Changes for EN50131 BS8243 PD6662

Size: px
Start display at page:

Download "Changes for EN50131 BS8243 PD6662"

Transcription

1 Changes for EN50131 BS8243 PD6662

2 STANDARDS CHANGE PRIOR TO 1 ST JUNE 2012 To view a list of Castle and Pyronix products which are compliant and download certificates visit: WHAT IS PD6662:2010? PD6662:2010 is a revision of the PD6662:2004 document, to which British alarm installers have been working. There has been a dual running of the two standards since 31 st May 2010, and from 1 st June 2012 only PD6662:2010 can be used. The documents which are incorporated into the British PD6662:2010 scheme are: EN :2006+A1:2009 (General Requirements) EN :2009 (Control and Indicating Equipment) EN :2008 (Power Supplies) DD CLC/TS :2008 (Installation Guidelines) EN :2009 (Fog device systems) BS8243:2010 (Configuration for Confirmed Alarms) DD263:2010 (Maintenance and Remote Support) PD6662:2010 will be required for new installations that need a URN for police response or for existing installations where a new URN is needed. Pyronix and Castle have been actively involved with the bodies writing the new standards and have been working to make sure that all products will meet the requirements and will be ready for installation prior to the changeover. In this document we will cover the changes relating to installations in the UK. WHAT S NEW? The biggest part of the change from the installer s point of view is DD243. It has been replaced with BS8243 and includes changes that will be of benefit to installers and their clients. BS8243 is just one part of the overall change and we cannot pick and choose which part of the standards we can use. It is all or nothing, and we have a deadline of 1 st June 2012 at which point the old PD6662:2004 will no longer be available to us so we will have made the switch by then. All Grade 3 devices must have an off-the-wall tamper switch. 1

3 Plugs may be used for mains connection, providing removal protection is fitted, at grade 2. All devices must be labelled with the applicable version of the standard. In particular Castle products will all be raised to v9 software to easily identify panels suitable for use from June 2012 onwards. All Castle and Pyronix products will be clearly marked on the cartons and on the product itself with a label that informs you of the standard, security grade and environmental class that the product is suitable for. Example: Much of the work is with the manufacturers to make changes to the alarm equipment, hardware and software so that you, our customers, the installers, can make your changes as easily and simply as possible. CHANGES TO ARC SIGNALS BS8243 INTRUDER AND HOLD UP ALARM SYSTEMS DESIGNED TO GENERATE CONFIRMED ALARM CONDITIONS It is required that a separate channel is used to communicate Tamper to the ARC when using pin alarms from the ATE loom or Fast Format from the digi. The control panel will now no longer send an Unconfirmed message if a tamper event occurs. It will instead send the Tamper signal. The ARC should be instructed to action a Tamper alarm as they would an unconfirmed intruder alarm. 2

4 The ARC will need to understand how to deal with messages from these new alarm systems. Now the ARC may receive a Tamper signal followed by a Confirmed signal, this will indicate either that a tamper has been followed by an intrusion or that two tampers have occurred so that the event is now Confirmed and appropriate action should be taken. If the ARC receives an Unconfirmed signal followed by a Confirmed signal, this indicates two intruder type detectors have activated and the event is now Confirmed and appropriate action should be taken. Also if the ARC receives a HU signal followed by Confirmed they will need to action this as a Confirmed HU event. See more information on this subject later in this document in the section Hold Up Device Confirmation. INTRUDER CONFIRMATION DETECTORS When using a confirmation detector such as the Pyronix TMD15, the BS8243 clause states that it should be declared at installation. This would typically be with the URN application. DURESS The use of a duress code is now permissible again at Grades 3 and 4. It should be noted however that this is only with the agreement of the local police authority, which will need to be obtained separately for each site. ENTRY DOOR CONTACT Using a PIR as the trigger for entry route is now allowed, although this does require the use of a digital key. Digital key is the new term for Portable Ancillary Control Equipment (PACE), e.g. a tag/fob. 3

5 The wording for this clause is important. The standard says that the contact may be omitted ONLY if it is NOT PRACTICABLE to fit the contact. This is not a licence to never fit a door contact again but an exception, accepting that in some circumstances it is not possible to do so. It is important to note that this does not change the rest of the rules. This is altering the entry route requirements only, not the exit requirements. The alarm must still be set by a deliberately operated device and not a timed exit. This means a Push-to-Set (PTS) button must still be used if a door contact is not used. CONFIRMATION DURING ENTRY Confirmation during entry is a major step in the direction of security. The number of detectors off of the entry route required to trigger, after entry and pre-alarm timers have expired, has now been reduced from two to one. Detectors that are not a part of the entry route which are triggered during entry time (stray) can also now be counted at the end of entry time following a 30 second delay from their being activated. Also note that the 30 second delay can now start during the entry time, so that a confirmed signal can be generated sooner after an intrusion via the entry route. SETTING SETTING AND UNSETTING As before, there are a number of methods available for setting and unsetting the intruder alarm system. Let s look at the subtle changes to this most basic of functions for the intruder alarms system. The setting procedure is now split into two distinct stages. The first starts the setting routine from within the building and the second ends it from outside (see BS paragraph 2). First the system must be commanded to set either with the keypad, the proximity reader or a radio fob. 4

6 Second the exit procedure must be terminated. This is typically achieved by the closing of the final exit door or pressing a Push-To- Set button. UNSETTING Typically unsetting is achieved using clause using a tag. The tag is now called a digital key instead of a PACE but the function is the same. When in this mode the panel must be programmed to restrict PIN use. This forces the user to use the tag and will not allow the use of a PIN code to unset the system, until after an entry timeout alarm has been generated. Other methods of unsetting require the use of a lock on the final door that would be connected to the control panel, which will prevent the door being opened unless the alarm has been switched off or confirmation has been disabled (there is a site option to disable confirm on entry if required). These are excellent ways of protecting the premises as the door being attacked will generate an instant alarm and will doubtlessly be followed by the activation of a PIR, which will confirm the activation and thus the police can be called much faster. However this is much more expensive and consideration should be given to how practical this is and how much extra security is actually gained. This, as always, comes down to your risk assessment during the design of the alarm system. HOLD UP DEVICE CONFIRMATION Confirmation for intruder signals, which has been talked about for many years, has had a significant impact on reducing false alarms. When the subject turns to Hold Up (HU) or Panic Alarms, there is a different view and it has been the source of much debate. Confirmation is not required for a new installation or on any existing system but is preferred. In the ACPO Policy (Police Response to Security Systems Policy 2011), it is referred to as Intervention. Intervention is only required to regain police response of a system that has lost response to the HU Unique Reference Number (URN). With this change, we can still use the same HU devices we currently do and we only need to deal with confirmation on a system that has 5

7 lost the HU URN. To apply for a replacement URN, the system will need to have a method of confirmed HU installed. Hold-Up Alarm System (HAS) confirmation can be one or a combination of these four methods: Audio confirmation Visual confirmation Sequential confirmation Telephone confirmation COMBINED CONFIRMATION HU DEVICES The idea is that a single device contains more than one means of generating an alarm, which are transferred to the control panel separately. A typical example, if pressed once, will call the ARC (alarm receiving centre) with the un-confirmed message, and if then subsequently pressed and held for a period of time, the device will call the ARC with the confirmed message. This would complement a call back system (telephone confirmation) and would override the 90 second delay that the ARC must wait before actioning the call. CONVENTIONAL HU DEVICES Alternatively the HU buttons would have to be positioned in such a way that two can be pressed if circumstances require them. So perhaps one near the entrance of the house or the counter of the shop, and then another further into the premises that can be pressed as the user would retreat into the building when in danger, or by another person aware of the danger. The HU alarm will now have its own confirmation timer, which must be set between 8 and 20 hours. This will be defaulted at 8 hours. Designers will need to consider effective confirmation facilities and minimising false alarms when installing new HU devices. 6

8 Castle panels use the same confirmation channel of the communicator to signal to the ARC so extra channels are not required for this purpose. So sending HU + Confirmed will be received as a Confirmed HU signal or Unconfirmed intruder + Confirmed will be received as a confirmed intruder alarm signal. EN :2006+A1:2009 BACK TAMPER AT GRADE 3: CLAUSE The Euro panel Large enclosure has been updated with a back tamper. We have also created a shroud that allows the back tamper to work when the panel is fitted with the extended stand-off feet. EN :2008 POWER SUPPLY UPDATE The Euro panels have had a physical modification to handle the new standard, improving the power supply unit (PSU) protection. If the power lines are shorted an over-current regulator will activate and protect the PSU. When the short is removed the PSU can return to normal and is unharmed. EN :2009 WARNING DEVICE FAULT RECOGNITION: CLAUSE The Pyronix Deltabell has been updated with a new version for Grade 3 installations. The current Deltabell E, Deltabell Plus and Deltabell X will confirm to Grade 2. The new Grade 3 Deltabells will be called Deltabell E G3, Deltabell Plus G3 and Deltabell X G3. All versions of the Deltabell also have an improved battery to support 30 minutes of ring time from its own battery. The G3 versions have been updated with battery monitoring and a fault relay so, when used in a Grade 3 system, the relay can be connected to a fault input on the control equipment. Also the Deltabell will monitor the integrity of the siren trigger wire. This will be achieved with a pull down resistor and, if enabled, will cause the bell to ring should the trigger wire be cut. 7

9 The Euro panels have been modified to support the use of the fault output. The tamper return will now be connected via the relay with a 6k8 ohm resistor bridge that will allow the tamper return to report Healthy, Fault and Tamper conditions separately. The output is separate so the Deltabell can be connected to any control panel and match the required connection method. EN :2009 ACCESS LEVELS CLAUSE There is now an alternative to the EN requirement for level 2 (user) authorisation for level 3 (engineer) access. The Engineer may now access the Intruder Alarm System at Grades 2 and 3 without level 2 authorisation (either by code or in writing), provided that a warning device is triggered and it is notified to the ARC. The Intruder alarm will make an audible warning during the process of entering the engineer menu. A suitable output type (59 Engineer Access ) is available to provide the signal to the ARC - which will remain active until exiting from the menu. This will, of course, require an additional communicator channel if fast format is in use. The original level 2 authorisation functionality remains in the Manager menu, so can still be used as previously e.g. if insufficient communicator channels are available. DD263 COMMISSIONING, MAINTENANCE AND REMOTE SUPPORT This document dictates how up and downloading software should be used. This adds a few refinements to the InSite and ARM services but these are sensible and formalise the idea of remote access by giving reasonable guidance. The installer must use passwords for each of the operators that use the software and they MUST log out when they are not using the software. This is a sensible requirement, we already have a password system within InSite and therefore the other requirements are part of the installer s procedure. At Grade 3, DD263:2010 clause 4.2c prevents the use of the autoanswer mode as implemented in InSite. Either the Panel dials or 8

10 dial-back options (permitted by 4.2 (a) and (d)) should be selected instead. Panel dials will allow the user (or an engineer at site) to initiate the remote session or dial-back will identify an incoming call and then call the remote PC back on the pre-determined number to confirm the panel is talking to the correct computer. DD263 also includes requirements for commissioning and preventative maintenance that can be simplified by using the functionality of InSite especially ARM. M:\Word Documents\Engineer_Manuals\PD6662\Standards change prior to 1st June 2012_no-flag-RMKT docx 9 RMKT March 2012

11 CONTACTS Guy Dodd UK Sales Director Bryan Evans Gary Rogers Jim Lovett Mark Blackledge Account Manager: Account Manager: Account Manager: Account Manager: North East, Scotland and Northern Ireland Midlands and Wales Southern England Northern England

12 KEEP CALM AND CARRY ON Secure House, Braithwell Way, Hellaby, Rotherham South Yorkshire, S66 8QY Telephone: Fax: v3.0b Pyronix Ltd, 2012 RMKT090296

ALL YOU NEED TO KNOW ABOUT THE NEW STANDARDS IN ONE HANDY POCKET GUIDE. Updated for 2016 to include IA1501. Brought to you by: In association with:

ALL YOU NEED TO KNOW ABOUT THE NEW STANDARDS IN ONE HANDY POCKET GUIDE. Updated for 2016 to include IA1501. Brought to you by: In association with: ALL YOU NEED TO KNOW ABOUT THE NEW STANDARDS IN ONE HANDY POCKET GUIDE Updated for 2016 to include IA1501 Brought to you by: In association with: This Pocket Guide has been designed as a quick reference

More information

Changes to UK alarm standards. PD6662:2010 April Honeywell Security

Changes to UK alarm standards. PD6662:2010 April Honeywell Security Changes to UK alarm standards PD6662:2010 April 2012 Honeywell Security Update of PD6662:2004 What is PD6662:2010? Calls up the latest versions of the EN5013x series standards Key changes include: EN50131-1:2006

More information

PD6662:2010. A guide from Honeywell Security Group

PD6662:2010. A guide from Honeywell Security Group PD6662:2010 A guide from Honeywell Security Group Contents 1. Introduction 2. What is PD6662:2010? 3. When do the changes apply? 4. Key changes 4.1 - EN50131-x 4.2 - PD6662:2010 4.3 - BS8243 5. Honeywell

More information

HARDWIRED CONTROL PANELS

HARDWIRED CONTROL PANELS USER'S GUIDE HARDWIRED CONTROL PANELS Cooper Security Limited 2007 Every effort has been made to ensure that the contents of this book are correct. However, neither the authors nor Cooper Security Limited

More information

2200 and 2200L ALARM CONTROL SYSTEMS

2200 and 2200L ALARM CONTROL SYSTEMS 2200 and 2200L ALARM CONTROL SYSTEMS OPERATING INSTRUCTIONS MODELS: 2200 (fitted software 3.4 or later) 2200L (fitted software 3.9L or later) Castle Care-Tech Ltd. 2200/2200L Alarm System Operating Manual

More information

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM 2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM OPERATING INSTRUCTIONS MODELS: 2300 2500 2700 This information is relevant to systems fitted with Issue 4.1 (or later) Master Keypad Software, also to Networked

More information

EURO User Manual. For use with EURO 76, MSX 162, MSX 280 software: Version 9.1 or above RINS1527-2

EURO User Manual. For use with EURO 76, MSX 162, MSX 280 software: Version 9.1 or above RINS1527-2 EURO User Manual For use with EURO 76, MSX 162, MSX 280 software: Version 9.1 or above RINS1527-2 You ve Made the Right Choice Contents Introduction 1-6 Using EURO Panel with Code or Tag 7-8 Intelligent

More information

Euro ONE. RENDER ALARMS Your security, above all else. User Manual. t: f:

Euro ONE. RENDER ALARMS Your security, above all else. User Manual. t: f: Euro ONE User Manual RENDER ALARMS Your security, above all else t: 01642 230695 f: 01642 252399 You ve Made the Right Choice Contents Introduction 1-5 Using EURO Panel with Code or Tag 6-7 Intelligent

More information

M800, M800iD Plus, M1000 and M3000. User's Guide

M800, M800iD Plus, M1000 and M3000. User's Guide M800, M800iD Plus, M1000 and M3000 User's Guide Cooper Security Limited 2005 Every effort has been made to ensure that the contents of this book are correct. However, neither the authors nor Cooper Security

More information

Technical Bulletin Bulletin Number: 2012_02 Released: 1 st May 2012

Technical Bulletin Bulletin Number: 2012_02 Released: 1 st May 2012 RX / QX V4.51 and PX V5.00 UTC Climate, Controls and Security Systems is pleased to announce the release of Version 4.51 for the RX / QX (Grade 2) control panels, and Version 5.00 for the PX (Grade 3)

More information

EURO 46 User Manual. For use with EURO 46 (version 9.1 or above) RINS1531-2

EURO 46 User Manual. For use with EURO 46 (version 9.1 or above) RINS1531-2 EURO 46 User Manual For use with EURO 46 (version 9.1 or above) RINS1531-2 Contents Introduction 1 Using EURO Panel with Code or Tag 7-9 Intelligent Setting 13 Silencing the Alarm 20 Setting Individual

More information

EURO 46 V10 User Manual

EURO 46 V10 User Manual EURO 46 V10 User Manual PD6662:2010+IA501:2015 EN50131-1:2008+A1:2009 EN50131-3:2009 Security Grade (SG) 3 - Large Security Grade (SG) 2 - Small Environmental Class (EC) II Software Version >10 RINS1943-1

More information

EURO 46 APP. User Manual. Connect to your home or business from anywhere in the world. Software version 2.1 RINS1840-2

EURO 46 APP. User Manual. Connect to your home or business from anywhere in the world. Software version 2.1 RINS1840-2 EURO 46 APP User Manual Connect to your home or business from anywhere in the world. Software version 2.1 RINS1840-2 Contents Two Way Wireless High Security 3 User Friendly Keyfobs 4 User Automation Outputs

More information

USER GUIDE HARDWIRED CONTROL PANELS

USER GUIDE HARDWIRED CONTROL PANELS USER GUIDE HARDWIRED CONTROL PANELS Scantronic Contents 1. Introduction... 3 The Alarm System... 3 The Keypads... 3 The 725r Remote Setting Device... 6 About This Guide... 6 2. Everyday Operation... 7

More information

Warning: Mains voltages are present inside control unit. No user serviceable parts inside.

Warning: Mains voltages are present inside control unit. No user serviceable parts inside. Eaton s Security Business. 2014 IN NO EVENT WILL EATON S SECURITY BUSINESS BE LIABLE FOR ANY SPECIAL, CONSEQUENTIAL, OR INDIRECT LOSS OR DAMAGE, INCIDENTAL DAMAGES, STATUTORY DAMAGES, EXEMPLARY DAMAGES,

More information

TECHNICAL BULLETIN No: 0040

TECHNICAL BULLETIN No: 0040 National Security Inspectorate Sentinel House, 5 Reform Road, Maidenhead, SL6 8BY E: nsi@nsi.org.uk W: nsi.org.uk Dated: 12 October 2017 To: 1. All NSI NACOSS Gold and System Silver Companies 2. Applicant

More information

ELT-KLED EliteSuite LED Keypad Installation Manual

ELT-KLED EliteSuite LED Keypad Installation Manual ELT-KLED EliteSuite LED Keypad Installation Manual ELT-KLED EliteSuite Installation Manual PUBLICATION INFORMATION First Publication Draft Document Release Only Updated fire zone information Second Publication

More information

PYRONIX LIMITED, Pyronix House, Braithwell Way, Hellaby Rotherham South Yorkshire S66 8QY England

PYRONIX LIMITED, Pyronix House, Braithwell Way, Hellaby Rotherham South Yorkshire S66 8QY England PYRONIX LIMITED, Pyronix House, Braithwell Way, Hellaby Rotherham South Yorkshire S66 8QY England Tel: 01709 700100 Fax: 01709 701042 INT'L Tel: +44 1709 700100 INT'L Fax: +44 1709 701042 WARRANTY This

More information

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand 5 Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd Operating Guide Proudly Designed and Manufactured in New Zealand About your Alarm Controller Thank you for choosing to protect your premises

More information

Summary of changes between PD 6662:2010 and PD 6662:2017 a guide

Summary of changes between PD 6662:2010 and PD 6662:2017 a guide Summary of changes between PD 6662:2010 and PD 6662:2017 a guide October 2017 For other information please contact: British Security Industry Association t: 01905 342 020 e: info@bsia.co.uk www.bsia.co.uk

More information

Galaxy Flex V3. User Guide. Honeywell Security. This user manual is located at

Galaxy Flex V3. User Guide. Honeywell Security. This user manual is located at Galaxy Flex V3 User Guide Honeywell Security This user manual is located at www.eaglesecuritysolutions.co.uk Contents Introduction... 5 Controlling your alarm system... 6 Users... 6 Panel control... 6

More information

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL IMPORTANT: Please note the Sterling 10 LCD keypad is not compatible for use with the Sterling 10 ICON keypad. RINS1413-1 Pyronix

More information

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand 6 Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd Operating Guide 1 Proudly Designed and Manufactured in New Zealand CONTENTS Page No. INTRODUCTION 3 About your Alarm 3 OPERATING YOUR

More information

INTRUDER ALARM FOR BUSINESS SECURITY

INTRUDER ALARM FOR BUSINESS SECURITY INTRUDER ALARM FOR BUSINESS SECURITY WELCOME PACK THANK YOU FOR CHOOSING ADT Thank you for choosing us to help protect your business and employees. Please take the time to read your Welcome Pack carefully

More information

Intruder alarm system Operating Instructions

Intruder alarm system Operating Instructions Intruder alarm system Operating Instructions 0 2 3 4 5 6 7 8 9 CHIME OMIT RESET PROG SET S Power 0 2 3 5 6 7 8 Chime Omit Prog 4 9 Set AccentaG3 mini Servicing organisation details Servicing organisation

More information

User Guide. Contents. About this guide. i-on Style Security System

User Guide. Contents. About this guide. i-on Style Security System i-on Style Security System User Guide Contents About this guide.... 1 About i-on Style... 2 System components.... 2 Control unit... 2 Detectors... 2 External sirens... 3 Remote controls... 3 HUA transmitters...

More information

USER GUIDE HARDWIRED CONTROL PANELS

USER GUIDE HARDWIRED CONTROL PANELS USER GUIDE HARDWIRED CONTROL PANELS Contents 1. Introduction... 3 The Alarm System... 3 The Keypads... 3 The 725r Telecommand (Remote Setting Device)... 5 About This Guide... 5 2. Everyday Operation...

More information

Engineer Reference. EN :2006+A1:2009 EN :2009 EN :2008 EN :2005+A1:2008 Security Grade 2 Environmental Class II

Engineer Reference. EN :2006+A1:2009 EN :2009 EN :2008 EN :2005+A1:2008 Security Grade 2 Environmental Class II EN50131-1:2006+A1:2009 EN50131-3:2009 EN50131-6:2008 EN50131-5-3:2005+A1:2008 Security Grade 2 Environmental Class II Engineer Reference INTERNAL SIREN WARNING The Enforcer 32-WE control panel contains

More information

Scantronic Leading the way in security

Scantronic Leading the way in security USER GUIDE (16 ZONE) HARDWIRED CONTROL PANEL Scantronic Leading the way in security Contents 1. Introduction 3 The 9800+ (16 zone) System... 3 The Keypad... 3 About This Guide... 5 2. Everyday Operation

More information

8 plus and16 plus. User s Guide * # ent. esc GALAXY 16+ V2.XX TUE 30 JUN. IU ZST 962 Issue 2. A u B u

8 plus and16 plus. User s Guide * # ent. esc GALAXY 16+ V2.XX TUE 30 JUN. IU ZST 962 Issue 2. A u B u 8 plus and16 plus User s Guide GALAXY 16+ V2.XX 06.22 TUE 30 JUN 1 2 3 4 5 6 7 8 9 0 * # A u B u ent esc IU1-0018 ZST 962 Issue 2 Contents INTRODUCTION... 1 Glossary of Terms... 3 KEYPAD INFORMATION...

More information

Wireless Keypads LKP(E)S8M Series

Wireless Keypads LKP(E)S8M Series Wireless Keypads LKP(E)S8M Series User manual Contents Congratulations on your purchase of this Honeywell wireless keypad. To make the best out of your equipment we advise you to read this manual carefully.

More information

JA-63 Profi User manual

JA-63 Profi User manual JA-63 Profi User manual Contents: 1 Limited warranty... 2 2 Indicators... 3 3 Controlling the system... 4 3.1 Arming... 5 3.2 Disarming... 6 3.3 Panic Alarm... 6 3.4 To stop ALARM... 6 3.5 Home arming...

More information

USER GUIDE HARDWIRED CONTROL PANELS

USER GUIDE HARDWIRED CONTROL PANELS USER GUIDE HARDWIRED CONTROL PANELS Contents 1. Introduction... 3 The Alarm System... 3 The Keypads... 4 The 725r Telecommand (Remote Setting Device)... 5 About This Guide... 5 2. Everyday Operation...

More information

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL 6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL USER MANUAL Protec Fire Detection plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0)

More information

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand 2 Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd Operating Guide Proudly Designed and Manufactured in New Zealand 1 CONTENTS Page No. INTRODUCTION 3 About your Alarm 3 OPERATING YOUR

More information

Input Type: 42: Medical: This is a 24 Hr type input it will activate the external sounder and report a CID event 100.

Input Type: 42: Medical: This is a 24 Hr type input it will activate the external sounder and report a CID event 100. EURO Addendum VERSION 7.1 - New Features: Version 7.1 software is now available for the Euro 46, 76, 162, and 280. New Input Types: Input Type 29: Interior: This will work the same as an Intruder type

More information

i on Compact Security System

i on Compact Security System i on Compact Security System Administration and User Manual Issue 1 Control unit software version 5.03 Eaton 2017 The information, recommendations, descriptions and safety notations in this document are

More information

HARDWIRED CONTROL PANELS

HARDWIRED CONTROL PANELS USER GUIDE 9651 HARDWIRED CONTROL PANELS Contents 1. Introduction...3 The Alarm System...3 The Keypad...3 About This Guide...5 2. Everyday Operation...6 How Do I Know if the System is Working?...6 Setting

More information

Security Systems and Alarms Inspection Board. Code of Practice For Scaffold Alarm Systems

Security Systems and Alarms Inspection Board. Code of Practice For Scaffold Alarm Systems Security Systems and Alarms Inspection Board Code of Practice For Scaffold Alarm Systems Issue: 6 April 2014 Authorised by: G C Tate Position: Chief Executive Signature: Date: 14 April 2014 Uncontrolled

More information

ATS2000/3000/4000/4500 Control Panel. Programming guide

ATS2000/3000/4000/4500 Control Panel. Programming guide ATS2000/3000/4000/4500 Control Panel Programming guide Version 2.01 (SR_F), June 2004 Aritech is a GE Interlogix brand. www.aritech.com Copyright (c) 2003 GE Interlogix B.V.. All rights reserved. GE Interlogix

More information

Accenta/Optima. User Guide. UK Security Panels. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number:

Accenta/Optima. User Guide. UK Security Panels. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number: Accenta/Optima User Guide ZONE 1 2 3 4 5 6 7 8 9 Chime Omit Prog PA 0 1 2 3 4 5 6 7 8 9 CHIME OMIT RESET PROG SET Accenta + TA PA DAY POWER PA! " # $ % & 0 1 2 3 5 6 7 8 Chime Omit Reset Prog 4 9 Set PA

More information

User Manual. PIEZO WARNING The Wireless Alarm contains a loud siren, please be aware of this after an activation

User Manual. PIEZO WARNING The Wireless Alarm contains a loud siren, please be aware of this after an activation User Manual RINS1902-2 EN50131-1:2006+A1:2009 EN50131-3:2009 EN50131-6:2008 EN50131-5-3:2005+A1:2008 PD6662: 2010+IA:2015 Alarm Panel Time 10:09 c Software Version >10 SMS CHARGES If you re using SMS text

More information

3 User s settings. 3.3 Internal clock setting

3 User s settings. 3.3 Internal clock setting 2.9 Subsystem arming In a large building a sub control panel can be enrolled to the JA-63. The subsystem reports all alarms and failures to the main system. The installer can program if the systems will

More information

Property of Monitronics Inc

Property of Monitronics Inc Enter Program Press CODE key + * + 2468 + 1 (also try 2121) Installer Options Move to location Program location Exit Program Default Panel Hex Program Code + * + Installer Code + 1 = Enter Programming

More information

Wireless Alarm System Extended User Guide. Alarm Panel Time 10:09 c

Wireless Alarm System Extended User Guide. Alarm Panel Time 10:09 c Wireless Alarm System Extended User Guide Alarm Panel Time 10:09 c Contents Introduction 5 ProControl+ 7 Setting Devices 8 The Wireless Panel Keypad and Additional Keypads 8 Proximity Tag Readers 8 Internal

More information

USER MANUAL CEF AP28 CONTROL PANEL

USER MANUAL CEF AP28 CONTROL PANEL USER MANUAL CEF AP28 CONTROL PANEL AP28 WARNINGS This product has mains voltage present within the housing. Please take the necessary precautions in not allowing any liquid to spill on or into the housing.

More information

Summary of Keypad Main User Commands

Summary of Keypad Main User Commands User Manual Summary of Keypad Main User Commands Full Set Code > Part Set Code > System Unset Silence an Alarm Partition Full Set Partition Part Set Code> Code> Code > > Partition No. > Code > > Partition

More information

2000 Series. Program Entry Guide. Control Panels

2000 Series. Program Entry Guide. Control Panels 2000 Series EN Program Entry Guide Control Panels 2000 Series Program Entry Guide About This Manual EN 2 About This Manual This guide describes the programming parameters available to the 2000 Series Control

More information

Scantronic Leading the way in security

Scantronic Leading the way in security USER GUIDE 808 HARDWIRED CONTROL PANEL Scantronic Leading the way in security Contents 1. Introduction... 3 The 808 System... 3 Using the Keypad... 4 About This Guide... 5 2. Everyday Operation... 6 Setting

More information

Control Panel. Operators Manual TO SUIT AS216 KEYPAD. AS216-OM-6.2. Advanced Digital Controls

Control Panel. Operators Manual TO SUIT AS216 KEYPAD.   AS216-OM-6.2. Advanced Digital Controls Control Panel Operators Manual TO SUIT AS216 KEYPAD AS216-OM-6.2 Ultra-16 Control Panel AS216 OPERATORS MANUAL Copyright 2002 by NZ Ltd Auckland, New Zealand Document Part Number: This document is provided

More information

Destiny Destiny Owners Manual

Destiny Destiny Owners Manual Destiny 4100 Destiny 4100 Owners Manual TABLE OF CONTENTS INTRODUCTION Control Panel...3 Detection Devices...3 Telephone Keypads...3 GLOSSARY... 4-5 LOCAL PHONE ACCESS Using Your Telephones As Keypads...6

More information

Elite S Version 8-16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite S Version 8-16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand 9 Elite S Version 8-16 Zone Controller Arrowhead Alarm Products Ltd Operating Guide Proudly Designed and Manufactured in New Zealand 1 CONTENTS Page No. INTRODUCTION About your Alarm 3 3 OPERATING YOUR

More information

GRADESHIFT UDL INSTRUCTION MANUAL 2.5 APPENDIX

GRADESHIFT UDL INSTRUCTION MANUAL 2.5 APPENDIX GRADESHIFT UDL INSTRUCTION MANUAL 2.5 APPENDIX GradeShift UDL Instruction Manual 2.5 Appendix 2.5 APPENDIX SPECIFICATIONS Dimensions 21 mm (h), 132mm (w), 94mm (d) Weight 140g including NVM and SIM Temperature

More information

See the table on the following Page for full descriptions of each Pin Type.

See the table on the following Page for full descriptions of each Pin Type. 8 Pin Comms-22-1 8 Pin Comms Task Format IMPORTANT NOTES: Hardware Compatability. The 8 Pin Comms Task can only be used in Type 2 (CE) Control Module Hardware. 22. Firmware Compatablility. INTRODUCTION.

More information

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom CC880/LP880, SC8016 EN Operators Guide Solution-16, Solution-16 Safecom CC880/LP880, SC8016 Operators Guide EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch

More information

User s Information Guide R2A

User s Information Guide R2A Pi HSC505 Home Security Controller User s Information Guide R2A Page 1 of 15 of its development program. 1This document and product are copyrighted and all rights are reserved. Introduction Convention

More information

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions TS400 & TS410 Intruder Alarm Control Panels Operating Instructions Zone Location Home Set Chime 1 Armed / Omitted 2 Armed / Omitted 3 Armed / Omitted 4 Armed / Omitted 5 Armed / Omitted F. Exit Always

More information

Wireless security products

Wireless security products Wireless security products ABOUT FM Established in 1989 we design and manufacture wireless alarm products for a diverse range of specialist security applications. Our products include Wireless alarm systems,

More information

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ READY ARMED READY 1 OFF 7 INSTANT READY 2 AWAY 8 CODE 6BYPASS 9 CHIME 9,67$% &RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ 8VHU*XLGH ARMED READY 1 OFF 2 AWAY 3 STAY 4 MAX 5 TEST 6 BYPASS

More information

TS2500. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT ESC. Setting the System. Unsetting the System RE SET

TS2500. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT ESC. Setting the System. Unsetting the System RE SET E n t er y ou r pa s s c o de X X X X th en l ea v e th e p r o tec t e d a re a. G o dir e ct ly to t h e k e yp ad an d en te r y ou r p as s c o d e X X X X. E n t er y ou r pa s s c o de X X X X f

More information

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation The most user friendly Contents Section 1 Overview of System 1.1 Kit Contents 1.2 Tools Required 1.3 System Features Security Alarm System L S 4 0 0 Section 2 Planning your Installation 2.1 Location of

More information

Master User Guide Premier Elite Series

Master User Guide Premier Elite Series Master User Guide Premier Elite Series INS177-9 Overview Premier Elite Series Master User Guide Contents 1. Overview... 5 Introduction... 5 Keypads... 7 Emergency Keys... 8 The Quick Arm Keys... 9 Keypad

More information

Intruder alarm system Operating Instructions

Intruder alarm system Operating Instructions Intruder alarm system Operating Instructions 1 2 3 4 5 6 TA PA ZONE Learn Error AccentaG3 mini Servicing organisation details Servicing organisation (Installer) name: Telephone number: Date of installation:

More information

Introduction. When using an LED keypad for Abacus 6P (or some older Abacus panels) refer to the LED Operator instructions guide (Part No. Y6055).

Introduction. When using an LED keypad for Abacus 6P (or some older Abacus panels) refer to the LED Operator instructions guide (Part No. Y6055). Introduction The Abacus range of intruder alarm panels are manufactured by Detection Systems, using advanced microprocessor technology, this allowing greater flexibility and ease of use. Whilst great care

More information

Wireless Keypad GKP-S8M

Wireless Keypad GKP-S8M Wireless Keypad GKP-S8M User manual Contents Congratulations on your purchase of this Honeywell wireless keypad. To make the best out of your equipment we advise you to read this manual carefully. This

More information

BURGLAR ALARM PANEL BS-468

BURGLAR ALARM PANEL BS-468 BURGLAR ALARM PANEL BS-468 Contents 1. Description... 3 2. Instructions for the user... 4 2.1Basic operations... 4 Complete system.... 4 Split system.... 4 2.2 Armed system indication... 5 2.3 Advanced

More information

Control/Communicator Installation Manual

Control/Communicator Installation Manual DAS NETWORX NX-12 Control/Communicator Installation Manual General Description...2 Ordering Information...2 Option Definitions...3 Programming the LED Code Pads...5 Programming the NX-12...9 Types of Programming

More information

Protégé EliteSuite Eclipse LED Keypad Installation Manual ELT-KLES

Protégé EliteSuite Eclipse LED Keypad Installation Manual ELT-KLES Protégé EliteSuite Eclipse LED Keypad Installation Manual ELT-KLES The specifications and descriptions of products and services contained in this manual were correct at the time of printing. Integrated

More information

Sentient. Downloader Manual D4854

Sentient. Downloader Manual D4854 Sentient Downloader Manual D4854 Dycon Ltd Tel: +44 (0)1443 471 060 Fax: +44 (0)1443 479 374 Cwm Cynon Business Park Mountain Ash CF45 4ER - UK www.dyconsecurity.com sales@dyconsecurity.com TABLE OF CONTENTS

More information

Ultra-8D. ControlPanel. Operators Manual. Advanced DigitalControls CP108-0M-V1

Ultra-8D. ControlPanel. Operators Manual. Advanced DigitalControls CP108-0M-V1 Ultra-8D ControlPanel Operators Manual Advanced DigitalControls CP108-0M-V1 ULTRA-8D CONTROL PANEL AS108 OPERATORS MANUAL Copyright 2001 by Advanced Digital Controls NZ Ltd Auckland, New Zealand Document

More information

PROGRAMMING PROCEDURES (Table 3)

PROGRAMMING PROCEDURES (Table 3) CONDOPLEX 2600/2600A/2700 Suite Panel User Manual Document Version 8.4 Oct 19, 1998 Condoplex 1998 PROGRAMMING PROCEDURES (Table 3) FUNCTION PRESS KEYPAD DISPLAY Delete user code or duress code. 0 (hold)

More information

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ 9,67$)% &RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ 8VHU*XLGH FIRE FIRE * PULL K3522 3/99 TABLE OF CONTENTS SYSTEM OVERVIEW...4 General...4 A Partitioned System...4 Zones...5 Fire

More information

Challenger Series Users Manual

Challenger Series Users Manual Challenger Series Users Manual P/N MAUSER-TS1016 05 20AUG15 Copyright Trademarks and patents Manufacturer 2015 UTC Fire & Security Australia Pty Ltd. All rights reserved. The Challenger name and logo are

More information

Version 1.03 January-2002 USER S MANUAL

Version 1.03 January-2002 USER S MANUAL Version 1.03 January-2002 1 USER S MANUAL 2 Version 1.03 January-2002 System Details CUSTOMER:...... PHONE:... FAX:... INSTALLED BY:...... PHONE:... FAX:... MAINTENANCE & SERVICE:...... PHONE:... FAX:...

More information

Property of Monitronics Inc

Property of Monitronics Inc Enter Program Program Location 1. Hold 8 key for 3 seconds, keypad will beep 2. Enter 4 5 6 7 8 9, display should show dash on display 1. Press [B/A] key display will show 3 dashs 2. Enter 3-digit location

More information

EC-P Zone Intruder Alarm System

EC-P Zone Intruder Alarm System EC-P10 10-20 Zone Intruder Alarm System Installation Manual Contents 1. System Overview... 4 System Configuration... 4 Control Panel... 5 Remote Keypads... 5 EC-LED Remote Keypad... 5 EC-LCD Remote Keypad...

More information

A guide to the changes between BS 8418:2010 and BS 8418:2015

A guide to the changes between BS 8418:2010 and BS 8418:2015 A guide to the changes between BS 8418:2010 and BS 8418:2015 March 2016 For other information please contact: British Security Industry Association t: 0845 389 3889 e: info@bsia.co.uk www.bsia.co.uk Form

More information

AXI LED USER MANUAL (REV. 1.0)

AXI LED USER MANUAL (REV. 1.0) Security & Home Automation System AXI LED USER MANUAL (REV. 1.0) CONTENTS PREFACE FEATURES LED KEYPAD OUTLOOK 1.0 LIGHT INDICATION 1 2 4 6 CHAPTER 1: ALARM SYSTEM CONTROL 1.0 USING LED KEYPAD 1.0.1 ARMING

More information

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0 M2M Services Ltd. RControl Alarm - Installer Manual V 1.0 Content Content... 2 Wiring the power supply module... 3 Wiring a siren... 3 SMARTEnroll self-learning zones... 3 Wireless keyfobs... 3 Supported

More information

Sync. Smart Home Alarm

Sync. Smart Home Alarm Sync. Smart Home Alarm Installation Manual IA-30 IA-320 IA-330 IA-340 Thank you for choosing the Yale Sync Smart Home Alarm. This simple to install system has been designed with the user in mind, just

More information

U ser's Guide PC6010

U ser's Guide PC6010 User's Guide PC6010 Quick Reference Guide This manual is for Basic and Advanced users. Each of these types of user can access a different set of functions. The and symbols next to the title of each procedure

More information

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...

More information

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160 All-In-One Wireless Security System V3.2 Programming Guide Model # MG6130 / MG6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com

More information

2GIG GC3 Security & Automation System. Fingertip Guide

2GIG GC3 Security & Automation System. Fingertip Guide 2GIG GC3 Security & Automation System Fingertip Guide Copyright 2015 Nortek Security & Control LLC. All Rights Reserved. U.S. Patent D727,857. Australian Patent No. 357098. Additional Patents Pending.

More information

Comfort Applications Manual

Comfort Applications Manual Comfort Applications Manual Comfort This page intentionally left blank. Security/Automation Integration SECURITY / AUTOMATION INTEGRATION. Automatically Switch off appliances when system is armed. Programming

More information

Solution Ultima Series Operators Manual ISSUE 1.00

Solution Ultima Series Operators Manual ISSUE 1.00 Solution Ultima Series Operators Manual ISSUE 1.00 Solution Ultima Series Operators Manual Copyright 1998 by, SYDNEY, AUSTRALIA Document Part Number MA488O DOCUMENT ISSUE 1.00 Printed 16 February 1999

More information

CALL FOR A FREE SURVEY

CALL FOR A FREE SURVEY CCTV FIRE & SECURITY SOLUTIONS MADE SAFE CCTV Systems specifically designed and tailored for the commercial CCTV market What is CCTV? Closed-circuit television (CCTV), also known as video surveillance,

More information

PCX 46 App Programming Reference

PCX 46 App Programming Reference 1. Contents Page 1. Contents Page... 2 2. Introduction... 3 2.1 Hybrid Integrated System with Automation Control... 3 2.2 Two-Way Wireless Technology... 3 2.3 User Automation Outputs... 3 2.4 SMS Text

More information

Installation Manual Premier 412/816/832. Issue 10

Installation Manual Premier 412/816/832. Issue 10 Installation Manual Premier // Issue 0 Premier // Installation Manual 5. Operating the System Introduction Before attempting to operate the alarm system ensure you have familiarised yourself with all the

More information

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual WIC-16Z4P WIC-5Z2P Installation & Operation User Manual Page : 1/34 INDEX # Function Page 1 Abort Current Communication and Clear Reporting Queue (*59) 13 2 Abort Current Communications (*59) 10 3 Account

More information

JA-82KRC OASiS Control panel installation manual

JA-82KRC OASiS Control panel installation manual JA-82KRC OASiS Control panel installation manual Installation manual: OASiS security system JA-82KRC 1 / 21 MKH51100 Contents: 1. Control panel architecture...3 1.1. Main features...3 1.1.1. Modes...4

More information

All tested. Easy Series Intrusion Control Panel Making security easy featuring wlsn* * wireless Local SecurityNetwork

All tested. Easy Series Intrusion Control Panel Making security easy featuring wlsn* * wireless Local SecurityNetwork All tested Easy Series Intrusion Control Panel Making security easy featuring wlsn* * wireless Local SecurityNetwork 2 A powerful yet straightforward intrusion control panel A powerful intrusion control

More information

FM4000 ALARM SYSTEM TRAINING MANUAL. FM Electronics Ltd FIRE PANIC ZONES FULL SET PART SET OFF TAMPER SIGNALLING LOW BATTERY ALARM MAINS ON

FM4000 ALARM SYSTEM TRAINING MANUAL. FM Electronics Ltd FIRE PANIC ZONES FULL SET PART SET OFF TAMPER SIGNALLING LOW BATTERY ALARM MAINS ON FM4000 ALARM SYSTEM TRAINING MANUAL ZONES PANIC FIRE FULL SET PART SET OFF TAMPER SIGNALLING LOW BATTERY ALARM MAINS ON FM Electronics Ltd Manufacturer of quality wireless products CI-100 iss8 CONTENTS

More information

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0 User s Guide SUB-MA7240O-0001.OG.Solution40-111.doc Created: 6/05/03 Last Updated: 23/09/03 MA7240AO-0001 Version 1.0 2 Table Of Contents User List...6 Quick Reference..7 Features...7 Keypad User's Guide...8

More information

Advisor Advanced User Guide

Advisor Advanced User Guide Advisor Advanced User Guide P/N 1068996 (EN) REV G ISS 28AUG15 Copyright Trademarks and patents Manufacturer Version Certification 2015 UTC Fire & Security Americas Corporation, Inc. All rights reserved.

More information

9x5x QUICK REFERENCE PROGRAMMING GUIDE

9x5x QUICK REFERENCE PROGRAMMING GUIDE 9x5x QUICK REFERENCE PROGRAMMING GUIDE HARDWIRED CONTROL UNITS 9853, 9752, 9751 Hardwired Control Unit Quick Reference Programming Guide This document applies to control panels using software version 4.x.

More information

GE Security. Challenger V8 & V9. User Manual

GE Security. Challenger V8 & V9. User Manual GE Security Challenger V8 & V9 User Manual Copyright Disclaimer Trademarks and patents Intended use Copyright 2008, GE Security Pty. Ltd.. All rights reserved. This document may not be copied or otherwise

More information

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS) USER MANUAL Protec Fire Detection plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT, ENGLAND +44 (0) 1282 717171 www.protec.co.uk

More information

Security System. User Guide for the LED Command Center

Security System. User Guide for the LED Command Center Security System User Guide for the LED Command Center National Security Systems Inc (800)457-1999 MY SECURITY COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY

More information

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure. Notice The material and instructions covered in this manual have been carefully checked for accuracy and are presumed to be reliable. However, Radionics, Inc. assumes no responsibility for inaccuracies

More information