FCX-11AB5-3XX-XX 155Mbps BIDI SFP TRANSCEIVER(100Km)

Size: px
Start display at page:

Download "FCX-11AB5-3XX-XX 155Mbps BIDI SFP TRANSCEIVER(100Km)"

Transcription

1 FEATURES LC or SC receptacle optical interface compliant Single 3.3V power supply Hot-pluggable Uncooled 1490nm DFB laser transmitter Receiver loss of signal output AC/AC Coupling according to MSA Transmitter disable input DDM function implemented External calibration Serial ID module on MOD(0-2) International Class 1 laser safety certified RoHS complian APPLICATIONS SDH/STM-1,SONET/OC-3 Metropolitan area network STANDARD Compliant with Rev10.2 SFF-8472 Compliant with ITU-T G.957 STM-1 Compliant with SFP MSA(INF-8074i) Absolute Maximum Ratings Parameter Symbol Min. Max. Units Note Storage Temperature Ts Power Supply Voltage Vcc V Soldering Temperature seconds on leads only Recommended Operating Conditions Parameter Symbol Min. Typ. Max. Units Note Operating Supply Voltage Vcc V Operating Temperature Top 0 70 FCX-11AB5-3CX-XX FCX-11AB5-3TX-XX Data Rate 155 Mbps Power Supply Current(1) Icc ma - 1

2 Transmitter Specifications FCX-11AB5-3XX-XX Parameter Symbol Min. Typ. Max. Units Optical Optical Transmit Power Po -2 3 dbm Optical Center Wavelength λc nm Output Spectrum Width Δλ 1 nm SMSR 30 db Extinction Ratio ER db Output Eye Compliance with ITU-T G.957 Optical Rise Time tr ns Optical Fall Time tf ns Jitter(2) TJ 0.1 Uip-p Relative Intensity Noise(3) RIN -116 db/hz Electrical Data Input Current Low IIL -350 ua Data Input Current High 350 A Differential Input Voltage VIH -VIL mv TX Disable Input Voltage-Low TDL V TX Disable Input Voltage-High TDH VCC V TX Disable Assert Time TDAT 10 us TX Disable Deassert Time TDDT 1 ms TX Fault Output Voltage-Low TFL V TX Fault Output Voltage-High TFH 2.0 VCC+0.3 V Receiver Specifications Parameter Symbol Min. Typ. Max. Units Optical Sensitivity(4) Sen -37 dbm Overload Pin -3 dbm Signal Detect -- Asserted Pa -38 dbm Signal Detect -- Deasserted Pd -45 dbm Signal Detect Hysteresis(5) Phys 1 5 db Wavelength of Operation λ nm Electrical Differential Output Voltage VOH VOL mv Output LOS Voltage Low VOH mv Output LOS Voltage High VOL VCC+300 mv Note1: The supply current includes SFP module s supply current and test board working current. Note2: For the jitter measurements, the device was driven with SONET OC-3 data pattern with PRBS payload. - 2

3 Note3: RIN is the laser noise, integrated over a specified bandwidth, measured relative to average optical power with 12dB return loss. Note4: Measured with a PRBS test EX=10dB, BER< Note5: The LOS Hysteresis to minimize chatter on the output line. In principle, Hysteresis alone does not guarantee chatter-free operation.pin ASSIGNMENT Pin Name Function/Description 1 VeeT Transmitter Ground 2 TX Fault Transmitter Fault Indication 3 TX Disable Transmitter Disable-Module disables on high or open 4 MOD-DEF2 Module Definition 2-Two wire serial ID interface 5 MOD-DEF1 Module Definition 1-Two wire serial ID interface 6 MOD-DEF0 Module Definition 0-Two wire serial ID interface 7 Rate Select Not Connected 8 LOS Loss of Signal 9 VeeR Receiver Ground 10 VeeR Receiver Ground 11 Veer Receiver Ground 12 RD- Inverse Received Data out 13 RD+ Received Data out 14 VeeR Receiver Ground 15 VccR Receiver Power V±5% 16 VccT Transmitter Power V±5% - 3

4 17 VeeT Transmitter Ground 18 TD+ Transmitter Data In 19 TD- Inverse Transmitter Data In 20 VeeT Transmitter Ground Note1: TX Fault is open collector/drain output which should be pulled up externally with a 4.7K- 10KΩresistor on the host board to supply <VccT+0.3V or VccR+0.3V. When high, this output indicates a laser fault of some kind. Low indicates normal operation. In the low state, the output will be pulled to <0.8V. Note2: TX Disable input is used to shut down the laser output per the state table below. It is pulled up within the module with a K resistor. Low (0 0.8V): Transmitter on Between (0.8V and 2V): Undefined High (2.0 VccT): Transmitter Disabled Open : Transmitter Disabled Note3: Mod-Def 0, 1, 2. These are the module definition pins. They should be pulled up with a K resistor on the host board to supply less than VccT+0.3V or VccR+0.3V. Mod-Def 0 is grounded by the module to indicate that the module is present. Mod-Def 1 is clock line of two wire serial interface for optional serial ID. Mod-Def 2 is data line of two wire serial interface for optional serial ID. Note4: LOS (Loss of signal) is an open collector/drain output which should be pulled up externally with a K resistor on the host board to supply <VccT+0.3V or VccR+0.3V. When high, this output indicates the received optical power is below the worst case receiver sensitivity (as defined by the standard in use). Low indicates normal operation. In the low state, the output will be pulled to <0.8V. Block Diagram SD RD+ RD- Limiting Amplifier Preamplifi -er Photo Detector Optical Signal Input MOD_DEF(2) MOD_DEF(1) MOD_DEF(0) DDMI& EEPROM RX_Power WDM TD- TD+ Laser Bia TX_Power LD Driving Circuit and Control Circuit Laser Diode Optical Signal Output TX_Disable TX_Fault - 4

5 Application Circuit Digital Diagnostic Memory map - 5

6 EEPROM Serial ID Memory Contents FCX-11AB5-3XX-XX Accessing Serial ID Memory uses the 2 wire address X (A0). Memory Contents of Serial ID are shown in the Table 1. Table 1: Serial ID Memory Contents Data Size Address (Bytes) Name of Field Contents(Hex) Description BASE ID FIELDS 0 1 Identifier 03 SFP 1 1 Ext.Identifier 04 SFP function is defined by serial ID only 2 1 Connector 07 LC Connector Transceiver Transceiver Codes 11 1 Encoding 03 NRZ 12 1 BR,Nominal Mbit/s 13 1 Reserved Length(9um)km 15 1 Length(9um) 16 1 Length(50um) 17 1 Length(62.5um) 18 1 Length(Copper) 00 Not compliant 19 1 Reserved Vendor name 42 4F 54 4F 4E Reserved Vendor OUI Transceiver transmit distance BOTONE (ASCII) Vendor PN Transceiver part number Vendor rev Wavelength 05 1E/06 0E 62 1 Reserved CC_BASE Options 00 1A 66 1 BR,max BR,min Vendor SN Transceiver wavelength example 1310/1550 Check Sum Check code for Base ID Fields (Variable) EXTENDED ID FIELDS TX_DISABLE, TX_FAULT and Loss of Signal implemented. Serial Number of transceiver (ASCII). For example

7 Date code Manufactory date code. For example Digital diagnostic monitoring implemented, 92 1 Diagnostic externally calibrated / internally calibrated is 58 Monitoring Type implemented, RX measurement type is Average Power Optional Alarm/Warning flags implemented for all Enhanced monitored quantities, Optional Soft TX_FAULT B0 Options monitoring implemented, Optional Soft RX_LOS monitoring implemented SFF_8472 Includes functionality described in Rev Compliance SFF CC_EXT Check Sum (Variable) Check sum for Extended ID Field. VENDOR SPECIFIC ID FIELDS Vendor Specific Read only Depends on customer information Reserved Read only Filled by zero Diagnostic Monitor Functions Diagnostic Monitor Functions interface uses the 2 wire address X (A2). Memory contents of Diagnostic Monitor Functions are shown in Table 2 Table 2: Memory contents of Diagnostic Monitor Function Data Address Field Size (bytes) Name Contents and Description Alarm and Warning Thresholds 9 2 Temperature High Alarm On select Temperature Low Alarm On select Temperature High Warning On select Temperature Low Warning On select Vcc High Alarm Set to 3.6 V Vcc Low Alarm Set to 3.0 V Vcc High Warning Set to 3.5 V Vcc Low Warning Set to 3.1 V Bias High Alarm 2 Ibias(25 o C ) Bias Low Alarm 25% IBias (25 o C ) Bias High Warning 2 IBias(25 o C ) Bias Low Warning 50% IBias(25 o C ) TX Power High Alarm Manufacture measurement plus 2dB TX Power Low Alarm Manufacture measurement minus 2dB TX Power High Warning Manufacture measurement plus 1dB TX Power Low Warning Manufacture measurement minus 1 db - 7

8 RX Power High Alarm Maximum input optical power RX Power Low Alarm Minimum input optical power RX Power High Warning Maximum input power minus 3dB RX Power Low Warning Manufacture measurement plus 3dB Reserved Calibration Constants RX Power Calibration Data RX Power Calibration Data3 Single precision floating-point numbers (various RX Power Calibration Data2 values at each device) RX Power Calibration Data RX Power Calibration Data Bias Calibration Data (fixed) Bias Calibration Data (fixed) TX Power Calibration Data (fixed) TX Power Calibration Data (fixed) Temperature Calibration Data (fixed) Temperature Calibration Data (fixed) Vcc Calibration Data (fixed) Vcc Calibration Data (fixed) Reserved (fixed) 95 1 Check Sum Checksum of bytes 0-94 Real Time Diagnostic Monitor Interface Measured Temperature Yield to a 16-bit A/D value (see Table 2.1) Measured Vcc Yield a 16-bit A/D value (see Table 2.1) Measured Bias Yield a 16-bit A/D value (see Table 2.1) Measured TX Power Yield a 16-bit A/D value (see Table 2.1) Measured RX Power Yield a 16-bit A/D value (see Table 2.1) Reserved Logic Status See Table AD Conversion Updates See Table Alarm and Warning Flags See Table 2.3 Vendor Specific Vendor Specific Don t Access User writable EEPROM Vendor Specific Don t Access The measured values located at bytes (in the 2 wire address 0xA2) are raw A/D values (16-bit integers) of transceiver temperature, supply voltage, laser bias current, laser optical output power and received power. All the measured values are Externally Calibrated, and then it is necessary to convert raw A/D values to real world units by the manner as shown in Table

9 Table 2.1: Real Time Diagnostic Monitor Values FCX-11AB5-3XX-XX Byte Name Description 96 Temperature MSB 97 Temperature LSB 98 Vcc MSB 99 VCC LSB 100 Laser Bias MSB 101 Laser Bias MSB 102 Tx Power MSB 103 TX Power LSB 104 Rx Power MSB 105 RX Power LSB Internally measured transceiver temperature. Comply with External Calibration of SFF Internally measured supply voltage. Comply with External Calibration of SFF Measured Laser bias current. Comply with External Calibration of SFF Measured Tx power. Comply with External Calibration of SFF Measured Tx power. Comply with External Calibration of SFF This transceiver implements two optional status bytes, Logic States at byte 110(0xA2) and A/D Updated at byte 111(0xA2) as shown in Table 3.2. A/D Updated status bits allow the user to verify if an update from the analog-digital conversion has occurred of the measured values, temperature, Vcc, laser bias, Tx power and Rx power. The user writes the byte to 0x00. Once a conversion is completed for a given value, its bit will change to 1. Table 2.2:Logic Status and AD Conversion Updates Byte Bit Name Description Tx Disable State Optional digital State of the Tx Disable input pin Soft Tx Disable Control Not supported (set to 0) Reserved Set to Rx Rate Select State Not supported (set to 1) Soft Rate Select Control Not supported (set to 0) Tx Fault Optional digital state of the Tx Fault output pin LOS Optional digital state of the LOS output pin Power on Logic Bit will be 0 when the analog monitoring is active Temp A/D Valid Indicates A/D value in Bytes 96/97 is valid Vcc A/D Valid Indicates A/D value in Bytes 98/99 is valid Laser Bias A/D Valid Indicates A/D value in Bytes 100/101 is valid Tx Power A/D Valid Indicates A/D value in Bytes 102/103 is valid Rx Power A/D Valid Indicates A/D value in Bytes 104/105 is valid Reserved Set to Reserved Set to Reserved Set to 0. Each of the measured values has a corresponding high alarm, low alarm, high warning and low warning threshold level at location 00-39(x0A2) written as the data format of a corresponding valued shown in Table 2.3.Alarm and warning flags at bytes (0xA2) are defined as follows. [1] Alarm flags indicate conditions likely to result (or have resulted) in link failure and cause for immediate - 9

10 action. FCX-11AB5-3XX-XX [2] Warning flags indicate conditions outside the guaranteed operating specification of transceiver but not necessarily causes of immediate link failures. Table 2.3:Alarm and Warning Flags Byte Bit(s) Name Description Temperature High Alarm Set when temperature monitor value exceeds high alarm Temperature Low Alarm Set when temperature monitor value exceeds low alarm Vcc High Alarm Set when Vcc monitor value exceeds high alarm Vcc Low Alarm Set when Vcc monitor value exceeds Low alarm Laser Bias High Alarm Set when laser bias monitor value exceeds high alarm Laser Bias Low Alarm Set when laser bias monitor value exceeds low alarm Tx Power High Alarm Set when Tx power monitor value exceeds high alarm level Tx Power Low Alarm Set when Tx power monitor value exceeds low alarm Rx Power High Alarm Set when Rx power monitor value exceeds high alarm level Rx Power Low Alarm Set when Rx power monitor value exceeds low alarm level Reserved All bits set to Reserved All bits set to Reserved All bits set to Temperature High Set when temperature monitor value exceeds high warning warning Temperature Low Set when temperature monitor value exceeds low warning warning Vcc High warning Set when Vcc monitor value exceeds high warning Vcc Low warning Set when Vcc monitor value exceeds Low warning Laser Bias High warning Set when laser bias monitor value exceeds high warning Laser Bias Low warning Set when laser bias monitor value exceeds low warning Tx Power High warning Set when Tx power monitor value exceeds high warning level Tx Power Low warning Set when Tx power monitor value exceeds low warning Rx Power High warning Set when Rx power monitor value exceeds high warning level Rx Power Low warning Set when Rx power monitor value exceeds low warning level Reserved All bits set to

11 Reserved All bits set to Reserved All bits set to 0. PACKAGE DIAGRAM (Units in mm) 1) FCL-11AB5-3XX-XX(Receptacle:LC) 2) FCS-11AB5-3XX-XX(Receptacle:SC) - 11

12 ORDER INFORMATION FCX-11AB5-3XX-XX D=DDM SFP,T=Without DDM Operating temperature:c=0~70 C,T=-40~85 C Receptacle:S=SC,L=LC - 12

1.25G SFP transceiver with DDM function. RTXM191-xxx (DDM) Features

1.25G SFP transceiver with DDM function. RTXM191-xxx (DDM) Features 1.25G SFP transceiver with DDM function RTXM191-xxx (DDM) Features Up to 1.25Gbps data rate Duplex LC receptacle optical interface compliant Single +3.3V power supply DDM function implemented External

More information

FPS CL Burst Mode SFF BIDI EPON ONU TRANSCEIVER(20Km)

FPS CL Burst Mode SFF BIDI EPON ONU TRANSCEIVER(20Km) FEATURES Dual Wavelength Bi-Directional Tx/Rx 1.25Gbps/1310nm Burst Mode Transmitter 1.25Gbps/1490nm CW Mode Receiver IEEE 802.3ah Compliant Single 3.3 Voltage Supply 2X10 SFF Package Outline Single Fiber

More information

GPON OLT Optical Transceiver SFP Module RTXM RTXM Features

GPON OLT Optical Transceiver SFP Module RTXM RTXM Features GPON OLT Optical Transceiver SFP Module RTXM167-522 Features Integrated Single fiber bi-directional optical subassembly 1310nm Burst-mode APD/TIA receiver and 1490nm Continuous DFB laser Transmitter (with

More information

1000BASE BX-10 SFP Transceiver modules (with DDM function) WST-SxSCx1-D5CH Series

1000BASE BX-10 SFP Transceiver modules (with DDM function) WST-SxSCx1-D5CH Series DataSheet Features: 1.25Gbps data rate 1000Base BX-10 -D Single LC receptacle optical interface Transmitter disable input International Class 1 laser safety certified Single +3.3V power supply 1000Base

More information

EPON ONU Optical Transceiver SFF Module

EPON ONU Optical Transceiver SFF Module EPON ONU Optical Transceiver SFF Module SYFE420 Features Integrated Single fiber bi-directional optical subassembly SC receptacle optical interface 1310nm FP laser Burst-mode Transmitter and 1490nm PIN

More information

LCP-6144A4EDRx. 10GBASE-SR SFP+ Optical Transceiver FEATURES. Description. Applications. RoHS compliant. Compliant to SFP+ Electrical MSA SFF-8431

LCP-6144A4EDRx. 10GBASE-SR SFP+ Optical Transceiver FEATURES. Description. Applications. RoHS compliant. Compliant to SFP+ Electrical MSA SFF-8431 10GBASE-SR SFP+ Optical Transceiver FEATURES RoHS compliant Compliant to SFP+ Electrical MSA SFF-8431 Compliant with SFF-8472 MSA Compliant with CPRI protocols for wireless base station Standard LC duplex

More information

LCP-10G3B4QDRx-G. 10GBASE-LR SFP+ Optical Transceiver FEATURES. Description. Applications. Performance. RoHS compliant

LCP-10G3B4QDRx-G. 10GBASE-LR SFP+ Optical Transceiver FEATURES. Description. Applications. Performance. RoHS compliant 10GBASE-LR SFP+ Optical Transceiver FEATURES RoHS compliant Compliant to SFP+ Electrical MSA SFF-8431 Compliant with SFF-8472 MSA Standard LC duplex fiber-optic connector I 2 C for integrated Digital Optical

More information

LCP-10G3B4HDR(T)-G. 10GBASE-LR Lite SFP+ Optical Transceiver. Description. Applications. Performance FEATURES. RoHS compliance

LCP-10G3B4HDR(T)-G. 10GBASE-LR Lite SFP+ Optical Transceiver. Description. Applications. Performance FEATURES. RoHS compliance 10GBASE-LR Lite SFP+ Optical Transceiver FEATURES RoHS compliance Compliant with SFP transceiver SFF-8472 MSA specification 1310nm FP laser Built-in digital diagnostic monitoring function Compliant with

More information

Stratos Optical HD/SD BNC to "ST" Video Media Converter (Transmitter)

Stratos Optical HD/SD BNC to ST Video Media Converter (Transmitter) FEATURES: SMPTE 292M/297M/259M/305M compliant (VMC-T- H-2) SMPTE 259M/297M/305M compliant (VMC-T-S-2) DVB/ASI compliant (VMC-T-H-2 and VMC-T-S-2) ATSC/SMPTE 310M compliant; 19.4 to 38.8Mbps (VMC-T-H-2

More information

100Gb/s CFP2 Optical Transceiver RTXM

100Gb/s CFP2 Optical Transceiver RTXM 100Gb/s CFP2 Optical Transceiver RTXM290-608 Features Direct LC receptacle optical interface Single +3.3V power supply Hot-pluggable Operating optical data rate up to 112Gbps Transmission distance up to

More information

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications Description The DFB-XXX-BF-10-EC-Fx-Hx-N126 laser modules are designed for fiber optic sensor applications. The narrow linewidth and the option of using polarization maintaining optical fiber made it specially

More information

100Gbps CFP Optical Transceiver RTXM

100Gbps CFP Optical Transceiver RTXM The RTXM290-401 is a hot pluggable 100Gbps small-form-factor transceiver module integrated with the high performance cooled 1310nm EML transmitter and high sensitivity PIN receiver.it is compliant to IEEE802.3ba

More information

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications Description The DFB-XXX-BF-10-EC-Fx-Hx-N126 laser modules are designed for fiber optic sensor applications. The narrow linewidth and the option of using polarization maintaining optical fiber made it specially

More information

100Gb/s CFP2 Optical Transceiver RTXM

100Gb/s CFP2 Optical Transceiver RTXM 100Gb/s CFP2 Optical Transceiver RTXM290-601 Features DirectLC receptacle optical interface Single +3.3V power supply Hot-pluggable Operating optical data rate up to 112Gbps Transmission distance up to

More information

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

Erbium-Doped Fiber Amplifier (EDFA) - MW Series Nanovation s MW series of EDFA products is designed for applications in advanced dense wave division multiplexing (DWDM) systems where high performance and reliability are critical. They are available

More information

FlameGard 5 UV/IR HART

FlameGard 5 UV/IR HART FlameGard 5 UV/IR HART HART Communication Manual The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized

More information

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer Product Brochure & Data Sheet Headquarters: Phoenix, Arizona 20100, N 51st Ave, Suite

More information

FlameGard 5 MSIR HART

FlameGard 5 MSIR HART FlameGard 5 MSIR HART Multi-Spectral Infrared Flame Detector HART Communication with the FlameGard 5 Multi-spectral Infrared Detector The information and technical data disclosed in this document may be

More information

T3/E3 Fiber Optic Line Drivers

T3/E3 Fiber Optic Line Drivers MT618A-ST-R3 January 2004 MT619A-ST-R2 MT620AE-R2 T3/E3 Fiber Optic Line Drivers CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical

More information

LASER DIODE NX8316XC nm FOR LONG HAUL 2.5 Gb/s InGaAsP MQW-DFB LASER DIODE TOSA DESCRIPTION APPLICATION FEATURES

LASER DIODE NX8316XC nm FOR LONG HAUL 2.5 Gb/s InGaAsP MQW-DFB LASER DIODE TOSA DESCRIPTION APPLICATION FEATURES LASER DIODE NX8316XC 1 310 nm FOR LONG HAUL 2.5 Gb/s InGaAsP MQW-DFB LASER DIODE TOSA DESCRIPTION The NX8316XC is a 1 310 nm Multiple Quantum Well (MQW) structured Distributed Feed-Back (DFB) laser diode

More information

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com FL500 Modbus Communication Operating Manual Order No.: 10193214/00 MSAsafety.com 1000 Cranberry Woods Drive Cranberry Township, PA 16066 A Phone 1-800-MSA-2222 Fax 1-800-967-0398 For your local MSA contacts

More information

Product Specification

Product Specification Product Specification M7300CD Variable Gain EDFA, 17 dbm OP, 15-30 db Gain PN: FOA-M7300CD-EVG1C-AA002 Document No.: 1213704 Revision: A00 Date: 01-Apr-14 Customer: General Product Features Variable Gain

More information

HM-4201-RTCM High-Temp Real Time Clock Module

HM-4201-RTCM High-Temp Real Time Clock Module HM-4201-RTCM High-Temp Real Time Clock Module HM-4201-RTCM Product Description & Applications High Temp Real Time Clock/Calendar Module with Build-In 32.768KHz Crystal Oscillator. Timing, Calendar and

More information

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual RC802/804-240B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual Raisecom Technology Co., Ltd. (04/2005) 1. Cautions Please read the following notices carefully before installing and using the device,

More information

FIRERAY 5000 range USER GUIDE

FIRERAY 5000 range USER GUIDE FIRERAY 5000 range USER GUIDE 0044-003-04 IMPORTANT PLEASE NOTE: The beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal.

More information

ETH1000-MKII. User manual

ETH1000-MKII. User manual ETH1000-MKII Gigabit Ethernet Media Converter User manual Rev. 1 1 Nevion Support Nevion Europe P.O. Box 1020 3204 Sandefjord, Norway Support phone 1: +47 33 48 99 97 Support phone 2: +47 90 60 99 99 Nevion

More information

Datasheet: K-22 LO Sensor

Datasheet: K-22 LO Sensor Datasheet: K-22 LO Sensor The K- 22 LO is a CO2 sensor module designed to be built- in into stationary ventilation equipment, such as window vent or duct exhaust actuators, serving as a linear transmitter

More information

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1 Description The DFB-1XXX-BF-XX-CW-Fx-Hx-N127 series of Multi-Quantum Well (MQW) Distributed Feedback (DFB) lasers have been designed specifically to satisfy the requirements of the sensor application.

More information

RS485 MODBUS Module 8AI

RS485 MODBUS Module 8AI Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL Phone: (209) 586-022 (800) 545-022 Fax: (209) 586-026 E-Mail: salessupport@olsontech.com www.olsontech.com OTEB-CO-B (No SNMP) Rev. X7 /7/200 SAFETY WARNINGS

More information

Four channel video link For low cost video transmission

Four channel video link For low cost video transmission User Manual Four channel video link For low cost video transmission CFO First Mile series consist of fi bre optic modems which provide a high quality and losless video transmission for variety of CCTV

More information

OFS IV Optical Fibre System

OFS IV Optical Fibre System OFS IV Optical Fibre System FOR ALL FIBRE OPTIC USERS Fibre optic training has assumed great importance in today s world of widespread fibre optic usage whether in telecommunications or railways, industrial

More information

HM-4201-RTCM High-Temp Real Time Clock Module

HM-4201-RTCM High-Temp Real Time Clock Module HM-4201-RTCM High-Temp Real Time Clock Module HM-4201-RTCM Product Description & Applications High Temp Real Time Clock/Calendar Module with Build-In 32.768KHz Crystal Oscillator. Timing, Calendar and

More information

ECO N DATE DESCRIPTION OF CHANGE CHG

ECO N DATE DESCRIPTION OF CHANGE CHG Model Number: M21E-24-DIN Description: The product is a loop powered device which controls an unsupervised dual pole output channel suitable to manage 24VAC loads. The M21E-24-DIN is micro-controller operated,

More information

Set-Up Procedures. Before You Start

Set-Up Procedures. Before You Start Doc. 2272064, Rev. B Rel. 11/00 5000-ODA Amplifiers Ref. and Install. Manual Set-Up Procedures Before You Start In this section, you will find information about the following procedures: Checking the Optical

More information

Fiber Optics and Liquid Level Sensors Line Guide

Fiber Optics and Liquid Level Sensors Line Guide Fiber Optics and Liquid Level Sensors Line Guide Excellence, through every fiber. Honeywell Sensing and Control (S&C) offers fiber optic sensors manufactured with SERCOS (Serial Real-time Communication

More information

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA HART Field Device Specification Meridian wiredhart 4320 Goldmine Rd. Monroe, NC 28110 USA HART is a registered trademark of the HART Communication Foundation TABLE OF CONTENTS 1. Introduction...5 1.1 Scope...5

More information

Product Specification

Product Specification Product Specification R9300TH Hybrid Raman-EDFA, Dual Raman Pump PN: FOA-R9300TH-HBR3C-AA001 Document No.: 1213710 Revision:A0 0 Date: 18-May-14 Customer: General Product Features Integrated Raman and

More information

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! USER GUIDE English IMPORTANT PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal. Contents

More information

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005) RC801/803/805-480B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual Raisecom Technology Co., Ltd. (04/2005) 1. Cautions Please read the following notices carefully before installing and using the device,

More information

PureGain TM 2600 Variable Gain EDFA for Metropolitan Networks

PureGain TM 2600 Variable Gain EDFA for Metropolitan Networks FEATURES Variable Gain Amplifier with or without Mid-Stage Fully Integrated Control Electronics with State-of-the-Art Transient Suppression Control Three Standard Configurations Mk I: 17 dbm VGA (Variable

More information

ETH1000-D. User manual

ETH1000-D. User manual ETH1000-D Gigabit Ethernet Media Converter with DWDM laser User manual Rev. 2 Nevion Europe P.O. Box 1020, 3204 Sandefjord, Norway Tel: +47 33 48 99 99 Fax: +47 33 48 99 98 www. Nevion Support Nevion Europe

More information

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings Key Features Single and Dual Channel Self Healing Rings for High Reliability

More information

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series MTP-200-D100 Hand-held High Performance OTDR DWDM OTDR with Tunable Laser Series Multi-Function and High Performance OTDR Testing 96 C-band wavelengths Dynamic range up to 38dB Short zone: EDZ 1m, ADZ

More information

Series Digital Controller Instruction Sheet

Series Digital Controller Instruction Sheet 216/3/11 Series Digital Controller Instruction Sheet Thank you very much for purchasing DELTA DTC Series Temperature Controller. Please read this instruction sheet before using your DTC series to ensure

More information

HUM-M2 Humidity Sensor Module Description

HUM-M2 Humidity Sensor Module Description HUM-M2 Humidity Sensor Module Description Humidity Sensor Modules are designed for environment monitoring and controlling in industrial, commercial and other buildings. These transmitters can be used for

More information

OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement

OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement DETECTABLE Gases: Sensor LS-1 R134a Sensor LS-2 R22 Sensor LS-3 CO 2 Sensor LS-4 R134, R404, R407, R410 Sensor LS-5 R134, R404, R407, R410,

More information

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014) User s Fiberprime, Inc. Portable 4-Channel Laser Source Instrument www.fiberprime.com Tel: 1-613-5964030 Email: info@fiberprime.com Fax: 1-613-8289398 Portable 4-Channel Laser Source Instrument in Small

More information

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL ap15_2manual04/22/13 Page 1 4/22/2013 1 Serial Number : Option: OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL Micro Seven, Inc. 1095-K N.E. 25th Hillsboro, OR 97124 U.S.A. phone: 503-693-6982

More information

Technical data sheet TDS0034

Technical data sheet TDS0034 Technical data sheet TDS0034 PREMIER HYDROCARBON INFRARED SENSOR CERTIFIED VERSIONS TYPES MSH-P-HC and MSHia-P-HC Patent Numbers Great Britain GB 2 401 432 & GB 2 403 291 Europe EP 1544603 & EP 1818667-Pending

More information

Analog Input Module IC670ALG630

Analog Input Module IC670ALG630 1 IC670ALG630 The Thermocouple (IC670ALG630) accepts 8 independent thermocouple or millivolt inputs. Module features include: Self calibration Two data acquisition rates based on 50 Hz and 60 Hz line frequencies

More information

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS.  A4741 / Rev.1 DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS User Manual and Menu Map A4741 / Rev.1 www.entes.com.tr ATTENTION -Disconnect all power before connecting the device. -Don t remove

More information

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head 4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head NET DRAFT version 2.1-2008 Pag. 1 4-20mA Cyber - DRAFT version 2.1-2008 Pag.

More information

User Guide OI/FEX100HART EN Rev. A. WaterMaster FEX100 HART Field Device Specification

User Guide OI/FEX100HART EN Rev. A. WaterMaster FEX100 HART Field Device Specification User Guide OI/FEX100HART EN Rev. A WaterMaster FEX100 The Company We are an established world force in the design and manufacture of measurement products for industrial process control, flow measurement,

More information

Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer

Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer ABB MEASUREMENT & ANALYTICS OPERATING INSTRUCTION SUPPLEMENT COM/AZ40/MOD-EN REV. A Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer Communications supplement Measurement made easy Oxygen

More information

OVEN INDUSTRIES, INC.

OVEN INDUSTRIES, INC. OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and

More information

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG. LD-64 Profibus

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG. LD-64 Profibus LD-64 Profibus INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG Galvanic Isolation 6073-2031 Transient Protection Balanced Transmission CE Approved Westermo Teleindustri AB 2001 REV. B Fiberoptiskt

More information

PREMIER PLATINUM INFRARED TRIPLE RANGE HYDROCARBON SENSOR Exd Certified versions *** Available in EN50271 / SIL1 Certified versions ***

PREMIER PLATINUM INFRARED TRIPLE RANGE HYDROCARBON SENSOR Exd Certified versions *** Available in EN50271 / SIL1 Certified versions *** Technical data sheet TDS0118 PREMIER PLATINUM INFRARED TRIPLE RANGE HYDROCARBON SENSOR Exd Certified versions *** Available in EN50271 / SIL1 Certified versions *** SIL1 Non - SIL MSH-PS/HC MSHia-PS/HC

More information

G155PU001S. Pigtailed 14-PIN DIL Laser Diode with TEC. FLMS Min. Typ. Max.

G155PU001S. Pigtailed 14-PIN DIL Laser Diode with TEC. FLMS Min. Typ. Max. G155PU001S TECHNICAL DATA Pigtailed 14-PIN DIL Laser Diode with TEC Features 1 mw 1550 nm MQW Laser Diode Module with cooler 14pin DIL package with single mode fiber output Applications Optical Communication

More information

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions ***

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions *** Technical data sheet TDS0149 LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions *** SIL1 MSH2-LS/HC/CO2 MSH2ia-LS/HC/CO2

More information

200 SERIES ADVANCED PHOTO/THERMAL/IR DETECTOR PRODUCT SPECIFICATION

200 SERIES ADVANCED PHOTO/THERMAL/IR DETECTOR PRODUCT SPECIFICATION GENERAL DESCRIPTION This product is the photo/thermal/ir variant of 2 Series Advanced, the redesigned 2 Series all SMD adopting the new chamber and a new style of covers. It works with the 2 Series extended

More information

Database for CTS6000 MODBUS

Database for CTS6000 MODBUS Database for CTS6000 MODBUS Valid for: LONcard SW1.7.4B, Variable List V2.02 Version 1.08-4, 01-05-2016 Contents Contents... 2 1. Installation... 3 1.1. Installation and operating instructions... 3 2.

More information

4 Channel Contact Closure SFP DIN Fiber Link System

4 Channel Contact Closure SFP DIN Fiber Link System USER GUIDE The leader in rugged fiber optic technology. U- 07A-0707 Channel Contact Closure DIN Fiber Link System Installation and Configuration Information Description The system provides transmission

More information

NIDS Dust sensor ED-N-DS-1408

NIDS Dust sensor ED-N-DS-1408 SPECIFICATION (Tentative) Product Name: Dust Sensor(High Sensitivity) Model No. : SM-PWM-01A-HS SMART dust sensor for air purifier SM-PWM-01A-HS Description SM-PWM-01A-HS is a dust sensor that detects

More information

Key Features. General Description

Key Features. General Description Key Features SIL2 rated, for certified dependability (fail-safe detection) Special coating for electronics protection in harsh environments Dedicated temperature range, for maximum detection accuracy Individual

More information

CM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications

CM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications Cooled 980nm Pump Laser Module Features High output power, >1.0W kink free Fiber Bragg grating stabilization for wavelength locking over the entire operating conditions Hermetically sealed 10pin mini-butterfly

More information

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-64F

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-64F LD-64F INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG 6073-2011 Westermo Teleindustri AB 2001 REV. C Galvanic Isolation Transient Protection Balanced Transmission CE Approved Redundant linjedelare

More information

BTI7800 Series Alarm and Troubleshooting Guide

BTI7800 Series Alarm and Troubleshooting Guide BTI7800 Series Alarm and Troubleshooting Guide Juniper Networks, Inc. 1133 Innovation Way Sunnyvale, CA 94089 USA Part Number: Document Version: Published: Type: tel: 408-745-2000 BT8A78PD0021 01 November

More information

IFS SFP Tranceivers User Manual

IFS SFP Tranceivers User Manual IFS SFP Tranceivers User Manual P/N 1069181 REV 02.00 ISS 22AUG11 Copyright Trademarks and patents Manufacturer 2011 UTC Fire & Security. All rights reserved. Interlogix, IFS SFP Tranceivers Brand and

More information

Fiber Optical Multiplexer

Fiber Optical Multiplexer Fiber Optical Multiplexer 8x E1, 1x Fast Ethernet, Hotline, 1x Fiber optic XL-FMUX4E1 User s Manual Thank you for using XtendLan s products. This manual will show you how to install and use this product.

More information

Technical Data Sheet 5mm Infrared LED, T-1

Technical Data Sheet 5mm Infrared LED, T-1 Technical Data Sheet 5mm Infrared LED, T-1 Features High reliability 2.54mm lead spacing Low forward voltage Good spectral matching to Si photodetector Pb free The product itself will remain within RoHS

More information

760nm Single mode VCSEL with Peltier Element and Thermistor in TO510

760nm Single mode VCSEL with Peltier Element and Thermistor in TO510 760nm Single mode VCSEL with Peltier Element and Thermistor in TO510 APC11010108xy Features: Laser Enterprise s 760nm VCSELs are designed to meet the requirements for the optical measurement of oxygen

More information

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM DS 96/48 P Digital indicator Short manual 41/33-89 EN Rev. 00 A1 A2 DIM E 1 Safety instructions Correct and safe operation of the apparatus calls for expert installation and meticulous maintenance. This

More information

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet.

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet. Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) LS-1310/1550 Service Information Sheet Introduction This Service Information Sheet provides the following service information

More information

USER MANUAL FOR OPERATING SYSTEM

USER MANUAL FOR OPERATING SYSTEM P2262 ALARM PANEL USER MANUAL FOR OPERATING SYSTEM 21765-07 September 1999 Associated Controls (Aust) PTY. LTD. 29 Smith Street, Hillsdale, NSW, 2036. PH (02) 9311 3255, FAX (02) 9311 3779 Page 1 of 177

More information

SMART dust sensor for air purifier Description SM-ND-02A SM-ND-02A is a dust sensor that detects the dust particle concentration in air by using optic

SMART dust sensor for air purifier Description SM-ND-02A SM-ND-02A is a dust sensor that detects the dust particle concentration in air by using optic SPECIFICATION Product Name: Dust Sensor Model No. : SM-ND-02A ( Tentative ) SMART dust sensor for air purifier Description SM-ND-02A SM-ND-02A is a dust sensor that detects the dust particle concentration

More information

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

Optical Return Loss Measurement by Gregory Lietaert, Product Manager White Paper Optical Return Loss Measurement by Gregory Lietaert, Product Manager Introduction With the increasing frequency of high-speed transmission systems and DWDM deployment, optical return loss (ORL)

More information

HFX Fiber Optic Component 50 Mbps, 650 nm LED

HFX Fiber Optic Component 50 Mbps, 650 nm LED HFX7000-200 Fiber Optic Component 50 Mbps, 650 nm LED DESCRIPTION The HFX7000-200 is a 50 Mbps LED designed to meet data transmission requirements in factory or office automation. The 650 nm wavelength

More information

SD Series Optoschmitt Detector, TO-46 Metal Can Package

SD Series Optoschmitt Detector, TO-46 Metal Can Package Representative photograph, actual product appearance may vary. Due to regional agency approval requirements, some products may not be available in your area. Please contact your regional Honeywell office

More information

Dust sensor SM-PWM-01A SPECIFICATION. Product Name: Dust Sensor Model No. : SM-PWM-01A 1 / 12

Dust sensor SM-PWM-01A SPECIFICATION. Product Name: Dust Sensor Model No. : SM-PWM-01A 1 / 12 SPECIFICATION Product Name: Dust Sensor Model No. : SM-PWM-01A 1 / 12 SM-PWM-01A SMART dust sensor for home appliance Description SM-PWM-01A is a dust sensor that detects the dust particle concentration

More information

G4 Pulsed Fiber Laser

G4 Pulsed Fiber Laser G4 Pulsed Fiber Laser OEM Safety and System Integration Manual Module types C1 and C2 Module type C1 - fitted with IBeam1 delivery optic Module type C2 - fitted with IBeam2 delivery optic 1 1 Preface Definition

More information

8-Channel Thermocouple Input Ethernet Data Acquisition Module

8-Channel Thermocouple Input Ethernet Data Acquisition Module 8-Channel Thermocouple Input Ethernet Data Acquisition Module OM-NET-TC TM Eight 24-Bit Differential Thermocouple Inputs with Thermocouple Channel-to-Host Isolation 4 Samples/Sec Channel Maximum Sample

More information

I R T Electronics Pty Ltd A.B.N. 000 8 7 6 Hotham Parade, ARTARMON N.S.W. 06 AUSTRALIA National: Phone: (0) 99 7 Fax: (0) 99 79 International: +6 99 7 +6 99 79 Email: sales@irtelectronics.com Web: www.irtelectronics.com

More information

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option SM3000 Videographic Recorder User Guide (RTU) Communications Option ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow

More information

F 2 MC-8FX FAMILY MB95200 SERIES SMOKE DETECTOR DEMO REFERENCE SOLUTION 8-BITMICROCONTROLLER APPLICATION NOTE

F 2 MC-8FX FAMILY MB95200 SERIES SMOKE DETECTOR DEMO REFERENCE SOLUTION 8-BITMICROCONTROLLER APPLICATION NOTE Fujitsu Semiconductor (Shanghai) Co., Ltd. Application Note MCU-AN- 500054-E-10 F 2 MC-8FX FAMILY 8-BITMICROCONTROLLER MB95200 SERIES SMOKE DETECTOR DEMO REFERENCE SOLUTION APPLICATION NOTE Revision History

More information

ACCURATE ELECTRONICS INC

ACCURATE ELECTRONICS INC ACCURATE ELECTRONICS INC Page 1 of 7 Model 108078 2 Sept 09 WWW.ACCURATE.ORG PO BOX 1654 97075-1654 8687 SW Hall Blvd 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 Practice Section 108078 Rev A

More information

TEMPERATURE CONTROL MODULE MODEL R3-TC2

TEMPERATURE CONTROL MODULE MODEL R3-TC2 INSTRUCTION MANUAL R3-TC2 TEMPERATURE CONTROL MODULE MODEL R3-TC2 CONTENTS BEFORE USE... 2 POINTS OF CAUTION... 2 COMPONENT IDENTIFICATION... 2 INSTALLATION... 2 EXTERNAL DIMENSIONS unit: mm (inch)...

More information

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV CyCLO User Guide Version 2.00 19 th December 2017 REV 2.00 1 Contents 1. Hardware... 3 1.1. Introduction... 3 1.2. Electrical Specification... 3 1.3. Board Overview... 4 1.4. Electrical Installation...

More information

MT-RJ Optical Fiber System Field Testing

MT-RJ Optical Fiber System Field Testing MT-RJ Optical Fiber System Field Testing Table of Contents INTRODUCTION... 3 TEST JUMPERS... 4 LAUNCH CONDITIONS... 4 MT-RJ TEST KITS... 5 MT-RJ SYSTEM TESTING: Fixed transmit and receive (SC or ST-style)

More information

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min

More information

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features: GE Oil & Gas RPS/DPS 8000 High Accuracy Resonant Pressure Sensor Since 1972, Druck has manufactured precision pressure sensors with a capability to meet critical applications in industrial, aerospace,

More information

FIS SMART SENSOR U (Draft 1) June 25, 2001

FIS SMART SENSOR U (Draft 1) June 25, 2001 FIS200-0 SPECIFICATIONS (Draft ) MODEL PARTS NAME SPECIFICATION No. DATE OF ISSUE FIS200-0 SMART SENSOR U-004-0 (Draft ) June 25, 200 Distribution Number of copies Date Customer Distributor FIS Signatures

More information

Advance Optima Module Magnos 17

Advance Optima Module Magnos 17 Advance Optima Module Magnos 17 Service Manual 43/24-1002-0 EN Table of Contents Page Chapter 1: Description of functions 1-1 Chapter 2: Module variants and components 2-1 Chapter 3: Analyzer variants

More information

Smoke Detector Demo Reference Solution

Smoke Detector Demo Reference Solution Fujitsu Microelectronics (Shanghai) Co., Ltd. Application Note MCU-AN- 500054-E-10 F 2 MC-8FX FAMILY 8-BITMICROCONTROLLER MB95200 SERIES Smoke Detector Demo Reference Solution APPLICATION NOTE Smoke Detector

More information

I R T Electronics Pty Ltd A.B.N. 5 000 8 575 6 Hotham Parade, ARTARMON N.S.W. 06 AUSTRALIA National: Phone: (0) 99 7 Fax: (0) 99 79 International: +6 99 7 +6 99 79 Email: sales@irtelectronics.com Web:

More information

DHM5150 Human Motion Sensor Module User Manual

DHM5150 Human Motion Sensor Module User Manual DHM5150 Human Motion Sensor Module User Manual Version: 1.0.2 February 2005 Table of Contents I. Introduction 2 II. Operations 2 II.1. Theory of Operation 2 II.2. Running as Part of WiRobot System 3 II.3.

More information

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Process & TeMPerATUre UniversAl input DigiTAl MeTers Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min

More information

Module Features are-configurable, no module jumpers to set

Module Features are-configurable, no module jumpers to set December 2011 PACSystems* RX3i Isolated Thermocouple Input Module, 6 Channels, IC695ALG306 Isolated Thermocouple Input Module, 12 Channels, IC695ALG312 Isolated Thermocouple Input module IC695ALG306 provides

More information

SMART Dust Sensor. Amphenol Advanced Sensors SM-PWM-01C. Application Note. Features

SMART Dust Sensor. Amphenol Advanced Sensors SM-PWM-01C. Application Note. Features Application Note SMART Dust Sensor SM-PWM-01C SM-PWM-01C dust sensor detects dust particle concentration in air by using an optical sensing method. An infrared light emitting diode (IR LED) and a photo-sensor

More information

M15-GSL12P30 M15-GSL12P30S Heat Spy Infrared Thermometer User Manual

M15-GSL12P30 M15-GSL12P30S Heat Spy Infrared Thermometer User Manual M15-GSL12P30 M15-GSL12P30S Heat Spy Infrared Thermometer User Manual WD1097 Rev B 01/29/13 Wahl Instruments, Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free 800-421-2853 Phone 828-658-3131

More information