120 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE.

Size: px
Start display at page:

Download "120 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE."

Transcription

1 00000 (0) 00 PowerMatic Low Energy Power Operator Wiring Instructions 0 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE. REQUIREMENTS: U.L. labeled fire or smoke barrier door assemblies require that the 0VAC, 0Hz power input to the Power Door Operator be supplied through normally closed alarm contacts of the alarm system/alarm panel. All wiring and connections use standard wiring practice conforming with local wiring codes. Power inputs at terminal strip T and at terminal strip JP must be made with copper wire only. Maximum wire size is: AWG at Power Input Terminal s AWG atterminal s JP And JP Note: No power/voltage inputs are to be made to the Door Operator unit except 0VAC, 0Hz (0% %) at terminals HOT and COM of the Power InputTerminal T. Typical field connections for flexible conduit illustrated on page. Power input terminal strip T at terminals Hot and COM must be 0VAC at 0Hz (0% %). Current draw at auxiliary contact JP must not exceed 0.00 amps, for auxiliary devices. GENERAL DATA: Maximum current draw of Door Operator units without peripheral sensors or scanners is. amps when motor is operating,.00 amps in standby. Maximum current draw from auxiliary devices is 0.00 amps (terminals JP and JP ). Fuse F protects the Electronic Control Module and Transformer circuit and is a amp slow blow fuse. Requirements Unit Wiring Control Module Layout and (Input/Output Connections; Functions) Typical Application Point to Point Wiring Diagrams Rotary Switches/ Timer Pots SW Dip Switches Main Board Bracket for Input Power Terminal T Fuse F JP Terminal Timing Belt ELS Board w/ ELS Board Pulley Pinion Timing Pulley ELS Board LED SC PUSH (SC) Speed Control Valve JP Terminal JP Terminal JP Terminal JP Terminal Solenoid Application (REF) /" Power Adjustment Nut Door Calibrate Open Position Door Calibrate Close Position (0)

2 CONCEALED WIRING Thread conduit fitting(s) into backplate as shown. A second conduit fitting is required for low voltage control wiring. CHECK LOCAL CODES. Pull conduit out of header and attach to conduit fittings before mounting Operator to door frame. Attach incoming ground wire to backplate with ground screw as illustrated below. (Green) Ground Screw Conduit by Others (from top) Low Voltage Control Wiring Incoming Power T Power Input Terminal Bracket SURFACE WIRING An optional bracket is provided for use with surface wiring. Remove the two cable clamps screws and slip the bracket under the cable clamps. Push the cable clamp screw through the bracket holes and tighten. ½ conduit fittings can now be installed on the bracket. Cable Clamps Optional Bracket (for surface wiring) Ground Lead Power Leads INSTALLER / USER INFORMATION Input Power Terminal Maximum wire size AWG at terminals HOT and COM. Terminals through are factory wired using AWG wire. Ground Wire Connection Ground wire must be secured to backplate under head of (green) ground screw nearest to T Power Input Terminal bracket. Screw labeled GND. Terminal Description Fuse F* COM Common power lead HOT Hot power lead Fuse connection Hot connection to PC board JP and to hot primary side of 0V / V transformer. Fuse connection Common connection to PC board JP and common primary side of 0V / V transformer. to HOT COM Left Hand Double Lever, Push Side Right Hand Slide Track, Pull Side COM HOT Fuse F* Right Hand Double Lever, Push Side Left Hand Slide Track, Pull Side (0)

3 SW Rotary Switch/Timer Pot SW Rotary Switch/Timer Pot SW Rotary Switch/Timer Pot SW Dip Switches JP Terminal JP Terminal SW Rotary Switch/Timer Pot JP Terminal Fuse F. amp, AG SloBlo G E M G H V L G L MOTOR/SOLENOID JP JP EXSOL DLY Relay K M. DLY Relay K 00/00 SERIES DOOR OPERATOR 0000 REV A MADE IN USA SW RES RES JP VAC Relay K Relay K GND V NO CO NC NO CO NC JP JP 0 0/0 RES AUX GND INV OUTV GND RFT GND AUX GND PDET GND AUX JP Terminal Electronic Control Module (Main PC Board) JP Terminal Maximum wire size AWG. For signaling only, do not make power input connections. TERMINAL D E S CRIPTION 0/0 Override Open This terminal has two possible functions that can be used together or separately.. Smoke Ventilation Door or Blow Open Door Upon initiation of a closed signal from a fire/ smoke alarm panel, door will open and remain open until signal is terminated. Use with any JP ground.. Alarm Delay (0 second or 0 second time period) Time is set with dip switch SW. (OFF = 0 second delay, ON = 0 second delay) Use with any JP ground. RES This is not an active contact. AUX GND Ground INV OUTV GND Ground Auxiliary This is one of two secondary initiating switch contacts (JP 0 is the other.) For most applications it is equivalent to AUX JP. For Vestibule Function use, it is the contact for a switch located within the vestibule. Use with any JP ground. In Vestibule Used for Vestibule Function. This contact must be connected to the JP terminal from another unit to receive an initiating signal. The signal is then programed to initiate the unit by setting the VEST DLY rotary switch/timer pot of the receiving unit. Use this contact with any JP ground. Out Vestibule Used for Vestibule Function. This contact must be connecter to terminal JP of another unit to send an initiating signal. Use with any JP ground. RFT Maintain Hold Open With the unit s Position Slide Switch in the ON position, a signal will open the door and maintain an indefinite hold open until a second signal releases the door from hold open. Use with any JP ground. This feature recommended for Power Operator Function. If using with the Power Assist Function, consult factory. GND Ground 0 AUX Auxiliary Same as JP / AUX above. GND Ground PDET GND Ground AUX Presence Detector Permits wiring of a presence detector to prevent a closed door from opening or a door that is fully open from closing. Use with any JP ground. Auxiliary Primary initiating switch contact. Initiates door power cycle. For Vestibule Function, the switch at outside of vestibule is connected to this terminal. (Outside switch to outside unit s JP. Inside switch to inside unit s JP ). Use with any JP ground (0)

4 JP Terminal Maximum wire size AWG. TERMINAL D E S CRIPTION GND Ground VDC output to a maximum current draw of 0.00 amps. Use with ground terminal JP NO Solenoid Control (Relay Contact Only) Normally open contact that is switched by Relay K (on main board) to close. Relay K will remain switched for a period set by SW EXSOL DLY rotary switch / timer pot. Use with terminal JP CO. Coordinate use of this terminal with delayed start of motor using rotary timer pot SW M CO Solenoid Control (Relay Contact Only) Common contact for use with terminals JP NO and JP NC. NC NO Solenoid Control (Relay Contact Only) Normally closed contact that is switched by Relay K (on main board) to open. Relay K will remain switched for a period set by SW EXSOL DLY rotary switch / timer pot. Use with terminal JP CO. Coordinate use of this terminal with delayed start of motor using rotary timer pot SW M DLY. Alarm Delay (Switching Contact Only) Normally open contact that is switched by relay K (on main board) to close. Relay K will remain switched for a period set by Dip Switch SW (OFF = 0 second delay; ON = 0 second delay). Use with terminal JP CO. CO Alarm Delay (Switching Contact Only) Common contact for use with terminals JP NO and JP NC. NC Alarm Delay (Switching Contact Only) Normally closed contact that is switched by relay K (on main board) to open. Relay K will remain switched for a period set by Dip Switch SW (OFF = 0 second delay; ON = 0 second delay). Use with terminal JP CO. Main Board Switches DIP SWITCHES (MAIN BOARD) DESCRIPTION Door Operator Function Switch OFF position selects the Power Operator Function. On position sets the Power Assist Function. Alarm System Delay Timer This switch is used in conjunction with terminal Jp, 0/0 for optional function. (OFF = 0 second delay, ON = 0 second delay). RES DIAGNOSTIC USE. FOR FACTORY AUTHORIZED PERSONAL. RES DIAGNOSTIC USE. FOR FACTORY AUTHORIZED PERSONAL. ROTARY SWITCHES SW M DLY SW EXSOL DLY SW VEST DLY SW CL/AS DLY DESCRIPTION This rotary switch or timer pot sets the length of delay for motor start up to allow for unlocking of exit devices, electric strikes, magnetic locks, See Chart for delay times. This rotary switch or timer pot sets the length of time that a solenoid remains either energized or deenergized to allow unlocking. Used in conjunction with terminals JP, JP, JP. See Chart for length of time. This switch or timer pot sets the length of time between receipt of the In Vestibule signal (terminal JP ) and motor startup. See Chart for delay times. Controls either one of two function times: Power Operator Function Sets length of time door holds open at fully taught open position. Power Assist Function Sets length of time motor and pump will operate to reduce opening force. When time elapses, the door force reverts to full opening spring force set. Chart SW, M DLY Length of Time Settings (Seconds) Chart SW, EXSOL DLY Length of Time Settings (Seconds) Chart SW, VEST DLY Length of Time (Seconds) 0 0 Settings 0 Chart SW, CL/AS DLY Length of Time Settings (Seconds) (0)

5 JP Terminal Factory Wired Connections. TERMINAL D E S CRIPTION L G L White Wire High side of L Input signal from ELS Board. Detects door motion to open door when door is pushed or pulled in the open direction. Movement of potentiometer on ELS Board signals L input. Black Wire Ground. Common connection for L and L inputs. Blue Wire High side of L Input signal for ELS Board. Detects the Fully Open Position stored in the ELS Board during the teaching mode. V Yellow Wire VDC. This terminal is used to supply power to the ELS Board. H G M E G Violet Wire Hold Open contact of OFF ON H/O switch assembly. White Wire Ground. Common contact of OFF ON H/O switch assembly. Orange Wire ON contact of OFF ON H/O switch assembly. Red Wire Emergency Hold Open Release. This contact is used in conjunction with the ELS board to close the door immediately at any point of door opening once an obstruction on opening is encountered. It is used with terminal JP G. Black Wire Ground. Use with terminal Jp E for Emergency Hold Open Release. JP Terminal Factory Wired Connections. TERMINAL D E S CRIPTION NEU Common 0V connection to Input Power Terminal. HOT Hot 0V connection to Input Power Terminal. GND Ground connection secured to backplate under head of (green) ground screw that is located under Main PC Board. Screw Labeled GND VAC From secondary of 0V / V transformer. VAC From secondary of 0V / V transformer. JP Terminal Factory Wired Connections. TERMINAL MOTOR SOLENOID Motor Connection. Solenoid coil connection. D E S CRIPTION (0)

6 0/0 RES AUX GND INV OUTV GND RFT GND AUX GND PDET GND AUX 0/0 RES AUX GND INV OUTV GND RFT GND AUX GND PDET GND AUX Standard Function with Switches Doors are normally closed. Activating either switch will open both doors. Door will close after hold open time delay has elapsed. G E M G H V L G L MOTOR/SOLENOID JP JP JP VAC SW RES RES JP 0 0 GND V NO CO NC NO CO NC JP JP Door Door RELAY CONTACTS FOR ELECTRIC STRIKE. ELECTRIC LATCH RETRACT EXIT DEVICE, MAGNETIC LOCK, ETC. See Note. Note : If product being connected does not have an integrated diode, one must be installed across contracts to protect relays. Suggested diode is N00 or equivalent. See pages for illustration of use.. Power input Door Operator Unit is at 0VAC 0Hz.. Current draw must not exceed 0.00 amps at terminal JP (0)

7 JP JP VAC within the corridor will open the outside door only. Vestibule Function 00/00 SERIES DOOR OPERATOR SW JP 0000 REV A MADE IN USA Doors are normally closed. RES RES Activating outside door switch will open the outside G E M G H V L G L MOTOR/SOLENOID door. After the vestibule time delay has elapsed, a signal will be sent to the inside door which will open. Activating the inside door switch will open the inside door. After the vestibule time delay has elapsed, a signal will be sent to the outside door which will open. Both doors will close when the hold open time delay has elapsed. Activating the optional inside door switch located within the corridor will open the inside door only. This door will reclose after the hold open delay has elapsed. Activating the optional outside door switch located This door will reclose after the hold open delay has elapsed. GND V NO CO NC NO CO NC JP JP 0 0/0 RES AUX GND INV OUTV GND RFT GND AUX GND PDET GND AUX Inside Switch INSIDE DOOR All Switches are either Wall Switches, Card Readers, Key Switches, RELAY CONTACTS FOR ELECTRIC STRIKE. ELECTRIC LATCH RETRACT EXIT DEVICE, MAGNETIC LOCK, ETC. See Note. Optional Inside Corridor Switch VESTIBULE Optional Outside Corridor Switch G E M G H V L G L MOTOR/SOLENOID JP JP EXSOL DLY M. DLY 00/00 SERIES DOOR OPERATOR 0000 REV A MADE IN USA SW RES RES JP VAC JP 0 0/0 RES AUX GND INV OUTV GND RFT GND AUX GND PDET GND AUX Outside Switch OUTSIDE DOOR Note : If product being connected does not have an integrated diode, one must be installed across contracts to protect relays. Suggested diode is N00 or equivalent. See pages for illustration of use. GND V NO CO NC NO CO NC RELAY CONTACTS FOR ELECTRIC STRIKE. ELECTRIC LATCH RETRACT EXIT DEVICE, MAGNETIC LOCK, ETC. See Note. JP. Power input Door Operator Unit is at 0VAC 0Hz.. Current draw must not exceed 0.00 amps at terminal Jp (0)

8 JP. Power input Door Operator Unit is at 0VAC 0Hz.. Current draw must not exceed 0.00 amps at terminal JP. RELAY CONTACTS FOR ELECTRIC STRIKE. ELECTRIC LATCH RETRACT EXIT DEVICE, MAGNETIC LOCK, ETC. See Note. Radio Frequency Function Options GND V NO CO NC NO CO NC JP VAC 0/0 JP RES AUX GND INV OUTV GND RFT GND Option. Door is normally closed. Activating wireless switch or hand held wireless transmitter will open the door. Door will close after hold open delay elapses. Option. Door is normally closed. Activating a wireless switch or hand held wireless transmitter will open the door. Door will remain in indefinite hold open until wireless switch or hand held transmitter is activated a second time causing the door to close. 0 AUX GND PDET GND AUX SW RES RES JP YELLOW OPTION ORANGE BLACK BROWN RED RF RECEIVER BOARD (PART OF OPERATOR UNIT) WIRING FOR STANDARD MOMENTARY HOLD OPEN FUNCTION 0 OPTIONAL SECOND LOW ENERGY POWER OPERATOR YELLOW ORANGE BLACK BROWN RED OPTION RF WIRING FOR RECEIVER TOGGLE / MAIN BOARD TAINED (PART OF HOLD OPEN OPERATOR FUNCTION UNIT) Note : If product being connected does not have an integrated diode, one must be installed across contracts to protect relays. Suggested diode is N00 or equivalent. See pages for illustration of use (0)

9 0/0 RES AUX GND INV OUTV GND RFT GND AUX GND PDET GND AUX Fail Secure Electric Strike VDC Wiring G E M G H V L G L MOTOR/SOLENOID JP JP JP VAC SW RES RES JP 0 GND V NO CO NC NO CO NC JP Diode N00 VDC Electric Strike (fail Secure) Door is normally closed and latched. Activating switch will unlock the electric strike and the door will automatically open. Door will close after hold open time delay has elapsed. The door will remain locked during power failure.. Power input Door Operator Unit is at 0VAC 0Hz.. Current draw must not exceed 0.00 amps at terminal JP (0)

10 0/0 RES AUX GND INV OUTV GND RFT GND AUX GND PDET GND AUX Fail Safe Electric Strike VDC Wiring G E M G H V L G L MOTOR/SOLENOID JP JP JP VAC SW RES RES JP 0 GND V NO CO NC NO CO NC JP Diode N00 VDC Electric Strike (fail Safe) Door is normally closed and latched. Activating switch will unlock the electric strike and the door will automatically open. Door will close after hold open time delay has elapsed. The door will remain unlocked during power failure.. Power input Door Operator Unit is at 0VAC 0Hz.. Current draw must not exceed 0.00 amps at terminal JP (0)

11 0/0 RES AUX GND INV OUTV GND RFT GND AUX GND PDET GND AUX Fail Safe Electromagnetic Lock VDC Wiring G E M G H V L G L MOTOR/SOLENOID JP JP JP VAC SW RES RES JP 0 GND V NO CO NC NO CO NC JP Door is normally closed and latched. Activating switch will unlock the maglock and the door will automatically open. Door will close after hold open time delay has elapsed. The door will unlock during power failure. Diode N00 Note: If Maglock does not have a spike protection, it is recommend that a N00 diode be added across coil. VDC Electromagnetic Lock (Fail Safe). Power input Door Operator Unit is at 0VAC 0Hz.. Current draw must not exceed 0.00 amps at terminal JP (0)

12 0/0 RES AUX GND INV OUTV GND RFT GND AUX GND PDET GND AUX Electric Dogging Exit Device Wiring G E M G H V L G L MOTOR/SOLENOID JP JP JP VAC SW RES RES JP 0 GND V NO CO NC NO CO NC JP ON / OFF Key Switch Diode N00 Door is normally closed and latched. Turning key switch ON will apply power to the exit device. The first depression on the device touchpad will electrically dog the device for push / pull operation. The door will now open automatically when the wall switch is depressed. The device will relatch during a power failure or when the keyswitch is turned off. The exit device allows egress at all times. The exit device allows egress during power failures. Touch Bar Monitor Switch VDC Electric Dogging Exit Device w/ Touch Bar Monitoring (Yale and Corbin Russwin Shown). Power input Door Operator Unit is at 0VAC 0Hz.. Current draw must not exceed 0.00 amps at terminal JP (0)

13 0/0 RES AUX GND INV OUTV GND RFT GND AUX GND PDET GND AUX Electric Latch Retraction Exit Device Wiring G E M G H V L G L MOTOR/SOLENOID JP JP JP VAC SW RES RES JP 0 GND V NO CO NC NO CO NC JP N Controller 0 VAC Door is normally closed and latched. Activating the switch will retract the exit device latchbolt and the operator will open the door. The door will close after the hold open time delay has elapsed. Exit device allows egress at all times. Exit device allows egress during power failure. Yale and Corbin Russwin. Power input Door Operator Unit is at Power Input Terminal (not shown) 0VAC 0Hz.. Yale and Corbin Russwin Shown. Refer to Manufactures wiring instructions for Latch Retraction Devices not shown or contact Norton Technical Service for assistance. Latch Retraction Exit Device (0)

14 0/0 RES AUX GND INV OUTV GND RFT GND AUX GND PDET GND AUX 0/0 RES AUX GND INV OUTV GND RFT GND AUX GND PDET GND AUX Low Energy Power Operator # Electric Latch Retraction Exit Device Wiring (Pair) Yale and Corbin Russwin JP VAC SW RES RES GND V NO CO NC NO CO NC JP JP 0 Door Operator Door Operator 0 JP N Controller 0 VAC Latch Retraction Exit Device # Latch Retraction Exit Device # Doors are normally closed and latched. Activating the switch will retract the exit device latchbolts and the operator will open both doors. The doors will close after the hold open time delay has elapsed. Exit device allows egress at all times. Exit device allows egress during power failure.. Power input Door Operator Unit is at 0VAC 0Hz (0)

15 0/0 RES AUX GND INV OUTV GND RFT GND AUX GND PDET GND AUX Electric Latch Retraction Exit Device Wiring For Smoke Ventilation Blow Open Function Yale and Corbin Russwin G E M G H V L G L MOTOR/SOLENOID JP JP JP VAC SW RES RES JP 0 Fire Alarm System (Dry Contacts Only) C NO GND V NO CO NC NO CO NC JP N Controller 0 VAC Doors are normally closed and latched. Fire Alarm activation will retract the exit device Latchbolt and the Door Operator will open the door. Latch Retraction Exit Device #. Power input Door Operator Unit is at 0VAC 0Hz. The door will remain open until the Fire Alarm System has been reset. The Door Operator s main power input must be wired into the buildings backup power system. Exit device allows egress at all times. Exit device allows egress during power failure. NOTE: This application must be approved by local (AHJ) authority having jurisdiction. ASSA ABLOY 000 Highway East Monroe, NC Tel: () Fax: (00)0 Norton is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright 00, 00 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited (0)

ASSA ABLOY Series Power Operator Installation and Instruction Manual 6060 / Reveal. Adjusting Rod (08-13)

ASSA ABLOY Series Power Operator Installation and Instruction Manual 6060 / Reveal. Adjusting Rod (08-13) 6000 Series Operator Installation and Instruction Manual ASSA ABLOY 6060 / 6070 1 3 5 4 6 2 Item No. Description 1 2 Motor (6000M) Cover (6000COV) 3 4 Control Inverter (6000IN) Supply 24VDC (6000SUP) Reveal

More information

5900 Series X-in Low Energy Power Operator

5900 Series X-in Low Energy Power Operator 5900 Series X-in Low Energy Power Operator INTRODUCTION The Norton 5900 Series X-in is a full-featured, extremely quiet, low energy door operator designed for moderate to high traffic doors. This cost-effective

More information

5600 series. Low Energy Power Operator

5600 series. Low Energy Power Operator 5600 series Introduction The 5600 Series, a member of the POWERMATIC Family of Operators, offers functionality and control at an affordable price. Ideal for retrofit applications, the 5600 Series converts

More information

5900 SERIES Low Energy Power Operator

5900 SERIES Low Energy Power Operator Low Energy Power Operator introduction The Norton 5900 Series is a full-featured, extremely quiet, low energy door operator designed for moderate to high traffic doors. This cost-effective operator is

More information

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F II 1400-2 ACSI 1406-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F INSTALLATION Transformer Model BE31763001 by Basler Electric, Transformer Model 2010028 by Galaxy

More information

LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE

LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE MODIFICATIONS TO: ADAMS RITE ARROW CORBIN RUSSWIN DORMA DOROMATIC MONARCH PRECISION SARGENT VON DUPRIN YALE and more SERIES 1500 EXIT DEVICES CATALOG

More information

7200 Series. Electromechanical Closer/Holder Releasing Devices

7200 Series. Electromechanical Closer/Holder Releasing Devices 7200 Series Electromechanical Closer/Holder Releasing Devices INTRODUCTION The 7200 Series Electromechanical Closer/Holders combine the functions of an electromechanical door holder with the 7700 series

More information

SP-1000X. Panic Device Power Controller Installation Guide. Rev

SP-1000X. Panic Device Power Controller Installation Guide. Rev TM SP-1000X Panic Device Power Controller Installation Guide Rev. 120213 Overview: SP-1000X will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed to handle the high current

More information

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev RPSMLR2 RPSMLR2BB Panic Device Power Controller Installation Guide LISTED Rev. 102715 Overview: RPSMLR2BB, RPSMLR2 will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed

More information

Series. Access Power Controllers. Installation Guide

Series. Access Power Controllers. Installation Guide Series Access Power Controllers Installation Guide Models Include: Maxim11 - Power Supply 1: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Power Supply 2: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Sixteen (16) fuse

More information

Installation Guide for models:

Installation Guide for models: 140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal11F - Power Supply 1: 12VDC @ 3.3 amp or 24VDC @ 3.6 amp. - Power Supply 2: 12VDC @ 3.3 amp

More information

Installation Guide for models:

Installation Guide for models: 140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal3FD - 12VDC @ 4.6 amp or 24VDC @ 5.2 amp. - Sixteen (16) PTC protected power-limited outputs.

More information

RELEASE DEVICE CONTROLS

RELEASE DEVICE CONTROLS RELEASE DEVICE CONTROLS RELEASE DEVICE MODEL C+ INSTALLATION MANUAL UL LISTED CANADIAN LISTED CSFM: 7300-48:00 GENERAL DESCRIPTION: MADE IN THE U.S.A. S/N: The LM0-C+ Release Device/Control Panel is a

More information

DE5300 Delayed Egress System. General Information

DE5300 Delayed Egress System. General Information *911031-00* 911031-00 Wiring and Configuration DE5300 Delayed Egress System Installation Instructions General Information The Von Duprin DE5300 is designed for controlled egress applications when used

More information

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs ACM Series Access Power Controllers with Power Supplies Installation Guide Models Include: AL400ULACM AL600ULACM - 12VDC @ 4 amp - 12VDC or 24VDC @ 6 amp. or 24VDC @ 3 amp - Fused Outputs - Fused Outputs

More information

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

ACM4 Series UL Listed Sub-Assembly Access Power Controllers ACM4 Series UL Listed Sub-Assembly Access Power Controllers Installation Guide Models Include: ACM4 - Four (4) Fuse Protected Outputs ACM4CB - Four (4) PTC Protected Outputs Rev. 051311 More than just

More information

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-3 ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS Features: For use with doors or groups of doors that must interlock with each other to regulate control of accessing one area from another,

More information

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep. Power Supply/Chargers Installation Guide Models Include: eflow4na8-4a @ 12VDC or 24VDC - Eight (8) Fused Outputs eflow6na8-4a @ 12VDC or 24VDC - Eight (8) Fused Outputs eflow102na8-10a @ 12VDC - Eight

More information

An ASSA ABLOY Group brand Series. Electromechanical Closer-Holder Releasing Device

An ASSA ABLOY Group brand Series. Electromechanical Closer-Holder Releasing Device An ASSA ABLOY Group brand 4200 Series Electromechanical Closer-Holder Releasing Device introduction The 4200 Series Electromechanical Closer-Holders combine the functions of an electromechanical door holder

More information

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES POWER SUPPLY AND BATTERY CHARGER AC AND DC STATUS INDICATORS ENOUGH POWER TO SUPPORT UP TO 3 MAGLOCKS OR ELECTRIC STRIKES PLUS REQUIRED

More information

Wiring Instructions (01-09)

Wiring Instructions (01-09) CAUTION Wiring Instructions 0--00-0 (0-0) Power Track Series with Single Point Hold-Open Electromechanical Releasing Device with Multi-Point Hold- Open TO PREVENT ELECTRICAL SHOCK AND EQUIPMENT DAMAGE,

More information

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev. ACM8 & ACM8CB Access Power Controllers Installation Guide Models Include: ACM8 ACM8E - Fused Outputs - Fused Outputs ACM8CBE ACM8CB - PTC Outputs - PTC Outputs Rev. 092503 Overview: These units convert

More information

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep. Power Supply/Chargers Installation Guide Models Include: eflow4na8d - 4A @ 12VDC or 24VDC - Eight (8) PTC Outputs eflow6na8d - 4A @ 12VDC or 24VDC - Eight (8) PTC Outputs eflow102na8d - 10A @ 12VDC - Eight

More information

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors Hinge Edge of Door Hinge Edge of Door Wiring Instructions for the Sargent 0 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector CAUTION: FAILURE TO INSTALL

More information

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION: RELEASE DEVICES MADE IN THE U.S.A. RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION: S/N: The "WPS" World Power Series, Time Delay Release

More information

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE Fire Door Release MODEL AR-D MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs ACM8 Series UL Listed Sub-Assembly Access Power Controllers Installation Guide Models Include: ACM8 - Eight (8) Fuse Protected Outputs ACM8CB - Eight (8) PTC Protected Outputs Rev. 042811 More than just

More information

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction Riser and Point-to-Point Drawings for Standard Access Control Applications Using Maintained Latch Retraction Control or Momentary

More information

Remote Chexit Module (RCM) System. General Information

Remote Chexit Module (RCM) System. General Information *911032-00* 911032-00 Wiring and Configuration Remote Chexit Module (RCM) System Installation Instructions General Information The Von Duprin RCM is designed for controlled egress applications. It meets

More information

EHT/EHTD. Electromechanical Closer-Holder Release Devices

EHT/EHTD. Electromechanical Closer-Holder Release Devices 351 EHT/EHTD Electromechanical Closer-Holder Release Devices Copyright 2003-2009, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Table of Contents Table of Contents Page

More information

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information: RDM LOCK G-1 1400 Series Electromagnetic Lock The patented 1400 Series Electromagnetic Lock is universal for all types of applications, including outdoor use. The innovative design will reduce installation

More information

HARDwired Installation/ Owner s Manual

HARDwired Installation/ Owner s Manual HARDwired Installation/ Owner s Manual Use this manual for circuit - Revision L or higher. For Models:,, and Multi-Door Access Controller Wiegand Compatable --R-- Provides Access Control System to manage

More information

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

SOLID STATE SECURITIES, INC. THE SS90 SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL S S S S S S LISTED L * PATENT PENDING S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT U 99Y9 RESET RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within this manual prior to installing and/or servicing this product. As with all releasing device

More information

Section 1 General Description

Section 1 General Description CX-33 Advanced Logic Relay Installation Instructions Firmware Ver. 2.5 Section 1 General Description The CX-33 is the latest generation multi-purpose logic control. It is designed to be versatile yet user

More information

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL Firefly II Multi Voltage RELEASE DEVICES Firefly II & IIB-MV INSTALLATION MANUAL GENERAL DESCRIPTION: S/N The The Cookson Company Firefly II-MV time delay release devices are designed for use on rolling

More information

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door CAUTION Hinge Edge of Door Wiring Instructions Checkmate Series with Single Point Hold-Open Combination Door Closer-Holder and Releasing Device with or without Integral Smoke Detector INSTALLER: LEAVE

More information

Alarmed Exit Hardware

Alarmed Exit Hardware Copyright 2005, 2007, 2009-2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Contents 540/550 Series Exit Alarm...1 5100 Series Alarmed Exit Lock...2 5800 & 12-5800

More information

EASY-WAVE Trash & Linen Chute System Installation

EASY-WAVE Trash & Linen Chute System Installation EASY-WAVE Trash & Linen Chute System Installation Easy-Wave Trash & Linen Chute System Installation Instructions Introduction REVISED: 25-JAN-18 The Easy-Wave trash & linen chute system is designed to

More information

MODEL B2 INSTALLATION MANUAL

MODEL B2 INSTALLATION MANUAL RELEASE DEVICES GENERAL DESCRIPTION MODEL B2 INSTALLATION MANUAL S/N: The B2 Series Time Delay Release Devices are UL Listed, Canadian Listed, and CSFM Listed for use on rolling doors, single-slide and

More information

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved Fire Guard SARGENT Manufacturing Company 2004, 2007 All rights reserved Fire Guard Table of Contents Features and Additional Fire Opening Devices............................1 2408 Single-Point Hold Open

More information

CX-29. Section 1 General Description. Section 2 Installation. Besam Switching Network & Bi-Directional Door Sequencer Installation Instructions

CX-29. Section 1 General Description. Section 2 Installation. Besam Switching Network & Bi-Directional Door Sequencer Installation Instructions CX-9 550 Timberlea Blvd., Mississauga, ON L4W T7 Telephone: 905-366-3377 Fax: 905-366-3378 Toll-Free: -877-6-3369 Web: www.camdencontrols.com Besam Switching Network & Bi-Directional Door Sequencer Installation

More information

TS93 EMR WITH SMOKE DETECTOR

TS93 EMR WITH SMOKE DETECTOR TS EMR WITH SMOKE GENERAL DESCRIPTION Each TS EMR series unit contains a door closer, hold open electromagnet and smoke detector. The unit can be used as a single installation or as a series of singles

More information

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

THE SS90 SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL S S S S S S OLID TATE ECURITIES, INC S S 90 SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED 99Y9 RESET U L RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

TS93 EMF SERIES. INSPK NO Rev.03/10

TS93 EMF SERIES. INSPK NO Rev.03/10 TS93 EMF SERIES 1 Each hold open (HO) unit contains a door closer and track assembly with hold open solenoid. The unit can be connected directly to a fire control panel. 1) Read the entire instruction

More information

Booster Power Supply Manual

Booster Power Supply Manual Supply Manual DEVELOPED BY COPYRIGHT NOTICE General Signal Building Systems Corporation 6411 Parkland Drive Sarasota, FL 34243 (941) 739-4300 Copyright 1999 General Signal Building Systems Corporation

More information

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

STATUS ALARM ALARM HISTORY POWER HISTORY RESET Instruction Manual Model 1582-70L2 RF Switch June 2011, Rev. D CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL REMOTE ONLINE

More information

MANUAL RESET ALARM RELEASE BOX

MANUAL RESET ALARM RELEASE BOX MANUAL RESET ALARM RELEASE BOX (For 100~240VAC or 24VAC or 24VDC) INSTRUCTION MANUAL WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations: F1! 44487023 These instructions cover the following parts: PS902 Power Supply Installation Instructions! DANGER: To avoid risk of electric shock, turn off AC power before installing or servicing PS902

More information

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL RELEASE DEVICES MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL The LiftMaster Fire Control (LM21-AFC) Release Device/Control Panel is UL/CUL listed normally energized fail-safe device incorporating

More information

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

CM-RQE70A PIR REQUEST TO EXIT DETECTOR Door Activation Devices CM-RQE70A PIR REQUEST TO EXIT DETECTOR THIS PACKAGE INCLUDES (2) #6 x 3/4" Screws (2) 3/16" Wall Plugs (2) MOV's BP7175 1. GENERAL DESCRIPTION Camden CM-RQE70A Request-to-Exit Sensor

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

DS160/DS161 Request To Exit PIR sensors Installation Instructions

DS160/DS161 Request To Exit PIR sensors Installation Instructions DS160/DS161 Request To Exit PIR sensors Installation Instructions 1.0 Description The DS160 is a Passive Infrared Detector (PIR) which is UL Listed as an Access Control Device under the UL 294 Standard.

More information

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE SYSTEM. HANDLE THE EQUIPMENT CAREFULLY.

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE SYSTEM. HANDLE THE EQUIPMENT CAREFULLY. 575 Birch Street, Forestville, CT 06010 Phone (866) 322-1237 Fax (866) 322-1233 WWW.LOCKNETICS. CL-CONTROLLER CL-CONTROLLER UNLIMITED USERS ALLOWED 2000 AUDIT EVENTS SOFTWARE-MANAGED TIME ZONES SOFTWARE-MANAGED

More information

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep. 140 58th St. Brooklyn, NY Power Supply/Chargers Installation Guide Models Include: eflow4n/eflow4nx - 4 amp @ 12VDC or 24VDC eflow4n8/eflow4nx8 eflow4n8d/eflow4nx8d - 4 amp @ 12VDC or 24VDC - 4 amp @ 12VDC

More information

Installation Instructions

Installation Instructions Request-to-Exit Dual Technology Motion Sensor 1048889B November 2005 Copyright 2005, GE Security Inc. Introduction This is the GE Request-to-Exit Dual Technology Motion Sensor for models -W, -B, and -G.

More information

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION: S/N: These Time Delay Release Devices are U.L. Listed, Canadian Listed,

More information

Model 17A00 Expansion Enclosure

Model 17A00 Expansion Enclosure HOME AUTOMATION, INC. Model 17A00 Expansion Enclosure Installation Manual Document Number 17I00-1 Rev A March, 2002 Home Automation, Inc. Model 17A00 Expansion Enclosure Installation Manual Document Number

More information

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone: Cookson Company 1901 South Litchfield Road Goodyear, AZ 85338 Phone: 800-294-4358 www.cooksondoor.com O W N E R S M A N U A L MODEL FIREFLY III EXTENDED PERFORMANCE RELEASE DEVICE TABLE OF CONTENTS INTRODUCTION

More information

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

CM-RQE70 PIR REQUEST TO EXIT DETECTOR Door Activation Devices CM-RQE70 PIR REQUEST TO EXIT DETECTOR THIS PACKAGE INCLUDES (1) Wiring Harness (2) #6 x 3/4" Screws (2) 3/16" Wall Plugs (6) Wire Nuts (2) 's BP7175 1. GENERAL DESCRIPTION Camden

More information

2409/2900. Fire Guard

2409/2900. Fire Guard 2409/2900 Fire Guard Table of Contents Features and Additional Fire Opening Devices... 1 2409 Single-Point Hold Open Applications and Mounting Details... 2 2409 Track Assemblies, Arms and Components...

More information

Conventional Releasing Control Panel

Conventional Releasing Control Panel s Data Sheet Fire Safety Products Conventional Releasing Control Panel Pre-Action Deluge Agent-Releasing Fire System Model TXR-320 Remote configurable Up to two (2) hazard areas Operable with the following:

More information

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions 1 PACKAGE CONTENTS Wiring Harness 6 Wire Nuts #6 x 3/4 Screws s BP7175 3/16 Wall Plugs Section 1: General Description Camden CM-RQE-70 Request-to-Exit

More information

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation PS6 SERIES Power Supplies PS6 SERIES Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation and Specifications Manual ISDPS6_SERIES 08121590 PCN15016 R05/15GR

More information

RMS/RPX Reader. User Manual

RMS/RPX Reader. User Manual RMS/RPX Reader User Manual Copyright Disclaimer Trademarks and patents Intended use FCC compliance Copyright 2005, GE Security Inc. All rights reserved. This document may not be copied or otherwise reproduced,

More information

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL MADE IN THE U.S.A. U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION SERIAL NUMBER The Cookson Company FIREFLY II PLUS Time Delay Release

More information

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE Fire Door Release MODEL AR-D2 MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D2 GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

Upgrade Your Solution: Mechanical to Electrical

Upgrade Your Solution: Mechanical to Electrical Upgrade Your Solution: Mechanical to Electrical 2 Upgrading from mechanical to electrified hardware doesn t have to be difficult. Adams Rite makes it easy by offering products for aluminum and glass storefronts

More information

2408/2900. Fire Guard

2408/2900. Fire Guard 2408/2900 Fire Guard Table of Contents Features and Additional Fire Opening Devices... 1 2408 Single-Point Hold Open Applications and Mounting Details... 2 2408 Track Assemblies, Arms and Components...

More information

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01 PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Warnings and Notices WARNING - To reduce the risk of fire or electric shock, do not expose this product

More information

Rack Mount Series Installation Guide

Rack Mount Series Installation Guide Rack Mount Series Installation Guide Models Include: Maximal1RHV Maximal1RV - 12VDC @ 4 amp or 24VDC @ 3 amp. - 12VDC @ 4 amp or 24VDC @ 3 amp. - Eight (8) Fuse Protected Outputs. - Sixteen (16) Fuse Protected

More information

DS160/161 Request To Exit PIR sensors Installation Instructions

DS160/161 Request To Exit PIR sensors Installation Instructions DS160/161 Request To Exit PIR sensors Installation Instructions 1.0 Description The DS160/161 is a passive-infrared (PIR) detector designed for request to exit (REX) interior applications. It is UL Listed

More information

SECTION LOW VOLTAGE LIGHTING CONTROLS

SECTION LOW VOLTAGE LIGHTING CONTROLS SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

Monarch Electrified Series

Monarch Electrified Series Monarch Electrified Series THE FALCON DIFFERENCE S A F E T Y, S E C U R I T Y A N D U N C O M P R O M I S I N G V A L U E At Falcon, we know that every product you sell not only has to meet local building

More information

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide Introduction This is the Interlogix RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Instructions for models RCR-REX-W,

More information

8600 EMR SERIES. INSPK NO Rev.06/ INS NO. GENERAL DESCRIPTION

8600 EMR SERIES. INSPK NO Rev.06/ INS NO. GENERAL DESCRIPTION 00 EMR SERIES GENERAL DESCRIPTION Each 00 EMR series unit contains a door closer, hold open electromagnet and smoke detector. The unit can be used as a single installation or as a series of singles powered

More information

Honeywell ENERGY SAVINGS KIT

Honeywell ENERGY SAVINGS KIT ENERGY SAVINGS KIT 1. Application The Honeywell Energy Savings Kit reduces energy consumption by sending a dry contact signal to a Honeywell thermostat to change its set-point (increase in cooling mode)

More information

UNC100 Integra Manual

UNC100 Integra Manual UNC100 Integra Manual New Generation Building Security July 30, 2014 V1.2 Copyright Notice Copyright 1995-2014 by All rights reserved Worldwide. Printed in Canada. This publication has been provided pursuant

More information

I/O ZONE 560/583 AND OPERATION MANUAL

I/O ZONE 560/583 AND OPERATION MANUAL UPM I I/O ZONE 560/583 INSTALLATION AND OPERATION MANUAL 1 UNIT PROTECTION MODULE HARDWARE OPERATION IMPORTANT: This manual is for UPM board part numbers 8733 800 259. See controller label as shown in

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

Duct smoke housings, 4-wire D341/D341P and D342/D342P

Duct smoke housings, 4-wire D341/D341P and D342/D342P Duct smoke housings, 4-wire D341/D341P and D342/D342P en Installation manual Duct smoke housings, 4-wire Notices en 3 1 Notices These instructions cover the installation of the D341/D342 Duct smoke housings

More information

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature AutoTest VSR (VSR-AT) (EU) Features Assembled in USA 0-30 second field replaceable electronic retard Two SPDT (Form C) switch contacts Weatherproof Easy to read wire terminal designations Easy to read

More information

4700 SERIES PLC INTERLOCK CONTROLLER

4700 SERIES PLC INTERLOCK CONTROLLER 4700 SERIES PLC INTERLOCK CONTROLLER The 4700 series PLC interlock controller is a self-contained, cost effective controller for operating door interlock and mantrap systems of up to 4 doors or for many

More information

UNIVERSITY OF ROCHESTER DESIGN STANDARDS FEBRUARY 2005MARCH 2007

UNIVERSITY OF ROCHESTER DESIGN STANDARDS FEBRUARY 2005MARCH 2007 SECTION 08710 - DOOR HARDWARE 1.1 SUMMARY A. Door hardware required for swinging doors. No pocket or folding doors permitted at U of R. 1.2 SUBMITTALS A. Hardware Schedule: To be coordinated with doors,

More information

SECURITRON MODEL EXD EXIT DELAY SYSTEMS INSTALLATION AND OPERATING INSTRUCTIONS 1. DESCRIPTION

SECURITRON MODEL EXD EXIT DELAY SYSTEMS INSTALLATION AND OPERATING INSTRUCTIONS 1. DESCRIPTION PN# h 500-13350 Page 1 Rev. A.3, 7/03 SECURITRON MODEL EXD EXIT DELAY SYSTEMS INSTALLATION AND OPERATING INSTRUCTIONS 1. DESCRIPTION Securitron s EXD series is modular delayed exit locking systems intended

More information

SMARTWALK DEMENTIA WANDERING SYSTEM

SMARTWALK DEMENTIA WANDERING SYSTEM A division of NESS CORPORATION PTY LTD SMARTWALK DEMENTIA WANDERING SYSTEM SWD Door Responder SWD Resonator SWD-PET (Sold Separately) SWD-PET-BAND (Sold Separately) INSTALLATION MANUAL 1. CONTENTS 1. CONTENTS...1

More information

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804 #4202 2 amp #4204 4 amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL 4202/4MA, Rev. E 0804 4202/4204 Power Supply Fused 115 V Input Low Battery Indicator DC Output Adjustable 0.7 to 3.7 Volts from nominal

More information

Rev D 3/20/17

Rev D 3/20/17 Rev D 3/20/17 Installation and Operating Instructions ADAEZ Wireless Interface Module (WIM) Note Changes or modifications not expressly approved by the party responsible for compliance could void the user

More information

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE SAFE A N D SECURE Cornell 100 Elmwood Ave. Crestwood Industrial Park Mountaintop, PA 18707 Tel 800.233.8366 Fax 800.526.0841 Email: cornell@cornelliron.com O W N E R S M A N U A L M O D E L F I R E G A

More information

Access Power Controllers with Power Supplies

Access Power Controllers with Power Supplies Access Power Controllers with Power Supplies Installation Guide Models Include: Maximal11FD - Power Supply 1: 12VDC @ 3.3A or 24VDC @ 3.6A. - Power Supply 2: 12VDC @ 3.3A or 24VDC @ 3.6A. - Sixteen (16)

More information

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

THE SS90 SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL S S S S S S S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED U 99Y9 RESET L RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA) INSTRUCTION MANUAL AlarmGard Chain Operator (Model FCA) & AlarmGard Crank Operator (Model FKA) WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within

More information

Power Supplies. Overview

Power Supplies. Overview Power Supplies Overview Access control provides enhanced security, audit trails, and custom credentials. The power supply is necessary to make the entire system operational. Power supplies offer accurate

More information

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE Cookson 100 Elmwood Avenue Crestwood Industrial Park Mountaintop, PA 18707 Phone: 800-233-8366 Fax: 800-526-0841 CornellCookson.com O W N E R S M A N U A L M O D E L S F I R E G A R D M C F I R E G A R

More information

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL TABLE OF CONTENTS Product Overview... 2 Operation... 3 Installation... 5 Troubleshooting... 9 Ordering Information, Warranty and Service...10

More information

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR SECTION 08734 COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES A. Overhead

More information

Accessories. Desk Top Controls

Accessories. Desk Top Controls Accessories Desk Top Controls 15-2 15-1 15-3 15-2-3 DTMO-1 DTMA-1 Under Desk Top Mounting The SDC 15 series switch controls are mounted on the underside of a desk for remote door control. They may be connected

More information

Public Safety DAS Annunciator Panel

Public Safety DAS Annunciator Panel Public Safety DAS Annunciator Panel 120 VAC Models: 1221-A, 1221-B, 1221-C Revision D 91117 48 VDC Models: 1221-A-48, 1221-B-48, 1221-C-48 24 VDC Models: 1221A-24, 1221-B-24, 1221-C-24 CAUTION: (Read This

More information

Power Transfer Devices. Access Control Accessories. How To Order. How to Order

Power Transfer Devices. Access Control Accessories. How To Order. How to Order Power Transfer Devices Door Cord (TSB-C) Simplest and most economical solution for power transfer Standard with Touch Sense Bar and MGL but may also be purchased separately Consists of an 18 [460mm] or

More information

Pump-Up Controller MODEL 4062

Pump-Up Controller MODEL 4062 Pump-Up Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4062 Pump-Up

More information