1 HIGH RANGE DIGITAL DEW POINT METER & MONITOR Model #8074 IMS # (TED1-8074) 2004 IMS Co. October, 2004 IMS Company Stafford Road Chagrin Falls, OH Telephone: (440) Fax: (440) Website: imscompany.com

2 TABLE OF CONTENTS Safety Summary... 2 Product Description... 3 Product Specifications... 4 Operation... 5 Installation... 6 Choosing A Sampling Location... 6 Normal Sampling... 6 Positive Pressure Sampling... 6 Test Results... 7 Maintenance... 8 Sensor Replacement Procedure... 8 Alarm Set Point Adjustment... 8 Recorder Output Selection... 9 Display Units Selection... 9 Electronic Test Procedure... 9 Replacement Parts ILLUSTRATIONS Parts Identification Assembly Drawing Mounting and Wiring Diagram Airflow Schematic October, 2004 Page 1 of 16

3 SAFETY SUMMARY This manual uses the following signal words to call attention to the safety sign and to designate a degree or level of hazard seriousness. 1. DANGER: indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. This signal word is limited to the most extreme situations. 2. WARNING: indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. 3. CAUTION: indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Also used to alert against unsafe practices or property damage only accidents. 4. NOTE: indicates general safe practices, machine use instructions and information, property damage only hazards, temporary hazards, precautions to avoid a hazard, results of not avoiding a hazard, or any combination of these messages. 5. SYMBOL/PICTORIAL: conveys a message without words. 6. SAFETY ALERT SYMBOL: indicates a potential personal injury hazard; an exclamation point inside a triangle. October, 2004 Page 2 of 16

4 PRODUCT DESCRIPTION The IMS Company Model 8074 Dew Point Meter and Monitor is used in the Plastics Industry to check for moisture in the output air from a hot air dryer, mechanical refrigeration-type dryer, or from the ambient air. The reading is useful as a reference point for the drying and molding process and is given as Dew Point Temperature. The dryer the air, the lower the dew point. You can monitor the performance of your drying equipment by measuring the dew point of drying air. A green light indicates dew points of drying air at or below the set point while a red light and audible alarm indicate dew points above the set point. Dew point temperature is digitally displayed. A cooling coil cools sampled air to a measurable temperature and the unit has a bleed valve for high pressure testing. A chart recorder outlet has a 4 to 20 ma DC linear signal that can be used by a chart recorder to track levels of dryness. The output can easily be changed to 0 to 5 Volts (refer to instructions on Page 8). The unit is self-contained and portable. Model 8074 Dew Point Meter and Monitor is factory calibrated with a NIST traceable certificate. The meter s sampling pump draws an air sample and pumps it into a chamber that contains a moisture sensor called a hygrosensor. The amount of moisture in the sample affects the sensor s electrical resistance. Interpreting that resistance, the meter shows dew point temperature on the LED display. NOTE Although the Model 8074 reads dew points from +10 to +70 F, the chart recorder output is on a -40 to +70 F scale. IMS Chart Recorder # is scaled from -40 to +70 F. If you use another chart recorder, you might want to set it to 50% of scale. DEW POINT TEMPERATURE --- A LAYMAN S EXPLANATION Warm air can hold a lot of moisture. As air temperature drops, so does its ability to hold moisture. At some point the air becomes saturated and dew forms. That point is called the dew point temperature of that air sample. Rather than actually chilling a sample to the point of saturation, the IMS Company Model 8074 Dew Point Meter and Monitor measures the moisture content and calculates the dew point temperature. For example, if this meter reads +40 F, it means that the actual air temperature would have to drop to +40 F before the moisture in the sample would form dew. October, 2004 Page 3 of 16

5 SPECIFICATIONS Dew Point Range F to +70 F (-12 C to +21 C)...at +73 F sample air temperature...0 F to +50 F (-18 C to +10 C)...at +50 F sample air temperature F to +90 F (+2 C to +32 C)...at +100 F sample air temperature Ambient Air Temperature...50 F to +100 F (10 C to 38 C)...sample air temperature is approximately...equal to ambient air temperature Accuracy...+2 F (1 C) Pressure Range...-1 to +7 psig Alarm Indication...Red Light and Audible Alarm With Silencer Switch Alarm Set Point F (10 C) Adjustable Recorder Output...2-pin connector ma Scaled as -40 F to +70 F...Jumper Selectable 0 to 5 Volt Sensor Part No Dimensions Carrying Case 9 X 12-1/2 X 5 Deep Net Weight...8 lbs. Power Requirements...115VAC +10% 50/60Hz 0.1 AMPS...(230V available) Pump Specifications...Flow: 2.5L/min. (0.08 SCFM)...Vacuum: 6 Hg...Pressure: 3.2 psi...(all pump specifications are nominal) October, 2004 Page 4 of 16

6 OPERATION PRINCIPLE OF OPERATION The Model 8074 Dew Point Meter and Monitor has a vacuum pump that pulls sample air into a sensor manifold. The sensor manifold contains a 3-element moisture sensor and a temperature transducer. With humidity and temperature signals, the circuitry can provide temperature compensated dew point measurement. The Dew Point Meter and Monitor is normally used to sample air that is at a pressure between 1 and +7 psig. Higher pressures can be tolerated by opening the selector valve on the side of the unit (refer to the POSITIVE PRESSURE SAMPLING Section on Page 6). Air up to 500 F (dry bulb) can be sampled if appropriate tubing is used. The plastic Tygon tubing supplied can withstand temperatures up to 180 F. October, 2004 Page 5 of 16

7 INSTALLATION Refer to Page 11 for Parts Identification. NOTE A key for the meter case and the unit s serial number tag are behind the foam padding in the case lid when the unit is shipped. CHOOSING A SAMPLING LOCATION The best sampling location is usually the main distribution line of the air system. Follow these guidelines when selecting a sampling location: 1. Sample air should be free of oil, particulates, and condensation. 2. Be aware of ambient and sample air temperature limitations listed in the SPECIFICATIONS Section on Page 4. NORMAL SAMPLING Normal sampling implies that the sampled air pressure is between -1 and +7 psig. This condition is typical of plastic hopper drying systems. 1. Turn the selector valve clockwise until fully closed. The valve must be fully closed to prevent ambient air from leaking in. 2. Connect the sample inlet tubing with filter to a convenient sampling location. To check a dryer s performance, sample from the dryer s output hose. To check your process material for dryness, sample from the hopper s return hose. CAUTION Do not bypass the cooling coil or cover it with insulating material. To do so will expose the sensor to elevated temperatures and may cause damage. 3. Turn the power on and allow the reading to stabilize. It may take as much as 5 to 15 minutes for the dew point to drop and 10 to 25 minutes for a reading to stabilize. You can silence the alarm with the switch on the side of the panel. When operation is done, turn power off then disconnect sample tubing. POSITIVE PRESSURE SAMPLING (ABOVE 7 PSIG) Turn selector valve counterclockwise to OPEN position. This will vent air sample after it flows through sensor chamber. Connect sample tube to sampling location. For consistent positive pressure sampling above 7 psig, contact an IMS Customer Service Representative at about Model October, 2004 Page 6 of 16

8 INSTALLATION (continued) TEST RESULTS A green light indicates a properly functioning refrigerant dryer. Very dry air will cause the Dew Point Meter and Monitor to indicate below 10 F. If the unit is sampling process air after it leaves a drying hopper filled with material, initially high dew points may be encountered. As the moisture is purged out of the material, the dew point decreases. When the Dew Point Meter and Monitor displays a High Alarm, the following conditions should be considered: 1. There is a leak in the dryer system or sampling line. 2. The dryer is overloaded by excessively wet material. 3. The dryer has experienced mechanical or electrical failure. 4. The Dew Point Meter and Monitor has failed (see ELECTRONIC TEST PROCEDURE Section on Page 9 and MAINTENANCE Section on Page 8). NOTE The built-in audible alarm can be silenced with the ALARM switch on the side of the panel. October, 2004 Page 7 of 16

9 MAINTENANCE The Dew Point Meter and Monitor normally does not require calibration, and in most applications, the sensor will provide years of service. However, the easiest and most reliable way to insure consistent accuracy is to replace the sensor annually. DANGER Live Electric Parts could cause DEATH or SHOCK Unplug meter or protect yourself from electric parts when servicing. Only Qualified Technicians are to service this meter. SENSOR REPLACEMENT PROCEDURE 1. Remove front cover and locate black sensor manifold. 2. Loosen hex nut on manifold and slide nut along wires away from manifold. 3. Lift 4-pin insert out of manifold to reveal sensor assembly. 4. Use a blunt object to pry sensor assembly out of 4-pin insert. 5. Observe the pin pattern on the new sensor assembly and match to the 4-pin insert. Use moderate finger pressure to press in the new sensor assembly. The sensor does not need to seat fully into the 4-pin insert. 6. Replace sensor assembly and 4-pin insert into manifold and hand tighten the hex nut. ALARM SET POINT ADJUSTMENT Locate the display function switch (S1) on PC Board. Refer to Mounting and Wiring Diagram on Page 14 for exact location. NOTE: Only one position of this switch should be ON at a time. 1. To view and adjust Relay #1 set point, turn the #1 Position of S1 OFF and the SET1 Position #2 ON. Turn the SET1 of P2 near the switch to the desired set point. 2. When finished adjusting the set point, return S1 to the default operating mode by turning OPER position ON and all others OFF. 3. A small red LED near the potentiometer P2 indicates when an alarm is occurring. October, 2004 Page 8 of 16

10 MAINTENANCE (continued) RECORDER OUTPUT SELECTION (TB3) For 4 to 20mA connect wires to Terminals 2 and 3 of TB3 of the PC Board. Terminals 1 and 2 are for 0 to 5 Volts. Refer to Mounting and Wiring Diagram on Page 14 for exact location. -40 F = 0 Volts or 4mA +70 F = 5 Volts or 20mA DISPLAY UNITS SELECTION - CHANGE DISPLAY FROM F TO C To change the digital display to C, use needle nose pliers and move jumpers J6 and J7 to the C position on PC Board. Refer to Mounting and Wiring Diagram on Page 14 for exact location. ELECTRONIC TEST PROCEDURE This procedure is only necessary if circuit is thought to be malfunctioning. 1. Locate jumper J5 on the board and move it away from the TC position. This disables temperature compensation. Refer to Mounting and Wiring Diagram on Page 14 for exact location. 2. Disconnect the sensor wires at terminals A and B. Check display for 1 F ± 1 F. 3. Place a jumper across sensor terminals A and B. Check display for 70 F ± 1 F. 4. Remove power and return jumper J5 to the TC position. 5. If these parameters cannot be met, contact an IMS Company Customer Service Representative at If the circuit does not function properly, the Dew Point Meter and Monitor should be returned to the factory for repair. Please contact an IMS Company Customer Service Representative at for instructions on returning equipment for repair. October, 2004 Page 9 of 16

11 REPLACEMENT PARTS DESCRIPTION OLD IMS # NEW IMS # Desiccant Tube...TEZZ Filter...TEZZ Hygrosensor...TEZZ October, 2004 Page 10 of 16

12 PARTS IDENTIFICATION Green Digital Display Red Exhaust At Or Below Above Selector Set Point Set Point Valve Indicator Indicator Alarm Alarm Switch Cooling Tube On/Off Switch Sampling Tube Chart Recorder Output Sample Exhaust Tube October, 2004 Page 11 of 16

13 PARTS IDENTIFICATION (continued) Sensor Cable Sensor Chamber Sampling Pump October, 2004 Page 12 of 16

14 ASSEMBLY DRAWING October, 2004 Page 13 of 16

15 MOUNTING AND WIRING DIAGRAM TB3 Jumper J6 Jumper J7 Jumper J5 Display Function Switch S1 October, 2004 Page 14 of 16

16 AIRFLOW SCHEMATIC October, 2004 Page 15 of 16

17 MAINTENANCE RECORDS AND NOTES October, 2004 Page 16 of 16

PORTABLE DEW POINT MONITOR

PORTABLE DEW POINT MONITOR PORTABLE DEW POINT MONITOR MODEL 8072, 8072-230VAC (units made after 2002) Table of Contents INTRODUCTION... 2 SPECIFICATIONS:... 2 OPERATION... 3 Dryer Output Sampling... 3 Hopper Output Sampling... 3

More information

Lime Buster III. Model LB-300P IMS # (CIC1-LB300P) INSTRUCTION MANUAL

Lime Buster III. Model LB-300P IMS # (CIC1-LB300P) INSTRUCTION MANUAL Lime Buster III Model LB-300P IMS # 110226 (CIC1-LB300P) INSTRUCTION MANUAL October, 2007 IMS Company 10373 Stafford Road Chagrin Falls, OH 44023-5296 Telephone: (440) 543-1615 Fax: (440) 543-1069 Email:

More information

TEMPERATURE CONTROLLER

TEMPERATURE CONTROLLER TEMPERATURE CONTROLLER Model UATC-20 Item #134360 / Item #133752 INSTRUCTION MANUAL October 2010 IMS Company 10373 Stafford Road Chagrin Falls, OH 44023-5296 Telephone: (440) 543-1615 Fax: (440) 543-1069

More information

DryAire DRYING CABINET

DryAire DRYING CABINET CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS L-72 DryAire DRYING CABINET Model LMA1053L JOB AID Part No. 8178202 FORWARD This Whirlpool Job Aid, DryAire Drying Cabinet, (Part No. 8178202), provides

More information

VSA Series Air Dryer. User s Guide

VSA Series Air Dryer. User s Guide VSA Series Air Dryer User s Guide Models covered: VSA1 VSA2 VSA3 VSA4 1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS VSA SERIES AIR DRYER! We here at PUREGAS are very proud

More information

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER 2001829 OPERATIONS AND MAINTENANCE MANUAL Prepared by: 860 Douglas Way PO Box 530 Natural Bridge Station, VA 24579 1.0 SCOPE: This Operations and Maintenance

More information

Installation. Built-in Full Height Wine Cellar VCWB301

Installation. Built-in Full Height Wine Cellar VCWB301 Installation Built-in Full Height Wine Cellar VCWB301 Table of Contents Warnings & Important Information _ 3 Dimensions _ 5 Specifications _ 6 Cutout Dimensions 7 Cabinet Information _ 8 Cabinet Information

More information

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS **WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER** Altering the product or replacing parts with non authorized factory parts voids all warranty

More information

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER 2001927 Prepared by: 860 Douglas Way PO Box 530 Natural Bridge Station, VA 24579 1 1.0 SCOPE: This

More information

Model OEM-2 INSTRUCTIONS FOR USE

Model OEM-2 INSTRUCTIONS FOR USE ECO SENSORS, INC. 3-03.2 OEM OZONE CONTROLLER Model OEM-2 INSTRUCTIONS FOR USE GENERAL The model OEM-2 is a system to control ozone generators and alarms based on an adjustable ozone concentration set

More information

Installation Instructions

Installation Instructions 50ES--A, 50EZ--A, 50VG--A, B, 50VL--A, B, 50VR--A, 50VT--A, B 604D-- --A, 607C-- --A, B, 607E-- --A, 704D-- --A, 707C-- --A, B, 707E-- --A PA3G -- -- A, PH3G -- -- A, PA4G, PH4G PAD3, PHD3, PAD4, PHD4,

More information

TSS 15/55 Hi-Lift Vacuum

TSS 15/55 Hi-Lift Vacuum TSS 15/55 Hi-Lift Vacuum OPERATOR S MANUAL 2007 ICS, Blount Inc. F/N 71335 Oct 07 TABLE OF TITLE CONTENTS SYMBOLS & LABELS 4 SAFETY 5 TECHNICAL SPECIFICATIONS 6 SET-UP 7 OPERATION 8 MAINTENANCE 9 TROUBLESHOOTING

More information

PL Series Premier Indoor Plenum Coils

PL Series Premier Indoor Plenum Coils IM-PLC-0667392-04 April 2016 PL Series Premier Indoor Plenum Coils Installation Instructions GENERAL ADP evaporator coils are designed for use with condensing units or heat pump units. These instructions

More information

INSTRUCTIONS FOR TAL SERIES VACUUM HOPPER LOADER

INSTRUCTIONS FOR TAL SERIES VACUUM HOPPER LOADER INSTRUCTIONS FOR TAL SERIES VACUUM HOR LOADER TAL-15U 150 LBS PER HOUR MAGNETIC LEVEL SWITCH TAL-3U-E 450 LBS PER HOUR SIGHT GLASS WITH PROXIMITY LEVEL SWITCH Proportional Dual Feed Valve Available TAL-6U

More information

AE R1 October to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors

AE R1 October to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors October 2017 1.5 to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors Safety Safety Instructions... 2 Safety Icon Explanation... 2 Instructions Pertaining to Risk of Electrical Shock, Fire, or Injury

More information

PORT700CF Portable Fume Collector

PORT700CF Portable Fume Collector 11975 Portland Ave. S. Suite 104 Burnsville, MN 55337 Phone: 952-894-6637 Fax: 952-894-0750 Email: info@ventaire.com Website: www.ventaire.com PRODUCT GUIDE FOR PORT700CF Portable Fume Collector REV:110314

More information

PRE-INSTALLATION PROCEDURE

PRE-INSTALLATION PROCEDURE PRE-INSTALLATION PROCEDURE Required with each BLUPURA Water Treatment System. 1 each External Filter 1 each Chiller 1 each CO 2 Regulator 1 each External Filter 1 each Water Pressure Regulator 1 each 4

More information

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION AIR SERIES SYSTEM INSTALLATION MANUAL CONTENTS CONSIDERATIONS General Plumbing Component Connection 2 2 2 ILLUSTRATION Control System 3 CONFIGURATION Voltage Verification 4 CONNECTION Component Connection

More information

Safe Operation Manual. Honeywell IQ Force Gas Detector

Safe Operation Manual. Honeywell IQ Force Gas Detector Safe Operation Manual Honeywell IQ Force Gas Detector Honeywell Analytics 800-663-4164 403-248-9226 Fax 403-575-3708 03JUN2012 P/N 50105843-047 Version 01 http://www.honeywell.com HONEYWELL IQ Force PERSONAL

More information

Intelligent cascading kit

Intelligent cascading kit Technical Service Instruction Intelligent cascading kit Kit components: Cascading cable (2X) 6720811759 / 238-51036-00A (2014/05) Table of contents Table of contents 1 Key to symbols and safety instructions............

More information

POPPI ELECTRIC HOT AIR POPPER Operation Manual

POPPI ELECTRIC HOT AIR POPPER Operation Manual 176 MITTEL DRIVE, WOOD DALE, IL 60191 POPPI ELECTRIC HOT AIR POPPER Operation Manual MODELS: POPPI12 -X 120/240 Volt, 60 Hz (C) 120/208 Volt, 60 Hz (D) 230 Volt, 50 or 60Hz (E) (R) 200 Volt, 50/60 Hz (I)

More information

AD SP. Air Dryer Maintenance Manual. Innovation with Integrity. Version 001 NMR

AD SP. Air Dryer Maintenance Manual. Innovation with Integrity. Version 001 NMR AD SP Air Dryer Maintenance Manual Version 001 Innovation with Integrity NMR Copyright by Bruker Corporation All rights reserved. No part of this publication may be reproduced, stored in a retrieval system,

More information

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS INSTRUCTION MANUAL FOR WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS DE3 - DE5 OPERATIONS GENERAL This instruction manual covers the installation, operation, maintenance and troubleshooting

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-(845-4641) or visit the Viking Web site at vikingrange.com

More information

Power Supply Display Module PSDM. Installation and Operation Manual

Power Supply Display Module PSDM. Installation and Operation Manual Power Supply Display Module PSDM Installation and Operation Manual Read this manual before using this product. Failure to follow the instructions and safety precautions in this manual can result in serious

More information

Operator's Manual. PCP October 2017

Operator's Manual. PCP October 2017 Operator's Manual PCP-0001.2 October 2017 Table of Contents Introduction...4 Intended Use...4 Safety Information...5 Specifications...7 Operating Conditions...7 Lifting and Storing...8 Installation...10

More information

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR OM117 OPERATING AND MAINTENANCE MANUAL for the G30 CARBON DIOXIDE MONITOR (Part No: G30) (Intentionally Blank) APPROVAL SHEET DIVEX MANUAL NUMBER: ADVITIUM NUMBER: DOCUMENT TITLE: OM117 GA-OM-5715 G30

More information

Installation Instructions

Installation Instructions EHNA Electric Heaters 5-20kW For 60 Hz Small Packaged Products MODELS: PAD3, PHD3, PAD4, PHD4, PAD5, PHD5, WPA3, WPH3 Installation Instructions NOTE: Read the entire instruction manual before starting

More information

Cast Iron Commercial Hot Water Or Steam Boiler

Cast Iron Commercial Hot Water Or Steam Boiler Cast Iron Commercial Hot Water Or Steam Boiler Users Information Manual UTICA BOILERS PO Box 4729 Utica, NY 13504-4729 www.uticaboilers.com An ISO 9001-2000 Certified Company P/N# 240006925U, Rev. 1.0

More information

DRI-AIR INDUSTRIES HOPPER BANK OPERATING MANUAL

DRI-AIR INDUSTRIES HOPPER BANK OPERATING MANUAL HOPPER BANK OPERATING MANUAL Page 1 DRI-AIR INDUSTRIES, INC. 16 THOMPSON ROAD P.O. BOX 1020 EAST WINDSOR, CT 06088-1020 Tel. (860) 627-5110 FAX (860) 623-4477 Internet http://www.dri-air.com e-mail: sales@dri-air.com

More information

Heater Upgrade Instructions

Heater Upgrade Instructions Heater Upgrade Instructions Important Safety Precautions It is recommended that you plug the chiller into a GFCI outlet at all times. Do not operate SeaChill chillers or any accessory to SeaChill chillers

More information

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13 R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.

More information

Unit 3 Machine Composition

Unit 3 Machine Composition Unit 3 Machine Composition Unit Objectives Given a realistic scenario in which the learner has access to the machine s internal components the learner will understand the composition and functions of the

More information

ImPress IRONING STATION

ImPress IRONING STATION CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS L-73 ImPress IRONING STATION Model LFB2611L JOB AID Part No. 8178203 FORWARD This Whirlpool Job Aid, ImPress Ironing Station, (Part No. 8178203), provides

More information

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER OPERATING MANUAL MODEL AIR 500TM AIR DRYER Puregas, LLC 226-A Commerce St. Tel: 800-52-535 Broomfield, Colorado Fax: 303-657-2205 P/N P0255 REV A, 02/9/4 TABLE OF CONTENTS.0 GENERAL... 3 2.0 SPECIFICATIONS...

More information

INSTRUCTION MANUAL. UNDERCOUNTER WINE & BEVERAGE COOLER (32 bottles capacity) MODEL:WC-30U

INSTRUCTION MANUAL. UNDERCOUNTER WINE & BEVERAGE COOLER (32 bottles capacity) MODEL:WC-30U INSTRUCTION MANUAL UNDERCOUNTER WINE & BEVERAGE COOLER (32 bottles capacity) MODEL:WC-30U To ensure proper use of this appliance and your safety, please read the following instructions completely before

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 12 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS... 5 CLEARANCES... 5

More information

Installation Instructions

Installation Instructions 50ZPB, C, 50ZHB, C, PA3Z ---A, PH3Z ---A, PA4Z, PH4Z, PAJ4,PHJ4,WJA4,WJH4 SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters 5---20 kw For 14 SEER, R---410A Manufactured Home Installation Instructions

More information

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858) User Manual AIR HOG Model: 7303L Vacuum Booster REV. 3/20/18 13655 Stowe Dr. Poway, CA 92064 P: (858) 679-1191 F: (858) 726-6005 INTRODUCTION Dear Customer: Congratulations on the purchase of your new

More information

Upright Freezer Congélateur vertical Congelador vertical

Upright Freezer Congélateur vertical Congelador vertical Installation and User Manual Manuel d installation et d utilisation Manual de instalación y del usuario HFU0100ACW Upright Freezer Congélateur vertical Congelador vertical Part # 0570000002 TABLE OF CONTENTS

More information

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350 Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others

More information

T834C Heating-Cooling Thermostat

T834C Heating-Cooling Thermostat M3375 M3375 TRADELINE T834C Heating-Cooling Thermostat Application T834C Thermostats control 4 to 30 Vac single-stage heating-cooling systems. See Table for specific models and applications. An spdt mercury

More information

FLT93 Installation, Operation and Troubleshooting Guide

FLT93 Installation, Operation and Troubleshooting Guide FLT93 Installation, Operation and Troubleshooting Guide Pre-Installation A. To get the best results from the instrument, the instrument should be mounted 20 pipe diameters downstream from any valve, pipe

More information

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE Service Facts Customer Property: Contains wiring and service information. Please retain. WC*240-SF-1H Library Service Literature Product Section Unitary Product Package Air Conditioner Model WC* Literature

More information

Refrigerant Recovery Machine. Model No Operating Manual

Refrigerant Recovery Machine. Model No Operating Manual Refrigerant Recovery Machine Model No. 25700 Operating Manual Safety Precautions WARNING : TO PREVENT PERSONAL INJURY AND / OR EQUIPMENT DAMAGE, CAUTION - Risk of injury. This equipment should only be

More information

PowerVac G Single to Twin Conversion Kit [ ]

PowerVac G Single to Twin Conversion Kit [ ] PowerVac G Single to Twin Conversion Kit [002-1371-00] warning Motors are thermally protected with automatic reset. Unit may start without warning. Caution Vac unit weighs 375 lbs (170 kgs). Use care when

More information

Duct and Rough Service Carbon Monoxide Sensor

Duct and Rough Service Carbon Monoxide Sensor Product Identification and Overview Duct and Rough Service Carbon Monoxide Sensor BAPI s Carbon Monoxide Sensor offers enhanced electrochemical sensing with outstanding accuracy at low concentrations.

More information

INSTALLATION AND OPERATING INSTRUCTIONS. For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK

INSTALLATION AND OPERATING INSTRUCTIONS. For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK INSTALLATION AND OPERATING INSTRUCTIONS For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK Congratulations on your purchase of the Reliance Controls Generator Power Transfer

More information

Installation Instructions

Installation Instructions 50ES---A, 50EZ---A, 50VL---A, 50VG---A, 50VR---A, 50VT---A, 604D--- ---A, 607C--- ---A, 607E,--- ---A, 704D--- ---A, 707C--- ---A, 707E--- ---A PA3G --- --- A, PH3G --- --- A SMALL PACKAGED PRODUCTS Electric

More information

Installation Guide. 15 W./24 W. Undercounter Refrigeration

Installation Guide. 15 W./24 W. Undercounter Refrigeration Installation Guide 15 W./24 W. Undercounter Refrigeration Table of Contents Warnings & Important Information 3 Proper Disposal 4 Dimensions (15 W. Professional) 5 Dimensions (24 W. Professional) 6 Dimensions

More information

Installation Instructions

Installation Instructions Installation Instructions Cased Horizontal Furnace Coil CK3B A96318 Fig. 1 Model CK3B Furnace Coil NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper

More information

Residential Piping and Long Line Guideline

Residential Piping and Long Line Guideline AC / HP R-410A Refrigerant Systems Single-Stage, Two-Stage and Variable Speed Models Residential Piping and Long Line Guideline TABLE OF CONTENTS Safety Considerations... 2 Definitions... 2 Introduction...

More information

MODEL DPS1 Heated Dew Point Measuring System OPERATORS MANUAL

MODEL DPS1 Heated Dew Point Measuring System OPERATORS MANUAL MODEL DPS1 Heated Dew Point Measuring System OPERATORS MANUAL 19 Brigham Street Unit #8 Marlborough, MA USA 01752 Tel: (508) 263-5900 (800) 276-3729 Fax: (508) 486-9348 E-mail: h2o@edgetech.com www.edgetech.com

More information

AD XT. Air Dryer Service Manual. Innovation with Integrity. Version 003 NMR

AD XT. Air Dryer Service Manual. Innovation with Integrity. Version 003 NMR AD XT Air Dryer Service Manual Version 003 Innovation with Integrity NMR Copyright by Bruker Corporation All rights reserved. No part of this publication may be reproduced, stored in a retrieval system,

More information

Installation Instructions

Installation Instructions CRHEATER270A00 - ELECTRIC HEATER ACCESSORY SINGLE PACKAGE ROOFTOP UNITS 15 to 27.5 TONS Installation Instructions TABLE OF CONTENTS SAFETY CONSIDERATIONS... 1 GENERAL... 1 MODEL/CAPACITY TABLES... 2-11

More information

Installation Instructions Part No , Part No Part No

Installation Instructions Part No , Part No Part No Torsion-Flex Motor mount for PSC motors and Rigid-Mount for ECM motors Replacement Kit Cancels: New Installation Instructions Part No. 327752-401, Part No. 327753-401 Part No. 327754-401 IIK-310A-45-11

More information

Fig. 1 - Unit PGD4, PGS4, WPG4

Fig. 1 - Unit PGD4, PGS4, WPG4 OWNER S MANUAL 14 SEER Single -Package Air Conditioner and Gas Furnace System with R -410A Refrigerant Single Phase 2 to 5 Nominal Tons Three Phase 3 to 5 Nominal Tons PGD4andPGS4SeriesE,WPG4SeriesB Fig.

More information

Installation Instructions

Installation Instructions Installation Instructions For Fully Integrated NoFrost Combined Refrigerator-Freezers HCB 1560/1561 7084 429-00 Important Please read and follow these instructions These instructions contain Danger, Warning

More information

MODEL T25226 PORTABLE MEAT GRINDER INSTRUCTION MANUAL (For models manufactured since 11/12)

MODEL T25226 PORTABLE MEAT GRINDER INSTRUCTION MANUAL (For models manufactured since 11/12) MODEL T25226 PORTABLE MEAT GRINDER INSTRUCTION MANUAL (For models manufactured since 11/12) LISTED WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT THE WRITTEN APPROVAL

More information

Hoshizaki America, Inc.

Hoshizaki America, Inc. Hoshizaki America, Inc. Stackable Crescent Cuber Models KM-1601SAH/3 KM-1601SWH/3 KM-1601SRH/3 A Superior Degree of Reliability SERVICE MANUAL www.hoshizaki.com Number: 73145 Issued: 10-31-2006 Revised:

More information

Installation Instructions

Installation Instructions 38MHR Outdoor Unit Single Zone Ductless System Sizes 09 to 24 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. NOTE: Images are for illustration purposes

More information

Cambridge Engineering, Inc. 24 S-Series Technical Manual

Cambridge Engineering, Inc. 24 S-Series Technical Manual Start-Up Instructions START-UP PROCEDURE 1. Visual Inspection Of Equipment (page 24) 2. Electrical Supply Voltage Verification (page 24) 3. Gas Supply Pressure Verification (page 24) 4. Blower Rotation

More information

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump Packaged Heat Pumps Owner s Guide to Operating and Maintaining Your Heat Pump NOTE TO EQUIPMENT OWNER: For your convenience, please record the model and serial numbers of your new equipment in the spaces

More information

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA TXV Coils for Manufactured Housing EMA NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance,

More information

Instruction Sheet. DANGER Indicates a potentially or imminently hazardous situation which, if not avoided, will result in death or serious injury.

Instruction Sheet. DANGER Indicates a potentially or imminently hazardous situation which, if not avoided, will result in death or serious injury. Instruction Sheet DOC306.53.00742 Safety information Please read this entire document before unpacking, setting up or operating this equipment. Pay attention to all danger and caution statements. Failure

More information

D Carousel Dryer - DC-1

D Carousel Dryer - DC-1 www.conairnet.com USER GUIDE UGD024/0304 D Carousel Dryer - DC-1 Models 15, 25, 50, 75, and 100 with DC-1 Controls INTRODUCTION Purpose of the User Guide How the guide is organized Your responsibilities

More information

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats. Three Phase Simplex Installation Instructions and Operation/Troubleshooting Manual This control panel must be installed and serviced by a licensed electrician in accordance with the National Electric Code

More information

GDDEM10 DEHUMIDIFIER

GDDEM10 DEHUMIDIFIER GDDEM10 DEHUMIDIFIER SOCIABLE REMARK When using this dehumidifier in the European countries, the following information must be followed: DISPOSAL: Do not dispose this product as unsorted municipal waste.

More information

Installation Instructions

Installation Instructions CNPVP CNRVP Cased N Coils Upflow --- Downflow Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

More information

690 and Power Fishing Systems

690 and Power Fishing Systems INSTRUCTION MANUAL 690 and 690-22 Power Fishing Systems Includes Serial Number AAR 3800 and higher (120 volt model) Includes Serial Number AAT 00500 and higher (220 volt model) Read and understand all

More information

APC BC300 Series 40kW 208/450/480V User Guide

APC BC300 Series 40kW 208/450/480V User Guide APC BC300 Series 40kW 208/450/480V User Guide Copyright 2002 APC Denmark ApS This manual is subject to change without notice and does not represent a commitment on the part of the vendor Thank You Thank

More information

VERNON ELECTRIC FIREPLACE

VERNON ELECTRIC FIREPLACE VERNON ELECTRIC FIREPLACE MODEL # 60351 CARE & USE GUIDE Please read this manual before installing and using your fireplace. IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, AN ELECTRICAL SHOCK

More information

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

Owner s Manual Refrigerated Compressed Air Dryer Model F-50 Owner s Manual Refrigerated Compressed Air Dryer Model F-50 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all

More information

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator.

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator. Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N260.3 - a 2.4 cu. ft., 3-way refrigerator. NORCOLD, Inc. P.O. Box 4248 Sidney, OH 45365-4248 Part No. 619260A (4-98) Table

More information

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual This manual covers operation of the tcm100 and tcm101 Series Temperature Control Modules.

More information

MODEL MW200 MODEL MW600 AIR DRYER

MODEL MW200 MODEL MW600 AIR DRYER OPERATING MANUAL MODEL MW200 MODEL MW600 AIR DRYER Mail Address: 226A Commerce St. Tel: 303-465-3063 Broomfield, CO 80020 Fax: 303-465-9294 TABLE OF CONTENTS 1.0 GENERAL...3 2.0 SPECIFICATIONS...3 3.0

More information

Model 1062 Environment Monitor

Model 1062 Environment Monitor Model 1062 Environment Monitor Continuously Monitors Environment Temperature Humidity Barometric Pressure Line Voltage Line Frequency Applications Manufacturing The 1062A Environment Monitor will ensure

More information

MDH Series Air Dryer. User s Guide

MDH Series Air Dryer. User s Guide MDH Series Air Dryer User s Guide Models covered: MDH1 MDH2 MDH3 MDH4 MDH5 MDH6 1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS MDH SERIES AIR DRYER! We here at PUREGAS

More information

Installation Guide. 15 W./24 W. Undercounter Refrigeration U L. Viking Range Corporation. 111 Front Street. Greenwood, Mississippi USA

Installation Guide. 15 W./24 W. Undercounter Refrigeration U L. Viking Range Corporation. 111 Front Street. Greenwood, Mississippi USA Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-845-4641 U L C U L 15 W./24 W. Undercounter Refrigeration

More information

Important: Read all instructions and warnings carefully before starting installation. INSTALLATION INSTRUCTIONS GENERAL

Important: Read all instructions and warnings carefully before starting installation. INSTALLATION INSTRUCTIONS GENERAL Thank you for purchasing a Fire Sense Electric Fireplace. Important: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible

More information

Installation Instructions

Installation Instructions 40MHH High Wall Ductless System Sizes 09 to 24 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. NOTE: Images are for illustration purposes only. Actual

More information

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge ENSPECO Recovery/ Recycle/ Evacuate/ Recharge RMS 3012 RMS 3034 Approved by UL/SAE to J-1991 R12 Purity Standards Approved by UL/SAE to J-2210 R134 Purity Standards This semi-automatic machine will recover

More information

TECHNICAL NOTICE GH/GHO/GAE V

TECHNICAL NOTICE GH/GHO/GAE V TECHNICAL NOTICE GH/GHO/GAE V1.0-02.14 INDUSTRIAL COOLING UNITS Identification Marksa SA Industrial cooling 39, avenue du Technicum CH-2400 Le Locle Version Date Modifications 1.0 14.02.14 First edition

More information

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ Operation & Maintenance Manual Table of Contents: 1.0 Introduction 1 2.0 Unpacking your COOL- SPACE 1 3.0 Set-up

More information

IQ/OQ Protocol Installation Qualification/ Operation Qualification

IQ/OQ Protocol Installation Qualification/ Operation Qualification IQ/OQ Protocol Installation Qualification/ Operation Qualification ZZ FreeZone Freeze Dry Systems (To be used with some FreeZone Systems manufactured prior to August, 2004- see model number chart inside)

More information

Installation Instructions

Installation Instructions 40MAQ High Wall Ductless Split System Sizes 09 to 36 Installation Instructions NOTE: Read the entire instruction manual before starting the installation TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS 2 PARTS

More information

Owner s Information Manual

Owner s Information Manual 48ES---A and 48VL---A Comfort and Performance 13 and 14 SEER Single Packaged Air Conditioner and Gas Furnace System With Puron (R---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 24---60)

More information

Installation Instructions

Installation Instructions Installation Instructions EHMA SERIES ELECTRIC HEATERS FOR PAM3 SERIES PACKAGE AIR CONDITIONERS PHM3 SERIES PACKAGE HEAT PUMPS TABLE OF CONTENTS SAFE INSTALLATION REQUIREMENTS... 2 GENERAL INFORMATION...

More information

HEAT PUMP INSTALLATION MANUAL

HEAT PUMP INSTALLATION MANUAL DUCTLESS INVERTER HEAT PUMP INSTALLATION MANUAL Models: TERRA09HP230V1A TERRA12HP230V1A TERRA18HP230V1B TERRA24HP230V1B Thank you for choosing a Gree Terra Ductless Heat Pump for your customer. Please

More information

Explorer F210 Fuel Instrument Installation and Operation Manual

Explorer F210 Fuel Instrument Installation and Operation Manual Explorer F210 Fuel Instrument Installation and Operation Manual www.northstarnav.com 2 Northstar Explorer F210 Installation and Operation Manual IMPORTANT SAFETY INFORMATION Please read carefully before

More information

Fig. 1 - Unit PHD4 and WPH4

Fig. 1 - Unit PHD4 and WPH4 OWNER S MANUAL 14 SEER Single -Package Heat Pump System with R -410A Refrigerant Single Phase and Three Phase 2 to 5 Nominal Tons PHD4 Series F and WPH4 Series B Fig. 1 - Unit PHD4 and WPH4 A09034 NOTE

More information

OPERATION & MAINTENANCE MANUAL TC670

OPERATION & MAINTENANCE MANUAL TC670 OPERATION & MAINTENANCE MANUAL TC670 Refrigerant Management Center (Convertible For Use With R12 or R134a) RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80342-02 TC670 CONVERTIBLE

More information

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG) WET/DRY VACUUM Operating Instructions (ENG) MODEL: T1 y QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO 9001. Read these instructions before operating the machine.

More information

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual ANALOX 5001 ANALOX 5001 Carbon Dioxide Monitor User Manual Analox Sensor Technology Ltd 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT T: +44 (0)1642 711400 F: +44 (0)1642 713900

More information

RINGMASTER 5-1/2 & 7 COTTON CANDY MACHINE

RINGMASTER 5-1/2 & 7 COTTON CANDY MACHINE 3243 North California Avenue, Chicago, IL 60618 RINGMASTER 5-1/2 & 7 COTTON CANDY MACHINE 120 Volt, Single Phase, 50/60 Cycle 230 Volt, Single Phase, 50 Cycle READ and UNDERSTAND these operating, servicing,

More information

Using the Model 1500 Portable Chilled Mirror Hygrometer

Using the Model 1500 Portable Chilled Mirror Hygrometer APPLICATION NOTE 2016_0120 MODEL 1500 Rev C Using the Model 1500 Portable Chilled Mirror Hygrometer The Model 1500 is a portable, multi-function, optical chilled mirror hygrometer designed to accurately

More information

Flopurge TS. Operation Manual

Flopurge TS. Operation Manual Flopurge TS Operation Manual Part Number 079-0204 Spectron Gas Control Systems United Kingdom Unit 4, Herald Court, University of Warwick Science Park, Coventry, CV4 7EZ +44 (0)24 7641 6234 sales@spectron-gcs.com

More information

INSTRUCTION MANUAL FOR DUTCHESS MODEL 260 BAGEL & BUN SLICER

INSTRUCTION MANUAL FOR DUTCHESS MODEL 260 BAGEL & BUN SLICER INSTRUCTION MANUAL FOR DUTCHESS MODEL 260 BAGEL & BUN SLICER Table of Contents Safety Information I thru VII Uncrating Instructions 1 Introduction 2 Adjustment Instructions 3 Operating Instructions, Cleaning,

More information

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system. READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system. Attention Installer: Please be sure this manual and warranty information

More information

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS: OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS: 79202-00 79202-05 79202-30 79202-35 Approval Agency s Model 79202-00 & 79202-05 Model 79202-30 & 79202-35 Not recommended for pumping acid,

More information