Addendum for STI-6406 with Dual Access Control

Size: px
Start display at page:

Download "Addendum for STI-6406 with Dual Access Control"

Transcription

1 Addendum for STI-6406 with Dual Access Control Description: This system contains a STI-6400 with a DPDT key switch to be mounted on one side of a door or wall; and a similar looking housing, also with a DPDT key switch, but without an alarm for the opposite side of the door. An authorized person with a key can disable the alarm on either side of the door. When disabled, and LED will illuminate, and the door can be opened without setting off the alarm. After passing through the door, the alarm can be armed again from the opposite side. Installation: 1. Follow STI-6400 mounting instructions and set switches to the desired positions for alarm timing and volume. 2. For straight through door or wall installation, mark the center of the 5/16 inch hole in the mounted base, then remove the base from the door or wall. 3. Drill a 5/16 inch diameter hole through the door or wall at the marked location. 4. Align the same diameter hole in the secondary unit base to the back side of the door or wall and mount. 5. Route the wire from the STI-6400 unit through the hole and into the secondary unit. 6. Attach the 6 wires to the terminal block pins 2 thru 7 matching wire colors on the terminal block label. 7. Seal the hole around the wires with an effective fire stop material, if required. 8. Attach the battery in the secondary unit and install the cover. 9. Cycle the key switch to be sure the LED s turn ON and OFF. Leave the LED s ON until ready to test the alarm. 10. Attach the battery to the STI-6400 and install the cover. 11. Close the door and test. Operation: 1. With the door closed, turn either key switch to arm the alarm. The LED s on both sides of the door should turn OFF. 2. If the door is opened while the LED s are OFF, then the alarm will sound according to the switch settings of the STI To reset the alarm, turn either key to the opposite position (the LED s will turn ON ), close the door and turn either key switch again (the LED s will turn OFF ). 4. When the system is armed, authorized passage can be accomplished by turning either key switch until the LED s turn ON, and remove key. The door can now be opened without sounding the alarm. When passage is complete, close the door, turn the key switch (the LED s will turn OFF ). The door alarm is once again armed. Schematic Diagram: 13 February 2017

2 Exit Stopper STI-6400 Series Features Alarm helps prevent unauthorized exits/entries through doors. Easy to install. Select volume, alarm duration and delay settings. May be mounted on top, right, left or next to almost any door. User can select on-site whether to use an alarm or annunciator. Less expensive than heavy horizontal bar type units and practical for all emergency doors. Contact STI for custom applications. We protect the things that protect you

3 Table of Contents Warnings and Cautions... Page 2 Warranty Information... Page 2 Specifications... Page 3 1. Dimensions... Page 3 2. Polycarbonate... Page 3 3. Electronics... Page 3 4. Remote Horn... Page 3 Circuit Board Set-Up... Page 4 Terminal Strip Layout... Page 4 Switch Settings... Page 4 Alarm Feature Description... Page 5 Installation Instructions All Units / STI Page 5 Mounting Options... Page 6 STI-6402 Double Door additional install notes... Page 6 STI-6403 Remote Horn additional install notes... Page 6 STI-6404 Double Door with Remote Horn additional install notes... Page 6 STI-6405 Exit Stopper with Momentary Reset... Page 6 Warnings All units are recommended for indoor use, not for outdoor use. Unit must be tested periodically to verify the life of battery. STI recommends you change the 9 Volt battery twice a year. Installer may need to purchase a simple audio-meter, typically available at your local electronics store, to measure the sound in areas where the alarm is expected to be heard during normal noise environment. Results from this test may prove it beneficial to purchase additional exit stopper units. When purchasing a remote unit (STI-6403 or STI-6404) you will need to periodically test the connections to make sure audibles function at a sound level to alert staff. Maximum of three remote alarms may be used in parallel. All specifications and information shown are current as of publication and subject to change without notice. Warranty Information Three year guarantee against breakage of polycarbonate in normal use (one year on electro mechanical and electronic components). Electronic warranty form at -

4 Specifications Polycarbonate Enclosure Dimensions W x H x 2 D (137mm x 137mm x 51mm) Flammability UL94 V-2 Wall Thickness 0.12 in (3.05mm) Electronics: STI All Units 9 VDC Alkaline or 9V-24VDC wired Power Source Class II UL Listed transformer Horn Volume at 1 ft. 95 db low / 105 db high Relay Output Form C Dry Contacts 0-30 VDC or VAC, 1 Amp Stand by Current 10uA Alarm Current 130mA at 95 db / 200mA at 105 db Operating Temperature Range 32 to 113 F (0 to 45 C) Electronics: STI-6403 and STI Remote Horn Unit Power Source 9 VDC operating power* only Horn Volume at 1 ft. 95 db low / 105 db high Stand by Current 0 A Alarm Current 50mA at 95 db/ 200 ma at 105 db * Power source for the STI-6403 and STI-6404 Remote Horn uses a separate power source from the STI-6400 alarm. The Remote Horn contains an internal 9 volt battery. Horn operates when the Form C contact at main unit is activated on alarm

5 Circuit Board Set-up ALARM VOLUME SWITCH (ON) DOOR PROP SWITCH (OFF) JP2 JP5 TERMINAL BLOCK ALARM DURATION SWITCH (OFF) (OFF) JP4 JP3 (FACTORY DEFAULT SETTINGS) JUMPER WIRE ARMING SWITCH (ON) JP7 FORM C DRY CONTACTS REMOTE POWER INPUT 9-24 VDC REED SWITCH TERMINALS KEY SWITCH TERMINALS NC COM NO GD V+ RS1 RS2 KEYSW TERMINAL BLOCK WIRING CONNECTIONS Figure 1 All models are shipped with jumper wire installed for use with one reed switch (RS2). If using second reed switch, remove jumper wire and insert second reed switch. Switch Settings FEATURE JP2 JP3 JP4 JP5 JP7 Volume - POLYCARBONATE High (105 db) BASE at 1 ft. ON* Volume - Low (95 db) at 1 ft. OFF Duration - 30 Second Alarm OFF* OFF* Duration Second 120 db HORN Alarm OFF ON Duration - Continuous Alarm ON OFF Duration - Annunciator Mode ON ON Trip - Immediate POLYCARBONATE COVER Door Prop Mode Arming - Immediate Arming - 30 Second Delay OFF* ON ON* OFF Slide black lever to desired ON/OFF position as labeled on circuit board. *Factory Settings - 4 -

6 KEYSW NC COM NO GD V+ RS1 RS2 KEYSW Alarm Feature Description Volume Switch JP2 - Sets alarm volume to high 105 db or low 95 db. Duration Switch JP3 and JP4 - Amount of time alarm sounds after trip. Arming resets at end of duration if door is closed. Alarm will not reset if in continuous mode; alarm will sound until reset with the key or until battery is drained. Annunciator mode will sound a series of short beeps until door is closed or 15 seconds. Door Prop Mode Switch JP5 - Once unit is armed with the key (OFF to ON) the alarm will sound if the door remains open for 15 seconds. If the door opens and closes within 15 seconds, the alarm will not sound. Arming Delay Switch JP7 - Delays arming of alarm for 30 seconds. To start arming delay timing, cycle the key switch (OFF to ON). Door must remain closed for 30 seconds for alarm to arm. Test Alarm Note: STI recommends testing the alarm in factory settings (see Switch Settings) prior to mounting. 1. Make sure key switch is in the OFF position. 2. Remove tamper screw on the side of the unit using the tamper wrench provided. Remove housing cover. Save the tamper wrench for future service and battery replacement (Fig. 2). 3. Connect battery. 4. Place magnet next to reed switch. Note: For STI-6402 model, insert jumper wire in RS2 terminals or install second reed switch and place magnet next to reed switches 1 & Turn the key switch to the ON position. 6. Move magnet away from reed switch. Unit should alarm immediately. 7. Turn unit off with the key to silence alarm. Installation Instructions 1. Set switches on circuit board to desired alarm settings (Fig. 1). 2. If using external power source, use Class II UL Listed transformer. 9V battery will be in no-load standby. 3. Mount main unit on or next to the door using hardware provided. Reed switch may be moved to one of four positions shown in Fig. 2 or you may route the reed switch through the knockout in the bottom of the cover as shown in Fig Mount magnet using hardware provided. Magnet must be within ¾ of the reed switch when door is closed. Please refer to figures 7, 8 and 9 for other mounting options. Note: When mounting on metal doors or door frame, use plastic spacers provided. Magnet must be within 3/8 of the reed switch when door is closed. 5. If installing STI-6402, STI-6403, STI or STI-6405 continue to page Replace cover by sliding flanges on inside of cover into slots on base, snap closed and replace the tamper screw. SCREW 6 x 1 1/4 in EMERGENCY USE ONLY ALARM SOUNDS WHEN DOOR IS OPENED ON OFF COVER REED SWITCH MOUNTING LOCATIONS (LABELED 1-4) NC COM NO GD V+ RS1 RS2 KEYSW FLANGES VIEW SHOWING MAGNET INSTALLATION MAGNET COVER 4 MOUNTING SCREW (4) PROVIDED SLOTS 1 TERMINAL STRIP 9 VOLT BATTERY 2 TAMPERPROOF SCREW (1) PROVIDED 3 TAMPER WRENCH BASE (1) PROVIDED FLANGES REMOVE FRONT COVER AND ROUTE REED SWITCH WIRES THROUGH NOTCH ON BOTTOM SURFACE AS SHOWN MAXIMUM GAP 3/4 in. (19mm) 3/8 in. (9.5mm) ON METAL DOOR AND FRAME REED SWITCH MOUNTING LOCATIONS SPACERS (USE AS NECESSARY) NOTE: 2 SPACERS UNDER BOTH 4 MAGNET AND REED SWITCH MUST BE USED ON STEEL DOORS ANCHOR Figure 2 Figure 3

7 STI-6402 Double Door Install Notes 1. If not using extra reed switch, leave jumper wire across terminals RS2 on terminal block. 2. Determine length needed for reed switch wires. STI provides 1 reed switch with 6 ft. wires. Cut to desired length. 3. Connect first reed switch in RS1 and second in RS2 (Fig. 5). (Refer to Fig. 1 for additional details.) *Note: Alarm will sound when either door is opened. TERMINAL BLOCK OPTIONAL: TO REMOTE HORN STI-6403 INTERNAL REED SWITCH (RS1) TO KEY SWITCH VIEW SHOWING INSTALLATION OF ADDTIONAL REED SWITCH KIT-E06402 KIT-E06402 REED SWITCH (RS2) Figure 4 STI-6403 Remote Horn Install Notes 1. Remove cover. 2. Connect two conductor wire (14-24 AWG) from main unit terminal block pins COM and NO to remote horn unit terminal block. (wire not provided). Units can be set up to 300 ft. apart. Not polarity sensitive (refer to Fig. 1 and Fig. 5 for details). 3. Connect internal battery. 4. Mount similar to main unit with #8 x 1 in. screws and anchors if necessary. 5. Replace cover and screws. 6. Turn key switch to ON position. *Note: The ON/OFF key position is opposite from 6400 main unit. Remote horn sounds when main unit alarm is activated. ROUTE WIRES THROUGH NOTCH KEY SWITCH STI-6403 REMOTE HORN UNIT INSTALLATION Figure 5 STI-6404 Double Door with Remote Horn Install Notes The STI-6404 is a combination unit for double doors with a remote horn. Reference the installation instructions for the main unit, the STI-6402 and the STI-6403 for complete installation. STI-6405 Exit Stopper with Momentary Reset The STI-6405 uses a momentary switch. After initial installation, unit is always on and you do not have to remember to turn it on when you leave a protected area. This model also eliminates having to remember to re-arm it because it is never off. When the alarm is triggered, to silence the alarm, insert the key and turn completely to the RESET position and hold for 2 seconds, then release. The switch will spring back to its original position and push the key out. To turn the unit off, supply power must be removed RESET Figure 6

8 INSTALLATION SCREW Mounting 6 Options x 1 1/4 in. SCREW 6 x 1 1/4 in. MAGNET MUST BE INSTALLED OPPOSITE RAISED RIB ON OUTER COVER SPACERS - USE NOTE: (2) SPACERS MUST BE AS NECESSARY USED ON STEEL DOORS TYPICAL FLUSH MOUNT DOOR JAMB INSTALLATION ANCHOR MAGNET MAGNET MUST BE INSTALLED OPPOSITE 6400 UNIT RAISED RIB ON OUTER COVER SPACERS - USE NOTE: (2) SPACERS MUST BE AS NECESSARY USED ON STEEL DOORS DOOR ANCHOR MAGNET SWING 6400 UNIT DOOR SWING JAMB DOOR STOP DOOR JAMB DOOR STOP DOOR Figure 7 TYPICAL RECESSED MOUNT DOOR JAMB INSTALLATION MAGNET ASSEMBLY (SEE ABOVE FOR INSTALLATION) TYPICAL RECESSED MOUNT DOOR JAMB INSTALLATION DOOR STOP MAGNET MAGNET ASSEMBLY (SEE ABOVE FOR INSTALLATION) 6400 SWING DOOR STOP 3/4 in. (19mm) MAXIMUM GAP 3/8 in. (9.5mm) ON METAL DOOR AND FRAME 3/4 in. (19mm) MAXIMUM GAP 3/8 in. (9.5mm) ON METAL DOOR AND FRAME DOOR SWING MAGNET 6400 SWING *Note: When mounting reed switch on door and the main unit on wall, wire DOOR service loop must be used. SWING Figure 8 TYPICAL DOUBLE DOOR INSTALLATION STI-6402 INTERNAL REED SWITCH (RS1) - 7 -TO KEY SWITCH Figure 9

9 2306 Airport Rd Waterford, MI 48327, USA Phone: Fax: Safety Technology International Ltd Taylor House 34 Sherwood Road Bromsgrove Worcestershire B60 3DR England Tel: +44 (0) Fax: +44 (0) Printed in USA Subject to change without notice Inst SEPT2014

Exit Stopper. STI-6400 Series

Exit Stopper. STI-6400 Series Exit Stopper STI-6400 Series Features Alarm helps prevent unauthorized exits/entries through doors. Easy to install. Select volume, alarm duration and delay settings. May be mounted on top, right, left

More information

Exit Stopper. STI-6400 Series

Exit Stopper. STI-6400 Series Exit Stopper STI-6400 Series Features Alarm helps prevent unauthorized exits/entries through doors. Easy to install. Select volume, duration and immediate or 15 second delay for arming and trip. May be

More information

Protective Cabinet STI-7534, STI-7535 and STI-7535AED

Protective Cabinet STI-7534, STI-7535 and STI-7535AED Protective Cabinet STI-7534, STI-7535 and STI-7535AED Features Clear, protective polycarbonate cover with siren/strobe alarm. Design allows visibility at any angle. Complete with mounting hardware and

More information

EPO STATION. EPO Station with push to activate, turn to reset button complete with a clear cover to help

EPO STATION. EPO Station with push to activate, turn to reset button complete with a clear cover to help EPO STATION EPO Station with push to activate, turn to reset button complete with a clear cover to help prevent accidental activation and a bold "EMERGENCY POWER OFF" label. Color: White Shell Phrase:

More information

STI-1229-HAZ STI-1229HTR-HAZ STI-1229HTR240-HAZ

STI-1229-HAZ STI-1229HTR-HAZ STI-1229HTR240-HAZ STI-1229-HAZ STI-1229HTR-HAZ STI-1229HTR240-HAZ Enclosure Only Enclosure with 110 VAC Heater Option Enclosure with 240 VAC Heater Option Features Hazardous Classification Class II Groups F&G Div. 2 and

More information

Illuminated Stopper Station Push Button

Illuminated Stopper Station Push Button Illuminated Stopper Station Push Button Model SS2xx6 Rely on STI Dimensions 4.880 in [123.95 mm] 3.218 in [81.74 mm] 1.625 in [41.28 mm].875 in [22.23 mm] Switch Rating 2 momentary independent Form C contacts,

More information

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING EMBOSSED PROGRAMMING SWITCHES 1-8 ANTENNAS ZONES: LEFT BUTTON CALL Embossed Programming Instructions: Installation and Operation Manual STI 8-Channel 1 - MIRROR MASTER OFF/ON RIGHT BUTTON FRONT COVER RESTORE

More information

Installation and ZONES: Operation Manual. Model: ON STI-34108

Installation and ZONES: Operation Manual. Model: ON STI-34108 N.O. COM N.C. + 12 V - IN + 12 V - OUT 500 ma 300 ma PLUG IN ADAPTER 12 V 500mA Trigger Output 12 V 75mA N.O. COM N.C. + 12 V - IN + 12 V - OUT 500 ma 300 ma PLUG IN ADAPTER 12 V 500mA Trigger Output 12

More information

STANDARD FEATURES SPECIFICATIONS

STANDARD FEATURES SPECIFICATIONS MAG LOCK P/N 300768 STANDARD FEATURES Holding Force: 1500 lbs.(675 Kg.) Easy Installation: Versatile mounting bracket for new and existing doors and frames. Sensor: Built-in Hall effect crystal affected

More information

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions 1 PACKAGE CONTENTS Wiring Harness 6 Wire Nuts #6 x 3/4 Screws s BP7175 3/16 Wall Plugs Section 1: General Description Camden CM-RQE-70 Request-to-Exit

More information

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

CM-RQE70 PIR REQUEST TO EXIT DETECTOR Door Activation Devices CM-RQE70 PIR REQUEST TO EXIT DETECTOR THIS PACKAGE INCLUDES (1) Wiring Harness (2) #6 x 3/4" Screws (2) 3/16" Wall Plugs (6) Wire Nuts (2) 's BP7175 1. GENERAL DESCRIPTION Camden

More information

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

CM-RQE70A PIR REQUEST TO EXIT DETECTOR Door Activation Devices CM-RQE70A PIR REQUEST TO EXIT DETECTOR THIS PACKAGE INCLUDES (2) #6 x 3/4" Screws (2) 3/16" Wall Plugs (2) MOV's BP7175 1. GENERAL DESCRIPTION Camden CM-RQE70A Request-to-Exit Sensor

More information

SP-4004 OPTICAL-ACOUSTIC OUTDOOR SIREN sp4004_en 03/13

SP-4004 OPTICAL-ACOUSTIC OUTDOOR SIREN sp4004_en 03/13 SP-4004 OPTICAL-ACOUSTIC OUTDOOR SIREN sp4004_en 03/13 The SP-4004 siren provides information about alarm situations by means of optical and acoustic signaling. The device is designed for outdoor installation.

More information

Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9 Installation and Service Instructions Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9 ADA Compliant NOTE For LTUL Models, Form C contacts on timer, Rated 30 VDC 3A, the enclosed timer

More information

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button Stopper Station Series SS-2008 Push Button Pneumatic Timer Button ADA for operation Pneumatic Timer Models SS-2008 Red SS-2108 Green SS-2208 Yellow SS-2308 White SS-2408 Blue ALL MODELS COME WITH A COLOR

More information

Stopper II Heated Enclosure

Stopper II Heated Enclosure Stopper II Heated Enclosure STI-1200A-HTR STI-1200A-HTR240 ADA Compliant Maintains initiating device temperature with external temperatures to -70 F (-57 C). Independently tested to -102 F (-73 C). Protects

More information

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev Installation Guide for AL600ULM Multi-Output Access Control Power Supply Charger Rev. 091800 1 AL600ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL600ULM multi-output access control

More information

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL Crypto-Lock Model CC-8521B Updated 7/17 Access Control System INSTRUCTION MANUAL MONITEQ, Inc. 2 TABLE OF CONTENTS 1. INTRODUCTION..4 2. SPECIFICATIONS.....6 3. SUPPLIED EQUIPMENT.. 6 4. FUNCTIONS OF CONTROLS

More information

Installation Instructions

Installation Instructions Request-to-Exit Dual Technology Motion Sensor 1048889B November 2005 Copyright 2005, GE Security Inc. Introduction This is the GE Request-to-Exit Dual Technology Motion Sensor for models -W, -B, and -G.

More information

Child Resistant Pool Alarms

Child Resistant Pool Alarms Home Products About GRI Contact GRI Where to Buy Testimonials What's New! Child Resistant Pool Alarms Recessed Shunt Button with Protective Guard Ring Microprocessor Controlled Monitors Entry To Pool and

More information

Installation Guide for models:

Installation Guide for models: 140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal3FD - 12VDC @ 4.6 amp or 24VDC @ 5.2 amp. - Sixteen (16) PTC protected power-limited outputs.

More information

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS OPERATES ON 12 OR 24 VOLTS AC/DC, AUTO VOLTAGE SENSING FULLY PROGRAMMABLE FROM THE KEYPAD

More information

Pilfergard Door Alarms

Pilfergard Door Alarms Alarm Lock PilFergard Door Alarms Pilfergard Door Alarms A PG10 Pilfergard model PG10 exit door alarm designed to deter the use of the secured door by sounding a twin action alarm when opened by unauthorized

More information

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide Introduction This is the Interlogix RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Instructions for models RCR-REX-W,

More information

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger Installation Guide for AL300ULM Multi-Output Access Control Power Supply Charger R AL300ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL300ULM multi-output access control power supply/charger

More information

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F II 1400-2 ACSI 1406-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F INSTALLATION Transformer Model BE31763001 by Basler Electric, Transformer Model 2010028 by Galaxy

More information

ANNUNCIATOR FIXED MODULE

ANNUNCIATOR FIXED MODULE 12 Clintonville Road Northford, CT 06472 Phone: 203-484-7161 Fax: 203-484-7118 THE ANNUNCIATOR FIXED MODULE Installation Manual for the AFM-16ATF and AFM-32AF Annunciator Modules Document # 15970 3/27/95

More information

AED Alarm System Model Operations Manual

AED Alarm System Model Operations Manual AED Alarm System Model 200900 Operations Manual Printed In the USA 2005 Table of Content Section 1 o Features Alarm volume Alarm settings Mechanical door switch External alarm connection Low battery chirp

More information

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations: F1! 44487023 These instructions cover the following parts: PS902 Power Supply Installation Instructions! DANGER: To avoid risk of electric shock, turn off AC power before installing or servicing PS902

More information

MODEL B2 INSTALLATION MANUAL

MODEL B2 INSTALLATION MANUAL RELEASE DEVICES GENERAL DESCRIPTION MODEL B2 INSTALLATION MANUAL S/N: The B2 Series Time Delay Release Devices are UL Listed, Canadian Listed, and CSFM Listed for use on rolling doors, single-slide and

More information

Gate Mount Pool Alarms

Gate Mount Pool Alarms Home Products About GRI Contact GRI Where to Buy Testimonials What's New! Gate Mount Pool Alarms GT10-2/GT10-4 Microprocessor Controlled Monitors Entry to Pool and Spa Areas Weather Resistant for Outdoor

More information

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL MADE IN THE U.S.A. U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION SERIAL NUMBER The Cookson Company FIREFLY II PLUS Time Delay Release

More information

Installation Guide for models:

Installation Guide for models: 140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal11F - Power Supply 1: 12VDC @ 3.3 amp or 24VDC @ 3.6 amp. - Power Supply 2: 12VDC @ 3.3 amp

More information

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products: Model 2102 Gas Alarm Panel APPLICABILITY & EFFECTIVITY This manual provides instructions for the following Sierra Monitor products: Model Description 2102-00 Alarm Panel 2 Channel 2102-01 Alarm Panel 2

More information

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit Emergency Light Unit IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. Do not

More information

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs ACM Series Access Power Controllers with Power Supplies Installation Guide Models Include: AL400ULACM AL600ULACM - 12VDC @ 4 amp - 12VDC or 24VDC @ 6 amp. or 24VDC @ 3 amp - Fused Outputs - Fused Outputs

More information

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

La Marche Manufacturing Company   Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual La Marche Manufacturing Company www.lamarchemfg.com Option 16 Series Digital Combined Accessory Package Installation and Operation Manual This manual is subject to change without notice. You may obtain

More information

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE Fire Door Release MODEL AR-D MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

Series. Access Power Controllers. Installation Guide

Series. Access Power Controllers. Installation Guide Series Access Power Controllers Installation Guide Models Include: Maxim11 - Power Supply 1: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Power Supply 2: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Sixteen (16) fuse

More information

SPECIFICATIONS. Contents List

SPECIFICATIONS. Contents List INSTALLATION INSTRUCTIONS FOR PB-SA PUSH BUTTON SYSTEM ABORT The information contained in this installation instruction is a quick reference guide. For detailed system information refer to the panel manufacturers

More information

Wireless D.I.Y. Alarm Kit

Wireless D.I.Y. Alarm Kit Wireless D.I.Y. Alarm Kit User Manual December 2010 MAMI 21 Hubert Mathew Road Illiondale 1610 Tel: +27 11 452 4737 Email: sales@mami.co.za page 2/10 General The Wireless DIY kit, is a pre-programmed,

More information

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES POWER SUPPLY AND BATTERY CHARGER AC AND DC STATUS INDICATORS ENOUGH POWER TO SUPPORT UP TO 3 MAGLOCKS OR ELECTRIC STRIKES PLUS REQUIRED

More information

Stopper II SERIES ADA. We protect the things that protect you

Stopper II SERIES ADA. We protect the things that protect you Stopper II SERIES ADA Compliant See Testing Approvals Can be used as a guard against physical damage to manual pull station, with or without optional warning horn. Optional horn has choice of 95 db or

More information

Independent Zone Control (I.Z.C.)

Independent Zone Control (I.Z.C.) Operation and Installation Guide Independent Zone Control (I.Z.C.) DELAYED INSTANT ARMED 1 2 3 4 7 5 6 8 9 * * fi Radionics R D279A Operation & Installation Guide 46456B Page 2 Copyright 2000 Radionics

More information

WM3000 WIRELESS MODULES

WM3000 WIRELESS MODULES WM3000 WIRELESS MODULES $$:05 $$:07 INSTALLATION INSTRUCTIONS Table of Contents Installation... 3 Mounting Instructions & Connections... 3 Setting the Dip Switches... 4 Setting the Recognition Time...

More information

NetworX NX-548E Receiver Installation Instructions

NetworX NX-548E Receiver Installation Instructions NetworX NX-548E Receiver Installation Instructions Content Introduction... 1 Internal mounting... 1 External mounting... 2 Wiring... 3 DIP switch settings... 3 Power up... 3 Programming... 4 Testing and

More information

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-3 ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS Features: For use with doors or groups of doors that must interlock with each other to regulate control of accessing one area from another,

More information

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE Fire Door Release MODEL AR-D2 MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D2 GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation PS6 SERIES Power Supplies PS6 SERIES Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation and Specifications Manual ISDPS6_SERIES 08121590 PCN15016 R05/15GR

More information

EVO192 v3.0 Fire and Burglary What s New

EVO192 v3.0 Fire and Burglary What s New EVO192 v3.0 Fire and Burglary What s New Compatibility: EVO192 v3.0 TM50 v1.31 K641 v2.41 Overview: CP-01 Compliancy Wiring Diagram The following sections/options have been added to the EVO192 panel. They

More information

User Manual X8s Access Control System

User Manual X8s Access Control System User Manual X8s Access Control System Version: 1.0 I 1. Equipment Installation (1) Remove the screw from the bottom of the device. (2) Remove the back cover of the device. (3) Fix the back cover on the

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 031703 Overview: The Altronix AL802ULADA is an extremely cost effective 8 amp voltage regulated

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger Installation Guide for AL400ULM Multi-Output Access Control Power Supply Charger R AL400ULM - Multi-Output Access Control Power Supply/Charger Rev. 072500 Overview: The AL400ULM multi-output access control

More information

CM800 Emergency Call System

CM800 Emergency Call System Submittal Package as of 5/25/2017 Phone: 828.524.9967 Toll-Free: 800.327.8466 Sales: Option 2 Tech Support: Option 3 324 Industrial Park Road Franklin, NC 28734 tektone@tektone.net Fax: 828.524.9968 Copyright

More information

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel DS3MX-E-I EN Installation Guide 3 Mini Control Panel DS3MX-E-I Installation Guide 1.0 General Information EN 2 1.0 General Information The DS3MX is a three zone mini control panel, which can be installed

More information

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

THE SS90 SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL S S S S S S S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED U 99Y9 RESET L RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

INSTALLATION INSTRUCTIONS 101-DE/101-KDE

INSTALLATION INSTRUCTIONS 101-DE/101-KDE 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com Verbal Exit Instructions or Alarm Tone Only and Digital Countdown Display Application: INSTALLATION

More information

DS160/DS161 Request To Exit PIR sensors Installation Instructions

DS160/DS161 Request To Exit PIR sensors Installation Instructions DS160/DS161 Request To Exit PIR sensors Installation Instructions 1.0 Description The DS160 is a Passive Infrared Detector (PIR) which is UL Listed as an Access Control Device under the UL 294 Standard.

More information

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE D (OPERATION) INITIATE A DYNAMIC BATTERY TEST The system tests the back-up battery once every 24 hours. The owner can initiate a dynamic battery test at any time with the following codes while the system

More information

Conventional Releasing Control Panel

Conventional Releasing Control Panel s Data Sheet Fire Safety Products Conventional Releasing Control Panel Pre-Action Deluge Agent-Releasing Fire System Model TXR-320 Remote configurable Up to two (2) hazard areas Operable with the following:

More information

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation The most user friendly Contents Section 1 Overview of System 1.1 Kit Contents 1.2 Tools Required 1.3 System Features Security Alarm System L S 4 0 0 Section 2 Planning your Installation 2.1 Location of

More information

TRX MAINS CONNECTION DIAGRAM

TRX MAINS CONNECTION DIAGRAM TRX MAINS CONNECTION DIAGRAM Switch 230VAC 10A Neutral Out Phase Out TRX MAINS Phase In Neutral In LOAD 8A MAX. Specifications: Operating Voltage: 220-240VAC 50Hz Current Draw: 5mA Max. Switching Current:

More information

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC. M Series Multi-Output Access Control Power Supply Charger Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 4 amp @ 12VDC or 3 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp @

More information

CORNELL Emergency Response Systems

CORNELL Emergency Response Systems CORNELL Emergency Response Systems Door Monitor Systems Series 1000 CORNELL Communications, Inc. Milwaukee, WI USA 800-558-8957 - www.cornell.com rev 6/04 A-1000 SERIES DOOR MONITOR OPERATION AND WIRING

More information

Alarmed Exit Hardware

Alarmed Exit Hardware Copyright 2005, 2007, 2009-2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Contents 540/550 Series Exit Alarm...1 5100 Series Alarmed Exit Lock...2 5800 & 12-5800

More information

ELECTRONIC SOUNDER STROBE Model : AVD-C407

ELECTRONIC SOUNDER STROBE Model : AVD-C407 ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an

More information

INSTALLATION MANUAL SOUNDER MODELS RIALTO L LS X LSX TRIADE L LS QL QLS LIDO L X LS LSX

INSTALLATION MANUAL SOUNDER MODELS RIALTO L LS X LSX TRIADE L LS QL QLS LIDO L X LS LSX INSTALLATION MANUAL SOUNDER MODELS RIALTO L LS X LSX TRIADE L LS QL QLS LIDO L X LS LSX DESCRIPTION L models description: self-powered 12 Vdc sounder with high-brightness low-consumption LED flashing unit

More information

AL600ULADA. NAC Power Extender. Installation Guide

AL600ULADA. NAC Power Extender. Installation Guide AL600ULADA NAC Power Extender Installation Guide Rev. 122000 AL600ULADA - NAC Power Extender Overview: The Altronix AL600ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery

More information

Remote Display Alarm Indicator for Oxygen monitor

Remote Display Alarm Indicator for Oxygen monitor Remote Display Alarm Indicator for Oxygen monitor (Part number 99091) The Remote Display Alarm Indicator is designed to display remote oxygen concentration information from PureAire oxygen monitors. All

More information

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION: RELEASE DEVICES MADE IN THE U.S.A. RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION: S/N: The "WPS" World Power Series, Time Delay Release

More information

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC. M Series Multi-Output Access Control Power Supply Chargers Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 3 amp @ 12VDC or 4 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp

More information

Public Safety DAS Annunciator Panel

Public Safety DAS Annunciator Panel Public Safety DAS Annunciator Panel 120 VAC Models: 1221-A, 1221-B, 1221-C Revision D 91117 48 VDC Models: 1221-A-48, 1221-B-48, 1221-C-48 24 VDC Models: 1221A-24, 1221-B-24, 1221-C-24 CAUTION: (Read This

More information

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions HZM-Series-Class I, Div 2 Battery Unit HZM-Series-Class I, Div 2 Battery Unit Instalation instructions IMPORTANT SAFEGUARDS 1 4 5 6 7 13 When using electrical equipment, basic safety precautions should

More information

The TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel

The TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel 12 Clintonville Road Northford, CT. 06472 (203) 484-7161 FAX:(203) 484-7118 The TC-4F Time Control Module For the Sensican 2000 Fire Alarm Control Panel Document # 15972 3/27/95 Revision C P/N 15972:C

More information

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR ED820 24V MODEL fire DETECTOR INSTRUCTION MANUAL Address: Enigma House, Enigma Business Park, Malvern, Worcestershire, WR14 1GD Tel: 44 (0)1684 891500 Fax: 44 (0)1684 891600 Email: sales@electronicdevices.co.uk

More information

Installation Instructions

Installation Instructions Fixture Mount Night Light Controller SPECIFICATIONS Power.....................................120VAC, 60Hz Relay Type..................................Form C, N.O. Load Requirements @120VAC......................................500W..........................

More information

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL Firefly II Multi Voltage RELEASE DEVICES Firefly II & IIB-MV INSTALLATION MANUAL GENERAL DESCRIPTION: S/N The The Cookson Company Firefly II-MV time delay release devices are designed for use on rolling

More information

Shed Alarm Kit. User Manual

Shed Alarm Kit. User Manual Shed Alarm Kit User Manual INTRODUCTION The Shed Alarm Kit is an intruder alarm and chime integrated system, designed to protect your shed. It is a simple to use, easy to install unit. Whats included in

More information

VSR-M REPLACEMENT Waterflow Switch for Globe Sprinkler Model UMC Manifold

VSR-M REPLACEMENT Waterflow Switch for Globe Sprinkler Model UMC Manifold Features NEMA 4 solid metal enclosure Factory installed neoprene gasket 0-90 second field replaceable pneumatic retard 350 PSI system pressure rated Synchronized switch action Waterflow switches that are

More information

AL800ULADA. NAC Power Extender. Installation Guide

AL800ULADA. NAC Power Extender. Installation Guide AL800ULADA NAC Power Extender Installation Guide Rev. 122000 AL800ULADA - NAC Power Extender Overview: The Altronix AL800ULADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery

More information

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual ITC 2000 HEATING CONTROL CABINET Installation & Operation Manual VTI, Incorporated 24 McMillan Way Newark, DE 19713 Phone (302) 738 0500 FAX (302) 738 6594 Revision Level 0.03 Manual No. 90003314 June,

More information

DE5300 Delayed Egress System. General Information

DE5300 Delayed Egress System. General Information *911031-00* 911031-00 Wiring and Configuration DE5300 Delayed Egress System Installation Instructions General Information The Von Duprin DE5300 is designed for controlled egress applications when used

More information

4100U City and Relay Cards Installation Instructions

4100U City and Relay Cards Installation Instructions 4100U City and Relay Cards Installation Instructions Introduction This publication describes the installation procedure for the following: 4100-6031/6032 City Circuit Cards 4100-6033 Alarm Relay Card Inspecting

More information

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel CVENTIAL ALARM S Features: Description: The LF-CP Series Fire Alarm Control Panel is manufactured based on advanced technology while maintaining high quality during assembly. It is of solid state circuitry

More information

ALARMED EXIT HARDWARE

ALARMED EXIT HARDWARE ALARMED EXIT HARDWARE Table of Contents 540/550 Series Exit Alarms.............................................1 5100 Series Alarmed Exit Lock..........................................2 5800 & 12-5800

More information

General Purpose IO Technical Manual

General Purpose IO Technical Manual General Purpose IO Technical Manual Revision 1.06 8 November 2013 Pakton Technologies PAE222 GPIO Manual.docx Page 1 of 21 Revision 1.06 Last updated 8/11/2013 Table of Contents INTRODUCTION...3 Scope

More information

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...

More information

Pump-Up Controller MODEL 4062

Pump-Up Controller MODEL 4062 Pump-Up Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4062 Pump-Up

More information

DS160/161 Request To Exit PIR sensors Installation Instructions

DS160/161 Request To Exit PIR sensors Installation Instructions DS160/161 Request To Exit PIR sensors Installation Instructions 1.0 Description The DS160/161 is a passive-infrared (PIR) detector designed for request to exit (REX) interior applications. It is UL Listed

More information

Delayed Egress System DORMA EMDE

Delayed Egress System DORMA EMDE Delayed Egress System DORMA EMDE Delayed Egress System EMDE-1000 Series Delayed Egress Systems Designed to meet NFPA Life Safety Code 101, Special Locking Arrangements, these U.L. listed, self-contained

More information

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps TT-1023 1/97 INSTALLATION INSTRUCTIONS Original Issue Date: 2/94 Model: 6-2000 kw Market: Industrial Subject: Flush- or Surface-Mount Remote Annunciator Kits PA-293991 and PA-293991-SD The remote annunciator

More information

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV LC1 & 2 Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV ZIRCONLC1 One Zone Conventional Fire Panel ZIRCONLC2 Two Zone Conventional Fire Panel Compliant with EN54-2:1998 & EN54-4:1998

More information

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual Revision 1.03 8 November 2013 JVA Technologies Ethernet General Purpose IO Technical Manual www.jva-fence.com.au Table of Contents INTRODUCTION...3 Scope and Purpose...3 Glossary...3 SPECIFICATIONS...4

More information

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE Cookson 100 Elmwood Avenue Crestwood Industrial Park Mountaintop, PA 18707 Phone: 800-233-8366 Fax: 800-526-0841 CornellCookson.com O W N E R S M A N U A L M O D E L S F I R E G A R D M C F I R E G A R

More information

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions 3LERHZ Series Class I, Div 2 Combo Unit Installation instructions 3LERHZ Series Class I, Div 2 Combo Unit IMPORTANT SAFEGUARDS 1 3 When using electrical equipment, basic safety precautions should always

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

1. POWERPATH Operation

1. POWERPATH Operation 273 Branchport Avenue Long Branch, NJ 07740 (800) 631-2148 www.wheelockinc.com Thank you for using our products. INSTALLATION INSTRUCTIONS MODEL PS-12/24-6 POWERPATH Use this product according to this

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)

More information

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual Contents I. SPECIAL FEATURES 1 II. FRONT PANEL 1 III. INSTALLATION PROCEDURES AND PROXIMITY CARD TYPES 2 IV. SETTING

More information