FIRE ALARM Submittal DR. PECK FHM DAYTONA 4TH FL 125 MEMORIAL MEDICAL PARKWAY DAYTONA BEACH, FL 32117
|
|
- Jason Evans
- 6 years ago
- Views:
Transcription
1 SIEMEN FIRE ALARM Submittal Project Name: DR. PECK FHM DAYTONA 4TH FL 125 MEMORIAL MEDICAL PARKWAY DAYTONA BEACH, FL Project : DATE SUBMITTED: 11/10/14 WILE COPY SIEMENS Industry Inc. Building Technologies Division METRIC DRIVE SUITE 100 WINTER PARK, FLORIDA OFFICE: (407) FAX: (407)
2 X 3 3 SIEMENS INSTALLATION INSTRUCTIONS 2-WIRE FIELD SELECTABLE HORN, STROBE AND HORN/STROBE APPLIANCES (WALL AND CEILING MOUNT) IMPORTANT - All audible and visual signaling appliances must be installed in accordance with all applicable national and local fire alarm codes and any other required regulatory agencies. Series Z horn, strobe, and horn/strobe appliances are designed for easy installation. The ZH horn/strobes, ZH Horn and ZR strobes are for 24V operation. The appliance comes in two main parts. The universal mounting back plate allows the appliance to be mounted to a single-gang, double-gang, four square backbox, 4" octagon backbox, or a 3 J4" octagon backbox. Two wire appliance wiring is then connected to the mounting back plate. This allows a continuity check of the entire NAC circuit before any appliances are attached. It also allows the appliances to be installed after all finish work has been completed. The installer can snap or install the appliances when all other work is complete. Refer to P/N for the maximum number of appliances on a single notification appliance circuit. SPECIFICATIONS: -> Model" Voltage Range (Special Application) Per UL/ULC (VDCA/RMS) Table 1: Models and Settings Strobe (cd) Horn Current Draw See Table Mounting ZR-MC ZR-HMC /185 Wall ZR-MC-C /30/75/95 Ceiling ZR-HMC-C /177 3 Ceiling ZH-MC - ZH-HMC /185 X 4 Wall ZH-MC-C /30/75/95 X 4 Ceiling ZH-HMC-C I /177 X 4 Ceiling ZH Wall or Ceiling ** All models available in red and white. STROBE AND HORN STROBE APPLIANCES: Siemens' Series Strobe Appliances are UL Listed under Standard 1971 (Signaling Devices for the Hearing Impaired) for indoor Fire Protection Service and ULC Listed under Standard CAN/ULC-S for indoor Fire Protective Service. They are listed for indoor use only. Siemens' Series Horn Appliances provide a selectable Continuous or Code 3Horn tone when connected directly to an unsynchronized NAC (Notification Appliance Circuit). They can also provide a synchronized code 3 or march time horn tone when connected to a notification appliance circuit running the Siemens sync protocol The Horn Appliances can be field set for High (HI) or Low (LO) dba sound output. The Horn Appliances are UL Listed under Standard 464 for Audible Siqnal Appliances and ULC Listed under Standard CAN/ULC-S for Audible Signaling Devices for Fire Alarm Systems. They are listed for indoor use only. These models are designed for use with either filtered DC (VDC) or unfiltered Full-Wave-Rectified (VRMS) input voltage. All inputs are polarized for compatibility with standard reverse polarity supervision of circuit wiring by a FACP. The ZR Strobe, ZH Horn/Strobe, and ZH Horn are for 24V operation only. NOTE- The Code 3temporal pattern (1/2 second on, 1/2 second off, 1/2 second on, 1/2 second off, 1/2 second on, 1-1/2 off and repeat) is specified by ANSI and NFPA 72 for standard emergency evacuation signaling. The Code 3Horn should be used only for fire evacuation signaling and not for any other purpose. Description Continuous I lorn Code 3 Mom or * March Time Table 2A: ZH and ZH-MC dba Sound Output Reverberant dba per UL 464 Anechoic Per CANAJLC-S Volume Zl I and ZH-MC at 24 V Zl land ZH-MC at 24V 16.0V 24.0V 33.0V 16.0V 24.0V 33.0V High I,ow High Low "Available in sync mode only. 8 Fernwood Road 1'lorhamPark. New Jersey Siemens Building Technologies, Ltd Deny Road West Mississauga Ontario L5N 7A6 Canada
3 -3dBA -6dBA Table 2B: ULC Directional Characteristics 35 degrees left, 40 degrees right 55 degrees left, 65 degrees right CURRENT DRAW: Table 3: ZR Strobe Current Draw (Amps) at Volts Strobe Setting (cd) Voltage MC HMC MC-C HMC-C DC FWR I Voltage DC FWR Table 4: ZH Horn/Strobe Current Draw (Amps) at Volts Strobe Setting (cd) Horn MC HMC MC-C HMC-C Setting High* Low* High* Low* Current Draw is the same for the Continuous Horn, Code 3 Horn and March Time Settings. Table 5: ZH Horn Current Draw (Amps) Voltage Horn Setting Volts High* DC Low* High* FWR Low* * Cunent Draw is the same for the Continuous Horn, Code 3, and March Time Settings. NOTE: Candela and Horn Setting will determine the current draw of the product. When calculating the total cunents use Tables 3-5 to determine the highest value of RMS current for an individual appliance, then multiply these values by the total number of appliances. Be sure to add the currents for any other appliances, including audible signaling appliances powered by the same source, and to include any required safety factors. NOTE: These notification appliances are UL Listed as "Special Application". They are intended to be used only with Siemens notification appliance circuits. NOTE- THESE APPLIANCES WERE TESTED TO THE OPERATING VOLTAGE RANGE LIMITS OF VOLTS FOR 24V MODELS USING FILTERED DC OR UNFILTERED FULL-WAVE-RECTIFIED VOLTAGE. DO NOT APPLY VOLTAGE OUTSIDE OF THIS RANGE. NOTE- REFER TO THE INSTALLATION INSTRUCTIONS FOR THE APPROPRIATE NAC TO FIND THE MAXIMUM ALLOWED VOLTAGE DROP. USE THIS VALUE ALONG WITH THE CURRENT DRAW FOR THE APPLIANCE TO DETERMINE THE ALLOWABLE WIRE RESISTANCE. THE MAXIMUM WIRE RESISTANCE BETWEEN STROBES SHALL NOT EXCEED 35 OHMS. NOTE: Strobes arenot designed tobeused on coded systems in which the applied voltage iscycled onand off. NOTE- MAKE SURE THAT THE TOTAL RMS CURRENT REQUIRED BY ALL APPLIANCES THAT ARE CONNECTED TO THE SYSTEM'S PRIMARY AND SECONDARY POWER SOURCES DO NOT EXCEED THE POWER SOURCES' RATED CAPACITY OR THE CURRENT RATINGS OF ANY FUSES ON THE CIRCUITS TO WHICH THESE APPLIANCES ARE WIRED. OVERLOADING POWER SOURCES OR EXCEEDING FUSE RATINGS COULD RESULT IN LOSS OF POWER AND FAILURE TO ALERT OCCUPANTS DURING AN EMERGENCY, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TOYOU AND/OR OTHERS. WIRING AND MOUNTING BASE: FROM PRECEDING APPLIANCE OR FACP TO NEXT APPLIANCE OR END OF LINE RESISTOR (EOLR) All strobe appliances have in-outwiring terminals that accept two#12 to #18 American Wire Gauge (AWG) wires at each screw terminal. Strip leads 3/8 inches and connect to screw terminals. Break ail in-out wire runs on supervised circuits to ensure integrity of circuit supervision as shownin Figure 2. The polarity shown inthe wiring diagramsis forthe operation of the appliances. The polarity is reversed by the FACP during supervision. Figure 1: Figure 2: P E Sheet 2 of4
4 WIRING AND MOUNTING SETTINGS: Note: The ZH is factory set for the most common application of High db and Code 3. HORN SELECTION Jumper Plug and Candela Selectors _zx T7- ANDELA SELECTION CANDELA POINTER pandela SELECTION CANDELA POINTER HMC-C CANDELA POINTER MC-C CANDELA POINTER MC CANDELA POINTER HMC CANDELA POINTER Note: Candela Factory Settings are shown in above illustration. Jumper plug settings for High db and Code 3 (or March Time). Jumper plug settings for Low db and Code 3 (or March Time). nn i M UillLf N. i 11 t Uii il u u u u NO PLUG HORN LOW NO PLUG HORN LOW WITH PLUG C0DE3 HI ;V;TH PLUG C00E3 H Jumper plug settings for High db and Continuous Horn. Jumper plug settings for Low db and Continuous Horn.! I D NO PLUG HORN LOW NO PLUG HORN LOW H PLUG C0DE3i H. WITH PLUG C0DE3 P I E Sheet 3 of4
5 NOTE: Use needle nose pliers topull and properly setthe jumper plugs. No jumper plugs are needed for Continuous Horn and low db settings. However, itis recommended that the jumper plug be retained in the unitfor future use (ifneeded) as shown. CAUTION: Check thatthe installed product will havesufficient clearance and wiring room prior to installing backboxes and conduit, especially ifsheathed multiconductor cable or 3/4" conduit fittings are used. CAUTION: DO NOTOVER TIGHTEN MOUNTING SCREWS. EXCESSIVETORQUE CAN DISTORTTHE BASE ANDMAY AFFECT OPERATION. MOUNTING OPTIONS: OPTIONAL SECURING SCREWS SIDE OPENING FOR FLAT SCREWDRIVER Figure 3: Installation Figure 4: Removal (See step 8 below) 1. Install mounting plate as shown in figure 1 to a single-gang, double-gang, 4" square, 4" octagon, or a 3!4" octagon backbox with the provided pan head screws. To remove dust cover, place thumb and index finger on top edoes of cover and pull off cover. 2. Connect field wiring per figures 2 and Address wires back into backbox. 4. Place dust cover over mounting plate to protect the terminals while performing wiring continuity check.. 5. Remove dust cover before snapping or installing the appliance onto the mounting plate per fig 3. Important: Device only has one mounting orientation. Match the top of the base to the top of the device. If it is desired to further secure the device to the base, then two optional screws are provided. To install these screws punch out the screw holes located at the top and bottom of the device. To remove the appliance, push a small flat-bladed screwdriver into the side opening. The screwdriver must clear the snap release opening by V* to disengage the snap. Do not pry off housing with the screw driver. Apply pressure with screw driver, inserted in either side opening, as shown in Fig 4 to release the housing. NOTE: NFPA 72/ANS conform to ADAAG Equivalent Facilitation Guidelines in using fewer, higher intensity strobes within the same protected area. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limitsare designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to conect the interference by one or more of the following measures: 1) Reorient or relocate the receiving antenna, 2) Increase the separation between the equipment and receiver, 3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected, and 4) Consult the dealer or an experienced radio/tv technician for help. P E Sheet 4 of 4
6 SIEMENS INSTALLATION INSTRUCTIONS MULTI-CANDELA ELECTRONIC CHIME STROBE IMPORTANT: All audible and visual signaling appliances must be installed in accordance with all applicable national and local fire alarm codes and any other required regulatory agencies. Series CH-MC Multi-Candela Electronic Chime Strobe is UL Listed under Standard 1971 for Signaling Devices for the Hearing Impaired and UL Standard for Private Mode Audible Signal Appliances. The CH-MC Chime Strobe is designed for low current draw and versatile performance. This model offers a choice of single stroke or vibrating operation, has adjustable sound level, and has a chime tone adjustable from 800 to 1200Hz. The CH-MC Multi-Candela strobe provides four selectable light output intensities in one unit. This appliance also incorporates a chime mounting plate attached to the chime for ease of installation. The Chime Strobe model can provide a non-synchronized strobe appliance when connected directly to a fire alarm control panel (FACP), or provide a synchronized strobe appliance when connected to a notification appliance circuit running the Siemens sync protocol. The strobe uses a xenon flashtube with solid state circuitry enclosed in a polycarbonate lens to provide maximum visibility and reliability for effective visible signaling. The CH-MC is Listed for indoor use, wall mount only with the backboxes specified in these instructions (see wiring and mounting information). The CH-MC model is UL Listed for indoor use with a temperature range of +32 F to +120=F (0 C to +49 C) and maximum humidity of 85% RH. The effect of shipping and storage temperatures shall not adversely affect the performance of the appliance when it is stored in the original cartons and is not subjected to misuse or abuse. NFPA 72/ANSI conform to ADAAG Equivalent Facilitation Guidelines in using fewer, higher intensity strobes within the same protected area. Refer to P/N for the maximum number of appliances on a single notification appliance circuit. SPECIFICATIONS: -> Models* Operating Voltage (Special Application) Per UL 1971 (VDCA/RMS) Table 1: UL Listed Models and Ratings Maximum RMS Current (Chime Only) dba at 10 Feet Reverberant Max Min Max Candela Mounting CH-MC /30/75/110 A,B 'Available in red and white. NOTES: 1. The strobe will produce 1 flash per second over the Input Voltage range. 2. The strobes meet the required light distribution patterns defined in UL The chime must be set at maximum volume for Private Mode Fire Protective Service per UL 464 listing requirements (see page 3). 4. The chime produces a brief inrush current of Amps with filtered DC input (0.140 Amps with full-wave-rectified (VRMS) input) with a time duration of 100 milliseconds.! WARNING: CANDELA SETTING WILL DETERMINE THE CURRENT DRAW OF THE PRODUCT. Table 2: UL Current Ratings (Strobe Only) Maximum RMS Current (Amps) UL Voltage 15cd 30cd 75cd 110cd DC 16-33VDC FWR 16-33VRMS When calculating the total currents use Table 2 to determine the highest value of RMS current for an individual strobe, then multiply these values by the total number of strobes. Be sure to add the currents for any other appliances, including audible signaling appliances powered by the same source, and to include any required safety factors. Options Note: These notification appliances are UL Listed as "Special Application". circuits. They are intended to be used only with Siemens notification appliance These appliances were tested to the voltage limits of volts for 24V models using filtered DC or unfiltered Full-Wave-Rectified Voltage. apply voltage outside of this range. Do not Note: Refer to the installation instructions for the appropriate NAC to find the maximum allowed voltage drop. Use this value along with the current draw for the appliance to determine the allowable wire resistance. The maximum wire resistance between strobes shall not exceed 35 ohms.! CAUTION: Strobes are not designed to be usedoncoded systems in which the applied voltage is cycled onandoff.! WARNING: MAKE SURE THAT THE TOTAL RMS CURRENT REQUIRED BYALL APPLIANCES THAT ARE CONNECTED TO THE SYSTEM'S PRIMARY AND SECONDARY POWER SOURCES DO NOT EXCEED THE POWER SOURCES' RATED CAPACITY OR THE CURRENT RATINGS OF ANY FUSES ON THE CIRCUITS TO WHICH THESE APPLIANCES ARE WIRED. OVERLOADING POWER SOURCES OR EXCEEDING FUSE RATINGS COULD RESULT IN LOSS OF POWER AND FAILURE TO ALERT OCCUPANTS DURING AN EMERGENCY, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. 8 Fernwood Road Florham Park, New Jersey P B Sheet l of 3
7 WIRING AND MOUNTING INFORMATION: The following figures (A,B) show the maximum number of field wires (conductors) that can enter the backbox used with each mounting option. If these limits are exceeded, there may be insufficient space in the backbox to accommodate the field wires and stresses from the wires could damaqe the product. Check that the installed product will have sufficient clearance and wiring room prior to installing backboxes and conduit, especially if sheathed multicondudor cable or 3/4" conduit fittingsare used. FLUSH MOUNTING (STROBE SPEAKER) SURFACE MOUNTING (STROBE SPEAKER) SURFACE ;/" DACKBOX -^ (SBBS) Vs "", r SPEAKER MOUNTING PLATE SQUARE OR ROUND GRILLE SPEAKER MOUNTING PLATE MAXIMUM NUMBER QF CQNPUCIORS AWG81B AWG0I6 AWOffM AWOQ1? NOTE BACKK3XISCCMMT1BLEVUIHVVIREMCILDANOCONOU1T MOUNTING HOLES ARE TOR SINGLE-GANG. OOUOCE-OANO «' SQ 3-1W & r OCTAGON OR ROUND BACKBOXES MAXIMUM NUMBER OF CONDUCTORS ftwgffib AWOW1B AWttOM AWGW1? Figure 1: Chime Appliance and Strobe Appliance operate independently. Recommended for coded systems where the chime is set on single stroke (SS) mode and is cycled on and offwhile the strobe flashes continuously. Figure 2: Chime Appliance and Strobe Appliance operate in unison. Red and black wires are supplied. The chime must be set for vibrating mode (VIB). (Use of Sync Protocol is not recommended in this wiring option) FROM PRECEDING CHIME OR FIRE ALARM + CONTROL PANEL (FACP)- FROM PRECEDING + STROBE OR FACP I I [HfcaJi I STROBE CHIME TO NEXT CHIME OR END-OF-LINE RESISTOR (EOLR) TO NEXT STROBE OR EOLR FROM PRECEDING APPLIANCE OR FIRE ALARM CONTROL PANEL (FACP) STROBE CHIME TO NEXT APPLIANCE OR END OF LINE RESISTOR (EOLR) Figure 3: El I The Chime Strobe model has in-out wiring terminals that accept two #12 to #18 American Wire Gauge (AWG) wires at each screw terminal. Strip leads 3/8 inches and connect to screw terminals. Break all in-out wire runs on supervised circuits to assure integrityof circuit supervision as shown in Figure 3. The polarity shown in the wiring diagrams is for operation of the appliances. The polarity is reversed by the FACP during supervision. GROUNDING: Install the appliance to a grounded backbox (Per NFPA 70, the National Electrical Code) using the lockwashers provided in hardware bag under the head of each mounting screw for the appliance. Figure 4: PC Board Layout 1. The chime is factory set in single stroke (SS) mode. It can be changed to vibrating (VIB) mode before wiring the appliance with the provided jumper. Refer to PC Board layout shown in Figure 4. (SS = single stroke, VIB = vibrating) SINGLE STROKE OPERATION: The minimum input pulse duration must be at least 160 milliseconds "on" time and 160 milliseconds "off' time. The chime will only operate once each time it is pulsed. This mode is recommended for coded systems. VIBRATING OPERATION: Continuous input voltage must be applied to the chime to activate the chime at one second intervals. i i 2. The volume and tone controls have been adjusted at the factory to insure maximum dba output. However, once the mode is selected, the installer may want to fine tune the appliance to better suit the application. P B Sheet 2 of 3
8 Figure 5: /^ k,,jx, r^"n 1 rl TsA^lol M \ INSERT \ DRIVER \ H 1 U NOTE: The CH-MCcomes pre-set at 15cd. X WARNING: THE CANDELA SELECT SWITCH MUST BE FIELD SET TO THE REQUIRED CANDELA INTENSITY BEFORE INSTALLATION WHEN CHANGING THE SETTING OF THE CANDELA SELECT SWITCH, MAKE CERTAIN THAT IT "CLICKS" IN PLACE. AFTER CHANGING THE CANDELA SETTING, THE APPLIANCE MUST BE RETESTED TO VERIFY PROPER OPERATION. MOUNTING PROCEDURES: 1. This model can be flush mounted to a 4" square by 2-1/8" deep backbox with a 4" square 1-1/2" extension ring (Figure A), surface mounted toa Surface Backbox (Figure B). Mounting hardware foreach mounting option is supplied. 2. Conduit entrances to the backbox should be selected to provide sufficient wiring clearance for the installed product. Do not pass additional wires (used for other than the signaling appliance) through the backbox. Such additional wires could result in insufficient wiring space for the signaling appliance. 3. When terminating field wires, do not use more lead length than required. Excess lead length could result in insufficient wiring space for the signaling appliance. 4. Use care and proper techniques to position the field wires in the backbox so that they use minimum space and produce minimum stress on the product. This isespecially important for stiff, heavy gaugewires andwires with thick insulation orsheathing. 5. This model hasan integrated mounting plate which must beoriented correctly when it is mounted tothe backbox. Turn the mounting plate so that the arrow above the words"horizontal Strobe" or "Top" pointsto the top side ofthe mounting plate 6. To move selectorswitch, insertscrewdriver into slotshown on the bottom side ofthe strobe. See Figure Mount the chime mounting plateto the backbox with the cone protector on. After the chime mounting plateis attached to the backbox, remove the cone protector before installing the grille. Next, attachthe grille to the chime mounting plateand attachwith (2)screws. The 110 Candela Strobe setting is Listed for use insleeping or non-sleeping areas when installed in accordance with appropriate NFPA Standards and the Authority Having Jurisdiction. _L WARNING: INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS SHOULD BE WALL MOUNTED AT LEAST 24" BELOW THE CEILING AS FOLLOWS: (1) THE ON-AXIS (DIRECTLY IN FRONT OF LENS) LIGHT OUTPUT SHOULD BE DIRECTED AT THE EYELIDS OF THE SLEEPING PERSON, E.G. PILLOW END OF BED, BED HEAD; (2) NO PART OF THE BED SHALL BE MORE THAN SIXTEEN (16) FEET FROM THE STROBE NOTIFICATION APPLIANCE. INSTALLERS MUST ADVISE OWNERS AND OPERATORS OF BUILDINGS WITH SLEEPING OCCUPANTS, E.G. HOTELS AND MOTELS, TO WARN GUESTS, RESIDENTS AND EMPLOYEES TO NOT MOVE THE BED LOCATION TO A POSITION VIOLATING POINTS (1) AND (2) ABOVE OR SERIOUS INJURY AND/OR LOSS OF LIFE MAY OCCUR DURING A FIRE EMERGENCY. X WARNING: ASMALL POSSIBILITY EXISTS THAT THE USE OF MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW, UNDER CERTAIN CIRCUMSTANCES, MIGHT INDUCE A PHOTO-SENSITIVE RESPONSE IN PERSONS WITH EPILEPSY. STROBE REFLECTIONS IN A GLASS OR MIRRORED SURFACE MIGHT ALSO INDUCE SUCH A RESPONSE. TO MINIMIZE THIS POSSIBLE HAZARD, SIEMENS BUILDING TECHNOLOGIES STRONGLY RECOMMENDS THAT THE STROBES INSTALLED SHOULD NOT PRESENT A COMPOSITE FLASH RATE IN THE FIELD OF VIEW WHICH EXCEEDS FIVE (S) Hz AT THE OPERATING VOLTAGE OF THE STROBES. SIEMENS BUILDING TECHNOLOGIES ALSO STRONGLY RECOMMENDS THAT THE INTENSITY AND COMPOSITE FLASH RATE OF INSTALLED STROBES COMPLY WITH LEVELS ESTABLISHED BY APPLICABLE LAWS, STANDARDS, REGULATIONS, CODES AND GUIDELINES. NOTE: This equipment has been tested and found to comply with the limitsfor a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipmentoffand on, the user is encouraged to try to correct the interference by one or more of the following measures: 1) Reorient or relocate the receiving antenna, 2) Increase the separation between the equipment and receiver, 3) Connect the equipment into an outlet on a circuit differentfrom that to which the receiver is connected, and 4) Consult the dealer or an experienced radio/tv technician for help. P B Sheet 3 of3
9 SIEMENS Data Sheet Fire Safety &Security Products FACP Accessories PAD-4 Distributed Power Supply Unit Notification Appliance Circuit Extender Models PAD-4-ENCL, PAD-4-MB (with FP2011-U1, FP2012-U1 power supplies) ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) 'Class B'# power-limited notification appliance circuits (NACs), field-selectable wiring Each unit can support an optional module (Model PAD-4-CLSA) that converts two (2) built-in NACs into four (4) NACs Up to 3 Amps of auxiliary-power output Optional built-in strobe synchronization Supports coded audible signals, includingtemporal 3, Temporal 4 patterns Battery supervision and control 'Form C general Trouble I AC Failmonitoring contact Power supplies support NAC power Up to 6A used with Model FP2011-U1 - Up to 9A used with Model FP2012-U1 24VDC output voltage Ground-fault detection Advanced microprocessor control Uses Flash memory-based system firmware Optional system-diagnostic and firmware-upgrade tool Product Overview Used with Siemens - Fire Safety fire alarm control panels (FACPs), the Distributed Power Supply PAD-4 Unit is a NAC expander with a built-in, auxiliarypower output. Each PAD-4 unit distributes additional power in buildings for audible and visual indicators that conform to the Americans with Disabilities Act (ADA). PAD-4 also has the following features: NACs Signal-input circuits Battery-charging circuit Trouble relays for remote monitoring Diagnostic light-emitting diodes (LEDs) Alternating Current (AC) power connection The Siemens NACs, which connect with alarm signaling devices, have been designed to provide the highest level of reliability and performance. Signal coding on the circuits is accomplished through integrated circuits (rather than relays), which eliminates mechanical wear on the output circuits. r*!v {Vl HI j.; Adapter Card [Model PAD-4-CLSA] Main Board (Model PAD-4-MB] Unit Enclosure [Model PAD-4-ENCL] Multi-module mounting in System 3 enclosures Multiple modules share battery set ADA Compliant UL864 9th Edition Listed; UL 1481 Listed (for power supplies) The PAD-4 unit provides consistent 24VDC output voltage to each NAC - independent of voltage fluctuations on the primary or secondary power source. As a result, a larger voltage drop and a greater wire length for each NAC are supported by each PAD-4. Specifications This version of the Siemens Distributed Power Supply Unit can be configured in the following manner that makes the outputs easily programmable: 'STEADY'outputs Synchronized strobe outputs American National Standards Institute (ANSI) Temporal 3 ANSI Temporal4 [for carbon monoxide (CO) alarm signal] There are also two (2) inputs used to control the activation of the four (4) outputs. Programming can be set so one (1) input will silence the audible signal on Siemens Models 'AS'-series, 'NS'-series, or'zh'- series horn and horn-strobes while the strobes remain active. SIEMENS Industry, Inc. Building Technologies Division Distributed Power Supply - NAC Extender (Model PAD-4 series) 3363
10 Specifications (continued) Operation of each PAD-4 unit is controlled by firmware stored in Flash memory on the main board, as well as the storage of a 10-event log, which can be viewed via Model PAD-4-FDT. In the event that an upgrade to the system firmware is required, the firmware can be transferred to the system without the replacement of firmware chips. An optional firmware-download software tool, Model PAD-4-FDT, can be used for system diagnostic testing of the following: Primary-power voltage readouts Current draw for power charger Configuration switch settings Firmware version Battery voltage When the tool is in communication with Model PAD- 4-MB, the Test Mode' LED is illuminated. Model PAD-4-LUA is a USB serial port adapter that is required for tool-kit operation. Each NAC extender supervises a variety of functions including: Low AC power Battery-voltage level Earth ground-fault conditions All power can be directed to two (2) or four (4) 'Class B' power-limited NACs. Each NAC supports up to 3 Amps per circuit. Either one (1) or two (2) inputs can control four (4) outputs, which are compatible with all Siemens - Fire Safety 24VDC alarm signaling devices. In cases where circuits are used, an optional Model PAD-4-CLSA module can be added, providing two (2) additional outputs to each PAD-4 unit. Each NAC extender is also capable of operating other parts of a Siemens fire alarm system, such as door holders, via 3 24VDC max of power-limited auxiliary output. When the output activated, the total power available cannot exceed 6 Amps when used with Models FP2011-U1 or 9 Amps when used withfp2012-u1. Trouble conditions are monitored through each unit's two (2) inputs. In addition, one (1) 'Form C Trouble contact is provided for monitoring each unit that is connected through the input of a Siemens FACP. Therefore, the user has the option of connecting a PAD-4 NAC extender unit into a NAC of a Siemens FACP, or the unit may be monitored with a Model TRI-series monitoring module on a Siemens intelligent fire system. Aseparate 'Form C Trouble contact is used exclusively with each NAC extender to indicate AC Fail Trouble events on the NAC extender. Each unit is packaged in its own sheet-metal enclosure with sufficient space to house up to 7AH battery sets. The enclosure (Model PAD-4-ENCL) is available in red. The battery charger used in each unit can energize batteries of up to 18AH. Though, when battery sets greater than 7AH are required, the battery set must be housed in a System 3 enclosure or a separate UL Listed battery enclosure. System 3 enclosures may also be used to house multiple Model PAD-4 units in a single enclosure, via the Model S3AP Adapter Plate. Two (2) units are capable of sharing the same battery set when mounted in the same enclosure. Model S3AP can also be used to mount the PAD-4 main board and 170-Watt power supply (Model FP2011-U1) into a PAD-3 enclosure. Each Model PAD-4-series unit complies with seismic certification, pursuant to ASC / SEi 7-05, Section , when used with the PAD-4 battery bracket (Model PAD4-BATT-BRKT). Configuration Options Option Input[s] Output Controls Circuit Types 1 All outputs 'Class B'circuits Input 2* Input 2 Input 2 All outputs Silences horns on Output 1 Outputs 1 and 2 Outputs 3 and 4 Output 1 Outputs 2, 3 and 4 5 Outputs 1 through Input 2* Input 2 Input 2 Outputs 1 through 4 Silences horns on Output 1 Outputs 1 and 2 Outputs 3 and 4 Outputs 1 and 2 Outputs 3 and 4 'Class B' circuits 'Class B'circuits 'Class B'circuits 'Class B'circuits 'Class B'circuits circuit pairs circuit pairs circuit pairs circuit pairs circuit pairs 'Class B'circuits denotes when used with Siemens Model 'AS','NS'or "ZH' series horn I strobe devices SIEMENS Industry, Inc. Building Technologies Division
11 Indicator Lights AC Power ON: Green ) AUX/PS: Ground Fault: Output 1 Trouble: Output 2 Trouble: Output 3 Trouble: Output 4 Trouble: Temperature and Humidity Range Each PAD-4 Distributed Power Supply Unit is UL 864 9th Edition Listed for indoor dry locations within a temperature range of 120+/-3 F (49+/-2 C) to 32+/-3 F (0+/-2 C) and a relative humidity of 93+/-2% at a temperature of 90+/-3 F (32-i-/-2nC). Details for Ordering Test Mode: Model Part Description PAD-4-ENCL PAD-unit enclosure Technical Data AC Fail Trouble Contact Rating: {'Form A' - Normally Closed (N.C) } Basic Trouble Contact Rating: { 'Form C } Alarm Current: { for NACs and auxiliary power } Ambient Temperature: Relative Humidity: Auxiliary Power Circuit: Battery Charging Capacity: Input Circuits/ Configurations: Input Current: Input Voltage Range: Installation Environment: NACs: Total Output Power: Output Circuits / Configurations: Single-Unit Dimensions: { W -x- H -x- D } Model PAD-4-ENCL Color: Model PAD-4-ENCL 30VDC, max. [resistive] 30VDC, max. [resistive] 3.0A per circuit, max. 6A, max. (via Model FP2011-U1) 9A, max. (via Model FP2012-U1} F (0-49 C) Up to 86 F (30 C); non-condensinq One (1) 3A max. 18AH Two (2) 'Class B'supervised or Two (2) supervised 7.0mA, max VDC/VI-W Indoor, dry c Supervised, power-limited c 1.0mA standby current, max. o Four (4) circuits z 2K ohms (-r). 8K ohms (-) 24VDC@6Amps (with Model FP2011-U1); 9 Amps (with Model FP2012-U1) o Two (2) ; - Up to four (4) (via Model PAD-4-CLSA}. o Four (4) 'Class B'; o One (1) Class A, Two (2) Class B; 13.5"-x-18.75"-x-3.25" (34.3 cm. -x cm. -x- 8.3 cm.) Red PAD-4-MB PAD-unit main board FP2011-U Watt power supply FP2012-U1 S54400-Z60-A1 300-Watt power supply Model PAD4-6A PAD4-6A-CtSA PAD4-9A PAD4-9A-CtSA Model System Kits Part S54339-A1-A1 S54339-A2-A1 S54339-A3-A1 S54339-A4-A1 Description Complete 6A PAD-4 kit with: - One (1) Unit Enclosure. PAD-4-ENCL - One (1) Main Board, PAD-4-M8 - One (1) 170W power supply. FP2011-U1 Complete 6A PAD-4 kit with: - One (1) Unit Enclosure, PAD-4-ENCL - One (1) Main Board. PAD-4-MB - One(1) 170W power supply, FP2011-U1 - One (1) Adapter Card, PAD-4-CLSA Complete 9A PAD-4 kit with: - One (1) Unit Enclosure, PAD-4-ENCL - One (1) Main Board. PAD-4-MB - One (1) 300W power supply, FP2012-U1 Complete 9A PAD-4 kit with: - One (1) Unit Enclosure. PAD-4-ENCL - One (1) Main Board, PAD-4-MB - One(1) 300W power supply, FP2012-U1 - One (1) Adapter Card, PAD-4-CLSA Optional Accessories Part Description PAD4-BATT-BRKT S54430-B4-A1 Battery bracket for NACexpander PAD-4-LU A S54389-C1-A1 PAD-4 Laptop-Upload Adapter PAD-4-CLSA Adapter Card S3AP PAD-4 NACexpander adapter plate (for use with PAD-3 and System 3 enclosures) SIEMENS Industry, Inc. Building Technologies Division
Use this product according to this instruction manual. Please keep this instruction manual for future reference.
273 Branchport Avenue Thank you for using our products. Long Branch, NJ 07740 (800) 631-2148 INSTALLATION INSTRUCTIONS www.cooperwheelock.com E50 MULTI-CANDELA SPEAKER STROBES GENERAL: Use this product
More information1 Watt Supervised Self-Amplified Strobe Speakers Round Flush Grille with 75cd Strobe
273 Branchport Avenue Long Branch, N.J. 07740 (800) 631-2148 Thank you for using our products. www.wheelockinc.com INSTALLATION INSTRUCTIONS SUPERVISED SELF-AMPLIFIED STROBE SPEAKERS Use this product according
More informations Notification Appliances
s Notification Appliances Data Sheet Fire Safety Products AS & AH Audible Horn Strobe / Audible Horn Appliances Application: Indoor / Outdoor AS-MC-CW AS-MC-R AH-R AH-W Product Overview Fast installation
More informationTable 1: dba Ratings for AMT Multitone Signal Typical Anechoic dba at 10 Feet per CAN/ULC S525-07
273 Branchport Avenue Long Branch, NJ 07740 (800) 631-2148 (USA) Thank you for using our products. (800) 397-5777 (CANADA) www.coopernotification.com GENERAL: INSTALLATION INSTRUCTIONS AMT MULTITONE APPLIANCES
More information08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor
s Data Sheet Fire Safety & Security Products 08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor AS-MC-CW AS-MC-R AH-W AH-R Product Overview
More information*15cd models are Listed at 15cd and meet 75cd on axis
273 Branchport Avenue Long Branch, NJ 07740 Thank you for using our products. (800) 631-2148 INSTALLATION INSTRUCTIONS www.wheelockinc.com MULTITONE STROBE APPLIANCES Use this product according to this
More informationSELECT-A-HORN/STROBE SERIES
SELECT-A-HORN/STROBE SERIES Features Description Mircom s Select-A-Strobe/Horn Series is designed to comply with the Americans with Disability Act (ADA) and meet UL standard 1971 requirements for emergency
More information'08 Series Notification A liances
SIEMENS Data Sheet Fire Safety & Security Products '08 Series Notification A liances AS I AH & AS - Audible Strobe Appliances and AH Audibles AS-MC-CW AS-MC-R AH-W AH-R Product Overview - Fast installation
More informationWheelock RSS & RSSP Series
Wheelock RSS & RSSP Series Single- and Multi-Candela Strobes and Strobe Plates DF-51780:A G-520 General Wheelock s patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current
More informationGenesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet
Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet Table 1: Models Description Low frequency (520 Hz) horn, white housing, no FIRE marking, standard output clear strobe light Low frequency (520
More information11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies
11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies Visible Signals Agenda 1. Physics 2. Installation Considerations
More informationGenesis LED G1 Series
EDWARDS Catalog u Strobes, Horns, Bells, Chimes LIFE SAFETY INCIDENT MANAGEMENT Genesis LED G1 Series Compact Notification Devices S218, S5389 7125-1657:0506 7135-1657:0502 Overview Genesis LED G1 Series
More informationSC-6 Six Supervised Control Module
INSTALLATION AND MAINTENANCE INSTRUCTIONS SC-6 Six Supervised Control Module SPECIFICATIONS Normal Operating Voltage: Stand-By Current: Alarm Current: Temperature Range: Humidity: Dimensions: Accessories:
More informationL-Series, Emergency Communication Devices
Notification Appliances L-Series, Emergency Communication Devices Description The L-Series Emergency Communications devices and accessories combine application versatility with all of the same time-saving
More informationTrueAlert Addressable Notification Appliances
UL, ULC Listed* TrueAlert Addressable Notification Appliances Audible/Visible Notification Appliances; Multi-Tone Horn/Strobe with 520 Hz Output Features Individually addressed and controlled multi-tone
More informationECC-50/100C. Emergency Command Center
ECC-50/100C Emergency Command Center Canadian DF-60815:B Emergency Communications General Fire-lite s ECC-50/100C is a multipurpose emergency voice evacuation panel for fire applications, mass notification
More informationPotter Wall Mount Select-A-Strobe
104 Kenran Industrial Dr. Potter Wall Mount Select-A-Strobe SL-1224 SERIES SELECT-A-STROBE Call for additional listings 12 VDC with 15, 35 or 60 cd setting 24 VDC with 15, 35, 60, 5, 95 or 110 6 distinct
More informationTrueAlert Multi-Candela Notification Appliances
TrueAlert Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved* Features 24 VDC high intensity notification appliance common features: Xenon strobe with intensity selectable as 135,
More informationBooster Power Supply Manual
Supply Manual DEVELOPED BY COPYRIGHT NOTICE General Signal Building Systems Corporation 6411 Parkland Drive Sarasota, FL 34243 (941) 739-4300 Copyright 1999 General Signal Building Systems Corporation
More informationTrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions
TrueAlert NonAddressable, MultiCandela Notification Appliances Installation Instructions PRODUCT IDENTIFICATION REFERENCE (See Page 4 for Detailed Product Specifications) Type Mount Model Color Operation
More informationField Configurable Horns and Strobes
EDWARDS Catalog u Strobes, Horns, Bells, Chimes LIFE SAFETY & INCIDENT MANAGEMENT Field Configurable Horns and Strobes Genesis Series ECS/MNS appliances available with clear or amber lenses. S218, S5389,
More informationCautions and Warnings. Introduction 4009 NAC POWER EXTENDER
Cautions and Warnings DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED. Upon unpacking your Simplex product, inspect the contents of the carton for shipping damage. If damage is apparent, immediately
More informationData Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906
s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones
More informationModel PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual
Fire Safety Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual Siemens Building Technologies, Inc. Siemens Building Technologies, Ltd. 8 Fernwood Road 2 Kenview
More informationInstallation Instructions Model ABHW-4S
Installation Instructions Model ABHW-4S Intelligent Audible Base for Sleeping Area with 520Hz Low Frequency Sounder Introduction Application note The Model ABHW-4S audible base from Siemens Industry, Inc.
More informationL-Series, Indoor Strobes and Horn Strobes
Notification Appliances L-Series, Indoor Strobes and Horn Strobes Indoor Selectable-Output Strobes/Horn Strobes for Ceiling Applications General The L-Series audible visible notification products offer
More informationLifeAlarm Fire Alarm Controls
UL, ULC Approved* LifeAlarm Fire Alarm Controls 4009 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs Features Provides additional notification appliance circuit (NAC) capacity
More informationTrueAlert Notification Appliances
TrueAlert Notification Appliances UL Listed; FM, CSFM and MEA (NYC) Approved* Non-Addressable Audible/Visible Notification Appliances with SmartSync Operation of Strobes and Horns Features Wall mount audible/visible
More informationField Configurable Horns and Strobes
Vigilant Catalog Strobes, Horns, Bells, Chimes Field Configurable Horns and Strobes Genesis Series MNEC appliances available with clear or amber lenses. Pending Overview The Genesis line of fire alarm
More informationGENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING
GENERAL The VEC 25/50 is a state-of-the-art, compact, stand-alone or slave Emergency Voice Evacuation Control. The VEC 25/50 is offered in a self-contained, cost-effective design and includes a 25 Watt,
More informationCSH24CH. Colored Light Strobe/Horn Series High Candela. Description. Features. Ceiling/Wall Mount Patent Pending. Ordering Information
OF FIRE CS24C Colored Light Strobe/orn Series igh Candela Ceiling/Wall Mount Patent Pending Description AMSECO's UL listed Colored Light Strobe CS24C series is designed to provide audible and visual signals
More informationSECTION FIRE ALARM SYSTEMS
SECTION 16721 FIRE ALARM SYSTEMS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work
More informationSIGA-CC1 Single Input Signal Module Installation Sheet
SIGA-CC1 Single Input Signal Module Installation Sheet Personality codes Use the personality codes described below to configure the SIGA-CC1 module. See Table 1 for listing information Table 1: Personality
More informationECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS
ECC-50/100(E) Emergency Command Center DF-60734:A4 General Firelite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,
More informationPrint Specification. Publication. Instructions. Specific requirements. General requirements
Print Specification Publication GSA-CC1 Single Input Signal Module Installation Sheet P/N P-047550-1802-EN REV 04 ISS 23JUN15 Instructions This page is the print specification for the publication. It is
More information1. POWERPATH Operation
273 Branchport Avenue Long Branch, NJ 07740 (800) 631-2148 www.wheelockinc.com Thank you for using our products. INSTALLATION INSTRUCTIONS MODEL PS-12/24-6 POWERPATH Use this product according to this
More informationJuly 14, 1999 DF C-100.
www.firelite.com GENERAL The Fire Lite FIRE COMMAND 25/50 is a state-of-theart, compact, stand-alone or slave Emergency Voice Evacuation Control Panel (VECP). The FIRE COMMAND 25/50 is offered in a self-contained,
More informationMEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL
March 30, 2000 Section: Audio/Visual Devices G-250 SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL System Sensor SpectrAlert Series strobes, horns, and combination horn/strobes are UL listed
More informationTrueAlert Multi-Candela Notification Appliances
UL, ULC Approved* TrueAlert Multi-Candela Notification Appliances Non-Addressable Visible Only Amber Lens Strobes for Emergency Communications Features Visible only (V/O) 24 VDC wall mount notification
More informationFire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION
Fire Safety Installation Instructions Model SMB- Main Control Board OPERATION The SIEMENS Model SMB- board in each MXL-IQ System controls operations and monitors input device identity, network communication,
More informationSpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E
SpectrAlert Advance Description System Sensor SpectrAlert Advance offers a variety of devices designed for mass notification, including plain devices for non-fire applications, amber lens strobes and speaker
More informationLife safety notification
LED Wheelock Exceder LED3 Life safety notification Meeting the latest codes with increased energy-efficiency in a compact design Wheelock Exceder LED3 Compliant, compatible, compact, and energy efficient
More informationConventional Releasing Control Panel
s Data Sheet Fire Safety Products Conventional Releasing Control Panel Pre-Action Deluge Agent-Releasing Fire System Model TXR-320 Remote configurable Up to two (2) hazard areas Operable with the following:
More informationAL800ULADA. NAC Power Extender. Installation Guide
AL800ULADA NAC Power Extender Installation Guide Rev. 122000 AL800ULADA - NAC Power Extender Overview: The Altronix AL800ULADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery
More informationgood things in small packages
FireShield Control Panels good things in small packages life safety for small buildings and shops A perfect arrangement FireShield offers the very best conventional fire alarm technology available, with
More informationInstallation Guide for AL800UL-ADA. NAC Power Extender. Rev
Installation Guide for AL800UL-ADA NAC Power Extender Rev. 090500 Overview: The Altronix AL800UL-ADA is an extremely cost effective 8 amps voltage regulated remote power supply /battery charger. The AL800UL-ADA
More informationAL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev
AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 031703 Overview: The Altronix AL802ULADA is an extremely cost effective 8 amp voltage regulated
More informationJune 10, 2002 DF C S2424
GENERAL www.firelite.com The Fire Lite FIRE COMMAND 25/50X is a state-of-theart Emergency Voice Evacuation Control Panel (VECP), with significant technological enhancements that set it apart from other
More informationL-Series, Indoor Strobes and Horn Strobes
Notification Appliances L-Series, Indoor Strobes and Horn Strobes Indoor Selectable-Output Horns, Strobes and Horn Strobes for Wall Applications General The L-Series audible visible notification products
More informationACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel
ACC-25/50ZST Zoned System Voice with Telephone Evacuation Control Panel General The AUDIO COMMAND CENTER 25/50 Zone System with FireFighters Telephone (ACC-25/50ZST) is a state-of-the-art Emergency Voice
More informationECC-50/100(E) Emergency Command Center
ECC-50/100(E) Emergency Command Center DF-60734:A9 C-200 General Fire Lite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,
More informationSignature Series Auto-Sync Output Module (CC1S)
Signature Series Auto-Sync Output Module (CC1S) Product description Mounting The Signature Series can be mounted in a North American 2-1/2 in (64 mm) deep 2-gang box or a standard 4 in square box 1-1/2
More informationTrueAlert Addressable Notification Appliances
UL, ULC, CSFM Listed, FM Approved TrueAlert Addressable Notification Appliances Audible/Visible Notification Appliances, Wall Mount Multi-Candela Horn/Strobe, Model Series 49AV Features Individually addressed
More informationFire Safety. Installation Instructions. Model ADBX-11. Audible Base INTRODUCTION. Model ADBX-11
Fire Safety Installation Instructions Model ADBX11 Audible Base INTRODUCTION Model ADBX11 The SIEMENS Model ADBX11 Audible Base consists of a standard Series 11 base combined with an audible device. All
More informationAL600ULADA. NAC Power Extender. Installation Guide
AL600ULADA NAC Power Extender Installation Guide Rev. 122000 AL600ULADA - NAC Power Extender Overview: The Altronix AL600ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery
More informationFIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL
FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL THE GAMEWELL COMPANY PN: 71981 60 PLEASANT STREET ISSUE A ASHLAND, MA 01721 3/22/2001 This page intentionally blank ii
More informationModel 17A00 Expansion Enclosure
HOME AUTOMATION, INC. Model 17A00 Expansion Enclosure Installation Manual Document Number 17I00-1 Rev A March, 2002 Home Automation, Inc. Model 17A00 Expansion Enclosure Installation Manual Document Number
More informationAND ARCHITECT SPECIFICATIONS
SXL Conventional Zone Fire Alarm Control Panel ENGINEER AND ARCHITECT SPECIFICATIONS 4 Zones Expandable to 8 Zones Microprocessor Based Control Factory Programmed Field Configurable 2 Style Y Notification
More informationInstallation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev
Installation Guide for AL600ULM Multi-Output Access Control Power Supply Charger Rev. 091800 1 AL600ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL600ULM multi-output access control
More informationAddressable Fire Alarm Control Panel
PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT
More informationPSN-1000 & PSN 1000(E) Installation Manual
PSN-1000 & PSN 1000(E) Installation Manual Potter Electric Signal Company, LLC St. Louis, MO Customer Service: (866) 240-1870 Technical Support: (866) 956-1211 Fax: (314) 595-6999 www.pottersignal.com
More informationInstallation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger
Installation Guide for AL300ULM Multi-Output Access Control Power Supply Charger R AL300ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL300ULM multi-output access control power supply/charger
More informationRemote NAC Power Supply D7038
Operation and Installation Guide Remote NAC Power Supply D7038 D7038 REMOTE NAC POWER SUPPLY Page 2 2005 Bosch Security Systems Contents Contents 1.0 Overview...5 1.1 Module Control...5 1.1.1 Option Bus
More informations Notification Appliances Mounting Options
s Notification Appliances Mounting Options Mounting Diagrams Mounting Matrixes Mounting Notes Data Sheet Fire Safety Products ARCHITECT AND ENGINEER SPECIFICATIONS 08 Series Notification Appliances 2585
More information30.45 Electric Release PDRP-2001
The PDRP-2001 Fire Alarm Control Panel (FACP) is a six-zone control panel for single and dual hazard deluge and preaction applications. The FACP is compatible with conventional input devices (2-wire or
More informationDimensions of the Optional Mounting Box (BB-400R/W)
Wall and Ceiling Notification Appliances This manual applies to the following models Horn only FH-400-WW and FH-400-RR - wall and ceiling mounted horn Strobe only FS-400-WW and FS-400-RR - wall mounted
More informationPOWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)
PATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262) NAC ETENDER SUPPLIES Installation Instructions 273 Branchport Avenue, Long Branch, NJ 07740-6899 Ph: (800) 631-2148 Fax: (732) 222-8707 Web
More informationInstallation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger
Installation Guide for AL400ULM Multi-Output Access Control Power Supply Charger R AL400ULM - Multi-Output Access Control Power Supply/Charger Rev. 072500 Overview: The AL400ULM multi-output access control
More informationAL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)
AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 042010 Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864).
More informationMR-2602 Two Zone Fire Alarm Control Panel
MR-2602 Two Zone Fire Alarm Control Panel Installation Manual Secutron LT-2015 Rev.3 July 2010 Table of Contents 1 Introduction 1.1 The MR-2602 Fire Alarm Control Unit... 11 1.1.1 General features...
More informationLifeAlarm Fire Alarm Control Panels
LifeAlarm Fire Alarm Control Panels UL, ULC Approved* Features Control panel operator convenience features: Wide viewing angle 2 x 20 (40 character) alphanumeric LCD and dedicated LEDs provide convenient
More informationPWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R
Region Project Page 1 PART 1 - GENERAL 1.1 REFERENCES.1 CAN/ULC-S524-2006, Standard for the Installation of Fire Alarm Systems..2 CAN/ULC-S525-2007, Audible Signal Device for Fire Alarm Systems..3 CAN/ULC-S526-2007,
More informationSAFEPATH SP40/2 D10 D35 AMP P/N P/N Installation, Testing, TONE SW Operation, and W4 Maintenance D54 SHORT
W1 U8 AC N L SAFEPATH4 F2 IN BAT 24V TB7 TB1 AC TBL STB D11GRN YEL RED F1 D13 D14 AC SW1 SW2 RECORD D34 1 2 3 4 SP40/2 D9 D22 DV D10 D35 BAT MIC W2 ON D37 STB SHORT D39 STB OPEN 1 2 3 R SW3 1 2 3 4 TEL
More informationSP-1000X. Panic Device Power Controller Installation Guide. Rev
TM SP-1000X Panic Device Power Controller Installation Guide Rev. 120213 Overview: SP-1000X will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed to handle the high current
More informationTrueAlert Addressable Notification Appliances
UL, ULC Approved* TrueAlert Addressable Notification Appliances Audible Notification Appliances; Multi-Tone Horns with 520 Hz Output Features Individually addressed and controlled TrueAlert ES multi-tone
More informationSECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM
SECTION 283111 - DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationModels NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117
Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel Revision E 61117 CAUTION: (Read This First) This panel has been designed to make it nearly bullet proof to mistakes made when wiring
More informationSpeakers and Speaker Strobes
Kingfisher Company, inc. Speakers and Speaker Strobes Features: Approvals include: UL Standard 1971, UL Standard 1480, New York City (MEA), California State Fire Marshall (CSFM), Factory Mutual (FM), and
More informationSpecification/ Data Sheet
Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)
More informationAddressable NAC Output Module D327A
Installation Instructions Notice Addressable NAC Output Module D327A These instructions cover the installation of the D327A Addressable NAC Output Module in an analog system controlled by a Bosch D8024,
More informationDIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM
DIVISION 26 ELECTRICAL SECTION 26 81 11 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install all equipment and accessories for a complete local, analog addressable, manually and automatically actuated,
More information/5121/5122 TrueAlert Power Supply Installation Instructions
4100-5120/5121/5122 TrueAlert Power Supply Installation Instructions Introduction This publication provides an overview of the features, specifications, and capabilities of the TrueAlert power supplies
More informationIDP-Zone-6 Six Zone Interface Module
INSTALLATION AND MAINTENANCE INSTRUCTIONS IDP-Zone-6 Six Zone Interface Module BEFORE INSTALLING If the modules will be installed in an existing operational system, inform the operator and local authority
More informationAEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays
AEGIS Conventional Fire Alarm-Suppression Control Unit FEATURES Agency Approvals FM Approved FM Approved to ANSI/UL 864, 9th edition FM Approved to ULC-S527-99 Other domestic U.S. approvals/listings pending/
More information/9308 External Battery Chargers Installation Instructions
4081-9306/9308 External Battery Chargers Installation Instructions Introduction This publication describes the installation procedure for an External Battery Charger used with the 4100U or 4100ES System.
More informationTECHNICAL DATA OBSOLETE
Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)
More informationSAFEPATH Mass Notification System (SPMNS)
Supersedes February 2016 SAFEPATH Mass Notification System (SPMNS) SP40S SPB-320 SPB-80/4 SPB-160 PS-8-LP SPMNS-MIC SP4Z-A/B Contents Page SPMNS.... 2-4 SPMNS-MIC...3 Expansion Options SAFEPATH 2-zone
More informationFCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE. Field Charger/Power Supply
One Fire-Lite Place Northford, CT 06472 Phone: (203) 484-7161 FAX: (203) 484-7118 FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE Field Charger/Power
More informationMPC-6000 / MPC-7000 / RND-2
MPC-6000 / MPC-7000 / RND-2 Fire Alarm System Control Unit Installation, Operation and Maintenance Manual Siemens Building Technologies, Inc. 8 Fernwood Road Florham Park, NJ 07932 Tel: (973) 593-2600
More informationInstallation Guide for models:
140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal3FD - 12VDC @ 4.6 amp or 24VDC @ 5.2 amp. - Sixteen (16) PTC protected power-limited outputs.
More informationAL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X
AL1002ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 071508X Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864).
More informationSP40S-D. Kingfisher Company, inc. Features: Description:
Kingfisher Company, inc. SP40S-D Features: Multi-use applications The system can function as an evacuation system, an emergency messaging system, and an employee notification system Fire code applications
More informationModel 3300 Technical Support and Installation Manual
Model 3300 Technical Support and Installation Manual Manual # T15011 Document Revision: A1 1. OVERVIEW 1 2. BASIC OPERATION 1 2.1 General 1 2.2 Field-of-View 2 2.3 Range 2 2.4 Environment 2 2.5 Configuration
More informationAgent Release Control Panel
Agent Release Control Panel System Capacity Annunciators: 8 Electrical Specifications RP-2002 (FLPS-7 Power Supply): 120 VAC, 60 Hz, 3.66 amps RP-2002E (FLPS-7 Power Supply): 240 VAC, 50 Hz, 2.085 amps
More informationAddressable Detectors & Bases
Edwards Signaling Catalog u Intelligent Initiating Addressable Detectors & Bases Detectors: E-PD, E-PHD, E-HD Bases: B4U, RB4U, IB4U, SB4U Overview Edwards intelligent addressable detectors are meticulously
More information4100U City and Relay Cards Installation Instructions
4100U City and Relay Cards Installation Instructions Introduction This publication describes the installation procedure for the following: 4100-6031/6032 City Circuit Cards 4100-6033 Alarm Relay Card Inspecting
More informationD350PL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS
D350PL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS I56-1975-004R Before installing detectors, please thoroughly read the NEMA Guide for
More informationMMF Six Zone Interface Module
Installation and Maintenance Instructions I56-900-005 MMF-0-6 Six Zone Interface Module SPECIFICATIONS Normal Operating Voltage: 5- VDC Stand-By Current: ma Alarm Current: 40 ma (assumes all six LEDs solid
More informationMulti-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.
M Series Multi-Output Access Control Power Supply Chargers Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 3 amp @ 12VDC or 4 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp
More informationInstallation Guide for models:
140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal11F - Power Supply 1: 12VDC @ 3.3 amp or 24VDC @ 3.6 amp. - Power Supply 2: 12VDC @ 3.3 amp
More information