TFI Report Reaction to fire test

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "TFI Report Reaction to fire test"

Transcription

1 TFI Report Reaction to fire test For the classification according to EN :2010 Customer GÜLSEVEN HALI GÜLSEVEN TEKSTIL KIMYA GIDA SAN. TIC. LTD. STI Ahi Evran Sanayi Sitesi Istiklal Caddesi No: Demirci/Manisa TURKEY Product textile floor covering ELITE Responsible at TFI Dipl.-Ing. Ulrike Balg Tel: Aachen, 29 May 2015 This report includes 2 pages and 3 annexes. This report is a transcription of test report no The present document is provided with a qualified electronic signature and is valid without autograph signature. This report only applies to the tested specimens and has been established to the best of our knowledge. Only the entire report shall be reproduced. Under no circumstances, extracts shall be used. Furthermore, we apply the General Terms and Conditions for the Execution of Contracts of the Textiles & Flooring Institute GmbH, also with regard to the order execution.

2 Transaction Test order Order date 22 April 2015, 29 May 2015 Your reference Product designation Reaction to fire test for construction products according to EN ISO :2010 B. Gülseven ELITE TFI sample number Date of manufacture not specified Date of sample receipt 04 May 2015 Sampling performed by 2 Product Specification cf. annex KT 3 Results Customer Burning behaviour using a radiant heat source according to EN ISO :2010 Average critical heat flux [kw/m²] 7.9 Integrated smoke density [% x min] 44 Adhesion Substrate according to EN 13238:2010 none fibre cement board This test report is the basis for a classification report according to EN :2010. The test results relate to the behaviour of the test specimens of a construction product under the particular conditions of the test; they are not intended to be the sole criterion for assessing the potential fire hazard of the construction product in use. 4 Annexes Photographs F Characteristics of the construction product a KT Reaction to Fire a RP The annexes marked a are based on tests accredited in accordance with EN ISO/IEC Page 2 of 2

3 F Annex F - Photographs 1 Transaction Product designation ELITE TFI sample number Testing period 27 May Test Method / Requirements -not specified- 3 Results 3.1. Specimen 1, in production direction 3.2. Specimen 2, in production direction Page 1 of 2

4 F Specimen 3, in production direction 3.4. Specimen 4, cross production direction Page 2 of 2

5 KT Annex KT Characteristics of the construction product 1 Transaction Product designation ELITE TFI sample number Testing period 26 May Test Method / Requirements ISO 1765:1986 ISO 8543:1998 Deviation Machine-made textile floor coverings Determination of thickness Textile floor coverings Methods for determination of mass Indication of mean values instead of individual results 3 Results Parameter Manufacturer's data TFI results Type of manufacture woven woven Type of surface cut pile cut pile Backing woven textile backing (jute and polyester cotton compound) finish Pattern - none - multicoloured, patterned Colour - none - blue, beige, red, dark blue Use surface 100 % wool not tested Type of delivery broad loom broad loom Total thickness [mm] Thickness of pile above the substrate [mm] 12 not tested Total mass per unit area [g/m²] 4200 ± 5 % 4043 CV= 0.6 % CV=Coefficient of Variation Page 1 of 1

6 RP Annex RP Reaction to Fire 1 Transaction Product designation ELITE TFI sample number Testing period 27 May Test Method / Requirements EN ISO :2010 Part 1 Determination of the burning behaviour using a radiant heat source Substrate according to EN 13238:2010 Fibre cement board Adhesion - none - Joint according to EN ISO :2010 No Conditioning Conditioning to constant mass according to EN 13238:2010 Deviation - none - 3 Results cf page 2-5 Page 1 of 5

7 RP (page 2 of 5) Annex RP - Burning behaviour Sample designation Sample Sample No.: 1 Direction: in production direction Observation molten/singed during pre-radiation up to 210 mm buckled/contracted from pilot flame area up to 0 mm penetration of flame through substrate - transitory flaming - blistering - glowing, after flame has extinguished - Results Position Time Heat Flow [mm] [min:s] [kw/m²] 50 02: : : : : Time Position Heat Flow [min:s] [mm] [kw/m²] 10: : : [%] Smoke density Zeit [min] CHF [kw/m²] 7.74 HF_30 [kw/m²] 0.00 Smoke density integral [%*min] 47.5 Flame extinguished after [min:s] 12:02 max. burnt distance [mm] 275 max. light attantuation [%] 23.0

8 RP (page 3 of 5) Annex RP - Burning behaviour Sample designation Sample Sample No.: 2 Direction: in production direction Observation molten/singed during pre-radiation up to 210 mm buckled/contracted from pilot flame area up to 0 mm penetration of flame through substrate - transitory flaming - blistering - glowing, after flame has extinguished - Results Position Time Heat Flow [mm] [min:s] [kw/m²] 50 02: : : : : Time Position Heat Flow [min:s] [mm] [kw/m²] 10: : : [%] Smoke density Zeit [min] CHF [kw/m²] 8.03 HF_30 [kw/m²] 0.00 Smoke density integral [%*min] 46.8 Flame extinguished after [min:s] 12:54 max. burnt distance [mm] 262 max. light attantuation [%] 24.3

9 RP (page 4 of 5) Annex RP - Burning behaviour Sample designation Sample Sample No.: 3 Direction: in production direction Observation molten/singed during pre-radiation up to 210 mm buckled/contracted from pilot flame area up to 0 mm penetration of flame through substrate - transitory flaming - blistering - glowing, after flame has extinguished - Results Position Time Heat Flow [mm] [min:s] [kw/m²] 50 02: : : : : Time Position Heat Flow [min:s] [mm] [kw/m²] 10: : : [%] Smoke density Zeit [min] CHF [kw/m²] 8.14 HF_30 [kw/m²] 0.00 Smoke density integral [%*min] 38.8 Flame extinguished after [min:s] 12:32 max. burnt distance [mm] 257 max. light attantuation [%] 21.7

10 RP (page 5 of 5) Annex RP - Burning behaviour Sample designation Sample Sample No.: 1 Direction: cross production direction Observation molten/singed during pre-radiation up to 210 mm buckled/contracted from pilot flame area up to 0 mm penetration of flame through substrate - transitory flaming - blistering - glowing, after flame has extinguished - Results Position Time Heat Flow [mm] [min:s] [kw/m²] 50 02: : : : : Time Position Heat Flow [min:s] [mm] [kw/m²] 10: : : [%] Smoke density Zeit [min] CHF [kw/m²] 7.81 HF_30 [kw/m²] 0.00 Smoke density integral [%*min] 45.5 Flame extinguished after [min:s] 13:16 max. burnt distance [mm] 272 max. light attantuation [%] 23.7

BS EN ISO : 2010

BS EN ISO : 2010 Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS EN ISO 92391: 2010 Fire Tests For Determination

More information

Analysis Report

Analysis Report Forbo Flooring Coral nv Dhr. Jan van Galen Postbus 17 1560 AA KROMMENIE Nederland Your notice of Your reference Date 08-02-2016 23-02-2016 Analysis Report 16.00634.08 Required tests : Identification number

More information

BS EN ISO : 2010

BS EN ISO : 2010 Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS EN ISO 92391: 2010 Fire Tests For Determination

More information

Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002

Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002 Efectis Nederland BV Efectis Nederland report 2008-Efectis-R0431[Rev.1](E) Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002

More information

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009 P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com CLASSIFICATION CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE

More information

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877. Return address: P.O. box 337, 7500 AH Enschede, TNO Centre for Textile Research Ariënsplein 3 7511 JX ENSCHEDE Forbo Flooring Attn. Mr. A. Tijhof Postbus 13 1560 AA Krommenie Report Sponsor : Contractor,

More information

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor: IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2 Smoke & Toxicity Test WF Report Number: 166040 Date: 13 th August 2007 Test Sponsor: Fiba Tech Industries Ltd. 0249 Page 2 of 13 Bodycote warringtonfire

More information

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009 P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification

More information

Reaction to fire classification report No C

Reaction to fire classification report No C Reaction to fire classification report. 17911C Owner of the classification report Tapetex B.V. Distributor: Vescom bv Churchilllaan 10 Sint Jozefstraat 20 5705 BK Helmond 5750 AB Deurne The Netherlands

More information

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier Page 1 of 27 Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier Test Sponsor Saveguard (UK) Limited Warrington Fire Research Centre Ltd.,

More information

Reaction to fire classification report No C-rev.1

Reaction to fire classification report No C-rev.1 Reaction to fire classification report. 17241C-rev.1 Owner of the classification report Distributor: Vescom bv Churchilllaan 10 Sint Jozefstraat 20 5705 BK Helmond 5750 AB Deurne The Netherlands The Netherlands

More information

Classification of Fire Performance of Wall and Ceiling Lining Materials

Classification of Fire Performance of Wall and Ceiling Lining Materials Classification of Fire Performance of Wall and Ceiling Lining Materials Using the Method of Kokkala, Thomas and Karlsson Reference: Kokkala, M.A. Thomas, P.H. and Karlsson, B. Rate of Heat Release and

More information

Fire Testing of Foams

Fire Testing of Foams Fire Testing of Foams The following Technical Information Pamphlet (TIP) examines Fire/Flammability Standards relevant to Cross-linked Polyethylene (XLPE) and Ethylene Vinyl Acetate containing foams. Introduction

More information

REACTION TO FIRE TESTS FOR BUILDING PRODUCTS DETERMINATION OF THE HEAT OF COMBUSTION ACCORDING TO STN EN ISO 1716: 2003

REACTION TO FIRE TESTS FOR BUILDING PRODUCTS DETERMINATION OF THE HEAT OF COMBUSTION ACCORDING TO STN EN ISO 1716: 2003 mgr. Dušan BERNÁT Fire and Research Institute Ministry of Interior of the Slovak Republic REACTION TO FIRE TESTS FOR BUILDING PRODUCTS DETERMINATION OF THE HEAT OF COMBUSTION ACCORDING TO STN EN ISO 1716:

More information

NF X : Parts 1, 2, 3, 4 & 5

NF X : Parts 1, 2, 3, 4 & 5 Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com NF X 10-702: Parts 1, 2, 3, 4 & 5 Fire test

More information

Contact person Date Reference Page Richard Johansson P (2) Fire Research

Contact person Date Reference Page Richard Johansson P (2) Fire Research issued by an Accredited Testing Laboratory Contact person Richard Johansson 215-8-13 5P4413 1 (2) Fire Research +46 1 516 56 75 richard.johansson@sp.se 12 ISO/IEC 1725 Sklejka-Pisz Paged S.A Ul. kwiatowa

More information

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Ad-hoc IEC 60331-2 x Ad-hoc investigation

More information

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5 INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5 5 Tech Notes TESTING PROTOCOL Fire Retardant Gel Coats Issue Date: 4/22/2010 Document ID: TN-TS-05A 2010 Interplastic Corporation Testing Protocol

More information

European Technical Assessment ETA-14/0176

European Technical Assessment ETA-14/0176 British Board of Agrément Bucknalls Lane Watford Herts WD25 9BA Tel: + 44 (0) 1923 665300 Fax: + 44 (0) 1923 665301 e-mail: mail@bba.star.co.uk website: www.bbacerts.co.uk Designated according to Article

More information

ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process

ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process 2010 IMO FTP Code Revisions Parts 2, 5, 7, 8, 9 & 10 Presented by: Juan Manuel Flores, P.E. Date:

More information

CAN/ULC-S102 Surface Burning Characteristics of "Digitally Printed Aluminum Siding" Coated Aluminum

CAN/ULC-S102 Surface Burning Characteristics of Digitally Printed Aluminum Siding Coated Aluminum UNCONTROLLED ELECTRONIC COPY CAN/ULC-S12 Surface Burning Characteristics of "Digitally Printed Aluminum Siding" Coated Aluminum A Report To: DiZal inc. 12 rue Bouvier, Suite 4 Québec, QC G2K K9 Phone:

More information

BS 476: Part 6: 1989+A1:2009

BS 476: Part 6: 1989+A1:2009 Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS 476: Part 6: 1989+A1:2009 Method Of Test

More information

CAN/ULC-S102 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel"

CAN/ULC-S102 Surface Burning Characteristics of 8 mm Fire Rated High Pressure Laminate Phenolic Panel ELECTRONIC DRAFT COPY CAN/ULC-S12 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel" A Report To: ABET Corporation 5 Paxman Road, Unit 1 Toronto, Ontario M9C 1B7

More information

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Ad-hoc IEC 60331-2 x Ad-hoc investigation

More information

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions. Method of test defined in IEC 60331-21 for determining the circuit integrity performance of a cable under fire conditions. WF Report Number: 148371 Test Sponsor: FTC - Fabbrica Trentina Conduttori Srl

More information

In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by. Norman Alvares & Harry Hasegawa

In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by. Norman Alvares & Harry Hasegawa In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by Norman Alvares & Harry Hasegawa First Paragraph of E-691 Tests performed on presumably identical materials in presumably

More information

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D PL 17819 01 00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 29.06.2017 to 10.08.2019 Holder of certificate: MPA

More information

MFPA Leipzig GmbH Prüf-, Überwachungs- und Zertifizierungsstelle für Baustoffe, Bauprodukte und Bausysteme

MFPA Leipzig GmbH Prüf-, Überwachungs- und Zertifizierungsstelle für Baustoffe, Bauprodukte und Bausysteme Prüf-, Überwachungs- und Zertifizierungsstelle für Baustoffe, Bauprodukte und Bausysteme Geschäftsbereich III - Dr.-lng. Peter ause Arbeitsgruppe 3.1 - Brandverhalten von Bauprodukten Mathias Claus Telefon

More information

Report Classification Report on Burning Behaviour

Report Classification Report on Burning Behaviour Report 65596 Classification Report on Burning Behaviour Applicant WESELER TEPPICH GMBH & CO.KG Emmelsumer Strasse 218 46485 Wesel DEUTSCHLAND Reference Hr. van Soest Application Classification of burning

More information

Fire Test Methods ASTM NFPA UL ISO IEC

Fire Test Methods ASTM NFPA UL ISO IEC Fire Test Methods ASTM NFPA UL ISO IEC D2859 (Standard Test Method for Ignition Characteristics of Finished Textile Floor Covering Materials) E84 (Standard Test Method for Surface Burning Characteristics

More information

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped) In accordance with: BS EN 8524-1 BS EN 1634-1 BS 5234-2 BS EN 14600 BS EN 13501-2 BS EN ISO 1716 BS EN 13501-1+A1 BS EN ISO 14184-1 BS EN 12101 10 BS ISO 21927 9 Period of Fire Resistance: 180 minutes

More information

Fire Safety Fire Resistant Building Components

Fire Safety Fire Resistant Building Components Fire Safety Fire Resistant Building Components NBN 713-020 1968 Fire fighting - Fire performance of building materials and products - Fire resistance of building materials NBN 713-020/A1 1982 Protection

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SGS GOVMARK TESTING SERVICES, INC. 96 Allen Boulevard, Suite D Farmingdale, NY 11735 Doug Lipp Phone: 631 293 8944 THERMAL Valid To: May 31, 2018 Certificate

More information

Report Test Report

Report Test Report ÖTI Institut für Ökologie, Technik und Innovation GmbH Report 70384 Test Report Applicant Camira Fabrics Ltd Meltham Mills, HD94AY Huddersfield GROSSBRITANNIEN Reference Mr. Daniel Young Application Determination

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-11035-03-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 25.10.2017 to 24.10.2022 Holder of certificate: DMT

More information

UL MATERIAL YELLOW CARD GRILON ANNEX Material certificates : Background information and classification information acc. to EN 45545-2 The European standard EN 45545-2 classifies the requirements for fire

More information

gent warn nfire No, 16209C Reaction to fire class ification report lntroduction Owner of the classification report

gent warn nfire No, 16209C Reaction to fire class ification report lntroduction Owner of the classification report a warn nfire global safety gent Reaction to fire class ification report No, 16209C Owner of the classification report TAPETEX bv VESCOM bv (Distributor) Churchilllaan 10 Sint-Jozefstraat 20 5705 BK Helmond

More information

Loss Prevention Standard

Loss Prevention Standard Loss Prevention Standard LPS 1196: Issue 1.2 This Loss Prevention Standard is the property of BRE Global Ltd. and is made publicly available for information purposes only. Its use for testing, assessment,

More information

CLASSIFICATION IN REGARD OF REACTION TO FIRE according to EN :2007

CLASSIFICATION IN REGARD OF REACTION TO FIRE according to EN :2007 SWORN TRANSLATOR & INTERPRETER OF THE ENGLISH LANGUAGE Provincial Court Gdansk, Poland EWA KOCIK 7/9 Czubinskiego Street 80-215 Gdansk tel. (48) 58 345 50 76, (48) 509 209 454 logo : Certified translation

More information

FIRE TESTING OF LOW SLOPE ROOF ASSEMBLIES AN INTERNATIONAL REVIEW

FIRE TESTING OF LOW SLOPE ROOF ASSEMBLIES AN INTERNATIONAL REVIEW FIRE TESTING OF LOW SLOPE ROOF ASSEMBLIES AN INTERNATIONAL REVIEW Birgitte Messerschmidt Rockwool International A/S Denmark & John Scott Roxul Inc. Canada ABSTRACT Knowing the fire behaviour of roofs is

More information

Modula Standard Performance

Modula Standard Performance the future of space conditioning Modula Standard Performance heating panel Application Commercial, hospitals, hotels, schools, shops, sports halls, offices, laboratories, food industry etc. Installation

More information

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): Dry cleaning (length shrinkage): 1% Pilling: Certificates / tests:

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): Dry cleaning (length shrinkage): 1% Pilling: Certificates / tests: LORD III Dense curtain fabric; Mottled basic article in Trevira CS. Lord III captivates with a soft drape quality and a textured surface. The hardwearing fabric with good sound absorption can be used for

More information

SPIDER P SPIDER P mineral

SPIDER P SPIDER P mineral The leader in the selfadhesive technology! SPIDER P SPIDER P mineral SPIDER P and SPIDER P MINERAL are excellent quality self-adhesive waterproofing membranes made with ADESO technology, the new compound

More information

BUSHFIRE TEST ON GLAZED VERTICAL ELEMENTS

BUSHFIRE TEST ON GLAZED VERTICAL ELEMENTS BUSHFIRE TEST ON GLAZED VERTICAL ELEMENTS Report number FSZ 1572 CSIRO job number SV3559 Date of issue 22 FEBRUARY 2013 Client BREEZWAY AUSTRALIA PTY LTD Commercial-in-confidence Copyright CSIRO 2013 Copying

More information

UL 94 Flammability Ratings: Introduction

UL 94 Flammability Ratings: Introduction UL 94 Flammability Ratings: Introduction UL intends this standard to serve as a preliminary indication of a plastics acceptability for use as part of a device or appliance with respect to its flammability.

More information

Construction Products Directive

Construction Products Directive Construction Products Directive Evaluation of conformity of Coated glass to he N 1096-4 ( September 2006) G E P V P, T H E E U R O P E A N A S S O C I AT I O N O F F L AT G L A S S M A N U FA C T U R E

More information

CATALYTIC EMITTER - An old idea in new clothes

CATALYTIC EMITTER - An old idea in new clothes Page: 1 CATALYTIC EMITTER - An old idea in new clothes 1. Physical Basis There are three kinds to transfer heat: conduction, convection and radiation. In case of conduction the heat is transferred from

More information

ASSESSMENT REVIEW. Review of Assessment Report WFRA C91415

ASSESSMENT REVIEW. Review of Assessment Report WFRA C91415 ASSESSMENT REVIEW Review of Assessment Report WFRA C91415 Fire resistance performance of steel electrical wall boxes mounted in plasterboard partitions with modified mounting arrangements, box design and

More information

Fine, semi-transparent curtain fabric in a high-class linen quality with an extremely soft feel and a light sheen. Can be combined with Lavanta.

Fine, semi-transparent curtain fabric in a high-class linen quality with an extremely soft feel and a light sheen. Can be combined with Lavanta. LENTA Fine, semi-transparent curtain fabric in a high-class linen quality with an extremely soft feel and a light sheen. Can be combined with Lavanta. Use: Semi-transparent curtain fabric Number of colours:

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Presley House Presley Way Crownhill Milton Keynes MK8 0ES United Kingdom Contact: Jeremy Hodge Tel: +44 (0) 1908 267300 Fax: +44 (0) 1908

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 11551 Second edition 2003-12-01 Optics and optical instruments Lasers and laser-related equipment Test method for absorptance of optical laser components Optique et instruments

More information

2.2 Factors in design

2.2 Factors in design 2.2 Factors in design 2.2.1 Structural application (load-bearing) 2.2.1.1 Loading conditions Before embarking on the design of a construction or part of a construction the designer must be in possession

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION IEC TS 62885-1 Edition 1.0 2016-08 Surface cleaning appliances Part 1: General requirements on test material and test equipment INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 97.080

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): Certificates / tests:

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): Certificates / tests: RADAR Curtain fabric in Trevira CS; The high tech look of the mesh fabric is manufactured using the classic filet technique. The filament yarn gives the item an understated and contemporary look. Radar

More information

Steam Station IRSG Portable DVD Player

Steam Station IRSG Portable DVD Player Steam Station IRSG2416 7 Portable DVD Player To reduce the risk of fire, injury or electrical shock: Read all the instructions before operating the pump station and keep them for future reference. If you

More information

C-01 FIRE DECKS AND BULKHEADS

C-01 FIRE DECKS AND BULKHEADS Guideline No.: C-01(201510) C-01 FIRE DECKS AND BULKHEADS Issued date: October 20,2015 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection

More information

High Capacity Hot Air Dryer

High Capacity Hot Air Dryer High Capacity Hot Air Dryer MADE IN AUSTRIA autumn 2015 www.zimmer-austria.com page 1 Hot air dryer type: Compact HC The modular construction of the high efficiency and powerful hot air nozzle dryer is

More information

ISO INTERNATIONAL STANDARD. Protective gloves for firefighters Laboratory test methods and performance requirements

ISO INTERNATIONAL STANDARD. Protective gloves for firefighters Laboratory test methods and performance requirements INTERNATIONAL STANDARD ISO 15383 First edition 2001-09-01 Corrected version 2003-04-15 Protective gloves for firefighters Laboratory test methods and performance requirements Gants de protection pour sapeurs-pompiers

More information

CONFIRMATION of Product Conformity (QAL1)

CONFIRMATION of Product Conformity (QAL1) CONFIRMATION of Product Conformity (QAL1) AMS designation: Manufacturer: Test Laboratory: Fidas 200 S, Fidas 200 and Fidas 200 E for suspended particulate matter PM 10 and PM 2,5 PALAS GmbH Greschbachstraße

More information

CONTINUOUS GEOMEMBRANES FOR ON SITE APPLICATION. PDA Europe 2012 Annual Conference Istanbul, November

CONTINUOUS GEOMEMBRANES FOR ON SITE APPLICATION. PDA Europe 2012 Annual Conference Istanbul, November POLYMERIC GEOMEMBRANES ARE MADE OF: - POLYOLEOFINS (HDPE, LDPE, LLDPE, TPO, VLDPE). - EPDM. - PVC LIMITATIONS OF CONVENTIONAL POLYMERIC GEOMEMBRANES: - REQUIRE WELDING AT JOINTS AND SEAMS (heat or ultrasound).

More information

Global Requirements for the Fire Protection of Ships. Dr Janet Murrell Warrington Certification Ltd

Global Requirements for the Fire Protection of Ships. Dr Janet Murrell Warrington Certification Ltd Global Requirements for the Fire Protection of Ships Dr Janet Murrell Warrington Certification Ltd Arch Timber 3 rd Castleford June 2011 International Maritime Organisation (IMO) International Maritime

More information

ISO INTERNATIONAL STANDARD. Determination of the resistance to jet fires of passive fire protection materials Part 1: General requirements

ISO INTERNATIONAL STANDARD. Determination of the resistance to jet fires of passive fire protection materials Part 1: General requirements INTERNATIONAL STANDARD ISO 22899-1 First edition 2007-12-01 Determination of the resistance to jet fires of passive fire protection materials Part 1: General requirements Détermination de la résistance

More information

A COPYRIGHT NOTICE. version 3 FLOOR COVERING STANDARD SYMBOLS ELASTISCHE, TEXTILE UND LAMINAT BODENBELÄGE INTRODUCTION.

A COPYRIGHT NOTICE. version 3 FLOOR COVERING STANDARD SYMBOLS ELASTISCHE, TEXTILE UND LAMINAT BODENBELÄGE INTRODUCTION. FLOOR COVERING STANDARD SYMBOLS INTRODUCTION The floorsymbols font can be used by pressing a key or keycombination. In this folder you can find the key or keycombination in addition to the symbol you want

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL SPECIFICATION SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION CEN/TS 1187 January 2012 ICS 13.220.50; 91.060.20 Supersedes ENV 1187:2002 English Version Test methods for external fire exposure

More information

OIL AND GAS INDUSTRY

OIL AND GAS INDUSTRY FIRED HEATER DESIGN This case study demonstrates the implementation of an API 560 fired heater compound component in Flownex. It also shows how Flownex has been used during the process design and preliminary

More information

SUPPLEMENT REPORT No.: XPL/13600/

SUPPLEMENT REPORT No.: XPL/13600/ (Pty) Ltd Certex Appointed Ex Laboratory Reg No: 1999/027771/07 Government Approved Test Laboratory (Previously AIA) T0104 7 Spanner rd, PO Box 467 Tel: +27 (11) 316 4601 Olifantsfontein Fax: +27 (11)

More information

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS 12 December 1996 Ref. T4/4.01 GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS 1 The Maritime Safety

More information

Infrared Modules for Industrial Processes. Heraeus Noblelight

Infrared Modules for Industrial Processes. Heraeus Noblelight Infrared Modules for Industrial Processes Heraeus Noblelight Carbon Twin Infrared Emitters CIR Carbon Round Tube Infrared Emitters CIR Medium Wave Infrared Emitters Fast Response, Medium Wave Infrared

More information

The Fire Resistance Performance Of Timber Or Mineral Composite Based Insulated Doorsets When Fitted With D & E Architectural Hardware Spring Hinges

The Fire Resistance Performance Of Timber Or Mineral Composite Based Insulated Doorsets When Fitted With D & E Architectural Hardware Spring Hinges Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The Fire Resistance Performance

More information

STS Directory Accreditation number: STS 0030

STS Directory Accreditation number: STS 0030 International standard: ISO/IEC 17025:2005 Swiss standard: SN EN ISO/IEC 17025:2005 BSL Baustofflabor AG Postgässli 23a 3661 Uetendorf Head: Felix Solcà Responsible for MS: Dr. Benjamin Kaeser Telephone:

More information

Infrared Modules for Industrial Processes. Heraeus Noblelight

Infrared Modules for Industrial Processes. Heraeus Noblelight Infrared Modules for Industrial Processes Heraeus Noblelight Infrared Halogen Emitters NIR Infrared Halogen Emitters NIR Short Wave Infrared Emitters Fast Response, Medium Wave Infrared Emitters Medium

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60079-1 Fourth edition 2001-02 Electrical apparatus for explosive gas atmospheres Part 1: Flameproof enclosures "d" Matériel électrique pour atmosphères explosives gazeuses Partie

More information

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES  LEADING THE WAY IN FIRE PROTECTION FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION MEANS OF ESCAPE PROTECTION CASE STUDY: SSE HYDRO GLASGOW UK

More information

IMO COMPREHENSIVE REVIEW OF THE FIRE TEST PROCEDURES CODE

IMO COMPREHENSIVE REVIEW OF THE FIRE TEST PROCEDURES CODE INTERNATIONAL MARITIME ORGANIZATION E IMO SUB-COMMITTEE ON FIRE PROTECTION 50th session Agenda item 10 FP 50/10/1 25 October 2005 Original: ENGLISH COMPREHENSIVE REVIEW OF THE FIRE TEST PROCEDURES CODE

More information

Report on First Revision June 2014 NFPA 101

Report on First Revision June 2014 NFPA 101 101 FR500 SAF-FUR (10.2.1.2 and 10.2.1.3) Recommendation: 10.2.1.2 The provisions of Section 10.2.1.1 shall not apply to mmaterials having a total thickness of less than 1/28 in (0.9 mm) that are applied

More information

First Revision No. 6-NFPA [ Section No. 2.2 ]

First Revision No. 6-NFPA [ Section No. 2.2 ] Page 1 of 18 First Revision No. 6-NFPA 555-2014 [ Section No. 2.2 ] 2.2 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471. NFPA 12, Standard on Carbon

More information

Annex to the Accreditation Certificate D-IS according to DIN EN ISO/IEC 17020:2012

Annex to the Accreditation Certificate D-IS according to DIN EN ISO/IEC 17020:2012 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-IS-13119-01-00 according to DIN EN ISO/IEC 17020:2012 Period of validity: 18.09.2017 to 07.11.2018 Holder of certificate: IMA

More information

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly INTERNATIONAL STANDARD ISO 22827-1 First edition 2005-10-15 Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Part 1: Laser assembly Essais de réception pour

More information

CAN/ULC-S109 Flame Resistance of "Argo" Fabric

CAN/ULC-S109 Flame Resistance of Argo Fabric CAN/ULC-S109 Flame Resistance of "Argo" Fabric A Report To: Design/Craft Fabric Corporation 2230 Ridge Drive Glenview, IL 60025 USA Phone: Email: (847) 904-7000 x128 mboynton@design-craft.com Submitted

More information

3th International Conference in Warsaw "MODERN TRENDS OF FIRE PROTECTION IN ROLLING STOCK"

3th International Conference in Warsaw MODERN TRENDS OF FIRE PROTECTION IN ROLLING STOCK "MODERN TRENDS OF FIRE PROTECTION IN ROLLING STOCK" FIRE PROTECTION OF FLEXIBLE METAL/RUBBER COMPONENTS INCLUDING ELEMENTS IN BOGIES PRESENTATION BY DR. DANA GREFEN page 1 Content 1. Flexible metal/rubber

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60092-350 Second edition 2001-06 Electrical installations in ships Part 350: Shipboard power cables General construction and test requirements Installations électriques à bord

More information

Reference to the Smoke Damage Index (SDI) is needed as it is part of the test method.

Reference to the Smoke Damage Index (SDI) is needed as it is part of the test method. Public Input No. 4-NFPA 287-2014 [ Section No. 1.2.3.2 ] 1.2.3.2 Indices resulting from the test methods include critical heat flux (CHF), thermal response parameter (TRP), fire propagation index (FPI),

More information

NBS Smoke Density Chamber

NBS Smoke Density Chamber NBS Smoke Density Chamber THE BENCHMARK IN FIRE TESTING NBS Smoke Density Chamber The NBS Smoke Density Chamber is widely used in all industrial sectors for the determination of smoke generated by solid

More information

New European Cable Testing and Classification

New European Cable Testing and Classification New European Cable Testing and Classification THE BENCHMARK IN FIRE TESTING New European Cable Testing and Classification Cables will be tested using 5 test methods, and classified by extending the provisions

More information

DETERMINATION OF SMOKE QUANTITIES TO BE USED FOR SMOKE DETECTION PERFORMANCE GROUND AND FLIGHT TESTS

DETERMINATION OF SMOKE QUANTITIES TO BE USED FOR SMOKE DETECTION PERFORMANCE GROUND AND FLIGHT TESTS 25 TH INTERNATIONAL CONGRESS OF THE AERONAUTICAL SCIENCES DETERMINATION OF SMOKE QUANTITIES TO BE USED FOR SMOKE DETECTION PERFORMANCE GROUND AND FLIGHT TESTS Dipl.-Ing. Kai Behle Keywords: Fire, Smoke

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60312-1 Edition 1.0 2010-09 Vacuum cleaners for household use Part 1: Dry vacuum cleaners Methods for measuring the performance INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE

More information

CAN/ULC-S109 Flame Resistance of "Xanadu" Material

CAN/ULC-S109 Flame Resistance of Xanadu Material CAN/ULC-S109 Flame Resistance of "Xanadu" Material A Report To: Design/Craft Fabric Corporation 2230 Ridge Dr. Glenview, IL 60025 USA Phone: (847) 904-7000 E-mail: mboynton@design-craft.com Attention:

More information

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information UL 2360 Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction General Information UL 2360 - Test Methods for Determining the Combustibility

More information

Fire Retardant Textile Coatings Requirements, Challenges, Solutions. ECC on fire retardant coatings 13&14/03/ Berlin

Fire Retardant Textile Coatings Requirements, Challenges, Solutions. ECC on fire retardant coatings 13&14/03/ Berlin Fire Retardant Textile Coatings Requirements, Challenges, Solutions ECC on fire retardant coatings 13&14/3/212 - Berlin Outline Centexbel: company presentation Fire retardant textile research Flame retardants

More information

Behaviour of an Intumescing System Subjected to Different Heating Conditions. Johansson, Nils; Van Hees, Patrick; Jansson, Robert; Sjöström, Johan

Behaviour of an Intumescing System Subjected to Different Heating Conditions. Johansson, Nils; Van Hees, Patrick; Jansson, Robert; Sjöström, Johan Behaviour of an Intumescing System Subjected to Different Heating Conditions Johansson, Nils; Van Hees, Patrick; Jansson, Robert; Sjöström, Johan Published in: Fire and Materials - 13th International Conferance

More information

Rules for Classification and Construction Additional Rules and Guidelines

Rules for Classification and Construction Additional Rules and Guidelines VI Rules for Classification and Construction Additional Rules and Guidelines 7 Guidelines for the Performance of Type Approvals 7 Test Requirements for Statical Converters with Semi-Conductors Edition

More information

Contact person Date Reference Page Christian Larsson P01958A 1 (3) Safety

Contact person Date Reference Page Christian Larsson P01958A 1 (3) Safety issued by an Accredited Testing Laboratory Contact person Christian Larsson 2016-09-05 6P01958A 1 (3) Safety +46 10 516 57 61 Christian.Larsson@sp.se Accred. No. 1002 Testing ISO/IEC 17025 Olar-Portconsult

More information

Criteri di Preselezione in Accordo ad UL 94 e Conformità del Prodotto Finito. Matteo Paleari Senior Project Engineer

Criteri di Preselezione in Accordo ad UL 94 e Conformità del Prodotto Finito. Matteo Paleari Senior Project Engineer Criteri di Preselezione in Accordo ad UL 94 e Conformità del Prodotto Finito Matteo Paleari Senior Project Engineer UL and the UL logo are trademarks of UL LLC 2012 Who we are Underwriters Laboratories

More information

Lloyd s Register Type Approval System Test Specification Number 3

Lloyd s Register Type Approval System Test Specification Number 3 Working together for a safer world Lloyd s Register Type Approval System Test Specification Number 3 July 2015 Performance Test Specification for Equipment to be used in Marine Applications: Electric Cables

More information

Dryflex FLAM. Halogen-Free Flame Retardant TPEs

Dryflex FLAM. Halogen-Free Flame Retardant TPEs Dryflex FLAM Halogen-Free Flame Retardant TPEs CONTENTS BRAND NAMES & NOMENCLATURE INTRODUCTION KEY PROPERTIES FLAM 600 SERIES FLAM 700 SERIES TYPICAL APPLICATIONS EXPLANATION OF FLAMMABILITY TESTS PROCESSING

More information

ISO Safety of machinery Laser processing machines Part 1: General safety requirements

ISO Safety of machinery Laser processing machines Part 1: General safety requirements INTERNATIONAL STANDARD ISO 11553-1 First edition 2005-02-01 Safety of machinery Laser processing machines Part 1: General safety requirements Sécurité des machines Machines à laser Partie 1: Prescriptions

More information

Determination of the fire resistance according to EN of vertical linear joints sealed with Henkel PATTEX FR66

Determination of the fire resistance according to EN of vertical linear joints sealed with Henkel PATTEX FR66 Efectis Nederland BV Efectis Nederland report 2011-Efectis-R1169 Determination of the fire resistance according to EN of vertical linear joints sealed with Henkel PATTEX FR66 Efectis Nederland BV Centre

More information

Vallox Oy. manufactures ventilation units Vallox TSK Multi 80 MC. over Vallox TSK Multi 80 MC

Vallox Oy. manufactures ventilation units Vallox TSK Multi 80 MC. over Vallox TSK Multi 80 MC Vallox TSK Multi 80 MC Vallox TSK Multi 80 MC Vallox Oy manufactures ventilation units Vallox TSK Multi 80 MC Certificate No VTT-C-11032-14 Translation 1 (2) Vallox TSK Multi 80 MC is intended to be used

More information