MAXLITE RKT LED Retrofit Kit
|
|
- Julius Allen
- 6 years ago
- Views:
Transcription
1 Operating Instructions MAXLITE RKT LED Retrofit Kit Description and Intended Use The RKT LED Retrofit Kit is a high performance LED Fixture upgrade kit designed to replace the original components inside 2 x2 and 2 x4 fluorescent fixtures. The RKT LED Retrofit Kit is suitable for office, school, hospital and medical facility applications. The panels are fully dimmable and compatible with building controls, motion sensors, timers, and daylight harvesting systems. The design of the panels produces an even, consistent shadowless light. The LEDs enable long life, high lumen maintenance, high CRI, and low maintenance, and are constructed without hazardous materials. Construction The LED carriage is constructed of sheet steel, providing heat sink and thermal control capabilities. Attached are four LED strips, constructed from FR4 resin boards, which are mounted onto the carriage with fasteners and added contact via plastic hold down clips. Provisions are also provided to mount the kit to existing fluorescent ceiling panels. Control With a standard integrated driver, the panels operate with a standard 0-10V wall control, (not included) for wall control dimming. Up to 20 panels can be linked to each master panel. Specifications Model Watts Lumen Volts CCT Weight Dimensions(in) L W D RKT4514U5535DV 55W 4, V 3500K 8 lb /8 2 RKT4514U5541DV 55W 4, V 4100K 8 lb /8 2 RKT4514U5550DV 55W 4, V 5500K 8 lb /8 2 RKT2014U4527DV 45W 3, V 2700K 6 lb RKT2014U4535DV 45W 3, V 3500K 6 lb RKT2014U4541DV 45W 4, V 4100K 6 lb
2 Maxlite RKT LED Retrofit Kit 2
3 General Safety Information 1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 2. Review the diagrams thoroughly before beginning. If you feel you do not have electrical wiring experience, have your fixture installed by a qualified licensed electrician. 3. All electrical connections must be in accordance with local codes, ordinance, and the National Electric Code. If you are unfamiliar with methods of installing electrical wiring, secure the services of a qualified licensed electrician. 4. Before starting the installation, disconnect the power by turning off the circuit breaker or by removing the appropriate fuse at the fuse box. Turning the power off using the light switch is not sufficient to prevent electrical shock. 5. Do not use outdoors. 6. Equipment should be mounted in location and at heights where it will not readily be subject to tampering by unauthorized personnel. 7. Do not use this equipment for other than intended use. 8. All servicing should be performed by qualified personnel only. 1. WARNING - Risk of fire or electric shock. Install this kit only in the luminaires that has the construction features and dimensions shown in the photographs and/or drawings. 2. WARNING - Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation 3. WARNING - Risk of fire or electric shock. Reflector kit installation requires knowledge of fluorescent lighting luminaires electrical systems. If not qualified, do not attempt installation. Contact qualified electrician. 3
4 Fluorescent Wiring Diagram Rapid Start: Instant Start: 1. REMOVE WIRING, LAMPHOLDERS, BALLASTS, OR ANY OTHER ELECTRICAL COMPONENTS ENLEVEY TOUTES LES CONNECTIONS, CABLES, DOUILLE DE LAMPE, BALLAST ET COMPOSANT ELECTRIQUE 2. MIN LAMP COMPARTMENT DIMENSIONS (SEE PG.1 FOR KIT DIMENSIONS). DIMENSIONS DE COMPARTEMENTS DE LAMPE MINIMUM (VOIRE PG.1 POUR DIMENSIONS) 4
5 Retrofit Kit Wiring Diagram Connecting panels to AC source supply: 1. All units must be individually connected to the AC supply ( VAC): Black = Line White = Neutral 2. Line connection to be made to switch lead from source. 5
6 INSTALLATION OF THIS RETROFIT ASSEMBLY REQUIRES A PERSON FAMILIAR THE CONSTRUCTION AND OPERATION OF FLUORESCENT LUMINAIRE ELECTRICAL SYSTEMS AND THE HAZARD INVOLVED CONIFIER L INSTALLATION DE CE NECESSAIRE DE MODERISATION A UNE PERSONNE CONNAISSANT LA CONSTRUCTION ET LE FONCTIONNEMENT DES INSTALLATIONS D ECLAIRAGE FLUORESCENT ET CONSCIENTE DES RISQUES QU ELLES COMPORTENT UNLESS OTHERWISE INDICATED, DO NOT MAKE OR ALTER ANY OPENINGS IN THE COMPARTMENT OF WIRING OR ELECTRICAL COMPONENTS DURING INSTALLATION OF THIS RETROFIT ASSEMBLY. PLUG ALL UNUSED OPENINGS IN THE COMPARTMENT OF WIRING OR ELECTRICAL COMPONENTS A MOINS D INDICATION CONTRAIRE, NE PAS PRATIQUER NI MODIFIER DES OUVERTURES DANS LES COMPARTIMENTS CONTENANT DES CABLES OU DES COMPOSANTS ELECTRIQUES LORS DE L INSTLLATION DE CE NECESSAIRE DE MODERISATION. BOUCHER TOUTES LES OUVERTURES COMPOSANTS ELECTRIQUES TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR OTHER SHARP OBJECTS POUR PREVENIR TOUT DOMMAGE ET USURE, NE PAS EXPOSER LES CIRCUITS AUX BORDS DEL TOLE OU D AUTTRES OBJET POINTUS. DISCONNECT THE POWER BY TURNING OFF THE CIRCUIT BREAKER OR BY REMOVING THE APPROPRIATE FUSE AT THE FUSE BOX. TURNING THE POWER OFF USING THE LIGHT SWITCH IS NOT SUFFICIENT TO PREVENT ELECTRICAL SHOCK. DEBRANCHEZ L ALIMENTATION EN ETEIGNANT LE DISJONCTEUR OU PAR ENLEVER LE CORRECT FUSIBLE DE LA BOITE A FUSIBLES. ETEIGNER L ALIMENTATION EN UTILISANT L INTERRUPTEUR N EST PAS SUFFISANT OUR PREVENIR TOUT DANGER ELECTRIQUE THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT OF A FLUORESCENT LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR AUTHORITIES HAVING JURISDICTION LE NECESSAIRE DE MODERNISATION EST ACCEPTE EN TANT QUE COMPOSANT D UN LUMINAIRE FLUORESCENT, SOUS RESERVE D APPROBATION DE L ENSEMBLE PAR LA CSA OU PAR LES POUVOIRSDE REGLEMENTATION 6
7 Mounting 1. Remove diffuser, fluorescent tubes and all other internal components. Disconnect fluorescent ballast from power wires. 2. Use safety S hook provided to hang Retrofit Kit to the edge of existing fixture. Once secure, attach existing power wires to Retrofit Kit power wires (Black to Black and White to White). 7
8 3. Install the fasteners or self-tapping screws provided with the kit to secure the Retrofit kit to the bottom of existing fixture. The self-tapping screws should have a sleeve provided that helps retain them when put through the panel. They also hold the screw in place for one man operation of installing. 4. Reinstall fixture diffuser. 8
9 Installation & Operation Disconnect the power before installing or serving. Set-up for 0-10V ballast dimmer or building controls: 1. Open access cover 2. Follow connection power on page Connect non relay wires violet/grey from central system to violet/grey wires of driver. 4. Connect relay wires from central system red/blue to red/blue of relay. 5. Connect remaining power wires black from driver to relay line, white wire from driver to relay neutral connect to neutral. 6. Mount panel and operate. 9
10 Set-up for wall dimming (0-10V): 1. Follow connection power on page 5 2. Connect violet and grey wires from wall dimmer to violet and grey wires on driver. 3. Connect appropriate relay pack if necessary. Follow wire diagram provided. 10
11 Set-up for linking panels: 1. Follow connection power on page Select one of the panels to be the master panel. 3. Connect dimmer/central system to this panel. 4. Daisy chain remaining panels in zone by connecting violet/grey wires from panel to panel. 5. Up to 20 panels can be linked together with 20 control wiring between each panel. *Lutron PP-20 power pack relay not included. 6. Use 18/20 AWG for control wires. 11
Lumination TM Volumetric Retrofit Kit
GE Lighting Installation Guide Lumination TM Volumetric Retrofit Kit BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING AVERTISSEMENT RISK OF FIRE OR ELECTRIC SHOCK Luminaire wiring
More informationUSER MANUAL INSTALLATION GUIDE FOR: 2X2: MLFP22DS4035 MLFP22DS4041 MLFP22DS4050
DIRECT LIT LED FLAT PANEL: SAVER SERIES USER MANUAL by INSTALLATION GUIDE FOR: 1X4: MLFP14DS4035 MLFP14DS4041 MLFP14DS4050 2X2: MLFP22DS4035 MLFP22DS4041 MLFP22DS4050 2X4: MLFP24DS4235 MLFP24DS4241 MLFP24DS4250
More informationwww.greenelectricalsupply.com FLATMAX LED FLAT PANEL: PERFORMANCE SERIES USER MANUAL INSTALLATION GUIDE FOR: 1X4: MLFP14DP4535 MLFP14DP4541 MLFP14DP4550 2X2: MLFP22DP4535 MLFP22DP4541 MLFP22DP4550 2X4:
More informationDioluce Products Installation Instructions
Dioluce Products Installation Instructions Models DL-R24-4530-5K0-001 DL-R24-4530-5K0-002 DL-R24-5035-5K0-001 DL-R24-5035-5K0-002 DL-R24-4530-4K0-001 DL-R24-4530-4K0-002 DL-R24-5035-4K0-001 DL-R24-5035-4K0-002
More informationIMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation must be conducted by licensed electrician.
INSTALLATION AND MAINTENANCE MANUAL StarPower Link LED Luminaire (Damp Location) Document No: 0077 Rev B Apr. 2015 IMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation
More informationSAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
ZR Series Commercial Specification Troffers with Emergency Driver Includes: ZR14, ZR22 and ZR24 IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed
More informationPH:
ALL MODELS: THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. CE PRODUIT
More informationInstallation Instructions
Installation Instructions Ordering Code: RF16UQT1XXC RF32UQT1XXC RF32UHT1XX RF45UQT1XXC RF45UHT1XX PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION OF THE FOLLOWING: 4 STRIP FIXTURES 8 STRIP FIXTURES
More informationPH:
ALL MODELS: THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. CE PRODUIT
More information1 x4 Dimmable LED RetroFits
1 x4 Dimmable LED RetroFits Installation Instructions Ordering Code: RF16UQT1XXCDL RF16UHT1XXDL RF32UQT1XXCDL RF32UHT1XXDL PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION OF THE FOLLOWING: 4 STRIP FIXTURES
More informationInnovative Lighting Smooth Light Recessed Luminaires
Installation Guide Innovative Lighting Smooth Light LED Recessed Luminaires BEFORE YOU BEGIN INSTALLATION Read these instructions carefully. Failure to follow these instructions will invalidate the warranty
More informationETG-LRP Series. 4 LED Remote Phosphor Linear Low Bay and High Bay Lighting. Figure 1-2 tube LRP with reflector shown
ETG-LRP Series 4 LED Remote Phosphor Linear Low Bay and High Bay Lighting Figure 1-2 tube LRP with reflector shown 1. INTRODUCTION Advanced LED Remote Phosphor (LRP) lighting provides superior efficacy,
More informationHoneywell Durafit LED Retrofit Kit
Honeywell Durafit LED Retrofit Kit INSTALLATION INSTRUCTIONS LED RETROFIT LUMINAIRE CONVERSION FOR USE ONLY WITH PRODUCTS DESCRIBED AND INSTALLED IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS
More information1 General Description
1 General Description LED Tube Light adopts the new type LED as the light source, using the standard TB tube's end caps, makes it easy to install and replace the traditional fluorescent lamp. The TRF-51894
More informationLED Flat Panel Retrofit
LED Flat Panel Retrofit Installation Instructions For 2 x2, and 2 x4 LED Flat Panel Retrofits (RP Series) PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION INTRODUCTION The LED Flat Panel Retrofit fits
More informationLumination TM Controls Accessory LPL Series Controller Box
Installation Guide Lumination TM Controls Accessory LPL Series Controller Box BEFORE YOU BEGIN Read these instructions completely and carefully. RISK OF FIRE OR ELECTRIC SHOCK Turn power off before inspection,
More informationTetra MAX. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide
Tetra MAX LED Lighting System Installation Guide Volt GEMXRD-W, GEMXHRD-W, GEMXGL-W, GEMXBL-W, GEMXYG-W BEFORE YOU BEGIN Read these instructions completely and carefully. RISK OF ELECTRIC SHOCK Turn power
More informationDo not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
LED Tube Lamp (Linear Fluorescent Replacement) Retrofit Installation Instructions The product package includes the following components: 1. Integral LED Lamp (1 unit) 2. Fixture Warning Label (1 - self-adhesive)
More informationLunera Smart T8 4ft. Installation Guide. Installation Description
Installation Guide Lunera Smart T8 4ft Smart Lamp Replacement for 4ft Fluorescent T8 Type B - Single-Ended, Ballast Bypassed Installation Description The LUNERA SMART T8 4FT lamp functions both as an energy-saving
More informationMaxLite LED Round Pendant Highbay Series
General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More informationCold Door 2 LED Retrofit Kit Lighting System
PAGE 1 OF 6 General Information Cold Door 2 is intended for use inside commercial refrigeration cases with packed foods only. Cold Door 2 LED luminaire should only be used with SloanLED 100 Watt 24 VDC
More informationINSTALLATION INSTRUCTION In-Ground
SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified electrician in accordance
More informationInstallation Instructions
Installation Instructions 42" Island Vent Hood ZV1050 monogram.com 1 Safety Information BEFORE YOU BEGIN Read these instructions completely and carefully. Save these instructions for local inspector s
More informationDimmable LED Retrofit Kit
ASD LED Recessed Retrofit Kit was designed as an energy-efficient lighting solution for remodeling or new construction projects. It is an ideal replacement for an incandescent lamp in the industry s most
More informationLED FLAT PANEL EDGE LIT MLFP SERIES G2
PROJECT NAME: CATALOG NUMBER: NOTES: FIXTURE SCHEDULE: LED FLAT PANEL EDGE LIT SERIES G2 1x4 2x2 Page: 1 of 6 PRODUCT DESCRIPTION: Typically used to replace 1 x4, 2 x2 and 2 x4 fluorescent fixtures, the
More informationINSTALLATION INSTRUCTION In-Ground Color Changing
SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified electrician in accordance
More informationCold Deck FIT. Canopy and Shelf Lights and Retrofit Kit. Installation Guide for General Information. Tools and Accessories Recommended
General Information Cold Deck FIT LED lighting systems are intended for use inside of commercial refrigerated display merchandisers for food zone, splash zone, and non-food zones only. Cold Deck FIT LED
More informationCold Deck Canopy and Shelf Lights and Retrofit Kit
PAGE 1 OF 8 General Information Cold Deck LED lighting systems are intended for use inside of commercial refrigerated display merchandisers for food zone, splash zone, and non-food zones only. Cold Deck
More informationINSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS
POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS READ AND FOLLOW THESE INSTRUCTIONS BEFORE INSTALLATION TO ENSURE PROPER AND SAFE OPERATION SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Flow Lighting QuickLED NEW FIXTURE 2x4 2x2 1x4 Corporate 1240 Texan Trail, Suite 102 Grapevine, TX 76051 (817)435-8484 Office www.flowledlighting.com READ AND FOLLOW ALL SAFETY
More informationCDL8 LED Architectural
Project: Type: Model# CDL8 LED Architectural PRODUCT DESCRIPTION Retrofit Down lights The Luminoso 8 inch Commercial LED Downlight is damp rated, and suitable for 1-277V Input equipped with fire-rated
More informationCXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION
CXB Series LED Luminaire Junction Box, Pendant and Hook and Cord IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND
More informationLED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ
LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION SAFETY INSTRUCTIONS AND WARNINGS WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY
More informationInnovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits
Installation Guide Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits For Commercial Refrigerated Multi-Deck Display Cases BEFORE YOU BEGIN INSTALLATION Read these instructions carefully.
More informationInnovative Lighting R-Series Overhead LED Conversion Kits
Installation Guide Innovative Lighting R-Series Overhead LED Conversion Kits For Commercial Walk-In Coolers and Freezers BEFORE YOU BEGIN INSTALLATION Read these instructions carefully. Failure to follow
More informationLED Emergency Battery Backup
LED Emergency Battery Backup Installation Instructions Ordering Code: PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION: TROFFER INSTALLATION STRIP INSTALLATION INTRODUCTION & TABLE OF CONTENTS Ordering
More informationLED Ceilencio. Specifically designed for
LED Ceilencio by Specifically designed for Ceilencio Ceiling LED Ceilencio JLC-Tech, a pioneer for architecturally integrated LED lighting solutions, has teamed up with Decoustics, a custom ceilings manufacturer,
More informationMaxLite LED VAPOR TIGHT LINEAR FIXTURES
A cost effective LED Vapor Tight Fixture features a full length polycarbonate lens and a one-piece white glass reinforced polyester (GRP) body. Designed to meet or exceed seven to 10 foot-candles at 8
More informationInstallation guide. Philips EvoKit LED 2x4 and 2x2
Installation guide Philips EvoKit LED 2x4 and 2x2 This installation guide is only valid for the following Philips EvoKit models: Products 2x4 EvoKit 2x4 P 36L 36W 835 2 0-0 7 G2 EvoKit 2x4 P 36L 36W 840
More informationTROFFER RETROFIT KIT (TRK)
Not all products are qualified on the DLC QPL. To view our DLC qualified products, please consult the DLC Qualified Products List at www.designlights.org/qpl. TROFFER RETROFIT KIT (TRK) www.trulygreensolutions.com
More informationLED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright
T8 PBT8-DL5004EFX-U AC 100V-277V Day Light 5000K Pure Bright LED retrofits! Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! With the highest safety rating available, UL Listed,
More informationLED Seamless VaporProof Fixture
ASD LED Seamless Premium VaporProof fixture is a modern contemporary lighting fixture widely used in many different commercial and residential environments. It has many features that make it the perfect
More informationFES - Series Portable Electric Heaters
FOSTORIA INDUSTRIES 114 Roscoe Fitz Road Gray, TN 37615 Phone: 800-495-4525 Fax: 419-435-0842 www.fostoriaindustries.com Division of TPI Corporation YES - Series Suspended Electric Heaters FES - Series
More informationSERVICE BY QUALIFIED PERSONNEL ONLY
Installation Instructions Automatic Load Control Relay For Emergency Lighting! IMPORTANT SAFEGUARDS! WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:
More informationLED Dusk to Down Fixture
LED Dusk to Down Fixture Features UL cul DLC certificate PHILIPS Chip, high CRI Mean Well IP65 driver,input voltage 100-277VAC No UV or IR in the beam Easy to install and operate Energy saving, long lifespan
More informationInnovative Lighting R-Series Vertical Refrigeration
Installation Guide Innovative Lighting R-Series Vertical Refrigeration Door LED Conversionn Kits For Commercial Refrigerators and Freezers BEFORE YOU BEGIN INSTALLATION Read these instructions carefully.
More informationWarmup DS-2C RAIN/SNOW SENSOR CONTROLLER INSTALLATION MANUAL AUTOMATED SYSTEMS ENGINEERING ENCLOSURE TYPE 3R
CM CAUTION: Read all instructions carefully before installation. Save this Installation Manual for future reference. Warmup DS-2C RAIN/SNOW SENSOR CONTROLLER INSTALLATION MANUAL ENCLOSURE TYPE 3R AUTOMATED
More informationBAYMAX TM LED LINEAR HIGHBAY FIXTURE BLHT SERIES
PROJECT NAME: CATALOG NUMBER: NOTES: FIXTURE SCHEDULE: Page: 1 of 5 BAYMAX TM LED LINEAR HIGHBAY FIXTURE FEATURES: High Efficacy LED boards with dual copper cladding for thermal dissipation 1-1V Dimming
More informationEscape Series Walk-in Bathtub Models 5128 and 5332 (soaker, water, air and microbubble jet models)
INSTALLATION INSTRUCTIONS Escape Series Walk-in Bathtub Models 58 and 5 (soaker, water, air and microbubble jet models) 09 Includes instructions for: Models with an end panel for corner installations and
More informationDESIGNED SPECIFICALLY FOR QUICK AND EASY WATERPROOF INSTALLATION.
UFO LED High Bay H03CO Shop & Retial Architectural Semi-outdoor Education Industrial E465485 Premium DESIGNED SPECIFICALLY FOR QUICK AND EASY WATERPROOF INSTALLATION. Waterproof LED High Bay by Ervan makes
More informationAPPLICATIONS SPECIFICATION FEATURES ORDERING. Project: Notes: Catalog #: Large Outdoor Spaces. Swimming Pools. Shopping Malls. Large Indoor Spaces
Project: Notes: Type: Catalog #: Date: LED UFO HIGHBAY PT-HBA-100W SERIES APPLICATIONS Large Outdoor Large Indoor Industrial Areas Churches Swimming Pools Shopping Malls Warehouses Commercial Gymnasiums
More informationINSTALLATION INSTRUCTIONS
WHEN REPLACING PCB ASSEMBLIES, PLEASE WEAR AN ESD WRIST STRAP AND CONNECT IT TO ELECTRICAL GROUND RISK OF FIRE AND ELECTRICAL SHOCK Contact, improper installation, or improper servicing MAY RESULT IN DEATH
More informationLED Shoplight fixture
ASD LED Shoplight Fixtures are perfectly suitable for all general-purpose applications found throughout the home, office, and warehouse.. Having a contemporary outlook, fixtures are very easy and convenient
More informationInstallation Instructions
Installation Instructions Ordering Code: RF32UQT1XX PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION OF THE FOLLOWING: 4 STRIP FIXTURES 8 STRIP FIXTURES HARDWIRE 4 STRIP FIXTURES WRAP FIXTURES TROFFER
More informationDHL-LP-LED Low Profile LED Linear High/Low Bay
IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions
More informationHIGH LUMINOUS EFFICIENCY
Warehouses, factories, and other industrial facilities have always relied on high bay lighting to provide bright light to large spaces. Now, ASD offers an all-in-one solution to these lighting applications.
More informationLED Lighting: Technology Selection and System Commissioning Course Number: CXENERGY1519
AABC Commissioning Group AIA Provider Number: 50111116 LED Lighting: Technology Selection and System Commissioning Course Number: CXENERGY1519 Michael Chow, P.E., CxA, LEED AP BD+C, Metro CD Engineering
More informationI-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT
P.O. BOX 84 TUCSON, AZ 85734 (520) 294-3292 FAX (520) 74-2837 www.iotaengineering.com INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be
More informationCatalog Number. Notes
Catalog Number FEATURES & SPECIFICATIONS INTENDED USE Built on the compact, low-profile Z strip channel, this LED strip offers long maintenance-free life, several color s, lumen outputs and lengths. Ideal
More informationwith motion sensor ITM. / ART Model: LM55811 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY
LED Utility Light with motion sensor ITM. / ART. 688836 Model: LM55811 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY For assistance with assembly or installation, parts
More informationESRB and ESRN Installation & Safety Instructions
B1784 ESRB and ESRN Installation & Safety Instructions IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW
More informationEMERGENCY POWERHUBB NODE INSTALLATION AND OPERATION GUIDE
EMERGENCY POWERHUBB NODE INSTALLATION AND OPERATION GUIDE MODEL NUMBERS PHM4PC-xxxx-EM PHS4PC-xxxx-EM PRECAUTIONS Read and understand all instructions before beginning installation NOTICE: Follow National
More informationWARRANTY LED ECO PANEL.
LED ECO PANEL www.trulygreensolutions.com 8 MODELS AVAILABLE IN 25W TO 72W EXPECTED LIE OVER 50,000 HRS Compatible Emergency Battery Backup Available eatures 5 YEAR Suitable or Damp Location Use IES ILES
More informationSylproof Superia LED G2
Range Features 665mm, 1265mm, 1565mm single and twin weatherproof LED luminaires Impresive performance, up to 7,837lm (luminaire lument output on 80W twin / double version) High efficiency, will help you
More informationDouglas Lighting Controls. Bluetooth Fixture Controller & Sensor. Installation Manual BT-FMS-A. *Patent Pending. Installation Guide BT-FMS-A v7
Bluetooth Fixture Controller & Sensor BT-FMS-A Installation Manual *Patent Pending www.douglaslightingcontrols.com 1 This page intentionally blank. www.douglaslightingcontrols.com 2 WARNING! SYSTEM MUST
More informationCatalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser
Catalog Number FEATURES & SPECIFICATIONS INTENDED USE Built on the compact, low-profile Z strip channel, this LED strip offers long maintenance-free life, several color s, lumen outputs and lengths. Ideal
More informationHIGH BAY APPLICATIONS
STAIRWELLS The IIS Inverter can operate multiple fixtures in a building s stairwell and can be wired to bypass dimmers or occupancy sensors...keeping your egress corridors lit without sacrificing your
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS FHSKIT-T04LNX or FHSKIT-TXXXHX TABLE OF CONTENTS 1.0 INSTALLATION INSTRUCTION WARNINGS... PAGE 3 2.0 ORIGINAL FIXTURE PARTS... PAGE 4 3.0 HOTSPOT LED KIT PARTS... PAGE 5-6 4.0
More informationPEDESTAL INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION DU PIÉDESTAL
PEDESTAL INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION DU PIÉDESTAL Table of Contents PEDESTAL SAFETY... 1 INSTALLATION REQUIREMENTS... 2 Tools and Parts... 2 Location Requirements... 2 Before
More informationSOLA SM II Light Engine Instruction Manual
SOLA SM II Light Engine Instruction Manual Lumencor, Inc. Document Number 52-10036 www.lumencor.com Emissions Certifications This equipment has been tested and found to comply with the limits of EMC directive
More informationClassix 6" 6" Round Adjustable C3
Classix 6" Features The Classix Adjustable downlight shines new light on your bigger jobs. With a unique Amerlux blend of architectural form and function, Classix performs perfectly in large retail and
More informationSAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400
INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400 CAUTION: For safety and proper operation, read and follow instructions carefully before installation. FIELD INSTALLABLE
More informationInstallation Instructions If you have questions, call or visit our website at:
Installation Instructions If you have questions, call 800.626.2000 or visit our website at: www.monogram.com Wine Reserve ZDWT240 and Beverage Center ZDBT240 Design Guide With Installation Instructions
More informationCHALICE RECESSED LED DOWNLIGHT 70 Watt LED
CHALICE RECESSED LED DOWNLIGHT 70 Watt LED The Chalice 70 recessed LED downlight follows the Altman Lighting tradition of lighting quality. Designed specifically for the demands of theaters, churches and
More informationInstallation Instructions
Design Guide with Installation Instructions Wine Reserve ZDWT240 and Beverage Center ZDBT240 monogram.com Safety Information BEFORE YOU BEGIN: Read these instructions completely and carefully. IMPORTANT
More informationLED ROUND MINI PANELS
Our ASD LED Round Mini Panel is a cutting-edge choice for indoor lighting for both residential and commercial applications. This round lit mini panel features low energy consumption, a year warranty and
More informationTHINTEK G2 PANEL.
t all products are qualified on the DLC QPL. o view our DLC qualified products, please consult the DLC Qualified Products List at www.designlights.org/qpl. HINEK PANEL www.trulygreensolutions.com HINEK
More informationTHINTEK G2 PANEL.
t all products are qualified on the DLC QPL. o view our DLC qualified products, please consult the DLC Qualified Products List at www.designlights.org/qpl. HINEK PANEL www.trulygreensolutions.com HINEK
More informationInstallation Instructions If you have questions, call 800-GE-CARES or visit our website at:
Installation Instructions If you have questions, call 800-GE-CARES or visit our website at: www.monogram.com 30" Convection Built-In Ovens Models: ZET1038 ZET1058 Monogram. We bring good things to life.
More informationCanadian Model Number Designations. Models ending in... LED-8030M42 C-A = 347V LED-8030M42 -A = 120/277V LED-8030M42 C = 120/347V
Canadian Model Number Designations Models ending in... -8030M42 C-A = 347V -8030M42 -A = 120/277V -8030M42 C = 120/347V ff LM-80 LM-79 RoHS IP64 RATED Suitable for open fixtures only Ballast Bypass Internal
More informationCLM 422 Series LED Ceiling Luminaire Module - 45Watt
Product Information The CLM422 LED Ceiling Luminaire Module is the first truly engineered commercial grade (2'x 2') LED office light designed to replace fluorescent fixtures of much higher wattage classes.
More informationMaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights
General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More informationClassix 6" 6" Round Lens Wall Wash
Features The Classix Lensed Wall Wash shines new light on your bigger jobs. With a unique Amerlux blend of architectural form and function, Classix performs perfectly in large retail and commercial spaces.
More informationNew LED Product Offerings
New LED Product Offerings from we know light. TCP LED NEW Product Offerings LED Indoor Lighting PL Lamps EdgeLit Downlights HID DirecT8/DirecT5 T8/T5 Tubes Liscio by TCP Linear Accent Lighting Luxterior
More informationClassix 6" 6" Round Lens Wall Wash
Features The Classix Lensed Wall Wash shines new light on your bigger jobs. With a unique Amerlux blend of architectural form and function, Classix performs perfectly in large retail and commercial spaces.
More informationPremium. Universal LED Vapor Tight T20G. Commercial lighting Industrial lighting Vapor tight light Linear High Bay Canopy
Universal LED Vapor Tight T20G Commercial lighting Industrial lighting Vapor tight light Linear High Bay Canopy E465485 Premium MULTI INSTALLATION WAYS TO SAVE YOUR LABOR COST. The T20G is a tri-proof
More informationFino Healthcare. Asymmetric Wall Mount Indirect LED
Fino Healthcare Asymmetric Wall Mount Indirect LED Features fiture is ideal for applications requiring a wipe down lens with no horizontal "shelf" surfaces. Designed with an integrated acrylic lens to
More informationClassix 6" 6" Round Adjustable C3
Classix 6" Features The Classix Adjustable downlight shines new light on your bigger jobs. With a unique Amerlux blend of architectural form and function, Classix performs perfectly in large retail and
More informationProduct Specifications
//206 00 VLN0 Product Specifications Nastro LED High Bay W Nastro LED High Bay EO-LN- EO-LN-T EO-LN-HV EO-LN-HVT Linear Design System Light Efficacy LPW Easy Installation & Maintenance IP6/ IP30(PIR) Five
More informationLED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle
GreenLight cooperative Product Specifications LED High Bay W LED High Bay GLC-ANHB-W- Linear Design System Light Efficacy >0 LPW Easy Installation & Maintenance IP6/ IP30(PIR) Five Years Warranty ETL,
More informationProject Name. Date. Cat. Number. Type
Linear Series 2.0 LED linear luminaires and retrofit linear kits The Linear Series delivers ultra-long life and high efficacy. Fixtures can be installed independently or joined together for continuous-run
More informationAB Parts. ControlNet Coax Tap. Installation Instructions. (Cat. Nos TPR, -TPS, -TPYR, -TPYS) What s in This Document
Installation Instructions ControlNet Coax Tap (Cat. Nos. 1786-TPR, -TPS, -TPYR, -TPYS) What s in This Document Use this document as a guide when installing a ControlNet coax tap. To: See Page: verify package
More informationMODELS SafeSite LED Linear, Class I Div. 1 2 & 4 Versions
INSTALLATION AND MAINTENANCE MANUAL SAFESITE LED LINEAR FIXTURE Document No: 9100-127-1402-99 Rev K December, 2016 MODELS SafeSite LED Linear, Class I Div. 1 2 & 4 Versions SUITABLE FOR WET LOCATIONS in
More informationLED FIXTURE CATALOG. Shining light into the future
LED FIXTURE CATALOG Shining light into the future Company Profile Ohyama Lights, LLC strives to be an innovative company that is responsive to its customers needs. Our mission is to put the customer first
More informationPRELIMINARY 2000K PERFORMANCE. CRI Lumen Maintenance Binning Tolerance Warranty
5005332 CLOSET RATED NITELIGHT CLOSET ROD provides even illumination of clothing in a closet while serving as a sturdy and attractive clothes hanging solution. While all necessary accessories for mounting
More informationClassix 6" 6" Round Adjustable C3M
Classix 6" Features The Classix Adjustable downlight shines new light on your bigger jobs. With a unique Amerlux blend of architectural form and function, Classix performs perfectly in large retail and
More informationHi-lume 3D Overview. Fluorescent Dimming Ballasts Hi-lume 3D Architectural Dimming
Fluorescent Dimming s Hi-lume 3D Architectural Dimming Hi-lume 3D Overview 369-280f 1 03.08.12 Hi-lume 3D architectural electronic dimming ballasts are designed to meet the most demanding lighting requirements.
More informationLED ECO PANEL.
our DC qualified products, please consult the DC Qualified Products ist at www.designlights.org/qpl. www.trulygreensolutions.com 8 MODES AVAIABE IN 30W TO 75W EXPECTED IE OVER 50,000 HRS Multiple umen
More informationLED RETROFIT SOLUTIONS
The adoption of LED technology for general illumination systems is considered the attractive choice when compared against traditional linear fluorescent lamps. Engineered Products Company (EPCO) LED RetroFit
More informationLED ECO PANEL.
Not all products are qualified on the DC QP. To view our DC qualified products, please consult the DC Qualified Products ist at www.designlights.org/qpl. ED ECO PANE www.trulygreensolutions.com ED ECO
More information