Datasheet - AZM 161SK-12/12RK-024

Size: px
Start display at page:

Download "Datasheet - AZM 161SK-12/12RK-024"

Transcription

1 Print - Create PDF - Create EXCEL file - Hide system components :21:41h Datasheet - AZM 161SK-12/12RK-024 Solenoid interlock / AZM 161 thermoplastic enclosure Double-insulated Interlock with protection against incorrect locking. 130 mm x 90 mm x 30 mm 6 Contacts Long life Large wiring compartment Manual release cable entries 4 M 16 x 1.5 (Minor differences between the printed image and the original product may exist!) Ordering details Product type description AZM 161SK-12/12RK-024 Article number EAN code Approval Approval BG USA/CAN CCC Classification Standards EN ISO B10d Opener (NC) Mission time 20 Years notice Global Properties Product name AZM 161 Standards EN , BG-GS-ET-19 Compliance with the Directives (Y/N) Number of actuating directions Yes 3 piece

2 Active principle electromechanical Duty cycle Magnet 100 % Materials - Material of the housings Plastic, glass-fibre reinforced thermoplastic, self-extinguishing - Material of the contacts Silver Housing coating None Weight 500 g Mechanical data Actuating play in direction of actuation 5.5 mm Design of electrical connection Screw connection Cable section - Min. Cable section 1 x 0,75 mm² - Max. Cable section 1 x 1.5 mm² Mechanical life > operations Emergency unlocking device (Y/N) No Manual release (Y/N) Yes Emergency release (Y/N) No Latching force 30 N Positive break force 20 N positive break travel 10 mm Clamping force Fmax 2000 N Max. Actuating speed 2 m/s Actuating frequency max / h notice All indications about the cable section are including the conductor ferrules. Ambient conditions Ambient temperature - Min. environmental temperature - 25 C - Max. environmental temperature + 60 C Protection class IP67 to IEC/EN Electrical data Design of control element Switching principle Number of auxiliary contacts Number of safety contacts Power to unlock Power to lock Rated control voltage Us Power consumption Rated impulse withstand voltage Uimp Rated insulation voltage Ui Thermal test current Ithe Normally open contact (NO), Opener (NC) Creep circuit element 2 piece 4 piece Yes No 24 VAC/DC max. 10 W 4 kv 250 V Utilisation category AC-15: 230 V / 4 A, DC-13: 24 V / 2,5 A Max. fuse rating 6 A gg D-fuse To DIN EN A ATEX Explosion protection categories for gases None

3 Explosion protected category for dusts None Miscellaneous data Applications sliding safety guard, removable guard, hinged safety guard Dimensions Dimensions of the sensor - Width of sensor 130 mm - Height of sensor 90 mm - Length of sensor 30 mm notice Manual release For maintenance, installation, etc. For manual release using M5 triangular key, available as accessory Diagram Note Diagram positive break NC contact active no active Normally-open contact Normally-closed contact Switch travel diagram

4 Notes Switch travel diagram Contact closed Contact open Setting range Break point Positive opening sequence/- angle VS adjustable range of NO contact VÖ adjustable range of NC contact N after travel Ordering suffix The applicable ordering suffix is added at the end of the part number of the safety switch. Order example: AZM 161SK-12/12RK-024G...G Protected against incorrect polarity and voltage spikes. limited terminating space 0,75 mm² Diagram 14 guard open VDC 63 0 VDC 64 unlocked Ordering code AZM 161 (1)-(2)(3)K(4)-(5)-(6)(7) (1) SK CC ST Screw connection Cage clamps male connector M12, 8- and 4-poles (Only for Us: 24 VAC/DC) (2) 12/12 2 Normally open contact (NO) / 4 Opener (NC) 12/11 2 Normally open contact (NO) / 3 Opener (NC) (Plug-in connection) 11/12 2 Normally open contact (NO) / 3 Opener (NC) (Plug-in connection) (3) without R (4) without A Latching force 5 N Latching force 30 N Power to unlock Power to lock (5)

5 without ED EU T TD TU N Manual release lateral Manual release cover-side Manual release rear Emergency exit lateral Emergency exit cover-side Emergency exit rear Emergency release (6) 024 Us: 24 VAC/DC 110/230 Us: 110/230 VAC (7) G with LED (Only for Us: 24 VAC/DC) Documents Operating instructions and Declaration of conformity (jp) 1 MB, Operating instructions and Declaration of conformity (fr) 752 kb, Operating instructions and Declaration of conformity (es) 711 kb, Operating instructions and Declaration of conformity (en) 751 kb, Operating instructions and Declaration of conformity (nl) 659 kb, Operating instructions and Declaration of conformity (de) 421 kb, Operating instructions and Declaration of conformity (it) 706 kb, BG-test certificate (de) 219 kb, BG-test certificate (en) 219 kb, CCC certification (en) 747 kb, CCC certification (cn) 725 kb, notice (de, en) 88 kb, Images

6 Dimensional drawing (basic component) Dimensional drawing (basic component) Operating principle System components Actuator AZM 161-B AZM 161-B1E

7 AZM 161-B1ES AZM 161-B1F AZM 161-B1S AZM 161-B WITH BALL LATCH AZM 161-B WITH MAGNETIC LATCH AZM 161-B AZM 161-B WITH CENTERING GUIDE

8 AZM 161-B WITH CENTERING GUIDE For very smal actuating radii AZM 161-B6S AZM 161-B6 For very smal actuating radii Door-handle system AZM 161-STS30 Latching handle Suitable for all types of guard Accessories TRIANGULAR KEY M5 For manual release using M5 triangular key, available as accessory For maintenance, installation, etc. K.A. Schmersal GmbH, Möddinghofe 30, D Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am :21:42h Kasbase DBI

Datasheet - AZM 161SK-12/12RK-024

Datasheet - AZM 161SK-12/12RK-024 30.10.2017-13:15:19h Datasheet - AZM 161SK-12/12RK-024 Solenoid interlock / AZM 161 Preferred typ Thermoplastic enclosure Double-insulated Interlock with protection against incorrect locking. 130 mm x

More information

Datasheet - AZM ZRK 24 VAC/DC

Datasheet - AZM ZRK 24 VAC/DC Print - Create PDF - Create EXCEL file - Hide system components 21.04.2011-10:13:56h Datasheet - AZM 170-02ZRK 24 VAC/DC Solenoid interlock / AZM 170 thermoplastic enclosure Double-insulated Compact design

More information

Datasheet - AZM ZRK 24 VAC/DC Solenoid interlock / AZM 170

Datasheet - AZM ZRK 24 VAC/DC Solenoid interlock / AZM 170 http://www.schmersal.net/datenblatt?lang=en&produkt=ax4732937owob0f8o2640384... 29/09/2011 Datasheet - AZM 170-11ZRK 24 VAC/DC Solenoid interlock / AZM 170 Preferred typ thermoplastic enclosure Double-insulated

More information

Datasheet - TVS /B-M20

Datasheet - TVS /B-M20 Print - Create PDF - Create EXCEL file 21.04.2011-16:21:01h Datasheet - TVS 400-12/B-M20 Safety switch for hinged guards / Hinge safety switch / TVS 400 / TESZ thermoplastic enclosure Double-insulated

More information

Datasheet - MZM 100 ST2-1P2PWREM-A

Datasheet - MZM 100 ST2-1P2PWREM-A 30.05.2015-14:45:08h Datasheet - MZM 100 ST2-1P2PWREM-A Solenoid interlock / MZM 100 Preferred typ Guard locking monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating

More information

Datasheet - MZM 100 ST-SD2PREM-A

Datasheet - MZM 100 ST-SD2PREM-A 19.03.2014-10:31:42h Datasheet - MZM 100 ST-SD2PREM-A Solenoid interlock / MZM 100 Preferred typ Guard locking monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating

More information

Datasheet - MZM 100 B ST2-SD2PREM-A

Datasheet - MZM 100 B ST2-SD2PREM-A 30.05.2015-14:46:12h Datasheet - MZM 100 B ST2-SD2PREM-A Solenoid interlock / MZM 100 Preferred typ Actuator monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating

More information

SLC 220 E/R RFBS

SLC 220 E/R RFBS 26.10.2016 09:10:02h Datasheet SLC 220 E/R0325 30 RFBS Safety light curtains, Safety light grids / Safety light curtains / SLC 220 Protection class IP65 Safety type 2 in accordance with IEC 61496 1 Resolution

More information

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content 8 Appendix 8.1 Wiring examples...4 8.2 Start configuration...4 8.3 Sensor configuration...4 8.4 Actuator configuration...5 Operating instructions.............pages 1 to 6 Original 9 EU Declaration of conformity

More information

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document 1 About this document Operating instructions... pages 1 to 6 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information you need for

More information

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net. TV8S 521 1 About this document Operating instructions... pages 1 to 6 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information you

More information

One giant leap for safety: AZM400.

One giant leap for safety: AZM400. One giant leap for safety: AZM400. Holding force: Unlocking against lateral force: Mechanical life: Protection class: Dimensions: Supply voltage: Electrical connection: AZM400 10,000 N 300 N > 1,000,000

More information

Conformity Approvals Rated insulation voltage Ui

Conformity Approvals Rated insulation voltage Ui GIOVENZANA INTERNATIONAL B.V. GENERAL CHARACTERISTICS ELECTRICAL CHARACTERISTICS CONTACT BLOCKS CAM SWITCHES Giovenzana International B.V., widely recognized as a leader in elevator technology and the

More information

PROTECT SRB 200EXi-1A

PROTECT SRB 200EXi-1A 2 Installation up to zone 1/21 J S L1 0V X1 X3 S11 S12 S21 S22 Installation up to zone 2 A1 F1 F2 U B U EXi U i 0V S12 S22 X1 X3 K1 Logic K2 K1 K2 13 23 U EXi SRB 200EXi U B -1A U i K1 K2 PA PA A1 A2 13

More information

Overload relays. General descriptions. Configuration of the front

Overload relays. General descriptions. Configuration of the front Overload relays General descriptions Type MT, bimetal-style, overload relays are designed to protect AC circuits and motors against overloads, phase failure, long starting times and prolonged stalling

More information

ISIS SAFETY SYSTEM Installation guide

ISIS SAFETY SYSTEM Installation guide ISIS SAFETY SYSTEM Installation guide CAUTION This information is designed to help suitably qualified personnel install and operate Mechan Safety equipment. Before using this product, read this guide thoroughly

More information

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO MICRO SWITCH Key Actuated Safety Switches GKN Series 004740 Issue 3 Datasheet FEATURES Red switch body for easy safety recognition Four different styles of stainless steel actuator keys Three conduits

More information

Original operating instructions Safety switch with guard locking AC901S AC902S

Original operating instructions Safety switch with guard locking AC901S AC902S Original operating instructions Safety switch with guard locking AC901S AC902S 7390914/03 01/2017 Contents 1 Preliminary note...4 1.1 Explanation of symbols...4 2 Safety instructions...4 3 Items supplied...5

More information

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description Three phase AC pumps and ventilators soft starter Description Benefits Easy to use. The is equipped with a self-learning algorithm that automatically adjusts the start parameters to optimise the motor

More information

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE Cat. N STOP & GO automatic resetting 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat. N (s) : 4 062 88 / 4 062 89 CONTENTS PAGE 1. Description - Use... 1 2. Product

More information

Switches compliant with ATEX directive

Switches compliant with ATEX directive Switches compliant with ATEX directive General Catalogue - Technical concepts page Position switches FD / FL series page 9 / Category Zone EPL Approvals 2G Gb Mb II 2G Ex ia IIC T6 Gb I Ex ia I Mb Product

More information

Safety in system: Protection for man and machine Innovations 2016/2017

Safety in system: Protection for man and machine Innovations 2016/2017 Safety in system: Protection for man and machine Innovations 2016/2017 Schmersal Safety Installation Systems The right solution for every application The new Schmersal Safety Installation System provides

More information

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet 1 About this document... pages 1 to 8 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and

More information

5 m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NBMX-21-05

5 m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NBMX-21-05 Explosion proof Non-contact Safety Switches Explosion proof reed non-contact switches monitor the status of guarding doors in petro-chemical and food applications with explosive atmospheres. Based on reed

More information

Multifunctional Gate Box MGB. More than safety.

Multifunctional Gate Box MGB. More than safety. Multifunctional Gate Box MGB More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 98. Around the world the Swabian specialists

More information

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules Engineering Guideline pac-carriers Type 9195 SIEMENS ET-200M Fail-safe signal modules pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015 pac-carrier Type 9195 Integration of conventional

More information

TCS5JBL & TCS5JBLA. Low-Voltage Top-Up Switch

TCS5JBL & TCS5JBLA. Low-Voltage Top-Up Switch 3P Technik TCS5JBL & TCS5JBLA Low-Voltage Top-Up Switch Installation and Operation Manual 3P TCS5JBL/TCS5JBLA Page 1 11/09/16 Table of Contents Description Of Operation...2 Installation...2 Safety Precautions...2

More information

Soft Starter Centrifugal Pump Soft Starter Series

Soft Starter Centrifugal Pump Soft Starter Series Soft Starter Centrifugal Pump Soft Starter Series Type RSWT Optimised algorithm for centrifugal pumps Simple User Interface 3-phase controlled Internally bypassed Multi voltage operation Integrated overload

More information

Stego accessories for cabinets

Stego accessories for cabinets www.klinkmann.com Stego accessories for cabinets page Small semiconductor Heater RC 016 2 Touch-Safe Small Heater CSK 060 3 Semiconductor Heater HG 140 4 Hazardous area Heater CREx 020 5 Touch-Safe Heater

More information

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel PROTECTOWIRE FireSystems Features Easily expandable Two supervised audible circuits Lamp and system trouble circuit test Ground fault detection Initiating device circuit (IDC) alarm test Monitors up to

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES SECTION 26 36 23 AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC Engineering Guideline pac-carriers Type 9195 for TRICON system TRICONEX TMR PLC 2 Engineering Guideline TRICON system 14.10.2009 Content Signal type Control system I/O cards type pac-carrier Channels Slots

More information

LOVAG TEST INSTRUCTION IEC/EN

LOVAG TEST INSTRUCTION IEC/EN LOVAG TEST INSTRUCTION IEC/EN 60947-5-5 CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS- ELECTRICAL EMERGENCY STOP DEVICE WITH MECHANICAL LATCHING FUNCTION This test instruction is based on the following

More information

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS Safety Control Modules for Emergency Stop Circuits TYPICAL APPLICATIONS APPROVALS DIMENSIONS Single Channel Emergency Stop Module E-Stop circuits up to Category 2 (EN 954-) Sliding door protection Conveyors

More information

RSGD. Three phase AC motor soft starter. Benefits. Description

RSGD. Three phase AC motor soft starter. Benefits. Description Three phase AC motor soft starter Description Benefits Easy to use. The is equipped with a self-learning algorithm that automatically adjusts the start parameters to optimise the motor starts and stops.

More information

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards.

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards. 7% Plugs & sockets I Industrial plugs and sockets Scame I-1 5 Industrial switched sockets Scame I-4 6 Distribution boards Scame I-7 8 Industrial plug adaptors Scame I-8 Weatherproof switches and sockets

More information

Operating Manual MS220KA and MSR220KA

Operating Manual MS220KA and MSR220KA Temperature Relays and MINIKA, Mains Monitoring, Digital Panel meters MINIPAN, Switching Relays and Controls Operating Manual MS220KA and MSR220KA ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße

More information

Easy installation Certified for zones 1 and 21 High IP degree of protection

Easy installation Certified for zones 1 and 21 High IP degree of protection Actuating elements Features Easy installation Certified for zones 1 and 21 High IP degree of protection A large number of variants and versions of actuating elements are available for the ComEx control

More information

Flostop TS D7E and A8E. Operation Manual

Flostop TS D7E and A8E. Operation Manual Flostop TS D7E and A8E Operation Manual United Kingdom Spectron Gas Control Systems Ltd, Unit 4, ATU1, University of Warwick science Park, Coventry, +44 (0) 24 7641 6234 sales@spectron-gcs.com Germany

More information

LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE

LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE MODIFICATIONS TO: ADAMS RITE ARROW CORBIN RUSSWIN DORMA DOROMATIC MONARCH PRECISION SARGENT VON DUPRIN YALE and more SERIES 1500 EXIT DEVICES CATALOG

More information

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres Z31.0.XX.6C-11 Temperature Probe for potentially explosive atmospheres (Measuring ranges from -200 to +900 C) Operating Manual GTF 103-Ex 0081 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße

More information

MICRO SWITCH GSX Series

MICRO SWITCH GSX Series MICRO SWITCH GSX Series Explosion-Proof Safety Switch DESCRIPTION Honeywell Sensing and Control MICRO SWITCH GSX Series Explosion-Proof Safety Switches combines the worldclass MICRO SWITCH global safety

More information

Safety Rope Pull Switches SRM, SR. General information on safety rope pull switches

Safety Rope Pull Switches SRM, SR. General information on safety rope pull switches Safety Rope Pull Switches SRM, SR SRM SR General information on safety rope pull switches The series SR and SRM safety rope pull switching devices developed and manufactured by BERNSTEIN AG are designed

More information

Latch key safety limit switches Technical data

Latch key safety limit switches Technical data Latch key safety Safety General Data Standards IE 6047-1, IE 6047-5-1, EN 6047-1, EN 6047-5-1, UL 508, and SA 22-2 No. 14 ertifications - Approvals UL and SA Air temperature near the device during operation

More information

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance. RFID Non-contact Safety Switches RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance. Based on RFID technology,

More information

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc User manual Explosion-safe window air conditioning system Type series AR-054 II 3 G Ex ic nac h IIC T3 Gc 1. Safety Instructions The window air conditioning series AR-054 is an explosion-safe product suitable

More information

ATEX Safety Switches. More than safety.

ATEX Safety Switches. More than safety. ATEX Safety Switches More than safety. AUDIN - 8, avenue de la malle - 5370 Saint Brice Courcelles Tel : 03.6.0.0. - Fax : 03.6.0.8.0 - Web : http: www.audin.fr - Email : info@audin.fr ATEX products from

More information

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl enproteko.com Temperature Monitoring Relay K8AB-TH Compact and Slim Relay Ideal for Temperature Alarms and Monitoring Excessive increases can be prevented and abnormal s can be monitored. Temperature monitoring

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm

More information

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE Insulation monitoring device with integrated load and temperature monitoring and locating current injector for insulation fault location systems for medical IT systems _D00043_02_D_XXEN/09.2016 Insulation

More information

Thermal Management Products & Accessories for Enclosures

Thermal Management Products & Accessories for Enclosures Thermal Management Products & Accessories for Enclosures Photo: STEGO International Headquarters in Germany STEGO, Inc. 1395 S. Marietta Parkway Building 800 Marietta, GA 30067 Tel: (770) 984-0858 Fax:

More information

BKA-EN Fire Damper. Additional operating instructions according to

BKA-EN Fire Damper. Additional operating instructions according to Additional operating instructions according to BKA-EN Fire Damper Contents GENERAL CONDITIONS... 1 DESCRIPTION... 3... 4 EC Certificate of Conformity 0761 CPD 0244 Declaration of Performance 09-19-DoP-BKA-EN-2013-07-01

More information

Original instructions Sense7-series Non-contact coded safety switch

Original instructions Sense7-series Non-contact coded safety switch Original instructions Sense7-series Non-contact coded safety switch ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/lowvoltage Read and understand this document Please

More information

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS Engineering Guideline pac-carriers Type 9195 for Yokogawa ProSafe-RS 2 Engineering Guideline / Yokogawa ProSafe-RS 06.06.2017 Integrated solutions for Yokogawa R. STAHL offers a wide range of customized

More information

SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS)

SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS) SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS) PART 1 GENERAL 1.01 Scope Furnish and install manual transfer switches (3MTS) with number of poles, amperage, voltage, and withstand

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 5 mm flush Usable up to SIL2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching element

More information

BERNSTEIN Safety Rope Pull Switches SR and SRM

BERNSTEIN Safety Rope Pull Switches SR and SRM BERNSTEIN Safety Rope Pull Switches SR and SRM For safety on the production line BERNSTEIN Safety Rope Pull Switches For more safety on the production line Whether on the conveyor belt or on the machine

More information

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION Sensing and Internet of Things Non-Contact Switches FF6 Series DESCRIPTION Honeywell FF6 Series are magnetically actuated noncontact safety limit switches for use in machine guarding applications, designed

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT

More information

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265.

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265. GETTING STARTED GUIDE NI 9265 4-Channel, 0 ma to 20 ma, 16-Bit Analog Output Module This document explains how to connect to the NI 9265. Note Before you begin, complete the software and hardware installation

More information

Earth-Rite II PLUS Static Earthing System

Earth-Rite II PLUS Static Earthing System READ MANUAL BEFORE COMMENCING WITH INSTALLATION EN Earth-Rite II PLUS Static Earthing System P1 PLUS - DC Supply Installation & Operating Instructions The safety of any system incorporating the equipment

More information

SensaGuard TM Integrated Latch Installation Instructions

SensaGuard TM Integrated Latch Installation Instructions TM Integrated Latch Installation Instructions Certifications IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE Note: Refer to Technical Specifications for Certification information and ratings. 2 TM Installation

More information

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply   - Tel: Systems Index Systems - Systems Systems...1 -.16 General information Description...1 System description...2 Overview...3 Ordering details Arc monitor with detectors...4 Current sensing unit...5 Technical

More information

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems RCMA420_D00059_01_D_XXEN/06.2016 LINETRAXX RCMA420 Residual current monitor for monitoring AC,

More information

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.

More information

DICTATOR Hold-Open Systems for Hazardous Areas

DICTATOR Hold-Open Systems for Hazardous Areas DICTATOR for Hazardous Areas Products to be used in hazardous areas obviously have to meet special demands. The European ATEX directives (first the EN 94/9/EG and then the directive 2014/34/ EU) brought

More information

BSK-RPR Fire Damper. Additional operating instructions according to

BSK-RPR Fire Damper. Additional operating instructions according to Additional operating instructions according to BSK-RPR Fire Damper Contents GENERAL CONDITIONS... 1 DESCRIPTION... 3... 4 EC Certificate of Conformity 0761 CPD 0245 Declaration of Performance 09-22-DoP-BSK-RPR-2013-07-01

More information

RE-PR3-E-27 3-Phase Panel Mount 27kW

RE-PR3-E-27 3-Phase Panel Mount 27kW Page 1 of 6 RE-PR3-E-27 3-Phase Panel Mount 27kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting

More information

HMN-D2 Insert Series

HMN-D2 Insert Series HMN-D2 Insert Series Table of contents 1. SCOPE... 2 1.1. Content... 2 1.2. Qualification... 2 2. APPLICABLE DOCUMENTS... 2 2.1. TE Connectivity Documents... 2 2.2. Other Documents... 2 3. REQUIREMENTS...

More information

Gas cylinder scale Model GCS-1

Gas cylinder scale Model GCS-1 Electronic pressure measurement Gas cylinder scale Model GCS-1 WIKA data sheet PE 87.19 Applications Level measurement of liquid gases in gas cabinets and gas distribution systems Level measurement in

More information

Original instructions JSNY7 Magnetic switch

Original instructions JSNY7 Magnetic switch Original instructions JSNY7 Magnetic switch ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.jokabsafety.com Read and understand this document Please read and understand this

More information

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance Page 1 of 165 Report No.: E309264-D1028-1/A0/C0-UL Test Report issued under the responsibility of: IEC 60601-1 Medical electrical equipment Part 1: General requirements for basic safety and essential performance

More information

Power Supply Display Module PSDM. Installation and Operation Manual

Power Supply Display Module PSDM. Installation and Operation Manual Power Supply Display Module PSDM Installation and Operation Manual Read this manual before using this product. Failure to follow the instructions and safety precautions in this manual can result in serious

More information

Commercial and Light Industrial Fire Alarm Control Panel

Commercial and Light Industrial Fire Alarm Control Panel FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel Features Easily expandable. All new plug-in board design Two supervised audible circuits Lamp and system trouble circuit test Ground

More information

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry LINETRAXX VMD420 Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry VMD420_D00137_02_D_XXEN/06.2016 LINETRAXX VMD420 Multi-functional

More information

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100 GETTING STARTED GUIDE NI 9217 4 RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100 This document explains how to connect to the NI 9217. Note Before you begin, complete the software and hardware installation

More information

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage LINETRAXX VME420 Multi-functional monitoring relay for undervoltage, overvoltage and frequency monitoring in AC/DC systems with separate supply voltage VME420_D00026_01_D_XXEN/06.2016 LINETRAXX VME420

More information

Flopurge TS. Operation Manual

Flopurge TS. Operation Manual Flopurge TS Operation Manual Part Number 079-0204 Spectron Gas Control Systems United Kingdom Unit 4, Herald Court, University of Warwick Science Park, Coventry, CV4 7EZ +44 (0)24 7641 6234 sales@spectron-gcs.com

More information

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate GETTING STARTED GUIDE NI 9213 16 TC, ±78 mv, 24 Bit, 75 S/s Aggregate This document explains how to connect to the NI 9213. Note Before you begin, complete the software and hardware installation procedures

More information

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description

More information

Basics of Safety Applications

Basics of Safety Applications Basics of Safety Applications Unrestricted Siemens 2016 usa.siemens.com/controls Why Safety Technology? Protection of People Environment Page 2 Safety Process Chain The necessary steps towards a safe machine

More information

UL HAZARDOUS LOCATIONS SERVICES

UL HAZARDOUS LOCATIONS SERVICES UL HAZARDOUS LOCATIONS SERVICES The international preference in hazardous locations certification for over 100 years ul.com/hazloc Explosive Gas Atmospheres Class I Division S Includes flammable gases,

More information

GETTING STARTED GUIDE NI DIO, 5 V/TTL, Bidirectional, 7 μs

GETTING STARTED GUIDE NI DIO, 5 V/TTL, Bidirectional, 7 μs GETTING STARTED GUIDE NI 9403 32 DIO, 5 V/TTL, Bidirectional, 7 μs This document explains how to connect to the NI 9403. Note Before you begin, complete the software and hardware installation procedures

More information

Snifter ATEX22 VERSION. User Manual. Distributor

Snifter ATEX22 VERSION. User Manual. Distributor Snifter ATEX22 VERSION User Manual Distributor Version 1.4 09/09/2009 Table of Contents 1. INTRODUCTION... 3 1.1. Safety... 3 1.2. Product overview... 4 1.3. How does it work?... 4 2. INSTALLATION... 5

More information

Basics of Safety Applications

Basics of Safety Applications Basics of Safety Applications Unrestricted Siemens 2016 usa.siemens.com/controls DISCLAIMER/ TERMS OF USE: THE INFORMATION PROVIDED HEREIN IS PROVIDED AS A GENERAL REFERENCE REGARDING THE USE OF THE APPLICABLE

More information

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH Page /3 SPECIFICATION SHEET Ed. Document UTE_ Issued Written Verified Approved MP36350 6-05-05 Strizzi Franco Page /3 INDICE HISTORY... 3 MODIFY RECORDING... 3 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

More information

Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac- Carriers Type Universal Engineering Guideline pac- Carriers Type 9195 Universal Integration of conventional process automation interfaces pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art

More information

Integrated Solutions Low Voltage Systems

Integrated Solutions Low Voltage Systems Integrated Solutions Low Voltage Systems 612 Contents Energy Distribution Overview Module Technology 8146 614 Overview Flameproof Enclosures 8220 614 Overview Flameproof Enclosures 8261 614 Overview CUBEx

More information

Ordering Key. Dielectric strength

Ordering Key. Dielectric strength Controllers AC Semiconductor Controller Type Soft starting and stopping of 3-phase squirrel cage motors Low inrush and reduced vibration during starting Integrated bypassing of semiconductors Rated operational

More information

FDC/ -B. Product information SYSTEM TECHNOLOGY FOR THE DOOR ECO

FDC/ -B. Product information SYSTEM TECHNOLOGY FOR THE DOOR ECO ECO FDC/ -B Product information SYSTEM TECHNOLOGY FOR THE DOOR FDC / -B Product characteristics FDC FDC- B Closing force Size acc. to EN (continuously adjustable) 3 6 4 6 Door width acc. to EN Dimensions

More information

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations: F1! 44487023 These instructions cover the following parts: PS902 Power Supply Installation Instructions! DANGER: To avoid risk of electric shock, turn off AC power before installing or servicing PS902

More information

GETTING STARTED GUIDE NI DI, 30 V, Sourcing, 7 μs

GETTING STARTED GUIDE NI DI, 30 V, Sourcing, 7 μs GETTING STARTED GUIDE NI 9426 32 DI, 30 V, Sourcing, 7 μs This document explains how to connect to the NI 9426. Note Before you begin, complete the software and hardware installation procedures in your

More information

Flameproof Manual Call Points

Flameproof Manual Call Points Operating instructions Additional languages www.r-stahl.com CS & Clifford & Snell Contents General Information.... Manufacturer.... Information regarding the operating instructions.... Further documents....

More information

Flameproof Manual Call Points Series MCP

Flameproof Manual Call Points Series MCP > Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied

More information

BC3250. Blowdown Controller

BC3250. Blowdown Controller Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

new new Industrial plugs and sockets

new new Industrial plugs and sockets Industrial plugs and sockets 213.1633 213.3236 221.1633 226.1636 New Optima series 16A-32A-63A-125A insulation voltage : 690V AC protection degree : IP44 and IP67 operating temperature : -25ºC to 40ºC

More information

GETTING STARTED GUIDE NI AI, ±29.4 mv/v, 24 Bit, 10 ks/s/ch Simultaneous, 350 Ω Quarter-Bridge Completion

GETTING STARTED GUIDE NI AI, ±29.4 mv/v, 24 Bit, 10 ks/s/ch Simultaneous, 350 Ω Quarter-Bridge Completion GETTING STARTED GUIDE NI 9236 8 AI, ±29.4 mv/v, 24 Bit, 10 ks/s/ch Simultaneous, 350 Ω Quarter-Bridge Completion This document explains how to connect to the NI 9236. Note Before you begin, complete the

More information

Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018

Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018 Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018 Before we start A Penny for Your Thoughts At the end of the session, share your feedback via

More information

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS ELECTROPROJECT POWER SUPPLY FOR DOOR MAGNETS Innovative and carefully thought out Always the right drive ELECTROPROJECT AANDRIJFTECHNIEK ElectroProject has evolved over the last 75 years from a technical

More information

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...:

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...: Test Report issued under the responsibility of: TEST REORT IEC 61008-1 Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) art 1: General

More information