FM Approvals & Water Mist Systems. Paul Bardsley Engineer, FM Approvals

Size: px
Start display at page:

Download "FM Approvals & Water Mist Systems. Paul Bardsley Engineer, FM Approvals"

Transcription

1 FM Approvals & Water Mist Systems Paul Bardsley Engineer, FM Approvals

2 Presentation Outline Introduction to FM Global Introduction to FM Approvals FM Water Mist Systems

3 Who are FM Global? The largest industrial and commercial insurance company in the world. $5+ billion in annual premiums $6+ billion in reserves No outstanding debt

4 FM Global An Overview Mutual ownership company Financially very strong (top 500 of Fortune 1000) Possess significant underwriting expertise Integrate engineering & insurance underwriting A genuine belief that all loss is preventable Possess an extensive global client base Global bet on FM Approvals engineering

5 FM Global Clients

6 FM Global Clients

7 FM Global Network Over 110 Countries Represented Over 133,000 insured locations 1871 Engineers 60,000 Annual Visits

8 Presentation Outline Introduction to FM Global Introduction to FM Approvals FM Water Mist Systems

9 Introduction to FM Approvals Member of the FM Global Group Research Engineering

10 Mission Statement FM Approvals approves and certifies products and services with unique focus on: Objectively testing property loss prevention products and services and certifying those that meet rigorous loss prevention standards; Encouraging the development and use of Approved products and services that improve and advance property loss prevention practices.

11 FM Approvals and Risk Put another way FM Approvals conducts tests on property loss prevention products and services, the requirements that are applied are described in rigorous loss prevention standards which have been written by FM Approvals, the requirements in the standards are established from data and evidence collected through the research activities of FM Global.

12 FM Approvals and Risk An FM Approved product has achieved certain minimum levels of performance against a defined series of requirements. FM Approved products are the building blocks that can be used by FM Global and others to ensure loss prevention. Once the risk has been identified and fully understood, FM Approved products can be used, together with the appropriate installation standards to protect property.

13 The importance of research? What you are about to see is a FM Global research project looking at how much water is needed to control and extinguish a fire in a rack storage system of cardboard boxes containing expanded plastic food trays. You will see a fire introduced in the middle of the boxes and once the temperature at the ceiling level has achieved the required trigger temperature, water heads will be released at a known delivery rate.

14 Test Arrangement Watch the colour of the smoke drawn into the 20 Mega Watt Calorimeter. The fire will trigger the ceiling mounted extinguishing system which will deliver a constant 20 litres per minute per square metre. There are 24 x1m 3 boxes, arranged in the racking in two rows.

15

16 The water that was delivered was not enough to control or extinguish the fire. With this arrangement, there is a very high probability that the building and contents would have been destroyed. Can FM Approvals certify anything? No!

17 What can Approvals do? After hundreds of these tests, run with different configurations and arrangements, the research tests will have established how much water is required to control and to extinguish the fire. When used with the correct installation standards, the combined effect of the FM Approved product and FM Global s research knowledge, the property & commodity is protected.

18 FM Approvals History In June 1897, the Inspection Department of the Associated Factory Mutual Fire Insurance Companies Approved its first Electrical Fittings.

19 FM Approvals in Europe Notified Body under Construction Products Directive EOTA member for innovative CPD products. Notified Body under the ATEX Directive IECEx Certification Body UKAS Accredited Certification Body Member of Standards Committees & Industry Groups Undertaking FM Approval projects for US, Canadian, European & International Markets

20 FM Approvals Laboratory A look at the history of FM Approvals Test Laboratory.

21 Everett Testing Facility 1932

22 Norwood Test Facility 1947

23 W. Glocester Test Center 1967 Hydraulics 1992 Test Center 1967

24 New Research Campus 2003 Nat Haz Labs Large Fire Lab Hydraulics Labs Electrical Labs Research Labs Approvals Labs Offices

25 Hydraulics Laboratory

26 Hydraulics Laboratory

27 Hydraulics Laboratory

28 Water Mist Test

29 Sprinkler Flow Test

30 2004 FM Approvals Offices Norwood, MA W. Glocester, RI

31 FM Approvals International Windsor (2006) Beijing (2005) Shanghai (2007) Hong Kong (2007) Singapore (2006)

32 FM Approvals Hydraulics Products Fire pumps, Fire pump controllers, Diesel engine fire pump drivers, Sprinkler system components & extinguishing systems, Water mist systems.

33 FM Approvals Offering in Europe FM APPROVED 1725

34 Our Approval is different. We have a common interest in the performance of the Water Mist System This is what makes our Approval unique in the marketplace.

35 Presentation Outline Introduction to FM Global Introduction to FM Approvals FM Water Mist Systems

36 FM Standard 5560: Water Mist Systems Defines the criteria for water mist system performance and test requirements for the FM Approval of land based systems. When installed in accordance with the recommendations described in FM Global Data Sheets will provide a Highly Protected Risk. Will be a truly living document which will be refined and expanded as needed for new applications of occupancy protection and for new water mist technology.

37 FM Standard 5560: Water Mist Systems FM Global Property Loss Prevention Data Sheet 4-2 provides evaluation and installation criteria for FM Approved Water Mist Systems.

38 FM Standard 5560: Water Mist Systems FM Approval requires successful compliance of the overall system operation and reliability against the requirements of FM Standard 5560 including General Requirements, Performance Requirements and Operational Requirements.

39 FM Standard 5560: Water Mist Systems FM Standard 5560 includes specific requirements for the components that make up the Water Mist System including Nozzles; Valves; Gas storage Cylinders; Detection Devices; Fittings & Piping; Hoses; Pneumatic Components; Switches; Tanks and Pumps.

40 FM Standard 5560: Water Mist Systems FM Standard 5560 also examines the performance of the system with respect to Verification of Hydraulic Calculations; Design, Installation, Operation and Maintenance Manuals; System Acceptance and Commissioning Documents and Fire Test Performance.

41 FM Standard 5560: Water Mist Systems Occupancy Protection Applications 1. Machinery Spaces & Special Hazard Machinery Spaces 2. Protection of Combustion Turbines 3. Light Hazard Occupancies 4. Protection of Wet Benches and Other Similar Processing Equipment 5. Local Application 6. Industrial Oil Cookers 7. Protection of Computer Room Sub Floors

42 FM Standard 5560: Water Mist Systems 1. Machinery & Special Hazard Machinery Spaces Machinery Spaces: Rooms with machinery using fuel or lubrication fluids with volatiles less than or equal to light diesel Special Hazard Machinery Spaces: Rooms with machinery using fuel or lubrication fluids with volatiles less than or equal to Heptane & Storage of less than 110 gallons of flammable liquids

43 FM Standard 5560: Water Mist Systems 1. Machinery & Special Hazard Machinery Spaces Fire Test Protocol Test protocol is dependent upon the volume of the enclosure; Combination of shielded and unshielded spray and pool fires up to 6MW in size; Conducted with machinery mockup in place and Spay cooling (no fire) test to assess for casing warp

44 FM Standard 5560: Water Mist Systems 2. Protection of Combustion Turbines Total Flooding Application Prevent and limit damage from fires internal and external to the turbine

45 FM Standard 5560: Water Mist Systems 2. Protection of Combustion Turbines Fire Test Protocol Test protocol is dependent upon the volume of the enclosure; Combination of shielded and unshielded spray and pool fires; Conducted with combustion turbine mockup in place and Spay cooling (no fire) test to assess for casing warp

46 FM Standard 5560: Water Mist Systems 3. Light Hazard Occupancies Non-storage and nonmanufacturing areas: Inappropriate for ordinary hazard occupancies Limited Ceiling heights, Water supply conditions & room size.

47 FM Standard 5560: Water Mist Systems 3. Light Hazard Occupancies Fire Test Protocol Restricted & Unrestricted Ceiling Height Approval FM Approved quick response nozzles must be used. Nozzles are set at manufacture's maximum spacing All fire tests conducted for 10 minutes after the activation of the first nozzle and any remaining fire shall be extinguished manually

48 Thermal images of Light Hazard Small Compartment fire (first) & Large Compartment fire (second).

49 FM Standard 5560: Water Mist Systems 4. Wet Benches & Other Similar Equipment Equipment which consist of ventilated and unventilated compartments, spin rinse dryers, alcohol vapor dryers, chemical and mechanical polishing tools, and step and repeat exposure systems

50 FM Standard 5560: Water Mist Systems 4. Wet Benches & Other Similar Equipment Fire Test Protocol Specific FM Approvals simulated clean room and wet bench mockup Water mist system installed as specified by manufacturer Air flow of the open face wet bench shall be the maximum specified by the manufacturer Subsurface and working surface polypropylene and flammable liquid pool fires

51 FM Standard 5560: Water Mist Systems 5. Local Application Protection of Special Hazards and Equipment: Paper machines and pulp dryers, Dip tanks & coaters, Belt Conveyers, Waste solvent recovery, Mechanical refrigeration.

52 FM Standard 5560: Water Mist Systems 5. Local Application Fire Test Protocol Seven test fire scenarios: Square diesel pool; channel diesel pool; heptane spray; diesel spray and pool; obstructed pool; offset pool & diesel spray with external ignition source Suitable automatic interlocks are required as part of overall system FM Approval, i.e., electrical system shutdown, fuel supply shutoff and ventilation shutdown.

53 FM Standard 5560: Water Mist Systems 6. Industrial Oil Cookers Non-Insulated conveyor fryers & batch kettles where the main hazard is overheating of oil to Actual Ignition Temperature (AIT)

54 FM Standard 5560: Water Mist Systems 6. Industrial Oil Cookers Fire Test Protocol Mock-up size determined from manufacturers specifications Open flames extinguished within one minute from start of discharge Water mist cannot cause thermal damage to cooker

55 FM Standard 5560: Water Mist Systems 7. Computer Room Sub Floors Protection of mainframe electronic computer systems and major equipment or process control computer systems located in the sub-floor

56 FM Standard 5560: Water Mist Systems 7. Computer Room Sub Floors Fire Test Protocol Three type of Fire Test Conducted at maximum nozzle spacing Water shall be supplied for at least 10 minutes

57 FM Standard 5560: Water Mist Systems General Examination & Performance Tests Seat Leakage Hydrostatic Strength Operating Pressure Durability Cycling Extreme Temperatures Operation Salt Spray Corrosion (Residue Build-Up) Vibration Resistance Valve Locking/Supervision Ability Friction Loss Determination Seals and Gaskets

58 FM Standard 5560: Water Mist Systems Water Mist Nozzle Tests Assembly Load/Frame Strength Strength of Heat Responsive Element Leakage Hydrostatic Strength 30-Day Leakage Water Hammer Operating Temperature (Liquid Bath) Air Bath Hang-Up of Operating Parts Strength of Deflector (Flow Endurance) Vacuum High Ambient Temperature Exposure (90 Day Test) Thermal Shock (Glass Bulb Nozzles Only) Discharge Coefficient, K-Factor Moist Air Corrosion - Salt Spray Corrosion - Stress Cracking Corrosion - Carbon Dioxide-Sulfur Dioxide Corrosion - Hydrogen Sulfide Vibration Rough Use and Abuse High Temperature Exposure Freezing Minimum Operating Pressure Process Residue Conductivity (C-Factor) Sensitivity - Response Time Index (RTI) Sensitivity (Recessed, Flush, and Concealed Types) Sensitivity (Air Oven) Water Mist Discharge Characteristics Impingement Protective Caps

59 FM Standard 5560: Water Mist Systems Other Performance Requirements and Examinations Complete System Documentation Review Hydraulic Calculations Method Installation, Operation and Maintenance Manual Manufacturing and Production Tests Demonstrated Quality Control Program Facilities and Procedures Audit (Quality Assurance) System Acceptance and Commissioning Installation Inspections by FM Global Field Engineers with feedback for continuous improvements

60 For more information contact. FM Approvals at: 1 Windsor Dials, Windsor, Berkshire, UK, SL4 1RS. Tel: +44 (0) Fax: +44 (0) cpd@fmapprovals.com Website:

61 FM Approvals Ltd Thank You Believing that all losses are preventable

UL Listings & FM Approvals Their Impact on Fire Sprinkler System Performance/Design

UL Listings & FM Approvals Their Impact on Fire Sprinkler System Performance/Design UL Listings & FM Approvals Their Impact on Fire Sprinkler System Performance/Design Presented by Center for Life Safety Education July 18, 2006 Featuring Speakers Kerry M. Bell, P.E. - Underwriters Laboratories

More information

Application of BS 8489 to the Protection of Generator Enclosures. IWMA, BRE 22 nd March 2017 Dr Tim Nichols CPhys FIFireE

Application of BS 8489 to the Protection of Generator Enclosures. IWMA, BRE 22 nd March 2017 Dr Tim Nichols CPhys FIFireE Application of BS 8489 to the Protection of Generator Enclosures IWMA, BRE 22 nd March 2017 Dr Tim Nichols CPhys FIFireE Agenda Generator Enclosure Characteristics Generator Fire Characteristics Machinery

More information

Water Mist Fire Protection Systems for the Protection of Industrial Oil Cookers. 8th March 2016 Dr Tim Nichols CPhys MIFireE

Water Mist Fire Protection Systems for the Protection of Industrial Oil Cookers. 8th March 2016 Dr Tim Nichols CPhys MIFireE Water Mist Fire Protection Systems for the Protection of Industrial Oil Cookers 8th March 2016 Dr Tim Nichols CPhys MIFireE Industrial Oil Cookers 2 What are Industrial Oil Cookers Large cooker of food

More information

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE The Protection of Machinery Spaces by means of the Local Application of Water Mist Dr. Tim R. Nichols CPhys FIFireE 2017 Johnson Controls. All rights reserved. Tyco Fire Products LP is a subsidiary of

More information

The Worldwide Use of Fire Sprinklers

The Worldwide Use of Fire Sprinklers The Worldwide Use of Fire Sprinklers Russell P. Fleming, P.E. President, National Fire Sprinkler Association (USA) Managing Director, International Fire Sprinkler Association United States Fire Sprinkler

More information

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust Safer.Smarter.Tyco. Watermist fire protection Technology you can trust / 2 / / 3 / Trust in Tyco Tyco s AquaMist Systems Tyco Fire Protection Products helps to keep people, property and the environment

More information

Making sense of risk Risk engineering. Metalworking operations

Making sense of risk Risk engineering. Metalworking operations Making sense of risk Risk engineering Metalworking operations Metalworking operations Metalworking operations involve the fabrication of ferrous or nonferrous metal products, structural metal products,

More information

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS 12 December 1996 Ref. T4/4.01 GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS 1 The Maritime Safety

More information

FM Approval Standard For Cavity Walls And Rainscreens

FM Approval Standard For Cavity Walls And Rainscreens FM4411 - Approval Standard For Cavity Walls And Rainscreens Mark D. Tyrol, P.E. FM Approvals Air Barrier Association of America (ABAA) is a Registered Provider with The American Institute of Architects

More information

Legislation, Standards and Technology. Figure 1: 1897 Approved Electrical Fittings

Legislation, Standards and Technology. Figure 1: 1897 Approved Electrical Fittings Legislation, Standards and Technology FM Approvals Roots in the industrial revolution 1835 and the development to present by John Rennie and Bill Lawrence Figure 1: 1897 Approved Electrical Fittings In

More information

The FM Global Research Campus

The FM Global Research Campus The FM Global Research Campus 1 2 > > Delivering Superior Loss Prevention Through Research and Testing FM Global s 1,600 acre (648 ha) Research Campus is the premier center for property loss prevention

More information

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

I wish I could protect my business with the most suitable Water Mist solution to fit my needs. I wish I could protect my business with the most suitable Water Mist solution to fit my needs. Wish granted! Tyco AquaMist systems are a versatile and highly efficient fire-fighting resource, featuring

More information

WATER MIST SYSTEMS. Table of Contents

WATER MIST SYSTEMS. Table of Contents FM Global Property Loss Prevention Data Sheets 4-2 January 2013 Page 1 of 16 WATER MIST SYSTEMS Table of Contents Page 1.0 SCOPE... 2 1.1 Changes... 2 2.0 LOSS PREVENTION RECOMMENDATIONS... 2 2.1 Equipment

More information

The requirements of BS Watermist Fire System standard and how to demonstrate compliance

The requirements of BS Watermist Fire System standard and how to demonstrate compliance The requirements of BS8489-1 Watermist Fire System standard and how to demonstrate compliance Bob Whiteley C. Eng.; F.I.Mech.E.; M.I.Fire E.; B.Tech(Hons) Chair: BSI Watermist Working Group Overview What

More information

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS Jukka Vaari 1, Amit Lior 2 1 2 VTT Technical Research Centre of Finland, Espoo, Finland Marioff Corporation Oy, Vantaa,

More information

The Science Behind Water Mist Protection of Typical Building Hazards

The Science Behind Water Mist Protection of Typical Building Hazards The Science Behind Water Mist Protection of Typical Building Hazards SUPDET 2014 Zachary Magnone, P.E. Zachary.Magnone@tycofp.com Presentation Goals What is water mist? How does it work? How is it tested

More information

Performance Based Fire Protection With Water Mist

Performance Based Fire Protection With Water Mist Performance Based Fire Protection With Water Mist the applications to industrial hazards, high rise buildings and other areas of interest PART 1 PART 2 PART 3 PART 4 PART 5 Marioff Corporation Why use

More information

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA Page 1 of 6 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Pendent Sprinkler VK500 is a fast response fusible element type sprinkler designed for early fire suppression. With a 14.0 (202

More information

INDUCED DRAFT HIGHBOY AND COUNTERFLOW/HORIZONTAL GAS FURNACE

INDUCED DRAFT HIGHBOY AND COUNTERFLOW/HORIZONTAL GAS FURNACE INDUCED DRAFT HIGHBOY AND COUNTERFLOW/HORIZONTAL GAS FURNACE USERS INFORMATION MANUAL MODELS FOR USE WITH NATURAL GAS MHA-50N, MHA-75N, MHA-100N, MHA-125N, MDA-50N, MDA-75N, MDA-100N, MDA-125N FOR USE

More information

Fire Protection for Printing Machines with High Pressure Water Mist

Fire Protection for Printing Machines with High Pressure Water Mist Fire Protection for Printing Machines with High Pressure Water Mist Dipl.-Ing. Rüdiger Kopp FOGTEC Fire Protection ruediger.kopp@fogtec.com 1 Case Study PRINOVIS Printing Company - PRINOVIS is Europe s

More information

Watermist Fire Protection of Plant Rooms

Watermist Fire Protection of Plant Rooms Guidance Note Watermist Fire Protection of Plant Rooms SCOPE This document sets out the requirements for protection of plant rooms with watermist systems and should be read in conjunction with BS8489-1.

More information

esfr pendent sprinkler vk510 (k25.2)

esfr pendent sprinkler vk510 (k25.2) Page 1 of 7 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Pendent Sprinkler VK510 incorporates the capability to suppress specific high-challenge fires. The addition of a larger K-Factor

More information

Proven Fire Fighting Efficiency for Large Transformers with High Pressure Water Mist

Proven Fire Fighting Efficiency for Large Transformers with High Pressure Water Mist Proven Fire Fighting Efficiency for Large Transformers with High Pressure Water Mist Dipl.-Ing. Rüdiger Kopp FOGTEC Fire Protection ruediger.kopp@fogtec.com 1 Water Mist for Transformer Fire Protection

More information

Setting the Standard in Third-party Certification

Setting the Standard in Third-party Certification Setting the Standard in Third-party Certification 1 Benefits enjoyed by FM Approvals customers FM Approvals can help you: Meet client demands Fulfill jurisdictional requirements Differentiate your product

More information

4 June This circular supersedes MSC/Circ.914. *** I:\CIRC\MSC\01\1272.doc

4 June This circular supersedes MSC/Circ.914. *** I:\CIRC\MSC\01\1272.doc INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: 020 7735 7611 Fax: 020 7587 3210 IMO E Ref.: T4/4.01 MSC.1/Circ.1272 4 June 2008 GUIDELINES FOR THE APPROVAL OF FIXED WATER-BASED

More information

File Ex643 Project 03NK31930 Project 04NK24425 Project 05NK25712 Project 06NK15719 Project 06NK06003 Project 06NK24531

File Ex643 Project 03NK31930 Project 04NK24425 Project 05NK25712 Project 06NK15719 Project 06NK06003 Project 06NK24531 WWW.UL.COM 1.877.ULHELPS / (1.877.854.3577) File Ex643 Project 03NK31930 Project 04NK24425 Project 05NK25712 Project 06NK15719 Project 06NK06003 Project 06NK24531 Issued: August 4, 2004 Revised: April

More information

Safer. Smarter. Tyco. I wish I had a flexible FM Approved Water Mist Solution to fit any industrial oil cooker.

Safer. Smarter. Tyco. I wish I had a flexible FM Approved Water Mist Solution to fit any industrial oil cooker. I wish I had a flexible FM Approved Water Mist Solution to fit any industrial oil cooker. I wish I could protect my industrial fryer installation with a fire protection solution that helps minimize collateral

More information

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Plan Review

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Plan Review MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Plan Review Minooka Fire Protection District Maintaining Your Fire Safety Systems Fire continues to be a major threat

More information

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications White Paper The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications Matthew Puzio, Senior Project Engineer, Fluid Control Technology, Victaulic updated

More information

An Overview of Extinguishing Systems for Computer Equipment

An Overview of Extinguishing Systems for Computer Equipment Risk Solutions An Overview of Extinguishing Systems for Computer Equipment Various types of automatic suppression systems are available for protecting computer equipment. This report discusses the uses

More information

Hot Work Permit. Can this job be avoided? Is there a safer alternative? Permit No.:

Hot Work Permit. Can this job be avoided? Is there a safer alternative? Permit No.: Hot Work Permit Can this job be avoided? Is there a safer alternative? Permit No.: A Hot Work Permit is required for any non-production or maintenance operation involving cutting, welding, grinding, open

More information

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA Page 1 of 7 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Pendent Sprinkler VK510 incorporates the capability to suppress specific high-challenge fires. The addition of a larger K-Factor

More information

VELMIST. System Mgły Wodnej Niskociśnieniowej

VELMIST. System Mgły Wodnej Niskociśnieniowej VELMIST System Mgły Wodnej Niskociśnieniowej VID Fire-Kill Innovative Solutions FM Approved Low Pressure Watermist nozzles for commercial and industrial applications. Complete range of Low Pressure Watermist

More information

TECHNICAL DATA NOTICE

TECHNICAL DATA NOTICE Page 1 of 5 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Upright Sprinkler VK520 is a fast response fusible element type sprinkler designed for early fire suppression. With a 14.0 (202

More information

FIREDETEC PRODUCT TECHNOLOGY: DIRECT & INDIRECT

FIREDETEC PRODUCT TECHNOLOGY: DIRECT & INDIRECT FIREDETEC TECHNOLOGY: DIRECT & INDIRECT PROPERTIES DIRECT SYSTEM (< 1m 3 ) DETECTION TUBE : FIRE DETECTION & EXTINGUISHING AGENT DISCHARGE IDEAL APPLICATION: Small and hard to reach enclosures (< 1m 3

More information

INSTALLATION & SERVICE MANUAL

INSTALLATION & SERVICE MANUAL INSTALLATION & SERVICE MANUAL ELECTRIC WATER HEATER THE WARRANTY ON THIS WATER HEATER IS IN EFFECT ONLY WHEN THE WATER HEATER IS INSTALLED AND OPERATED IN ACCORDANCE WITH LOCAL CODES AND THESE INSTRUCTIONS.

More information

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL SECTION 21 13 16 DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

Chapter 10: Laboratory Equipment

Chapter 10: Laboratory Equipment Chapter 10: Laboratory Equipment Guides to Standard Laboratory Equipment Equipment Approval Prior to purchasing or installing the following equipment, acquire the PI and CHO approval and consult with EHSO:

More information

RESEARCH TECHNICAL REPORT. SMART Sprinkler Protection for Highly Challenging Fires - Phase 2: Full-Scale Fire Tests in Rack Storage

RESEARCH TECHNICAL REPORT. SMART Sprinkler Protection for Highly Challenging Fires - Phase 2: Full-Scale Fire Tests in Rack Storage RESEARCH TECHNICAL REPORT SMART Sprinkler Protection for Highly Challenging Fires - Phase 2: Full-Scale Fire Tests in Rack Storage SMART Sprinkler Protection for Highly Challenging Fires - Phase 2: Full-Scale

More information

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems Products Solutions Services CT287 Hazardous Area Classifications and Protection Systems Slide 1 Topics covered Types of Hazardous Area classifications with focus on North America Types of hazardous protection

More information

REVISED GUIDELINES FOR THE DESIGN AND APPROVAL OF FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR RO-RO SPACES AND SPECIAL CATEGORY SPACES

REVISED GUIDELINES FOR THE DESIGN AND APPROVAL OF FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR RO-RO SPACES AND SPECIAL CATEGORY SPACES E 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: +44 (0)20 7735 7611 Fax: +44 (0)20 7587 3210 7 December 2018 REVISED GUIDELINES FOR THE DESIGN AND APPROVAL OF FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE November 2, 2007 Sprinkler 113a 1. DESCRIPTION The Viking Standard Response High Challenge Upright Large-Drop Sprinkler VK540 is a thermosensitive, glass-bulb sprinkler intended for use in protecting high

More information

CO 2 EXTINGUISHING SYSTEMS

CO 2 EXTINGUISHING SYSTEMS CO 2 EXTINGUISHING SYSTEMS CO 2 THE FIRE EXTINGUISHING CLASSIC: CLEAN, FAST AND RELIABLE TOTAL WALTHER, the acknowledged specialist in fire protection systems, has been manufacturing CO 2 extinguishing

More information

CO2 COCO GAS FLOODING SYSTEM

CO2 COCO GAS FLOODING SYSTEM PRE INTRODUCTION: CO2 COCO GAS FLOODING SYSTEM The importance of erection, testing and commissioning are overlooked, in many projects while installing fixed Co2 extinguishing system. It is very common

More information

Non-Storage / Special Protection / Storage Sprinklers

Non-Storage / Special Protection / Storage Sprinklers Non-Storage / Special Protection / Storage Sprinklers General Information Automatic sprinkler protection is recommended for industrial and other buildings having combustible construction or combustible

More information

FIRE SUPPRESSION SYSTEM

FIRE SUPPRESSION SYSTEM FIRE SUPPRESSION SYSTEM An effective fire suppression systems work fundamentally in three ways; The corner stone has to be an efficient means of early warning/detection. Followed by either an Oxygen reduction

More information

Water Mist Fire Suppression

Water Mist Fire Suppression Water Mist Fire Suppression How less water has a big impact. HELPING PROTECT YOUR BUSINESS AND VALUED ASSETS WITH WATER MIST FIRE PROTECTION SYSTEM INTRODUCTION Many buildings have specific areas that

More information

MORE THAN JUST FIRE PROTECTION

MORE THAN JUST FIRE PROTECTION MORE THAN JUST FIRE PROTECTION VID Fire-Kill is a world leading innovative developer and manufac turer of water based firefighting products, specializing in fixed water based systems utilizing environmental

More information

TECHNICAL NOTES. Literature Review on Hybrid Fire Suppression Systems. Peter Raia Michael J. Gollner University of Maryland

TECHNICAL NOTES. Literature Review on Hybrid Fire Suppression Systems. Peter Raia Michael J. Gollner University of Maryland TECHNICAL NOTES Literature Review on Hybrid Fire Suppression Systems Peter Raia Michael J. Gollner University of Maryland Fire Protection Research Foundation May 2014 The Fire Protection Research Foundation

More information

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions: SECTION 21 13 13 WET-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

(h) Pesticide Application.

(h) Pesticide Application. Fire Code Cannabis Amendment Section 13.20.066 is added to the Marysville Municipal Code to read in its entirety as follows: 13.20.066 Cannabis Growing, Processing, or Extraction Facilities (a) Application.

More information

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview Overview Modern combustion (or gas) turbine packages typically include an axial compressor, a combustion section and a turbine. Both compressor and turbine sections consist of one or more sets of fixed

More information

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM 1. GENERAL SPECIFICATION 1.1 An Engineered Carbon Dioxide Fire Suppression System shall be installed to meet a minimum design concentration of %, by volume in all designated spaces/areas to be protected.

More information

A sprinkler operates automatically when the heat-actuated element is heated to, or above, its thermal rating.

A sprinkler operates automatically when the heat-actuated element is heated to, or above, its thermal rating. Control / Residential / Suppression Mode Sprinklers Automatic sprinkler protection is recommended for industrial and other buildings having combustible construction or combustible occupancies. There are

More information

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids. SECTION 211300 FIRE SUPPRESSION SYSTEMS 1.0 All new and renovated buildings shall be provided with automatic sprinklers throughout and fire standpipe systems. The design and installation of these systems

More information

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University. 15500 - FIRE PROTECTION PART I DESIGN GUIDELINES A. General 1. Vertical fire pumps shall not be used at the University. 2. coupling piping shall be permitted for sprinkler and standpipe systems only. B.

More information

26 June 2001 *** I:\CIRC\MSC\1007.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

26 June 2001 *** I:\CIRC\MSC\1007.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: 020 7735 7611 Fax: 020 7587 3210 Telex: 23588 IMOLDN G IMO E Ref. T4/4.01 MSC/Circ.1007 26 June 2001 GUIDELINES FOR THE

More information

ISO INTERNATIONAL STANDARD. Fire protection Automatic sprinkler system Part 9: Requirements and test methods for water mist nozzles

ISO INTERNATIONAL STANDARD. Fire protection Automatic sprinkler system Part 9: Requirements and test methods for water mist nozzles INTERNATIONAL STANDARD ISO 6182-9 First edition 2005-11-01 Fire protection Automatic sprinkler system Part 9: Requirements and test methods for water mist nozzles Protection contre l'incendie Systèmes

More information

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design) Page:1 of 5 Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design) General Description The Model HF-RES Residential Flush Horizontal Side-Wall

More information

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE SECTION 21 1316 DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE PART 1 GENERAL 1.01 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department

More information

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE SECTION 21 1316 DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE PART 1 GENERAL 1.01 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department

More information

MORE THAN JUST FIRE PROTECTION

MORE THAN JUST FIRE PROTECTION MORE THAN JUST VID Fire-Kill is a world leading innovative developer and manufac turer of waterbased firefighting products, specializing in fixed water-based systems utilizing environmental friendly firefighting

More information

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco. TN-25 Tunnel Fire Protection System Safer. Smarter. Tyco. Expert Fire Protection for Tunnels Tyco provides a complete fire protection solution to protect the infrastructure of tunnels. Whether it is rail,

More information

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE SECTION 21 1313 WET-PIPE SPRINKLER SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Wet-pipe sprinkler system. B. System design, installation, and certification. C. Fire department connections. 1.02 RELATED

More information

GASEOUS HYDROGEN SYSTEMS

GASEOUS HYDROGEN SYSTEMS CHAPTER 7 GASEOUS HYDROGEN SYSTEMS SECTION 701 GENERAL 701.1 Scope. The installation of gaseous hydrogen systems shall comply with this chapter and Chapters 30 and 35 of the Fire Compressed gases shall

More information

Watermist nozzle issues and test methods

Watermist nozzle issues and test methods Watermist nozzle issues and test methods Louise Jackman Fire Protection Systems: Fit for purpose and reliable in service? BRE Global and the National Fire Chiefs Council (NFCC) seminar 24 April 2018 Part

More information

IMO. 4 June 1999 GUIDELINES FOR THE APPROVAL OF ALTERNATIVE FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR SPECIAL CATEGORY SPACES

IMO. 4 June 1999 GUIDELINES FOR THE APPROVAL OF ALTERNATIVE FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR SPECIAL CATEGORY SPACES INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: 0171-735 7611 Fax: 0171-587 3210 Telex: 23588 IMOLDN G Ref. T4/4.01 IMO E MSC/Circ.914 4 June 1999 GUIDELINES FOR THE APPROVAL

More information

Fixed fire protection solutions

Fixed fire protection solutions Risk Engineering Fixed fire protection solutions At a glance Fixed fire protection can reduce the severity of fire events and positively impact Risk Engineering Assessments. To provide an effective solution

More information

Managing Fire Protection System Impairment

Managing Fire Protection System Impairment Managing Fire Protection System Impairment Can your company afford to lose US$3.2 million in assets? Forgetting to restore an impaired sprinkler or other fire protection system at your facility could cost

More information

Fire Safety Compliance

Fire Safety Compliance Fire Safety Compliance Why Are My CO2 Systems Not S2 Compliant? For 2010 SESHA Hill Country By Matt Wyman, Managing Director KFPI Inc. September 28, 2010 Overview 1. SEMI S2 2. Fire Safety Requirements

More information

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971 INDEPENDENT FIRE EXTINGUISHER SALES & Your First Line of Defense Since 97 Suppression Sales i Installation i Service ABOUT IFESSAR In business since 97 Serve over 4000 customers Service Arkansas and Mississippi

More information

READY FOR CHANGE. A Guide for Meeting the NFPA Compliance Standard for Portable Fire Extinguishers

READY FOR CHANGE. A Guide for Meeting the NFPA Compliance Standard for Portable Fire Extinguishers READY FOR CHANGE A Guide for Meeting the NFPA 10-2010 Compliance Standard for Portable Fire Extinguishers THE CHALLENGES A QUICK REVIEW The NFPA 10 Standard contains many guidelines that may impact you

More information

Page 1 of 19 Committee Input No. 14-NFPA 33-2013 [ Global Input ] Type your content here... Supplemental Information File Name IndoorDraftforCI.docx Description This committee input would be added to new

More information

High Ceiling Protection

High Ceiling Protection High Ceiling Protection High Ceiling Protection An Investigation of Automatic Sprinkler Protection of Buildings with Non-Storage Occupancies and High Clearances Company Confidential 2 Background New architectural

More information

ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL THE MANUFACTURER OF THIS HEATER WILL NOT BE LIABLE FOR ANY DAMAGE RESULTING FROM FAILURE TO COMPLY WITH THESE INSTRUCTIONS. READ THESE

More information

Section 5.0: HAZARDOUS MATEIRAL STORAGE TABLE OF CONTENTS. A. Regulations, Standards and References 2. B. Scope 3. C. Approvals and Listings 3

Section 5.0: HAZARDOUS MATEIRAL STORAGE TABLE OF CONTENTS. A. Regulations, Standards and References 2. B. Scope 3. C. Approvals and Listings 3 Section 5.0: HAZARDOUS MATEIRAL STORAGE TABLE OF CONTENTS A. Regulations, Standards and References 2 B. Scope 3 C. Approvals and Listings 3 D. Design 4 E. Venting Cabinets 4 Page F. General Installation

More information

Explosion Protection Engineering Principles

Explosion Protection Engineering Principles Handbook of Fire and Explosion Protection Engineering Principles for Oil, Gas, Chemical and Related Facilities Second edition Dennis P. Nolan ELSEVIER AMSTERDAM BOSTON HEIDELBERG LONDON NEW YORK OXFORD

More information

DETECT-A-FIRE Heat Detectors

DETECT-A-FIRE Heat Detectors DETECT-A-FIRE Heat Detectors DETECT-A-FIRE thermal detectors are detection and release devices used for fire detection systems to activate alarms and actuate extinguishing systems. This rate compensated

More information

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler Bulletin 018 Rev. H Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler Bulletin 018 Rev. H Product Description The Reliable Model JL-14 Early Suppression Fast Response

More information

HI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen

HI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen HI-FOG for buildings Technical introduction Jussi Tiainen Protecting people, property and business continuity Contents Introduction to HI-FOG...3 How HI-FOG fights fire...4 Principles of HI-FOG system

More information

Model 3300 Technical Support and Installation Manual

Model 3300 Technical Support and Installation Manual Model 3300 Technical Support and Installation Manual Manual # T15011 Document Revision: A1 1. OVERVIEW 1 2. BASIC OPERATION 1 2.1 General 1 2.2 Field-of-View 2 2.3 Range 2 2.4 Environment 2 2.5 Configuration

More information

American Society of Safety Engineers Professional Development Conference June 9-12, Fire Protection. Stephen J.

American Society of Safety Engineers Professional Development Conference June 9-12, Fire Protection. Stephen J. American Society of Safety Engineers Professional Development Conference June 9-12, 2008 Session No. 101F Fire Protection Stephen J. Musur CSP, CFPS Chubb Group of Insurance Companies June 12, 2008 1 Fundamentals

More information

Vaults 5/03/2015. Introduction. Vault Types. Stand alone building Free standing structure VAULTS

Vaults 5/03/2015. Introduction. Vault Types. Stand alone building Free standing structure VAULTS Protect your Media Vault Protect your Assets Fire Protection Services Vaults Presented by Peter Glodic Introduction Vault Types VAULTS Vault Types Vault Construction Media Types Fire Types Extinguishing

More information

SUPPRESSION SALES I INSTALLATION I SERVICE

SUPPRESSION SALES I INSTALLATION I SERVICE SUPPRESSION SALES I INSTALLATION I SERVICE ABOUT FESSAR In business since 1973 Serve over 4000 customers Service Arkansas and Mississippi Trained and certified suppression technicians Technicians are Arkansas

More information

Method for testing the suppression performance of fire suppression systems installed in engine compartments of buses and coaches

Method for testing the suppression performance of fire suppression systems installed in engine compartments of buses and coaches 2014-09-19 SP Method 4912 Method for testing the suppression performance of fire suppression systems installed in engine compartments of buses and coaches 2014-09-19 page 2 (17) Copyright This test method

More information

Building Services Brochure

Building Services Brochure Building Services Brochure A Midland Brand A Midland Brand Redefining Flow Control Contents Section Page Introduction to Building Services 3 Wet & Dry RIser Equipment 4 Gas Detection & Pressure Proving

More information

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400 Page 1 of 6 1. DESCRIPTION The Viking Micromatic Standard Response Upright VK200 Sprinkler is a small, thermosensitive, glass-bulb spray sprinkler available in several different finishes, temperature ratings,

More information

micromatic standard response stainless steel sprinklers

micromatic standard response stainless steel sprinklers January 27, 2012 Sprinkler 15a 1. DESCRIPTION Viking Micromatic Standard Response Stainless Steel Sprinklers are small, corrosion-resistant, thermosensitive, glass-bulb spray sprinklers. The design consists

More information

Above Ground Fuel Tank Requirements

Above Ground Fuel Tank Requirements FIRE DEPARTMENT in cooperation with Above Ground Fuel Tank Requirements The purpose of this document is to provide information about general Fire Code requirements for above ground storage within the unincorporated

More information

Universal Fire Tube Boiler Wall Mount Models

Universal Fire Tube Boiler Wall Mount Models Universal Fire Tube Boiler Wall Mount Models USER S INFORMATION MANUAL Models WBRU**80W / 100W / 120W / 140W / 175W / 199W **NG denotes Natural Gas Model, LP Denotes Propane Model Heat Exchanger Bears

More information

Safety Practices Fire Protection Equipment Cold Weather

Safety Practices Fire Protection Equipment Cold Weather Page 1 of 14 Safety Practices Fire Protection Equipment Cold Weather Cold weather freeze-ups can damage or place vital fire protection systems out of service. Past losses include a single freezing-wind

More information

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed. Page of 5. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Pendent Sprinkler VK506 incorporates the capability to suppress specific high-challenge fires. The addition of a larger K-Factor allows

More information

OPERATION & MAINTENANCE MANUAL RHS680

OPERATION & MAINTENANCE MANUAL RHS680 OPERATION & MAINTENANCE MANUAL RHS680 Refrigerant Handling System 4075 East Market Street York, PA 17402 800-468-2321 tech@rtitech.com Manual P/N 035-80740-00 (Rev 1- May 22, 2001) TABLE OF CONTENTS Startup

More information

TRAINING BULLETIN TOOLS 1 May 27, 2011 PRESSURIZED WATER EXTINGUISHER

TRAINING BULLETIN TOOLS 1 May 27, 2011 PRESSURIZED WATER EXTINGUISHER TRAINING BULLETIN TOOLS 1 May 27, 2011 1. DESCRIPTION Weight is approximately 30 lbs. Water 2½ gallons. Operating Pressure: 100 psi @ 70 degrees F. Note: Water expelled in 55 seconds. Stainless Steel Cylinder

More information

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description Worldwide Contacts www.tyco-fire.com Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K and Pendent Extended Coverage Light and Ordinary Hazard General Description TYCO Series EC-11 and EC-14 Extended

More information

Factors Affecting Efficiency of Water Mist Suppression of Solid Combustible Fires in Open Environment

Factors Affecting Efficiency of Water Mist Suppression of Solid Combustible Fires in Open Environment Factors Affecting Efficiency of Water Mist Suppression of Solid Combustible Fires in Open Environment Hong-Zeng (Bert) Yu FM Global 16 th International Water Mist Conference September 21-22, 2016 Vienna,

More information

FEMA RECOMMENDATIONS FOR PROTECTION OF CURTAINED LIMITED FINISHING WORKSTATIONS USING UL 1254 LISTED PRE-ENGINEERED DRY CHEMICAL SYSTEMS

FEMA RECOMMENDATIONS FOR PROTECTION OF CURTAINED LIMITED FINISHING WORKSTATIONS USING UL 1254 LISTED PRE-ENGINEERED DRY CHEMICAL SYSTEMS FEMA RECOMMENDATIONS FOR PROTECTION OF CURTAINED LIMITED FINISHING WORKSTATIONS USING UL 1254 LISTED PRE-ENGINEERED DRY CHEMICAL SYSTEMS FEMA RECOMMENDATIONS ARE BASED UPON LIVE FIRE TESTING OF PREP STATIONS

More information

CertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML

CertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML CertifiedSafetyPassion SAFETY HI - TECH. Founded in 1990, Safety Hi-Tech is a customer-focused provider of innovative fire suppression solutions, focusing on Clean Agent Extinguishing Systems. Safety Hi-Tech

More information

Portable Fire Extinguishers

Portable Fire Extinguishers Portable Fire Extinguishers Workbook Activities The following activities have been designed to help you. Your instructor may require you to complete some or all of these activities as a regular part of

More information

FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures

FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures Building Name: Building Address: Plan Prepared By (please print): Date: Revision Date Comments Approval FIRE SAFETY MAINTENANCE

More information