DISTRIBUTOR GUIDE FOR SELLING QUALITY TO CONTRACTORS

Size: px
Start display at page:

Download "DISTRIBUTOR GUIDE FOR SELLING QUALITY TO CONTRACTORS"

Transcription

1 DISTRIBUTOR GUIDE FOR SELLING QUALITY TO CONTRACTORS THERMAL BUILDING SOLUTIONS

2 2 2THERMAL PENTAIR BUILDING SOLUTIONS

3 table of contents Why Choose Raychem 4 Roof and Gutter De-Icing Systems 6 Pipe Freeze Protection Systems 10 Surface Snow Melting Systems 14 Nuheat Floor Heating Systems 16 Winter Safety Product Chart 18 Roof & Gutter De-Icing Pipe Freeze Protection Surface Snow Melting Floor Heating FLOORHEATING 3 3

4 Why choose Raychem? Raychem self-regulating heat-tracing cables outperform other self-regulating cables Other heat-tracing products may look like ours but don t be fooled. Our quality-driven manufacturing processes, combined with years of manufacturing experience allows Pentair to provide the most reliable products just see the good examples that represent the Raychem brand versus the poor examples that represent some competitive offerings. Rely on Raychem self-regulating heat-tracing systems for your heat-tracing needs. 1. Even Heat Distribution The even dispersion of conductive particles in the core of all Raychem brand selfregulating heating cables means uniform heat distribution internally and along the entire length of the heating cable. This uniform distribution of carbon particles prevents localized internal overheating and maximizes the life of the cable. Good dispersion Poor dispersion 2. No Cold Spots! No Hot Spots! No Burnouts! All Raychem brand self-regulating heating cables have good contact between the conductive core and the parallel bus wires eliminating localized hot or cold spots and premature cable failure. This prevents under heating or overheating and increases reliability. Good contact Poor contact 3. Efficient Heat Transfer The tight fit of the insulating jacket on all Raychem self-regulating heating cables maximizes the transfer of heat from cable to pipe, saving energy while eliminating premature aging of the cable. Tight jacket Loose jacket Raychem Self-Regulating Cables - Made in America 4 4THERMAL PENTAIR BUILDING SOLUTIONS

5 Raychem self-regulating heat-tracing cables outperform constant wattage cables This is the typical construction of constant wattage cable, including those found at DIY Box Stores. Constant Wattage Outside 1. Outside Raychem WinterGard Self-Regulating Cable Rugged cable specifically designed for easy installation and long life. Cable is crossedlinked to enhance its UV resistance and increase its flexibility in low temperatures. Writing on the outer jacket provides product information to the installer and the end user. Constant Wattage Cable No writing or reference info on outside of cable. Inside 2. Inside Raychem WinterGard Self-Regulating Cable Dense ground braid offers additional protection. Inner, thick crosslinked polyolefin insulating jacket. Constant Wattage Cable Ground weave falls away easily. Heating 3. Heating Raychem WinterGard Self-Regulating Cable A pair of 16 AWG bus wires encased in a solid polymer heating core. If a part of the core gets damaged, the rest of the heater still works. If the cable gets cut, it is repairable. Cable is repairable using readily available Raychem Tee or Splice kits. Constant Wattage Cable Extremely thin, resistive filament coiled around a nylon thread, protected by a plastic insulating jacket. This style of cable construction is extremely susceptible to field damage. Close up of heating filament. If this breaks, the customer loses the entire heater from beginning to end. Non-repairable FLOORHEATING 5 5

6 solutions to make a home winter safe ROOF & GUTTER DE-ICING Raychem roof & gutter de-icing systems protect roofs and gutters from ice dams, heavy snow build-up, and icicles. The heating cable creates a continuous path for melted ice and snow to drain. Our product range allows you to choose the right solution for your application and budget from our basic, reliable preassembled plug-in kit, to solutions with energy-saving controllers, and our aesthetically elegant solution. FROSTGUARD Preassembled Plug-In Heating Cable System NEW! Preassembled self-regulating heating cable with 6-ft cold lead and lighted plug for short standard or standing seam roof & gutter de-icing applications on porches and overhangs. Voltage: 120 V in lengths of 6, 12, 18, 24, 36, 50, 75 & 100 feet Components: H913/H914 roof clips, H915 downspout hanger GARDIAN Preassembled Plug-In Heating Cable System Preassembled self-regulating heating cable with 2.5-ft cold lead and plug for short standard or standing seam roof & gutter de-icing applications on porches and overhangs. Voltage: 120 V in lengths of 6, 12, 18, 24, 50, 75 & 100 feet Components: H913/H914 roof clips, H915 downspout hanger WINTERGARD WET Pre-Packaged in Standard Spool Sizes and Cut-to-Length Heating Cable System Self-regulating heating cable that can be cut and spliced to fit the layout of any standard or standing seam roof line with gutters up to 6 inches wide. Choosing the H908 Plug-in cord (for 120 V only) eliminates the need to hardwire, thus reduces installation costs. Voltage: 120 V or 240 V Control and sensor options: PD-Pro and GF-Pro, LCD-8, CIT-1, GIT-1 Components: H900 hardwire or H908 plug-in power connection kit; H913/H914 roof clips, H915 downspout hanger, H910 Splice/Tee kit RIM (ROOF ICE MELT) Premiere Custom Roof Ice Melt Panel System The Roof Ice Melt (RIM) System is our premiere, highest performing, aesthetically elegant roof & gutter de-icing solution ideal for new construction or renovation of residential or commercial buildings, for ALL snow load areas. The system consists of metallic panels that embed selfregulating heat tracing cable to provide high power output. The RIM system includes panels specifically designed for eaves, valleys, channels, rakes, and flat roof sections. Voltage: 120 V or 240 V Roof & Gutter Controller Selection Details (RIM-specific controllers not included in the table below) GOOD BETTER BEST EC-TS LCD-8 PD-PRO & CIT-1 / GIT-1 Electronic thermostat Ambient or line sensing Adjustable set point of 30 F to 110 F 25 thermistor sensor 30 A at V Moisture/temperature sensing controller Aerial mounted sensor Up to 5-hour hold time (adjustable) Compatible with external contactors 16 A at 120 V Temperature and moisture sensing controller Works w/ CIT-1 aerial and/or GIT-1 gutter sensors Up to 8-hour hold time (adjustable) LED lights to indicate power and heat cycle Compatible with external contactors 30 A at V GF-PRO & CIT-1 / GIT-1 Temperature and moisture sensing controller Built-in GFEP protection Works w/ CIT-1 aerial and/or GIT-1 gutter sensors Up to 8-hour hold time (adjustable) LED lights to indicate power and heat cycle 30 A at V 6 6THERMAL PENTAIR BUILDING SOLUTIONS For complete specifications and other design assistance, refer to the appropriate data sheets and application design guides available on our websites

7 Raychem self-regulating heating cables outperform constant wattage cables CONSTANT WATTAGE HEATING CABLE RAYCHEM WINTERGARD SELF-REG HEATING CABLE Roof & Gutter De-Icing DESIGN Contractor Grade Construction built to withstand the construction site. Heavy-duty polyolefin outer jacket, dense ground braid, thick polyolefin inner jacket, 16 awg bus wires surrounded by a solid polymer heating core Impact Resistant No Yes No Yes Cut To Length No Yes Can be Overlapped Without causing Hotspots No Yes Repairable No Yes HEAT OUTPUT Regulates Right Amount of Heat Output - more heat in ice and snow, reduced heat when dry Saves money No Yes No Yes CONNECTIONS Tee Available No Yes Splice Available No Yes ROOF TYPE COMPATIBILITY Asphalt Shingles Yes Yes Tile No Yes Wood Shakes No Yes Metal No Yes Rubber No Yes Flat roofs No Yes SOLD THROUGH Sold through Box Stores Yes No FLOORHEATING 7 7

8 Text text text text text text text text text text text text text Roof and Gutter De-Icing Heat Tracing System Select Cable Power Connection Tee s/splices Roof Clips Downspout Hangers Controls Description Cat # FrostGuard Preassembled Lighted Plug-In Heating Cable System 120 V FG1 Standard Package Number of Packages Required 120 V: 6, 12, 18, 24, 36, 50, 75, 100 Feet 6-ft cold lead and lighted plug Gardian Preassembled Plug-In Heating Cable System 120 V W V: 6, 12, 18, 24, 50, 75, 100 Feet 2.5-ft cold lead and plug WinterGard Wet 120 V H612 Reel Lengths: 50, 250, 500, 1000 Truck Pak: includes 100 cable, (2) H900, (1) H910, (1) H903 WinterGard Wet V H622 Reel Lengths: 50, 250, 500, 1000 Truck Pak: includes 100 cable, (2) H900, (1) H910, (1) H903 Hard-wired power connection for WinterGard Wet systems. Includes gel-filled push-on end seal. Junction box not included. Plug-in 120 V, 15 A power connection for WinterGard Wet. Built-in light and 27-mA GFPD. Includes gel-filled end seal. H900 1/pkg 1 kit for each circuit of WinterGard Wet heating cable. Refer to Design Guide for maximum WinterGard Wet circuit lengths for hard-wired systems H908 1/pkg 1 kit for every 125 of 120 V WinterGard Wet cable. If used, H900 not required. Waterproof splice / tee kit. Includes gelfilled push-on end seal. H910 1/pkg 1 kit for each splice or tee Gel-filled push-on end seal H912 2/pkg This kit contains two extra end seals. Note: End seals are provided in the H900, H908 and H910 accessory kits. Roof clip H913 10/pkg 1 pkg per 7 of roof edge for serpentine layout. H914 50/pkg 1 box per 35 of roof edge for serpentine layout. Downspout hanger bracket H915 1/pkg 1 hanger per cable in downspout or as required for mechanical protection Length of heating cable = A + B + C + D A Roof edge length (ft) x Feet of heating cable per foot of roof edge B Roof edge (ft) x.5** C Total gutter length (ft) D Total downspout length (ft) = Total Heating Cable Length * Gutter required ** Roof extension: This length allows the heating cable to extend into the gutter to provide a continuous drain path, or where no gutters are present, extends beyond the roof edge to form a drip loop. Note: Pentair Thermal Management recommends a gutter and downspouts to provide a continuous path for melted water. Length of Cable Per Foot of Roof Edge (ft) Overhang (in) Standard Roof Standing Seam Metal Roof 18 inch Seam 24 inch Seam None* in in in Start-up Temperature, Maximum Circuit Length H612 H612 H622 H622 Circuit breaker rating (A) 0 F 32 F 0 F 32 F THERMAL PENTAIR BUILDING SOLUTIONS

9 Contractor: Tear here. Offer the left side to the homeowner / building owner. the worksheet to your Raychem Sales Rep to get a complete Bill of Materials and quote! 2016 Pentair. H /16 ROOF & GUTTER SYSTEM ESTIMATE FORM 1. Building Type & Conditions: (check all that apply) 2. Area Name: House Small shop / strip mall High-rise residential /multi-use bldg. Commercial building New Construction Retrofit Annual Snow Fall less than 100 inches more than 100 inches 3. Type of Roof: Sloped Roof Shingle Sloped Roof Shingle Sloped Roof Shingle Sloped Roof Shingle Metal RoofSeams Metal RoofSeams Metal RoofSeams Metal RoofSeams Don't Trace Roof Don't Trace Roof Don't Trace Roof Don't Trace Roof 4. Roof Pitch: Less than 3/12 Equal to or more than 3/12 Less than 3/12 Equal to or more than 3/12 Less than 3/12 Equal to or more than 3/12 Less than 3/12 Equal to or more than 3/12 5. Length of Roof Edge: feet feet feet feet 6. Eave Overhang Distance: 0" 12" 24" 36" (other) inches (other) inches (other) inches (other) inches 7. Gutters: Total Length: feet Total Length: feet Total Length: feet Total Length: feet Depth: inches Depth: inches Depth: inches Depth: inches Width: Inches Width: Inches Width: Inches Width: Inches No Gutters No Gutters No Gutters No Gutters 8. Downspouts: Number of Downspouts: Number of Downspouts: Number of Downspouts: Number of Downspouts: Average Downspout Length: ft Average Downspout Length: ft Average Downspout Length: ft Average Downspout Length: ft Single Run in Downspout Single Run in Downspout Single Run in Downspout Single Run in Downspout Loop Run in Downspout Loop Run in Downspout Loop Run in Downspout Loop Run in Downspout No Preference No Preference No Preference No Preference 9. Valleys: Number of Valleys: Number of Valleys: Number of Valleys: Number of Valleys: Average Valley Length: ft Average Valley Length: ft Average Valley Length: ft Average Valley Length: ft 10. Voltage: 120 V 208 V 240 V 277 V 120 V 208 V 240 V 277 V 120 V 208 V 240 V 277 V 120 V 208 V 240 V 277 V 11. Circuit Breaker Size: 15 A 20 A 30 A 15 A 20 A 30 A 15 A 20 A 30 A 15 A 20 A 30 A 12. RIM Cover Panel: Kynar Painted Aluminum Kynar Painted Aluminum Kynar Painted Aluminum Kynar Painted Aluminum Copper Copper Copper Copper 13. Controllers: Ambient Temperature Only Ambient Temperature Only Ambient Temperature Only Ambient Temperature Only 14. Notes: 15. Customer name: Company: Phone: completed form to your Pentair Sales Rep for a complete Bill of Materials and quote! Need Quote For: HEATING CABLE SYSTEM RIM CONCEALED SYSTEM BOTH CHECK OUT OUR ONLINE ROOF AND GUTTER DE-ICING DESIGN TOOL at by selecting the Commercial or Residential segment -> Resources and click on the Roof & Gutter De-Icing Calculator design tool. Ambient & RIM Panel Temperature (HECS) Ambient & RIM Panel Temperature (HECS) Ambient & RIM Panel Temperature (HECS) Ambient & RIM Panel Temperature (HECS) Gutter Moisture & Temperature Sensor Gutter Moisture & Temperature Sensor Gutter Moisture & Temperature Sensor Gutter Moisture & Temperature Sensor Roof & Gutter De-Icing Project name: Project location: BUSINESS CARD

10 solutions to make a home winter safe PIPE FREEZE PROTECTION Raychem pipe freeze protection systems are flexible and easy to attach to the exterior of the pipe to keep pipes from freezing, bursting, and causing water damage. Our product range allows you to choose the right solution for your application and budget from a simple preassembled plug-in kit to one that offers energy-saving control and sensing options. FROSTGUARD Preassembled Plug-In Heating Cable System NEW! Preassembled self-regulating heating cable with 6-ft cold lead and lighted plug for small piping up to 2-1/2 inches in diameter in dry or wet locations. Voltage: 120 V with plug, in lengths of 6, 12, 18, 24, 36, 50, 75 & 100 feet; 240 V with cold lead only, in lengths of 6, 12, 18 & 24 feet Control options: TC-3 thermostatically controlled outlet for 120 V only Components: H903 application tape GARDIAN Preassembled Plug-In Heating Cable System Preassembled self-regulating heating cable with 2.5-ft cold lead and plug for small piping up to 2-1/2 inches in diameter in dry or wet locations. Voltage: 120 V with plug, in lengths of 6, 12, 18, 24, 50, 75 & 100 feet; 240 V with cold lead only, in lengths of 6, 12, 18 & 24 feet Control options: TC-3 thermostatically controlled outlet for 120 V only Components: H903 application tape WINTERGARD SERIES Pre-Packaged in Standard Spool Sizes and Cut-to-Length Heating Cable System Self-regulating heating cable for piping up to 6 inches in diameter for dry and wet locations. The WinterGard series of products includes WinterGard, WinterGard Plus and WinterGard Wet. See the chart on pages 6-7 for more details on each. Voltage: 120 V or 240 V Control options: AMC-F5, AMC-1A, EC-TS, SST-2 Components: H900 hardwire or H908 plug-in power connection kit; H903 application tape; H910 Splice/Tee kit Pipe Freeze Thermostat Selection Details GOOD BETTER BEST TC-3 AMC-F5 EC-TS Thermostatically controlled outlet Mechanical thermostat Ambient or line sensing Fixed set point of 40 F (nonadjustable) 3 bulb and capillary sensor 22 A at 125/250/480 V AMC-1A Mechanical thermostat Ambient sensing Adjustable set point of 15 F to 140 F 22 A at 125/250/480 V Electronic thermostat Ambient or line sensing Adjustable set point of 30 F to 110 F 25 thermistor sensor 30 A at V SST-2 Electronic thermostat Built-in GFEP protection Ambient or line sensing Fixed set point of 40 F (nonadjustable) 20' probe (extendable up to 2000 ft) 30 A at V 10 10THERMAL PENTAIR BUILDING SOLUTIONS For complete specifications and other design assistance, refer to the appropriate data sheets and application design guides available on our websites

11 Raychem self-regulating heating cables outperform constant wattage cables DESIGN Contractor Grade Construction built to withstand the construction site. Heavy-duty polyolefin outer jacket, dense ground braid, thick polyolefin inner jacket, 16 awg bus wires surrounded by a solid polymer heating core CONSTANT WATTAGE HEATING CABLE Impact Resistant No Yes No RAYCHEM WINTERGARD SELF-REG HEATING CABLE Yes Pipe Freeze Protection HEAT OUTPUT Cut To Length No Yes Can be Overlapped Without causing Hotspots No Yes Repairable No Yes Regulates Right Amount of Heat Output - more heat in ice and snow, reduced heat when dry Saves money No Yes No Yes CONNECTIONS Tee Available No Yes Splice Available No Yes PIPE TYPE COMPATIBILITY Plastic drain Lines No Yes Fuel Lines No Yes Hoses No Yes WARRANTY 1 yr 2-10 yrs SOLD THROUGH Sold through Box Stores Yes No FLOORHEATING 11 11

12 Text text text text text text text text text text text text text Pipe Freeze Protection Heat Tracing System Select Cable Power Connection Tee s/splices Tape and Labels Controls Description Cat # FrostGuard Preassembled Lighted Plug-In Heating Cable System 120/208/240 V FG1 FG2 Standard Package Number of Packages Required 120 V: 6, 12, 18, 24, 36, 50, 75, 100 Feet; 6-ft cold lead and lighted plug V: 6, 12, 18, 24 Feet; 6-ft cold lead Gardian Preassembled Plug-In Heating Cable System 120/208/240 V W51 W V: 6, 12, 18, 24, 50, 75, 100 Feet; 2.5-ft cold lead and plug V: 6, 12, 18, 24 Feet; 2.5-ft cold lead WinterGard 120 V H311 Reel Lengths: 100', 250' Truck Pak: includes 100 cable, (2) H900, (1) H910, (1) H903 WinterGard Plus 120 V H611 Reel Lengths: 50, 100', 250 Truck Pak: includes 100 cable, (2) H900, (1) H910, (1) H903 WinterGard Plus 240 V H621 Reel Lengths: 50, 100', 250 Truck Pak: includes 100 cable, (2) H900, (1) H910, (1) H903 WinterGard Wet 120 V H612 Reel Lengths: 50, 100', 250, 500, 1000 Truck Pak: includes 100 cable, (2) H900, (1) H910, (1) H903 WinterGard Wet V H622 Reel Lengths: 50, 100', 250, 500, 1000 Truck Pak: includes 100 cable, (2) H900, (1) H910, (1) H903 Hard-wired power connection for Winter- Gard systems. Includes gel-filled push-on end seal. Junction box not included. Plug-in 120 V, 15 A power connection for WinterGard Wet. Built-in light and 27-mA GFPD. Includes gel-filled end seal. Waterproof splice / tee kit. Includes gelfilled push-on end seal. H900 1/pkg 1 kit for each circuit of heating cable. Refer to Design Guide for maximum WinterGard circuit lengths for hardwired systems H908 1/pkg 1 kit for every 125 of 120 V heating cable. If used, H900 not required. H910 1/pkg 1 kit for each splice or tee Gel-filled push-on end seal. H912 2/pkg This kit contain two extra end seals. Note: end seals are provided in the H900, H908 and H910 accessory kits. Fiberglass Application Tape and Electric Traced labels. Included in TruckPak Kit. H903 1 roll 10 labels Used to attach heating cable to pipe. Includes 1 roll (66 ft) of tape and 10 warning labels Length of heating cable = A + B + C + D + E A Pipe length x spiral ratio* B 4 ft x number of valves C 1 ft x number of Power connections D 2 ft x number of Splice connections E 3 ft x number of Tee connections = Total Heating Cable Length Number of Power Connections = A / B A Total heating cable length (ft) B Maximum Circuit Length = Power Connections (Round up) Pipe Size, Spiral Ratio Adjustment Chart Min. Ambient Temp: 20 F Insulation Thickness 1½ 2 2½ Metal Pipes 1" " 1.1 2" PVC Pipes 1" " " 1.4 One run of H612 or H622 unless noted Start-up Temperature, Maximum Circuit Length Circuit breaker H611/H612 H611/H612 H621/H622 H621/H622 rating (A) 0 F 40 F 0 F 40 F THERMAL PENTAIR BUILDING SOLUTIONS

13 PIPE FREEZE PROTECTION SYSTEM ESTIMATE FORM completed form to your Pentair Sales Rep for a complete Bill of Materials and quote! CHECK OUT XL-ERATE, OUR ONLINE PIPE TRACE DESIGN TOOL at by selecting the Commercial or Residential segment -> Resources and click on the XL-ERATE design tool. Contractor: Tear here. Offer the left side to the homeowner / building owner. the worksheet to your Raychem Sales Rep to get a complete Bill of Materials and quote! 2016 Pentair. H /16 1. Building Type: House Small shop / strip mall High-rise residential /multi-use bldg. Commercial building 2. Line Name: 3. Application: Water Lines Water Lines Water Lines Water Lines Fire Protection Lines Fire Protection Lines Fire Protection Lines Fire Protection Lines Greasy Waste Lines Greasy Waste Lines Greasy Waste Lines Greasy Waste Lines Fuel Oil Lines Fuel Oil Lines Fuel Oil Lines Fuel Oil Lines Other: Other: Other: Other: 4. Location: Above Ground Below Ground Above Ground Below Ground Above Ground Below Ground Above Ground Below Ground 5. Minimum Ambient: : (indoor) : (indoor) : (indoor) : (indoor) 6. Maintain Temp ( F): ( F) ( F) ( F) ( F) 7. Max Pipe Temp ( F): Other Other Other Other 8. Voltage: 120 V 208 V 240 V 277 V 120 V 208 V 240 V 277 V 120 V 208 V 240 V 277 V 120 V 208 V 240 V 277 V 9. Circuit Breaker Size: 15 A 20 A 30 A 40 A 15 A 20 A 30 A 40 A 15 A 20 A 30 A 40 A 15 A 20 A 30 A 40 A 10. Length of Pipe: feet feet feet feet 11. Pipe Diameter: inches inches inches inches 12. Pipe Material: Metal Plastic Metal Plastic Metal Plastic Metal Plastic 13. Number of Valves: 14. Supports Outside Insulation? Yes No Yes No Yes No Yes No 15. Number of Flanges: 16. Insulation Type: Fiberglass Fiberglass Fiberglass Fiberglass CalSil CalSil CalSil CalSil Cellular Glass Cellular Glass Cellular Glass Cellular Glass Rigid Cellular Urethane Rigid Cellular Urethane Rigid Cellular Urethane Rigid Cellular Urethane Foamed Elastomer Foamed Elastomer Foamed Elastomer Foamed Elastomer Mineral Fiber Blanket Mineral Fiber Blanket Mineral Fiber Blanket Mineral Fiber Blanket Expanded Perlite Expanded Perlite Expanded Perlite Expanded Perlite 17. Insulation Thickness: inches inches inches inches 18. Control On: Line Temperature Line Temperature Line Temperature Line Temperature Ambient Temperature Ambient Temperature Ambient Temperature Ambient Temperature 19. Controls Provide GFPD? Yes No Yes No Yes No Yes No 20. # of Tee Connections Required? 21. Notes: 22. Customer name: Company: Phone: Pipe Freeze Protection Project name: BUSINESS CARD

14 solutions to make a home winter safe SURFACE SNOW MELTING Raychem surface snow melting systems keep sidewalks, stairways and driveways free of snow and ice. Our product range allows you to choose the right solution for your application and budget from a self-regulating system for concrete surfaces and pavers that reduces heat output automatically as the pavement warms and is ideal for smaller areas; to an MI pre-terminated system for concrete, pavers, and asphalt which provides constant power output and is ideal for larger jobs. ELECTROMELT Cut-to-Length Heating Cable System Self-regulating heating cable for surface snow melting and anti-icing in concrete pavement. Voltage: 208 V; 240 V; 277 V; 347 V Control and sensor options: PD-Pro and GF-Pro, LCD-8 Snow Switch, SIT-6E Components: EMK heat shrinkable fittings MI Pre-terminated Heating Cable System HDPE jacketed copper sheathed heating cable for snow melting in concrete, mastic asphalt slab or road-grade asphalt slab. Voltage: 120 V to 600 V; Single or 3-Phase design; Control options: PD-Pro, GF-Pro, LCD-8, SIT-6E Components: n/a Surface Snow Melting Controller Selection Details GOOD BETTER BEST LCD-8 EC-TS PD-PRO & CIT-1 / SIT-6E Moisture and temperature sensing controller Aerial mounted sensor Up to 5-hour hold time (adjustable) Compatible with external contactors 16 A at 120 V Mechanical thermostat Ambient or line sensing Adjustable set point of 30 F to 110 F 25 thermistor sensor 30 A at V Temperature and moisture sensing controller Controller works w/ CIT-1 aerial and/or SIT-6E pavement mounted snow sensors Up to 8-hour hold time (adjustable) LED lights to indicate power and heat cycle Compatible with external contactors 30 A at V GF-PRO & CIT-1 / SIT-6E Temperature and moisture sensing controller Controller works w/ CIT-1 aerial and/or SIT-6E pavement mounted snow sensors Up to 8-hour hold time (adjustable) Built-in GFEP protection LED lights to indicate power and heat cycle 30 A at V 14 14THERMAL PENTAIR BUILDING SOLUTIONS For complete specifications and other design assistance, refer to the appropriate data sheets and application design guides available on our websites

15 SURFACE SNOW MELTING SYSTEM ESTIMATE FORM completed form to your Pentair Sales Rep for a complete Bill of Materials and quote! CHECK OUT SNOCALC, OUR ONLINE SURFACE SNOW MELTING DESIGN TOOL at by selecting the Commercial or Residential segment -> Resources and clicking on the SnoCalc design tool. Contractor: Tear here. Offer the left side to the homeowner / building owner. the worksheet to your Raychem Sales Rep to get a complete Bill of Materials and quote! 2016 Pentair. H /16 1. Building Type: House Small shop / strip mall High-rise residential /multi-use bldg. Commercial building 2. Project City, State: 3. Area Name: 4. Voltage: 120 V 208 V 240 V 277 V 120 V 208 V 240 V 277 V 120 V 208 V 240 V 277 V 120 V 208 V 240 V 277 V 347 V 480 V 600 V 347 V 480 V 600 V 347 V 480 V 600 V 347 V 480 V 600 V 5. Voltage Configuration: 1 Phase 3 Phase 1 Phase 3 Phase 1 Phase 3 Phase 1 Phase 3 Phase 6. Breaker Size: 20 A 30 A 40 A 50 A 20 A 30 A 40 A 50 A 20 A 30 A 40 A 50 A 20 A 30 A 40 A 50 A 60 A 80 A 100 A 60 A 80 A 100 A 60 A 80 A 100 A 60 A 80 A 100 A 7. Area Type: Concrete Concrete Concrete Concrete 8. Number of Steps: Asphalt Asphalt Asphalt Asphalt Pavers Pavers Pavers Pavers Stairs (on grade) Stairs (on grade) Stairs (on grade) Stairs (on grade) Stairs (elevated) Stairs (elevated) Stairs (elevated) Stairs (elevated) Wheel Tracks (concrete) Wheel Tracks (concrete) Wheel Tracks (concrete) Wheel Tracks (concrete) Wheel Tracks (asphalt) Wheel Tracks (asphalt) Wheel Tracks (asphalt) Wheel Tracks (asphalt) 9. Stair Width: feet feet feet feet 10. Stair Depth: inches inches inches inches 11. Riser Height: inches inches inches inches 12. Landing Area: sq. feet sq. feet sq. feet sq. feet 13. Total Area (not including landing): sq. feet sq. feet sq. feet sq. feet 14. Number of Expansion Joints: 15. Feet from Junction Box to Slab: feet feet feet feet 16. Junction Box Height Above Grade: feet feet feet feet 17. If Wheel Track Design, Length of Tracks: feet feet feet feet 18. Control: Control Only Control Only Control Only Control Only Control w/ Power Dist Control w/ Power Dist Control w/ Power Dist Control w/ Power Dist 19. Controls Provide GFPD? Yes No Yes No Yes No Yes No 20. Notes: 21. Customer name: Company: Phone: Surface Snow Melting Project name: BUSINESS CARD

16 solutions to make a home comfortable COMFORT FLOOR HEATING Nuheat electric floor heating systems are an ideal room-specific heat source option for both new construction or renovation projects. These easy-to-install systems may be installed under tile, stone, laminate/engineered wood floors. NUHEAT Mat System NUHEAT Cable System NUHEAT Mesh System Floor Heating Thermostats Pre-built like an electric blanket, Nuheat Mats are available in standard sizes or can be custom built to precisely fit any room with curves or angles. It is the easiest and quickest system to install. Voltage: 120 V or 240 V Available in over 70 standard off -the-shelf square and rectangular sizes Nuheat Custom Mats manufactured in only 3 days 12 watts/sq ft; 41 BTUs (15 watts/sq ft; 51 BTUs also available upon request) Nuheat Cable is perfect where on-site adjustments are required. The system includes newly designed cable guides and a low-profile cold lead. Voltage: 120 V or 240 V Over 30 kit sizes; largest 120V covers 120 sq ft and largest 240V covers 240 sq ft Mid-point marker on heating cable for easier planning May be installed at 12 watts/sq ft (41 BTUs), or 15 watts/sq ft (51 BTUs) The Nuheat mesh system is heating cable woven into an adhesive-backed red fiberglass mesh. The simple roll-out installation is customizable to any room shape. Voltage: 120 V, 208 V or 240 V Standard off-the-shelf mesh available in 14 sizes for 120 V, and 4 sizes for 240 V Features a low 3/16 in (3mm) profile 12 watts/sq ft The following thermostats are suitable for all floor heating systems and include built-in GFCI protection: Signature (WiFi-enabled programmable touchscreen) Home (programmable touchscreen) Harmony (programmable flush-mounted) Element (non-programmable) The following thermostat is suitable for the Nuheat mesh system and includes built-in GFCI protection: QuickStat-TC (programmable) 16 16THERMAL PENTAIR BUILDING SOLUTIONS For complete specifications and other design assistance, refer to the appropriate data sheets and application design guides available on our websites or

17 MEASURING Pick a corner of the room and use that as the starting point for your measurements. Remember that you must return to this starting point at the end of your measurements. An online measuring tutorial is available at Standard mat layout 1. Pick a corner of the room and use that as the starting point for your measurements. 2. Measure and draw the walls of the room on paper and record the measurements. 3. Measure and draw the location of cabinets and vanities, make sure to take the vanity measurement right up to the toe-kick. 4. Measure and draw the location of floor features such as vents and toilet drains (measure from the walls to the center of the toilet drain). 5. Indicate the thermostat location and voltage if known. Custom mat layout MAT 3-STEP EASY INSTALLATION 1. Trowel thinset 2. Roll mat onto thinset 3. Trowel thinset and install flooring WHERE TO PLACE THE ORDER Floor Heating Products Pentair Thermal Management Quote and order support: nuheatcustomercareteam@pentair.com Tel: Fax: HOW TO ORDER 1. Obtain an accurately measured floor plan including all perimeter dimensions and any vents or obstacles in the floor. Note the thermostat location. 2. Determine whether standard mats or custom mats are required. 3. If custom mats are required, the design, including all customer and job information to nuheatcustomercareteam@pentair.com. 4. Upon design confirmation, you will receive a quote for your project (quote turnaround is typically 24 hrs). 5. Submit a purchase order. Mats will arrive 67 business days from the time order is placed. Floor Heating FLOORHEATING 17 17

18 winter safety AREA SELECT ThE RIghT PROduCTS WINTERgARd Description Catalog # 100 TruckPak* 250 Reel Catalog # 50 Box 100 TruckPak* 250 Reel H H H WINTERgARd WET Description Catalog # Catalog # 50 Box 100 TruckPak* 250 Reel 500' Reel 1000' Reel H H H H H FROSTguARd PREASSEmBLEd Description Catalog # 6 Length 12 Length 18 Length 24' Length 36' Length 50' Length 75' Length 100' Length Catalog # 6 Length 12 Length 18 Length 24' Length FG2-6L FG2-12L FG2-18L FG2-24L ELECTROmELT See price list for the multitude of SKUs depending upon project needs PIPE ROOF Up to 2" diameter Up to 2 1/2" diameter Up to 6" diameter Up to 4" gutter with 1 run Up to 6" gutter with 2 runs SuRFACE SNOW melt 240 V; 6 40 F V V 120 V; 6 40 F 240 V; 6 40 F 120 V; 6 40 F 240 V; 6 40 F 120 V; 6 40 F See price list for the multitude of SKUs depending upon project needs mi PIPE FG1-6P FG1-12P FG1-18P FG1-24P FG1-36 FG1-50P FG1-75P FG1-100P Description PIPE H H H H H Description WET H H H Description 50 Box 100 TruckPak* 250 Reel 500' Reel 1000' Reel 120 V; 3 40 F H H WINTERgARd PLuS Description Catalog # 50 Box 100 TruckPak* 250 Reel dry APPLICATION *WinterGard TruckPaks contains 100 feet of heating cable, two H900 Hardwire Power Connection Kits, one H910 Splice or Tee Kit, and one H903 roll of Application Tape. **Although these can work with Roof & Gutter applications, they are ambient-sensing only. The PD-Pro & GF-Pro are more ideal because they work with snow and gutter sensors. Tel:

19 product chart CONTROLLERS ANd SENSORS PiPe** TC-3 Emk FITTINgS h915 - downspout hanger h914 - ROOF CLIPS (50) h913 - ROOF CLIPS (10) h912 - gel-filled ENd SEAL kit h910 - SPLICE & TEE h908 - PLug-IN CORd W/ gfi h903 - APPLICATION TAPE h900 - POWER CONNECTION kit ACCESSORIES PiPe** PiPe** AmC-F5 AmC-1A Ambient Ambient or sensing; line sensing Fixed 35 F Fixed set set point point 40 F 22 A at 125/ 15 Amp 250/480 V PiPe** EC-TS Ambient Ambient sensing sensing; Adjustable Adjustable set point 15 F set point 30 F to 140 F to 110 F 22 A at 125/ 30 A at /480 V 277 V PiPe** SST-2 r&g, SM r&g, SM r&g, SM r&g, SM LCd-8 Pd-PRO gf-pro CIT-1 r&g git-1 Ambient or Snow Switch; Snow and ice Snow and ice Snow aerial Gutter line sensing operates controller controller sensor sensor heaters at Fixed set Single circuit; Single circuit; temperatures point 40 F 120 V 30 ma GFEP below 38 F Works with up 30 A at 100 Works with up 277 V; to 2 sensors to 2 sensors 240 V 30 ma GFEP SM SIT-6E Pavement sensor w H900 w H900 w H900 w H900 w H900 w H900 w H900 w H900 w H900 w H900 w H900 w H900 w H900 w H900 w H900 w H900 w H900 w H900 w H900 w H900 w H900 w H900 w H900 w H900 w H900 w H900 Pipe - Pipe Freeze Protection; R&G = Roof & Gutter De-Icing; SM = Surface Snow Melting. All Pentair trademarks and logos are owned by Pentair or its global affiliates Pentair reserves the right to change specifications without prior notice Pentair. en-reswintersafetyproductchartuselect-sb-h /16

20 NORTH AMERICA Tel: Fax: Tel: Fax: All Pentair trademarks and logos are owned by Pentair. All other brand or product names are trademarks or registered marks of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice Pentair. THERMAL BUILDING SOLUTIONS EN-DistributorHandbook-SB-H /16

SAFETY & COMFORT FOR THE HOME RESIDENTIAL MARKET U.S. PLUMBING CANADA PLUMBING AND ELECTRICAL

SAFETY & COMFORT FOR THE HOME RESIDENTIAL MARKET U.S. PLUMBING CANADA PLUMBING AND ELECTRICAL SAFETY & COMFORT FOR THE HOME RESIDENTIAL MARKET U.S. PLUMBING CANADA PLUMBING AND ELECTRICAL THERMAL BUILDING SOLUTIONS WWW.PENTAIRTHERMAL.COM solutions to make a home winter safe PIPE FREEZE PROTECTION

More information

COMMERCIAL & RESIDENTIAL MARKETS U.S. ELECTRICAL

COMMERCIAL & RESIDENTIAL MARKETS U.S. ELECTRICAL COMMERCIAL & RESIDENTIAL MARKETS U.S. ELECTRICAL THERMAL BUILDING SOLUTIONS WWW.PENTAIRTHERMAL.COM Because winters can be harsh In winter, freezing temperatures can be a latent danger for buildings and

More information

COMMERCIAL & RESIDENTIAL SELF-REGULATING HEATING PRODUCTS APPLICATION AND DESIGN GUIDE EUROPE, MIDDLE EAST, AFRICA

COMMERCIAL & RESIDENTIAL SELF-REGULATING HEATING PRODUCTS APPLICATION AND DESIGN GUIDE   EUROPE, MIDDLE EAST, AFRICA WWW.PENTAIRTHERMAL.COM NORTH AMERICA Tel: +1.800.545.6258 Fax: +1.800.527.5703 Tel: +1.650.216.1526 Fax: +1.650.474.7711 thermal.info@pentair.com ASIA PACIFIC Tel: +86.21.2412.1688 Fax: +86.21.5426.2917

More information

Commercial and Residential Self-Regulating Heating Products

Commercial and Residential Self-Regulating Heating Products Commercial and Residential Self-Regulating Heating Products Application and Design Guide H53585 (800) 545-6258 www.tycothermal.com Table of Contents Introduction 1 Heating Cables Selection Guide 1 Product

More information

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System Pipe Freeze Protection and Flow Maintenance 1. Pipe Freeze Protection and Flow Maintenance Introduction XL-Trace System This step-by-step design guide provides the tools necessary to design a Raychem XL-Trace

More information

COMMERCIAL HEAT TRACING PRODUCTS AND SERVICES. thermal ManaGeMent.

COMMERCIAL HEAT TRACING PRODUCTS AND SERVICES. thermal ManaGeMent. COMMERCIAL HEAT TRACING PRODUCTS AND SERVICES thermal ManaGeMent www.pentairthermal.com thermal ManaGeMent We provide quality solutions for winter safety, comfort and performance to building and infrastructure

More information

ROOF AND GUTTER DE-ICING ICESTOP SYSTEM

ROOF AND GUTTER DE-ICING ICESTOP SYSTEM ROOF AND GUTTER DE-ICING ICESTOP SYSTEM This step-by-step design guide provides the tools necessary to design a Raychem IceStop roof and gutter de-icing system. For other applications or for design assistance,

More information

COMMERCIAL HEAT TRACING PRODUCTS AND SERVICES

COMMERCIAL HEAT TRACING PRODUCTS AND SERVICES COMMERCIAL HEAT TRACING PRODUCTS AND SERVICES THERMAL MANAGEMENT SOLUTIONS WWW.THERMAL.PENTAIR.COM BUILDING & INFRASTRUCTURE SOLUTIONS We provide quality solutions for winter safety, comfort and performance

More information

ROOF ICE MELT (RIM) SYSTEM

ROOF ICE MELT (RIM) SYSTEM Pipe Freeze Protection and Flow Maintenance ROOF ICE MELT (RIM) SYSTEM FOR CONCEALED ROOF & GUTTER DE-ICING Fire Sprinkler System Freeze Protection PRODUCT OVERVIEW The Raychem RIM System is our premier

More information

XL-Trace System Application and Design Guide

XL-Trace System Application and Design Guide R XL-Trace System Application and Design Guide Pipe Freeze Protection and Flow Maintenance for Commercial Construction Applications Pipe Freeze Protection and Flow Maintenance 1. Pipe Freeze Protection

More information

Roof and Gutter De-Icing

Roof and Gutter De-Icing Roof and Gutter 1. Pipe Freeze Protection and Flow Maintenance Introduction IceStop System This step-by-step design guide provides the tools necessary to design a Raychem IceStop roof and gutter de-icing

More information

COMMERCIAL HEAT TRACING. Products and Services

COMMERCIAL HEAT TRACING. Products and Services COMMERCIAL HEAT TRACING Products and Services NVENT We provide quality solutions for winter safety, comfort and performance to building and infrastructure design, construction, operation and maintenance

More information

ROOF ICE MELT (RIM2) SYSTEM

ROOF ICE MELT (RIM2) SYSTEM FOR CONCEALED ROOF & GUTTER DE-ICING PRODUCT OVERVIEW The Raychem RIM System is our premier engineered, aesthetically elegant, concealed roof & gutter de-icing solution to prevent ice dams, icicles, and

More information

Self-regulating Roof Heat and Gutter Trace Cable

Self-regulating Roof Heat and Gutter Trace Cable Self-regulating Roof Heat Gutter Trace Cable Most roof deicing applications are best served by using Warmzone s self-regulating heat cable. The heat cable can be installed in gutters downspouts to keep

More information

Self-regulating Roof Heat Cable

Self-regulating Roof Heat Cable Self-regulating Roof Heat Cable Most roof deicing applications are best served by using Warmzone s self-regulating heat cable. The heat cable can be installed in gutters downspouts to keep structures safe

More information

Toll Free:

Toll Free: Toll Free: 888.488.9276 www.warmzone.com sales@warmzone.com 19 Self-regulating Roof Heat Gutter Trace Cable Most roof deicing applications are best served by using Warmzone s self-regulating heat cable.

More information

Principle of Operation:

Principle of Operation: SELF-REGULATING HEATERS Standard Overjacket Standard Metal Braid Stranded Copper Conductors Self Regulating Conductive Core Thermoplastic Elastomer Jacket Description: Nelson Type CLT selfregulating heater

More information

Gardian W51. Approvals

Gardian W51. Approvals Gardian W51 120 V pre-assembled electric heating cables for pipe freeze protection and roof & gutter de-icing Installation Instructions Description Gardian W51 120 V pre-assembled self-regulating heating

More information

Freezer Frost Heave Prevention

Freezer Frost Heave Prevention Freezer Frost Heave Prevention 1. Pipe Freeze Protection and Flow Maintenance RaySol System Mineral Insulated Heating Cable System This step-by-step design guide provides the tools necessary to design

More information

IceStop System Installation and Operation Manual

IceStop System Installation and Operation Manual IceStop System Installation and Operation Manual For Roof and Gutter De-Icing WARNING: Fire and Shock Hazard. The IceStop roof and gutter de-icing system must be installed correctly to ensure proper operation

More information

Toll Free:

Toll Free: Toll Free: 888.488.9276 www.warmzone.com sales@warmzone.com 19 Self-regulating Pipe Trace Cable Pipe Trace Solutions Self-regulating Heat Trace Cable Warmzone s self-regulating pipe tracing cable is an

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 220533 - HEAT TRACING FOR PLUMBING PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes plumbing piping heat tracing for freeze prevention, domestic hot-water-temperature maintenance, and

More information

Toll Free:

Toll Free: 1 Pipe Trace Solutions Self-regulating Heat Trace Cable ProLine s self-regulating pipe tracing cable is an ideal solution for industrial, commercial residential pipe freeze protection as well as process

More information

IceStop System INSTALLATION AND OPERATION MANUAL FOR ROOF AND GUTTER DE-ICING SYSTEMS

IceStop System INSTALLATION AND OPERATION MANUAL FOR ROOF AND GUTTER DE-ICING SYSTEMS IceStop System INSTALLATION AND OPERATION MANUAL FOR ROOF AND GUTTER DE-ICING SYSTEMS THERMAL MANAGEMENT SOLUTIONS WWW.THERMAL.PENTAIR.COM Important Safeguards and Warnings WARNING: FIRE AND SHOCK HAZARD.

More information

FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM

FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM This step-by-step design guide provides the tools necessary to design a Raychem XL-Trace fire sprinkler freeze protection system. For other applications

More information

SMPG3 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL. For three-phase heating cables PRODUCT OVERVIEW

SMPG3 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL. For three-phase heating cables PRODUCT OVERVIEW SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL For three-phase heating cables Mounting brackets Nameplate HTC energized light Power on light Heater cycle timed control Heater (3R only)

More information

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines System for flow maintenance of above ground greasy waste disposal lines with line sensing control,

More information

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines System for flow maintenance of aboveground fuel oil lines with Proportional Ambient Sensing Control (PASC),

More information

HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM

HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM This step-by-step design guide provides the tools necessary to design a Raychem HWAT Hot Water Temperature Maintenance System. For additional information,

More information

PLSRR Heat Trace Cable Data Sheet

PLSRR Heat Trace Cable Data Sheet PLSRR Heat Trace Cable Data Sheet PLSRR is self-regulating heat cable that can be used for roof / gutter heating pipe tracing. The cable features a flexible, UV-stabilized thermoplastic elastomer overjacket

More information

protection Constant wattage heating cables Self-regulating heating cables Temperature controllers

protection Constant wattage heating cables Self-regulating heating cables Temperature controllers snow & ice protection Constant wattage heating cables Self-regulating heating cables Temperature controllers Protection of roofs, gutters and downpipes Snow and ice protection systems protect against:

More information

The IceFree Eave System

The IceFree Eave System Material Recycled Aluminum Alloy 6063 Temper - T5 Sizes. Sold in 5 panel extrusions. IceFree 8 Eave Panel (for eaves up to 12 deep) IceFree 12 Eave Panel (for eaves up to 18 deep) IceFree 18 Eave Panel

More information

QuickNet System Installation Manual Manuel d installation du système QuickNet Manual de instalación del sistema QuickNet

QuickNet System Installation Manual Manuel d installation du système QuickNet Manual de instalación del sistema QuickNet QuickNet System Manual Manuel d installation du système QuickNet Manual de instalación del sistema QuickNet Floor heating system Système de chauffage par le plancher Sistema de calefacción de pisos Table

More information

SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES PRODUCT OVERVIEW

SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES PRODUCT OVERVIEW SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES Mounting brackets Heater thermostat (3R only) Power on light HTC energized light Heater (3R only) Snow/Ice

More information

Technology for human beings that is, compatible with nature, creating permanent HEAT TRACING Dreams that can greatly improve the quality of life,

Technology for human beings that is, compatible with nature, creating permanent HEAT TRACING Dreams that can greatly improve the quality of life, Technology for human beings that is, compatible with nature, creating permanent HEAT TRACING Dreams that can greatly improve the quality of life, based on sophisticated technology. Quality Global Technology

More information

Design Guide Design Notes Design Examples Technical Data Sheets Expanded Capabilities Specifications Warranty

Design Guide Design Notes Design Examples Technical Data Sheets Expanded Capabilities Specifications Warranty Introduction HWAT Design Guide This step-by-step design guide provides the tools necessary to design a Raychem HWAT Hot Water Temperature Maintenance System. For additional information, contact your Pentair

More information

FTC-HST WARNING: CAUTION:

FTC-HST WARNING: CAUTION: FTC-HST XL-Trace, RaySol, and IceStop Splice/Tee Connection Kit Installation Instructions Description The Raychem FTC-HST is used with RaySol system heating cables to make splice connections (on slab bottoms

More information

H908 WinterGard Plug-in Power Connection Kit with End Seal

H908 WinterGard Plug-in Power Connection Kit with End Seal R R H908 WinterGard Plug-in Power Connection Kit with End Seal Installation Instructions Description The H908 is a plug-in, ground-fault-protected power connection kit for use with WinterGard H311, H611,

More information

Heating cable solutions for temperature-related problems

Heating cable solutions for temperature-related problems Heating cable solutions for temperature-related problems EasyHeat Residential and Commercial Solutions Depend on EasyHeat products for proper pipe temperatures, free-flowing roof gutters, safer walkways

More information

Toll Free:

Toll Free: 1 ProLine s electric radiant floor heating system is one of the most popular and durable floor heating solutions on the market. Available pre-spaced in mats with an adhesive backing or on the spool, the

More information

CSI Master Format 2012 Guide Specification for: Hot Water Temperature Maintenance (HWAT) Systems

CSI Master Format 2012 Guide Specification for: Hot Water Temperature Maintenance (HWAT) Systems CSI Master Format 2012 Guide Specification for: Hot Water Temperature Maintenance (HWAT) Systems System for temperature maintenance of domestic hot water supply systems with energy efficient time based

More information

XL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance

XL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance XL-Trace System Installation and Operation manual for pipe freeze protection and flow maintenance Thermal management WWW.PENTAIRTHERMAL.COM Important Safeguards and Warnings WARNING: FIRE AND SHOCK HAZARD.

More information

INDUSTRIAL HEAT TRACE

INDUSTRIAL HEAT TRACE INDUSTRIAL HEAT TRACE INDUSTRIAL HEAT TRACE www.valin.com CABLE SELECTION Selecting the right cable is as much art as it is science. The chart below can help guide you through the selection of products

More information

Design Guide and Installation Details for Self-Regulating Heating Cable

Design Guide and Installation Details for Self-Regulating Heating Cable Design Guide and Installation Details for Self-Regulating Self-Regulating s Design Guide and Installation The RSCC 2700 self- regulating heating cable is available with either a tinned copper or stainless

More information

CATALOG. Toll Free:

CATALOG. Toll Free: P R O D U C T CATALOG Toll Free: 888.488.9276 WWW.WARMZONE.COM sales@warmzone.com Warmzone Radiant Product Catalog Contents General Information - Warmzone Products and Services...3 Project Photos...4 Professional

More information

Heat Tracing Sales Mt. Airy, Maryland Heating Cable. Cut to Length in Field. Description

Heat Tracing Sales Mt. Airy, Maryland Heating Cable. Cut to Length in Field. Description Self-Regulating Protection D E C B A Self-Regulating, Energy Efficient Designed for Protection Max. Exposure Temp. 185 F (Power Off) Cost Effective for Commercial Construction Protection Applications Protection

More information

XL-Trace System Installation and Operation Manual

XL-Trace System Installation and Operation Manual XL-Trace System Installation and Operation Manual Pipe freeze protection and flow maintenance WARNING: Fire and shock hazard. This heat-tracing system must be installed correctly to ensure proper operation

More information

Warranty Info: ETI s warranty policy can be viewed at:

Warranty Info: ETI s warranty policy can be viewed at: Troubleshooting and testing procedures for the following controls and snow sensors: Controllers: APS-3B, APS-4, APS-3C, APS-4C, and EUR-5A Snow Sensors: CIT-1, GIT-1, and SIT-6E, these snow sensors work

More information

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated)

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated) CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated) Typical system for snow melting of pavers, concrete and asphalt surfaces with temperature and moisture sensing control,

More information

Longline Heating. Contents. Introduction

Longline Heating. Contents. Introduction Longline Heating This section provides an overview of the longline heat-tracing technologies available from Pentair Industrial Heat Tracing Solutions. For complete design assistance, contact your Pentair

More information

sulfur transport pipelines Safe, Reliable and Cost-Effective Heat Management System

sulfur transport pipelines Safe, Reliable and Cost-Effective Heat Management System sulfur transport pipelines Safe, Reliable and Cost-Effective Heat Management System INDUSTRIAL HEAT TRACING SOLUTIONS WWW.pentairthermal.com industrial solutions As the world s largest provider of complete

More information

Keep your home snow and ice free with. WARMUP Outdoor Heating Solutions. From the world s best-selling electric floor heating brand

Keep your home snow and ice free with. WARMUP Outdoor Heating Solutions. From the world s best-selling electric floor heating brand Keep your home snow and ice free with WARMUP Outdoor Heating Solutions From the world s best-selling electric floor heating brand Applications for stairs for walkways for driveways for roofs & gutters

More information

F1202 TRACE HEATING. Road & Ramp

F1202 TRACE HEATING. Road & Ramp Trace Heating Specialists Road & Ramp ROAD & RAMP HEATING ESH Trace Heating Ltd provide a comprehensive range of products to prevent the settlement of snow and formation of ice on roads, ramps and stairs.

More information

THERMAL MANAGEMENT SOLUTIONS

THERMAL MANAGEMENT SOLUTIONS Pipe Freeze Protection and Flow Maintenance ECW-GF, ECW-GF-DP Digital electronic controllers and remote display panel Fire Sprinkler System Freeze Protection ECW-GF with FTC-PSK pipe stand and power connection

More information

RayClic Connection System

RayClic Connection System RayClic Connection System RayClic-S Splice Kit RayClic-T Tee and End Seal Kit RayClic-X Cross and End Seal Kit Installation Instructions Description These kits are for use with Raychem IceStop, XL-Trace

More information

SPECIFICATION GUIDELINE FROST PROTECTION FOR PIPES. Tender Specification. Engineering Specification for Pipe Frost Protection. Contents.

SPECIFICATION GUIDELINE FROST PROTECTION FOR PIPES. Tender Specification. Engineering Specification for Pipe Frost Protection. Contents. Tender Specification Package #: Trace Heating Engineering Specification for Pipe Frost Protection Contents Y24 Trace heating 2 Appendix A Schematics & Drawings 8 Prepared by: Authorised by: Issued

More information

INSTALLATIONGUIDE. HotSeam TM Overview ICE ROOF

INSTALLATIONGUIDE. HotSeam TM Overview ICE ROOF INSTALLATION GUIDE forfor HotSeam HotSeam Overview Exposed heat cables with glued down retention clips on metal roofs have been the conventional way to drain ice dams for many years. HotEdge s patented

More information

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated) CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated) System for preventing frost heave in freezers, cold rooms and ice arenas with temperature control, monitoring,

More information

CATALOG. Toll Free:

CATALOG. Toll Free: P R O D U C T CATALOG Toll Free: 866.676.9276 WWW.PROLINERADIANT.COM sales@prolineradiant.com ProLine Radiant Product Catalog Contents General Information - ProLine Products and Services...3 Project Photos...4

More information

Anti frost. Snow Melting USA 2012 USA 2014

Anti frost. Snow Melting USA 2012 USA 2014 Anti frost USA 2014 USA 2012 1 Mat Resistance Wires Reinforced Braide PVC Jacketing Super strong aramid FEP Mat DomoTecK s Mat is the ideal heating element for outdoor de-icing. Our snow melting mat prevents

More information

Warm Feet For Uncoupling Membrane Pour membrane de désolidarisation. Installation Guide Floor Heating Cable

Warm Feet For Uncoupling Membrane Pour membrane de désolidarisation. Installation Guide Floor Heating Cable Warm Feet For Uncoupling Membrane Pour membrane de désolidarisation Installation Guide Floor Heating Cable 119A Sir Wilfrid Laurier Saint-Basile-le-Grand, (Québec), J3N 1M2 Tel: 1-450-482-1919 Toll Free:

More information

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10 MAKING MODERN LIVING POSSIBLE Installation Guide SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10 www.eh.danfoss.com Table of Contents 1 Introduction............................................. 3 1.1 Self-limiting

More information

Affiliations: Code Listings and Standards C O U N C I L

Affiliations: Code Listings and Standards C O U N C I L P r o d u c t C a t a l o g T a p e M a t W a r m W i r e U n d e r F l o o r S l a b H e a t C a b l e P r o M e l t M a t P r o M e l t C a b l e s u n t o u c h. c o m SunTouch: more SunTouch products

More information

SEASONAL MAINTENANCE SCHEDULE

SEASONAL MAINTENANCE SCHEDULE SEASONAL MAINTENANCE SCHEDULE Establishing and following a maintenance schedule is the best way to protect your investment, to ensure that by doing your maintenance you prevent the appearance of future

More information

Radiant Edge LT TM Ice Melt System Installation and Operation Guide Version 1.4

Radiant Edge LT TM Ice Melt System Installation and Operation Guide Version 1.4 Radiant Edge LT TM Ice Melt System Installation and Operation Guide Version 1.4 From This... To This... Thermodynamics analyzed. Applied. Summit Ice Melt Systems, Inc. 2911 Lake Forest Road PO Box 6928

More information

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS INDUSTRIAL AIR AND INFRARED RADIANT HEATERS Portable Unit Heaters Portable electric heaters are available in radiant-heat or fan-forcedair designs.

More information

JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS JB-RTD-STAND with Raychem heating cable DESCRIPTION The Raychem JB-RTD-STAND is a combination

More information

Polymer solutions Heating mat EM2-CM

Polymer solutions Heating mat EM2-CM 1.5 Polymer solutions 1. Application EM2-CM is a constant wattage heating mat for simple, fast, and effective ramp and accessway heating to prevent snow and ice formation. The EM2-CM mat is particularly

More information

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL ECW-GF with FTC-PSK pipe stand and power connection kit ECW-GF using RayClic power connection kit ECW-GF-DP remote display panel available only with

More information

TT3000 and TT5000 Series

TT3000 and TT5000 Series TT3000 and TT5000 Series Bulk Sensing Cable Installation Instructions General Notes Do s and Don ts General Information These instructions detail techniques used to install TT3000 or TT5000 bulk sensing

More information

Carbon Film Installation Instructions

Carbon Film Installation Instructions Contents Page 2 Page 3 Page 4 Page 5 Page 8 Product Overview Pre-Installation & Electrical Provision Depron Underlay Installation Carbon Film Installation - Under Wood/Laminate Flooring Notes & Trouble

More information

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS SECTION 238313- RADIANT-HEATING ELECTRIC CABLES / MATS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Electric radiant snow melting mats or cables embedded in concrete or asphalt slabs, or embedded under brick

More information

Drexan Energy Systems Inc.

Drexan Energy Systems Inc. Drexan Energy Systems Inc. SPECIFICATION Self-Regulating Heating Cable PipeGuard Warm Page 1 of 8 CONTENTS 1. SCOPE 2. PRODUCTS 3. TESTING 4. MARKINGS 5. PACKING 6. GENERAL 7. INSTALLATION AND COMMISSIONING

More information

HWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS

HWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS HWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS DESCRIPTION The Raychem HWT-P Power Connection and End Seal Kit is for use with HWAT heating cables. Materials for one power connection

More information

radiant floor heating Floor Heating Mats Floor Heating Cables Thermostats

radiant floor heating Floor Heating Mats Floor Heating Cables Thermostats radiant floor heating Floor Heating Mats Floor Heating Cables Thermostats Radiant floor heating: A modern comfort solution Floor heating s vertical temperature distribution is the closest form of heating

More information

Fire Sprinkler Freeze Protection Design / Install Guide

Fire Sprinkler Freeze Protection Design / Install Guide Fire Sprinkler Freeze Protection Design / Install Guide Page 1 of 23 Fire Sprinkler System Freeze Protection Design / Install Guide CONTENTS Introduction Page 3 System Overview Page 4 Fire Suppression

More information

Surface Snow Melting and. Icing ElectroMelt. Introduction. ElectroMelt Self-Regulating Heating Cable System

Surface Snow Melting and. Icing ElectroMelt. Introduction. ElectroMelt Self-Regulating Heating Cable System Surface Snow Melting and Anti-Icing ElectroMelt 1. Pipe Freeze Protection and Flow Maintenance Introduction ElectroMelt Self-Regulating Heating Cable System This step-by-step design guide provides the

More information

ELEKTRA RadiantFloor Heating

ELEKTRA RadiantFloor Heating www.elektra.eu ELEKTRA RadiantFloor Heating single-side powered MD Heating Mats Installation manual ELEKTRA Heating Mats For the proper installation and operation of the ELEKTRA radiant floor heating system,

More information

Thermal Devices, Inc. Mount Airy, Maryland USA Heating Cable. Cut to Length in Field

Thermal Devices, Inc. Mount Airy, Maryland USA   Heating Cable. Cut to Length in Field Thermal Devices, Inc. Mount Airy, Maryland UA www.thermaldevices.com RF elf-regulating Freeze Protection D E C B A Max. Exposure Temp. 185 F (Power Off) Cost Effective for Commercial Construction Freeze

More information

Electric Floor Heating & Snow Melting Solutions

Electric Floor Heating & Snow Melting Solutions SunTouch Product Catalog Electric Floor Heating & Snow Melting Solutions SunTouch.com Comfort, convenience & reliability SunTouch products are designed to add comfort, convenience and reliability to homes

More information

Hot Water Temperature Maintenance. HWAT System. Product Selection and Design Guide

Hot Water Temperature Maintenance. HWAT System. Product Selection and Design Guide Hot Water Temperature Maintenance HWAT System Product Selection and Design Guide A Solutions Company Tyco Thermal Controls provides complete heat tracing and specialty wiring solutions for the industrial,

More information

EN RaychemRIM2StandardInstallationManual IM H /16 1

EN RaychemRIM2StandardInstallationManual IM H /16 1 EN RaychemRIM2StandardInstallationManual IM H59375 01/16 1 EN RaychemRIM2StandardInstallationManual IM H59375 01/16 2 Bylin Engineered Systems 4800 Golden Foothills Parkway, El Dorado Hills, CA 95762 Phone:

More information

Underwood Heater Installation Manual

Underwood Heater Installation Manual Underwood Heater Installation Manual Contents Important Safeguards and Warnings... 3 1 General Information... 3 1.1 Use of the Manual... 3 1.2 Safety Guidelines... 3 1.3 Remember to measure resistance...

More information

AKOCABLE Heating Cable Solutions Electrical Tracing

AKOCABLE Heating Cable Solutions Electrical Tracing AKOCABLE Heating Cable Solutions Electrical Tracing www.ako.com AKOCABLE HEATING CABLE TECHNOLOGIES Mineral insulation Series type heating cable Used for high temperature maintenance and/or exposure Fluoropolymer

More information

SELF-REGULATING PIPE TRACING HEATER CABLE

SELF-REGULATING PIPE TRACING HEATER CABLE SELF-REGULATING PIPE TRACING HEATER CABLE Installation & Operation Manual TABLE OF CONTENTS GENERAL INFORMATION... 1 How Heating Systems Work...1 PRODUCT SELECTION... 1 RECEIPT & STORAGE... 1 Receipt...1

More information

Data Sheet. Self regulating heating tapes. RS stock numbers

Data Sheet. Self regulating heating tapes. RS stock numbers Data Pack K Issued September 2001 232-3125 Data Sheet Self regulating heating tapes RS stock numbers 379-312 The information contained within this sheet regarding applications and installation of RS WinterGard

More information

Classic Mats Installation Manual

Classic Mats Installation Manual Classic Mats Installation Manual 1 Classic Mats WarmTouch Classic Mats are the ideal Electric floor warming systems, designed by DomoTecK, for installation under tile, stone or marble. WarmTouch Classic

More information

Design Guide. The world s best-selling floor heating brand

Design Guide.  The world s best-selling floor heating brand Design Guide www.warmup.com The world s best-selling floor heating brand Design Guide The Design Guide is a selection of real layouts and projects with MSRP pricing and product information. Use it with

More information

First Trace Heating Product Details

First Trace Heating Product Details First Trace Heating Product Details and specifying guide Contents 2 4 6 9 9 10 Refrigeration Safe Trace Product Diagrams 11 Components www.first-traceheating.co.uk Introduction Specification Maximum Exposure

More information

Department of General Services Real Estate Services Division Professional Services Branch Additional Detailed Instructions (ADI)

Department of General Services Real Estate Services Division Professional Services Branch Additional Detailed Instructions (ADI) Department of General Services Real Estate Services Division Professional Services Branch Additional Detailed Instructions (ADI) PJECT: Altaville Fire Station WORK ORDER NO. 125047 Automotive Shop Replacement

More information

MODEL GF PRO AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

MODEL GF PRO AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL MODEL GF PRO AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL This manual refers to the Snow Switch Model GF Pro control panel manufactured since October 31, 2013, which uses a universal (100 277 VAC; 50/60

More information

JBS-100-EC Electronic controller replacement kit for JBS-100-ECP-A and JBS-100-ECW-A Installation Instructions

JBS-100-EC Electronic controller replacement kit for JBS-100-ECP-A and JBS-100-ECW-A Installation Instructions JBS-100-EC Electronic controller replacement kit for JBS-100-ECP-A and JBS-100-ECW-A Installation Instructions Description The Raychem JBS-100-EC is a replacement kit that can be used to replace the electronic

More information

FreezGard. Self-regulating crankcase heater. Product Overview

FreezGard. Self-regulating crankcase heater. Product Overview Self-regulating crankcase heater Product Overview When compressors operate in cold areas, refrigerant can migrate into the crankcase oil whenever the compressor is not running. On start-up, this can cause

More information

Tank Heating. Introduction. Self-Regulating Heating Cables

Tank Heating. Introduction. Self-Regulating Heating Cables Tank Heating This step-by-step design guide provides the tools necessary to design a tank heating system for temperature maintenance using electric heating cables or tank heating pads. For design assistance,

More information

amuheat Cable Mat floor heating systems Installation Manual CM02-12

amuheat Cable Mat floor heating systems Installation Manual CM02-12 amuheat floor heating systems Cable Mat Installation Manual CM02-12 Table of Contents Introduction 1 2 Cable Mat Important Installation Guidelines Tools & Materials Needed for Installation Kit Contents

More information

Pressure Washers (courtesy of Mi-T-M Corp.)

Pressure Washers (courtesy of Mi-T-M Corp.) Pressure Washers (courtesy of Mi-T-M Corp.) What is pressure washing? Pressure washing or power washing is the growing practice of cleaning using high pressure water spraying. The high pressure water spraying

More information

AKOCable Heating Cable Solutions Electrical Tracing

AKOCable Heating Cable Solutions Electrical Tracing Heating Cable Solutions Electrical Tracing HEATING CABLE TECHNOLOGIES Mineral insulation Series type heating cable Used for high temperature maintenance and/or exposure Fluoropolymer cover Used in long

More information

ComfortTile Floor Heating Systems

ComfortTile Floor Heating Systems ComfortTile Floor Heating Systems Luxurious Warmth for Your Floors The systems are easily installed under all types of floor surfaces to provide comfortable, even floor heat. ComfortTile radiant floor

More information

SAFETY INFORMATION AND WARNINGS

SAFETY INFORMATION AND WARNINGS SAFETY INFORMATION AND WARNINGS Pilot Duty The GF Pro snow and ice control cannot be used for Pilot Duty applications. Resistive Load Usage Only This product is not for use with Inductive loads. Inductive

More information

DESIGN GUIDELINES. THERMAL building SOLUTIONS

DESIGN GUIDELINES. THERMAL building SOLUTIONS DESIGN GUIDELINES XL-Trace LSZH Self-Regulating Heating Cables for Pipe Freeze Protection Systems THERMAL building SOLUTIONS WWW.PENTAIRTHERMAL.COM Pipe Freeze protection system overview SBS Control Panel

More information