 19 English Presentation The RC-series is a rectifier for either directly powering the load or for use together with batteries. It is designed

More information

MO n : 12JMC rév A

MO n : 12JMC rév A CTT8 MO n : rév A Page 2 / 18 MODIFICATIONS Rev. Description Date Checked by Approuved by Z Creation 2012/02/12 JMC LA A First issue 2012/02/14 JMC LA INDEX Page 3 / 18 GENERALITY 4 INTRODUCTION 4 ACCESSORIES

More information

RSMFM-2R MULTIFUNCTIONAL

RSMFM-2R MULTIFUNCTIONAL MULTIFUNCTIONAL ROOM Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL

More information

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min

More information

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1 Lodam Compressor Protection Module Technical manual Version 3.0 SE-G1 Contents 1. Read this first... 4 1.1. Reading instructions... 4 1.2. User manual... 4 1.3. Safety... 4 2. General... 5 3. Definitions...

More information

Insulation fault evaluator EDS460-DG

Insulation fault evaluator EDS460-DG Insulation fault evaluator for localising insulation faults in DC IT systems with a number of branch circuits where high system leakage capacitances are involved Preliminary data sheet TDB108021en/09.2008

More information

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS... SECTION Table of Contents SECTION 1 INTRODUCTION...................... 1.1 Description............................... 1.2 Features................................. 1.3 Models..................................

More information

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Process & TeMPerATUre UniversAl input DigiTAl MeTers Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min

More information

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features. CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse

More information

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1 NGC-40 Bridge Overview Raychem-AR-H58862-NGC40BridgeOV-EN-1805 nvent.com 1 Table of Contents 1. NGC-40 Overview... 9 1.1 Example NGC-40 System... 10 2. Legal stuff... 11 3. Protocols... 12 3.1 Data es...

More information

recooler HP EQKR HEAT PUMP

recooler HP EQKR HEAT PUMP AIR COMFORT AIR TREATMENT 9566 GB 2016.03.17 recooler HP EQKR HEAT PUMP» TECHNICAL CATALOGUE 2 ReCooler HP EQKR Technical Catalogue Content ReCOOLER HP EQKR HEAT PUMP 3 product presentation. 3 applications.

More information

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances _D00108_00_D_XXEN/05.2015 ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances

More information

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491 Bender Incorporated 700 Fox Chase, Coatesville PA 1930 Tel.: (800) 356-466 Fax: (610) 383-7100 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control function

More information

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491 Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 06401 807-0 Fax: 06401 807-59 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control

More information

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05 Sierra Model 951 Digital Flo-Box Instruction Manual Part Number IM-951 Revision A 09-05 5 Harris Court, Building L Monterey, CA 93940 (831) 373-0200 (800) 866-0200 Fax (831) 373-4402 www.sierrainstruments.com

More information

On the job around the clock 24/7: Fire detection systems

On the job around the clock 24/7: Fire detection systems On the job around the clock 24/7: Fire detection systems Version 02.2010 Version: 02.2010 Product catalogue Fire detection systems This product catalogue is intended for sales purposes only. For planning,

More information

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas User s Manual TIGER S EYE E-Series Mark V Jockey TIGERFLOW Systems, Inc. 4034 Mint Way Dallas, Texas 75237 214-337-8780 www.tigerflow.com TABLE OF CONTENTS Introduction... 4 Sequence of Operation... 5

More information

Part 3 Troubleshooting

Part 3 Troubleshooting Part Troubleshooting What is in this part? This part contains the following chapters: Chapter See page Troubleshooting 2 Error Codes: Hydro-box 7 Error Codes: Outdoor Units Error Codes: System Malfunctions

More information

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15 with coupling device AGH675-7 and AGH675-7MV15 Device combination for insulation monitoring in unearthed AC, AC/DC and DC power systems (IT systems) IRDH275BM-7_D00123_03_D_XXEN/01.2017 with coupling device

More information

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev. TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL Microener- Copyright 2010 FW 2.1 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection

More information

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description Three phase AC pumps and ventilators soft starter Description Benefits Easy to use. The is equipped with a self-learning algorithm that automatically adjusts the start parameters to optimise the motor

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Phone: 040 807-0 Fax: 040 807-259 Alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC display

More information

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

LINEAR HEAT DETECTION CABLE DURÁN-SAFE LINEAR HEAT DETECTION CABLE DURÁN-SAFE Installation & User Manual 2018 DURAN ELECTRONICA S.L. - All rights reserved www.duranelectronica.com I-manSAFECABLE-v05 TABLE OF CONTENTS Pages 1. INTRODUCTION...

More information

Operating Manual MS220DA

Operating Manual MS220DA ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße 13, D 74523 Schwäbisch Hall + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA Mains Monitoring Digital Panel Meters MINIPAN

More information

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems) ISOSCAN EDS460/490 EDS461/491 Insulation fault locators with control and display function for EDS systems (insulation fault location systems) EDS460-490_D00085_01_D_XXEN/01.2017 ISOSCAN EDS460/490 EDS461/491

More information

Operating Manual MS220KA and MSR220KA

Operating Manual MS220KA and MSR220KA Temperature Relays and MINIKA, Mains Monitoring, Digital Panel meters MINIPAN, Switching Relays and Controls Operating Manual MS220KA and MSR220KA ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße

More information

BLAUAIR AUTOMATIC CONTROL SYSTEM

BLAUAIR AUTOMATIC CONTROL SYSTEM BLAUAIR AUTOMATIC CONTROL SYSTEM S30 (KVENT, TH-TUNE) S31 (KVENT) S32 (KVENT, PGDE) EN USER S MANUAL CONTENTS Safety requirements... 3 Purpose... 4 Technical data... 5 Installation and set-up... 6 Control...

More information

Remote alarm indicator and test combination MK2430

Remote alarm indicator and test combination MK2430 Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Tel.: 040 807-0 Fax: 040 807-259 Remote alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC

More information

CU 300. Installation and operating instructions GRUNDFOS INSTRUCTIONS

CU 300. Installation and operating instructions GRUNDFOS INSTRUCTIONS GRUNDFOS STRUCTIONS CU 300 Installation and operating instructions No contact Overvoltage Undervoltage Dry running Speed reduction Overtemperature Overload Sensor alarm Other languages www.grundfos.com/cu300-manual

More information

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com FL500 Modbus Communication Operating Manual Order No.: 10193214/00 MSAsafety.com 1000 Cranberry Woods Drive Cranberry Township, PA 16066 A Phone 1-800-MSA-2222 Fax 1-800-967-0398 For your local MSA contacts

More information

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems RCMA420_D00059_01_D_XXEN/06.2016 LINETRAXX RCMA420 Residual current monitor for monitoring AC,

More information

Series Temperature Controller Instruction Sheet

Series Temperature Controller Instruction Sheet Series Temperature Controller Instruction Sheet Thank you very much for purchasing DELTA A Series. Please read this instruction sheet before using your A series to ensure proper operation and please keep

More information

RS Pro Infrared Temperature Sensor

RS Pro Infrared Temperature Sensor Instruction Manual RS Pro Infrared Temperature Sensor Stock Number: 161-8103 Introduction The RS Pro Infrared Temperature Sensor is a device for measuring the temperature of the surface of a solid or liquid

More information

ME 3011C / Alarm Indication / Quick Reference Guide

ME 3011C / Alarm Indication / Quick Reference Guide Tables of Contents Page Application 1 Features 1 Important Safety Information! 2 Note to this Guide 2 Further Information 2 Device Variants 2 General Functions 3 Annunciator Sequences - ISA 18.1 3 Plan

More information

System 57. An advanced World of intelligent gas detection system management

System 57. An advanced World of intelligent gas detection system management An advanced World of intelligent gas detection system management A World of control technology High precision, intelligent control Master / voted alarm options High packing density Flexible I/O configuration

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments OMC-158-2 Ex interface unit Manual Version 1.2 August 2017 Author: Observator Instruments Revisions: 0.1 (October 2016) First issue 0.2 (December 2016) Prototype 0.3 (January 2017) Test release 1.0 (March

More information

OWNER S OPERATION MANUAL

OWNER S OPERATION MANUAL DUTY P P STDBY Run 1 2 Run STDBY P P FAULT Run 3 4 OK: Change mode PUMPCONTROL OWNER S OPERATION MANUAL Advanced Multi Pump Controller Installation and Operating Instructions MODEL: FPC-15607-S AUTO: RUNNING

More information

EXD-HP1/2 Stand-alone Superheat/Economizer Controller

EXD-HP1/2 Stand-alone Superheat/Economizer Controller Technical Bulletin EXD-HP1/2 are stand-alone universal superheat and or economizer controllers for heat pumps, heating units, air conditioning and precision cooling such as telecom and shelter applications.

More information

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

EBC20. Instructions for fitting, installation and operation. Read and save these instructions! EBC20 UK Instructions for fitting, installation and operation Read and save these instructions! 2 3002878 EBC20 UK 290415 1. Product information............................................... 4 1.1 Delivery.............................................................

More information

User Guide IM/L160_6. Wall-/Pipe-mount Level Indicator L160

User Guide IM/L160_6. Wall-/Pipe-mount Level Indicator L160 User Guide IM/L160_6 Wall-/Pipe-mount Level Indicator L160 Electrical Safety This equipment complies with the requirements of CEI/IEC 61010-1:2001-2 'Safety Requirements for Electrical Equipment for Measurement,

More information

Alarms Manual. ver.1 rev.06/'07. Enclosures to Service Manuals of: McbNET Digital TM Magnum400 TM MiniMagnum400 TM. 6) Speeder One

Alarms Manual. ver.1 rev.06/'07. Enclosures to Service Manuals of: McbNET Digital TM Magnum400 TM MiniMagnum400 TM. 6) Speeder One 6) Speeder One VIALE STAZIONE 5-36054 MONTEBELLO VIC. - VI - ITALY Phone (+39) 0444 440441 - Fax (+39) 04444 440418 www.axorindustries.com - INFO@AXORINDUSTRIES.COM Alarms Manual Enclosures to Service

More information

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION 968 AFMS AFMS TECHNICAL SPECIFICATION 08/07 Ref B ATV-ELEKTRONIK GMBH WIENER STRASSE 228 A-4030 LINZ +43 732 301600 FAX. +43 732 301600 21 Page 2 Table of contents General Introduction...3 Overview...3

More information

CLEANROOM MONITOR CR3A Network - Installation Instructions

CLEANROOM MONITOR CR3A Network - Installation Instructions CLEANROOM MONITOR CR3A Network - Installation Instructions INTRODUCTION The CR3 Series Cleanroom Monitor, was developed specifically to allow for monitoring of confined spaces with accuracy and reliability.

More information

S304 and S305 Dust Emission Monitors. User Manual. Distributor

S304 and S305 Dust Emission Monitors. User Manual. Distributor S304 and S305 Dust Emission Monitors User Manual Distributor Version 6.4 30/5/2012 Table of Contents 1. INTRODUCTION... 3 1.1 Safety... 3 1.2 Product overview... 4 1.3 Principle of operation... 4 2. INSTALLATION...

More information

HPS-C-MULTI 6. Hotrunner Controllers. Operating manual. Valid for item numbers:

HPS-C-MULTI 6. Hotrunner Controllers. Operating manual. Valid for item numbers: Valid for item numbers: HPS-C-MULTI 6: 69010.306 (6-zone) 69010.312 (12-zone) 69010.324 (24-zone) 69010.336 (36-zone) HPS-C-MULTI 6 Hotrunner Controllers Operating manual HPS-C-MULTI 6 with WIRE TEST (WT):

More information

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit PRODUCT INSTRUCTIONS Fire Door Control Panel (FDCP) Floats Rd, Wythenshawe, Manchester. M23 9WB T: 44 (0)161 945 4561 F: 44 (0)161 945 4566 Stock Code Description Doc No: PI115 00133 00134 Ellard Fire

More information

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT User's Manual Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput Types) Thank you for purchasing the JUXTA Signal Conditioner. Please read through this

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS XXXXXXX-0 EN 1904 READ AND SAVE THESE INSTRUCTIONS BASIC-PLC CONTROLLER MANUAL For all Condair desiccant dryer with equipped with Basic- PLC valid from version: PLC-35/PLC-45 18.04.03 Dehumidification

More information

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 505 Grünberg Tel.: 060 807-0 Fax: 060 807-59 A-ISOMETER IRDH575 Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with

More information

Analog Annunciator Unit SACO 16 A3. Product Guide

Analog Annunciator Unit SACO 16 A3. Product Guide Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Powerful, flexible and field-customizable 16-channel analog input signal annunciator unit A full

More information

Interface and EOL Modules 8

Interface and EOL Modules 8 Interface and EOL Modules Interface Modules Series 420 25 Interface Modules Series 100 291 EOL Modules 293 254 Interface and EOL Modules Interface Modules Series 420 Interface Modules Serie 420 Interface

More information

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB Summary 1 CONNECTIONS... 3 1.1 TEMPERATURE PROBES...3 1.2 LOW VOLTAGE DIGITAL INPUTS...3 1.3 LIVE DIGITAL INPUTS...4 1.4 RELAY OUTPUTS...5 2 POWER SUPPLY... 6 3 SERIAL CONNECTIONS... 6 4 SOFTWARE... 7

More information

SUPERINTEND VRE-08/16/32/64

SUPERINTEND VRE-08/16/32/64 SUPERINTEND VRE-08/16/32/64 Residual Current Monitoring System (RCM) for Grounded Electrical Systems 8/16/32/64 supervision points Operator Manual v2.00 Superintend VRE-08/16/32/64 operator manual v2.00

More information

20 Light Remote Annunciator

20 Light Remote Annunciator Light Remote Annunciator Owner s Manual Surface Mount Flush Mount 94-95- Standard Annunciator 94-, 94-95-, 95-4- 4- Annunciator w/remote Relay Panel 4-, 4-4-, 4-49-, 49-49-, 49- Time Multiplexed Annunciator

More information

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems Honeywell Life Safety Iberia C/Pau Vila 15-19; 08911 Badalona Barcelona T. 902 03 05 45; Internacional:+34932424236 www.honeywelllifesafety.es infohlsiberia@honeywell.com ibox Modbus Server Gateway for

More information

Symmetra MW Modbus Data Points

Symmetra MW Modbus Data Points Symmetra MW Modbus Data Points Version 0.11.19.05 rev 1 General Information: There are two devices that constitute the Symmetra MW system: the UPS and the EBS. There is a separate point mapping for each

More information

F4 Process Controller Installation and Operation Guide

F4 Process Controller Installation and Operation Guide F4 Process Controller Installation and Operation Guide 1.Introduction 1.1.Highlight Features Space saving, only 55mm panel depth required Higher sampling rate (1mS) results in better control performance

More information