SCAN200E USER S MANUAL

Size: px
Start display at page:

Download "SCAN200E USER S MANUAL"

Transcription

1 SCAN200E USER S MANUAL Code No rev. 1.4

2 Code No Rev. 1.4 Page 2/16 SCAN200E User s Manual Foreword This manual is for SCAN200E Controller running software version 2.03 or later. We recommend that the manual is stored near to the main unit. Information of the unit is stored at the customer database. Correct maintenance and spare parts will be arranged based on controller serial number and exact details about the fault case. Contact DETECTOR Oy maintenance department regarding service, calibration and spare parts: DETECTOR OY Telekatu Turku Tel Fax detector@detector.fi

3 SCAN200E User s Manual Code No Rev.1.4 Page 3/16 CONTENTS SCAN200E Gas Detection Controller... 4 Introduction... 4 Passwords... 4 Main Menu... 5 Bar Graph... 5 Numeric Numeric SETTINGS... 7 Linearization... 7 Date and time... 7 Alarm limits... 7 Sensor settings... 9 General settings Relay settings Passwords Sample rate Communication Save to USB Read from USB EVENTS Trends Alarm events Service Inhibiting of Alarms and Channels... 15

4 Code No Rev. 1.4 Page 4/16 SCAN200E User s Manual SCAN200E GAS DETECTION CONTROLLER Introduction SCAN200E Gas Detection Controller is designed to implement real time gas detection of large industrial sites by using one controller. The Controller can accommodate up to 64 gas detectors and 128 relays depending on the number of modules installed. Every Input Module holds 8 inputs and every Relay Module holds 8 relays. The first logical Relay Module has following reservations, relays 1 3 are general alarm class relays and relay 4 is generally the fault relay. Modules communicate using RS-485 up to a distance of 1 km. Galvanic isolators will be used between Main Controller and Sub Controllers when needed. The Main Controller has backlit LCD display to represent concentrations, trend graphs and alarm history. Normal alarm classes, 1/C, 2/B, 3/A (or 0/D = only relay control without an alarm) and relays are assigned for each of the three alarm levels for each channel. An additional alarm class of 4/AA will activate class 3/A alarm and class relay. Additional relay control (a selected relay from 5 to 128) for class 4/AA alarm will function as a relay (latching relay) which controls the function of a solenoid valve. This relay control can be acknowledged only after alarm has ceased. There is no dedicated class relay for class 4/AA alarm. In case of fault the yellow fault LED will be lit and relay number 4 activates. Alarm and fault cases are stored in the alarm history. Passwords The Controller has 2 replaceable passwords, password 1 and password 2. Factory defaults for these passwords are found on the original inspection sheet. Password 1 gives access to ALARM INHIBIT, relay test, alarm levels, date and time. Password 2 gives in addition access to other parameters and password change Image 1, User Interface

5 SCAN200E User s Manual Code No Rev.1.4 Page 5/16 Main Menu Press menu The bar graph is the default display. Main menu shows by pressing menu button. The desired function is accessed by pressing the relevant arrow key next to the display. The previous level is accessed by pressing menu button. BARGRAPH SETTINGS NUMERIC 1 EVENTS NUMERIC 2 FI - SUOMI Image 2, Main menu Bar Graph Press menu - BARGRAPH Bar Graph display shows simultaneously the signals from 8 channels (one input module). Next or previous page can be selected by pressing PREV. or NEXT. The channel numbers are shown at the bottom of the bars. The scaling of the bar graph is set at Settings PREV. 23:05 NEXT Image 3, Bar Graph: alarm limit 1 exceeded on channel 2, alarm limit 2 exceeded on channels 1 and 4, alarm limit 3 exceeded on channel 8. Other channels have no alarms.

6 Code No Rev. 1.4 Page 6/16 SCAN200E User s Manual Numeric 1 Press menu NUMERIC 1 Large numbers indicating the concentrations and followed by triggered alarm limits with Roman numerals, 1 input module = 8 channels per page. Next or previous page can be selected by pressing PREV. or NEXT I III II I PREV. 23:05 NEXT Image 4, Numeric 1 Numeric 2 Press menu NUMERIC 2 Detailed per channel information including channel names, concentrations, units and triggered alarm limits with Roman numerals, 1 input module = 8 channels per page. Next or previous page can be selected by pressing PREV. or NEXT. 01 POINT ID PPM I 02 POINT ID. 0.0 %XYZ 03 POINT ID PPM I II III 04 POINT ID. 0.0 %XYZ 05 POINT ID. 0.0 %XYZ 06 POINT ID. 0.0 %XYZ 07 POINT ID. 0.0 %XYZ 08 POINT ID. 0.0 %XYZ PREV. 23:05 NEXT Image 5, Numeric 2

7 SCAN200E User s Manual Code No Rev.1.4 Page 7/16 SETTINGS Press menu - SETTINGS LINEARIZATION CHANNELS DATE AND TIME GENERAL ALARM LIMITS FI - SUOMI Image 6, SETTINGS Linearization Press menu SETTINGS LINEARIZATION Password 2 Type in linearization table number and press enter. Type in linearization points and corresponding values. Linearization points (input) shall increase while corresponding values (output) may increase or decrease. Table ends when input value is smaller than previous one. After typing in all values needed, press enter and STORE. Date and time Press menu SETTINGS DATE AND TIME Password 1 Type in date and time and press enter. Daylight saving time needs to be changed manually. Alarm limits Press menu SETTINGS ALARM LIMITS Password 1 Type in channel number and press enter. Cursor moves on to the alarm limit direction of limit 1. Choose the direction by typing 0, 1 or 2. Alarm limit direction 0 = limit not in use 1 = upper limit 2 = lower limit After selecting the direction, press enter. Cursor moves on to the concentration. Type in the value using numeric keys and press enter. Cursor moves on to the alarm class. Choose the alarm class by typing 0 (D), 1 (C), 2 (B), 3 (A) or 4 (AA) and press enter.

8 Code No Rev. 1.4 Page 8/16 SCAN200E User s Manual Alarm classes 0 (D) = No alarm, limit assigned relay control only. 1 (C) = Class I alarm, relay 1 and limit assigned relays activate, indicates a warning. 2 (B) = Class II alarm, relay 2 and limit assigned relays activate, indicates an alarm 3 (A) = Class III alarm, relay 3 and limit assigned relays activate, indicates a high alarm with screen and optional SMS messages. 4 (AA) = Class III alarm and acknowledge-after-alarm functionality for assigned relay for critical controls. Type in control relays, press enter. 000 = no control relay. Relay 004 is common fault relay. Type in alarm delay and press enter. Type in alarm hysteresis / dead band and press enter. After typing in and accepting all values with enter for 3 limits, save the changes by selecting STORE with the display corner button. By selecting COPY you can copy the settings of currently selected channel subsequent channels. E.g. channel 5 alarm settings can be copied to channels from 6 to 10. LEFT CURSOR RIGHT CHANNEL 01 CHANNEL ID LIMIT 1 0 OFF VALUE CLASS C RELAYS DELAY HYSTER LIMIT 2 0 OFF VALUE CLASS B RELAYS DELAY HYSTER LIMIT 3 0 OFF VALUE CLASS A RELAYS DELAY HYSTER STORE COPY Image 7, Alarm limits

9 SCAN200E User s Manual Code No Rev.1.4 Page 9/16 Sensor settings Press menu SETTINGS SENSORS Password2 Type in channel number and press enter. Type in channel name. Move the cursor using LEFT and RIGHT. Press enter to accept the name. Type in sensor type (0 to 9) and press enter. Sensor types 00 = OFF / not in use (channel power supply stays on) 01 = Current signal 0 20 ma 02 = Current signal 4 20 ma (fault limit 3,7 ma) 03 = Voltage signal 0 1 V 04 = OLCT20/50 (4 20 ma, fault limit 2,5 ma) 05 to 09 = Linearization tables, see Settings - Linearization Type in the sensor scaling low value with desired decimal point location and press enter. The place of decimal point is set here and change of decimal point location affects alarm limit values accordingly, please check all values after decimal point location change. Type in the sensor scaling high point and press enter. Type in the unit (e.g. PPM) and press enter. Maximum amount of characters is 4. Bar and trend graph displays may have a different scaling from the measure scaling above. This way you can observe a certain range of interest. Type in bar and trend graph scaling low point and press enter. Type in bar and trend graph scaling high point and press enter. LEFT CURSOR RIGHT CHANNEL 01 POINT ID. SENSOR: 02 (4-20 ma) SENSOR SCALING: LOW HI PPM BARGRAPH AND TREND SCALING: 0%: %: STORE COPY Image 8, Channel settings

10 Code No Rev. 1.4 Page 10/16 SCAN200E User s Manual Example, 4 20 ma Oxygen sensor The sensor is calibrated to the range %, but you want to monitor the oxygen concentration between 15 and 22% in the bar graph and the trend displays. In this case you will set 15% for showing the 0% at the display and 22% for showing 100% at the display. If signal falls below the scaling, 0 % is shown. If the concentration is higher than the set 100% display, the maximum display is 100%. The real values can be checked on the numeral displays. All settings are coming into force by pressing the STORE button. You can also here use the COPY function, whereby you can copy the displayed settings to following channels. General settings Press menu SETTINGS GENERAL Password2 RELAY SETUP SAMPLE RATE PASSWORDS COMMUNICATION READ FROM USB SAVE TO USB Image 9, General settings Relay settings Press menu SETTINGS GENERAL Password 2 RELAY SETUP Type in the relay table number (1 to 8) and press enter. Switch between fields by pressing enter. Type in relay functions as follows First number 1 = NC (normally connected) / 0 = NO (normally open) Seconds number 0 = NR (follows limit) / 1 = R (resettable) After typing in all settings needed, press enter and STORE.

11 SCAN200E User s Manual Code No Rev.1.4 Page 11/16 Passwords Press menu SETTINGS GENERAL Password 2 PASSWORDS Type in passwords and press enter. Sample rate Press menu SETTINGS GENERAL Password 2 SAMPLE RATE Type in sample rate / minute (1 to 4). See Trends. Communication Press menu SETTINGS GENERAL Password 2 COMMUNICATION Type in RS232 serial mode and press enter. 0= service 1= alarm SMS using GSM modem (option) 2= Not in use Choice 1 will show the following screen after pressing enter. LEFT CURSOR RIGHT GAS ALARM GSM1 : GSM2 : GSM2 : Image 10, Alarm SMS phone numbers Type in gas alarm message and press enter. Type in phone numbers using international format. Use zeros for a slot not in use. After typing in all the numbers, press enter. Alarm messages will be sent in case of limit 3, class 3/A or 4/AA alarms only! Alarm SMS contains the information of triggered channel. Acknowledge the alarm by calling to the sender number within 5 minutes and let it ring couple of times. There will be no answer. In case of no acknowledge within 5 minutes, another SMS will be sent to the second number. This will continue until all numbers have been notified once.

12 Code No Rev. 1.4 Page 12/16 SCAN200E User s Manual Save to USB Press menu SETTINGS GENERAL Password 2 SAVE TO USB Save controller settings to USB flash drive. Take a backup each time settings have been changed. Use an empty flash disk formatted into FAT32. Transfer time is 30 to 60 seconds depending on flash drive speed. Indicator light next to the USB connector will blink with a variable speed. Controller notifies the user upon successful transfer. Following settings are not included in the file: Modbus settings Date and time For your own convenience, send the file to us at detector@detector.fi to be archived. It will facilitate technical support and maintenance. Read from USB Press menu SETTINGS GENERAL Password 2 READ FROM USB Read controller settings from USB flash disk. Take a backup each time settings have been changed. Use empty flash drive formatted into FAT32. Transfer time is 30 to 60 seconds depending on flash drive speed. Indicator light next to the USB connector will blink with a variable speed. Controller notifies the user upon successful transfer. New settings will apply immediately without further prompt! Following settings are not included in the file: Modbus settings Date and time USB copy to another controller Controller settings can be copied from a controller to another controller by changing the serial number of the settings file from the source controller and saving the file for the target controller with the target serial number and file name. See Save to USB to save the settings for the source controller to a USB flash drive. Connect the USB drive to a PC and edit the text file in a text editor, for example Notepad. Locate the serial number row by searching the file with the serial number for the source controller, for example , a row with following syntax is found: #001N C Replace the serial number portion with the serial number for the target controller, i.e , and the last two characters 6C with?? characters, result: #001N ?? Save the file with the new serial number as file name CFG. The new file has the target serial number as a parameter in the file and as file name. See Read from USB to use the file in the target controller. Please verify correct settings after reading the settings in to the target controller.

13 EVENTS Press menu - EVENTS SCAN200E User s Manual Code No Rev.1.4 Page 13/16 TREND 45 min TREND 6 h. ALARM EVENTS TREND 2 d. SERVICE ALARM INHIB. Trends Image 11, History Press menu HISTORY TREND Type in channel number and press enter. Buffer contains 180 samples for each view. Trend view contains information about 45 minutes to 8 days depending on sample rate. See Sample rate for more information. Trend scaling is identical to bar graph scaling, see Sensor settings for more information TREND 45 m. CHANNEL 01 POINT ID %XYZ Image 12, Trend graph

14 Code No Rev. 1.4 Page 14/16 SCAN200E User s Manual Alarm events Press menu HISTORY ALARM EVENTS The list shows 3 alarm events per page starting from the newest one. Press PREVIOUS to access earlier events. Each event contains channel number, date and time and event type. Triggered alarm event also contains limit number and measure value at the time of alarm. Event types: SENSOR FAULT Sensor failure, caused by drift, signal overload or cabling defect. SENSOR RESUME Sensor failure or defect has been corrected. CHANNEL INHIBIT Channel disabled. LIMIT X* HI ALARM Signal has exceeded the alarm limit. LIMIT X* LOW ALARM Signal has fallen below the alarm limit. LIMIT X* NORMALIZED Signal has returned to normal range. COMMUNICATION FAULT Communications problem, module number indicated. COMMUNICATION RESUMED Communications returned back to normal. * X stands for the alarm limit ALARM HISTORY CHANNEL LIMIT 1 OFF PPM CHANNEL SENSOR FAULT CHANNEL LIMIT 3 HI ALARM PPM PREVIOUS NEXT Service Image 13, Alarm history Press menu HISTORY SERVICE Password 1 To test the relays, type in the desired relay unit number (choose the unit from the installed ones 1, 2, 3 or 16) and press enter. All relays at the relay unit will be activated. Stop the test by pressing enter.

15 Inhibiting of Alarms and Channels SCAN200E User s Manual Code No Press menu HISTORY ALARMS INHIB. or CHANNEL INH. Password 1 Rev.1.4 Page 15/16 This function prevents fault LED blinks and alarms triggering and deactivation from being in force. It is used e.g. when servicing the gas detection system. Fault LED blinks as indication. The function concerns also Class 0 relay controls. Press RESUME ALARMS to restore normal operation. New alarm inhibition period can be started at all times, also when alarm inhibition is already activated. INHIBIT ALL 2 h ALARM INH. xxh RESUME ALARMS CHANNEL INH. SMS 3. GSM Image 14, Alarm inhibits All alarm inhibits for 2 hours Prevents alarms from triggering and deactivating. Alarm inhibition for 1 to 240 hours on selected channels Prevents alarms from triggering and deactivating on selected channels. Time left is shown at NUMERIC1 view. PREVIOUS CHANNEL NEXT 1=NORMAL, 0=INHIBITION STORE Image 15, Channel specific alarm inhibitions Type in the amount of hours, 1 to 240 and press enter. Move cursor by pressing enter or NEXT. Save the settings by pressing enter and STORE.

16 Code No Rev. 1.4 Page 16/16 SCAN200E User s Manual CONTROLLER FUNCTION AT ALARM SITUATIONS Class 0 When a set alarm limit is passed, the set control relay activates. The relay will be restored when the signals from all concerning channels are back to normal again. The set delay and dead band affect the relay functions. Note that several channels can activate the same relay. At this class, no information of the relay activities is stored in the alarm history. Class 1 and 2 Control and class relays are activated, LED class indicators are lit. The information of the relay activities is stored in the alarm history. Class 3 In addition to class 1 and 2, also a buzzer is activated and an alarm message is displayed. The class relay and buzzer functions are deactivated by pressing ACK. The LED class indicator and the control relay follow the signal (they are not deactivated by pressing the ACK button). Class 4 Class 4 activates also class 3. Class 4 does not have a dedicated class relay. The alarm limit, which activated class 4, control relay is active until acknowledged from the dedicated acknowledge button, after concentration has returned to normal. This is known as the acknowledge-after-alarm. See ALARM LIMITS. Failure When an error in the sensor connections or another malfunction occurs, the FAULTindicator is lit, the fault relay activates and the buzzer beeps. A message will be displayed. The buzzer can be deactivated by pressing ACK. The fault relay and the fault indicator functions are restored when the failure is corrected.

SCAN20 Series Gas Detection Controller

SCAN20 Series Gas Detection Controller SCAN20 Series Gas Detection Controller USER S MANUAL Code Number 2071 1022 SCAN20 USER S MANUAL Code no. 2071 1022 Page 1/14 Foreword This manual is made for SCAN20 Controllers equipped with the software

More information

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy. Installation manual detector and controller Code no. 20711062 Page 1/30 CONTENTS Controller... 2 Function of the Relays... 2 Gas Detectors... 2 Cabling... 4 Mechanical Installation of the gas detectors...

More information

Refrigerated air dryers

Refrigerated air dryers Refrigerated air dryers OPERATING AND MAINTENANCE MANUAL Original instructions 38178800319 OPERATING AND MAINTENANCE MANUAL - Contents 1 CONTENTS CONTENTS... 1 Chapter 1 IDRY ELECTRONIC CONTROLLER...

More information

Laptop / PC Programming Manual

Laptop / PC Programming Manual Laptop / PC Programming Manual Doc. # Fire PC Program rev B 01.07 This Document is property of Evax Systems, Inc. The Evax Fire Solutions Programmer Components 2 1.0 System Setup 4 1.1 Interface Setup

More information

GLD-30 Gas Leak Detector

GLD-30 Gas Leak Detector GLD-30 Gas Leak Detector Installation, Operation & Maintenance General: The Archer Instruments GLD-30 is an ambient air monitor, used to detect the presence of a target gas (or gases) and to alert operators

More information

Gas Detection System TOX ALARM DG2000-Garage

Gas Detection System TOX ALARM DG2000-Garage Gas Detection System TOX ALARM DG2000-Garage Gas Detection System 32 independent programmable channels 2 programmable alarm levels for each gas = up to 6 for each channel LCD alphanumeric display of gas

More information

Pioneer-R16 Gas Monitor Operator s Manual

Pioneer-R16 Gas Monitor Operator s Manual Pioneer-R16 Gas Monitor Operator s Manual Edition 7/2/97 RKI INSTRUMENTS, INC RKI Instruments, Inc. 33248 Central Ave, Union City, CA 94587 (510) 441-5656 Chapter 1: Description About the Pioneer-R16 Gas

More information

Fire Control Panel FS5100

Fire Control Panel FS5100 Fire Control Panel FS5100 INSTRUCTION MANUAL Revision 6/02.11 Contents 1. Introduction... 5 2. Terminology... 5 3. Function... 7 4. Technical data... 7 4.1. Modules... 7 4.1.1. Type of modules... 7 4.1.2.

More information

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Revision 6/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features. CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse

More information

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA HART Field Device Specification Meridian wiredhart 4320 Goldmine Rd. Monroe, NC 28110 USA HART is a registered trademark of the HART Communication Foundation TABLE OF CONTENTS 1. Introduction...5 1.1 Scope...5

More information

AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL

AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL M 890-00279 rev. 14 K 895-00004 rev. 00 Manufacturer: Viatron Electronics 5200, Armand-Frappier St-Hubert (Quebec) Canada J3Z 1G5 WARNINGS The warranty can be void

More information

rvm4c Installation Guide Remote Video Module

rvm4c Installation Guide Remote Video Module rvm4c EN Installation Guide Remote Video Module rvm4c Installation Guide Installation Diagrams EN 2 Installation Diagrams for the Transmitting Unit rvm4c Installation Guide Basic Hardware Installation

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

Halton SAFE / 7.14 user guide and installation instructions

Halton SAFE / 7.14 user guide and installation instructions Halton SAFE / 7.14 user guide and installation instructions VERIFIED SOLUTIONS BY H A LTO N Enabling Wellbeing Table of contents 1 System description 3 2 User Accounts 4 3 Main menu 7 3.1 Main menu - Change

More information

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Revision 4/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort USER MANUAL S203 Controller for three circuits - control for 2 heating circuits - 1 domestic hot water control Saving energy, creating comfort This user manual consists of two parts. Issues that are intended

More information

Section 9 System Operation

Section 9 System Operation Section 9 System Operation Operation of the control panel is simple. Menus guide you step-by-step through operations. This section of the manual is an overview of the operation menus. Please read this

More information

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460) Operating Manual TS400 Test Station for Microtector II Series (G450/G460) GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)2 31 / 5 64 00 0 FAX +49 / (0)2 31 /

More information

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once. Table of Content 1.1General Description----------------------------------------------------------------------2 2.2System Setup-----------------------------------------------------------------------------3

More information

SC-F3G User Manual 1.0

SC-F3G User Manual 1.0 SC-F3G User Manual 1.0 Table of Contents 1. Introduction... 3 2. Functions... 3 3. Features... 3 4. Package Contents... 3 5. Device Configuration... 4 6. Status LED signals... 5 7. Before You Start...

More information

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Operations Manual TS400. Test Station for G450/G460 Gas Detector TS400 Test Station for G450/G460 Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.goodforgas.com GfG Products for Increased Safety Congratulations

More information

HERCULES 6 GRAPHICS SYSTEM

HERCULES 6 GRAPHICS SYSTEM HERCULES 6 GRAPHICS SYSTEM USER MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273 Web: www.protec.co.uk

More information

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Operations Manual TS400. Test Station for G450/G460 Gas Detector TS400 Test Station for G450/G460 Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.gfg-inc.com GfG Products for Increased Safety Congratulations

More information

Ontech GSM 9040/50. Reference Manual English -1 -

Ontech GSM 9040/50. Reference Manual English -1 - Ontech GSM 9040/50 Reference Manual English -1 - Content Welcome... 5 This manual... 5 Text styles... 5 Support... 5 Disclaimer... 5 Overview... 6 Accessories... 6 External temperature sensor 9901... 7

More information

3D_ISS. Integrated Software System. User Guide Manual

3D_ISS. Integrated Software System. User Guide Manual 3D Digital Design & Development LTD 58/60 Edward Road Tribec House New Barnet EN4 8AZ 020 8440 7060 3D_ISS Integrated Software System User Guide Manual Copyright 2014 3D Digital Design and Development

More information

COMMUNICATOR ET08 / ET081

COMMUNICATOR ET08 / ET081 COMMUNICATOR ET08 / ET081 User Manual v1.2 Safety instructions Please read and follow these safety guidelines in order to maintain safety of operators and people around: GSM communicator ET08 / ET081 (further

More information

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

La Marche Manufacturing Company   Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual La Marche Manufacturing Company www.lamarchemfg.com Option 46 Series Digital Combined Accessory Package Installation and Operation Manual This manual is subject to change without notice. You may obtain

More information

ALARM SYSTEM USER S MANUAL Rev

ALARM SYSTEM USER S MANUAL Rev ALARM SYSTEM USER S MANUAL Rev.06 890-00011 Manufacturer: Viatron Electronics 3514 1st Street, St-Hubert (Quebec) Canada J3Y 8Y5 WARNINGS the warranty can be void if the Agri-Alert 2400 is used in a manner

More information

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual Syncro AS Analogue Addressable Fire Control Panel User Manual Man-1100 Issue 02 Nov. 2008 Index Section Page 1. Introduction...3 2. Safety...3 3. Panel Controls...4 3.1 Access Level 1...4 3.2 Access Level

More information

User Manual. Dryer Controller M720

User Manual. Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009

More information

No part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic,

No part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic, No part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic, mechanical, by photocopying, recording or in any other manner

More information

FLOW CONTROLLER TYPE S/601

FLOW CONTROLLER TYPE S/601 Checked Version Release date QA V4.2.6 F1 F2 EN 26.01.2012 Manual FLOW CONTROL FLOW CONTROLLER TYPE S/601 MODELS F1 AND F2 INTRODUCTION Thank you for using the S/601 flow and batch control series. This

More information

with internal sensor (channel 1) with an external sensor (channel 2) A-Editor software, Professional AK20 version (not for version AK4)

with internal sensor (channel 1) with an external sensor (channel 2) A-Editor software, Professional AK20 version (not for version AK4) Examples of use Example Creating an SMS-based alarm with confirmation A project file must first be created using the A-Editor software. This project file is then stored in the alarm modem. The alarm modem

More information

OUMAN EH-800 Heating controller USER MANUAL

OUMAN EH-800 Heating controller USER MANUAL OUMAN EH-800 Heating controller USER MANUAL 1 EH-800 is a heating controller for private homes and business facilities having heating systems with circulating water. An extension unit can be obtained as

More information

CT224 Setup Tutorial

CT224 Setup Tutorial CT224 Setup Tutorial Table of Contents 1. Introduction 2. Configuring Controller for Operation A. Example 1 Over Temp Operation with Hysteresis @ 5º F. B. Example 2 Under Temp Operation with Hysteresis

More information

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63 Fire Extinguishing Control Panel FS5200Е INSTRUCTION MANUAL Revision 8/01.17 Instruction Manual Page 1 1. 2. 3. 4. 4.1. 4.2. 4.2.1. 4.2.2. 4.2.3. 4.2.4. 4.2.5. 4.2.6. 4.2.7. 4.2.8. 4.2.9. 4.2.10. 4.2.11.

More information

BURGLAR ALARM PANEL BS-468

BURGLAR ALARM PANEL BS-468 BURGLAR ALARM PANEL BS-468 Contents 1. Description... 3 2. Instructions for the user... 4 2.1Basic operations... 4 Complete system.... 4 Split system.... 4 2.2 Armed system indication... 5 2.3 Advanced

More information

Tech Data Sheet D01662GB0_Esgraf 4.1 and Configuration Server 30/2011 2/(5)

Tech Data Sheet D01662GB0_Esgraf 4.1 and Configuration Server 30/2011 2/(5) Tech Data Sheet D01662GB1_Esgraf 4.1 and Configuration Server 30/2011 1/(5) Esgraf 4.1 graphical user interface, configuration server and fire detectors contamination monitoring Esgraf 4.1 ESGRAF is a

More information

IRIS Touch Firmware Enhancements and Additions from Version to Version

IRIS Touch Firmware Enhancements and Additions from Version to Version Overview IRIS Touch Firmware Enhancements and Additions from Version 1.14.3 to Version 1.19.1 This document details enhancements to the feature set of the IRIS Touch from firmware Version 1.14.3 to Version

More information

D3D Wi-Fi GSM Smart Alarm System -User Manual

D3D Wi-Fi GSM Smart Alarm System -User Manual D3D Wi-Fi GSM Smart Alarm System -User Manual D3D Wi-Fi / GSM Smart Alarm system (Model : D10). Please read all instructions carefully & follow steps for easy home installation. 1 P a g e D3D Wi-Fi / GSM

More information

Dryer Controller M720

Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,

More information

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System MOBILE CALL GSM Alarm System GSM Alarm System System disarmed 11/26/2013 User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. CONTENTS

More information

EXPERT TRI-STAR. Temperature controller. User s Manual

EXPERT TRI-STAR. Temperature controller. User s Manual Temperature controller r s Manual WARNINGS The warranty can be void if this product is used in a manner not specified by the manufacturer. Every effort has been made to ensure that this manual is complete,

More information

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number Worldwide Supplier of Safety Solutions GfG Instrumentation 1194 Oak Valley Drive #20 Phone: 734-769-0573 Fax: 734-769-1888 E-Mail: info@gfg-inc.com Internet: www.gfg-inc.com GMA 301 Operation Manual Part

More information

LevelSET S GSM Functionalities Instructions for Commissioning and Use

LevelSET S GSM Functionalities Instructions for Commissioning and Use Labkotec Oy Myllyhaantie 6 FI-33960 Pirkkala, Finland Tel: +358 29 006 260 Fax: +358 29 006 1260 22.10.2010 Internet: www.labkotec.fi LevelSET S GSM Functionalities Instructions for Commissioning and Use

More information

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm External Dimensions: B = 600 mm D = 630 mm H = 2000 mm Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm Capacity: 328 l Temperaturerange: -15 C to -30 C Housing galvanized sheet steel with white

More information

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12 AUTOMATION P R O D U C T S GROUP, INC. Operator s Manual RST-5000 Series Web Enabled Input Module Rev. A2, 1/12 Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com RST-5000

More information

PERMACONN PM1030 Includes DI300. Installation Manual

PERMACONN PM1030 Includes DI300. Installation Manual PERMACONN PM1030 Includes DI300 Installation Manual Radio Data Comms Unit 5/20-30 Stubbs Street Silverwater NSW 2128 Telephone: 02 9352 1777 Facsimile: 02 9352 1700 Introduction The PERMACONN system provides

More information

System. For a better understanding of this product, please read this user manual thoroughly before using it.

System. For a better understanding of this product, please read this user manual thoroughly before using it. GSM Alarm System User s Manual For a better understanding of this product, please read this user manual thoroughly before using it. Chapter 1. Features Chapter 2. Control Panel Introduction Chapter 3.

More information

DiaLog Elite. Quick Reference Guide. Remote Monitoring, Control and. Alarm Notification System. # Enter. 1 Prog. 2 Run. 5 SpkrPh. Ack. Arm.

DiaLog Elite. Quick Reference Guide. Remote Monitoring, Control and. Alarm Notification System. # Enter. 1 Prog. 2 Run. 5 SpkrPh. Ack. Arm. DiaLog Elite 1 Prog Remote Monitoring, Control and 2 Run Alarm Notification System 5 SpkrPh 0 Status # Enter Quick Reference Guide Ack Clear Arm Reset Disarm Bksp Home Antx, inc. 2008 RUN Mode Commands

More information

EasyTronic III MANUAL SERVICE

EasyTronic III MANUAL SERVICE rev.6 EasyTronic III MANUAL SERVICE General characteristics: Power supply 24 Vac ±15% Max consumption at 24Vac 300mA Relay outputs 6 Maximum relay current 8 A res. Serial standard RS232 2 Serial standard

More information

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS.  A4741 / Rev.1 DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS User Manual and Menu Map A4741 / Rev.1 www.entes.com.tr ATTENTION -Disconnect all power before connecting the device. -Don t remove

More information

SMS GSM Alarm Messenger

SMS GSM Alarm Messenger SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up

More information

aura-t TP536/EU ventilation systems

aura-t TP536/EU ventilation systems EN aura-t TP536/EU Product Manual HRV controller ventilation systems Warnings, Safety information and Guidance Important Information Read instructions fully before the installing this appliance. 1. This

More information

Oxygen (O2) Single-Point Gas Detection System

Oxygen (O2) Single-Point Gas Detection System Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity

More information

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08 Beacon 200 Gas Monitor Operator s Manual Part Number: 71-2102RK Released: 6/6/08 Table of Contents Chapter 1: Introduction.................................................3 Overview.............................................................3

More information

Mark 25 Ultrapure Water Conductivity Analyzer

Mark 25 Ultrapure Water Conductivity Analyzer Martek Instruments, Inc. Mark 25 Ultrapure Water Conductivity Analyzer Instruction Manual WARRANTY POLICY Unless otherwise stated, MARTEK INSTRUMENTS, INC. warrants this equipment to be free from defects

More information

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual ZX1e ZX2e ZX5e Document No. 996-130 Issue 01 user manual MORLEY-IAS ZX2E/ZX5E Fire Alarm Control Panels Table of Contents 1 INTRODUCTION... 4 1.1 NOTICE... 4 1.2 WARNINGS AND CAUTIONS... 4 1.3 NATIONAL

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary

More information

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1 ViewMatrix Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels Version: 2.0 Revision: 0.1 CONTENTS 1. Introduction...3 2. Keyboard...5 2.1 POWER indication - Normal Operation...5

More information

USER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY

USER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY + USER S MANUAL 1.0 HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY SECURITY KEYPAD WITH PROXIMITY TAGS PREVENTION OF WATER DAMAGES

More information

Section 8 System Operation

Section 8 System Operation Section 8 System Operation Operation of the control panel is simple. Menus guide you step-by-step through operations. This section of the manual is an overview of the operation menus. Please read this

More information

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System MOBILE CALL GSM Alarm System USER S MANUAL System disarmed 00/00/00 00:00 ARM STAY CALL 1 2 3 4 5 6 7 8 9 Power Set Signal Alarm SOS ESC 0 ENTER Profile For a better understanding of this product, please

More information

Rotem One Touch. User Manual PRELIMINARY DOCUMENT. Ag/MIS/UmGB /18 Rev 1.0 P/N:

Rotem One Touch. User Manual PRELIMINARY DOCUMENT. Ag/MIS/UmGB /18 Rev 1.0 P/N: User Manual Rotem One Touch Rotem One Touch Ag/MIS/UmGB-2603-06/18 Rev 1.0 P/N: 110741 Rotem One Touch User Manual Revision: N.1.0 of 02.2018 Product Software: 7.14 This manual for use and maintenance

More information

Watchguard WGAP864 User Manual

Watchguard WGAP864 User Manual Watchguard WGAP864 User Manual v1.0 Issued September 2016 1 2 Table of Contents Glossary... 5 1. Introduction to your Watchguard WGAP864... 6 2. Before Operating your Alarm System... 6 3. Understanding

More information

User Guide IM/SM3000 EN Rev. L. SM3000 Multipoint Videographic Recorder

User Guide IM/SM3000 EN Rev. L. SM3000 Multipoint Videographic Recorder User Guide IM/SM3000 EN Rev. L SM3000 The Company We are an established world force in the design and manufacture of measurement products for industrial process control, flow measurement, gas and liquid

More information

JA-63 Profi User manual

JA-63 Profi User manual JA-63 Profi User manual Contents: 1 Limited warranty... 2 2 Indicators... 3 3 Controlling the system... 4 3.1 Arming... 5 3.2 Disarming... 6 3.3 Panic Alarm... 6 3.4 To stop ALARM... 6 3.5 Home arming...

More information

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm. E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0E FL0E FL0E mm mm 0 mm DESCRIPTION The LT FL0 Series is part of the Fire Alarm Aspiration

More information

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01 ProTalk Expander Operating Manual Model B1292 July 28, 2009 Rev. 1.01 TABLE OF CONTENTS 1. Introduction... 1 2. Installation... 2 2.1 Wiring Diagram... 3 3. Operations... 4 4. Programming (B1225 Mode)...

More information

ECO601 OPERATING INSTRUCTIONS ME04

ECO601 OPERATING INSTRUCTIONS ME04 RAK 72.2 9.11.2010 1 2 3 4 5 6 7 8 9 0 # ECO601 OPERATING INSTRUCTIONS ME04 PRESENTATION The ECO601 is intended for the simple control and surveillance of premises. This device can be controlled locally

More information

MODEL 4300-PG CENTRAL ACCESS PANEL FOR EC-GOLD TRANSMITTERS. User Manual

MODEL 4300-PG CENTRAL ACCESS PANEL FOR EC-GOLD TRANSMITTERS. User Manual MODEL 4300-PG CENTRAL ACCESS PANEL FOR EC-GOLD TRANSMITTERS User Manual Technical Support Continental North America Toll Free 1-(800) 387-9487 Ph: +1 (905) 829-2418 Fx: +1 (905) 829-4701 A Product of Arjay

More information

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand 2 Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd Operating Guide Proudly Designed and Manufactured in New Zealand 1 CONTENTS Page No. INTRODUCTION 3 About your Alarm 3 OPERATING YOUR

More information

REPEATER FS5200R INSTRUCTION MANUAL

REPEATER FS5200R INSTRUCTION MANUAL REPEATER FS5200R INSTRUCTION MANUAL Instruction Manual Page1 CONTENTS 1. Introduction... 3 2. Function... 3 3. Technical data... 3 4. Contents of delivery... 4 5. General information... 5 6. Duty Mode...

More information

ECO N DATE DESCRIPTION OF CHANGE CHG

ECO N DATE DESCRIPTION OF CHANGE CHG Model Number: M21E-24-DIN Description: The product is a loop powered device which controls an unsupervised dual pole output channel suitable to manage 24VAC loads. The M21E-24-DIN is micro-controller operated,

More information

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone! Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone! GSM SMS Controller DCS-130 User Manual Ver 1.20 Date Issued: 14-9-2010

More information

Measuring Recording Online Monitoring Regulation Alarming

Measuring Recording Online Monitoring Regulation Alarming Measuring Recording Online Monitoring Regulation Alarming Temperature Humidity CO 2 Dew point Atmospheric pressure Analog signals Two-state inputs Pulses Battery operated recorders and printers Economical

More information

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! USER GUIDE English IMPORTANT PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal. Contents

More information

Installation Manual Tracker 221

Installation Manual Tracker 221 Installation Manual Tracker 221 KSR KUEBLER AG Im Kohlstatterfeld 17 D-69439 Zwingenberg / Germany www.ksr-kuebler.com Contents About this Installation Manual...4 Description Tracker 220-series...4 Installing

More information

1. Functions of GPS locator ETLOC-30S 3

1. Functions of GPS locator ETLOC-30S 3 Contents 1. Functions of GPS locator ETLOC-30S 3 1.1 Direct view of the vehicle position on the map 3 1.2 Vehicle security 3 1.2.1 Vehicle protection 3 1.2.1.1 GPS protection 3 1.2.1.2 GPS higher level

More information

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual BS-316 Gas detection control panel up to 16 inputs Installation operation manual Page 1 from 21 Contents 1 Operation instructions--------------------------------------------------------------------------------------------------------------------3

More information

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528] Installation- & Operation manual [Dok. id: mi-303gb_180528] Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction and control output MF-PFA ver 3.x NOTE! Read through the entire manual

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

Temperature Controller CC24-7 UNIBOX USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

Temperature Controller CC24-7 UNIBOX USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517) 3 4 Temperature Controller USER S MANUAL Aerotech, Inc. FORM: QM1386 4215 Legion Dr. Mason, MI 48854-1036 USA October 2010 Ph. (517) 676-7070 Fax (517) 676-7078 FOR CUSTOMER USE Enter the serial number

More information

3 User s settings. 3.3 Internal clock setting

3 User s settings. 3.3 Internal clock setting 2.9 Subsystem arming In a large building a sub control panel can be enrolled to the JA-63. The subsystem reports all alarms and failures to the main system. The installer can program if the systems will

More information

Trident User s Manual

Trident User s Manual Labkotec Oy Myllyhaantie 6 33960 Pirkkala FINLAND Tel. +358 (0)29 006 260 18.05.2017 Fax +358 (0)29 006 1260 Internet: www.labkotec.fi 34 pages Trident Copyright 2017 Labkotec Oy 1/34 TABLE OF CONTENTS

More information

SECTION 1 (Page 2) Introduction, standard accessories and mounting specifications.

SECTION 1 (Page 2) Introduction, standard accessories and mounting specifications. HGM300 / RDM800 Refrigerant Monitoring System Instruction 3015-4149 Installation & Operation Mini Manual Rev. 5 November 2004 SECTION 1 (Page 2) Introduction, standard accessories and mounting specifications.

More information

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1 Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User

More information

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using. V1.0 Smart Home Alarm System User Manual APP download via QR Code scanning Please read the manual carefully before using. Content FUNCTION PROFILE 2 THE SCHEMATIC GRAPH OF HOST 3 PROCESS OF BOOTING 6 OPERATION

More information

Contents. Glossary

Contents. Glossary Contents Glossary ------------------------------------------------------------------------------------------------------ 6 1. Introduction to the IDS 1632 -------------------------------------------------------------

More information

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING Tempered Water Logic Control OPERATION l TROUBLE SHOOTING English For MPE Multiple Chiller Units Control Panel TEMPERED WATER SYSTEMS L-2199 Rev. 20080223 Revision: L-2199 20101104 *** IMPORTANT NOTICE

More information

Operation Manual. Programmable Logic Controller

Operation Manual. Programmable Logic Controller Operation Manual Programmable Logic Controller Part No. 9983-0000-E01 / January 2018 OPERATION MANUAL TABLE OF CONTENTS CUSTOMER SERVICE 3 CONTACT INFORMATION 3 ORDER INFORMATION 3 INTRODUCTION 4 THE PROCESS

More information

PolyGard Controller LGC/LG2-04. Multi-Point Controller Serial Number S00 User Manual Preliminary Version. August 11, 2006

PolyGard Controller LGC/LG2-04. Multi-Point Controller Serial Number S00 User Manual Preliminary Version. August 11, 2006 PolyGard Controller LGC/LG2-04 Multi-Point Controller Serial Number S00 User Manual Preliminary Version August 11, 2006 January 04, 2016 Revision Specifications subject to change without notice. USA 160104

More information

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions Worldwide upplier of Gas Detection olutions GfG Instrumentation 1194 Oak Valley Drive, uite 20 Ann Arbor, MI 48108 800-959-0329 tel 734-769-1888 fax email: info@gfg-inc.com GMA4100-DP Control Panel Operation

More information

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated External Dimensions: B = 600 mm D = 650 mm (at -30 C/-40 C: 760 mm) H = 1640 mm (at -30 C/-40 C: 1720mm) Internal Dimensions: B = 500 mm D = 500 mm H = 890 mm Capacity: 300 l Temperaturerange: Optional:

More information

PRODUCT BULLETIN. Rev. A Monitoring Station offering PN Rev. B as a direct replacement. OVERVIEW / DESCRIPTION

PRODUCT BULLETIN. Rev. A Monitoring Station offering PN Rev. B as a direct replacement. OVERVIEW / DESCRIPTION PRODUCT BULLETIN ISSUE/DATE: March 28, 2008 rev A BULLETIN NUMBER: AQ032808 SUBJECT: Monitoring Station PRODUCT LINE: Aquafine UV Equipment TOPIC: REVISION TO THE 41114-1 MONITORING STATION OVERVIEW /

More information

GSM RFID VOICE Alarm System

GSM RFID VOICE Alarm System GSM RFID VOICE Alarm System User s Manual For a better understanding of this product, please read this user manual thoroughly before using it. CONTENTS [Function Instruction] [Control Panel] Control Panel

More information

EC2-5x2 Series Condensing Unit Controllers

EC2-5x2 Series Condensing Unit Controllers Technical Data The EC2-Series form a new generation of electronic controllers for refrigeration and air conditioning. The controllers combine in the small industry standard housing maximum functionality

More information

M3092 Programmer. User s Manual. M3096B-33 E Copyright 2017 SELCO

M3092 Programmer. User s Manual. M3096B-33 E Copyright 2017 SELCO User s Manual Copyright 2017 SELCO SELCO Betonvej 11 - DK-4000 Roskilde Denmark Phone: 45 7026 1122 - Fax: 45 7026 2522 e-mail: selco@selco.com www.selco.com Table of contents 1 INTRODUCTION...4 2 SOFTWARE

More information